Attachment C - PHO Summary - PHO-1-25--Z-12-22-7.pdf

City of Phoenix — Formal (2025-05-21)

View PDF Meeting page

Extracted text (via pymupdf) 17786 characters
REPORT OF PLANNING HEARING OFFICER ACTION 
Adam Stranieri, Principal Planner, Hearing Officer  
Teresa Garcia, Planner I, Assisting  
April 16, 2025 
ITEM NO: 3 
DISTRICT NO. 7 
SUBJECT: 
Application #: 
PHO-1-25--Z-12-22-7 
Location: 
Northwest corner of 47th Avenue and Baseline Road 
Zoning: 
R1-8 
Acreage: 
14.07 
Request: 
1)
Request to modify Stipulation 2 regarding the review of
conceptual elevations
Applicant: 
Melissa Vasquez, Ashton Woods Arizona 
Owner: 
Ashton Woods Arizona 
Representative: 
Melissa Vasquez, Ashton Woods Arizona 
ACTIONS:  
Planning Hearing Officer Recommendation: The Planning Hearing Officer 
recommended approval with modifications. 
Village Planning Committee (VPC) Recommendation: The Laveen Village 
Planning Committee heard this request on April 14, 2025 and recommended 
approval with additional stipulations, by a vote of 10-0. 
DISCUSSION: 
Melissa Vasquez, representative with Ashton Woods Arizona, gave an overview 
of the request for review by the Planning Hearing Officer per Stipulation 2 and 
the conceptual elevations. She explained that the proposal included three 
different elevation styles: Spanish Craftsman, Farmhouse, and Modern Desert. 
She provided details regarding the building materials and architectural details on 
these elevations including siding, building materials, driveway length, window 
design, garages, EV connections, loft options, patio options, and other details.  
Mr. Stranieri noted that elevations were not provided during the original rezoning 
hearing and the stipulation in question was created to facilitate review of 
elevations when provided, which was the purpose of this hearing. He stated that 
the review requirement should be updated to a requirement for general 
conformance to the elevations. 
ATTACHMENT C

Planning Hearing Officer Summary of April 16, 2025 
Application PHO-1-25--Z-12-22-7 
Page 2 
 
He stated that Stipulation 2.a regarding architectural detailing should be retained 
and noted that many of the elevations meet this requirement while some 
elevations may require additional detailing, including some of the side elevations. 
He confirmed with the applicant that the project would be subject to single-family 
design review and noted that some aspects of the stipulations are already 
required by this process.  
He stated that the majority of elevations meet Stipulation 2.b regarding building 
materials as well and should be retained.  
He addressed Stipulation 2.c regarding front elevations and noted that the 
Laveen VPC recommendation included additional requirements for architectural 
detailing and limited use of this elevation. He asked the applicant if they had any 
comments. Ms. Vasquez responded that they are open to the recommendation 
and clarified that one request was to alter the window soffits. Mr. Stranieri stated 
that he was inclined to add the exemption for Spanish elevations from the non-
stucco requirement. He stated he was not inclined to add the VPC recommended 
limitation on the percentage of homes within the subdivision that could use the 
Spanish elevation as it would be extremely difficult to implement as it would 
require tracking of all permits within the subdivision for use when any individual 
permit was applied for, which is not something that the City does. He stated he 
was not inclined to add the additional requirement for architectural details on the 
Spanish elevations as detailing is already addressed in Stipulation 2.a. He noted 
that the details discussed at the Laveen VPC could already be implemented in 
that stipulation and he would like to avoid confusion or redundancy between 
these stipulations.  
He addressed Stipulation 2.d regarding garage door detailing and noted that it 
should be retained.  
He addressed Stipulation 2.e regarding front porches. He noted that he had 
difficulty in determining how the individual elevations complied with the 
requirements as the floor plans were not clearly tied to the individual elevations. 
He noted that retaining the stipulation in its entirety should resolve that 
uncertainty. He noted that he would remove the language tying this to the Zoning 
Ordinance itself as the requirement stood in the stipulation itself. 
He addressed the Laveen VPC recommendation for an additional stipulation 
regarding 18-inch overhangs and stated he had no concern adding this 
stipulation.  
He addressed the Laveen VPC recommendation for an additional stipulation 
regarding windows on street facing elevations and stated he had no concern 
adding this stipulation. 
He addressed the Laveen VPC recommendation regarding roofline variety. He 
stated that he was not inclined to add this stipulation as the project was already 
subject to single-family design review which requires diversity by providing a 
minimum of three roof shapes, materials, and colors. He also suggested that the

Planning Hearing Officer Summary of April 16, 2025 
Application PHO-1-25--Z-12-22-7 
Page 3 
 
single-family design review requirement would allow greater diversity in shape 
beyond the three identified in the VPC stipulation.  
Ms. Vasquez noted that in prior projects she had worked on in the Laveen area 
she had been stipulated to 18-inch overhangs on front elevations only which had 
allowed lower price points for buyers. She asked if that could be considered and 
noted that one of Laveen’s concerns in this regard was water intrusion. She 
suggested consideration of gutters, noting that in these prior projects she had not 
experienced water issues, and expressed a preference for 12-inch overhangs. 
Mr. Stranieri researched one prior project noted by Ms. Vasquez but found the 
stipulation consistent with the Laveen VPC recommendation in this case. He 
noted that he felt the Laveen recommendation in this regard was about both 
aesthetics and functionality and he was inclined to adopt the stipulation as 
recommended. 
Stephanie Hurd noted that she was a member of the Laveen VPC and that the 
additional stipulation regarding 18-inch overhangs was consistent with many prior 
recommendations from this VPC. She stated that the Laveen VPC had 
considered recommending removing the Spanish elevation from the set entirely 
but ultimately decided that this elevation would allow a lower price option. 
However, she stated the additional recommendations regarding this elevation 
were intended to make it more consistent with the level of detail in the other 
designs.  
Ms. Hurd asked for clarification regarding the prior discussion on the Spanish 
elevations. Mr. Stranieri reiterated the earlier discussion to adopt the VPC 
recommendation exempting the Spanish elevation from the stucco requirement, 
not adopt the restriction on the percentage of homes to use the Spanish 
elevation due to enforcement difficulty, and not adopt the additional architectural 
elements as this is addressed in Stipulation 2.a.  
Ms. Hurd asked for clarification regarding whether the Spanish elevation would 
be exempt from Stipulation 2.a and asked Ms. Vasquez for her understanding. 
Ms. Vasquez replied that in her VPC presentation she had made suggestions 
aimed at embellishing the Spanish elevations and agreed that these 
recommendations could be accomplished with Stipulation 2.a. Ms. Hurd stated 
she understood that the Spanish elevation was not exempt. Mr. Stranieri stated 
that the Laveen VPC’s recommendation for specific details could be 
accomplished with the existing stipulation.  
Mr. Stranieri reiterated earlier comments regarding the Laveen VPC 
recommendation on rooflines. Ms. Hurd noted that the intent was to improve 
architectural diversity.  
Mr. Stranieri approved the request with modifications.

Planning Hearing Officer Summary of April 16, 2025 
Application PHO-1-25--Z-12-22-7 
Page 4 
 
FINDINGS: 
 
1) The applicant submitted conceptual elevations for review and approval per 
Stipulation 2. This stipulation has now been complied with and it is 
recommended to be modified to require general conformance, retain 
conditions from the review requirement, and incorporate new 
recommendations from the Laveen VPC. 
 
2) The applicant provided 18 elevations in a range of architectural styles 
including Craftsman, Farmhouse, Spanish, and Modern Desert. Elevations 
include both single and two story options. The elevations include various 
architectural details and embellishments, building materials, and garage 
door treatments. Included floor plans show a variety of front porch 
designs. It is recommended to retain Stipulations 2.a through 2.e to 
ensure these details remain in subsequent submittals, including through 
the required Single-Family Design Review process. A minor modification 
is recommended to Stipulation 2.e to remove a reference to the Zoning 
Ordinance which is unnecessary. 
 
3) The Laveen VPC recommended four additional stipulations. Stipulations 
regarding enhanced overhangs and window quantity on street-facing 
elevations are recommended to be added as additional stipulations. A 
stipulation regarding Spanish elevations is recommended to be added in 
part to exempt these elevations from Stipulation 2.c regarding the 
minimum percentage of non-stucco material. However, it is not 
recommended to add the VPC’s recommended restriction on the total 
number of Spanish elevations permitted to be constructed within the 
community as this may be difficult to enforce through the permitting 
process. Additionally, the VPC recommendation for additional features for 
Spanish elevations can be addressed through existing Stipulation 2.a. 
Finally, the VPC’s recommended stipulation regarding rooflines can be 
addressed through existing requirements in the Single-Family Design 
Review process which requires provision of a minimum three alternative 
roof materials, shapes, and/or colors. 
 
STIPULATIONS: 
 
1. 
The development shall be in general conformance to the site plan date 
stamped May 4, 2022, with specific regard to the following element, as 
approved by the Planning and Development Department. 
 
 
a. 
A minimum of 16% of the gross site area shall be retained as open 
space. 
 
2. 
The conceptual elevations shall be reviewed and approved by the 
Planning Hearing Officer through the public hearing process for

Planning Hearing Officer Summary of April 16, 2025 
Application PHO-1-25--Z-12-22-7 
Page 5 
 
stipulation modification prior to approval of the Single-Family Design 
Review Diversity Exhibit, with specific regard to the inclusion of the below 
elements. This is legislative review for conceptual purposes only. Specific 
development standards and requirements will be determined by the 
Planning Hearing Officer and the Planning and Development 
Department. 
 
THE DEVELOPMENT SHALL BE IN GENERAL CONFORMANCE WITH 
THE ELEVATIONS DATE STAMPED MARCH 13, 2025, AS MODIFIED 
BY THE FOLLOWING STIPULATIONS, AND AS APPROVED BY THE 
PLANNING AND DEVELOPMENT DEPARTMENT: 
 
 
a. 
All elevations shall incorporate a minimum of three of the following 
architectural embellishments and detailing: textural changes, 
pilasters, offsets, recesses, variation in window size and location, 
and/or overhang canopies. 
 
 
b. 
All elevations shall incorporate a minimum of three of the following 
building materials: native stone, burnt adobe, textured brick, wood 
(when shaded by overhangs or deep recesses), slump block, 
ceramic tile (matte finish), stucco, and/or exposed aggregate 
concrete. 
 
 
c. 
The front elevations shall consist of a minimum 25% non-stucco 
accent material, EXCEPT SPANISH ELEVATIONS. 
 
 
d. 
All garage doors shall have decorative embellishments such as 
window panels, added materials surrounding the door, and/or 
trellises. 
 
 
e. 
A minimum of 75% of the standard elevations provided shall include 
patios and/or covered porches in the front yard at a minimum of 60 
square feet in area and a depth of at least six feet, and clearly 
separated from the front yard with fencing, subject to the Phoenix 
Zoning Ordinance. 
 
 
F. MINIMUM 18-INCH OVERHANG ON ALL FOUR SIDES, EXCEPT 
SPANISH ELEVATIONS. 
 
 
G. ANY STREET FACING SIDE OF A TWO STORY HOME MUST 
HAVE A MINIMUM OF 2 WINDOWS OR OTHER VISUAL 
ELEMENTS TO BREAK UP BUILDING MASSING. 
 
3. 
Lots 7, 8, 9 and 10 along Baseline Road shall be limited to 26 feet, as 
approved by the Planning and Development Department.

Planning Hearing Officer Summary of April 16, 2025 
Application PHO-1-25--Z-12-22-7 
Page 6 
 
4. 
No more than two two-story homes shall be built adjacent to one another 
along 47th Avenue, as approved by the Planning and Development 
Department. 
 
5. 
Homes shall have minimum 5-foot-wide side yard setbacks. 
 
6. 
The developer shall install wiring within homes for electric vehicle 
capabilities. 
 
7. 
Required landscape setbacks shall be planted with minimum 50% 2-inch 
caliper and 50% 3-inch caliper large canopy drought-tolerant trees, 20 
feet on center or in equivalent groupings, with 5-gallon shrubs per tree, 
as approved by the Planning and Development Department. 
 
8. 
The entry drives shall incorporate enhanced landscaping on both sides, 
planted with a variety of at least three plant materials, as approved by the 
Planning and Development Department. 
 
9. 
The developer shall dedicate a 30-foot-wide multi-use trail easement 
(MUTE) along the north side of Baseline Road and construct a minimum 
10-foot-wide multi-use trail (MUT) within the easement in accordance 
with the MAG supplement detail and as approved by the Planning and 
Development Department. Where conflicts or restrictions exist, the 
developer shall work with the Site Planning section on an alternate 
design through the technical appeal process. 
 
10. 
A minimum 22-foot setback shall be provided to the front of garages, 
measured from the back of the sidewalk, for each home in the 
development, as approved by the Planning and Development 
Department. 
 
11. 
The developer shall dedicate 30 feet of right-of-way along the west side 
of 47th Avenue, as approved by the Planning and Development 
Department. 
 
12. 
The developer shall complete the west side of 47th Avenue to include a 
minimum 5-foot-wide detached sidewalk and minimum 8-foot-wide 
landscape area located between the back of curb and sidewalk to match 
the northern limit of the site, as approved by the Planning and 
Development Department. 
 
13. 
The developer shall replenish the existing streetscape along Baseline 
Road, as approved by the Planning and Development Department. 
 
14. 
Where sidewalks are detached along 47th Avenue, Baseline Road, and 
internal to the site, the landscape area located between the sidewalk and

Planning Hearing Officer Summary of April 16, 2025 
Application PHO-1-25--Z-12-22-7 
Page 7 
 
back of curb shall be planted to the following standards, as approved by 
the Planning and Development Department. 
 
 
a. 
Minimum 3-inch caliper, large canopy, single-trunk, shade trees 
placed a minimum of 25 feet on center or in equivalent groupings to 
provide a minimum of 75% shade on adjacent sidewalks. 
 
 
b. 
Drought tolerant shrubs and vegetative groundcovers with a 
maximum mature height of 24 inches to provide a minimum of 75% 
live coverage at maturity. 
 
 
c. 
Where utility conflicts arise, the developer shall work with the 
Planning and Development on an alternative design solution 
consistent with a pedestrian environment. 
 
15. 
The developer shall construct a clearly defined and shaded pedestrian 
pathway providing access to the multi-use-trail along Baseline Road, as 
approved by the Planning and Development Department. 
 
16. 
Traffic calming measures shall be installed within the development, as 
approved by the Street Transportation Department. 
 
17. 
The developer shall construct all streets within and adjacent to the 
development with paving, curb, gutter, sidewalk, curb ramps, streetlights, 
median islands, landscaping and other incidentals, as per plans 
approved by the Planning and Development Department. All 
improvements shall comply with all ADA accessibility standards. 
 
18. 
The developer shall rebuild the bus stop pad along westbound Baseline 
Road according to P1260 and P1258, unless stated otherwise by the 
Public Transit Department. 
 
19. 
If determined necessary by the Phoenix Archaeology Office, the 
applicant shall conduct Phase I data testing and submit an 
archaeological survey report of the development area for review and 
approval by the City Archaeologist prior to clearing and grubbing, 
landscape salvage, and/or grading approval. 
 
20. 
If Phase I data testing is required, and if, upon review of the results from 
the Phase I data testing, the City Archaeologist, in consultation with a 
qualified archaeologist, determines such data recovery excavations are 
necessary, the applicant shall conduct Phase II archaeological data 
recovery excavations. 
 
21. 
In the event archaeological materials are encountered during 
construction, the developer shall immediately cease all ground-disturbing

Planning Hearing Officer Summary of April 16, 2025 
Application PHO-1-25--Z-12-22-7 
Page 8 
 
activities within a 33-foot radius of the discovery, notify the City 
Archaeologist, and allow time for the Archaeology Office to properly 
assess the materials. 
 
Upon request, this publication will be made available within a reasonable length 
of time through appropriate auxiliary aids or services to accommodate an 
individual with a disability. This publication may be made available through the 
following auxiliary aids or services: large print, Braille, audiotape or computer 
diskette. To request a reasonable accommodation, please contact Saneeya Mir 
at saneeya.mir@phoenix.gov or (602) 686-6461 or TTY: 7-1-1.