Parking Study

City of Chandler — Study Session (2026-10-12)

View PDF Meeting page

Extracted text (via pymupdf_layout) 42517 characters
June 9, 2026
Sam Gudiño
Public Safety Towers, LLC
Phone: (760)612-9949
E-mail: s.gudino@pstctowers.com
Subject: PSTC Parking Study – Chandler, Arizona
– Southeast Corner
Dear
Mr. Gudiño,
Y2K Engineering has been retained to provide traffic engineering services for the above-referenced project,
located on the southeast corner of Ray Road and McClintock Drive in Chandler, Arizona. This report has
been revised from a previous submittal. The responses to comments received on the previous study are
provided in Attachment A.
The new development is proposed on predeveloped land. The project proposes new communication
towers and associated supporting infrastructure on the project site which will result in the removal of three
existing parking spaces. The existing development includes a shopping center, bowling alley, and a tire retail
store. Figure 1 shows the vicinity of the project and Figure 2 shows the project site.
Figure 1: Vicinity Map
1921 S. Alma School Rd, Ste 204 \ Mesa, AZ 85210 480.696.1701 info@y2keng.com

PSTC Parking Study – Chandler, Arizona
June 2026
Figure 2: Project Site
PROPOSED SITE
The proposed development will be constructed on an existing developed parcel. The current parcel
includes a shopping center, bowling alley, and a tire retail store. The new development proposes new
communication towers and supporting infrastructure located on the northwest side of the existing
parking lot. Figure 3 and Figure 4 shows the location of the proposed tower and supporting infrastructure
and the impacted parking spaces are highlighted in Figure 5.
Page 2

PSTC Parking Study – Chandler, Arizona
June 2026
Figure 3: Site Impact Area
Figure 4: Site Impact Area - Closeup
Page 3

PSTC Parking Study – Chandler, Arizona
June 2026
Figure 5: Project Site, Parking Removal Highlighted
EXISTING PARKING
A survey of existing off-street parking at the existing development was conducted based on aerial imagery.
There are three existing developments that use the parking in the area of this study. The existing
developments include a 35,989 square foot shopping center, a 7,000 square foot tire retail store, and a
bowling alley with 40 lanes. These existing developments currently provide a total of 372 existing parking
spaces.
PARKING EVALUATION
CALCULATED PARKING REQUIREMENTS
Parking requirements were calculated for the existing development using the parking requirements in the
City of Chandler Ordinance 35-1804. Table 1 summarizes the square footage of the existing
developments, per documents accessed through the Maricopa County Assessor website, provided in
Attachment B, and the required sparking spaces for each. Parking for a bowling alley is determined by the
number of lanes in the facility therefore number of lanes per the AMF McRay Plaza Lanes website1, is
reported for that building instead of square footage. Existing parking is shown on the site plan in
Attachment C.
1 https://www.amf.com/location/amf-mcray-plaza-lanes (accessed February 18, 2026)
Page 4

PSTC Parking Study – Chandler, Arizona
June 2026
Table 1: Summary of Calculated Parking Requirements per City of Chandler Ordinance 35-1800
Recommended
Unit Size Parking Land Use Parking Ratio
Parking Spaces
Bowling Alley 40 Lanes Bowling Alley 4/Lane 160
Shopping Center
Shopping Plaza 35,989 SF 5.5/1,000 SF 198
(<10 acres)
Tire Store 7,000 SF Retail Sales 1/250 SF 28
Total 386 Spaces
Based on City of Chandler parking requirements, 386 parking spaces are required for the existing
development. Considering the recommended number of spaces exceeds the provided parking supply (372
spaces), the parking requirements are not met in the existing conditions according to the City of Chander
standards.
PARKING REDUCTION PER CITY OF CHANDLER ORDINANCE
City of Chandler Ordinance 35-1807 provides guidance to determine when parking reductions may be
allowed to encourage more efficient use of parking. The shared parking reduction methodology outlined in
35-1807 is intended to accommodate mixed-use developments or multiple nonresidential uses the uses
operate at different peak times from one another. A Shared Parking Calculations Table is provided in Section
35-1807d and details the expected use of parking spaces for each type of development per day of the week
and time of day. For the purposes of this analysis, the proposed bowling alley is classified under the
“cinema/theater, and live entertainment” land use category in the Shared Parking Calculations Table, and
the strip retail plaza and tire store are classified under the “retail” category.
Table 2 summarizes the results of the calculations for the existing development based on the Shared
Parking Calculations Table found in Section 35-1807d.
Table 2: Summary of Calculated Parking Requirements per Section 35-1807 Parking Reduction
Time of Use
Weekdays Weekends
Unit General Land Use Recommended Parking 12:00 am - 7:00 am - 6:00 pm - 12:00 am - 7:00 am - 6:00 pm -
Classification Spaces Per City of Chandler 7:00 am 6:00 pm 12:00 am 7:00 am 6:00 pm 12:00 am
Bowling Alley Cinema/Theater, and 160 0% 70% 100% 5% 70% 100%
Live Entertainment 0 112 160 8 112 160
Shopping Plaza Retail 198 0% 100% 80% 0% 100% 60%
0 198 158 0 198 119
Tire Store Retail 28 0% 100% 80% 0% 100% 60%
0 28 22 0 28 17
Total Spaces 0 338 341 8 338 296
Based on the parking reduction calculations summarized in the table above, the peak parking demand is
expected to occur during the weekday evening period from 6:00 p.m. to 12:00 a.m., with an estimated
demand of 341 parking spaces.
SUMMARY
The City of Chandler requires a minimum of 386 parking spaces for the existing development per parking
rates provided in Ordinance 35-1804. Ordinance 35-1807 provides that parking requirements may be
reduced based on a parking demand study performed utilizing the City’s approved Shared Parking
Page 5

PSTC Parking Study – Chandler, Arizona
June 2026
methodology where multiple nonresidential uses that operate at different peak times are expected to use
the parking spaces. Utilizing the Shared Parking methodology, the required number of parking spaces may
be reduced to 341 parking spaces while still adequately serving the development.
The development currently provides 372 parking spaces. The proposed communication tower and
associated infrastructure would remove three existing parking spaces, leaving 369 parking spaces to serve
the development. Per the parking calculations described above, 341 parking spaces are the minimum
required to adequately serve the development. The removal of three parking spaces will still provide 28
excess parking spaces when compared to the minimum required parking per City of Chandler Ordinances.
CONCLUSIONS
 The proposed development on the southeast corner of Ray Road and McClintock Drive proposes
new communication towers and supporting infrastructure.
 The proposed development will remove three existing parking spaces.
 The existing site includes 372 parking spaces. The proposed development would reduce available
parking to 369 parking spaces.
 Based on City of Chandler parking requirements, 386 parking spaces are required for the existing
development to obtain an efficient parking capacity. However, when applying the Shared Parking
methodology, the minimum required parking is 341 parking spaces.
 The proposed 369 remaining parking spaces, after the removal of three spaces for the new
communication towers, are anticipated to meet the parking needs of the site based on the shared
parking reduction detailed in the City of Chandler Ordinance 35-1807.
We appreciate the opportunity to prepare this study. Should you have any questions, please feel free to
contact me by email at mgende@y2keng.com.
Sincerely,
Melissa Gende, PE, PTOE, RSP1
Project Manager, Traffic Studies Lead
Attachments
Page 6

PSTC Parking Study – Chandler, Arizona
June 2026
ATTACHMENT A: RESPONSE TO COMMENTS

COMMENT RESPONSES
1st Review
Project: 26-020 PSTC Chandler Parking Study
Project Location Southeast Corner of Ray Road and McClintock Drive Prepared by Y2K Engineering
Agency City of Chandler Date of Report 3/9/2026
Reviewed By Taylor Manemann Responses by Melissa Gende
Date 4/22/2026 Date of Responses 5/6/2026
A = WILL COMPLY C = AGENCY TO EVALUATE
B = CONSULTANT / APPLICANT TO EVALUATE D = REVIEW TEAM RECOMMENDS NO FURTHER ACTION
Comment
No Agency Page # Comment By Comment Disposition Addressed Response / Comment
By
For the purpose of the required parking, the Bowling Alley
Thank you! We used this and it reduced bowling
may use a 5.5/1000 parking calculation if it would result in
alley parking required from 160 to 159 (28,820 sf)
1 COC 4 Taylor Manemann less required parking. If parking at 4 spaces/lane provides D MG
so we decided to leave the 160 since they were so
less required parking then you can continue to use that
close.
ratio instead.
Provide additional justification for parking reduction
through a shared parking evaluation based on time of use.
Parking Reduction Methodology and calculations
Since there is already an existing deficiency and this
2 COC 4 Taylor Manemann A MG added to report per section 35-1087 and Shared
reduction will be increasing that deficiency, additional
Parking Reduction Table provided in 35-1807d.
justification is required. Please see zoning code section 35-
1807.d for reference.
Clarify which parking spaces are being looked at to get to
Additional figure (Figure 3) added to provide
3 COC 5 Taylor Manemann this provided number. Provide a plan clearly outlining A MG
clarity
these spaces
Comment Responses
Page 1 of 1

PSTC Parking Study – Chandler, Arizona
June 2026
ATTACHMENT B: EXISTING BUILDING DIMENSIONS

2/20/26, 10:52 AM Maricopa County Assessor's Office - 30164875
Eddie Cook
Maricopa County Assessor
Sketch Viewer: 301-64-875 | Page: 1
https://mcassessor.maricopa.gov/sketch/30164875/view/1/ 1/1

2/20/26, 10:50 AM Maricopa County Assessor's Office - 30164876
Eddie Cook
Maricopa County Assessor
Sketch Viewer: 301-64-876 | Page: 1
https://mcassessor.maricopa.gov/sketch/30164876/view/1/ 1/1

PSTC Parking Study – Chandler, Arizona
June 2026
ATTACHMENT C: SITE PLAN

CONSULTANT TEAM APPROVALS
CLIENT REPRESENTATIVE AT&T (RF): DATE: AT&T
PUBLIC SAFETY TOWERS COMPANY
701 PALOMAR AIRPORT RD #160 AT&T (CONST.): DATE:
CARLSBAD, CA 92011
CONTACT: SAM GUDINO EMAIL: S.GUDINO@PSTCTOWERS.COM AT&T (S.A.): DATE: 1355 W. UNIVERSITY DRIVE
PHONE: (760) 612-9949 MESA, AZ 85201
LANDLORD: DATE:
PROJECT OWNER
AT&T MOBILITY
1355 W. UNIVERSITY DRIVE
MESA, AZ 85201
CONTACT: DR. ANIL CHERUVU PROJECT DESCRIPTION
PHONE: (602) 625-3973 EMAIL: ac7856@ATT.COM
GROUND SCOPE
PROPERTY OWNER INSTALL A NEW UL LISTED WALK-UP CABINET (W.U.C.) & BACK-UP GENERATOR SUPPORTED BY CONCRETE
COMMERCIAL RESOURCE INVESTORS III, LLC SLABS WITHIN A NEW CMU WALLED COMPOUND TO INCLUDE THE FOLLOWING:
3855 W. RAY ROAD, #3 · (1) NEW [CEQ.54298] VERTIV, F2020030,,,, UL LISTED VERTIV WUC 3-BAY WALK-UP CABINET (W.U.C.) - ON
CHANDLER, AZ 85226 NEW CONCRETE SLAB
· (1) NEW [NEQ.20574] POLAR POWER, INC. 8220-100-D-20-03-V,,,,48 VDC; 20KW; DC GENERATOR; HORIZONTAL
A&E CONSULTANT TEAM ENCLOSURE W/ 54 GALLON FUEL TANK WITH OPV ON NEW CONCRETE SLAB 701 PALOMAR AIRPORT RD #160
YOUNG DESIGN CORP, LLC. · (1) NEW GPS ANTENNA MOUNTED TO WUC PIPE CARLSBAD, CA 92011
10245 E. VIA LINDA · (6) NEW U.G. 4" PVC CONDUIT RUNS FROM WUC SPD BOX TO TOWER
SCOTTSDALE, AZ 85258 PROJECT: NEW BUILD IWM JOB #1: WSANM0039718 (PARENT) · (2) NEW AT&T SCHD 40 PVC 2" Ø U.G. CONDUIT W/ (3) 1.25 Ø INNERDUCTS FROM CARRIER FIBER VAULT TO
CONTACT: MATT YOUNG WUC
PHONE: (480) 451-9608 EMAIL: MATT.YOUNG@YDCOFFICE.COM PTSC SITE NO.: GOODAZ-0284 IWM JOB #2: WSANM0039653 · (2) 2" CONDUITS W/ (2) 4/0s PER CONDUIT FOR WIRING & (1) 1" CONDUIT W/ (3) CAT6s FOR GENERATOR
ALARM
CONTACT: CHRISTIAN JESPERSON SITE NAME: MCCLINTOCK IWM JOB #3: WSANM0039803 · NEW VERTIV DC50 SPD MOUNTED TO WUC
PHONE: (480) 235-2729 EMAIL: CHRISTIAN.JESPERSON@YDCOFFICE.COM · NEW 600AMP METER SERVICE W/ 200AMP METER SOCKET FOR AT&T
AT&T SITE ID / FA: AZL01562 / 15458390 IWM JOB #4: WSANM0039781 · NEW U.G. CONDUITS FOR ELECTRICAL SERVICE
TOWER OWNER · NEW FIBER SITE VAULT
PUBLIC SAFETY TOWERS COMPANY USID: 503892 IWM JOB #5: WSANM0039740 · NEW GROUND RING
701 PALOMAR AIRPORT RD #160 TOWER SCOPE
CARLSBAD, CA 92011 ADDRESS: 3875 W. RAY ROAD IWM JOB #6: WSANM0039700 BY AT&T:
CONTACT: SAM GUDINO · NEW 65'-0" AT&T MONOBROADLEAF TOWER (70' OVERALL HEIGHT)
PHONE: (760) 612-9949 EMAIL: S.GUDINO@PSTCTOWERS.COM CHANDLER, AZ 85226 IWM JOB #7: WSANM0039654 · (1) NEW AT&T APPROVED ANTENNA MOUNTS
· (3) NEW COMMSCOPE NNHH-65C-R4 ANTENNAS, (1) PER SECTOR
IWM JOB #8: WSANM0039628 · (3) NEW ERICSSON AIR 6472 B77G / B77M ANTENNAS, (1) PER SECTOR
· (3) NEW COMMSCOPE NNH4-65C-R6-V4 ANTENNAS, (1) PER SECTOR
IWM JOB #9: WSANM0039627 · (3) NEW ERICSSON 4478 B12A, (1) PER SECTOR
· (3) NEW ERICSSON 4890 B25/B66, (1) PER SECTOR
· (3) NEW ERICSSON 4494 B14/B29, (1) PER SECTOR
DRIVING DIRECTIONS JURISDICTIONAL APPROVAL · (2) 24-PAIR FIBER 36SM TRUNK CABLES, (1) PER SQUID
GENERAL NOTES
· (4) #6 AWG DC PWRT-606-S POWER TRUNK CABLES, (2) PER SQUID
· (2) NEW RAYCAP DC9-48-60-24-8C-EV DC SQUIDS PROJECT: NEW BUILD
CONTRACTOR & CREWS SHALL ABIDE BY AT&T CONSTRUCTION STANDARDS/REQUIREMENTS AS DESCRIBED IN DIRECTIONS: ELECTRICAL SCOPE PTSC SITE NO.: GOODAZ-0284
THE AT&T SAFETY HANDBOOK. · (1) 15A BREAKERS FOR SIAD
SITE NAME: MCCLINTOCK
DEPARTING FROM AT&T OFFICE: 1355 WEST UNIVERSITY DRIVE, MESA, AZ · (2) 20A BREAKER FOR GEN 3 / GEN 4 BBU
OSHA REGULATIONS/STANDARDS SHALL BE REVIEWED & FOLLOWED BY ALL EQUIPMENT INSTALLERS AND 85201-5419: GET ON AZ-101 LOOP S IN TEMPE FROM W. UNIVERSITY DR. · (3) 25A BREAKERS FOR B12A RRHS AT&T SITE ID / FA: AZL01562 / 15458390
TOWER/ROOF TOP CONTRACTORS/SUBCONTRACTORS DURING CONSTRUCTION. FOLLOW AZ-101 LOOP S TO N. PRICE RD IN CHANDLER. TAKE EXIT 59 FROM · (3) 40A BREAKERS FOR INTEGRATED RADIOS USID: 503892
AZ-101 LOOP S. TAKE W. RAY RD TO YOUR DESTINATION. · (3) 50A BREAKERS FOR B14/B29 RRHS
ADDRESS: 3875 W. RAY ROAD
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL FAULTY, INFERIOR AND/OR · (3) 50A BREAKERS FOR B25/B66 RRHS
IMPROPER MATERIALS, DAMAGED GOODS, AND/OR FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE · (2) 60A BREAKERS FOR FUSE PANEL CHANDLER, AZ 85226
PROJECT IS COMPLETE AND ACCEPTED UNDER THIS CONTRACT: UNLESS NOTED OTHERWISE IN THE · INSTALL (8) NEW MARATHON M12V180FTX BATTERIES COUNTY: MARICOPA COUNTY
CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. (EXCEPTION) THE ROOFING SUBCONTRACTOR · WUC CABINET HAS NO HVAC. 6KW 512 DC PLANT W/ DC-POWERED HEAT EXCHANGERS ARE INSTALLED IN
SHALL FURNISH A MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE GENERAL EACH BAY
CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A PERIOD OF TWO (2) YEARS · EMERSON 7100 -48VDC POWER PLANT OUTFITTED WITH (10) HE 2kW -48VDC RECTIFIERS, 58VDC
STARTING AFTER THE DATE OF SUBSTANTIAL COMPLETION OF THE PROJECT, UNLESS OTHERWISE WRITTEN IN CONVERTERS
THE CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. THESE PLANS HAVE BEEN DEVELOPED FOR A NEW TELECOMMUNICATIONS FACILITY OWNED OR LEASED BY
AT&T IN ACCORDANCE WITH THE SCOPE OF WORK PROVIDED BY AT&T.
THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY OF THE OWNER'S EMPLOYEES,
WORKMEN, AND ALL TIMES DURING THE CONSTRUCTION OF THE PROJECT. VICINITY MAP
THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS AND/OR FEES WITH RESPECT SHEET INDEX
TO THE WORK TO COMPLETE THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BE THE OWNER
OR HIS REPRESENTATIVE. CONTRACTOR SHALL OBTAIN PERMIT AND MAKE FINAL PAYMENT FOR SAID
DOCUMENT. SHEET # DESCRIPTION
FINAL
AT&T GC TO VERIFY ALL MEASUREMENTS OF EXISTING CONDUITS FOR FIBER RUN AND ANY POWER RUNS. T-1 TITLE SHEET D 5/1/2026 CMJ MAY
ZONING DRAWINGS
DO NOT SCALE DRAWINGS LS-1 SURVEY BOUNDARY
90% REVISED
C 8/21/2025 CMJ MAY
LS-2 SURVEY DETAIL PRELIMINARY ZD'S
90% PRELIMINARY
B 7/23/2025 CMJ MAY
SITE INFORMATION ZD'S
A-1.0 UTILITY SITE PLAN
DRIVE
LEASE
PROPERTY OWNER: COMMERCIAL RESOURCE A-2 NEW ENLARGED COMPOUND PLAN A 6/9/2025 CMJ MAY
EXHIBIT
INVESTORS III, LLC
3855 W. RAY RD, #3 A-3 ANTENNA LAYOUT & DETAILS
MCCLINTOCK PROFESSIONAL SEAL
CHANDLER, AZ 85226
A-3.1 EXISTING ELEVATIONS
A-4 NEW ELEVATIONS
N.
APPLICANT: PUBLIC SAFETY TOWERS COMPANY
701 PALOMAR AIRPORT RD #160 N
W. RAY ROAD
CARLSBAD, CA 92011 ONLY
CONTACT: SAM GUDINO
PHONE: (760) 612-9949 WINDMILLS PRELIMINARY
BOULEVARD
EMAIL: S.GUDINO@PSTCTOWERS.COM
DRAWINGS
TOWER TYPE: MONOBROADLEAF SITE N.
CALL 811 or (800) 782-5348
ZONING
WWW.ARIZONA811.COM
SITE TYPE: WIRELESS COMMUNICATIONS FACILITY
CONTRACTOR TO CALL TO VERIFY
APN: 301-64-876 AR ZONA UTILITIES AT LEAST TWO WORKING
R
BLUE INC. STAKE, DAYS PRIOR TO DIGGING FOR
LATITUDE 33° 19' 09.396" N
33.319277°
LONGITUDE 111° 54' 34.393" W
APPLICABLE CODES RFDS DATA SUMMARY YDC PROJECT NUMBER
-111.909554°
EXISTING ELEVATION: ±1179.5' SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, DESIGN PACKAGE BASED ON RF DATA SHEET YDC-11352
RFDS NAME: GOODAZ-0284_RFDS_Prelim_2026-04-24.pdf
STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING
RFDS ID: RFDS-24510
EXISTING ZONING: PAD JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED VERSION: 1.0
CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL RFDS DATE: 14/03/2024 UPDATED BY ac7856 ON 24/04/2026
SHEET TITLE
GOVERN THE DESIGN.
CONSTRUCTION TYPE: V-B
SUMMARY OF EQUIPMENT:
1. BUILDING CODE: INTERNATIONAL BUILDING CODE 2024 NUMBER OF SECTORS: . . . . . . . . . . . . . . 3
PROPOSED LEASE AREA: 756.42 SQ FT. (PSTC LEASE AREA)
2. ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2023 NUMBER OF ANTENNAS: . . . . . . . . . . . . . 9
3. LIGHTNING PROTECTION CODE: NFPA 780-2017, LIGHTNING PROTECTION NUMBER OF RRH'S: . . . . . . . . . . . . . . . 9 TITLE SHEET
PROPOSED OCCUPANCY: UNMANNED TELECOMMUNICATIONS FACILITY CODE NUMBER OF FIBER OPTIC CABLES (JUMPERS) . . 1
4. EIA/TIA 222G NUMBER OF FIBER/DC SQUIDS: . . . . . . . . . 2
EXISTING OCCUPANCY: UNMANNED TELECOMMUNICATIONS FACILITY NUMBER OF FIBER TRUNK CABLES . . . . . . . 2
FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS NUMBER OF DC TRUNK CABLES . . . . . . . . . 4
JURISDICTION: CITY OF CHANDLER REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER
REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. SHEET NUMBER
ELECTRICAL PROVIDER: SRP WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A
SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN.
FIBER PROVIDER: COX T-1
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED.

E. WARNER RD.
FLOOD ZONE DESIGNATION SURVEYOR NOTES SCHEDULE B EXCEPTIONS
THE PROPOSED LEASE PREMISES SHOWN HEREON APPEAR TO BE WITHIN FLOOD 1. ALL TITLE INFORMATION IS BASED UPON A COMMITMENT FOR TITLE 4.1 EASEMENT BY COMMERCIAL RESOURCE INVESTORS III, L.L.C., AN RD
ZONE "X" AS DELINEATED ON THE FEDERAL EMERGENCY MANAGEMENT AGENCY INSURANCE PREPARED U.S. TITLE SOLUTIONS, ORDER NO.: UST81269 ARIZONA LIMITED LIABILITY COMPANY TO TUTOR SOUTH TEMPE GROUP, RD.
FIRM MAP NO. 04013C2710L DATED 10/16/2013. EFFECTIVE DATE: 09/23/2025. LLC, AN ARIZONA LIMITED LIABILITY COMPANY, DATED APRIL 23, 2007, RURAL
RECORDED APRIL 24, 2007, IN INSTRUMENT NO: 2007-0475189.
FLOOD ZONE "X" IS DEFINED AS: AREAS DETERMINED TO BE OUTSIDE 500-YEAR 2. SURVEYOR HAS NOT PERFORMED A SEARCH OF PUBLIC RECORDS TO NOTES: SEWER S. E. RAY RD
FLOODPLAIN; DETERMINED TO BE OUTSIDE THE 1% AND 0.2% ANNUAL CHANCE DETERMINE ANY DEFECT IN TITLE. MCCLINTOCK
FLOODPLAINS.
4.2 EASEMENT BY RAY & MCCLINTOCK ASSOCIATES LIMITED PARTNERSHIP,
3. THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD
AN ARIZONA LIMITED PARTNERSHIP TO SALT RIVER PROJECT
INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF E.
AGRICULTURAL IMPROVEMENT AND POWER DISTRICT, A
THE PROPERTY.
POLITICAL SUBDIVISION OF THE STATE OF ARIZONA, DATED FEBRUARY
14, 1994, RECORDED MARCH 01, 1994, IN INSTRUMENT NO: 94-0170395.
PROJECT META DATA 4. SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR E. CHANDLER BLVD.
NOTES: UNDERGROUND ELECTRICAL
1. ELEVATIONS SHOWN HEREON ARE REPRESENTED IN NORTH THEIR LOCATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND
AMERICAN VERTICAL DATUM OF 1988 (NAVD88) ESTABLISHED FROM DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED
GPS DERIVED ELLIPSOID HEIGHTS, APPLYING GEOID 18B SEPARATIONS AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. 4.3 EASEMENT BY RAY & MCCLINTOCK ASSOCIATES LIMITED PARTNERSHIP,
CONSTRAINING TO NGS CORS STATIONS PROVIDED IN THE "ONLINE REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY AN ARIZONA LIMITED PARTNERSHIP TO SALT RIVER PROJECT
POSITIONING USER SERVICE" (OPUS) SOLUTION FOR THIS SPECIFIC OF THE CONTRACTOR. AGRICULTURAL IMPROVEMENT AND POWER DISTRICT, A
POLITICAL SUBDIVISION OF THE STATE OF ARIZONA, ITS SUCCESSORS
SITE.
AND ASSIGNS, DATED JUNE 13, 1991, RECORDED JUNE 21, 1991, IN
2. BEARINGS SHOWED HEREON ARE BASED UPON U.S. STATE PLANE INSTRUMENT NO: 91-286026.
NAD83 COORDINATE SYSTEM ARIZONA STATE PLANE COORDINATE NOTES: UNDERGROUND ELECTRICAL CONDUIT
ZONE CENTRAL, DETERMINED BY GPS OBSERVATIONS.
LESSOR'S LEGAL DESCRIPTION
ITEMS 1 THRU 3, 4.4 - 4.10, 5.1 - 6.2 OF THE CLIENT PROVIDED TITLE
3. FIELD WORK FOR THIS PROJECT WAS PERFORMED ON 07/02/25. LOT 4, RAY & MCCLINTOCK PLAZA, ACCORDING TO BOOK 327 OF MAPS, PAGE 42, REPORT DO NOT CONTAIN GRAPHICALLY PLOTTABLE EASEMENTS,
RECORDS OF MARICOPA COUNTY, ARIZONA.
SETBACKS, RESTRICTIONS OR OTHER ENCUMBRANCES. THE SURVEYOR
CANNOT GUARANTEE THAT NON-PLOTTABLE ENCUMBRANCES DO NOT
EXIST THAT MAY AFFECT THE SUBJECT LEASED PREMISES.
architecture / project management
10245 E. Via Linda, Scottsdale, AZ 85258
ph: 480 451 9609 fax: 480 451 9608
e mail: corp@ydcoffice.com
W W W W W G W W W
W W SS SS SS SS SS SS SS
FND SS SS SS SS S SS SS SS SS
SS SS SS S SS SS SS W
BCFL
WEST RAY ROAD FIELD BY: TG
G
SS
(65' RIGHT-OF-WAY)
W DRAWN BY: JMM
CB FO FO FO
FO FO FO FO FO FO G
SS T H Y D E UGE
ET T UGE UGE UGE UGE UGE PARCEL CHECKED BY: RLF
LINE
PARCEL S 65.00' (OTHER)
LINE G
(ASSESSOR) REVISIONS
(OTHER)
R/W
8' PUE
LOT "3"
G
G
1 09/26/25 TITLE REVIEW
LOT "1" 0 07/11/25 PRELIMINARY
G
LOT "5" NO. DATE DESCRIPTION
G
FND
PK/WASH
PARCEL
PARCEL
LINE
LINE
DRIVE
PARCEL PARCEL
LINE LINE
(OTHER) (OTHER)
E D L A N D
RIGHT-OF-WAY) T E R T I F I C A T E S U R
MCCLINTOK I S jsultzbach@com-serv.com jsultzbach@com-serv.com C E R N O . V E
G 44007 Y
E O
FND FND PRELIMINARY R RYAN L. R
PK/WASH PK/WASH D a FIDLER
t e
S i g n e d
A R I Z O N A , U . S . A .
4.2
(55' (E) ELECTRCAL
NORTH EASEMENT
REUSE OF DOCUMENT
LOT "4" THE IDEAS & DESIGN INCORPORATED HEREON, AS AN
LOT "2" S INSTRUMENT OF PROFESSIONAL SERVICE, IS THE
PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE
USED FOR ANY OTHER PROJECT WITHOUT WRITTEN
AUTHORIZATION OF RLF CONSULTING, LLC.
55.00' R/W SURVEY DETAIL
(ASSESSOR) PROJECT No.
SHEET LS-2
2500544
SITE NAME:
GOODAZ0284
4.3
(E) ELECTRCAL
EASEMENT SITE ADDRESS:
PARCEL PARCEL 3875 W. RAY RD.
LINE LINE
(OTHER) CHANDLER, AZ 85226
NORTH
4.3 SHEET TITLE:
4.3 4.3 (E) ELECTRCAL
EASEMENT SURVEY BOUNDARY
(E) ELECTRCAL (E) ELECTRCAL
EASEMENT EASEMENT
SHEET NO. REVISION:
PARCEL
FND LINE LS-1
BCFL

G
PARCEL
G LINE
(E)
BUILDING
PARCEL G
LINE
(OTHER)
G G
1180.9 TBC
1181.0 TBC 1180.8 TBC
1180.9 TBC
1180.1 TBC
(E) GATE
PARCEL
1180.4 TBC 1179.8 PV
LINE
PROPOSED TOWER architecture / project management
CENTER OF GEODETIC COORDINATES 10245 E. Via Linda, Scottsdale, AZ 85258
LAT.= 33° 19' 09.396" NORTH
33.319277 NORTH ph: 480 451 9609 fax: 480 451 9608
LON.= 111° 54' 34.393" WEST (E) FACE e mail: corp@ydcoffice.com
111.909554 WEST OF CURB
ELEV. @ GROUND =1179.5'
1179.8 TBC
1179.4 TBC FIELD BY: TG
1179.8 TBC
1179.6 TBC
1179.6 TBC DRAWN BY: JMM
1179.9 TBC
CHECKED BY: RLF
1180.5 TBC
REVISIONS
LEGEND
BRASS CAP FLUSH
PK/WASHER
E ELECTRICAL PULL BOX
LIGHT POST
S SANITARY SEWER MANHOLE
1178.2 PV DRY WELL 1 09/26/25 TITLE REVIEW
5280.00 NG SPOT ELEVATION
1178.5 PV 1179.4 PV 0 07/11/25 PRELIMINARY
1179.1 PV PROPERTY LINE
1178.3 PV PROPERTY LINE (OTHER) NO. DATE DESCRIPTION
1178.6 PV
CENTERLINE
(E)
PARKING
LOT
1180.4 TBC
1178.9 PV
1179.1 PV
1179.4 PV 1179.2 PV
1178.9 PV
1179.1 PV E D L A N D
T E R T I F I C A T E S U R
I S jsultzbach@com-serv.com jsultzbach@com-serv.com C E R N O . V E
G 44007 Y
E O
PRELIMINARY R RYAN L. R
D FIDLER
a t
e
S i g n e d
A R I Z O N A , U . S . A .
PARCEL
LINE
REUSE OF DOCUMENT
1179.9 TBC NORTH THE IDEAS & DESIGN INCORPORATED HEREON, AS AN
1179.8 TBC
1179.9 TBC INSTRUMENT OF PROFESSIONAL SERVICE, IS THE
PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE
USED FOR ANY OTHER PROJECT WITHOUT WRITTEN
AUTHORIZATION OF RLF CONSULTING, LLC.
1179.8 TBC
PROJECT No.
1179.9 TBC 1179.9 TBC
1180.0 TBC
2500544
4.1 (E) 15' SEWER
EASEMENT SITE NAME:
GOODAZ0284
1180.2 PV
1180.3 PV
S 1180.1 PV 1180.4 PV SITE ADDRESS:
3875 W. RAY RD.
CHANDLER, AZ 85226
1180.8 TBC (E) BACK
1180.9 TBC
OF CURB
SHEET TITLE:
SURVEY DETAIL
(E)
BUILDING SHEET NO. REVISION:
LS-2

SETBACK FROM CENTERLINE OF MONOBROADLEAF
TOWER TO NEAREST PROPERTY LINE
AT&T
NORTHERLY: 32'-8"
SOUTHERLY: 357'-4" RAY ROAD
N88° 48' 28"E
1355 W. UNIVERSITY DRIVE
655.46'
EASTERLY: 379'-9" MESA, AZ 85201
R.O.W.
40'-8"
WESTERLY: EXISTING SRP ASSESSOR
TRANSFORMER EXISTING COX PEDESTAL
65'-0"
#P0402 426683 (POTENTIAL FIBER P.O.C.)
POWER P.O.C.
PROPERTY LINE
701 PALOMAR AIRPORT RD #160
CARLSBAD, CA 92011
ADJACENT PROPOSED PSTC 12' (P) U.G. ELEC. CONDUIT &
PROPERTY LINE WIDE ACCESS / CONDUCTORS FROM (E)
UTILITY EASEMENT POWER SOURCE TO (N)
TRANSFORMER, ±659'-2"
(P) U.G. FIBER CONDUIT
FROM FIBER SOURCE TO
LOT 3 LOT 5
PROPOSED AT&T 3-BAY
PROPOSED AT&T ANTENNA ARRAY ZONING: PAD ZONING: PAD
WUC CABINET, ±632'-0"
ON PROPOSED PSTC 65'
MONOBROADLEAF, (70' O.H.) INSIDE EXISTING PROVIDE A TRAFFIC-RATED
YOUNG DESIGN CORP. DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR PSTC COMPOUND, SEE A-3 SHEET
THEIR LOCATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND BUILDING JUNCTION BOX FOR POWER
DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO FOR CONFIGURATION 32'-8" SETBACK
LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/OR FND PK / WASH
REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. EXISTING PARKING LOT LIGHT
PROVIDE A TRAFFIC-RATED EXISTING
POLE, TO BE REMOVED, LED LIGHT BUILDING
JUNCTION BOX FOR FIBER
TO BE RELOCATED TO S88° 48' 28"W PROJECT: NEW BUILD
LEGEND
MONOBROADLEAF TRUNK AT 212.70' PTSC SITE NO.: GOODAZ-0284
ABBREVIATIONS: SYMBOLS: EXISTING HEIGHT SITE NAME: MCCLINTOCK
(E) - EXISTING
(N) - NEW FIRE HYDRANT SETBACK AT&T SITE ID / FA: AZL01562 / 15458390
379'-9"
(F) - FUTURE POWER POLE 40'-8" SPD BOX DC FIBER VERTIV USID: 503892
ELECTRIC MANHOLE EXISTING SETBACK LBS PTLC 150 ADDRESS: 3875 W. RAY ROAD
PUE PUBLIC UTILITY EASEMENT 1
TELCO MANHOLE CHANDLER, AZ 85226
ROW RIGHT OF WAY BUILDING
A-2 FND PK / WASH COUNTY: MARICOPA COUNTY
PROPOSED PSTC 9' CMU FND PK / WASH
BLUE STAKE ELECTRIC PROPERTY LINE BLUE STAKE TELCO
WALLED EQUIPMENT EXISTING
CONTOUR LINE BLUE STAKE GAS BLUE STAKE WATER COMPOUND SURROUNDING PARKING LOT
PROPOSED AT&T EQUIPMENT
EXISTING
& MONOBROADLEAF TOWER
APN: 301-64-876 PARKING LOT
ZONE: PAD
OWNER: COMMERCIAL
RESOURCE INVESTORS III, LLC
SIGNS
FINAL
D 5/1/2026 CMJ MAY
ZONING DRAWINGS
1. INSTALL ADDRESS PLACARD NEAR ENTRANCE GATE OF EQUIPMENT AREA
LOT 2 LOT 4
(OR FACING STREET OF ASSOCIATED ADDRESS). 90% REVISED
ZONING: PAD ZONING: PAD C 8/21/2025 CMJ MAY
PRELIMINARY ZD'S
LIGHTING
90% PRELIMINARY
B 7/23/2025 CMJ MAY
1. ADDITIONAL LIGHTING WILL BE INSTALLED IF REQUIRED BY MUNICIPALITY ZD'S
SETBACK
FOR SECURITY PURPOSES.
LEASE
A 6/9/2025 CMJ MAY
2. ALL LIGHTING IS TO BE INSTALLED NO HIGHER THAN 8'-0", (UNLESS EXHIBIT
REQUIRED OTHERWISE BY INDIVIDUAL MUNICIPALITY).
357'-4" PROFESSIONAL SEAL
3. ALL LIGHTING WILL BE THAT OF "FULL CUT OFF LENSES".
COMPLIANCE
1. ADA COMPLIANCE: FACILITY IS NOT STAFFED AND NOT NORMALLY ONLY
OCCUPIED.
PRELIMINARY
2. CONTRACTOR IS RESPONSIBLE FOR ERECTING TEMPORARY BARRICADES DRAWINGS
AND/OR FENCING TO PROTECT THE SAFETY OF THE PUBLIC DURING
CONSTRUCTION. EXISTING EXISTING 21'-0" ZONING
BUILDING HIGH BUILDING
3. THE ANTENNAS SHALL NOT INTERFERE WITH ANY EXISTING
COMMUNICATION SITES.
4. DEVELOPMENT AND USE OF THIS SITE WILL CONFORM TO ALL APPLICABLE FOR
CODES AND ORDINANCES.
5. ALL ITEMS ON THIS DRAWING ARE EXISTING UNLESS OTHERWISE NOTED.
YDC PROJECT NUMBER
NOTES
1. SITE PLAN RENDERING DERIVED FROM DETAILS PROVIDED FROM YDC-11352
ASSESSORS MAP & SITE AUDIT.
2. REFER TO AT&T SPECIFICATIONS FOR ADDITIONAL CARRIER SHEET TITLE
INFORMATION/DETAILS.
3. G.C. TO VERIFY EXISTING FIELD CONDITIONS AND DIMENSIONS PRIOR TO N
CONSTRUCTION
UTILITY SITE PLAN
4. G.C. TO BRING ALL EXISTING AND NEW EQUIPMENT INTO COMPLIANCE WITH
GOVERNING CODES.
5. G.C. TO RE-COLORCODE ALL EXISTING AND NEW AT&T COAX TO CURRENT
AT&T STANDARDS. SHEET NUMBER
A-1.0
GENERAL SITE NOTES N.T.S. 2 OVERALL SITE PLAN 22"x34" SCALE: 1" = 20'-0" 1
11"x17" SCALE: 1" = 40'-0" 20' 10' 0" 20'
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED.

AT&T
1355 W. UNIVERSITY DRIVE
EXISTING TRASH MESA, AZ 85201
ENCLOSURE BY OTHERS, TO
REMAIN UNCHANGED
PROPERTY LINE
PROPOSED PSTC 12' WIDE
ACCESS / UTILITY EASEMENT
PROVIDE A 4AB APPROVED
FIRE EXTINGUISHER ON
701 PALOMAR AIRPORT RD #160
INSIDE OF COMPOUND (P) U.G. ELEC. CONDUIT & CONDUCTORS FROM (E)
POWER SOURCE TO (N) TRANSFORMER, ±659'-2" CARLSBAD, CA 92011
APPROXIMATE LOCATION OF EXISTING PARKING
LOT LIGHT POLE, TO BE REMOVED, LUMINAIRE /
FIXTURE TO BE RELOCATED TO PROPOSED
MONOBROADLEAF TRUNK AT EXISTING HEIGHT
PROPOSED PSTC 120/240V 1Ø 3-WIRE,
4-CLIP 200AMP METER & DISCONENCT ON
WALL-MOUNTED UNISTRUT TO BE
UTILIZED BY AT&T FOR POWER 31'-10" PROPOSED PSTC LEASE AREA / ACCESS & UTILITY EASEMENT
(P) U.G. FIBER CONDUIT FROM FIBER SOURCE TO
PROPOSED PSTC 9' HIGH CMU SCREEN WALL, PROPOSED AT&T 3-BAY WUC CABINET, ±632'-0"
COLOR / TEXTURE TO MATCH EXISTING BUILDING
TO SOUTH, W/ PAINTED STUCCO ON TOP,
BOTTOM TO BE DECORATIVE ROCK
(P) U.G. ELEC. CONDUIT &
5'-0" 7'-4" 5'-4" 10'-0"
CONDUCTORS FROM (P) AT&T
METER TO EQUIP. LOCATION, ±12'-1"
PROPOSED PSTC T.S.
ACCESS GATE W/ PAINTED
SOLID METAL BACKING, PROPOSED AT&T SPD DC50
COLOR TO MATCH WALL MOUNTED TO SIDE OF WUC,
SEE DETAIL 2 ON SHEET D-8
FOR MORE DETAILS PROJECT: NEW BUILD
PTSC SITE NO.: GOODAZ-0284
SITE NAME: MCCLINTOCK
PROPOSED PSTC U.G. 3"Ø
CONDUIT FOR POWER AREA AT&T SITE ID / FA: AZL01562 / 15458390
BETWEEN NEW PAD USID: 503892
MOUNTED TRANSFORMER & LEASE ADDRESS: 3875 W. RAY ROAD
200AMP METER / DISCONNECT 5'-0" 4'-1"
PSTC CHANDLER, AZ 85226
WALL PSTC COUNTY: MARICOPA COUNTY
5'-3" BOX FIBER
SPD DC VERTIV
1'-4" PROPOSED SCREEN
PROPOSED
PROPOSED NEQ.20574 POLAR
3'-9"
POWER, INC. 8220-100-D-20-03-V,,,,48
CMU
VDC; 20KW; DC GENERATOR; 10'-8"
HORIZONTAL ENCLOSURE W/ 54 13'-1"
SLAB
GALLON FUEL TANK WITH OPV ON
PROPOSED CONCRETE SLAB, SEE 9'-0" PROPOSED AT&T ANTENNA ARRAY
DETAIL 2 ON SHEET D-3 SLAB
MOUNTED TO APPROVED MOUNTS
AREA ON PROPOSED PSTC 65' (70' O.H.)
6'-0"
14'-0" MONOBROADLEAF TREE, SEE A-3
SHEET FOR CONFIGURATION
LEASE
FINAL
EXISTING MEDIAN TO BE PROPOSED AT&T [CEQ.54298] VERTIV, D 5/1/2026 CMJ MAY
REMOVED AND REPLACED WITH LBS PTLC 150 F2020030,,,, VERTIV WUC 3-BAY ZONING DRAWINGS
PSTC
PROPOSED COMPOUND CABINET W/ 6KW HEX 512DC PLANT,
90% REVISED
SURROUNDED BY A CONCRETE DC HEATERS, (ALL OCCURRENCES), C 8/21/2025 CMJ MAY
CURB / LANDSCAPE / 3'-10" 4'-0" 3'-10" 4'-0" MOUNTED TO CONCRETE SLAB, SEE PRELIMINARY ZD'S
PROPOSED HARDSCAPE MEDIAN DETAIL 1 ON SHEET D-3
SLAB SLAB 90% PRELIMINARY
2'-6" 3'-8" WALL B 7/23/2025 CMJ MAY
ZD'S
SCREEN
PROPOSED PARKING BUFFER MIN.
34'-7" LEASE
LANDSCAPE MEDIAN, BOULDERS CMU A 6/9/2025 CMJ MAY
AND LANDLORD APPROVED PSTC EXHIBIT
VEGETATION TO SOFTEN &
PROTECT COMPOUND PROPOSED PROFESSIONAL SEAL
14'-9"
PROPOSED PSTC T.S. ACCESS
GATE W/ PAINTED SOLID METAL 4'-8" 5'-4" 5'-5" APN: 301-64-876
BACKING, COLOR TO MATCH
ZONING: PAD ONLY
ADJACENT WALLS
OWNER: COMMERCIAL RESOURCE PRELIMINARY
(N) PAD MOUNTED 15'-5" PROPOSED PSTC AREA INVESTORS III, LLC DRAWINGS
TRANSFORMER ON
CMU SCREEN WALL LEASE
CONCRETE PAD ZONING
PROPOSED AT&T PTLC PSTC
AC PANEL W/ CAMLOK
MOUNTED TO WUC PROPOSED
PROPOSED AT&T GPS 38'-2" FOR
ANTENNA MOUNTED TO
PIPE MOUNT ON WUC, SEE
DETAIL 1 ON SHEET D-8
PROPERTY LINE
ZONING: EXISTING EXISTING YDC PROJECT NUMBER
PAD MEDIAN PARKING LOT
YDC-11352
SHEET TITLE
N
ENLARGED COMPOUND
SITE PLAN
SHEET NUMBER
A-2
ENLARGED COMPOUND SITE PLAN 22"x34" SCALE: 1/4" = 1'-0" 1
11"x17" SCALE: 1/8" = 1'-0" 4' 3' 2' 1' 0" 4'
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED.

NOTES:
1. NO CHAIN MOUNTS OR AT&T
A SUPPORT ARE ALLOWED/
PERMITTED ON AT&T TOWER.
0°
SECTOR 2. MONOBROADLEAF BRANCHES
1355 W. UNIVERSITY DRIVE
AND LEAVES ARE NOT SHOWN
MESA, AZ 85201
FOR CLARITY
NEW RAYCAP DC9-48-60-0-24-8C-EV 9'-0" FACE WIDTH TYP.
DC/FIBER SURGE PROTECTOR, SEE
DETAIL 3 ON SHEET D-8, (2) TOTAL, 4'-0" TYP. 4'-0" TYP.
(1) PER ALPHA & BETA SECTORS
2'-6" 2'-6"
1 TYP. 2 TYP. 3
NEW 65' PSTC MONOBROADLEAF
TOWER W/ AT&T ANTENNAS
(70' OVERALL HEIGHT), BRANCHES AND MIN. 1'-0"
LEAVES NOT SHOWN FOR CLARITY
NEW RRH'S, (3) PER SECTOR,
5'-0" MIN) ERICSSON 4490 B5/B12A @ POS 1
(2'-0" 3'-10" ERICSSON 4890 B25/B66 @ POS 3
ERICSSON 4494 B14/B29 @ POS 3 701 PALOMAR AIRPORT RD #160
MOUNTED TO BACK TO BACK MOUNTS CARLSBAD, CA 92011
ON V-FRAME PIPES, TYP. OF (9) RRH'S
3 1
NEW AT&T ANTENNA, COMMSCOPE
NNHH-65C-R4, @ POS 1, (1) PER
SECTOR, TYP. OF (3) ANTENNAS
C
SECTOR
240° NEW AT&T ANTENNA, ERICSSON AIR
2 2 6472 B77G / B77M, @ POS 2, (1) PER
SECTOR, TYP. OF (3) ANTENNAS
SECTOR
NEW AT&T APPROVED MOUNTING B
120°
STRUCTURE, (SITEPRO 1 T3D8-3-A3 OR 1 3
APPROVED EQUIVALENT)
PROJECT: NEW BUILD
PTSC SITE NO.: GOODAZ-0284
SITE NAME: MCCLINTOCK
NEW AT&T ANTENNA, COMMSCOPE AT&T SITE ID / FA: AZL01562 / 15458390
NNH4-65C-R6-V4, @ POS 3, (1) PER USID: 503892
SECTOR, TYP. OF (3) ANTENNAS
ADDRESS: 3875 W. RAY ROAD
CHANDLER, AZ 85226
N
COUNTY: MARICOPA COUNTY
ANTENNA DETAILS N.T.S. 4 ANTENNA LAYOUT N.T.S. 2
NEW ANTENNA CONFIGURATION TABLE
FINAL
D 5/1/2026 CMJ MAY
POSITION ZONING DRAWINGS
COMMSCOPE RR-B2B-AR (# OR N/A) 1 2 - 3
90% REVISED
TOTAL WEIGHT (UNFINISHED) 36 LBS (16.329 Kg) (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE C 8/21/2025 CMJ MAY
ANTENNA PRELIMINARY ZD'S
NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3
ROUND LEGS 2-3/8" DIA TO 3-1/2" DIA 99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8") 90% PRELIMINARY
B 7/23/2025 CMJ MAY
FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER ZD'S
ALL HARDWARE TO BE AZIMUTH 0° 0° 0°
A LEASE
TORQUED TO 35 FT-LBS (4) DC TRUNKS A 6/9/2025 CMJ MAY
RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0" EXHIBIT
SECTOR (2) FIBER TRUNK
TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE PROFESSIONAL SEAL
TMA - - -
ERICSSON 4478 B12A ERICSSON 4890 B25/B66
ERICSSON 4494 B14/B29
RRH
ANTENNA (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE
NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3
99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8")
FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER
AZIMUTH 120° 120° 120°
B
(4) DC TRUNKS
RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0"
SECTOR (2) FIBER TRUNK
TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE
TMA - - - -
ERICSSON 4478 B12A ERICSSON 4890 B25/B66
ERICSSON 4494 B14/B29
RRH
YDC PROJECT NUMBER
RRH ORDERED ANTENNA (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE
NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3 YDC-11352
SEPARATELY
99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8")
FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER
C AZIMUTH 240° 240° 240° SHEET TITLE
(4) DC TRUNKS
RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0"
RR-B2B-AR SECTOR
(2) FIBER TRUNK ANTENNA LAYOUT &
MOUNT TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE
TMA - - -
DETAILS
RRH BACK TO ERICSSON 4478 B12A ERICSSON 4890 B25/B66
MOUNTING PIPE BACK MOUNT RRH ERICSSON 4494 B14/B29
SHEET NUMBER
BACK TO BACK ANGLE MOUNT
A-3
BACK TO BACK MOUNT DETAIL N.T.S. 3 ANTENNA CONFIGURATION TABLE N.T.S. 1
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED.

NOTE:
NO CHAIN MOUNTS OR SUPPORT ARE
AT&T
ALLOWED/ PERMITTED ON AT&T TOWER.
1355 W. UNIVERSITY DRIVE
MESA, AZ 85201
701 PALOMAR AIRPORT RD #160
CARLSBAD, CA 92011
PROJECT: NEW BUILD
PTSC SITE NO.: GOODAZ-0284
SITE NAME: MCCLINTOCK
AT&T SITE ID / FA: AZL01562 / 15458390
USID: 503892
ADDRESS: 3875 W. RAY ROAD
CHANDLER, AZ 85226
COUNTY: MARICOPA COUNTY
FINAL
D 5/1/2026 CMJ MAY
ZONING DRAWINGS
90% REVISED
C 8/21/2025 CMJ MAY
PRELIMINARY ZD'S
90% PRELIMINARY
B 7/23/2025 CMJ MAY
ZD'S
EXISTING LED LUMINAIRE, SHALL BE EXISTING LED LUMINAIRE, SHALL BE
SALVAGED IF POSSIBLE, OTHERWISE A SALVAGED IF POSSIBLE, OTHERWISE A LEASE
REPLACEMENT LUMINAIRE W/ SAME REPLACEMENT LUMINAIRE W/ SAME A 6/9/2025 CMJ MAY
EXHIBIT
OUTPUT TO BE INSTALLED ON OUTPUT TO BE INSTALLED ON
BROADLEAF TOWER AT EXISTING HEIGHT BROADLEAF TOWER AT EXISTING HEIGHT
PROFESSIONAL SEAL
LOT LOT
PARKING PARKING
REMOVED REMOVED ONLY
PRELIMINARY
EXISTING BE EXISTING BE DRAWINGS
TO TO
ZONING
OF POLE OF POLE
TOP TOP
LIGHT LIGHT
EXISTING PARKING TO EXISTING PARKING TO
FOR
LOT LIGHT POLE & LOT LIGHT POLE &
FOUNDATION, TO BE 30'-0" FOUNDATION, TO BE 30'-0"
REMOVED REMOVED
EXISTING TRASH
ENCLOSURE, TO YDC PROJECT NUMBER
REMAIN UNCHANGED
EXISTING EXISTING YDC-11352
CONCRETE CURB / CONCRETE CURB /
PARKING MEDIAN, PARKING MEDIAN,
TO BE REMOVED TO BE REMOVED
SHEET TITLE
EXISTING ELEVATIONS
SHEET NUMBER
A-3.1
22"x34" SCALE: 3/16" = 1'-0" 22"x34" SCALE: 3/16" = 1'-0"
EXISTING SOUTH ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 2 EXISTING WEST ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 1
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED.

NOTE:
NO CHAIN MOUNTS OR SUPPORT ARE
AT&T
ALLOWED/ PERMITTED ON AT&T TOWER.
1355 W. UNIVERSITY DRIVE
MESA, AZ 85201
701 PALOMAR AIRPORT RD #160
CARLSBAD, CA 92011
PROPOSED AT&T ANTENNA ARRAY
MOUNTED TO APPROVED MOUNTS ON
PROPOSED AT&T ANTENNA ARRAY
PROPOSED AT&T 65' MONOBROADLEAF
MOUNTED TO APPROVED MOUNTS ON
TOWER (70' OVERALL HEIGHT), SEE A-3
PROPOSED AT&T 65' MONOBROADLEAF
SHEET FOR CONFIGURATION
TOWER (70' OVERALL HEIGHT), SEE A-3
SHEET FOR CONFIGURATION
8'-0"
8'-0"
PROPOSED AT&T ANTENNA
PROJECT: NEW BUILD
SOCKS TO CONCEAL
PROPOSED AT&T ANTENNA ANTENNAS FROM VIEW WITHIN PTSC SITE NO.: GOODAZ-0284
SOCKS TO CONCEAL
MONO-BROADLEAF TOWER SITE NAME: MCCLINTOCK
ANTENNAS FROM VIEW WITHIN
MONO-BROADLEAF TOWER AT&T SITE ID / FA: AZL01562 / 15458390
USID: 503892
ADDRESS: 3875 W. RAY ROAD
HEIGHT) HEIGHT) CHANDLER, AZ 85226
COUNTY: MARICOPA COUNTY
PROPOSED AT&T (4) POWER
TRUNKS, (2) FIBER TRUNKS, ROUTED (OVERALL
(OVERALL
UP MONO-BROADLEAF TOWER
TOWER TOWER
PROPOSED AT&T (4)
POWER TRUNKS, (2) FIBER
TRUNKS, ROUTED UP BRANCHES
ARRAY BRANCHES ARRAY
MONO-BROADLEAF TOWER ARRAY ARRAY
ARRAY ARRAY
MONO-BROADLEAF MONO-BROADLEAF
ANTENNA ANTENNA
ANTENNA ANTENNA
ANTENNA ANTENNA
PROPOSED RELOCATED / MONO-BROADLEAF MONO-BROADLEAF
REPLACEMENT PARKING LOT LED AT&T AT&T AT&T PROPOSED RELOCATED / AT&T AT&T AT&T FINAL
LIGHT MOUNTED AT EXISTING AT&T AT&T D 5/1/2026 CMJ MAY
OF REPLACEMENT PARKING LOT OF ZONING DRAWINGS
HEIGHT (ON OPPOSITE SIDE), OF LED LIGHT MOUNTED AT OF
VERIFY HEIGHT IN FIELD OF OF 90% REVISED
EXISTING HEIGHT, VERIFY
CENTER TIPS PROPOSED CENTER TIPS PROPOSED AT&T C 8/21/2025 CMJ MAY
AT&T HEIGHT IN FIELD PRELIMINARY ZD'S
CENTER CENTER
90% PRELIMINARY
RAD PROPOSED OF RAD PROPOSED OF B 7/23/2025 CMJ MAY
PROPOSED RAD PROPOSED RAD PROPOSED ZD'S
MONOBROADLEAF FAUX STEEL STEEL
LEASE
BARK CLADDING UP TO PROPOSED TO PROPOSED TO A 6/9/2025 CMJ MAY
BOTTOM BRANCHES PROPOSED OF OF PROPOSED OF OF EXHIBIT
65'-0" PROPOSED NEQ.20574 POLAR POWER, 65'-0"
PROPOSED NEQ.20574 POLAR POWER, TOP TOP INC. 8220-100-D-20-03-V,,,,48 VDC; TOP TOP PROFESSIONAL SEAL
TO TO
INC. 8220-100-D-20-03-V,,,,48 VDC; LUMINAIRE TO 20KW; DC GENERATOR; HORIZONTAL LUMINAIRE TO
TO TO TO TO
20KW; DC GENERATOR; HORIZONTAL 63'-0" ENCLOSURE W/ 54 GALLON FUEL TANK 63'-0"
ENCLOSURE W/ 54 GALLON FUEL TANK 61'-0" 65'-0" 70'-0" WITH OPV ON PROPOSED CONCRETE 61'-0" 65'-0" 70'-0"
WITH OPV ON PROPOSED CONCRETE SLAB, SEE DETAIL 2 ON SHEET D-3
SLAB, SEE DETAIL 2 ON SHEET D-3
REPLACEMENT PROPOSED TRANSFORMER REPLACEMENT ONLY
PROPOSED PSTC T.S. ACCESS GATE PROPOSED AT&T DC50 SPD
W/ PAINTED SOLID METAL BACKING, CABINET MOUNTED TO SIDE INSTALLED ON PROPOSED PRELIMINARY
COLOR TO MATCH ADJACENT WALLS OF 3-BAY WUC (BEYOND) CONCRETE PAD NEAR GATE
/ / DRAWINGS
PROPOSED PSTC 9' HIGH DECORATIVE PROPOSED PSTC 9' HIGH ZONING
PROPOSED
CMU WALLED COMPOUND W/ 2' OF BRANCHES RELOCATED DECORATIVE CMU WALLED BRANCHES RELOCATED
PROPOSED GPS ANTENNA
ROCK AT BASE TO MATCH PILLARS ON COMPOUND W/ 2' OF ROCK AT
GPS ANTENNA MOUNTED TO
BUILDING TO SOUTH, FOR FULL BASE TO MATCH PILLARS ON
MOUNTED TO PIPE ON WUC
SCREENING OF EQUIPMENT BUILDING TO SOUTH, FOR FULL
PIPE ON WUC OF SCREENING OF EQUIPMENT OF FOR
BOTTOM BOTTOM
TOP TOP
EXISTING TRASH PROPOSED 200AMP AT&T
PROPOSED TRANSFORMER TO TO ENCLOSURE, TO METER / DISCONNECT ON TO TO
INSTALLED ON PROPOSED
WALL REMAIN UNCHANGED WALL-MOUNTED UNISTRUT
CONCRETE PAD NEAR GATE 20'-0" 30'-0" 20'-0" 30'-0" YDC PROJECT NUMBER
CMU 9'-0"
YDC-11352
9'-0" PROPOSED CONCRETE
MEDIAN SURROUNDING
PROPOSED PSTC
EQUIPMENT COMPOUND SHEET TITLE
PROPOSED AT&T [CEQ.54298] VERTIV, PROPOSED AT&T
F2020030,,,, VERTIV WUC 3-BAY CABINET W/ PTLC AC PANEL W/
6KW HEX 512DC PLANT, DC HEATERS, (ALL CAMLOK MOUNTED
ELEVATIONS
OCCURRENCES), MOUNTED TO CONCRETE TO SIDE OF WUC
SLAB, SEE DETAIL 1 ON SHEET D-3
PROPOSED CONCRETE
MEDIAN SURROUNDING
PROPOSED PSTC
EQUIPMENT COMPOUND SHEET NUMBER
A-4
22"x34" SCALE: 3/16" = 1'-0" 22"x34" SCALE: 3/16" = 1'-0"
NEW SOUTH ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 2 NEW WEST ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 1
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED.