Extracted text (via pymupdf_layout)
32095 characters
CONSULTANT TEAM APPROVALS AT&T CLIENT REPRESENTATIVE AT&T (RF): DATE: PUBLIC SAFETY TOWERS COMPANY 701 PALOMAR AIRPORT RD #160 AT&T (CONST.): DATE: CARLSBAD, CA 92011 CONTACT: SAM GUDINO EMAIL: S.GUDINO@PSTCTOWERS.COM AT&T (S.A.): DATE: 1355 W. UNIVERSITY DRIVE PHONE: (760) 612-9949 MESA, AZ 85201 LANDLORD: DATE: PROJECT OWNER AT&T MOBILITY 1355 W. UNIVERSITY DRIVE MESA, AZ 85201 PROJECT DESCRIPTION CONTACT: DR. ANIL CHERUVU PHONE: (602) 625-3973 EMAIL: ac7856@ATT.COM GROUND SCOPE PROPERTY OWNER INSTALL A NEW UL LISTED WALK-UP CABINET (W.U.C.) & BATTERY CABINET SUPPORTED BY CONCRETE SLABS COMMERCIAL RESOURCE INVESTORS III, LLC WITHIN A NEW CMU WALLED COMPOUND TO INCLUDE THE FOLLOWING: 3855 W. RAY ROAD, #3 • (1) NEW [CEQ.54298] VERTIV, F2020030,,,, UL LISTED VERTIV WUC 3-BAY WALK-UP CABINET (W.U.C.) - ON CHANDLER, AZ 85226 CONCRETE SLAB • (1) NEW [NEQ.15918] VERTIV, F2012495 -48 VDC XTE 601B BATTERY ENCLOSURE W/ (5) BATTERY SHELVES W/ A&E CONSULTANT TEAM MAX CAPACITY OF (6) -48V BATTERY STRINGS (FULLY LOADED) 701 PALOMAR AIRPORT RD #160 YOUNG DESIGN CORP, LLC. • (1) NEW GPS ANTENNA MOUNTED TO WUC PIPE CARLSBAD, CA 92011 10245 E. VIA LINDA • (6) NEW U.G. 4" PVC CONDUIT RUNS FROM WUC SPD BOX TO TOWER SCOTTSDALE, AZ 85258 PROJECT: NEW BUILD IWM JOB #1: WSANM0039718 (PARENT) • (2) NEW SCHD 40 PVC 2" Ø U.G. CONDUIT W/ (3) 1.25 Ø INNERDUCTS FROM CARRIER FIBER VAULT TO WUC CONTACT: MATT YOUNG • (2) 2" CONDUITS W/ (2) 4/0s PER CONDUIT FOR WIRING PHONE: (480) 451-9608 EMAIL: MATT.YOUNG@YDCOFFICE.COM PTSC SITE NO.: GOODAZ-0284 IWM JOB #2: WSANM0039653 • NEW VERTIV DC50 SPD MOUNTED TO WUC • NEW 600AMP METER SERVICE W/ 200AMP METER SOCKET FOR AT&T CONTACT: CHRISTIAN JESPERSON SITE NAME: MCCLINTOCK IWM JOB #3: WSANM0039803 • NEW U.G. CONDUITS FOR ELECTRICAL SERVICE PHONE: (480) 235-2729 EMAIL: CHRISTIAN.JESPERSON@YDCOFFICE.COM • NEW FIBER SITE VAULT AT&T SITE ID / FA: AZL01562 / 15458390 IWM JOB #4: WSANM0039781 • NEW GROUND RING TOWER OWNER PUBLIC SAFETY TOWERS COMPANY USID: 503892 IWM JOB #5: WSANM0039740 TOWER SCOPE 701 PALOMAR AIRPORT RD #160 BY AT&T: CARLSBAD, CA 92011 ADDRESS: 3875 W. RAY ROAD IWM JOB #6: WSANM0039700 • NEW 65'-0" AT&T MONOBROADLEAF TOWER (70' OVERALL HEIGHT) CONTACT: SAM GUDINO • (1) NEW AT&T APPROVED ANTENNA MOUNTS PHONE: (760) 612-9949 EMAIL: S.GUDINO@PSTCTOWERS.COM CHANDLER, AZ 85226 IWM JOB #7: WSANM0039654 • (3) NEW COMMSCOPE NNHH-65C-R4 ANTENNAS, (1) PER SECTOR • (3) NEW ERICSSON AIR 6472 B77G / B77M ANTENNAS, (1) PER SECTOR IWM JOB #8: WSANM0039628 • (3) NEW COMMSCOPE NNH4-65C-R6-V4 ANTENNAS, (1) PER SECTOR • (3) NEW ERICSSON 4478 B12A, (1) PER SECTOR IWM JOB #9: WSANM0039627 • (3) NEW ERICSSON 4890 B25/B66, (1) PER SECTOR • (3) NEW ERICSSON 4494 B14/B29, (1) PER SECTOR • (2) 24-PAIR FIBER 36SM TRUNK CABLES, (1) PER SQUID GENERAL NOTES DRIVING DIRECTIONS JURISDICTIONAL APPROVAL • (4) #6 AWG DC PWRT-606-S POWER TRUNK CABLES, (2) PER SQUID • (2) NEW RAYCAP DC9-48-60-24-8C-EV DC SQUIDS PROJECT: NEW BUILD CONTRACTOR & CREWS SHALL ABIDE BY AT&T CONSTRUCTION STANDARDS/REQUIREMENTS AS DESCRIBED IN DIRECTIONS: ELECTRICAL SCOPE PTSC SITE NO.: GOODAZ-0284 THE AT&T SAFETY HANDBOOK. • (1) 15A BREAKERS FOR SIAD DEPARTING FROM AT&T OFFICE: 1355 WEST UNIVERSITY DRIVE, MESA, AZ • (2) 20A BREAKER FOR GEN 3 / GEN 4 BBU SITE NAME: MCCLINTOCK OSHA REGULATIONS/STANDARDS SHALL BE REVIEWED & FOLLOWED BY ALL EQUIPMENT INSTALLERS AND 85201-5419: GET ON AZ-101 LOOP S IN TEMPE FROM W. UNIVERSITY DR. • (3) 25A BREAKERS FOR B12A RRHS AT&T SITE ID / FA: AZL01562 / 15458390 TOWER/ROOF TOP CONTRACTORS/SUBCONTRACTORS DURING CONSTRUCTION. FOLLOW AZ-101 LOOP S TO N. PRICE RD IN CHANDLER. TAKE EXIT 59 FROM • (3) 40A BREAKERS FOR INTEGRATED RADIOS USID: 503892 AZ-101 LOOP S. TAKE W. RAY RD TO YOUR DESTINATION. • (3) 50A BREAKERS FOR B14/B29 RRHS THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL FAULTY, INFERIOR AND/OR • (3) 50A BREAKERS FOR B25/B66 RRHS ADDRESS: 3875 W. RAY ROAD IMPROPER MATERIALS, DAMAGED GOODS, AND/OR FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE • (2) 60A BREAKERS FOR FUSE PANEL CHANDLER, AZ 85226 PROJECT IS COMPLETE AND ACCEPTED UNDER THIS CONTRACT: UNLESS NOTED OTHERWISE IN THE • INSTALL (8) NEW MARATHON M12V180FTX BATTERIES COUNTY: MARICOPA COUNTY CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. (EXCEPTION) THE ROOFING SUBCONTRACTOR • WUC CABINET HAS NO HVAC. 6KW 512 DC PLANT W/ DC-POWERED HEAT EXCHANGERS ARE INSTALLED IN SHALL FURNISH A MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE GENERAL EACH BAY CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A PERIOD OF TWO (2) YEARS • EMERSON 7100 -48VDC POWER PLANT OUTFITTED WITH (10) HE 2kW -48VDC RECTIFIERS, 58VDC STARTING AFTER THE DATE OF SUBSTANTIAL COMPLETION OF THE PROJECT, UNLESS OTHERWISE WRITTEN IN CONVERTERS THE CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. THESE PLANS HAVE BEEN DEVELOPED FOR A NEW TELECOMMUNICATIONS FACILITY OWNED OR LEASED BY AT&T IN ACCORDANCE WITH THE SCOPE OF WORK PROVIDED BY AT&T. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY OF THE OWNER'S EMPLOYEES, WORKMEN, AND ALL TIMES DURING THE CONSTRUCTION OF THE PROJECT. VICINITY MAP THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS AND/OR FEES WITH RESPECT SHEET INDEX TO THE WORK TO COMPLETE THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BE THE OWNER OR HIS REPRESENTATIVE. CONTRACTOR SHALL OBTAIN PERMIT AND MAKE FINAL PAYMENT FOR SAID DOCUMENT. SHEET # DESCRIPTION AT&T GC TO VERIFY ALL MEASUREMENTS OF EXISTING CONDUITS FOR FIBER RUN AND ANY POWER RUNS. T-1 TITLE SHEET FINAL CMJ MAY D 5/1/2026 ZONING DRAWINGS DO NOT SCALE DRAWINGS LS-1 SURVEY BOUNDARY 90% REVISED LS-2 SURVEY DETAIL C 8/21/2025 CMJ MAY PRELIMINARY ZD'S 90% PRELIMINARY B 7/23/2025 CMJ MAY SITE INFORMATION ZD'S A-1.0 UTILITY SITE PLAN DRIVE LEASE PROPERTY OWNER: COMMERCIAL RESOURCE A-2 NEW ENLARGED COMPOUND PLAN A 6/9/2025 CMJ MAY EXHIBIT INVESTORS III, LLC A-3 ANTENNA LAYOUT & DETAILS 3855 W. RAY RD, #3 PROFESSIONAL SEAL MCCLINTOCK CHANDLER, AZ 85226 A-3.1 EXISTING ELEVATIONS A-4 NEW ELEVATIONS N. APPLICANT: PUBLIC SAFETY TOWERS COMPANY 701 PALOMAR AIRPORT RD #160 N CARLSBAD, CA 92011 W. RAY ROAD ONLY CONTACT: SAM GUDINO PHONE: (760) 612-9949 WINDMILLS PRELIMINARY BOULEVARD EMAIL: S.GUDINO@PSTCTOWERS.COM DRAWINGS TOWER TYPE: MONOBROADLEAF SITE N. CALL 811 or (800) 782-5348 ZONING SITE TYPE: WIRELESS COMMUNICATIONS FACILITY WWW.ARIZONA811.COM CONTRACTOR TO CALL TO VERIFY APN: 301-64-876 R UTILITIES AT LEAST TWO WORKING DAYS PRIOR TO DIGGING FOR LATITUDE 33° 19' 09.396" N 33.319277° LONGITUDE 111° 54' 34.393" W APPLICABLE CODES RFDS DATA SUMMARY YDC PROJECT NUMBER -111.909554° DESIGN PACKAGE BASED ON RF DATA SHEET YDC-11352 EXISTING ELEVATION: ±1179.5' SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, RFDS NAME: GOODAZ-0284_RFDS_Prelim_2026-04-24.pdf STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING RFDS ID: RFDS-24510 EXISTING ZONING: PAD JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED VERSION: 1.0 CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL RFDS DATE: 14/03/2024UPDATED BY ac7856 ON 24/04/2026 SHEET TITLE CONSTRUCTION TYPE: V-B GOVERN THE DESIGN. SUMMARY OF EQUIPMENT: PROPOSED LEASE AREA: 756.42 SQ FT. (PSTC LEASE AREA) 1. BUILDING CODE: INTERNATIONAL BUILDING CODE 2024 NUMBER OF SECTORS: . . . . . . . . . . . . . . 3 2. ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2023 NUMBER OF ANTENNAS: . . . . . . . . . . . . . 9 3. LIGHTNING PROTECTION CODE: NFPA 780-2017, LIGHTNING PROTECTION NUMBER OF RRH'S: . . . . . . . . . . . . . . . 9 TITLE SHEET PROPOSED OCCUPANCY: UNMANNED TELECOMMUNICATIONS FACILITY NUMBER OF FIBER OPTIC CABLES (JUMPERS) . . 1 CODE NUMBER OF FIBER/DC SQUIDS: . . . . . . . . . 2 4. EIA/TIA 222G EXISTING OCCUPANCY: UNMANNED TELECOMMUNICATIONS FACILITY NUMBER OF FIBER TRUNK CABLES . . . . . . . 2 NUMBER OF DC TRUNK CABLES . . . . . . . . . 4 FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS JURISDICTION: CITY OF CHANDLER REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER SHEET NUMBER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. ELECTRICAL PROVIDER: SRP WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. FIBER PROVIDER: COX T-1 THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. E. WARNER RD. FLOOD ZONE DESIGNATION SURVEYOR NOTES SCHEDULE B EXCEPTIONS THE PROPOSED LEASE PREMISES SHOWN HEREON APPEAR TO BE WITHIN FLOOD 1. ALL TITLE INFORMATION IS BASED UPON A COMMITMENT FOR TITLE 4.1 EASEMENT BY COMMERCIAL RESOURCE INVESTORS III, L.L.C., AN RD ZONE "X" AS DELINEATED ON THE FEDERAL EMERGENCY MANAGEMENT AGENCY INSURANCE PREPARED U.S. TITLE SOLUTIONS, ORDER NO.: UST81269 ARIZONA LIMITED LIABILITY COMPANY TO TUTOR SOUTH TEMPE GROUP, RD. FIRM MAP NO. 04013C2710L DATED 10/16/2013. EFFECTIVE DATE: 09/23/2025. LLC, AN ARIZONA LIMITED LIABILITY COMPANY, DATED APRIL 23, 2007, RURAL RECORDED APRIL 24, 2007, IN INSTRUMENT NO: 2007-0475189. FLOOD ZONE "X" IS DEFINED AS: AREAS DETERMINED TO BE OUTSIDE 500-YEAR 2. SURVEYOR HAS NOT PERFORMED A SEARCH OF PUBLIC RECORDS TO NOTES: SEWER S. E. RAY RD FLOODPLAIN; DETERMINED TO BE OUTSIDE THE 1% AND 0.2% ANNUAL CHANCE DETERMINE ANY DEFECT IN TITLE. MCCLINTOCK FLOODPLAINS. 4.2 EASEMENT BY RAY & MCCLINTOCK ASSOCIATES LIMITED PARTNERSHIP, 3. THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD AN ARIZONA LIMITED PARTNERSHIP TO SALT RIVER PROJECT INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF E. AGRICULTURAL IMPROVEMENT AND POWER DISTRICT, A THE PROPERTY. POLITICAL SUBDIVISION OF THE STATE OF ARIZONA, DATED FEBRUARY PROJECT META DATA 14, 1994, RECORDED MARCH 01, 1994, IN INSTRUMENT NO: 94-0170395. 4. SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR E. CHANDLER BLVD. NOTES: UNDERGROUND ELECTRICAL 1. ELEVATIONS SHOWN HEREON ARE REPRESENTED IN NORTH THEIR LOCATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND AMERICAN VERTICAL DATUM OF 1988 (NAVD88) ESTABLISHED FROM DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED GPS DERIVED ELLIPSOID HEIGHTS, APPLYING GEOID 18B SEPARATIONS AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. 4.3 EASEMENT BY RAY & MCCLINTOCK ASSOCIATES LIMITED PARTNERSHIP, CONSTRAINING TO NGS CORS STATIONS PROVIDED IN THE "ONLINE REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY AN ARIZONA LIMITED PARTNERSHIP TO SALT RIVER PROJECT POSITIONING USER SERVICE" (OPUS) SOLUTION FOR THIS SPECIFIC OF THE CONTRACTOR. AGRICULTURAL IMPROVEMENT AND POWER DISTRICT, A SITE. POLITICAL SUBDIVISION OF THE STATE OF ARIZONA, ITS SUCCESSORS AND ASSIGNS, DATED JUNE 13, 1991, RECORDED JUNE 21, 1991, IN 2. BEARINGS SHOWED HEREON ARE BASED UPON U.S. STATE PLANE INSTRUMENT NO: 91-286026. NAD83 COORDINATE SYSTEM ARIZONA STATE PLANE COORDINATE NOTES: UNDERGROUND ELECTRICAL CONDUIT ZONE CENTRAL, DETERMINED BY GPS OBSERVATIONS. LESSOR'S LEGAL DESCRIPTION ITEMS 1 THRU 3, 4.4 - 4.10, 5.1 - 6.2 OF THE CLIENT PROVIDED TITLE 3. FIELD WORK FOR THIS PROJECT WAS PERFORMED ON 07/02/25. LOT 4, RAY & MCCLINTOCK PLAZA, ACCORDING TO BOOK 327 OF MAPS, PAGE 42, REPORT DO NOT CONTAIN GRAPHICALLY PLOTTABLE EASEMENTS, RECORDS OF MARICOPA COUNTY, ARIZONA. SETBACKS, RESTRICTIONS OR OTHER ENCUMBRANCES. THE SURVEYOR CANNOT GUARANTEE THAT NON-PLOTTABLE ENCUMBRANCES DO NOT EXIST THAT MAY AFFECT THE SUBJECT LEASED PREMISES. architecture / project management 10245 E. Via Linda, Scottsdale, AZ 85258 ph: 480 451 9609 fax: 480 451 9608 e mail: corp@ydcoffice.com W W W W W W G W W W W SS SS SS SS SS SS SS SS SS FND SS SS SS SS SS SS S SS SS SS SS SS S SS W BCFL G FIELD BY: TG SS W DRAWN BY: JMM FO FO FO FO FO FO FO FO FO G T SS T H Y D E UGE UGE ET UGE UGE UGE UGE PARCEL CHECKED BY: RLF LINE PARCEL S 65.00' (OTHER) LINE G (ASSESSOR) REVISIONS (OTHER) R/W 8' PUE G G 1 09/26/25 TITLE REVIEW 0 07/11/25 PRELIMINARY G NO. DATE DESCRIPTION G FND PK/WASH PARCEL PARCEL LINE LINE PARCEL PARCEL LINE LINE (OTHER) (OTHER) E D L A N D E R S U S T R V G I 44007 E Y FND FND PRELIMINARY R E RYAN L. O R PK/WASH FIDLER PK/WASH 4.2 (E) ELECTRCAL EASEMENT REUSE OF DOCUMENT THE IDEAS & DESIGN INCORPORATED HEREON, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RLF CONSULTING, LLC. 55.00' R/W (ASSESSOR) PROJECT No. 2500544 SITE NAME: GOODAZ0284 4.3 (E) ELECTRCAL SITE ADDRESS: EASEMENT PARCEL PARCEL 3875 W. RAY RD. LINE LINE (OTHER) CHANDLER, AZ 85226 NORTH 4.3 SHEET TITLE: 4.3 4.3 (E) ELECTRCAL EASEMENT SURVEY BOUNDARY (E) ELECTRCAL (E) ELECTRCAL EASEMENT EASEMENT SHEET NO. REVISION: PARCEL FND LINE LS-1 BCFL G PARCEL G LINE (E) BUILDING PARCEL G LINE (OTHER) G G 1180.9 TBC 1181.0 TBC 1180.8 TBC 1180.9 TBC 1180.1 TBC (E) GATE PARCEL 1180.4 TBC 1179.8 PV LINE PROPOSED TOWER architecture / project management CENTER OF GEODETIC COORDINATES 10245 E. Via Linda, Scottsdale, AZ 85258 LAT.= 33° 19' 09.396" NORTH 33.319277 NORTH ph: 480 451 9609 fax: 480 451 9608 LON.= 111° 54' 34.393" WEST (E) FACE e mail: corp@ydcoffice.com 111.909554 WEST OF CURB ELEV. @ GROUND =1179.5' 1179.4 TBC 1179.8 TBC FIELD BY: TG 1179.8 TBC 1179.6 TBC 1179.6 TBC DRAWN BY: JMM 1179.9 TBC CHECKED BY: RLF 1180.5 TBC REVISIONS LEGEND BRASS CAP FLUSH PK/WASHER E ELECTRICAL PULL BOX LIGHT POST S SANITARY SEWER MANHOLE 1178.2 PV DRY WELL 1 09/26/25 TITLE REVIEW 5280.00 NG SPOT ELEVATION 1178.5 PV 1179.4 PV 0 07/11/25 PRELIMINARY 1179.1 PV PROPERTY LINE 1178.3 PV PROPERTY LINE (OTHER) NO. DATE DESCRIPTION 1178.6 PV CENTERLINE (E) PARKING LOT 1180.4 TBC 1178.9 PV 1179.4 PV 1179.1 PV 1179.2 PV 1178.9 PV 1179.1 PV E D L A N D E R S U S T R V G I 44007 E Y R E RYAN L. O R PRELIMINARY FIDLER PARCEL LINE REUSE OF DOCUMENT 1179.8 TBC 1179.9 TBC NORTH THE IDEAS & DESIGN INCORPORATED HEREON, AS AN 1179.9 TBC INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RLF CONSULTING, LLC. 1179.8 TBC PROJECT No. 1179.9 TBC 1180.0 TBC 1179.9 TBC 2500544 4.1 (E) 15' SEWER EASEMENT SITE NAME: GOODAZ0284 1180.2 PV 1180.3 PV 1180.1 PV 1180.4 PV SITE ADDRESS: 3875 W. RAY RD. CHANDLER, AZ 85226 1180.8 TBC (E) BACK 1180.9 TBC OF CURB SHEET TITLE: SURVEY DETAIL (E) BUILDING SHEET NO. REVISION: LS-2 SETBACK FROM CENTERLINE OF MONOBROADLEAF TOWER TO NEAREST PROPERTY LINE AT&T NORTHERLY: 32'-8" SOUTHERLY: 357'-4" RAY ROAD N88° 48' 28"E 1355 W. UNIVERSITY DRIVE EASTERLY: 379'-9" 655.46' MESA, AZ 85201 R.O.W. WESTERLY: 40'-8" EXISTING SRP ASSESSOR TRANSFORMER EXISTING COX PEDESTAL 65'-0" #P0402 426683 (POTENTIAL FIBER P.O.C.) POWER P.O.C. PROPERTY LINE 701 PALOMAR AIRPORT RD #160 CARLSBAD, CA 92011 ADJACENT PROPOSED PSTC 12' (P) U.G. ELEC. CONDUIT & PROPERTY LINE WIDE ACCESS / CONDUCTORS FROM (E) UTILITY EASEMENT POWER SOURCE TO (N) TRANSFORMER, ±659'-2" (P) U.G. FIBER CONDUIT FROM FIBER SOURCE TO LOT 3 LOT 5 PROPOSED AT&T ANTENNA ARRAY ZONING: PAD PROPOSED AT&T 3-BAY ZONING: PAD ON PROPOSED PSTC 65' WUC CABINET, ±632'-0" MONOBROADLEAF, (70' O.H.) INSIDE EXISTING PROVIDE A TRAFFIC-RATED YOUNG DESIGN CORP. DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR PSTC COMPOUND, SEE A-3 SHEET BUILDING THEIR LOCATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND JUNCTION BOX FOR POWER DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO FOR CONFIGURATION 32'-8" SETBACK LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/OR FND PK / WASH REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. EXISTING PARKING LOT LIGHT PROVIDE A TRAFFIC-RATED EXISTING POLE, TO BE REMOVED, LED LIGHT BUILDING JUNCTION BOX FOR FIBER TO BE RELOCATED TO S88° 48' 28"W PROJECT: NEW BUILD LEGEND MONOBROADLEAF TRUNK AT 212.70' PTSC SITE NO.: GOODAZ-0284 ABBREVIATIONS: SYMBOLS: EXISTING HEIGHT SITE NAME: MCCLINTOCK (E) - EXISTING (N) - NEW FIRE HYDRANT 379'-9" SETBACK AT&T SITE ID / FA: AZL01562 / 15458390 (F) - FUTURE POWER POLE 40'-8" PD SPD SPD SPD SPD SPD BOX BOX BOX DC DC DC DC DC DC B B R R FIBER FIBER FIBER RTIV RTIV RTIV V V VERTIV VER VER VER VER F USID: 503892 ELECTRIC MANHOLE EXISTING SETBACK LBS PTLC 150 1 ADDRESS: 3875 W. RAY ROAD PUE PUBLIC UTILITY EASEMENT TELCO MANHOLE CHANDLER, AZ 85226 ROW RIGHT OF WAY BUILDING A-2 FND PK / WASH COUNTY: MARICOPA COUNTY PROPOSED PSTC 9' CMU FND PK / WASH BLUE STAKE ELECTRIC PROPERTY LINE BLUE STAKE TELCO WALLED EQUIPMENT EXISTING CONTOUR LINE BLUE STAKE GAS BLUE STAKE WATER COMPOUND SURROUNDING PARKING LOT PROPOSED AT&T EQUIPMENT EXISTING & MONOBROADLEAF TOWER PARKING LOT APN: 301-64-876 ZONE: PAD OWNER: COMMERCIAL RESOURCE INVESTORS III, LLC SIGNS FINAL D 5/1/2026 CMJ MAY ZONING DRAWINGS 1. INSTALL ADDRESS PLACARD NEAR ENTRANCE GATE OF EQUIPMENT AREA LOT 2 LOT 4 (OR FACING STREET OF ASSOCIATED ADDRESS). 90% REVISED ZONING: PAD ZONING: PAD C 8/21/2025 CMJ MAY PRELIMINARY ZD'S LIGHTING 90% PRELIMINARY B 7/23/2025 CMJ MAY 1. ADDITIONAL LIGHTING WILL BE INSTALLED IF REQUIRED BY MUNICIPALITY SETBACK ZD'S FOR SECURITY PURPOSES. LEASE A 6/9/2025 CMJ MAY 2. ALL LIGHTING IS TO BE INSTALLED NO HIGHER THAN 8'-0", (UNLESS EXHIBIT REQUIRED OTHERWISE BY INDIVIDUAL MUNICIPALITY). 357'-4" PROFESSIONAL SEAL 3. ALL LIGHTING WILL BE THAT OF "FULL CUT OFF LENSES". COMPLIANCE 1. ADA COMPLIANCE: FACILITY IS NOT STAFFED AND NOT NORMALLY ONLY OCCUPIED. PRELIMINARY 2. CONTRACTOR IS RESPONSIBLE FOR ERECTING TEMPORARY BARRICADES DRAWINGS AND/OR FENCING TO PROTECT THE SAFETY OF THE PUBLIC DURING CONSTRUCTION. EXISTING EXISTING 21'-0" ZONING BUILDING HIGH BUILDING 3. THE ANTENNAS SHALL NOT INTERFERE WITH ANY EXISTING COMMUNICATION SITES. FOR 4. DEVELOPMENT AND USE OF THIS SITE WILL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES. 5. ALL ITEMS ON THIS DRAWING ARE EXISTING UNLESS OTHERWISE NOTED. YDC PROJECT NUMBER NOTES YDC-11352 1. SITE PLAN RENDERING DERIVED FROM DETAILS PROVIDED FROM ASSESSORS MAP & SITE AUDIT. 2. REFER TO AT&T SPECIFICATIONS FOR ADDITIONAL CARRIER SHEET TITLE INFORMATION/DETAILS. 3. G.C. TO VERIFY EXISTING FIELD CONDITIONS AND DIMENSIONS PRIOR TO N CONSTRUCTION UTILITY SITE PLAN 4. G.C. TO BRING ALL EXISTING AND NEW EQUIPMENT INTO COMPLIANCE WITH GOVERNING CODES. 5. G.C. TO RE-COLORCODE ALL EXISTING AND NEW AT&T COAX TO CURRENT SHEET NUMBER AT&T STANDARDS. A-1.0 22"x34" SCALE: 1" = 20'-0" GENERAL SITE NOTES N.T.S. 2 OVERALL SITE PLAN 1 11"x17" SCALE: 1" = 40'-0" 20' 10' 0" 20' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. AT&T 1355 W. UNIVERSITY DRIVE EXISTING TRASH MESA, AZ 85201 ENCLOSURE BY OTHERS, TO REMAIN UNCHANGED PROPERTY LINE PROPOSED PSTC 12' WIDE ACCESS / UTILITY EASEMENT PROVIDE A 4AB APPROVED FIRE EXTINGUISHER ON INSIDE OF COMPOUND (P) U.G. ELEC. CONDUIT & CONDUCTORS FROM (E) 701 PALOMAR AIRPORT RD #160 POWER SOURCE TO (N) TRANSFORMER, ±659'-2" CARLSBAD, CA 92011 APPROXIMATE LOCATION OF EXISTING PARKING LOT LIGHT POLE, TO BE REMOVED, LUMINAIRE / FIXTURE TO BE RELOCATED TO PROPOSED MONOBROADLEAF TRUNK AT EXISTING HEIGHT PROPOSED PSTC 120/240V 1Ø 3-WIRE, 4-CLIP 200AMP METER & DISCONENCT ON WALL-MOUNTED UNISTRUT TO BE UTILIZED BY AT&T FOR POWER 31'-10" PROPOSED PSTC LEASE AREA / ACCESS & UTILITY EASEMENT (P) U.G. FIBER CONDUIT FROM FIBER SOURCE TO PROPOSED PSTC 9' HIGH CMU SCREEN WALL, PROPOSED AT&T 3-BAY WUC CABINET, ±632'-0" COLOR / TEXTURE TO MATCH EXISTING BUILDING TO SOUTH, W/ PAINTED STUCCO ON TOP, BOTTOM TO BE DECORATIVE ROCK (P) U.G. ELEC. CONDUIT & CONDUCTORS FROM (P) AT&T 5'-0" 7'-4" 5'-4" 10'-0" METER TO EQUIP. LOCATION, ±12'-1" PROPOSED PSTC T.S. ACCESS GATE W/ PAINTED SOLID METAL BACKING, PROPOSED AT&T SPD DC50 COLOR TO MATCH WALL MOUNTED TO SIDE OF WUC, SEE DETAIL 2 ON SHEET D-8 FOR MORE DETAILS PROJECT: NEW BUILD PTSC SITE NO.: GOODAZ-0284 SITE NAME: MCCLINTOCK PROPOSED PSTC U.G. 3"Ø CONDUIT FOR POWER AREA AT&T SITE ID / FA: AZL01562 / 15458390 BETWEEN NEW PAD USID: 503892 MOUNTED TRANSFORMER & LEASE ADDRESS: 3875 W. RAY ROAD 200AMP METER / DISCONNECT 5'-0" 4'-1" 4'-1" 4'-1" CHANDLER, AZ 85226 PSTC WALL PSTC COUNTY: MARICOPA COUNTY SPD PD PD SPD P SP BOX BOX DC DC DC DC B B FIBER R R FIBER V V RTIV VERTIV VER F 1'-4" PROPOSED SCREEN PROPOSED 6'-10" 3'-8" CMU PROPOSED NEQ.15918 VERTIV 10'-8" F2012495 -48 VDC VERTIV XTE 3'-10" SLAB SLAB 13'-1" SLA 601B BATTERY ENCLOSURE W/ (5) BATTERY SHELVES W/ MAX 9'-0" 9'-0" 9'-0" 9'-0" 9'-0" -0 0 PROPOSED AT&T ANTENNA ARRAY CAPACITY OF (6) -48V BATTERY 9 MOUNTED TO APPROVED MOUNTS AREA STRINGS ON CONCRETE SLAB, SLAB ON PROPOSED PSTC 65' (70' O.H.) SEE DETAIL 2 ON SHEET D-3 14'-0" MONOBROADLEAF TREE, SEE A-3 LEASE 4'-0" SHEET FOR CONFIGURATION EXISTING MEDIAN TO BE PROPOSED AT&T [CEQ.54298] VERTIV, D 5/1/2026 FINAL CMJ MAY REMOVED AND REPLACED WITH LBS PTLC 150 F2020030,,,, VERTIV WUC 3-BAY ZONING DRAWINGS PSTC PROPOSED COMPOUND CABINET W/ 6KW HEX 512DC PLANT, SURROUNDED BY A CONCRETE DC HEATERS, (ALL OCCURRENCES), C 8/21/2025 90% REVISED CMJ MAY CURB / LANDSCAPE / 4'-7" 4'-0" 3'-10" 4'-0" MOUNTED TO CONCRETE SLAB, SEE PRELIMINARY ZD'S PROPOSED HARDSCAPE MEDIAN SLAB SLAB DETAIL 1 ON SHEET D-3 WALL 90% PRELIMINARY 2'-6" 3'-8" B 7/23/2025 CMJ MAY ZD'S SCREEN PROPOSED PARKING BUFFER MIN. 34'-7" LANDSCAPE MEDIAN, BOULDERS CMU LEASE A 6/9/2025 CMJ MAY AND LANDLORD APPROVED PSTC EXHIBIT VEGETATION TO SOFTEN & PROTECT COMPOUND PROPOSED PROFESSIONAL SEAL 14'-9" PROPOSED PSTC T.S. ACCESS GATE W/ PAINTED SOLID METAL 4'-8" 5'-4" 5'-5" APN: 301-64-876 BACKING, COLOR TO MATCH ZONING: PAD ONLY ADJACENT WALLS OWNER: COMMERCIAL RESOURCE PRELIMINARY (N) PAD MOUNTED 15'-5" PROPOSED PSTC AREA INVESTORS III, LLC DRAWINGS TRANSFORMER ON CMU SCREEN WALL LEASE CONCRETE PAD ZONING PROPOSED AT&T PTLC PSTC AC PANEL W/ CAMLOK MOUNTED TO WUC PROPOSED PROPOSED AT&T GPS 38'-2" FOR ANTENNA MOUNTED TO PIPE MOUNT ON WUC, SEE DETAIL 1 ON SHEET D-8 PROPERTY LINE ZONING: EXISTING EXISTING YDC PROJECT NUMBER PAD MEDIAN PARKING LOT YDC-11352 SHEET TITLE N ENLARGED COMPOUND SITE PLAN SHEET NUMBER A-2 22"x34" SCALE: 1/4" = 1'-0" ENLARGED COMPOUND SITE PLAN 1 11"x17" SCALE: 1/8" = 1'-0" 4' 3' 2' 1' 0" 4' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. NOTES: 1. NO CHAIN MOUNTS OR AT&T A SUPPORT ARE ALLOWED/ PERMITTED ON AT&T TOWER. 0° SECTOR 2. MONOBROADLEAF BRANCHES 1355 W. UNIVERSITY DRIVE AND LEAVES ARE NOT SHOWN MESA, AZ 85201 FOR CLARITY NEW RAYCAP DC9-48-60-0-24-8C-EV 9'-0" FACE WIDTH TYP. DC/FIBER SURGE PROTECTOR, SEE DETAIL 3 ON SHEET D-8, (2) TOTAL, 4'-0" TYP. 4'-0" TYP. (1) PER ALPHA & BETA SECTORS 2'-6" 2'-6" 1 TYP. 2 TYP. 3 NEW 65' PSTC MONOBROADLEAF TOWER W/ AT&T ANTENNAS (70' OVERALL HEIGHT), BRANCHES AND MIN. 1'-0" LEAVES NOT SHOWN FOR CLARITY NEW RRH'S, (3) PER SECTOR, 5'-0" MIN) ERICSSON 4490 B5/B12A @ POS 1 (2'-0" 3'-10" ERICSSON 4890 B25/B66 @ POS 3 ERICSSON 4494 B14/B29 @ POS 3 701 PALOMAR AIRPORT RD #160 MOUNTED TO BACK TO BACK MOUNTS CARLSBAD, CA 92011 ON V-FRAME PIPES, TYP. OF (9) RRH'S 3 1 NEW AT&T ANTENNA, COMMSCOPE NNHH-65C-R4, @ POS 1, (1) PER SECTOR, TYP. OF (3) ANTENNAS C SECTOR 240° NEW AT&T ANTENNA, ERICSSON AIR 2 2 6472 B77G / B77M, @ POS 2, (1) PER SECTOR, TYP. OF (3) ANTENNAS SECTOR NEW AT&T APPROVED MOUNTING 120° B STRUCTURE, (SITEPRO 1 T3D8-3-A3 OR 1 3 APPROVED EQUIVALENT) PROJECT: NEW BUILD PTSC SITE NO.: GOODAZ-0284 SITE NAME: MCCLINTOCK NEW AT&T ANTENNA, COMMSCOPE AT&T SITE ID / FA: AZL01562 / 15458390 NNH4-65C-R6-V4, @ POS 3, (1) PER USID: 503892 SECTOR, TYP. OF (3) ANTENNAS ADDRESS: 3875 W. RAY ROAD CHANDLER, AZ 85226 N COUNTY: MARICOPA COUNTY ANTENNA DETAILS N.T.S. 4 ANTENNA LAYOUT N.T.S. 2 NEW ANTENNA CONFIGURATION TABLE FINAL D 5/1/2026 CMJ MAY POSITION ZONING DRAWINGS COMMSCOPE RR-B2B-AR (# OR N/A) 1 2 - 3 90% REVISED TOTAL WEIGHT (UNFINISHED) 36 LBS (16.329 Kg) ANTENNA (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE C 8/21/2025 PRELIMINARY ZD'S CMJ MAY NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3 ROUND LEGS 2-3/8" DIA TO 3-1/2" DIA 99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8") 90% PRELIMINARY B 7/23/2025 CMJ MAY FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER ZD'S ALL HARDWARE TO BE AZIMUTH 0° 0° 0° A LEASE TORQUED TO 35 FT-LBS (4) DC TRUNKS A 6/9/2025 CMJ MAY RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0" EXHIBIT SECTOR (2) FIBER TRUNK TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE PROFESSIONAL SEAL TMA - - - ERICSSON 4478 B12A ERICSSON 4890 B25/B66 ERICSSON 4494 B14/B29 RRH ANTENNA (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3 99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8") FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER AZIMUTH 120° 120° 120° B (4) DC TRUNKS RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0" SECTOR (2) FIBER TRUNK TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE TMA - - - - ERICSSON 4478 B12A ERICSSON 4890 B25/B66 RRH ERICSSON 4494 B14/B29 YDC PROJECT NUMBER RRH ORDERED ANTENNA (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE SEPARATELY NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3 YDC-11352 99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8") FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER SHEET TITLE C AZIMUTH 240° 240° 240° (4) DC TRUNKS RR-B2B-AR RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0" SECTOR (2) FIBER TRUNK ANTENNA LAYOUT & MOUNT TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE TMA - - - DETAILS RRH BACK TO ERICSSON 4478 B12A ERICSSON 4890 B25/B66 MOUNTING PIPE BACK MOUNT ERICSSON 4494 B14/B29 RRH SHEET NUMBER BACK TO BACK ANGLE MOUNT A-3 BACK TO BACK MOUNT DETAIL N.T.S. 3 ANTENNA CONFIGURATION TABLE N.T.S. 1 THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. NOTE: NO CHAIN MOUNTS OR SUPPORT ARE AT&T ALLOWED/ PERMITTED ON AT&T TOWER. 1355 W. UNIVERSITY DRIVE MESA, AZ 85201 701 PALOMAR AIRPORT RD #160 CARLSBAD, CA 92011 PROJECT: NEW BUILD PTSC SITE NO.: GOODAZ-0284 SITE NAME: MCCLINTOCK AT&T SITE ID / FA: AZL01562 / 15458390 USID: 503892 ADDRESS: 3875 W. RAY ROAD CHANDLER, AZ 85226 COUNTY: MARICOPA COUNTY FINAL D 5/1/2026 CMJ MAY ZONING DRAWINGS 90% REVISED C 8/21/2025 CMJ MAY PRELIMINARY ZD'S 90% PRELIMINARY B 7/23/2025 CMJ MAY ZD'S EXISTING LED LUMINAIRE, SHALL BE EXISTING LED LUMINAIRE, SHALL BE SALVAGED IF POSSIBLE, OTHERWISE A SALVAGED IF POSSIBLE, OTHERWISE A LEASE REPLACEMENT LUMINAIRE W/ SAME REPLACEMENT LUMINAIRE W/ SAME A 6/9/2025 CMJ MAY EXHIBIT OUTPUT TO BE INSTALLED ON OUTPUT TO BE INSTALLED ON BROADLEAF TOWER AT EXISTING HEIGHT BROADLEAF TOWER AT EXISTING HEIGHT PROFESSIONAL SEAL LOT LOT PARKING PARKING REMOVED REMOVED ONLY PRELIMINARY EXISTING BE EXISTING BE DRAWINGS TO TO ZONING OF POLE OF POLE TOP TOP EXISTING PARKING TO LIGHT EXISTING PARKING TO LIGHT LOT LIGHT POLE & LOT LIGHT POLE & FOR FOUNDATION, TO BE 30'-0" FOUNDATION, TO BE 30'-0" REMOVED REMOVED EXISTING TRASH ENCLOSURE, TO YDC PROJECT NUMBER REMAIN UNCHANGED EXISTING EXISTING YDC-11352 CONCRETE CURB / CONCRETE CURB / PARKING MEDIAN, PARKING MEDIAN, TO BE REMOVED TO BE REMOVED SHEET TITLE EXISTING ELEVATIONS SHEET NUMBER A-3.1 22"x34" SCALE: 3/16" = 1'-0" 22"x34" SCALE: 3/16" = 1'-0" EXISTING SOUTH ELEVATION 2 EXISTING WEST ELEVATION 1 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. NOTE: NO CHAIN MOUNTS OR SUPPORT ARE AT&T ALLOWED/ PERMITTED ON AT&T TOWER. 1355 W. UNIVERSITY DRIVE MESA, AZ 85201 701 PALOMAR AIRPORT RD #160 CARLSBAD, CA 92011 PROPOSED AT&T ANTENNA ARRAY PROPOSED AT&T ANTENNA ARRAY MOUNTED TO APPROVED MOUNTS ON MOUNTED TO APPROVED MOUNTS ON PROPOSED AT&T 65' MONOBROADLEAF PROPOSED AT&T 65' MONOBROADLEAF TOWER (70' OVERALL HEIGHT), SEE A-3 TOWER (70' OVERALL HEIGHT), SEE A-3 SHEET FOR CONFIGURATION SHEET FOR CONFIGURATION 8'-0" 8'-0" PROPOSED AT&T ANTENNA PROJECT: NEW BUILD PROPOSED AT&T ANTENNA SOCKS TO CONCEAL SOCKS TO CONCEAL ANTENNAS FROM VIEW WITHIN PTSC SITE NO.: GOODAZ-0284 ANTENNAS FROM VIEW WITHIN MONO-BROADLEAF TOWER SITE NAME: MCCLINTOCK MONO-BROADLEAF TOWER AT&T SITE ID / FA: AZL01562 / 15458390 USID: 503892 ADDRESS: 3875 W. RAY ROAD HEIGHT) HEIGHT) CHANDLER, AZ 85226 COUNTY: MARICOPA COUNTY PROPOSED AT&T (4) POWER TRUNKS, (2) FIBER TRUNKS, ROUTED (OVERALL (OVERALL UP MONO-BROADLEAF TOWER TOWER TOWER PROPOSED AT&T (4) POWER TRUNKS, (2) FIBER TRUNKS, ROUTED UP MONO-BROADLEAF TOWER ARRAY BRANCHES ARRAY BRANCHES ARRAY ARRAY ARRAY ARRAY MONO-BROADLEAF MONO-BROADLEAF ANTENNA ANTENNA ANTENNA ANTENNA ANTENNA ANTENNA PROPOSED RELOCATED / MONO-BROADLEAF MONO-BROADLEAF REPLACEMENT PARKING LOT LED AT&T AT&T AT&T AT&T PROPOSED RELOCATED / AT&T AT&T FINAL LIGHT MOUNTED AT EXISTING AT&T AT&T D 5/1/2026 CMJ MAY HEIGHT (ON OPPOSITE SIDE), OF REPLACEMENT PARKING LOT OF ZONING DRAWINGS OF LED LIGHT MOUNTED AT OF VERIFY HEIGHT IN FIELD OF OF EXISTING HEIGHT, VERIFY 90% REVISED CENTER TIPS PROPOSED AT&T HEIGHT IN FIELD CENTER TIPS PROPOSED AT&T C 8/21/2025 CMJ MAY PRELIMINARY ZD'S CENTER CENTER RAD PROPOSED OF RAD PROPOSED OF B 7/23/2025 90% PRELIMINARY CMJ MAY PROPOSED RAD PROPOSED RAD PROPOSED ZD'S MONOBROADLEAF FAUX STEEL STEEL BARK CLADDING UP TO PROPOSED TO PROPOSED TO A 6/9/2025 LEASE CMJ MAY BOTTOM BRANCHES OF OF OF OF EXHIBIT PROPOSED PROPOSED 65'-0" TOP 65'-0" TOP TOP PROPOSED NEQ.15918 VERTIV TOP PROFESSIONAL SEAL PROPOSED NEQ.15918 VERTIV LUMINAIRE TO TO F2012495 -48 VDC VERTIV XTE 601B LUMINAIRE TO TO F2012495 -48 VDC VERTIV XTE 601B TO TO BATTERY ENCLOSURE W/ (5) BATTERY TO TO 63'-0" 63'-0" BATTERY ENCLOSURE W/ (5) BATTERY 70'-0" SHELVES W/ MAX CAPACITY OF (6) -48V 70'-0" 61'-0" 65'-0" 61'-0" 65'-0" SHELVES W/ MAX CAPACITY OF (6) -48V BATTERY STRINGS ON CONCRETE BATTERY STRINGS ON CONCRETE SLAB, SEE DETAIL 2 ON SHEET D-3 SLAB, SEE DETAIL 2 ON SHEET D-3 REPLACEMENT PROPOSED TRANSFORMER REPLACEMENT ONLY PROPOSED AT&T DC50 SPD PROPOSED PSTC T.S. ACCESS GATE CABINET MOUNTED TO SIDE INSTALLED ON PROPOSED PRELIMINARY W/ PAINTED SOLID METAL BACKING, OF 3-BAY WUC (BEYOND) CONCRETE PAD NEAR GATE COLOR TO MATCH ADJACENT WALLS / / DRAWINGS PROPOSED PSTC 9' HIGH ZONING PROPOSED PSTC 9' HIGH DECORATIVE DECORATIVE CMU WALLED PROPOSED CMU WALLED COMPOUND W/ 2' OF PROPOSED BRANCHES RELOCATED GPS ANTENNA BRANCHES RELOCATED COMPOUND W/ 2' OF ROCK AT ROCK AT BASE TO MATCH PILLARS ON GPS ANTENNA BASE TO MATCH PILLARS ON MOUNTED TO BUILDING TO SOUTH, FOR FULL MOUNTED TO BUILDING TO SOUTH, FOR FULL PIPE ON WUC SCREENING OF EQUIPMENT PIPE ON WUC OF SCREENING OF EQUIPMENT OF FOR BOTTOM BOTTOM TOP TOP PROPOSED TRANSFORMER EXISTING TRASH PROPOSED 200AMP AT&T INSTALLED ON PROPOSED TO TO ENCLOSURE, TO METER / DISCONNECT ON TO TO CONCRETE PAD NEAR GATE REMAIN UNCHANGED WALL-MOUNTED UNISTRUT WALL 20'-0" 30'-0" 20'-0" 30'-0" YDC PROJECT NUMBER CMU 9'-0" YDC-11352 9'-0" PROPOSED CONCRETE MEDIAN SURROUNDING PROPOSED PSTC EQUIPMENT COMPOUND SHEET TITLE PROPOSED AT&T [CEQ.54298] VERTIV, PROPOSED AT&T F2020030,,,, VERTIV WUC 3-BAY CABINET W/ PTLC AC PANEL W/ 6KW HEX 512DC PLANT, DC HEATERS, (ALL CAMLOK MOUNTED ELEVATIONS OCCURRENCES), MOUNTED TO CONCRETE TO SIDE OF WUC SLAB, SEE DETAIL 1 ON SHEET D-3 PROPOSED CONCRETE MEDIAN SURROUNDING PROPOSED PSTC EQUIPMENT COMPOUND SHEET NUMBER A-4 22"x34" SCALE: 3/16" = 1'-0" 22"x34" SCALE: 3/16" = 1'-0" NEW SOUTH ELEVATION 2 1 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED.