Extracted text (via pymupdf_layout)
42517 characters
June 9, 2026 Sam Gudiño Public Safety Towers, LLC Phone: (760)612-9949 E-mail: s.gudino@pstctowers.com Subject: PSTC Parking Study – Chandler, Arizona – Southeast Corner Dear Mr. Gudiño, Y2K Engineering has been retained to provide traffic engineering services for the above-referenced project, located on the southeast corner of Ray Road and McClintock Drive in Chandler, Arizona. This report has been revised from a previous submittal. The responses to comments received on the previous study are provided in Attachment A. The new development is proposed on predeveloped land. The project proposes new communication towers and associated supporting infrastructure on the project site which will result in the removal of three existing parking spaces. The existing development includes a shopping center, bowling alley, and a tire retail store. Figure 1 shows the vicinity of the project and Figure 2 shows the project site. Figure 1: Vicinity Map 1921 S. Alma School Rd, Ste 204 \ Mesa, AZ 85210 480.696.1701 info@y2keng.com PSTC Parking Study – Chandler, Arizona June 2026 Figure 2: Project Site PROPOSED SITE The proposed development will be constructed on an existing developed parcel. The current parcel includes a shopping center, bowling alley, and a tire retail store. The new development proposes new communication towers and supporting infrastructure located on the northwest side of the existing parking lot. Figure 3 and Figure 4 shows the location of the proposed tower and supporting infrastructure and the impacted parking spaces are highlighted in Figure 5. Page 2 PSTC Parking Study – Chandler, Arizona June 2026 Figure 3: Site Impact Area Figure 4: Site Impact Area - Closeup Page 3 PSTC Parking Study – Chandler, Arizona June 2026 Figure 5: Project Site, Parking Removal Highlighted EXISTING PARKING A survey of existing off-street parking at the existing development was conducted based on aerial imagery. There are three existing developments that use the parking in the area of this study. The existing developments include a 35,989 square foot shopping center, a 7,000 square foot tire retail store, and a bowling alley with 40 lanes. These existing developments currently provide a total of 372 existing parking spaces. PARKING EVALUATION CALCULATED PARKING REQUIREMENTS Parking requirements were calculated for the existing development using the parking requirements in the City of Chandler Ordinance 35-1804. Table 1 summarizes the square footage of the existing developments, per documents accessed through the Maricopa County Assessor website, provided in Attachment B, and the required sparking spaces for each. Parking for a bowling alley is determined by the number of lanes in the facility therefore number of lanes per the AMF McRay Plaza Lanes website1, is reported for that building instead of square footage. Existing parking is shown on the site plan in Attachment C. 1 https://www.amf.com/location/amf-mcray-plaza-lanes (accessed February 18, 2026) Page 4 PSTC Parking Study – Chandler, Arizona June 2026 Table 1: Summary of Calculated Parking Requirements per City of Chandler Ordinance 35-1800 Recommended Unit Size Parking Land Use Parking Ratio Parking Spaces Bowling Alley 40 Lanes Bowling Alley 4/Lane 160 Shopping Center Shopping Plaza 35,989 SF 5.5/1,000 SF 198 (<10 acres) Tire Store 7,000 SF Retail Sales 1/250 SF 28 Total 386 Spaces Based on City of Chandler parking requirements, 386 parking spaces are required for the existing development. Considering the recommended number of spaces exceeds the provided parking supply (372 spaces), the parking requirements are not met in the existing conditions according to the City of Chander standards. PARKING REDUCTION PER CITY OF CHANDLER ORDINANCE City of Chandler Ordinance 35-1807 provides guidance to determine when parking reductions may be allowed to encourage more efficient use of parking. The shared parking reduction methodology outlined in 35-1807 is intended to accommodate mixed-use developments or multiple nonresidential uses the uses operate at different peak times from one another. A Shared Parking Calculations Table is provided in Section 35-1807d and details the expected use of parking spaces for each type of development per day of the week and time of day. For the purposes of this analysis, the proposed bowling alley is classified under the “cinema/theater, and live entertainment” land use category in the Shared Parking Calculations Table, and the strip retail plaza and tire store are classified under the “retail” category. Table 2 summarizes the results of the calculations for the existing development based on the Shared Parking Calculations Table found in Section 35-1807d. Table 2: Summary of Calculated Parking Requirements per Section 35-1807 Parking Reduction Time of Use Weekdays Weekends Unit General Land Use Recommended Parking 12:00 am - 7:00 am - 6:00 pm - 12:00 am - 7:00 am - 6:00 pm - Classification Spaces Per City of Chandler 7:00 am 6:00 pm 12:00 am 7:00 am 6:00 pm 12:00 am Bowling Alley Cinema/Theater, and 160 0% 70% 100% 5% 70% 100% Live Entertainment 0 112 160 8 112 160 Shopping Plaza Retail 198 0% 100% 80% 0% 100% 60% 0 198 158 0 198 119 Tire Store Retail 28 0% 100% 80% 0% 100% 60% 0 28 22 0 28 17 Total Spaces 0 338 341 8 338 296 Based on the parking reduction calculations summarized in the table above, the peak parking demand is expected to occur during the weekday evening period from 6:00 p.m. to 12:00 a.m., with an estimated demand of 341 parking spaces. SUMMARY The City of Chandler requires a minimum of 386 parking spaces for the existing development per parking rates provided in Ordinance 35-1804. Ordinance 35-1807 provides that parking requirements may be reduced based on a parking demand study performed utilizing the City’s approved Shared Parking Page 5 PSTC Parking Study – Chandler, Arizona June 2026 methodology where multiple nonresidential uses that operate at different peak times are expected to use the parking spaces. Utilizing the Shared Parking methodology, the required number of parking spaces may be reduced to 341 parking spaces while still adequately serving the development. The development currently provides 372 parking spaces. The proposed communication tower and associated infrastructure would remove three existing parking spaces, leaving 369 parking spaces to serve the development. Per the parking calculations described above, 341 parking spaces are the minimum required to adequately serve the development. The removal of three parking spaces will still provide 28 excess parking spaces when compared to the minimum required parking per City of Chandler Ordinances. CONCLUSIONS The proposed development on the southeast corner of Ray Road and McClintock Drive proposes new communication towers and supporting infrastructure. The proposed development will remove three existing parking spaces. The existing site includes 372 parking spaces. The proposed development would reduce available parking to 369 parking spaces. Based on City of Chandler parking requirements, 386 parking spaces are required for the existing development to obtain an efficient parking capacity. However, when applying the Shared Parking methodology, the minimum required parking is 341 parking spaces. The proposed 369 remaining parking spaces, after the removal of three spaces for the new communication towers, are anticipated to meet the parking needs of the site based on the shared parking reduction detailed in the City of Chandler Ordinance 35-1807. We appreciate the opportunity to prepare this study. Should you have any questions, please feel free to contact me by email at mgende@y2keng.com. Sincerely, Melissa Gende, PE, PTOE, RSP1 Project Manager, Traffic Studies Lead Attachments Page 6 PSTC Parking Study – Chandler, Arizona June 2026 ATTACHMENT A: RESPONSE TO COMMENTS COMMENT RESPONSES 1st Review Project: 26-020 PSTC Chandler Parking Study Project Location Southeast Corner of Ray Road and McClintock Drive Prepared by Y2K Engineering Agency City of Chandler Date of Report 3/9/2026 Reviewed By Taylor Manemann Responses by Melissa Gende Date 4/22/2026 Date of Responses 5/6/2026 A = WILL COMPLY C = AGENCY TO EVALUATE B = CONSULTANT / APPLICANT TO EVALUATE D = REVIEW TEAM RECOMMENDS NO FURTHER ACTION Comment No Agency Page # Comment By Comment Disposition Addressed Response / Comment By For the purpose of the required parking, the Bowling Alley Thank you! We used this and it reduced bowling may use a 5.5/1000 parking calculation if it would result in alley parking required from 160 to 159 (28,820 sf) 1 COC 4 Taylor Manemann less required parking. If parking at 4 spaces/lane provides D MG so we decided to leave the 160 since they were so less required parking then you can continue to use that close. ratio instead. Provide additional justification for parking reduction through a shared parking evaluation based on time of use. Parking Reduction Methodology and calculations Since there is already an existing deficiency and this 2 COC 4 Taylor Manemann A MG added to report per section 35-1087 and Shared reduction will be increasing that deficiency, additional Parking Reduction Table provided in 35-1807d. justification is required. Please see zoning code section 35- 1807.d for reference. Clarify which parking spaces are being looked at to get to Additional figure (Figure 3) added to provide 3 COC 5 Taylor Manemann this provided number. Provide a plan clearly outlining A MG clarity these spaces Comment Responses Page 1 of 1 PSTC Parking Study – Chandler, Arizona June 2026 ATTACHMENT B: EXISTING BUILDING DIMENSIONS 2/20/26, 10:52 AM Maricopa County Assessor's Office - 30164875 Eddie Cook Maricopa County Assessor Sketch Viewer: 301-64-875 | Page: 1 https://mcassessor.maricopa.gov/sketch/30164875/view/1/ 1/1 2/20/26, 10:50 AM Maricopa County Assessor's Office - 30164876 Eddie Cook Maricopa County Assessor Sketch Viewer: 301-64-876 | Page: 1 https://mcassessor.maricopa.gov/sketch/30164876/view/1/ 1/1 PSTC Parking Study – Chandler, Arizona June 2026 ATTACHMENT C: SITE PLAN CONSULTANT TEAM APPROVALS CLIENT REPRESENTATIVE AT&T (RF): DATE: AT&T PUBLIC SAFETY TOWERS COMPANY 701 PALOMAR AIRPORT RD #160 AT&T (CONST.): DATE: CARLSBAD, CA 92011 CONTACT: SAM GUDINO EMAIL: S.GUDINO@PSTCTOWERS.COM AT&T (S.A.): DATE: 1355 W. UNIVERSITY DRIVE PHONE: (760) 612-9949 MESA, AZ 85201 LANDLORD: DATE: PROJECT OWNER AT&T MOBILITY 1355 W. UNIVERSITY DRIVE MESA, AZ 85201 CONTACT: DR. ANIL CHERUVU PROJECT DESCRIPTION PHONE: (602) 625-3973 EMAIL: ac7856@ATT.COM GROUND SCOPE PROPERTY OWNER INSTALL A NEW UL LISTED WALK-UP CABINET (W.U.C.) & BACK-UP GENERATOR SUPPORTED BY CONCRETE COMMERCIAL RESOURCE INVESTORS III, LLC SLABS WITHIN A NEW CMU WALLED COMPOUND TO INCLUDE THE FOLLOWING: 3855 W. RAY ROAD, #3 · (1) NEW [CEQ.54298] VERTIV, F2020030,,,, UL LISTED VERTIV WUC 3-BAY WALK-UP CABINET (W.U.C.) - ON CHANDLER, AZ 85226 NEW CONCRETE SLAB · (1) NEW [NEQ.20574] POLAR POWER, INC. 8220-100-D-20-03-V,,,,48 VDC; 20KW; DC GENERATOR; HORIZONTAL A&E CONSULTANT TEAM ENCLOSURE W/ 54 GALLON FUEL TANK WITH OPV ON NEW CONCRETE SLAB 701 PALOMAR AIRPORT RD #160 YOUNG DESIGN CORP, LLC. · (1) NEW GPS ANTENNA MOUNTED TO WUC PIPE CARLSBAD, CA 92011 10245 E. VIA LINDA · (6) NEW U.G. 4" PVC CONDUIT RUNS FROM WUC SPD BOX TO TOWER SCOTTSDALE, AZ 85258 PROJECT: NEW BUILD IWM JOB #1: WSANM0039718 (PARENT) · (2) NEW AT&T SCHD 40 PVC 2" Ø U.G. CONDUIT W/ (3) 1.25 Ø INNERDUCTS FROM CARRIER FIBER VAULT TO CONTACT: MATT YOUNG WUC PHONE: (480) 451-9608 EMAIL: MATT.YOUNG@YDCOFFICE.COM PTSC SITE NO.: GOODAZ-0284 IWM JOB #2: WSANM0039653 · (2) 2" CONDUITS W/ (2) 4/0s PER CONDUIT FOR WIRING & (1) 1" CONDUIT W/ (3) CAT6s FOR GENERATOR ALARM CONTACT: CHRISTIAN JESPERSON SITE NAME: MCCLINTOCK IWM JOB #3: WSANM0039803 · NEW VERTIV DC50 SPD MOUNTED TO WUC PHONE: (480) 235-2729 EMAIL: CHRISTIAN.JESPERSON@YDCOFFICE.COM · NEW 600AMP METER SERVICE W/ 200AMP METER SOCKET FOR AT&T AT&T SITE ID / FA: AZL01562 / 15458390 IWM JOB #4: WSANM0039781 · NEW U.G. CONDUITS FOR ELECTRICAL SERVICE TOWER OWNER · NEW FIBER SITE VAULT PUBLIC SAFETY TOWERS COMPANY USID: 503892 IWM JOB #5: WSANM0039740 · NEW GROUND RING 701 PALOMAR AIRPORT RD #160 TOWER SCOPE CARLSBAD, CA 92011 ADDRESS: 3875 W. RAY ROAD IWM JOB #6: WSANM0039700 BY AT&T: CONTACT: SAM GUDINO · NEW 65'-0" AT&T MONOBROADLEAF TOWER (70' OVERALL HEIGHT) PHONE: (760) 612-9949 EMAIL: S.GUDINO@PSTCTOWERS.COM CHANDLER, AZ 85226 IWM JOB #7: WSANM0039654 · (1) NEW AT&T APPROVED ANTENNA MOUNTS · (3) NEW COMMSCOPE NNHH-65C-R4 ANTENNAS, (1) PER SECTOR IWM JOB #8: WSANM0039628 · (3) NEW ERICSSON AIR 6472 B77G / B77M ANTENNAS, (1) PER SECTOR · (3) NEW COMMSCOPE NNH4-65C-R6-V4 ANTENNAS, (1) PER SECTOR IWM JOB #9: WSANM0039627 · (3) NEW ERICSSON 4478 B12A, (1) PER SECTOR · (3) NEW ERICSSON 4890 B25/B66, (1) PER SECTOR · (3) NEW ERICSSON 4494 B14/B29, (1) PER SECTOR DRIVING DIRECTIONS JURISDICTIONAL APPROVAL · (2) 24-PAIR FIBER 36SM TRUNK CABLES, (1) PER SQUID GENERAL NOTES · (4) #6 AWG DC PWRT-606-S POWER TRUNK CABLES, (2) PER SQUID · (2) NEW RAYCAP DC9-48-60-24-8C-EV DC SQUIDS PROJECT: NEW BUILD CONTRACTOR & CREWS SHALL ABIDE BY AT&T CONSTRUCTION STANDARDS/REQUIREMENTS AS DESCRIBED IN DIRECTIONS: ELECTRICAL SCOPE PTSC SITE NO.: GOODAZ-0284 THE AT&T SAFETY HANDBOOK. · (1) 15A BREAKERS FOR SIAD SITE NAME: MCCLINTOCK DEPARTING FROM AT&T OFFICE: 1355 WEST UNIVERSITY DRIVE, MESA, AZ · (2) 20A BREAKER FOR GEN 3 / GEN 4 BBU OSHA REGULATIONS/STANDARDS SHALL BE REVIEWED & FOLLOWED BY ALL EQUIPMENT INSTALLERS AND 85201-5419: GET ON AZ-101 LOOP S IN TEMPE FROM W. UNIVERSITY DR. · (3) 25A BREAKERS FOR B12A RRHS AT&T SITE ID / FA: AZL01562 / 15458390 TOWER/ROOF TOP CONTRACTORS/SUBCONTRACTORS DURING CONSTRUCTION. FOLLOW AZ-101 LOOP S TO N. PRICE RD IN CHANDLER. TAKE EXIT 59 FROM · (3) 40A BREAKERS FOR INTEGRATED RADIOS USID: 503892 AZ-101 LOOP S. TAKE W. RAY RD TO YOUR DESTINATION. · (3) 50A BREAKERS FOR B14/B29 RRHS ADDRESS: 3875 W. RAY ROAD THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REMEDY ALL FAULTY, INFERIOR AND/OR · (3) 50A BREAKERS FOR B25/B66 RRHS IMPROPER MATERIALS, DAMAGED GOODS, AND/OR FAULTY WORKMANSHIP FOR ONE (1) YEAR AFTER THE · (2) 60A BREAKERS FOR FUSE PANEL CHANDLER, AZ 85226 PROJECT IS COMPLETE AND ACCEPTED UNDER THIS CONTRACT: UNLESS NOTED OTHERWISE IN THE · INSTALL (8) NEW MARATHON M12V180FTX BATTERIES COUNTY: MARICOPA COUNTY CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. (EXCEPTION) THE ROOFING SUBCONTRACTOR · WUC CABINET HAS NO HVAC. 6KW 512 DC PLANT W/ DC-POWERED HEAT EXCHANGERS ARE INSTALLED IN SHALL FURNISH A MAINTENANCE AGREEMENT FOR ALL WORK DONE, COSIGNED BY THE GENERAL EACH BAY CONTRACTOR, TO MAINTAIN THE ROOFING IN A WATERTIGHT CONDITION FOR A PERIOD OF TWO (2) YEARS · EMERSON 7100 -48VDC POWER PLANT OUTFITTED WITH (10) HE 2kW -48VDC RECTIFIERS, 58VDC STARTING AFTER THE DATE OF SUBSTANTIAL COMPLETION OF THE PROJECT, UNLESS OTHERWISE WRITTEN IN CONVERTERS THE CONTRACT BETWEEN THE OWNER AND THE CONTRACTOR. THESE PLANS HAVE BEEN DEVELOPED FOR A NEW TELECOMMUNICATIONS FACILITY OWNED OR LEASED BY AT&T IN ACCORDANCE WITH THE SCOPE OF WORK PROVIDED BY AT&T. THE CONTRACTOR SHALL PROVIDE ADEQUATE PROTECTION FOR THE SAFETY OF THE OWNER'S EMPLOYEES, WORKMEN, AND ALL TIMES DURING THE CONSTRUCTION OF THE PROJECT. VICINITY MAP THE CONTRACTOR SHALL BE REQUIRED TO PAY FOR ALL NECESSARY PERMITS AND/OR FEES WITH RESPECT SHEET INDEX TO THE WORK TO COMPLETE THE PROJECT. BUILDING PERMIT APPLICATIONS SHALL BE FILED BE THE OWNER OR HIS REPRESENTATIVE. CONTRACTOR SHALL OBTAIN PERMIT AND MAKE FINAL PAYMENT FOR SAID DOCUMENT. SHEET # DESCRIPTION FINAL AT&T GC TO VERIFY ALL MEASUREMENTS OF EXISTING CONDUITS FOR FIBER RUN AND ANY POWER RUNS. T-1 TITLE SHEET D 5/1/2026 CMJ MAY ZONING DRAWINGS DO NOT SCALE DRAWINGS LS-1 SURVEY BOUNDARY 90% REVISED C 8/21/2025 CMJ MAY LS-2 SURVEY DETAIL PRELIMINARY ZD'S 90% PRELIMINARY B 7/23/2025 CMJ MAY SITE INFORMATION ZD'S A-1.0 UTILITY SITE PLAN DRIVE LEASE PROPERTY OWNER: COMMERCIAL RESOURCE A-2 NEW ENLARGED COMPOUND PLAN A 6/9/2025 CMJ MAY EXHIBIT INVESTORS III, LLC 3855 W. RAY RD, #3 A-3 ANTENNA LAYOUT & DETAILS MCCLINTOCK PROFESSIONAL SEAL CHANDLER, AZ 85226 A-3.1 EXISTING ELEVATIONS A-4 NEW ELEVATIONS N. APPLICANT: PUBLIC SAFETY TOWERS COMPANY 701 PALOMAR AIRPORT RD #160 N W. RAY ROAD CARLSBAD, CA 92011 ONLY CONTACT: SAM GUDINO PHONE: (760) 612-9949 WINDMILLS PRELIMINARY BOULEVARD EMAIL: S.GUDINO@PSTCTOWERS.COM DRAWINGS TOWER TYPE: MONOBROADLEAF SITE N. CALL 811 or (800) 782-5348 ZONING WWW.ARIZONA811.COM SITE TYPE: WIRELESS COMMUNICATIONS FACILITY CONTRACTOR TO CALL TO VERIFY APN: 301-64-876 AR ZONA UTILITIES AT LEAST TWO WORKING R BLUE INC. STAKE, DAYS PRIOR TO DIGGING FOR LATITUDE 33° 19' 09.396" N 33.319277° LONGITUDE 111° 54' 34.393" W APPLICABLE CODES RFDS DATA SUMMARY YDC PROJECT NUMBER -111.909554° EXISTING ELEVATION: ±1179.5' SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, DESIGN PACKAGE BASED ON RF DATA SHEET YDC-11352 RFDS NAME: GOODAZ-0284_RFDS_Prelim_2026-04-24.pdf STATE, AND LOCAL CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING RFDS ID: RFDS-24510 EXISTING ZONING: PAD JURISDICTION (AHJ) FOR THE LOCATION. THE EDITION OF THE AHJ ADOPTED VERSION: 1.0 CODES AND STANDARDS IN EFFECT ON THE DATE OF CONTRACT AWARD SHALL RFDS DATE: 14/03/2024 UPDATED BY ac7856 ON 24/04/2026 SHEET TITLE GOVERN THE DESIGN. CONSTRUCTION TYPE: V-B SUMMARY OF EQUIPMENT: 1. BUILDING CODE: INTERNATIONAL BUILDING CODE 2024 NUMBER OF SECTORS: . . . . . . . . . . . . . . 3 PROPOSED LEASE AREA: 756.42 SQ FT. (PSTC LEASE AREA) 2. ELECTRICAL CODE: NATIONAL ELECTRICAL CODE 2023 NUMBER OF ANTENNAS: . . . . . . . . . . . . . 9 3. LIGHTNING PROTECTION CODE: NFPA 780-2017, LIGHTNING PROTECTION NUMBER OF RRH'S: . . . . . . . . . . . . . . . 9 TITLE SHEET PROPOSED OCCUPANCY: UNMANNED TELECOMMUNICATIONS FACILITY CODE NUMBER OF FIBER OPTIC CABLES (JUMPERS) . . 1 4. EIA/TIA 222G NUMBER OF FIBER/DC SQUIDS: . . . . . . . . . 2 EXISTING OCCUPANCY: UNMANNED TELECOMMUNICATIONS FACILITY NUMBER OF FIBER TRUNK CABLES . . . . . . . 2 FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS NUMBER OF DC TRUNK CABLES . . . . . . . . . 4 JURISDICTION: CITY OF CHANDLER REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. SHEET NUMBER ELECTRICAL PROVIDER: SRP WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN. FIBER PROVIDER: COX T-1 THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. E. WARNER RD. FLOOD ZONE DESIGNATION SURVEYOR NOTES SCHEDULE B EXCEPTIONS THE PROPOSED LEASE PREMISES SHOWN HEREON APPEAR TO BE WITHIN FLOOD 1. ALL TITLE INFORMATION IS BASED UPON A COMMITMENT FOR TITLE 4.1 EASEMENT BY COMMERCIAL RESOURCE INVESTORS III, L.L.C., AN RD ZONE "X" AS DELINEATED ON THE FEDERAL EMERGENCY MANAGEMENT AGENCY INSURANCE PREPARED U.S. TITLE SOLUTIONS, ORDER NO.: UST81269 ARIZONA LIMITED LIABILITY COMPANY TO TUTOR SOUTH TEMPE GROUP, RD. FIRM MAP NO. 04013C2710L DATED 10/16/2013. EFFECTIVE DATE: 09/23/2025. LLC, AN ARIZONA LIMITED LIABILITY COMPANY, DATED APRIL 23, 2007, RURAL RECORDED APRIL 24, 2007, IN INSTRUMENT NO: 2007-0475189. FLOOD ZONE "X" IS DEFINED AS: AREAS DETERMINED TO BE OUTSIDE 500-YEAR 2. SURVEYOR HAS NOT PERFORMED A SEARCH OF PUBLIC RECORDS TO NOTES: SEWER S. E. RAY RD FLOODPLAIN; DETERMINED TO BE OUTSIDE THE 1% AND 0.2% ANNUAL CHANCE DETERMINE ANY DEFECT IN TITLE. MCCLINTOCK FLOODPLAINS. 4.2 EASEMENT BY RAY & MCCLINTOCK ASSOCIATES LIMITED PARTNERSHIP, 3. THE BOUNDARY SHOWN HEREON IS PLOTTED FROM RECORD AN ARIZONA LIMITED PARTNERSHIP TO SALT RIVER PROJECT INFORMATION AND DOES NOT CONSTITUTE A BOUNDARY SURVEY OF E. AGRICULTURAL IMPROVEMENT AND POWER DISTRICT, A THE PROPERTY. POLITICAL SUBDIVISION OF THE STATE OF ARIZONA, DATED FEBRUARY 14, 1994, RECORDED MARCH 01, 1994, IN INSTRUMENT NO: 94-0170395. PROJECT META DATA 4. SURVEYOR DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR E. CHANDLER BLVD. NOTES: UNDERGROUND ELECTRICAL 1. ELEVATIONS SHOWN HEREON ARE REPRESENTED IN NORTH THEIR LOCATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND AMERICAN VERTICAL DATUM OF 1988 (NAVD88) ESTABLISHED FROM DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED GPS DERIVED ELLIPSOID HEIGHTS, APPLYING GEOID 18B SEPARATIONS AGENCIES TO LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. 4.3 EASEMENT BY RAY & MCCLINTOCK ASSOCIATES LIMITED PARTNERSHIP, CONSTRAINING TO NGS CORS STATIONS PROVIDED IN THE "ONLINE REMOVAL, RELOCATION AND/ OR REPLACEMENT IS THE RESPONSIBILITY AN ARIZONA LIMITED PARTNERSHIP TO SALT RIVER PROJECT POSITIONING USER SERVICE" (OPUS) SOLUTION FOR THIS SPECIFIC OF THE CONTRACTOR. AGRICULTURAL IMPROVEMENT AND POWER DISTRICT, A POLITICAL SUBDIVISION OF THE STATE OF ARIZONA, ITS SUCCESSORS SITE. AND ASSIGNS, DATED JUNE 13, 1991, RECORDED JUNE 21, 1991, IN 2. BEARINGS SHOWED HEREON ARE BASED UPON U.S. STATE PLANE INSTRUMENT NO: 91-286026. NAD83 COORDINATE SYSTEM ARIZONA STATE PLANE COORDINATE NOTES: UNDERGROUND ELECTRICAL CONDUIT ZONE CENTRAL, DETERMINED BY GPS OBSERVATIONS. LESSOR'S LEGAL DESCRIPTION ITEMS 1 THRU 3, 4.4 - 4.10, 5.1 - 6.2 OF THE CLIENT PROVIDED TITLE 3. FIELD WORK FOR THIS PROJECT WAS PERFORMED ON 07/02/25. LOT 4, RAY & MCCLINTOCK PLAZA, ACCORDING TO BOOK 327 OF MAPS, PAGE 42, REPORT DO NOT CONTAIN GRAPHICALLY PLOTTABLE EASEMENTS, RECORDS OF MARICOPA COUNTY, ARIZONA. SETBACKS, RESTRICTIONS OR OTHER ENCUMBRANCES. THE SURVEYOR CANNOT GUARANTEE THAT NON-PLOTTABLE ENCUMBRANCES DO NOT EXIST THAT MAY AFFECT THE SUBJECT LEASED PREMISES. architecture / project management 10245 E. Via Linda, Scottsdale, AZ 85258 ph: 480 451 9609 fax: 480 451 9608 e mail: corp@ydcoffice.com W W W W W G W W W W W SS SS SS SS SS SS SS FND SS SS SS SS S SS SS SS SS SS SS SS S SS SS SS W BCFL WEST RAY ROAD FIELD BY: TG G SS (65' RIGHT-OF-WAY) W DRAWN BY: JMM CB FO FO FO FO FO FO FO FO FO G SS T H Y D E UGE ET T UGE UGE UGE UGE UGE PARCEL CHECKED BY: RLF LINE PARCEL S 65.00' (OTHER) LINE G (ASSESSOR) REVISIONS (OTHER) R/W 8' PUE LOT "3" G G 1 09/26/25 TITLE REVIEW LOT "1" 0 07/11/25 PRELIMINARY G LOT "5" NO. DATE DESCRIPTION G FND PK/WASH PARCEL PARCEL LINE LINE DRIVE PARCEL PARCEL LINE LINE (OTHER) (OTHER) E D L A N D RIGHT-OF-WAY) T E R T I F I C A T E S U R MCCLINTOK I S jsultzbach@com-serv.com jsultzbach@com-serv.com C E R N O . V E G 44007 Y E O FND FND PRELIMINARY R RYAN L. R PK/WASH PK/WASH D a FIDLER t e S i g n e d A R I Z O N A , U . S . A . 4.2 (55' (E) ELECTRCAL NORTH EASEMENT REUSE OF DOCUMENT LOT "4" THE IDEAS & DESIGN INCORPORATED HEREON, AS AN LOT "2" S INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RLF CONSULTING, LLC. 55.00' R/W SURVEY DETAIL (ASSESSOR) PROJECT No. SHEET LS-2 2500544 SITE NAME: GOODAZ0284 4.3 (E) ELECTRCAL EASEMENT SITE ADDRESS: PARCEL PARCEL 3875 W. RAY RD. LINE LINE (OTHER) CHANDLER, AZ 85226 NORTH 4.3 SHEET TITLE: 4.3 4.3 (E) ELECTRCAL EASEMENT SURVEY BOUNDARY (E) ELECTRCAL (E) ELECTRCAL EASEMENT EASEMENT SHEET NO. REVISION: PARCEL FND LINE LS-1 BCFL G PARCEL G LINE (E) BUILDING PARCEL G LINE (OTHER) G G 1180.9 TBC 1181.0 TBC 1180.8 TBC 1180.9 TBC 1180.1 TBC (E) GATE PARCEL 1180.4 TBC 1179.8 PV LINE PROPOSED TOWER architecture / project management CENTER OF GEODETIC COORDINATES 10245 E. Via Linda, Scottsdale, AZ 85258 LAT.= 33° 19' 09.396" NORTH 33.319277 NORTH ph: 480 451 9609 fax: 480 451 9608 LON.= 111° 54' 34.393" WEST (E) FACE e mail: corp@ydcoffice.com 111.909554 WEST OF CURB ELEV. @ GROUND =1179.5' 1179.8 TBC 1179.4 TBC FIELD BY: TG 1179.8 TBC 1179.6 TBC 1179.6 TBC DRAWN BY: JMM 1179.9 TBC CHECKED BY: RLF 1180.5 TBC REVISIONS LEGEND BRASS CAP FLUSH PK/WASHER E ELECTRICAL PULL BOX LIGHT POST S SANITARY SEWER MANHOLE 1178.2 PV DRY WELL 1 09/26/25 TITLE REVIEW 5280.00 NG SPOT ELEVATION 1178.5 PV 1179.4 PV 0 07/11/25 PRELIMINARY 1179.1 PV PROPERTY LINE 1178.3 PV PROPERTY LINE (OTHER) NO. DATE DESCRIPTION 1178.6 PV CENTERLINE (E) PARKING LOT 1180.4 TBC 1178.9 PV 1179.1 PV 1179.4 PV 1179.2 PV 1178.9 PV 1179.1 PV E D L A N D T E R T I F I C A T E S U R I S jsultzbach@com-serv.com jsultzbach@com-serv.com C E R N O . V E G 44007 Y E O PRELIMINARY R RYAN L. R D FIDLER a t e S i g n e d A R I Z O N A , U . S . A . PARCEL LINE REUSE OF DOCUMENT 1179.9 TBC NORTH THE IDEAS & DESIGN INCORPORATED HEREON, AS AN 1179.8 TBC 1179.9 TBC INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF RLF CONSULTING, LLC & IS NOT TO BE USED FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION OF RLF CONSULTING, LLC. 1179.8 TBC PROJECT No. 1179.9 TBC 1179.9 TBC 1180.0 TBC 2500544 4.1 (E) 15' SEWER EASEMENT SITE NAME: GOODAZ0284 1180.2 PV 1180.3 PV S 1180.1 PV 1180.4 PV SITE ADDRESS: 3875 W. RAY RD. CHANDLER, AZ 85226 1180.8 TBC (E) BACK 1180.9 TBC OF CURB SHEET TITLE: SURVEY DETAIL (E) BUILDING SHEET NO. REVISION: LS-2 SETBACK FROM CENTERLINE OF MONOBROADLEAF TOWER TO NEAREST PROPERTY LINE AT&T NORTHERLY: 32'-8" SOUTHERLY: 357'-4" RAY ROAD N88° 48' 28"E 1355 W. UNIVERSITY DRIVE 655.46' EASTERLY: 379'-9" MESA, AZ 85201 R.O.W. 40'-8" WESTERLY: EXISTING SRP ASSESSOR TRANSFORMER EXISTING COX PEDESTAL 65'-0" #P0402 426683 (POTENTIAL FIBER P.O.C.) POWER P.O.C. PROPERTY LINE 701 PALOMAR AIRPORT RD #160 CARLSBAD, CA 92011 ADJACENT PROPOSED PSTC 12' (P) U.G. ELEC. CONDUIT & PROPERTY LINE WIDE ACCESS / CONDUCTORS FROM (E) UTILITY EASEMENT POWER SOURCE TO (N) TRANSFORMER, ±659'-2" (P) U.G. FIBER CONDUIT FROM FIBER SOURCE TO LOT 3 LOT 5 PROPOSED AT&T 3-BAY PROPOSED AT&T ANTENNA ARRAY ZONING: PAD ZONING: PAD WUC CABINET, ±632'-0" ON PROPOSED PSTC 65' MONOBROADLEAF, (70' O.H.) INSIDE EXISTING PROVIDE A TRAFFIC-RATED YOUNG DESIGN CORP. DOES NOT GUARANTEE THAT ALL UTILITIES ARE SHOWN OR PSTC COMPOUND, SEE A-3 SHEET THEIR LOCATIONS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND BUILDING JUNCTION BOX FOR POWER DEVELOPER TO CONTACT BLUE STAKE AND ANY OTHER INVOLVED AGENCIES TO FOR CONFIGURATION 32'-8" SETBACK LOCATE ALL UTILITIES PRIOR TO CONSTRUCTION. REMOVAL, RELOCATION AND/OR FND PK / WASH REPLACEMENT IS THE RESPONSIBILITY OF THE CONTRACTOR. EXISTING PARKING LOT LIGHT PROVIDE A TRAFFIC-RATED EXISTING POLE, TO BE REMOVED, LED LIGHT BUILDING JUNCTION BOX FOR FIBER TO BE RELOCATED TO S88° 48' 28"W PROJECT: NEW BUILD LEGEND MONOBROADLEAF TRUNK AT 212.70' PTSC SITE NO.: GOODAZ-0284 ABBREVIATIONS: SYMBOLS: EXISTING HEIGHT SITE NAME: MCCLINTOCK (E) - EXISTING (N) - NEW FIRE HYDRANT SETBACK AT&T SITE ID / FA: AZL01562 / 15458390 379'-9" (F) - FUTURE POWER POLE 40'-8" SPD BOX DC FIBER VERTIV USID: 503892 ELECTRIC MANHOLE EXISTING SETBACK LBS PTLC 150 ADDRESS: 3875 W. RAY ROAD PUE PUBLIC UTILITY EASEMENT 1 TELCO MANHOLE CHANDLER, AZ 85226 ROW RIGHT OF WAY BUILDING A-2 FND PK / WASH COUNTY: MARICOPA COUNTY PROPOSED PSTC 9' CMU FND PK / WASH BLUE STAKE ELECTRIC PROPERTY LINE BLUE STAKE TELCO WALLED EQUIPMENT EXISTING CONTOUR LINE BLUE STAKE GAS BLUE STAKE WATER COMPOUND SURROUNDING PARKING LOT PROPOSED AT&T EQUIPMENT EXISTING & MONOBROADLEAF TOWER APN: 301-64-876 PARKING LOT ZONE: PAD OWNER: COMMERCIAL RESOURCE INVESTORS III, LLC SIGNS FINAL D 5/1/2026 CMJ MAY ZONING DRAWINGS 1. INSTALL ADDRESS PLACARD NEAR ENTRANCE GATE OF EQUIPMENT AREA LOT 2 LOT 4 (OR FACING STREET OF ASSOCIATED ADDRESS). 90% REVISED ZONING: PAD ZONING: PAD C 8/21/2025 CMJ MAY PRELIMINARY ZD'S LIGHTING 90% PRELIMINARY B 7/23/2025 CMJ MAY 1. ADDITIONAL LIGHTING WILL BE INSTALLED IF REQUIRED BY MUNICIPALITY ZD'S SETBACK FOR SECURITY PURPOSES. LEASE A 6/9/2025 CMJ MAY 2. ALL LIGHTING IS TO BE INSTALLED NO HIGHER THAN 8'-0", (UNLESS EXHIBIT REQUIRED OTHERWISE BY INDIVIDUAL MUNICIPALITY). 357'-4" PROFESSIONAL SEAL 3. ALL LIGHTING WILL BE THAT OF "FULL CUT OFF LENSES". COMPLIANCE 1. ADA COMPLIANCE: FACILITY IS NOT STAFFED AND NOT NORMALLY ONLY OCCUPIED. PRELIMINARY 2. CONTRACTOR IS RESPONSIBLE FOR ERECTING TEMPORARY BARRICADES DRAWINGS AND/OR FENCING TO PROTECT THE SAFETY OF THE PUBLIC DURING CONSTRUCTION. EXISTING EXISTING 21'-0" ZONING BUILDING HIGH BUILDING 3. THE ANTENNAS SHALL NOT INTERFERE WITH ANY EXISTING COMMUNICATION SITES. 4. DEVELOPMENT AND USE OF THIS SITE WILL CONFORM TO ALL APPLICABLE FOR CODES AND ORDINANCES. 5. ALL ITEMS ON THIS DRAWING ARE EXISTING UNLESS OTHERWISE NOTED. YDC PROJECT NUMBER NOTES 1. SITE PLAN RENDERING DERIVED FROM DETAILS PROVIDED FROM YDC-11352 ASSESSORS MAP & SITE AUDIT. 2. REFER TO AT&T SPECIFICATIONS FOR ADDITIONAL CARRIER SHEET TITLE INFORMATION/DETAILS. 3. G.C. TO VERIFY EXISTING FIELD CONDITIONS AND DIMENSIONS PRIOR TO N CONSTRUCTION UTILITY SITE PLAN 4. G.C. TO BRING ALL EXISTING AND NEW EQUIPMENT INTO COMPLIANCE WITH GOVERNING CODES. 5. G.C. TO RE-COLORCODE ALL EXISTING AND NEW AT&T COAX TO CURRENT AT&T STANDARDS. SHEET NUMBER A-1.0 GENERAL SITE NOTES N.T.S. 2 OVERALL SITE PLAN 22"x34" SCALE: 1" = 20'-0" 1 11"x17" SCALE: 1" = 40'-0" 20' 10' 0" 20' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. AT&T 1355 W. UNIVERSITY DRIVE EXISTING TRASH MESA, AZ 85201 ENCLOSURE BY OTHERS, TO REMAIN UNCHANGED PROPERTY LINE PROPOSED PSTC 12' WIDE ACCESS / UTILITY EASEMENT PROVIDE A 4AB APPROVED FIRE EXTINGUISHER ON 701 PALOMAR AIRPORT RD #160 INSIDE OF COMPOUND (P) U.G. ELEC. CONDUIT & CONDUCTORS FROM (E) POWER SOURCE TO (N) TRANSFORMER, ±659'-2" CARLSBAD, CA 92011 APPROXIMATE LOCATION OF EXISTING PARKING LOT LIGHT POLE, TO BE REMOVED, LUMINAIRE / FIXTURE TO BE RELOCATED TO PROPOSED MONOBROADLEAF TRUNK AT EXISTING HEIGHT PROPOSED PSTC 120/240V 1Ø 3-WIRE, 4-CLIP 200AMP METER & DISCONENCT ON WALL-MOUNTED UNISTRUT TO BE UTILIZED BY AT&T FOR POWER 31'-10" PROPOSED PSTC LEASE AREA / ACCESS & UTILITY EASEMENT (P) U.G. FIBER CONDUIT FROM FIBER SOURCE TO PROPOSED PSTC 9' HIGH CMU SCREEN WALL, PROPOSED AT&T 3-BAY WUC CABINET, ±632'-0" COLOR / TEXTURE TO MATCH EXISTING BUILDING TO SOUTH, W/ PAINTED STUCCO ON TOP, BOTTOM TO BE DECORATIVE ROCK (P) U.G. ELEC. CONDUIT & 5'-0" 7'-4" 5'-4" 10'-0" CONDUCTORS FROM (P) AT&T METER TO EQUIP. LOCATION, ±12'-1" PROPOSED PSTC T.S. ACCESS GATE W/ PAINTED SOLID METAL BACKING, PROPOSED AT&T SPD DC50 COLOR TO MATCH WALL MOUNTED TO SIDE OF WUC, SEE DETAIL 2 ON SHEET D-8 FOR MORE DETAILS PROJECT: NEW BUILD PTSC SITE NO.: GOODAZ-0284 SITE NAME: MCCLINTOCK PROPOSED PSTC U.G. 3"Ø CONDUIT FOR POWER AREA AT&T SITE ID / FA: AZL01562 / 15458390 BETWEEN NEW PAD USID: 503892 MOUNTED TRANSFORMER & LEASE ADDRESS: 3875 W. RAY ROAD 200AMP METER / DISCONNECT 5'-0" 4'-1" PSTC CHANDLER, AZ 85226 WALL PSTC COUNTY: MARICOPA COUNTY 5'-3" BOX FIBER SPD DC VERTIV 1'-4" PROPOSED SCREEN PROPOSED PROPOSED NEQ.20574 POLAR 3'-9" POWER, INC. 8220-100-D-20-03-V,,,,48 CMU VDC; 20KW; DC GENERATOR; 10'-8" HORIZONTAL ENCLOSURE W/ 54 13'-1" SLAB GALLON FUEL TANK WITH OPV ON PROPOSED CONCRETE SLAB, SEE 9'-0" PROPOSED AT&T ANTENNA ARRAY DETAIL 2 ON SHEET D-3 SLAB MOUNTED TO APPROVED MOUNTS AREA ON PROPOSED PSTC 65' (70' O.H.) 6'-0" 14'-0" MONOBROADLEAF TREE, SEE A-3 SHEET FOR CONFIGURATION LEASE FINAL EXISTING MEDIAN TO BE PROPOSED AT&T [CEQ.54298] VERTIV, D 5/1/2026 CMJ MAY REMOVED AND REPLACED WITH LBS PTLC 150 F2020030,,,, VERTIV WUC 3-BAY ZONING DRAWINGS PSTC PROPOSED COMPOUND CABINET W/ 6KW HEX 512DC PLANT, 90% REVISED SURROUNDED BY A CONCRETE DC HEATERS, (ALL OCCURRENCES), C 8/21/2025 CMJ MAY CURB / LANDSCAPE / 3'-10" 4'-0" 3'-10" 4'-0" MOUNTED TO CONCRETE SLAB, SEE PRELIMINARY ZD'S PROPOSED HARDSCAPE MEDIAN DETAIL 1 ON SHEET D-3 SLAB SLAB 90% PRELIMINARY 2'-6" 3'-8" WALL B 7/23/2025 CMJ MAY ZD'S SCREEN PROPOSED PARKING BUFFER MIN. 34'-7" LEASE LANDSCAPE MEDIAN, BOULDERS CMU A 6/9/2025 CMJ MAY AND LANDLORD APPROVED PSTC EXHIBIT VEGETATION TO SOFTEN & PROTECT COMPOUND PROPOSED PROFESSIONAL SEAL 14'-9" PROPOSED PSTC T.S. ACCESS GATE W/ PAINTED SOLID METAL 4'-8" 5'-4" 5'-5" APN: 301-64-876 BACKING, COLOR TO MATCH ZONING: PAD ONLY ADJACENT WALLS OWNER: COMMERCIAL RESOURCE PRELIMINARY (N) PAD MOUNTED 15'-5" PROPOSED PSTC AREA INVESTORS III, LLC DRAWINGS TRANSFORMER ON CMU SCREEN WALL LEASE CONCRETE PAD ZONING PROPOSED AT&T PTLC PSTC AC PANEL W/ CAMLOK MOUNTED TO WUC PROPOSED PROPOSED AT&T GPS 38'-2" FOR ANTENNA MOUNTED TO PIPE MOUNT ON WUC, SEE DETAIL 1 ON SHEET D-8 PROPERTY LINE ZONING: EXISTING EXISTING YDC PROJECT NUMBER PAD MEDIAN PARKING LOT YDC-11352 SHEET TITLE N ENLARGED COMPOUND SITE PLAN SHEET NUMBER A-2 ENLARGED COMPOUND SITE PLAN 22"x34" SCALE: 1/4" = 1'-0" 1 11"x17" SCALE: 1/8" = 1'-0" 4' 3' 2' 1' 0" 4' THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. NOTES: 1. NO CHAIN MOUNTS OR AT&T A SUPPORT ARE ALLOWED/ PERMITTED ON AT&T TOWER. 0° SECTOR 2. MONOBROADLEAF BRANCHES 1355 W. UNIVERSITY DRIVE AND LEAVES ARE NOT SHOWN MESA, AZ 85201 FOR CLARITY NEW RAYCAP DC9-48-60-0-24-8C-EV 9'-0" FACE WIDTH TYP. DC/FIBER SURGE PROTECTOR, SEE DETAIL 3 ON SHEET D-8, (2) TOTAL, 4'-0" TYP. 4'-0" TYP. (1) PER ALPHA & BETA SECTORS 2'-6" 2'-6" 1 TYP. 2 TYP. 3 NEW 65' PSTC MONOBROADLEAF TOWER W/ AT&T ANTENNAS (70' OVERALL HEIGHT), BRANCHES AND MIN. 1'-0" LEAVES NOT SHOWN FOR CLARITY NEW RRH'S, (3) PER SECTOR, 5'-0" MIN) ERICSSON 4490 B5/B12A @ POS 1 (2'-0" 3'-10" ERICSSON 4890 B25/B66 @ POS 3 ERICSSON 4494 B14/B29 @ POS 3 701 PALOMAR AIRPORT RD #160 MOUNTED TO BACK TO BACK MOUNTS CARLSBAD, CA 92011 ON V-FRAME PIPES, TYP. OF (9) RRH'S 3 1 NEW AT&T ANTENNA, COMMSCOPE NNHH-65C-R4, @ POS 1, (1) PER SECTOR, TYP. OF (3) ANTENNAS C SECTOR 240° NEW AT&T ANTENNA, ERICSSON AIR 2 2 6472 B77G / B77M, @ POS 2, (1) PER SECTOR, TYP. OF (3) ANTENNAS SECTOR NEW AT&T APPROVED MOUNTING B 120° STRUCTURE, (SITEPRO 1 T3D8-3-A3 OR 1 3 APPROVED EQUIVALENT) PROJECT: NEW BUILD PTSC SITE NO.: GOODAZ-0284 SITE NAME: MCCLINTOCK NEW AT&T ANTENNA, COMMSCOPE AT&T SITE ID / FA: AZL01562 / 15458390 NNH4-65C-R6-V4, @ POS 3, (1) PER USID: 503892 SECTOR, TYP. OF (3) ANTENNAS ADDRESS: 3875 W. RAY ROAD CHANDLER, AZ 85226 N COUNTY: MARICOPA COUNTY ANTENNA DETAILS N.T.S. 4 ANTENNA LAYOUT N.T.S. 2 NEW ANTENNA CONFIGURATION TABLE FINAL D 5/1/2026 CMJ MAY POSITION ZONING DRAWINGS COMMSCOPE RR-B2B-AR (# OR N/A) 1 2 - 3 90% REVISED TOTAL WEIGHT (UNFINISHED) 36 LBS (16.329 Kg) (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE C 8/21/2025 CMJ MAY ANTENNA PRELIMINARY ZD'S NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3 ROUND LEGS 2-3/8" DIA TO 3-1/2" DIA 99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8") 90% PRELIMINARY B 7/23/2025 CMJ MAY FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER ZD'S ALL HARDWARE TO BE AZIMUTH 0° 0° 0° A LEASE TORQUED TO 35 FT-LBS (4) DC TRUNKS A 6/9/2025 CMJ MAY RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0" EXHIBIT SECTOR (2) FIBER TRUNK TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE PROFESSIONAL SEAL TMA - - - ERICSSON 4478 B12A ERICSSON 4890 B25/B66 ERICSSON 4494 B14/B29 RRH ANTENNA (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3 99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8") FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER AZIMUTH 120° 120° 120° B (4) DC TRUNKS RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0" SECTOR (2) FIBER TRUNK TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE TMA - - - - ERICSSON 4478 B12A ERICSSON 4890 B25/B66 ERICSSON 4494 B14/B29 RRH YDC PROJECT NUMBER RRH ORDERED ANTENNA (N) COMMSCOPE (N) ERICSSON (N) COMMSCOPE NNHH-65C-R4 AIR 6472 B77G / B77M NNH4-65C-R6-V3 YDC-11352 SEPARATELY 99.2lbs (96"x19.61"x7.8") 92.6lbs (36.3"x15.8"x7.4") 91.7lbs (96"x19.6"x7.8") FEEDER LENGTH ±61FT FIBER ±63FT FIBER ±61FT FIBER C AZIMUTH 240° 240° 240° SHEET TITLE (4) DC TRUNKS RAD CENTER 61'-0" 63'-0" (PWRT-606-S) 61'-0" RR-B2B-AR SECTOR (2) FIBER TRUNK ANTENNA LAYOUT & MOUNT TECHNOLOGY LTE, 5G 5G (RFFT-36SM-001-30M) LTE TMA - - - DETAILS RRH BACK TO ERICSSON 4478 B12A ERICSSON 4890 B25/B66 MOUNTING PIPE BACK MOUNT RRH ERICSSON 4494 B14/B29 SHEET NUMBER BACK TO BACK ANGLE MOUNT A-3 BACK TO BACK MOUNT DETAIL N.T.S. 3 ANTENNA CONFIGURATION TABLE N.T.S. 1 THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. NOTE: NO CHAIN MOUNTS OR SUPPORT ARE AT&T ALLOWED/ PERMITTED ON AT&T TOWER. 1355 W. UNIVERSITY DRIVE MESA, AZ 85201 701 PALOMAR AIRPORT RD #160 CARLSBAD, CA 92011 PROJECT: NEW BUILD PTSC SITE NO.: GOODAZ-0284 SITE NAME: MCCLINTOCK AT&T SITE ID / FA: AZL01562 / 15458390 USID: 503892 ADDRESS: 3875 W. RAY ROAD CHANDLER, AZ 85226 COUNTY: MARICOPA COUNTY FINAL D 5/1/2026 CMJ MAY ZONING DRAWINGS 90% REVISED C 8/21/2025 CMJ MAY PRELIMINARY ZD'S 90% PRELIMINARY B 7/23/2025 CMJ MAY ZD'S EXISTING LED LUMINAIRE, SHALL BE EXISTING LED LUMINAIRE, SHALL BE SALVAGED IF POSSIBLE, OTHERWISE A SALVAGED IF POSSIBLE, OTHERWISE A LEASE REPLACEMENT LUMINAIRE W/ SAME REPLACEMENT LUMINAIRE W/ SAME A 6/9/2025 CMJ MAY EXHIBIT OUTPUT TO BE INSTALLED ON OUTPUT TO BE INSTALLED ON BROADLEAF TOWER AT EXISTING HEIGHT BROADLEAF TOWER AT EXISTING HEIGHT PROFESSIONAL SEAL LOT LOT PARKING PARKING REMOVED REMOVED ONLY PRELIMINARY EXISTING BE EXISTING BE DRAWINGS TO TO ZONING OF POLE OF POLE TOP TOP LIGHT LIGHT EXISTING PARKING TO EXISTING PARKING TO FOR LOT LIGHT POLE & LOT LIGHT POLE & FOUNDATION, TO BE 30'-0" FOUNDATION, TO BE 30'-0" REMOVED REMOVED EXISTING TRASH ENCLOSURE, TO YDC PROJECT NUMBER REMAIN UNCHANGED EXISTING EXISTING YDC-11352 CONCRETE CURB / CONCRETE CURB / PARKING MEDIAN, PARKING MEDIAN, TO BE REMOVED TO BE REMOVED SHEET TITLE EXISTING ELEVATIONS SHEET NUMBER A-3.1 22"x34" SCALE: 3/16" = 1'-0" 22"x34" SCALE: 3/16" = 1'-0" EXISTING SOUTH ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 2 EXISTING WEST ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 1 THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED. NOTE: NO CHAIN MOUNTS OR SUPPORT ARE AT&T ALLOWED/ PERMITTED ON AT&T TOWER. 1355 W. UNIVERSITY DRIVE MESA, AZ 85201 701 PALOMAR AIRPORT RD #160 CARLSBAD, CA 92011 PROPOSED AT&T ANTENNA ARRAY MOUNTED TO APPROVED MOUNTS ON PROPOSED AT&T ANTENNA ARRAY PROPOSED AT&T 65' MONOBROADLEAF MOUNTED TO APPROVED MOUNTS ON TOWER (70' OVERALL HEIGHT), SEE A-3 PROPOSED AT&T 65' MONOBROADLEAF SHEET FOR CONFIGURATION TOWER (70' OVERALL HEIGHT), SEE A-3 SHEET FOR CONFIGURATION 8'-0" 8'-0" PROPOSED AT&T ANTENNA PROJECT: NEW BUILD SOCKS TO CONCEAL PROPOSED AT&T ANTENNA ANTENNAS FROM VIEW WITHIN PTSC SITE NO.: GOODAZ-0284 SOCKS TO CONCEAL MONO-BROADLEAF TOWER SITE NAME: MCCLINTOCK ANTENNAS FROM VIEW WITHIN MONO-BROADLEAF TOWER AT&T SITE ID / FA: AZL01562 / 15458390 USID: 503892 ADDRESS: 3875 W. RAY ROAD HEIGHT) HEIGHT) CHANDLER, AZ 85226 COUNTY: MARICOPA COUNTY PROPOSED AT&T (4) POWER TRUNKS, (2) FIBER TRUNKS, ROUTED (OVERALL (OVERALL UP MONO-BROADLEAF TOWER TOWER TOWER PROPOSED AT&T (4) POWER TRUNKS, (2) FIBER TRUNKS, ROUTED UP BRANCHES ARRAY BRANCHES ARRAY MONO-BROADLEAF TOWER ARRAY ARRAY ARRAY ARRAY MONO-BROADLEAF MONO-BROADLEAF ANTENNA ANTENNA ANTENNA ANTENNA ANTENNA ANTENNA PROPOSED RELOCATED / MONO-BROADLEAF MONO-BROADLEAF REPLACEMENT PARKING LOT LED AT&T AT&T AT&T PROPOSED RELOCATED / AT&T AT&T AT&T FINAL LIGHT MOUNTED AT EXISTING AT&T AT&T D 5/1/2026 CMJ MAY OF REPLACEMENT PARKING LOT OF ZONING DRAWINGS HEIGHT (ON OPPOSITE SIDE), OF LED LIGHT MOUNTED AT OF VERIFY HEIGHT IN FIELD OF OF 90% REVISED EXISTING HEIGHT, VERIFY CENTER TIPS PROPOSED CENTER TIPS PROPOSED AT&T C 8/21/2025 CMJ MAY AT&T HEIGHT IN FIELD PRELIMINARY ZD'S CENTER CENTER 90% PRELIMINARY RAD PROPOSED OF RAD PROPOSED OF B 7/23/2025 CMJ MAY PROPOSED RAD PROPOSED RAD PROPOSED ZD'S MONOBROADLEAF FAUX STEEL STEEL LEASE BARK CLADDING UP TO PROPOSED TO PROPOSED TO A 6/9/2025 CMJ MAY BOTTOM BRANCHES PROPOSED OF OF PROPOSED OF OF EXHIBIT 65'-0" PROPOSED NEQ.20574 POLAR POWER, 65'-0" PROPOSED NEQ.20574 POLAR POWER, TOP TOP INC. 8220-100-D-20-03-V,,,,48 VDC; TOP TOP PROFESSIONAL SEAL TO TO INC. 8220-100-D-20-03-V,,,,48 VDC; LUMINAIRE TO 20KW; DC GENERATOR; HORIZONTAL LUMINAIRE TO TO TO TO TO 20KW; DC GENERATOR; HORIZONTAL 63'-0" ENCLOSURE W/ 54 GALLON FUEL TANK 63'-0" ENCLOSURE W/ 54 GALLON FUEL TANK 61'-0" 65'-0" 70'-0" WITH OPV ON PROPOSED CONCRETE 61'-0" 65'-0" 70'-0" WITH OPV ON PROPOSED CONCRETE SLAB, SEE DETAIL 2 ON SHEET D-3 SLAB, SEE DETAIL 2 ON SHEET D-3 REPLACEMENT PROPOSED TRANSFORMER REPLACEMENT ONLY PROPOSED PSTC T.S. ACCESS GATE PROPOSED AT&T DC50 SPD W/ PAINTED SOLID METAL BACKING, CABINET MOUNTED TO SIDE INSTALLED ON PROPOSED PRELIMINARY COLOR TO MATCH ADJACENT WALLS OF 3-BAY WUC (BEYOND) CONCRETE PAD NEAR GATE / / DRAWINGS PROPOSED PSTC 9' HIGH DECORATIVE PROPOSED PSTC 9' HIGH ZONING PROPOSED CMU WALLED COMPOUND W/ 2' OF BRANCHES RELOCATED DECORATIVE CMU WALLED BRANCHES RELOCATED PROPOSED GPS ANTENNA ROCK AT BASE TO MATCH PILLARS ON COMPOUND W/ 2' OF ROCK AT GPS ANTENNA MOUNTED TO BUILDING TO SOUTH, FOR FULL BASE TO MATCH PILLARS ON MOUNTED TO PIPE ON WUC SCREENING OF EQUIPMENT BUILDING TO SOUTH, FOR FULL PIPE ON WUC OF SCREENING OF EQUIPMENT OF FOR BOTTOM BOTTOM TOP TOP EXISTING TRASH PROPOSED 200AMP AT&T PROPOSED TRANSFORMER TO TO ENCLOSURE, TO METER / DISCONNECT ON TO TO INSTALLED ON PROPOSED WALL REMAIN UNCHANGED WALL-MOUNTED UNISTRUT CONCRETE PAD NEAR GATE 20'-0" 30'-0" 20'-0" 30'-0" YDC PROJECT NUMBER CMU 9'-0" YDC-11352 9'-0" PROPOSED CONCRETE MEDIAN SURROUNDING PROPOSED PSTC EQUIPMENT COMPOUND SHEET TITLE PROPOSED AT&T [CEQ.54298] VERTIV, PROPOSED AT&T F2020030,,,, VERTIV WUC 3-BAY CABINET W/ PTLC AC PANEL W/ 6KW HEX 512DC PLANT, DC HEATERS, (ALL CAMLOK MOUNTED ELEVATIONS OCCURRENCES), MOUNTED TO CONCRETE TO SIDE OF WUC SLAB, SEE DETAIL 1 ON SHEET D-3 PROPOSED CONCRETE MEDIAN SURROUNDING PROPOSED PSTC EQUIPMENT COMPOUND SHEET NUMBER A-4 22"x34" SCALE: 3/16" = 1'-0" 22"x34" SCALE: 3/16" = 1'-0" NEW SOUTH ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 2 NEW WEST ELEVATION 11"x17" SCALE: 3/32" = 1'-0" 4' 2' 0" 4' 1 THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS PROPRIETARY AND CONFIDENTIAL TO AT&T WIRELESS. ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T WIRELESS IS STRICTLY PROHIBITED.