Attachment B - Staff Report - Z-23-22-8.pdf
Extracted text (via pymupdf)
39886 characters
Staff Report: Z-23-22-8 June 3, 2022 Camelback East Village Planning Committee Meeting Date June 7, 2022 Planning Commission Hearing Date August 4, 2022 Request From: R1-6 (0.36 acres) Request To: R-4 (0.36 acres) Proposed Use Multifamily residential Location Northwest corner of 35th Street and Culver Street Owner First Mill, LLC Applicant/Representative Artin Knadijan Staff Recommendation Approval, subject to stipulations General Plan Conformity General Plan Land Use Map Designation Residential 15+ dwelling units per acre Street Map Classification 35th Street Local 30-foot west half street Culver Street Local 15-foot north half street CONNECT PEOPLE AND PLACES CORE VALUE; OPPORTUNITY SITES; LAND USE PRINCIPLE: Support reasonable levels of increased intensity, respectful of local conditions and surrounding neighborhoods. The proposal will create a new multifamily development in an area where similar developments exist. The proposed site plan and elevations also depict a development that is compatible in scale and character to the surrounding neighborhood. Attachment B Staff Report: Z-23-22-8 June 3, 2022 Page 2 of 12 CELEBRATE OUR DIVERSE COMMUNITIES AND NEIGHBORHOODS CORE VALUE; CLEAN NEIGHBORHOODS; LAND USE PRINCIPLE: Facilitate the acquisition of vacant, underutilized and blighted parcels for appropriate redevelopment, compatible with the adjacent neighborhood character and adopted area plans. The request proposes to develop a multifamily project on a relatively larger lot compared to others in the surrounding area. There is a single home on the lot currently, and the proposed multifamily development will allow the development of additional dwelling units on the site. As stipulated, the development will provide enhanced screening in the form of landscaping and a larger building setback, thus ensuring that the project will be compatible with the adjacent single-family parcel to the west. BUILD THE SUSTAINABLE DESERT CITY CORE VALUE; TREES AND SHADE; DESIGN PRINCIPLE: Integrate trees and shade into the design of new development and redevelopment projects throughout Phoenix. As stipulated, the proposal will provide a detached sidewalk along 35th Street, shade trees along the sidewalk, and shade the parking lot with the new proposed building to provide thermal comfort and shade for pedestrians and residents entering and exiting their vehicles. Applicable Plans, Overlays, and Initiatives Housing Phoenix Plan – See Background Item No. 6. Tree and Shade Master Plan – See Background Item No. 7. Complete Streets Guiding Principles – See Background Item No. 8. Comprehensive Bicycle Master Plan – See Background Item No. 9. Zero Waste PHX – See Background Item No. 10. Surrounding Land Uses/Zoning Land Use Zoning On Site Single-family residence R1-6 North Multifamily residences R-4 South (across Culver Street) Gateway Elementary School PAD-13 (Approved R-3A) and R1-6 Staff Report: Z-23-22-8 June 3, 2022 Page 3 of 12 East (across 35th Street) Multifamily residences R-3A West Single-family residence R1-6 R-4 – Multifamily Residence District (Subdivision Development Option) Standards Requirements Provisions on the Proposed Site Plan Gross Acreage - 0.36 Total Number of Units 10 maximum 8 units (Met) Dwelling Unit density (units/gross acre) 29 maximum 22.22 (Met) Lot Coverage 50% Maximum 43% (Met) Maximum Building Height 3 stories or 40 feet 3 stories, 30 feet (Met) Building Setbacks Front: 20 feet Rear: 15 feet Sides: 10 feet and 3 feet Front: 20 feet (Met) Rear: 33 feet (Met) Side (north): 10 feet (Met) Side (south): 10 feet (Met) Landscape Setbacks Front: 20 feet Sides and Rear: 5 feet each Front: 20 feet (Met) Side (north): 10 feet (Met) Side (south): 10 feet (Met) Rear: 5 feet Common Area/ open space 5.0% 5.0% (Met) Parking Requirements 1.5 spaces per 1 and 2- bedroom unit and additional unreserved parking at a rate of 0.5 spaces per 1 and 2- bedroom unit: Eight 2-bedroom units proposed in addition to a recycling container 15 spaces required 15 (Met) Staff Report: Z-23-22-8 June 3, 2022 Page 4 of 12 Background/Issues/Analysis SUBJECT SITE 1. This request is to rezone 0.36 acres located at the northwest corner of 35th Street and Culver Street from R1-6 (Single-Family Residence District) to R-4 (Multifamily Residence District) to allow a multifamily residential development. The proposal is consistent with the surrounding multifamily zoning to the north, east, and south of the site. 2. The subject site as well as the surrounding area is designated Residential 15+ dwelling units per acre on the General Plan Land Use Map. The proposed density is consistent with this designation and compatible with Land Use Map designations in the surrounding area. Zoning Sketch Map, Source: City of Phoenix Planning and Development Department General Plan Land Use Map, Source: City of Phoenix Planning and Development Department Staff Report: Z-23-22-8 June 3, 2022 Page 5 of 12 EXISTING CONDITIONS & SURROUNDING ZONING 3. The subject site is currently developed with a single-family residence and is zoned R1-6 (Single-Family Residence District). The request proposes to rezone the site to R-4 (Multifamily Residence District), which is consistent with the existing zoning of the property to the north. There are multifamily residences to the north and east, across 35th Street, which are zoned R-3A (Multifamily Residence District) and R-4. To the west, is a single-family residence zoned R1-6 while an elementary school is located south of the site and is zoned R1-6 and PAD-13 (Planned Area Development), approved R-3A. PROPOSAL 4. The conceptual site plan proposes an eight-unit multifamily development with a height of three stories and 30 feet. While all of the surrounding structures in the area are two stories, this development proposes a maximum height of 30 feet that is consistent with the maximum height permitted for structures in single-family residential districts. Thus, the proposed development is sensitive to the scale of surrounding uses. The site plan also depicts a single vehicular entry point off of 35th Street, which leads into a parking lot located under the proposed building. An amenity area is proposed along the western edge of the development consisting of a gazebo, table and benches. Staff does not recommend general conformance to the proposed site plan provided by the applicant as additional detail on the open space area calculation is required and the placement of the trash or recycling facility might require variances. Variances undergo the Zoning Adjustment hearing process following the rezoning process. However, to maintain the privacy and compatibility with the adjacent single-family home west of the subject site, staff recommends an enhanced building setback of no less than 33 feet to be provided along the western property line in addition to 2-inch caliper large canopy trees. This is addressed in Stipulation Nos. 2 and 3. Staff Report: Z-23-22-8 June 3, 2022 Page 6 of 12 5. The conceptual building elevations depict modern architectural features that are unique to the surrounding area. The elevations depict a maximum building height of three stories and 30 feet to the top of the flat roofline. The variety of building materials (stucco, metal, lap siding, veneer), metal canopies, and color palette accents are consistent with a high-quality development. This proposal will be consistent with the scale and character of the surrounding neighborhood and, as such, staff is recommending general conformance to the elevations submitted, per Stipulation No. 1. Conceptual Site Plan, Source: Aakaii Staff Report: Z-23-22-8 June 3, 2022 Page 7 of 12 PLANS, OVERLAYS, AND INITIATIVES 6. Housing Phoenix Plan In June 2020, the Phoenix City Council approved the Housing Phoenix Plan. This Plan contains policy initiatives for the development and preservation of housing with a vision of creating a stronger and more vibrant Phoenix through increased housing options for residents at all income levels and family sizes. Phoenix’s rapid population growth and housing underproduction has led to a need for over 163,000 new housing units. Current shortages of housing supply relative to demand are a primary reason why housing costs are increasing. The proposed development supports the Plan’s goal of preserving or creating 50,000 housing units by 2030 by providing an opportunity for multifamily residential units in an area envisioned by the General Plan Land Use Map for multifamily uses. 7. Tree and Shade Master Plan The Tree and Shade Master Plan has a goal of treating the urban forest as infrastructure to ensure that trees are an integral part of the city’s planning and development process. By investing in trees and the urban forest, the city can reduce its carbon footprint, decrease energy costs, reduce storm water runoff, increase biodiversity, address the urban heat island effect, clean the air, and increase property values. In addition, trees can help to create walkable streets and vibrant pedestrian places. Staff is recommending enhanced tree plantings along the 35th Street frontage to provide minimum 75 percent shade on the sidewalk and along the western perimeter landscape setbacks to help reduce the urban heat island effect created by the parking lot surface. These recommendations are addressed in Stipulation Nos. 3 and 4. Conceptual Building Elevations, Source: Aakaii Staff Report: Z-23-22-8 June 3, 2022 Page 8 of 12 8. Complete Streets Guiding Principles In 2014, the City of Phoenix City Council adopted the Complete Streets Guiding Principles. The principles are intended to promote improvements that provide an accessible, safe, connected transportation system to include all modes, such as bicycles, pedestrians, transit, and vehicles. In addition to the enhanced landscaping standards, staff is recommending that the sidewalk along 35th Street be detached. This is addressed in Stipulation No. 4. 9. Comprehensive Bicycle Master Plan The City of Phoenix adopted the Comprehensive Bicycle Master Plan in 2014 to guide the development of its bikeway system and supportive infrastructure. The Comprehensive Bicycle Master Plan supports options for both short- and long-term bicycle parking as a means of promoting bicyclist traffic to a variety of destinations. As stipulated, the development will provide a minimum of six bicycle parking spaces. This is addressed in Stipulation No. 5. 10. Zero Waste PHX The City of Phoenix is committed to its waste diversion efforts and has set a goal to become a zero-waste city, as part of the city’s overall 2050 Environmental Sustainability Goals. One of the ways Phoenix can achieve this is to improve and Section 716 of the Phoenix Zoning Ordinance expand its recycling and other waste diversion programs. Section 716 of the Phoenix Zoning Ordinance establishes standards to encourage the provision of recycling containers for multifamily, commercial and mixed-use developments meeting certain criteria. The applicant indicated in their conceptual site plan that recycling containers will be provided on the site. COMMUNITY INPUT SUMMARY 11. At the time this staff report was written, no correspondence from the public had been received. INTERDEPARTMENTAL COMMENTS 12. Fire Prevention Division, Fire Department Fire Prevention does not anticipate problems with the referenced case. However, the site and or buildings shall comply with the current Phoenix Fire Code (PFC). The water supply (gpm and psi) for the referenced case is unknown and the quantity plus design of fire hydrants shall comply with the PFC. 13. Water Services Department The City of Phoenix Water Services Department has noted the property has existing water and sewer mains that can potentially serve the proposed development. However, there is a potential need to up size existing water and sewer infrastructure mains so that any remodels or new buildings will be able to meet domestic and fire code requirements. Staff Report: Z-23-22-8 June 3, 2022 Page 9 of 12 Findings 1. The proposed development is consistent with the General Plan Land Use Map designation of Residential 15+ dwelling units per acre. 2. The proposal will provide a high quality multifamily residential development which will help alleviate the housing shortage in Phoenix. 3. As stipulated, the proposal is consistent with the character of existing development in the surrounding area. 14. Office of Heat Response and Mitigation The Office of Heat Response and Mitigation has requested that a minimum of 50 percent shade be provided on the public sidewalk and site. Enhanced sidewalk shade standards addressed in Stipulation No. 4. 15. Street Transportation Department The Street Transportation Street Transportation Department has requested that the streets be constructed with all required elements and to ADA requirements. This is addressed in Stipulation No. 6. OTHER 16. This site is located within the noise contour area of Phoenix Sky Harbor International Airport (PHX). As such, staff is requesting that the developer provide notice to prospective purchasers or tenants regarding the existence and operational characteristics of this airport, that an aviation easement be granted and recorded to the City of Phoenix for the site, and that the developer provide a No Hazard Determination from the FAA prior to construction permit approval. These requests are addressed in Stipulation Nos. 7, 8, and 9. 17. The site is located in an area identified as being archaeologically sensitive. If no previous archaeological projects have been conducted within this project area, it is recommended that archaeological Phase I data testing of this area be conducted. Phase II archaeological data recovery excavations may be necessary based upon the results of the testing. A qualified archaeologist must make this determination in consultation with the City of Phoenix Archaeologist. In the event archaeological materials are encountered during construction, all ground disturbing activities must cease within a 33-foot radius of the discovery and the City of Phoenix Archaeology Office must be notified immediately and allowed time to properly assess the materials. This is addressed in Stipulation Nos. 10, 11, and 12. 18. Development and use of the site is subject to all applicable codes and ordinances. Zoning approval does not negate other ordinance requirements. Other formal actions such as, but not limited to, zoning adjustments and abandonments, may be required. Staff Report: Z-23-22-8 June 3, 2022 Page 10 of 12 Stipulations 1. The development shall be in general conformance with the elevations date stamped March 25, 2022, with specific regard to the inclusion of lap siding, metal canopies and CMU veneer, as modified by the following stipulations and approved by the Planning and Development Department. 2. A minimum building setback of 33 feet shall be required along the west property line, as approved by the Planning and Development Department. 3. Minimum 2-inch caliper single-trunk large canopy drought-tolerant shade trees shall be provided along the west property line, planted 20 feet on center or in equivalent groupings, as approved by the Planning and Development Department. 4. The developer shall construct a minimum 5-foot-wide detached sidewalk and minimum 5-foot-wide landscape area located between the back of curb and sidewalk along the west side of 35th Street, as approved by the Planning and Development Department. a. Minimum 2-inch caliper single-trunk large canopy drought-tolerant shade trees shall be provided between the back of curb and sidewalk to provide a minimum 75 percent shade. b. The area between the back of curb and sidewalk shall be planted with drought tolerant shrubs and vegetative groundcovers with a maximum mature height of 24 inches to provide a minimum of 75 percent live coverage at maturity, as approved by the Planning and Development Department. Where utility conflicts exist, the developer shall work with the Planning and Development Department on alternative design solutions consistent with a pedestrian environment. 5. A minimum of six bicycle parking spaces shall be provided through Inverted U and/or artistic racks located near the building entrances or in a secure location inside the building and installed per the requirements of Section 1307.H. of the Phoenix Zoning Ordinance, as approved by the Planning and Development Department. Artistic racks shall adhere to the City of Phoenix Preferred Designs in Appendix K of the Comprehensive Bicycle Master Plan. Staff Report: Z-23-22-8 June 3, 2022 Page 11 of 12 6. The developer shall construct all streets within and adjacent to the development with paving, curb, gutter, sidewalk, curb ramps, streetlights, median islands, landscaping and other incidentals, as per plans approved by the Planning and Development Department. All improvements shall comply with all ADA accessibility standards. 7. The developer shall provide a No Hazard Determination for the proposed development from the FAA pursuant to the FAA’s Form-7460 obstruction analysis review process, prior to construction permit approval, as per plans approved by the Planning and Development Department. 8. The property owner shall record documents that disclose the existence, and operational characteristics of Phoenix Sky Harbor Airport to future owners or tenants of the property. The form and content of such documents shall be according to the templates and instructions provided which have been reviewed and approved by the City Attorney. 9. The developer shall grant and record an avigation easement to the City of Phoenix for the site, per the content and form prescribed by the City Attorney prior to final site plan approval. 10. If determined necessary by the Phoenix Archaeology Office, the applicant shall conduct Phase I data testing and submit an archaeological survey report of the development area for review and approval by the City Archaeologist prior to clearing and grubbing, landscape salvage, and/or grading approval. 11. If Phase I data testing is required, and if, upon review of the results from the Phase I data testing, the City Archaeologist, in consultation with a qualified archaeologist, determines such data recovery excavations are necessary, the applicant shall conduct Phase II archaeological data recovery excavations. 12. In the event archaeological materials are encountered during construction, the developer shall immediately cease all ground-disturbing activities within a 33- foot radius of the discovery, notify the City Archaeologist, and allow time for the Archaeology Office to properly assess the materials. Writer Sarah Stockham June 3, 2022 Team Leader Racelle Escolar Staff Report: Z-23-22-8 June 3, 2022 Page 12 of 12 Exhibits Sketch map Aerial map Site plan date stamped March 25, 2022 (4 pages) Building elevations date stamped March 25, 2022 (2 pages) Z-178-83 * R1-6 R-4A R-4 R-3 R-3 R-3A C-2 R-5 PAD-13 R-4 R1-6 R-3A Z-196-83 WILLETTA ST 36TH ST 35TH ST 34TH ST CULVER ST BELLEVIEW ST 7TH ST 24TH ST 40TH ST 32ND ST 16TH ST BETHANY HOME RD NORTHERN AVE GLENDALE AVE CAMELBACK RD INDIAN SCHOOL RD THOMAS RD MC DOWELL RD VAN BUREN ST WASHINGTON ST 48TH ST 56TH ST 64TH ST SR 51 CAMELBACK EAST VILLAGE CITY COUNCIL DISTRICT: 8 APPLICANT'S NAME: APPLICATION NO. Z-23-22 GROSS AREA INCLUDING 1/2 STREET AND ALLEY DEDICATION IS APPROX. 0.36 Acres MULTIPLES PERMITTED * Maximum Units Allowed with P.R.D. Bonus R1-6 R-4 CONVENTIONAL OPTION 2 10 * UNITS P.R.D. OPTION 2 12 Artin Knadjian DATE: 5/2/2022 REVISION DATES: AERIAL PHOTO & QUARTER SEC. NO. QS 12-35 ZONING MAP G-10 REQUESTED CHANGE: FROM: R1-6 ( 0.36 a.c.) TO: R-4 ( 0.36 a.c.) Document Path: S:\Department Share\Information Systems\PL GIS\IS_Team\Core_Functions\Zoning\sketch_maps\2022\Z-23-22.mxd Z-23-22 0.03 0 0.03 0.015 Miles Z-178-83 * R1-6 R-4A R-4 R-3 R-3 R-3A C-2 R-5 PAD-13 R-4 R1-6 R-3A Z-196-83 WILLETTA ST 36TH ST 35TH ST 34TH ST CULVER ST BELLEVIEW ST 7TH ST 24TH ST 40TH ST 32ND ST 16TH ST BETHANY HOME RD NORTHERN AVE GLENDALE AVE CAMELBACK RD INDIAN SCHOOL RD THOMAS RD MC DOWELL RD VAN BUREN ST WASHINGTON ST 48TH ST 56TH ST 64TH ST SR 51 CAMELBACK EAST VILLAGE CITY COUNCIL DISTRICT: 8 APPLICANT'S NAME: APPLICATION NO. Z-23-22 GROSS AREA INCLUDING 1/2 STREET AND ALLEY DEDICATION IS APPROX. 0.36 Acres MULTIPLES PERMITTED * Maximum Units Allowed with P.R.D. Bonus R1-6 R-4 CONVENTIONAL OPTION 2 10 * UNITS P.R.D. OPTION 2 12 Artin Knadjian DATE: 5/2/2022 REVISION DATES: AERIAL PHOTO & QUARTER SEC. NO. QS 12-35 ZONING MAP G-10 REQUESTED CHANGE: FROM: R1-6 ( 0.36 a.c.) TO: R-4 ( 0.36 a.c.) Document Path: S:\Department Share\Information Systems\PL GIS\IS_Team\Core_Functions\Zoning\sketch_maps\2022\Z-23-22.mxd Z-23-22 0.03 0 0.03 0.015 Miles 38'-0" 2 Y 2 Y UP 8 3 4 5 6 7 2 11 12 13 14 15 10 9 PROPERTY LINE N 35TH STREET ROW = 60 FEET E. CULVER STREET 1 TRASH ENCLOSURE COLLECTION VEHICLE ROUTE IN / BACK UP IN / BACK UP 18'-0" ADA PARKING TYP. PROPERTY LINE 1ST FLOOR PARKING 33'-0" VIEW TRIANGE 33'-0" VIEW TRIANGLE 10'-0" 2 9'-0" PARKING SPACE TYP. 11'-6" ADA PARKING TYP. 4 4 2 120'-0" 85'-0" BSL 15'-0" BSL 20'-0" BSL 10'-0" 76'-0" BSL 10'-0" 96'-0" 11 18'-0" PARKING SPACE TYP. 27'-0 1/8" 6 16 2 2 8 8 5 1 5'-0" 10 5'-0" 9 9 9 9 9 9 14 13 18 17 1 2 3 4 A B C D E 21'-0" 18'-0" 26'-7" 18'-0" 21'-5" 10'-0" 19'-0" 10'-0" 25'-11 3/4" 18'-0" 13'-0 1/4" 14 5'-0" 19 19 5'-0" 2 20 20 20 15 ROW = 50 FEET 7 7 2 21 10'-0" 20'-0" 11. ELEVATOR SHAFT SPACE = 8'-5.0" X 7'- 3.0 SITE PLAN NOTES: 1. DEVELOPMENT AND USE OF THIS SITE WILL CONFORM WITH ALL APPLICABLE CODES AND ORDINANCES 2. THIS PROJECT IS LOCATED IN THE CITY OF PHOENIX WATER SERVICE AREA AND HAS BEEN DESIGNATED AS HAVING AN ASSURED WATER SUPPLY. 3. ALL NEW OR RELOCATED UTILITIES WILL BE PLACED UNDERGROUND. 4. ALL SIGNAGE REQUIRES SEPARATE APPROVALS AND PERMITS 5. ANY LIGHTING WILL BE PLACED SO AS TO DIRECT LIGHT AWAY FROM THE ADJACENT RESIDENTIAL DISTRICTS AND WILL NOT EXCEED ONE FOOT CANDLE AT THE PROPERTY LINE. NO NOISE, ODOR, OR VIBRATION WILL BE EMITTED SO THAT IT EXCEEDS THE GENERAL LEVEL OF NOISE, ODOR OR VIBRATION EMITTED BY USES OUTSIDE OF THE SITE. 6. OWNERS OF PROPERTY ADJACENT TO PUBLIC RIGHT OF WAY WILL HAVE THE RESPONSIBILITY FOR MAINTAINING ALL LANDSCAPING WITHIN THE RIGHTS -OF-WAY IN ACCORDANCE WITH APPROVED PLANS. 7. AFTER FINAL APPROVAL THE PROJECT WILL BE INSPECTED FOR ZONING COMPLIANCE DURING CONSTRUCTION AND PRIOR TO OCCUPANCY. THE APPLICANT IS TO NOTIFY P&D PRIOR TO OCCUPANCY TO ARRANGE FOR INSPECTIONS. CALL 602-262-6981 AND REQUEST A SITE INSPECTION. 8. ALL ROOFTOP EQUIPMENT AND SATELLITE DISHES SHALL BE SCREENED TO THE HEIGHT OF THE TALLEST EQUIPMENT. 9. ALL SERVICE AREAS SHALL BE SCREENED TO CONCEAL TRASH CONTAINERS, LOADING DOCKS, TRANSFORMERS, BACKFLOW PREVENTERS AND OTHER MECHANICAL OR ELECTRICAL EQUIPMENT FROM EYE LEVEL ADJACENT TO ALL PUBLIC STREETS. 10. STRUCTURE AND LANDSCAPING WITHIN A TRIANGLE MEASURED BACK 10' FROM THE PROPERTY LINE AND 20' ALONG THE PROPERTY LINE ON EACH SIDE OF THE DRIVEWAY ENTRANCES WILL BE MAINTAINED AT A MAXIMUM HEIGHT OF 3' 11. STRUCTURE AND LANDSCAPING WITHIN A TRIANGLE MEASURING 33' X 33' ALONG THE PROPERTY LINES WILL BE MAINTAINED AT A MAXIMUM OF 5' 12. FINAL BUILDING PERMIT CANNOT BE OBTAINED UNTIL BONDING OR APPROVED ASSURANCES ARE PROVIDED FOR THE LANDSCAPING WITHIN THE RIGHT - OF - WAY. 13. WALLS ARE NOT APPROVED AS PART OF THE LANDSCAPE PLAN BUT ARE SHOWN FOR REFERENCE ONLY. 14. TREES ADJACENT TO PEDESTRIAN WALKWAYS SHOULD HAVE A MINIMUM CANOPY CLEARANCE OF 6' 8". 15. THE SANITARY SEWER COLLECTION SYSTEM WITHIN THIS PROJECT WILL BE A PRIVATE SYSTEM, OWNED AND MAINTAINED BY THE PROPERTY OWNER(S) OR ASSOCIATION. THE SYSTEM WILL BE RECEIVED AND INSPECTED BY THE BUILDING SAFETY SECTION OF THE PLANNING AND DEVELOPMENT DEPARTMENT. 16. ALL NEW SANITARY SEWER LINES WITHIN THE SITE SHALL BE PRIVATE PLUMBING LINES SUBJECT TO THE PHOENIX PLUMBING CODE OR THE ARIZONA DEPARTMENT OF ENVIRONMENTAL QUALITY (ADEQ) AQUIFER PROTECTION PROGRAM (APP) GENERAL PERMIT 4.01 IN ACCORDANCE WITH ARIZONA ADMINISTRATIVE CODE TITLE 18, CHAPTER 9, SECTION E301 (AAC R18-9-E301) WHICHEVER IS APPLICABLE. 17. ALL ON-SITE WATER LINES, INCLUDING THOSE REQUIRED FOR FIRE PROTECTION SHALL BE PRIVATE PLUMBING LINES SUBJECT TO THE PHOENIX PLUMBING CODE. PROJECT INFORMATION AAK ARCHITECTURE & INTERIORS, INC. 7585 EAST REDFIELD ROAD, SUITE 106 SCOTTSDALE, AZ 85260 CONTACT: ARTIN KNADJIAN TEL: 480.588.5852 EMAIL: ART@AAKAII.COM ARCHITECT: OWNER: FIRST MILL OWNER ADDRESS: 9393 N 90TH ST. UNIT 103-333 SCOTTSDALE, AZ 85258 PROJECT DATA: PARCEL NUMBER: 121-03-020B ADDRESS: 1234 N. 35TH ST., PHOENIX AZ 85008 LOT SIZE: GBA = 14,814 SQ. FT. FAR= 0.8897 MAX HEIGHT ALLOWED: 40'-0" EXISTING ZONING: R1-6 PROPOSED ZONING: R-4 SUBDIVISION: VISTA INCOME ESTATES UNIT 3 PARKING CALCULATIONS: 8 UNITS, ONE AND TWO BEDROOMS x 1.50 SPACES/UNIT = 12 SPACES PLUS 0.5 SPACE/UNIT FOR UNRESERVED SPACES = 0.5 x 8 = 4 SPACES. TOTAL 16 SPACES, 15 SPACES (INCLUDING ONE ACCESSIBLE SPACE ) WITH BONUS OF ( -1.0 SPACE / PROVISION OF TRASH & RECYCLING). PROPOSED LOT COVERAGE: 4,938 SQ. FT. / 11,520 NET SQ. FT. x 100% = 42.86% MAX ALLOWED : 50% PROPOSED 3 STORY BUILDING WITH 8 DWELLING UNITS KEY NOTES VICINITY MAP THIS SITE E. CULVER ST. N. 35TH STREET RED MOUNTAIN FWY (LOOP 202) E MCDOWELL RD N. 40TH ST N. 32ND STREET N.T.S. 0 5 10 20 I CONSENT TO THE REPRODUCTION OF THIS SITE PLAN PROVIDED THAT IF MODIFICATIONS ARE MADE, THE PROFESSIONALS WHO MAKE SUCH CHANGES ASSUME FULL RESPONSIBILITY AND LIABILITY FOR THE MODIFIED PORTIONS OF THE PLAN SIGNATURE OF COPYRIGHT OWNER PRINTED NAME OF COPYRIGHT OWNER DATE THESE PROJECT DOCUMENTS ARE THE PROPERTY OF AAK ARCHITECTURE & INTERIORS, INC. NO PART OF THESE DOCUMENTS SHALL BE REPRODUCED OR USED WITHOUT THE WRITTEN PERMISSION OF THE AUTHORS. COPYRIGHT © 2021 AAK ARCHITECTURE & INTERIORS, INC. PLOT DATETuesday, January 25, 2022 5:13:44 PM 09/09/2021 2125-00 SHEET TITLE JOB NUMBER: DATE: SCALE: REV. CONSTRUCTION PHASE BULLETIN # DATE ISSUED FOR: PRE-CONSTRUCTION PHASE DATE NO. © 2021 7585 e redfield rd #106 scottsdale arizona 85260 480.588.5852 aakaii.com FIRST MILL 1234 N. 35TH ST. PHOENIX, AZ 85005 AS NOTED SITE PLAN scale: 1/8"= 1'-0" 1 A001 SITE PLAN 01-25-2022 SITE PLAN SUBMITTAL 01-25-2022 KIVA #: 22-394 SDEV #: 2200063 PAPP #: 2200664 01-25-202 01-25-202 02 01-25-202 022 Artin Knadjian 03-25-2022 CHANGES ASSUME FULL RESP L RES L RES E LL RES LL E L E L E ONSIBILITY AN MODIFIED PORTION PO PO PO PO PO PO PO PO PO PO P S OF THE OF OF THE H OF THE OF TH OF TH OF OF THE TH OF TH OF TH OF TH OF TH OF TH O H O H OF TH O H O T PLAN SIGNATURE OF COP OF OF OF OF OF OF OF O YRIGHT O HT HT HT HT HT HT HT HT HT HT HT HT HT HT HT HT HT HT WNER 2 Y E. CULVER STREET ROW = 50 FEET UP 2 Y ⅊ ⅊ ⅊ ⅊ UP UP N 35TH STREET ROW = 60 FEET UP MUSEUM PALO VERDE PLANT PALETTE SYMBOL BOTANICAL NAME COMMON NAME SIZE / NOTES TREES MISCELLANEOUS DG TURF (DECOMPOSED GRANITE) NOTE: 2' DEPTH REQUIRED IN ALL PLANTING AREAS SPECIFY AS APPLICABLE CERCIDIUM- PARKINSONIA HYBRID ARIZONA ASH FRAXINUS VELUTINA CHITALPA CHITALPA TASHKENTENSIS AFRICAN SUMAC RHUS IANCEA LIVE OAK QUERCUS VIRGINIANA SHRUBS GREEN HOPSEED DODONAEA VISCOSA PURPE TRAILING VERBENA VERBENA X HYBRIDA SILVER BUSH MORNING GLORY CONVOLVULUS CNEORUM INDIAN LAUREL COLUMNS FICUS NITIDA COLUMNS LANTANA CONFETTI LANTANA CAMARA CONFETTI LANTANA IRENE LANTANA CAMARA IRENE PINK TRAILIG VERBENA VERBENA X HYBRIDA RED TEXAS YUCCA HESPERALOE MATERIAL LEGEND TURF DECOMPOSED GRANITE CONCRETE ASPHALT VICINITY MAP THIS SITE E. CULVER ST. N. 35TH STREET RED MOUNTAIN FWY (LOOP 202) E MCDOWELL RD N. 40TH ST N. 32ND STREET N.T.S. THESE PROJECT DOCUMENTS ARE THE PROPERTY OF AAK ARCHITECTURE & INTERIORS, INC. NO PART OF THESE DOCUMENTS SHALL BE REPRODUCED OR USED WITHOUT THE WRITTEN PERMISSION OF THE AUTHORS. COPYRIGHT © 2021 AAK ARCHITECTURE & INTERIORS, INC. PLOT DATEThursday, March 24, 2022 12:04:42 PM 11/08/2021 2125-00 SHEET TITLE JOB NUMBER: DATE: SCALE: REV. CONSTRUCTION PHASE BULLETIN # DATE ISSUED FOR: PRE-CONSTRUCTION PHASE DATE NO. 01-25-2022 SITE PLAN SUBMITTAL REZONING SUBMITTAL 03-24-2022 © 2021 7585 e redfield rd #106 scottsdale arizona 85260 480.588.5852 aakaii.com FIRST MILL - N 35TH ST 1234 N 35TH ST PHOENIX, AZ 85008 AS NOTED 03-24-2022 KIVA #: 22-394 SDEV #: 2200063 PAPP #: 2200664 A03 CONCEPTUAL LANDSCAPE PLAN CONCEPTUAL LANDSCAPE PLAN scale: 1/8"= 1'-0" 1 BASEMENT PARKING & 03-24-202 03-24-202 03-24 03-24-202 02 24 2 2 2 Y E. CULVER STREET ROW = 50 FEET UP 2 Y ⅊ ⅊ ⅊ ⅊ UP UP N 35TH STREET ROW = 60 FEET UP R.O.W. 30'-0" ROW 15'-0" B.S.L. 10'-0" B.S.L. 20'-0" B.S.L. 10'-0" B.S.L. 15'-0" (15' height bldg.) 34'-6" (TO BLDG) 22'-4" 120'-0" 96'-0" 120'-0" 96'-0" 65'-6" 79'-4" 76'-0" 33'-6" (TO BLDG) 10'-0" 1 1 1 1 1 33'-0" 33'-0" 10'-0" 20'-0" 10'-0" 20'-0" 26'-0" 1 9 7 4 1 9 7 8 7 9 10 10 1 21 5 1 1 1 2 1 1 3 6 10 10 11 12 13 13 14 14 14 15 15 15 15 15 15 20 19 23 24 24 22 22 22 18 26 25 17 16 16 16 7 5'-0" 15'-2" 20'-6" 5'-0" 13'-4" 12'-0" 4'-0" 12'-0" 5'-0" TYP. 5'-0" TYP. 5'-0" TYP. 77'-2" 18'-4" 26'-0" 18'-4" 12'-8" 63'-4" 24 22'-4" R1-6 ADJACENT LOT R-4 ADJACENT LOT 27 28 29 PARKING LEVEL -2'-4" APN: 121-03-020B LOT COVERAGE: MAX ALLOWED : 50% PROPOSED: 43.2% (4,973 / 11,520=0.432) TOTAL DWELLING UNITS / DENSITY: MAX ALLOWED : 29 DU PER ACRE 11 DU FOR THIS SITE (0.382 ACRES GROSS AREA) PROPOSED: 21 DU PER ACRE 8 DU FOR THIS SITE (0.382 ACRES GROSS AREA) HEIGHT / STORIES: MAX ALLOWED : 40 FEET / 3 STORIES NOTE: THERE SHALL BE A 15-FOOT MAXIMUM HEIGHT WITHIN TEN FEET OF A SINGLE-FAMILY ZONED DISTRICT, WHICH HEIGHT MAY BE INCREASED ONE FOOT FOR EACH ADDITIONAL ONE FOOT OF BUILDING SETBACK TO THE MAXIMUM PERMITTED HEIGHT. PROPOSED: 30'-0" FEET / 3 STORIES NOTE: DISTANCE BETWEEN BUILDING AND SINGLE-FAMILY ZONED DISTRICT, (WEST SIDE) IS 33.5 FEET (MINIMUM REQUIRED :30 FEET FOR THIS BUILDING HEIGHT) HEIGHT IS MEASURED FROM GRADE AT STREET LEVEL TO TOP OF ROOF STRUCTURE (PARAPETS NOT INCLUDED) (PARKING LEVEL IS AT 2'-4" BELOW GRADE AT STREET LEVEL) SETBACKS: REQUIRED: FRONT (EAST) : 20 FEET REAR (WEST) : 15 FEET (FOR BLDG HEIGHT 30'-0" MIN. SETBACK: 30'-0") SIDE (NORTH) : 10 FEET SIDE (NORTH) : 10 FEET PROVIDED: FRONT (EAST) : 20 FEET REAR (WEST) : 33.5 FEET SIDE (NORTH) : 10 FEET SIDE (NORTH) : 10 FEET BUILDING AREA & FAR: GROSS FLOOR AREA: 4,973 S.F. GROSS BUILDING AREA (GBA): 14,919 S.F. (4,973 X 3) FLOOR AREA RATIO (FAR): 1.3 (14,919 / 11,520 = 1.295) LOT AREA: NET AREA: 11,520 S.F. (0.264 ACRES) GROSS AREA: 16,650 S.F. (0.382 ACRES) PARKING: REQUIRED: (PER 70.2.C) 1.5 SPACES /PER 1 OR 2 BEDROOM UNIT PLUS 0.5 SPACES /PER 1 OR 2 BEDROOM UNIT PER 702.E.7.b NUMBER OF REQUIRED PARKING MAY BE REDUCED BY 1 SPACE TO INSTALL RECYCLING CONTAINERS ON SITE 8 UNITS x 1.50 SPACES/UNIT = 12 SPACES PLUS 8 UNITS x 0.50 SPACES/UNIT = 4 SPACES SUB TOTAL: 16 SPACES ( -1.0 SPACE / PROVISION OF TRASH & RECYCLING) TOTAL: 15 SPACES PROVIDED: TOTAL: 15 SPACES 14 REGULAR 1 ADA PROJECT DATA: ADDRESS: 1234 N. 35TH ST., PHOENIX AZ 85008 PARCEL NUMBER: 121-03-020B ZONING: EXISTING: R1-6 PROPOSED: R-4 OWNER: FIRST MILL LLC OWNER ADDRESS: 9393 N 90TH ST. UNIT 103-333 SCOTTSDALE, AZ 85258 ARCHITECT: AAK ARCHITECTURE & INTERIORS, INC. 7585 EAST REDFIELD ROAD, SUITE 106 SCOTTSDALE, AZ 85260 CONTACT: ARTIN KNADJIAN TEL: 480.588.5852 EMAIL: ART@AAKAII.COM PROJECT DESCRIPTION /NARRATIVE : THE EXISTING AGED SINGLE FAMILY HOME IS PROPOSED TO BE REPLACED WITH A NEW 8-UNIT MULTI-FAMILY BUILDING . THE FIRST LEVEL OF THE NEW STRUCTURE SHALL BE COVERED PARKING SERVING THE BUILDING, THE SECOND AND THIRD LEVELS WILL BE COMPOSED OF 4 NEW UNITS EACH. OPEN SPACE AREA : MIN. REQUIRED: 833 S.F. (5% OF GROSS AREA - 5% X 16,650) PROVIDED: 915 S.F. VICINITY MAP THIS SITE E. CULVER ST. N. 35TH STREET RED MOUNTAIN FWY (LOOP 202) E MCDOWELL RD N. 40TH ST N. 32ND STREET N.T.S. KEY NOTES I CONSENT TO THE REPRODUCTION OF THIS SITE PLAN PROVIDED THAT IF MODIFICATIONS ARE MADE, THE PROFESSIONALS WHO MAKE SUCH CHANGES ASSUME FULL RESPONSIBILITY AND LIABILITY FOR THE MODIFIED PORTIONS OF THE PLAN SIGNATURE OF COPYRIGHT OWNER PRINTED NAME OF COPYRIGHT OWNER DATE THESE PROJECT DOCUMENTS ARE THE PROPERTY OF AAK ARCHITECTURE & INTERIORS, INC. NO PART OF THESE DOCUMENTS SHALL BE REPRODUCED OR USED WITHOUT THE WRITTEN PERMISSION OF THE AUTHORS. COPYRIGHT © 2021 AAK ARCHITECTURE & INTERIORS, INC. PLOT DATEThursday, March 24, 2022 11:24:33 AM 11/08/2021 2125-00 SHEET TITLE JOB NUMBER: DATE: SCALE: REV. CONSTRUCTION PHASE BULLETIN # DATE ISSUED FOR: PRE-CONSTRUCTION PHASE DATE NO. 01-25-2022 SITE PLAN SUBMITTAL REZONING SUBMITTAL 03-24-2022 © 2021 7585 e redfield rd #106 scottsdale arizona 85260 480.588.5852 aakaii.com FIRST MILL - N 35TH ST 1234 N 35TH ST PHOENIX, AZ 85008 AS NOTED 03-24-2022 KIVA #: 22-394 SDEV #: 2200063 PAPP #: 2200664 A01 SITE PLAN SITE PLAN scale: 1/8"= 1'-0" 1 BASEMENT PARKING & 03-24-202 03-24-202 03-24 03-24-202 02 24 2 2 CHANGES ASSUME FULL RESP L RES ONSIBILITY AND MODIFIED PORTION PO PO PO PO PO PO PO PO PO PO PO PO PO PO PO PO S OF THE F OF TH F OF THE F THE OF THE F THE F E HE F OF THE F TH F OF THE OF THE OF OF THE OF H F H OF H O H PLAN SIGNATURE OF COP F C OF C F C F F OF OF OF YRIGHT O HT HT T O T O HT HT O T HT O T HT T HT HT HT HT HT WNER 03-25-2022 Artin Knadjian ⅊ ⅊ ⅊ ⅊ NEW BUILDING E. CULVER STREET ROW = 50 FEET N 35TH STREET B.S.L. 10'-0" B.S.L. 10'-0" 33'-6" (TO BLDG) B.S.L. 20'-0" B.S.L. 15'-0" CANOPY OVERHANG (30") BALCONY OVERHANG (12") BALCONY OVERHANG (12") BALCONY OVERHANG (12") CANOPY OVERHANG (30") B.S.L. 10'-0" APN: 121-03-020B APN: 121-03-020B VICINITY MAP THIS SITE E. CULVER ST. N. 35TH STREET RED MOUNTAIN FWY (LOOP 202) E MCDOWELL RD N. 40TH ST N. 32ND STREET N.T.S. I CONSENT TO THE REPRODUCTION OF THIS SITE PLAN PROVIDED THAT IF MODIFICATIONS ARE MADE, THE PROFESSIONALS WHO MAKE SUCH CHANGES ASSUME FULL RESPONSIBILITY AND LIABILITY FOR THE MODIFIED PORTIONS OF THE PLAN SIGNATURE OF COPYRIGHT OWNER PRINTED NAME OF COPYRIGHT OWNER DATE THESE PROJECT DOCUMENTS ARE THE PROPERTY OF AAK ARCHITECTURE & INTERIORS, INC. NO PART OF THESE DOCUMENTS SHALL BE REPRODUCED OR USED WITHOUT THE WRITTEN PERMISSION OF THE AUTHORS. COPYRIGHT © 2021 AAK ARCHITECTURE & INTERIORS, INC. PLOT DATEThursday, March 24, 2022 11:24:34 AM 11/08/2021 2125-00 SHEET TITLE JOB NUMBER: DATE: SCALE: REV. CONSTRUCTION PHASE BULLETIN # DATE ISSUED FOR: PRE-CONSTRUCTION PHASE DATE NO. 01-25-2022 SITE PLAN SUBMITTAL REZONING SUBMITTAL 03-24-2022 © 2021 7585 e redfield rd #106 scottsdale arizona 85260 480.588.5852 aakaii.com FIRST MILL - N 35TH ST 1234 N 35TH ST PHOENIX, AZ 85008 AS NOTED 03-24-2022 KIVA #: 22-394 SDEV #: 2200063 PAPP #: 2200664 A02 SITE PLAN SITE PLAN scale: 1/8"= 1'-0" 1 ROOF & NOTE: SEE A01 FOR ADDITIONAL INFORMATION NOT SHOWN ON THIS SHEET 03-24-202 03-24-202 2 03-24-202 02 02 2 2 Artin Knadjian 03-25-2022 HANGES ASSUME F UM UM UM U ULL RESP E ONSIBILI O TY AND LI ODIFIED PORTION PORT RT OR ORT PORT POR ORT RT PORT O PORT RT OR ORT ORT OR OR OR OR POR S OF THE THE TH TH THE THE TH THE THE HE THE THE THE T PLAN PL PL P IGNATURE OF COP CO CO CO CO CO CO CO YRIGHT OWNER W A. STUCCO - BUILDING BODY COLOR: LAZY GRAY, SHERWIN WILLIAMS SW 6254 B. STUCCO - ACCENT / TRIM COLOR: MATCH JAMES HARDIE IRON GRAY C. WALL PANELS - HARDIEPLANK LAP SIDING COLOR: IRON GRAY D. WALL PANELS - HARDIE PANEL VERTICAL SIDING COLOR: IRON GRAY E. TRIM - HARDIE TRIM BOARDS COLOR: SHERWIN WILLIAMS LAZY GRAY SW 6254 F. CMU VENEER COLOR: RED ROCK - TEXTURED MASONRY UNITS BY ECHELON, TRENDRONE G. METAL RAILING : COLOR: MATCH JAMES HARDIE IRON GRAY H. METAL CANOPIES & BALCONY BASE: COLOR: SPICY HUE, SHERWIN WILLIAMS SW6342 WINDOW & DOOR FRAMES COLOR: DARK BRONZE COLORS & MATERIALS: THESE PROJECT DOCUMENTS ARE THE PROPERTY OF AAK ARCHITECTURE & INTERIORS, INC. NO PART OF THESE DOCUMENTS SHALL BE REPRODUCED OR USED WITHOUT THE WRITTEN PERMISSION OF THE AUTHORS. COPYRIGHT © 2021 AAK ARCHITECTURE & INTERIORS, INC. PLOT DATEThursday, March 24, 2022 12:06:14 PM 11/08/2021 2125-00 SHEET TITLE JOB NUMBER: DATE: SCALE: REV. CONSTRUCTION PHASE BULLETIN # DATE ISSUED FOR: PRE-CONSTRUCTION PHASE DATE NO. 01-25-2022 SITE PLAN SUBMITTAL REZONING SUBMITTAL 03-24-2022 © 2021 7585 e redfield rd #106 scottsdale arizona 85260 480.588.5852 aakaii.com FIRST MILL - N 35TH ST 1234 N 35TH ST PHOENIX, AZ 85008 AS NOTED 03-24-2022 KIVA #: 22-394 SDEV #: 2200063 PAPP #: 2200664 SOUTH ELEVATION scale: 1/8"= 1'-0" 1 A05 ELEVATIONS COLORED EAST ELEVATION scale: 1/8"= 1'-0" 2 NORTH ELEVATION scale: 1/8"= 1'-0" 3 WEST ELEVATION scale: 1/8"= 1'-0" 4 03-24-202 3-24-202 03-24-202 02 3-24-20 2 4 2 3-2 2 flats on 35th 1234 EL +0'-0" F.F. STREET LEVEL EL +9'-6" A.F.F. 2ND. FLOOR FINISH FLOOR EL +19'-1" A.F.F EL +34'-0"A.F.F. 3RD. FLOOR FINISH FLOOR TOP OF PARAPET EL +30'-0"A.F.F. TOP OF ROOF MAX. HEIGHT - EL -2'-4" A.F.F. PARKING LEVEL A B C F C C F A 2 6 H H B F G E G 8 EL +0'-0" F.F. STREET LEVEL EL +9'-6" A.F.F. 2ND. FLOOR FINISH FLOOR EL +19'-1" A.F.F EL +34'-0"A.F.F. 3RD. FLOOR FINISH FLOOR TOP OF PARAPET EL +30'-0"A.F.F. TOP OF ROOF MAX. HEIGHT - EL -2'-4" A.F.F. PARKING LEVEL A B A B H A G D 1 H H B F E A B F A B C A EL +0'-0" F.F. STREET LEVEL EL +9'-6" A.F.F. 2ND. FLOOR FINISH FLOOR EL +19'-1" A.F.F EL +34'-0"A.F.F. 3RD. FLOOR FINISH FLOOR TOP OF PARAPET EL +30'-0"A.F.F. TOP OF ROOF MAX. HEIGHT - EL -2'-4" A.F.F. PARKING LEVEL 6 7 3 B F H H G E G EL +0'-0" F.F. STREET LEVEL EL +9'-6" A.F.F. 2ND. FLOOR FINISH FLOOR EL +19'-1" A.F.F EL +34'-0"A.F.F. 3RD. FLOOR FINISH FLOOR TOP OF PARAPET EL +30'-0"A.F.F. TOP OF ROOF MAX. HEIGHT - EL -2'-4" A.F.F. PARKING LEVEL A B A B H A G G D 6 6 7 8 5 9 E H H A B B A. STUCCO - BUILDING BODY COLOR: LAZY GRAY, SHERWIN WILLIAMS SW 6254 B. STUCCO - ACCENT / TRIM COLOR: MATCH JAMES HARDIE IRON GRAY C. WALL PANELS - HARDIEPLANK LAP SIDING COLOR: IRON GRAY D. WALL PANELS - HARDIE PANEL VERTICAL SIDING COLOR: IRON GRAY E. TRIM - HARDIE TRIM BOARDS COLOR: SHERWIN WILLIAMS LAZY GRAY SW 6254 F. CMU VENEER COLOR: RED ROCK - TEXTURED MASONRY UNITS BY ECHELON, TRENDRONE G. METAL RAILING : COLOR: MATCH JAMES HARDIE IRON GRAY H. METAL CANOPIES & BALCONY BASE: COLOR: SPICY HUE, SHERWIN WILLIAMS SW6342 WINDOW & DOOR FRAMES COLOR: DARK BRONZE COLORS & MATERIALS: KEY NOTES: THESE PROJECT DOCUMENTS ARE THE PROPERTY OF AAK ARCHITECTURE & INTERIORS, INC. NO PART OF THESE DOCUMENTS SHALL BE REPRODUCED OR USED WITHOUT THE WRITTEN PERMISSION OF THE AUTHORS. COPYRIGHT © 2021 AAK ARCHITECTURE & INTERIORS, INC. PLOT DATEThursday, March 24, 2022 11:26:09 AM 11/08/2021 2125-00 SHEET TITLE JOB NUMBER: DATE: SCALE: REV. CONSTRUCTION PHASE BULLETIN # DATE ISSUED FOR: PRE-CONSTRUCTION PHASE DATE NO. 01-25-2022 SITE PLAN SUBMITTAL REZONING SUBMITTAL 03-24-2022 © 2021 7585 e redfield rd #106 scottsdale arizona 85260 480.588.5852 aakaii.com FIRST MILL - N 35TH ST 1234 N 35TH ST PHOENIX, AZ 85008 AS NOTED 03-24-2022 KIVA #: 22-394 SDEV #: 2200063 PAPP #: 2200664 SOUTH ELEVATION scale: 1/8"= 1'-0" 1 A04 ELEVATIONS EAST ELEVATION scale: 1/8"= 1'-0" 2 NORTH ELEVATION scale: 1/8"= 1'-0" 3 WEST ELEVATION scale: 1/8"= 1'-0" 4 03-24-202 03-24-202 2 03-24-202 02 02 2 2