05. BA260038 BOA Staff Report

Maricopa County — Board of Adjustment (2026-06-18)

View PDF Item 5 Meeting page

Extracted text (via pymupdf) 26024 characters
Report to the Board of Adjustment 
Prepared by the Maricopa County Planning and Development Department 
Case:   
BA260038 – Remfrey Property Variance 
Hearing Date: 
June 18, 2026 
Supervisor District: 
1 
____________________________________________________________________________________________ 
Applicant:  
Property Owner: 
Request: 
Ted Taber, Taber Custom Homes 
Bradley Remfrey 
Variance to the development standard of the Maricopa County Zoning 
Ordinance to permit: 
1)
Proposed street-side (north) setback of 0’ where 20’ from the street line is
the minimum permitted per MCZO Article 502.
Site Location: 
APN 304-48-023 @ 16915 S 173rd Way – Pecos Rd. and Recker Rd., in the
Gilbert area
Site Size: 
63,305 sq. ft.
Current Use / Zoning: 
Single-family residence / Rural-43
Background: 
1.
1998: The existing home was constructed.
2.
2002: The owner took title to the subject property via Quit Claim Deed MCR20020779345.
3.
April 19, 2025: The applicant applied for permit BLDR2503282 for a detached casita with an
attached garage. Zoning plan review comments noted that the garage was placed too close to the
northern ingress/egress easement.
4.
April 28, 2026: To address the zoning plan review comments, the applicant applied for this
variance to allow a 0’ setback for the casita.
Existing On-Site and Surrounding Zoning/Land Use: 
5.
On-site:
Rural-43 / Single-family residence 
North:
Saragosa St then Rural-43 / Single-family residence 
South:
Rural-43 / Single-family residence 
East:
S Cole Dr then SF-6  / Single-family residence Town of Gilbert 
West:
S 173rd Way then Rural-43 / Vacant 
Variance Request:

Page 2 of 7 
 
6. 
The applicant proposes a 0’ street-side setback from the street line. Without the variance, the 
required street-side setback would be 20’ from the street line, or 32’ from the lot line (12’ 
ingress/egress easement plus the 20’ minimum setback). The applicant indicates they built an 
engineered pad before realizing a variance was required. There does not appear to be a peculiar 
condition or unnecessary hardship preventing development within the principal building envelope. 
 
Excerpt from proposed site plan 
 
 
 
 
Site Analysis: 
 
7. 
The site was developed with the existing residence in the late 1990s and is rectangular in shape. 
There are a few small accessory structures on the eastern side of the parcel. The easement in 
question, E. Saragosa St., extends only about halfway down the northern side of the parcel, 
creating the street-side setback up to the point where the easement ends. With the consent of the 
adjacent property owner, the applicant may choose to abandon this easement, relieving the street-
side setback for both parcels, since both retain access to N 173rd Way. 
 
Aerial photo of subject site 
 
 
 
 
Aerial image & surrounding environs

Page 3 of 7 
 
 
 
Eagle view of subject site looking west into subject parcel (aerial image dated 3/1/25) 
 
 
 
Zoning District map of the Rural-43 zoning district. All other parcels are within the Town of Gilbert.

Page 4 of 7 
 
 
 
 
Zoning District Standards: 
 
8. 
The following table is included to illustrate and contrast the standards for the underlying zoning 
district with those proposed by the owner (Note: changes to proposed standards are indicated in 
bold). 
 
 
 
 
Standard 
 
Rural-43   
Zoning 
District 
Proposed with 
Variance 
Min. Street Side Setback (ADU to north street line)  
20-feet 
0-feet 
 
Note: Standards indicated in bold do not meet base zoning standards 
 
  
 
State Statute / County Zoning Ordinance Tests - ARS § 11-816.B.2 and MCZO Article 303.2.2 states the 
Board of Adjustment may, “Allow a variance from the terms of the ordinance if, owing to peculiar 
conditions, a strict interpretation would work an unnecessary hardship and if in granting the variance the 
general intent and purposes of the zoning ordinance will be preserved.”  
 
9. 
Statutory Test -1 Does the applicant’s property contain any peculiar condition– Discuss and 
explain what is/are the peculiar conditions facing the property and include reference to the 
Maricopa County Zoning Ordinance Regulations or Development Standards to be varied.

Page 5 of 7 
 
 
 
 
10. 
Statutory Test 2 – Does applying the requirements of the Ordinance to the applicant’s property 
create an Unnecessary Hardship – Explain how the peculiar condition identified in #1 causes an  
unnecessary hardship to the property when the requirements of the Maricopa County Zoning 
Ordinance are applied.  Explain how the that the peculiar condition of the property came to be and 
whether the condition was created by the applicant or someone in the property’s line of title. 
Explain the proposed use of the property with the variance request. Identify and explain all 
peculiar conditions on your property in regard to the following areas: slope, narrowness, 
shallowness, irregular shape, location, washes, vegetation, and easements, etc. Explain how 
enforcement of the Zoning Regulations or Development Standards would impose a hardship on 
the property. 
 
 
 
11. 
Statutory Test 3 – General Intent and Purpose of the Zoning Ordinance – Discuss the purpose 
of the zoning requirement from which the variance is being sought. Then, discuss and explain 
how, provided statutory tests #1 and #2 are satisfied, the granting of the requested variance 
would preserve the general intent and purpose of the Zoning Ordinance.

Page 6 of 7 
 
 
 
Findings:  
 
12. 
The applicant has the burden of proving to the Board that, in accordance with the standard set 
forth in ARS §11-816.B.2 and MCZO Article 303.2.2, the property requires a variance. To grant the 
relief, the applicant must prove, and the Board must find and identify, a physical condition of the 
applicant’s property that is peculiar and not common to the area or the universe of the zoning 
district. Also, any such peculiarity must not have been created either by the applicant or anyone 
in the chain of title. If the Board determines that there is no such peculiar physical condition, its 
inquiry stops, and the application must be denied. 
 
If the Board identifies a peculiar physical condition of the applicant’s property which is not self-
imposed, then the applicant must prove, and the Board must find and identify, an unnecessary 
hardship imposed upon the property due to the strict application of the requirements of the zoning 
ordinance which the applicant wishes to have varied such that there is no viable use of the 
property without the variance.  
 
If the Board identifies a peculiar physical condition of the property which is not self-imposed, and 
that in applying the requirements of the zoning ordinance to the property, because of the peculiar 
physical condition, an unnecessary hardship exists, the applicant must prove, and the Board must 
find and identify, how the granting of the variance will preserve the general intent and purpose of 
the zoning ordinance. 
 
In order to approve the variance the Board must make findings and articulate them in motion 
memorializing the above.   
 
13. 
Based upon what the applicant has submitted and the staff analysis in this report, staff offers the 
following positive and/or negative observations the Board may consider in its findings: 
 
• 
There does not appear to be a peculiar condition of this property. It is of a normal size and 
shape. 
• 
The peculiar condition related by the applicant appears to have been self-created rather 
than a topographic or natural feature of the property that warrants a variance for relief. 
• 
The applicant appears to have options available to them such as working with their 
northern neighbor to eliminate the easement. 
• 
It should be noted the northern easement does not run the length of the north lot line. It 
may be possible for the easement to be terminated at a point further to the west. The edge 
of the easement (street line) determines from where the setback is measured. 
 
14. 
And further, if the Board finds the applicant has satisfied the statutory test, and has stated its 
findings on the record, the grant of this variance will memorialize the following:

Page 7 of 7 
a)
Variance approval establishes a 0’ north street-side setback line as measured from the
Presented by: 
Reviewed by: 
Attachments: 
street line for APN 304-48-023.
Joel Landis, Planner 
Darren V. Gérard, AICP, Planning Manager  
Case Map (1 page) 
Supplemental Questionnaire (2 pages) 
Site Plan Drawings (3 pages)

/
Maricopa County Planning & Development - Phoenix, AZ
1
Gross Acres: 2 approx.
Generated May 29, 2026 1:37 PM
BA260038
Application Name:
Legal Description
Meister ADU
Applicant
Case Address
1S-6E-35
Ted  Taber
16915 S 173RD WAY GILBERT, AZ 85295
Applicant Phone/Email
Parcel Primary:304-48-023
(480) 603-5181
GILBERT, AZ 85295
Map scale 1:1,029
Supervisor District No.
Build new 1200 SF ADU adjacent to existing home for aging parents on north boundary within 12' of
property line

LOT 000
1.00 AC.
APN: 304-48-009X
APN: 304-48-009Z
APN: 304-48-021
S 173RD WAY
220'
220'
417.51'
417.51'
172'
172'
APN: 304-48-023
25x25 SVT
25'
25'
3' - 0"
17' - 0"
65' - 0"
23' - 0"
124' - 0"
GATE
6' CNU FENCE 
25'
25'
EGRESS 
12' - 0"
EGRESS 
25' - 0"
GATE
EX-BLDG
544 SF
EX-BLDG
1,386 SF
16' - 0"
34' - 0"
17' - 0"
5' - 0"
42' - 0"
33' - 0"
23' - 0"
90' - 0"
10' - 0"
22' - 0"
6' - 0"
NEW 400A SERVICE
REPLACE 
EX-200AMP SERVICE 
200A SUB PNL.
20'
20'
20'
8'
11'
9'
10'
23'
10'
63'
23'
25'
13'
21'
13'
40'
17'
10'
10' - 0"
ABOVE GROUND
500 LP TANK
10' - 0"
10' - 0"
GARAGE
ENTRY 
28'
PATIO
27'
12'
5'
14'
44'
24'
22'
22'
18'
10'
15' - 0"
EX-LEACH 
WELL
LEACH 
WELL
EX-SEPTIC
TANK
NEW-SEPTIC
TANK
230' - 0"
12' - 0"
30' - 0"
CASITA
5' TALL VINYL FENCE
5' TALL VINAL FENCE
W/M
MAIL BOX
ELECTRICAL
TRANSFMR.
5' TALL VINYL FENCE
5' TALL VINYL FENCE
5' TALL VINYL FENCE
5' TALL VINAL FENCE
357' TO WATER TANK
450' TO WATER TANK
WELL W/ 
10,000G ABOVE
GROUND 
STORAGE TANK
PROJECT SITE 
E PECOS RD
S 172ND WAY
S 173RD WAY
E PECOS RD
NO
DATE
REVISION
This document is for use by RENDERA DESIGN only.
Reproduction of this document, in whole or in part, or the
modification of any detail or design without the expressed written
consent of RENDERA DEISGN is prohibited. All rights reserved.
Copyright 2026.
SHEET TITLE
SHEET NUMBER
PROFESSIONAL SEAL
ISSUE RECORD
DATE  / DESCRIPTION
REVISION RECORD
C O N S T R U C T I O N   D O C U M E N T S
6814 S. BUTTE AVE., TEMPE AZ 85283
PH: (480) 334-5471
RENDERA
D  E  S  I  G  N    L L C
T-1.1
GUEST HOUSE
16915 S 173RD WAY GILBERT, AZ 85295
maricopa county
BRAD REMFREY
SITE PLAN
01.09.2026
NORTH
NORTH
SHEETS INDEX
VICINITY MAP
PROJECT DATA
APN No.:
LOT No. :
LOT SIZE:
ZONING:
SECTION:
STORIES:
ZONING & BUILDING CODE SUMMARY
CODES:
ZONING:
FRONT YARD
-
SIDE YARD
-
REAR YARD
-
BUILDING SETBACKS 
TOTAL UNDER ROOF:
TOWNSHIP:
RANGE:
SUBDIVISION:
CONSTRUCTION YEAR:
TOTAL LAND COVERAGE:
LEGAL DESCRIPTION:
LAT/LOG:
MAX BUILDING HT 
-
16915 S 173RD WAY GILBERT, AZ 85295
maricopa county
16915 S 173RD WAY GILBERT, AZ
85295
maricopa county
1" = 20'-0"
1
ARCHITECTURAL SITE PLAN
2018 1BC
2018 IRC
2018 IMC
2018 IECC
2018 IPC
PLUS  CITY APPLICABLE CODES OR AMENDMENTS
40' FT
2017 NEC
7,821 SF / 63,305 SF = 12.35% < 25% ALLOWED> 
63,305 SF / 1.453 ACRES
304-48-023
-----
-----
RU-43
35
1S
6E
1
0
1998
2,406 SF
20'-30' FT
40' FT
N 172F OF FOL DESC PROP COM AT S4 COR SEC 35 TH N 663.52F TO PT TH E 904.22F TO 
TPOB TH N 327.79F TH E 417.51F TO PT ON ELY LN OF SW4 SE4 TH S 540.90F TO PT TH 
W 417.51F TH N 213.09F TO TPOB
NOTE:
IT IS THE SOLE RESPONSIBILITY OF THE BUILDER TO CONFIRM ALL 
CONDITIONS PRIOR TO LAY-OUT AND ANY DISCREPANCIES REPORTED TO 
THE DESIGNER OR PREPARE OF THE PLANS AND THE ISSUE RESOLVED 
BEFORE PROCEEDING. DURING THE SETTING OF FORMS THE 
DIMENSIONED PLANS SHALL BE USED TO LOCATE ALL CONCRETE 
FOUNDATIONS/SLABS AND FEATURES. IF ANY DISCREPANCIES ARE 
FOUND IT IS THE SOLE RESPONSIBILITY OF THE BUILDER TO CONTACT 
THE DESIGNER OR PREPARE OF THE PLANS AND THE ISSUE BE 
RESOLVED BEFORE PROCEEDING. -ALL SHOWN DIMENSIONS SHALL BE 
CONSIDERED 'CRITICAL' DURING THE FORM SETTING PROCESS ALL 
UNDER-SLAB PLUMBING AND ELEC CONDUITS SHALL BE LOCATED PER 
THE PLANS, IF ANY DISCREPANCIES ARE FOUND IT IS THE SOLE 
RESPONSIBILITY OF THE BUILDER TO CONTACT THE DESIGNER OR PLANS 
PREPARE TO RESOLVE PRIOR TO PROCEEDING. ALL COMMUNICATIONS 
FROM THE BUILDER WHEN CONFIRMING INFORMATION SHALL BE VIA 
EMAIL WITH A WRITTEN NARRATIVE AND INCLUDE A PLAN INDICATING 
THE AREA IN QUESTION. -WORK COMMENCING WITHOUT CONFIRMATION 
OF A RESOLUTION SHALL BE AT-RISK BY THE BUILDER WITH ANY 
DEFECTS/FAILURES/LOSS BECOMING THE FULL LIABILITY OF THE 
BUILDER, IF BUILDER PROCEEDS WITH APPROVAL OF THE OWNER, THE 
OWNER AND BUILDER SHALL BE LIABLE. 
0
40
60
80
20
EX-RESIDENCE
631 SF
EX-GARAGE
400 SF
EX-PATIOS
1,386 SF
EX-MARE MOTEL
544 SF
EX-CHICKEN COOP
TOTAL 5,367 SF
1,232 SF
DETACHED CASITA
CASITA
576 SF
GARAGE
70 SF
FRONT COVERED  PATIO 
576 SF
REAR COVERED  PATIO 
MAIN HOUSE
NO.
SHEETS
SHT ISSUE DATE
REV DELTA <1>
REV ISSUED
REV DATE
T-1.1
SITE PLAN
01.09.2026
No
P-1.0
PLUMBING PLAN LP-GAS PLAN
01.09.2026
No
E-1.0
ELECTRICAL PLAN
01.09.2026
No
30' FT
7,821 SF
TOTAL 2,454 SF

DW
W
D
ELECTRICAL KEY LEDGER:
1.
ALL METAL WATER PIPING WHICH MAY BECOME ENERGIZED
SHALL BE BONDED TOGETHER AND MADE ELECTRICALLY
CONTINUOUS. A BOND OF BARE #4 COPPER WIRE SHALL BE
MADE BETWEEN THE BONDED PIPING SYSTEM AND THE
ELECTRODE CONDUCTOR.
2.
GROUNDING ELECTRODE SYSTEM TO BE PER NEC 250.50 OR IRC
E3508.1 GROUNDING CONDUCTORS INSTALLED IN A POST
TENSION SLAB MUST BE A MIN. OF 12” BELOW GRADE, ENCASED
IN A MIN. 3” CONCRETE.
3.
THE INTERIOR METAL COLD WATER PIPING SYSTEM IS TO BE
BONDED TO THE SERVICE EQUIP. INCLOSURE, THE GROUNDING
CONDUCTOR AT THE SERVICE, THE GROUNDING ELECTRODE, OR
TO ONE OR MORE OF THE GROUNDING ELECTRODES USED.
ELECTRICAL GROUNDING NOTES:
GENERAL ELECTRICAL NOTES:
1.
RECEPTACLES SHALL BE SPACED SO THERE IS NOT A POINT
ALONG THE FLOOR LINE WHICH IS MORE THAN 6’-0" FROM AN
OUTLET PROVIDE (1) ONE OUTLET MIN. FOR EACH COUNTER
WHICH IS 12” OR WIDER, IN KITCHEN AREAS. (MAX. 4’-0” O.C.)
2.
RECEPTACLES IN BATHROOMS, GARAGES, WITHIN 6’-0” OF SINKS
AND ANY EXTERIOR LOCATIONS SHALL BE GROUND FAULT
INTERRUPTION SYSTEM (GFI).
3.
SMOKE DETECTORS SHALL BE PLACED NO MORE THAN 12” FROM
THE CEILING AND 3’-0” FROM DUCT OPENINGS. S.D.’s SHALL BE
PERMANENTLY WIRED AND INTERCONNECTED, AND SHALL
PROTECT ALL SLEEPING AREAS. ALL S.D.'s SHALL HAVE A BATT.
BACK-UP. WHERE THE HIGHEST POINT IN A ROOM THAT OPENS
TO A HALLWAY SERVING THE SLEEPING AREAS EXCEEDS THAT
OF THE OPENING INTO THE HALLWAY BY 24” OR MORE, SMOKE
DETECTORS SHALL BE INSTALLED IN THE HALLWAY AND THE
ADJACENT ROOM. ALL SMOKE DETECTORS SHALL BE INSTALLED
PER THE MFG’S. INSTRUCTIONS.
4.
ALL LIGHTING FIXTURES IN CLOSETS SHALL BE LOC. 24" MIN.
FROM WALLS.
5.
OUTLET BOXES IN WALLS BETWEEN THE DWELLING AND GARAGE
SHALL BE METAL OR U.L. APPROVED PLASTIC.
6.
WN FRONT) ABOVE SINK CABINET DOORS.
7.
PROVIDE (1) ONE, MIN., 20 AMP BRANCH CIRCUIT TO SERVE THE
LAUNDRY ROOM. SUCH CIRCUIT SHALL SHARE NO OTHER
OUTLETS. NEC 210.52(f), IRC E3703.3.
8.
KITCHEN COUNTER TOP RECEPTACLES NEC 210.8(a)(6), IRC
E3703.2, E3901.
9.
MIN. 50 AMP CIRCUIT REQUIRED FOR RANGE AND OR OVEN. FOUR
WIRE RECEPTACLES.
10.
EXTERIOR WATER PROOF G.F.I. OUTLETS TO BE 16” TO CENTER
LINE, PHONE JACKS & T.V. JACKS PER STANDARD APPLICABLE
HEIGHT.
11.
LIGHT FIXTURES LOCATED IN CLOTHES CLOSETS MUST MAINTAIN
12” CLEARANCE PROM SHELVES TO INCANDESCENT  FIXTURES
WITH GLOBE AND 6” CLEARANCE FOR RECESSED AND
FLUORESCENT FIXTURES. INCANDESCENT FIXTURES WITH OPEN
OR PARTIALLY ENCLOSED LAMPS, PENNANT FIXTURES, LAMP
HOLDERS ARE NOT PERMITTED IN CLOSETS.
12.
PROVIDE CONV. WP/OUTLET at EA. AIR HANDLER ON ROOF.
13.
FIXTURES LOCATED IN DAMP OR WET LOCATIONS SHALL BE
LISTED TO BE SUITABLE FOR SUCH LOCATION. NEC 210.8(a)(3),
IRC E4003.9, (SUITABLE FOR WET LOCATIONS or SUITABLE FOR
DAMP LOCATIONS).
14.
WHERE TWO OR MORE 20-AMP PER SMALL APPLIANCE BRANCH
CIRCUITS SHALL HAVE NO OTHER OUTLETS, EXCEPT THE
RECEPTACLE INSTALLED SOLELY FOR ELECTRIC SUPPLY TO AN
ELECTRICAL CLOCK IN THE KITCHEN, DINING, BREAKFAST AREAS
OR RECEPTACLES FOR SUPPLEMENTAL EQUIPMENT AND
LIGHTING FOR GAS-FIRED RANGES, OVENS, OR COUNTER
MOUNTED UNITS NEC 210.5, IRC E3703.2, E3901.
15.
BATHROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED BY AT
LEAST ONE 20-AMP BRANCH CIRCUIT. SUCH CIRCUITS SHALL
HAVE NO OTHER OUTLETS. NEC 210.8, IRC E3703.4.
16.
PROVIDE BONDING TO WATER PIPING. GAS AND METAL BUILDING
SYSTEMS (MINIMUM #4 AWG FOR 200 AMP SERVICE) NEC 250.52,
IRC G2411.1.
17.
ALL RECEPTACLE OUTLETS FOR RANGES AND CLOTHES DRYERS
SHALL BE A 3-POLE WITH GROUND TYPE. FOUR WIRE,
GROUNDING TYPE FLEXIBLE CORDS WILL BE REQUIRED FOR
CONNECTION OF RANGES AND CLOTHES DRYERS. THE BONDING
JUMPER SHALL NOT BE CONNECTED BETWEEN THE NEUTRAL
TERMINAL AND THE FRAME OF THE APPLIANCE. NEC 220.54,
220.55, IRC E3901.
18.
PROVIDE A GROUNDING ELECTRODE OF NOT LESS THAN 20 FEET
OF #4 BARE COPPER (200 AMP SERVICE). NEC 250.52  IRC E3607.4
19.
ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE-PHASE,
15- AND 20-AMP OUTLETS INSTALLED IN DWELLING UNIT
BEDROOMS SHALL BE PROTECTED BY A COMBINATION TYPE
ARC-FAULT CIRCUIT INTERRUPTER(S). NEC 210.12  IRC E3902.
20.
TAMPER RESISTANT RECEPTACLES.
21.
LOCATE KITCHEN DISPOSAL SWITCH IN SINK CABINET (FLIP DOWN
FRONT) ABOVE SINK CABINET DOORS.
GENERAL NOTES:
1.
OUTLET BOX SHALL NOT BE USED AS SOLE SUPPORT FOR
CEILING FANS, EXCEPT BOXES LISTED FOR THE APPLICATION
SHALL BE PERMITTED AS THE SOLE MEANS OF SUPPORT.
2.
INCANDESCENT FIXTURES INSTALLED IN CLOSETS SHALL HAVE
COMPLETELY ENCLOSED LAMPS. SURFACE MOUNTED
INCANDESCENT FIXTURES SHALL BE A MINIMUM OF 12" FROM
THE NEAREST PART OF A STORAGE AREA. SURFACE MOUNTED
FLUORESCENT FIXTURES, RECESSED FLUORESCENT FIXTURES
AND RECESSED INCANDESCENT FIXTURES SHALL BE 6" FROM
THE NEAREST PART OF A STORAGE AREA. NEC 410.120, IRC
E4003.5
3.
INSTALL AN EXHAUST FAN CAPABLE OF 5 AIR CHANGES PER
HOUR, WHICH DISCHARGES OUTSIDE THE BUILDING AT LEAST 3'
FROM ANY OPENING INTO BUILDING  IMC 501.3.
SWITCH PLATES
46" TO TOP
OUTLETS
16" TO TOP
KITCHEN OUTLETS
46" TO TOP
BATHROOM OUTLETS
46" TO TOP
WASHER & DRYERS 
32" TO TOP
LAUNDRY OUTLETS
46" TO TOP
GARAGE OUTLETS
18" TO TOP
GARAGE GOLF CAR OUTLET
60" TO TOP
WATER HEATERS
46" TO  TOP
DOOR BELL BUTTONS
42" TO CL
DOOR BELL CHIME
84" TO TOP
COACH LIGHTS
72" TO CL
WALL LIGHTS 
72" TO CL AFF
VANITY LIGHTS
84" TO CL
GARAGE DOOR PUSHBUTTON
60" TO TOP
GARAGE SWITCHES
46" TO TOP
DEVICE HEIGHTS:
KEYNOTES:
SD/CO
SD
ARC
3
PC
ARC
T
C
EN
M-01
AHU REF. TO MECH.
EQUIPMENT:
E-01
NEW 400 AMP SERVICE PANEL REF. TO SITE
PLAN FOR LOCATION
EQUIPMENT: ELECTRICAL
E-03
ALL EXTERIOR LIGHTING 'DARK SKY
COMPLIANT' REQUIRED REF. TO  ELECTRICAL
E-04
INSTALL AUTOMATIC GARAGE DOOR OPENERS
PER IRC (SEC. R309.4) & UL325 COMPLIANCE.
E-05
LIGHT/ FAN COMBO IN TUB/SHOWERS & DAMP
AREAS SHALL BE  MOISTURE PROOF
E-06
GFI/WP OUTLET 18" MIN. ABOVE FIN. FLOOR.
P-01
LP GAS  WATER HEATER .U.O.N. INSTALL PER
MANUFACTURES SPECIFICATION SHALL
CONFORM TO IRC CH 20, M2005.3, CH 28, 34-43
C-05
CEILING FAN OUTLET BOX SHALL BE RIGIDLY
SECURED IN PLACE. FIELD VERIFY FAN
LOCATION WITH HOME OWNER
DUPLEX RECEPTICAL
ARC FAULT CIRCUIT 
INTERRUPTER PROTECTED RECEPTICAL
WEATHERPROOF GROUND FAULT 
INTERRUPTER RECEPTICAL
GROUND FAULT 
INTERRUPTER RECEPTACL
RECEPTACLE. HALF SWITCHED
220 VOLT OUTLET
SPECIAL PURPOSE OUTLET/JUCTION BOX
WALL SWITCH
THREE-WAY WALL SWITCH
DIMMER SWITCH
CEILING MOUNTED 
HIGH-EFFICACY LIGHT FIXTURE
WALL MOUNTED 
HIGH-EFFICACY LIGHT FIXTURE
CEILING MOUNTED RECESSED 
HIGH-EFFICACY LIGHT FIXTURE
NOTE:
FULLY ENCLOSED IN CLOSET AREAS TYP.
CEILING MOUNTED HIGH-EFFICACY VAPOR PROOF 
LIGHT FIXTURE
CEILING MOUNTED WALL WASHER (LED).
CEILING MOUNTED PULL CHAIN. (LED).
CEILING MOUNTED PENDANT. (LED).
EXUAST FAN (VENT THROUGH ROOF)
EXHAUST FAN W/ VAPOR PROOF LIGHT 
(VENT THROUGH ROOF)
TELEPHONE (RECEPTICAL)
EITHER NET (RECEPTICAL)
CABLE / TV (RECEPTICAL)
12" X 48" SINGLE LED LIGHT FIXTURE 
220V DISCONNECT AC UNIT
CEILING FAN W/ LIGHT OUTLET BOX 
SHALL BE RIGIDLY SECURED IN PLACE
FIELD VERIFY FAN LOCATION 
WITH HOMEOWNER
20W DUAL-HEAD DUSK LED OUTDOOR SECURITY 
LIGHT MOUNTED ON EXTERIOR WALL @ + 96" UNLESS 
NOTED OTHERWISE.
SMOKE DETECTOR INTERCONNECTED SHALL BE 
PERMANENTLY WIRED W/ BATTERY BACKUP. 
COMBO SMOKE DETECTOR / CARBON MONOXIDE 
DETECTORS.
LOW VOLTAGE SWITCH FOR GARAGE DOOR CEILING.
VP
E
E
D
E-02
200A SUB PANEL @ CASITA
C-03
22x30 ATTIC ACCESS W/ LIGHT SWITCH AT
SCUTTLE.
E-07
SMOKE & CARBON MONOXIDE ALARMS SHALL
BE PERMANENTLY WIRED W/ BATTERY BACKUP
SEE ELECTRICAL
240V
WP/GFI
AFIC/GFCI
ARC
KITCHEN
BATH
WALK IN CLO.
CLO.
MASTER BEDROOM
LIVING ROOM
GUEST / FLEX SPACE
PANTRY
CLO
PANTRY
MUD ROOM
BATH
DOUBLE GARAGE
W/H
C-03
C-05
AFIC/GFCI
AFIC/GFCI
AFIC/GFCI
240V
42"
42"
WP/GFI
C-05
C-05
ARC
ARC
ARC
ARC
ARC
ARC
AFIC/GFCI
E
E
VP
VP
E
VP
E
ARC
ARC
ARC
ARC
AFIC/GFCI
SHOWER
ARC
ARC
ARC
ARC
ARC
ARC
ARC
ARC
ARC
ARC
ARC
ARC
AFIC/GFCI
AFIC/GFCI
ARC
AFIC/GFCI
AFIC/GFCI
AFIC/GFCI
AFIC/GFCI
AFIC/GFCI
AFIC/GFCI
WP/GFI
ARC
18"
ARC
ARC
ARC
ARC
AFIC/GFCI
WP/GFI
ATTIC 
LIGHT
ATTIC 
LIGHT
AH-1 IN 
ATTIC
WP/GFI
E-02
E-04
E-03
E-03
E-03
E-03
E-06
M-01
HP-1
SD
SD
SD/CO
EN
EN
EN
EN
P-01
LP-GAS 
RANGE
LP-GAS 
DRYER
LP-GAS 
WATER
HEATER
E-07
E-07
E-07
NEW 400A, 120/240V, I-PHASE, 3W, NEMA 3R
U.L. AND POWER CO. APPROVALS REQUIRED
BRACE FOR MAX. AVAILABLE CURRENT
200/2 MCB
#2/0 CU. BONDING
JUMPER PER IRC E3508.
NEW
PANEL 'A'
#I/0 CU. BOND TO METALIC
GAS MAIN PER IRC E3508
#I/0 CU. BOND TO METALIC
WATER MAIN PER IRC E3508
MIN.
6'.
MOUNT TO THE SIDE OF 
METER PANEL CENTER
3/4" DIA X 10' LONG COPPER
GROUND RODS INSTALLATION
PER IRC E3508
EXIST. CONDUIT FOR 
SECONDARY'S PER POWER CO. 
REQUIREMENTS
NOTE: 1.  ALL CONDUCTORS SIZED BASED ON TYPE 'XHHW' & 'THHN/THWN' COPPER.
MAX. AVAILABLE FAULT CURRENT (A.F.C.)
=28,539 SYMM. AMPS. ELEC. CONTRACTOR
SHALL VERIFY WITH POWER CO. BEFORE 
ORDERING METER/PANEL CENTER.
M
# I/0 CU. BOND TO METALIC
GAS MAIN PER IRC E3508
# I/0 CU. BOND TO METALIC
WATER MAIN PER IRC E3508
# 4 CU. UFER
NEW
PANEL 'G'
SERVICE 
EQUIPMENT 
RATED
3 #3/0 CU.
#8 CU INSULATED
BOND 1 1/2" C.
NEW #2/0 CU
CASITA PANEL 'B' 
LOAD CALC.
1,232 SF
GENERAL LIGHTING / RECEPTACLES @  3.0VA PER SF 
=
 3,696 VA
SMALL APPLIANCES - 2 CIRCUITS
1,500VA  EA. 
=
 3,000 VA
LIVING ROOM
1,500VA  EA.
=
 1,500 VA
WASHER
=
 1,500 VA
DRYER
=
 1,500 VA
DISPOSER
=
 600 VA
REFRIGERATOR/FREEZE
=
 1,500 VA
MICROWAVE
=
 1,500 VA
HOOD
=
 500 VA
RANGE/OVER
=
 1,500 VA
WATER HEATER 
=
 1,500 VA
GARAGE DOOR OPENER (1)
1,500VA EA.
=
 1,500 VA
GFCI CIRCUITS (6)
 6= 1,500VA EA.
=
 9,000 VA
TOTALS OTHER LOADS
=
28,796 VA
FIRST 10KVA @ 100%
=
10,000 VA
REMAINER @ 40% 
=
 7,518 VA
TOTAL OTHER LOADS
=
17,518 VA
HP-1  (32.0 MCA)
=
 6,400 VA
TOTAL VA
=
23,918 VA
+
240 VOLTS
 99.66 AMPS
PANLE IS PART OF THE ALL-IN ONE SERVICE ENTRANCE SECTION
WIRE
SIZE
CU.
PANEL B
WIRE
SIZE
CU.
200 AMP
120/240V., 1PH, 3W
LOCATION    SERVICE
TYPE PLUG-ON
BREAKER RATING 10,000 A/C
USE/AREA SERVICE
CB
No
No
USE/AREA SERVICE
MAIN 200A MCB
NEMA 3R SURF MTG
TOTAL (CONNECTED)
25% CONTINUOUS
TOTAL (CODE)
AFCI CIRCUIT BREAKER.
#12'S
15
I
I
I
I
I
I
I
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
CB
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
LGT - KITCHEN/LIVING ROOM
#14'S
#14'S
PWR / LTG-LIVING ROOM
#14'S
PWR / LTG-LIVING ROOM
#14'S
PWR / LTG-GEST/FLEX SPACE
#14'S
#14'S
15
15
15
15
15
15
15
15
#14'S
PWR / LTG-MASTER BEDROOM
#14'S
PWR / LTG-ENTRY
#12'S
GARAGE DOOR OPENER (GFCI)
#12'S
GARAGE DOOR OPENER (GFCI)
#12'S
(GFCI) RECEPTS - GARAGE
SMOKE DETECTOR
I
I
I
I
I
I
I
I
I
I
20
20
20
20
20
20
20
20
LOAD
L1
L2
#12'S
SMALL APPLIANCE CIRCUIT
#12'S
SMALL APPLIANCE CIRCUIT
#12'S
DISHWASHER (GFCI)
#12'S
DISPOSER (GFCI)
#12'S
#12'S
REFRIGERATOR / FREEZER 
#12'S
RANGE/OVEN
20
I
20
I
20
I
20
I
20
I
20
I
#12'S
DRYER
20
I
#12'S
LAUNDRY (GFCI)
#6'S
50
2
HP1 A/C UNIT 
SPACE FOR SOLAR 
ELEC. EQPT.
VENT HOOD 
(GFCI) RECEPTS - BATH 
(GFCI) RECEPTS - MASTR BATH
#12'S
#12'S
#12'S
#12'S
#12'S
#12'S
#12'S
(GFCI) RECEPTS - EXTERIOR
20
I
WATER HEATER
MICROWAVE
VA / 120V. = 99.66A
LGT - KITCHEN/LIVING ROOM
I
20
20
I
#12'S
I
20
#12'S
AH-1 (ATTIC UNIT)
1/4" = 1'-0"
2
ELECTRICAL PLAN
NO
DATE
REVISION
This document is for use by RENDERA DESIGN only.
Reproduction of this document, in whole or in part, or the
modification of any detail or design without the expressed written
consent of RENDERA DEISGN is prohibited. All rights reserved.
Copyright 2026.
SHEET TITLE
SHEET NUMBER
PROFESSIONAL SEAL
ISSUE RECORD
DATE  / DESCRIPTION
REVISION RECORD
C O N S T R U C T I O N   D O C U M E N T S
6814 S. BUTTE AVE., TEMPE AZ 85283
PH: (480) 334-5471
RENDERA
D  E  S  I  G  N    L L C
E-1.0
GUEST HOUSE
16915 S 173RD WAY GILBERT, AZ 85295
maricopa county
BRAD REMFREY
ELECTRICAL PLAN
01.09.2026
N.T.S
ONE- LINE DIAGRAM
N.T.S
CASITA PANEL LOAD CALCULATION
N.T.S
CASITA PANLE SCH.
NORTH

DW
W
D
ABOVE GROUND 
500G LP-GAS 
10' - 0"
KITCHEN
SHOWER
BATH
WALK IN CLO.
CLO.
MASTER BEDROOM
LIVING ROOM
GUEST / FLEX SPACE
PANTRY
CLO
PANTRY
MUD ROOM
BATH
DOUBLE GARAGE
2"
(SCH. 40)
2"
(SCH. 40)
2"
(SCH. 40)
3/4"
(SCH. 40)
26'-8"
4'-4"
10'-8"
11'-8"
10'-0"
4'-8"
4'-0"
RANGE FREE 
STANDING
60,000 b.t.u.
WATER HEATER
30,000 b.t.u.
3/4" 
(SCH. 40)
1/2" 
(SCH. 40)
CLOTHES DRY
22,000 b.t.u.
NOTE:
LENGTH OF PIPE NOTATIONS ARE 
(APPROXIMATE MEASUREMENT)
1 1/2"
(SCH. 40)
NO
DATE
REVISION
This document is for use by RENDERA DESIGN only.
Reproduction of this document, in whole or in part, or the
modification of any detail or design without the expressed written
consent of RENDERA DEISGN is prohibited. All rights reserved.
Copyright 2026.
SHEET TITLE
SHEET NUMBER
PROFESSIONAL SEAL
ISSUE RECORD
DATE  / DESCRIPTION
REVISION RECORD
C O N S T R U C T I O N   D O C U M E N T S
6814 S. BUTTE AVE., TEMPE AZ 85283
PH: (480) 334-5471
RENDERA
D  E  S  I  G  N    L L C
P-1.0
GUEST HOUSE
16915 S 173RD WAY GILBERT, AZ 85295
maricopa county
BRAD REMFREY
PLUMBING PLAN
LP-GAS PLAN
01.09.2026
1/4" = 1'-0"
1
LP-GAS PLAN
NORTH