AQ-2017-007-R323-324-REPORTTOTHEBOARDOFSUPERVISORS-2021-06-23.PDF
Extracted text (via pymupdf_layout)
399842 characters
Executive Summary of the Report to the Board of Supervisors Prepared by the Maricopa County Air Quality Department Board Hearing Date: June 23, 2021 Case Number/Title: AQ-2017-007: Rule 323 (Fuel Burning Equipment from Industrial/Commercial/Institutional (ICI) Sources) Rule 324 (Stationary Reciprocating Internal CombustionEngines (RICE)) Agenda Item: (Pending) Supervisor Districts: All Districts The Maricopa County Air Quality Department (MCAQD) complied with all statutory and county policies throughout this rulemaking process. Per the Enhanced Regulatory Outreach Program (EROP) Policy: “In addition to the required staff report, an executive summary of the report including an overview of stakeholder input and staff responses will be provided to the Board of Supervisors at least one week prior to any Board of Supervisors’ public hearing.” Overview of the Report to the Board of Supervisors: On May 4, 2016, portions of Maricopa County were designated as a moderate nonattainment area with respect to the 2008 National Ambient Air Quality Standards for Ozone. Sections 182(b)(2) and 182(f) of the Clean Air Act require jurisdictions that are classified as “moderate” or higher nonattainment to implement reasonably available control technology (RACT) for all categories of volatile organic compound (VOC) sources covered by a Control Technique Guideline document as well as for all major stationary sources of NOX and VOCs that are located within the nonattainment area. The U.S. Environmental Protection Agency (EPA) defines RACT as “the lowest emission limitation that a particular source is capable of meeting by the application of control technology that is reasonably available considering technological and economic feasibility.” The EPA provides guidance on RACT for sources of NOX through Alternative Control Technology documents which offer State and local air pollution control authorities information that assists in determining NOX-RACT for air quality rules. In addition, the EPA reviews state implementation plan (SIP)-approved air quality rules from other air districts with ozone nonattainment areas to assist in determining NOX-RACT for air quality rules. In November 2016, Rules 323 and 324 were revised to implement RACT for sources of NOX. The revised rules were submitted to the EPA in June of 2017, as part of the SIP Revision for the Maricopa County Air Quality Department Ozone Rules contained in the Arizona SIP. The EPA reviewed Rules 323 and 324, and provided the MCAQD with written rule approvability and rule improvement comments for the rules. EPA staff informed MCAQD staff they would be using a conditional approval process to act on Rules 323 and 324, and the MCAQD would need to draft a commitment letter outlining revisions to Rules 323 and 324 to address the rule approvability comments. On January 28, 2019, the MCAQD submitted a Letter of Commitment for Conditional Approval of the Maricopa County RACT SIP to the EPA. Later, on December 5, 2019, the MCAQD submitted a supplemental commitment letter for Rule 324 to address additional rule approvability comments MCAQD received after the original commitment letter was submitted. Based on the commitment letters, the EPA published a proposed conditional approval of Rules 323 and 324 in the Federal Register on December 30, 2019 (Docket ID; EPA-R09-OAR-2019-0321). The proposed conditional approval rulemaking was available 1 for a 30-day comment period, but no comments were received. The proposed conditional approval outlined EPA’s official rule approvability comments (“rule deficiencies”) which precluded full approval of the rules into the Arizona SIP. EPA’s final conditional approval was published on July 20, 2020. The effective date of the final rule was August 19, 2020. If the MCAQD, through the ADEQ, submits the rule revisions that the MCAQD has committed to submit within 12 months and the EPA approves the submission, then the identified deficiencies will be cured, and the rules will be approved as part of the Arizona SIP. Revisions addressing the EPA’s identified deficiencies have been made to Rules 323 and 324 and are included in this report. Overview of Stakeholder Input and Staff Responses: During the rulemaking process, the MCAQD received written comments from four (4) stakeholders. The stakeholders expressed neither support nor opposition for the rulemaking. The MCAQD evaluated the comments and drafted responses. The stakeholder comments and the MCAQD responses to the comments are listed below. The following comments and responses are applicable to Rule 323: Comment #1: This rule contains similar requirements for tracking fuel use and days/hours of operation. I would like to request the same change as stated above (for R322, section 501.1 - This rule now requires records of the type and amount of fuel used, sulfur content and days and hours of operation. I would like to remove the requirement to track days and hours of operation and that fuel use be required to be tracked monthly. Fuel tracking monthly makes the most sense since invoices are typically sent monthly (in the case of natural gas). I have been unable to identify a reason to track days and hours of operation. This information does not appear to be needed to determine compliance). Response #1: The MCAQD considered your comment and deleted the requirement for days and hours of operation. In addition, the MCAQD clarified that fuel usage be tracked monthly. Comment #2: In Maricopa County’s (the County) workshop presentation, the County recommends accepting the more stringent boiler tuning requirements and suggests requirements based rated capacity and whether or not the source was at a major source. Concerning the County’s recommendations for altering requirements based on rated capacity of the unit, [our Company] suggests an alternative. [Our Company] has reviewed EPA’s comment and believe EPA was intending to apply RACT to “major source units” (units emitting 100 tons/yr of NOx) and not a minor source unit at a “major source” as suggested by the County’s proposed commitment. [Our Company] requests that RACT requirements only apply to major source units. Applying a major source applicability limit would be consistent with EPA’s recommendation with Rule 322. [Our Company] owns a Clayton Boiler rated at 11 MBtu/hr, which emits approximately 25 lbs per year. [Our Company] has reviewed the examples for boiler tuning requirements and find them excessive in some situations for simple and small units. Multiple items in the referenced boiler tuning requirements could not work for this unit. [Our Company] doesn't support more stringent requirements for the smaller units. At a minimum, there should be language that accommodate the size and design of the unit. Response #2: The MCAQD considered your comment and developed a table that clearly outlines which combustion units at a major source of NOx must comply with RACT requirements, see Table 323-1 in the draft rule. Some smaller combustion units, units greater than 10 MMBtu/hour and less than or equal to 50 MMBtu/hour with annual heat input less than 220,000 therms, will not have to comply with RACT requirements. The following comments and responses are applicable to Rule 324: Comment #1: The hours of operation for emergencies should be specified in this section and testing, reliability and maintenance hours should be grouped together as non-emergency hours. Suggested language 2 is: “Monthly and rolling twelve-month total hours of operation, emergency hours of operation, and non- emergency hours of operation (including hours for testing, reliability, and maintenance).” Response #1: The MCAQD considered your comment and revised the language in Section 502.2 to read as follows: Operation Records: An owner or operator of a stationary RICE shall maintain records of the monthly and 12-month rolling total hours of operation for each stationary RICE. For emergency engines, the operation records shall also include: a. Monthly and annual hours of operation for reliability related activities such as engine readiness, calibration, or maintenance, or to prevent the occurrence of an unsafe condition during electrical system maintenance; and b. The number of operating hours for emergency use and an explanation for the emergency use. Comment #2: We recently had several air permit inspections for our general permits that are for our emergency generators. We have been having these inspections every other year for our facilities and not had any major issues during the inspections. Each generator has a logbook that has a monthly record for the checks that take place, any operation or other issues that occur. Historically, these records were used to calculate the 12-month hours of operation to show compliance with permit conditions. However, during our recent inspections, we were informed that we had not been keeping a monthly rolling record of hours and that we needed to begin this for our general permitted sites. I've reviewed the permit and Rule 324 and understand that this is required but seems like an unnecessary effort if we keep a monthly log of hours. The previous 12 months can easily be calculated by taking March 2019 hours and subtracting March 2018 hours to show the current 12 months of hours of operation. [Our Company] emergency generators typically run less than a couple hours a month, often times even less than a couple hours. [Our Company] understands the permit language and will do what is needed to maintain compliance. However, since our sites have been inspected frequently and this has not previously been noted nor has it been noted as a compliance issue. [Our Company] believes that for remote sites that also run very limited hours that the information needed to determine hours of operation can be calculated from the on-site logbooks during inspections. Our emergency generators are typically at unmanned facilities, have limited use and would require additional effort and resources to collect and track this information. We hope to see this requirement addressed through logbook information that is maintained at each site and not a requirement to create spreadsheets for each generator (we have over 30 permitted sites). Since Rule 324 is currently being reviewed and possibly amended we hope that this issue can be addressed during this process. We would like to see this section clarified that for limited use, unmanned sites that the on-site logbook can be used to determine the 12- month hours of operation. Response #2: The MCAQD considered your comment and determined that records of the 12-month rolling total hours of operation are needed to ensure compliance with emission and/or operation limits. The information can be recorded in the logbook or using any other method as long as the required records are maintained. Comment #3: We have reviewed the language and our operations across our fleet. We are requesting the following change to the verbiage (see below). We have engines from 15 different manufactures (some are no longer in business) and only use a single qualified service provider. The use of one contractor to conduct engine is preferred by our Supply Chain because of the clearance required to work at some of our sites as well as safety hazards associated with our facilities. There are some service providers that have safety records that prohibit them from working at our sites entirely. An owner or operator of a stationary RICE shall maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the written maintenance schedule provided by the manufacturer’s authorized a qualified service provider. If the manufacturer's written instructions are not available and the manufacturer’s authorized qualified service provider does not provide a written maintenance schedule, the owner or operator shall conduct preventative maintenance according to the 3 following schedule, including all of the following procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine: Response #3: The MCAQD considered your comment and revised the language in Section 302 to read as follows: MAINTENANCE REQUIREMENTS: An owner or operator of a stationary RICE shall maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the maintenance schedule provided by the manufacturer’s authorized service provider. Alternatively, the owner or operator shall conduct preventative maintenance according to the following schedule, including all of the following tuning procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine. Comment #4: Thanks for the opportunity to provide comments in your chat room during the October 24, 2019 workshop. I notice of you could not accept a proposed comment [KB-A30] about changing the term “manufacturer’s authorized service provider” with the term “qualified service provider” because this is not a recognized term in use by the EPA. We agree with the commenters concern about the term “authorized service provider” because the term in our opinion raises proprietary issues related to maintenance documentation provided by engine and/or emergency generator manufacturers exclusively to authorized dealerships. A regular maintenance provider may have authorizations from various engine manufacturers but may not be able to get authorizations from for example emergency generator manufacturers who have their own non-road engines installed. We suggest you consider alterative options and include language in Section 302 about “or authorization from a manufacturer of a similar engine type” and “in accordance with recommendations from the manufacturer of a similar engine type.” Response #4: The MCAQD considered your comment and revised the language in Section 302 to read as follows: MAINTENANCE REQUIREMENTS: An owner or operator of a stationary RICE shall maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the maintenance schedule provided by the manufacturer’s authorized service provider. Alternatively, the owner or operator shall conduct preventative maintenance according to the following schedule, including all of the following tuning procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine. Comment #5: I have a few comments for draft Rule 324, which deals explicitly with non-road engines. I understand the purpose of tracking non-road engines and the amount of time they are onsite to ensure there is no circumvention of the rules by using a non-road engine as a stationary engine. Unfortunately, the record-keeping requirement can be quite burdensome for facilities with special events that use non-road generators for a minimal amount of time. Almost all non-road generators are brought onto the site and removed in less than a week, and many within 24 hours. Could there be a timeframe, such as seven days, that if a non-road engine is brought onsite for more than seven days, then section 502.6 applies? Additionally, the serial number requirement in Section 502.6 b. can be difficult to obtain depending on the situation. Rental companies will have the make, model, and capacity readily available for the non-road engines being rented, but not the specific serial number sent to the site. If the non-road engine is brought onto the site for a single night event, it can be challenging to obtain the serial number for an event that lasts three hours at night. Response #5: The MCAQD considered your comments and revised the language in Section 502.6 to read as follows: Nonroad Engine Records: An owner or operator of a nonroad engine shall maintain the following records for each non-road engine: a. Date that each engine is brought to the stationary source; and b. For engines located at a stationary source greater than 14 consecutive days: (1) Make, model, serial number, and rated capacity (bhp hours) of the engine; and (2) Date of each instance in which the engine is moved from its existing location, and the reason why the engine was moved; and (3) Fuel type and sulfur content of the fuel. Additionally, the MCAQD revised the applicability language in Section 102.1.d to clarify which nonroad engines are subject to the recordkeeping requirements in Rule 324. Section 102.1.d now reads as follows: Any nonroad engine, with a rated bhp of greater than 125, that is located at a stationary source that emits or has the potential to emit any regulated air pollutant greater than the permitting 4 thresholds defined in Rule 100 of these rules. For the purpose of this Rule, a nonroad engine is any internal combustion engine that by itself or in or on a piece of equipment is portable or transportable, meaning designed to be and capable of being carried or moved from one location to another. Indicia of transportability include but are not limited to, wheels, skids, carrying handles, dollies, trailers, or platforms. 5 Report to the Board of Supervisors Prepared by the Maricopa County Air Quality Department Board of Health Meeting Date: April 26, 2021 Board Hearing Date: June 23, 2021 Case Number/Title: AQ-2017-007: Rule 323 (Fuel Burning Equipment from Industrial/Commercial/Institutional (ICI) Sources) Rule 324 (Stationary Reciprocating Internal Combustion Engines (RICE)) Agenda Item: (Pending) Supervisor Districts: All Districts Applicant: Staff Request: Approve revisions to Rule 323 (Fuel Burning Equipment from Industrial/Commercial/Institutional (ICI) Sources) and Rule 324 (Stationary Reciprocating Internal Combustion Engines (RICE)) of the Maricopa County Air Pollution Control Regulations and approve submission of the revised rules as a revision to the Arizona State Implementation Plan (SIP). On May 4, 2016, portions of Maricopa County were designated as a moderate nonattainment area with respect to the 2008 National Ambient Air Quality Standards for Ozone. Sections 182(b)(2) and 182(f) of the Clean Air Act require jurisdictions that are classified as “moderate” or higher nonattainment to implement reasonably available control technology (RACT) for all categories of volatile organic compound (VOC) sources covered by a Control Technique Guideline document as well as for all major stationary sources of NOX and VOCs that are located within the nonattainment area. EPA defines RACT as “the lowest emission limitation that a particular source is capable of meeting by the application of control technology that is reasonably available considering technological and economic feasibility.” In November 2016, Rules 323 and 324 were revised to implement RACT for sources of NOX. The revised rules were submitted to the EPA in June of 2017, as part of the SIP Revision for the Maricopa County Air Quality Department (MCAQD) Ozone Rules contained in the Arizona SIP. The 6 EPA reviewed Rules 323 and 324, and provided the MCAQD with written rule approvability and rule improvement comments for the rules. EPA staff informed MCAQD staff they would be using a conditional approval process to act on Rules 323 and 324, and the MCAQD would need to draft a commitment letter outlining revisions to Rules 323 and 324 to address the rule approvability comments. On January 28, 2019, the MCAQD submitted a Letter of Commitment for Conditional Approval of the Maricopa County RACT SIP to the EPA. Later, on December 5, 2019, the MCAQD submitted a supplemental commitment letter for Rule 324 to address additional rule approvability comments MCAQD received after the original commitment letter was submitted. Based on the commitment letters, the EPA published a proposed conditional approval of Rules 323 and 324 in the Federal Register on December 30, 2019. The proposed conditional approval outlined EPA’s official rule approvability comments (“rule deficiencies”) which precluded full approval of the rules into the Arizona SIP. EPA’s final conditional approval was published on July 20, 2020. The effective date of the final rule was August 19, 2020. If the MCAQD, through the ADEQ, submits the rule revisions that the MCAQD has committed to submit within 12 months of the effective date of the final rule and the EPA approves the submission, then the identified deficiencies will be cured, and the rules will be approved as part of the Arizona SIP. A description of each rule, the specific deficiencies associated with each rule, the MCAQD’s proposed revisions to address the deficiencies for each rule, and the draft rules with strikethrough-underline are included in the two attached draft Notices of Final Rulemaking. Support/Opposition: During the rulemaking process, the MCAQD has received written feedback from four (4) stakeholders. The stakeholders did not express support nor opposition to the rulemaking. Staff Recommendation: Approve Board of Health Recommendation: Approve Additional Comments: This rulemaking is following procedures identified in state statutes and the Maricopa County Enhanced Regulatory Outreach Program (EROP) Policy. The County Manager briefed the Board of Supervisors regarding the rulemaking in December 2017. The Board of Health Meeting to initiate regulatory change for Rules 323 and 324 occurred on 7 February 25, 2019. Stakeholder workshops for Rule 323 were held on August 22, 2018 and September 23, 2020, and for Rule 324 were held on August 22, 2018 and October 24, 2019. Notices of Proposed Rulemaking for the two rules were posted on the EROP website on November 24, 2020. On April 26, 2021, the Board of Health made a recommendation to the Board of Supervisors to approve the revisions to Rules 323 and 324. A newspaper notice of the Board of Supervisors public hearing will be published in the Arizona Business Gazette on May 20, 2021 and May 27, 2021. This regulatory change will take effect immediately upon approval by the Board of Supervisors. Presented By: Philip A. McNeely, R.G., Director Prepared By: Planning and Analysis Division Attachments: Preamble required by Arizona Revised Statutes (A.R.S.) § 49- 471.07 (See the Draft Notice of Final Rulemaking) Rule 323 Rule 324 Summary of the proposed regulatory change (See Item 4 of the Draft Notice of Final Rulemaking) Rule 323 Rule 324 Analysis of input received during the process and how that input was responded to (See Item 9 of the Draft Notice of Final Rulemaking) Rule 323 Rule 324 Language of proposed regulatory change or amendment (See the Draft Notice of Final Rulemaking) Rule 323 Strikethrough-underline Version Clean Version Rule 324 Strikethrough-underline Version Clean Version Minutes from Board of Health meetings Copies of all written and electronic Stakeholder input EPA Region IX Air Division Technical Support Documents 8 Return to list of attachments DRAFT NOTICE OF FINAL RULEMAKING MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III – CONTROL OF AIR CONTAMINANTS RULE 323: FUEL BURNING EQUIPMENT FROM INDUSTRIAL/COMMERCIAL/INSTITUTIONAL (ICI) SOURCES The Maricopa County Air Quality Department (MCAQD) is proposing to amend Rule 323 (Fuel Burning Equipment from Industrial/Commercial/Institutional (ICI) Sources). The Control Officer is posting this Draft Notice of Final Rulemaking on the Maricopa County Enhanced Regulatory Outreach Program (EROP) website as part of the Report to the Board of Supervisors, in accordance with the Maricopa County EROP Policy. This notice includes the preamble, as prescribed in A.R.S. § 49-471.05, and the full text of the rule, including the intended actions to make new sections or amend, repeal, or renumber the sections of the rule. This notice also includes a list of all previous notices posted on the Maricopa County EROP website addressing the proposed rule and the concise explanatory statement prescribed in A.R.S. § 49-471.07, subsection B. PREAMBLE 1. Statutory authority for the rulemaking: A.R.S. §§ 49-112, 49-474, 49-479 and 49-480 2. Name and address of department personnel with whom persons may communicate regarding the rulemaking: Name: Scott Kahldon or Kimberly Butler Maricopa County Air Quality Department Planning and Analysis Division Address: 3800 N Central Avenue, Suite 1400 Phoenix, AZ 85012 Telephone: (602) 506-6010 Fax: (602) 506-6179 Email: AQPlanning@maricopa.gov Submit Comments At: http://maricopa.gov/FormCenter/Regulatory-Outreach-17/Citizen- Comments-94 3. Rulemaking process: This rulemaking (AQ-2017-007-Rule 323) is following procedures identified in state statutes and the Maricopa County EROP Policy: County Manager Briefing: December 2017 Stakeholder Workshops: August 22, 2018 September 23, 2020 Board of Health Meeting to Initiate Regulatory Change: February 25, 2019 Notice of Proposed Rulemaking: November 24, 2020 9 Return to list of attachments Board of Health Meeting to Recommend Approval to the Board of Supervisors: April 26, 2021 Board of Supervisors Formal Meeting to set the Public Hearing: May 19, 2021 Board of Supervisors Public Hearing: June 23, 2021 4. Explanation of the rule, including the control officer's reasons for initiating the rulemaking: Rule 323 (Fuel Burning Equipment from Industrial/Commercial/Institutional (ICI) Sources) limits emissions of nitrogen oxides (NOx), sulfur oxides (SOx), carbon monoxide (CO), and particulate matter (PM) from fuel burning equipment at industrial, commercial, and institutional (ICI) sources. The MCAQD is proposing to revise Rule 323 to address rule deficiencies identified by the U.S. Environmental Protection Agency (EPA) to secure full approval of Rule 323 as a revision to the Arizona State Implementation Plan (SIP). On May 4, 2016, portions of Maricopa County were designated as a moderate nonattainment area with respect to the 2008 National Ambient Air Quality Standards for Ozone. Sections 182(b)(2) and 182(f) of the Clean Air Act require jurisdictions that are classified as “moderate” or higher nonattainment to implement reasonably available control technology (RACT) for all categories of volatile organic compound (VOC) sources covered by a Control Technique Guideline document as well as for all major stationary sources of NOX and VOCs that are located within the nonattainment area. EPA defines RACT as “the lowest emission limitation that a particular source is capable of meeting by the application of control technology that is reasonably available considering technological and economic feasibility.” The EPA provides guidance on RACT for sources of NOX through Alternative Control Technology (ACT) documents which offer State and local air pollution control authorities information that assists in determining NOX-RACT for air quality rules. In addition, the EPA reviews SIP-approved air quality rules from other air districts with ozone nonattainment areas to assist in determining NOX-RACT for air quality rules. In November 2016, Rule 323 was revised to implement RACT for sources of NOX. The revised rule was submitted to the EPA in June of 2017, as part of the SIP Revision for the Maricopa County Air Quality Department Ozone Rules contained in the Arizona SIP. The EPA reviewed Rule 323 and provided the MCAQD with written rule approvability and rule improvement comments for the rule. EPA staff informed MCAQD staff they would be using a conditional approval process to act on Rule 323 and the MCAQD would need to draft a commitment letter outlining revisions to Rule 323 to address the rule approvability comments. On January 28, 2019, the MCAQD submitted a Letter of Commitment for Conditional Approval of the Maricopa County RACT SIP to the EPA. Based on the commitment letter, the EPA published a proposed conditional approval of Rule 323 in the Federal Register on December 30, 2019 (Docket ID; EPA-R09-OAR-2019-0321). The proposed conditional approval rulemaking was available for a 30-day comment period, but no comments were received. The proposed conditional approval references a Technical Support Document (TSD) which includes a thorough review of Rule 323 and MCAQD’s commitments. The TSD outlines EPA’s eight (8) official rule approvability comments (“rule deficiencies”) which preclude full approval of the rule into the SIP as well as one (1) rule revision 10 recommendation, which is not currently the basis for rule disapproval but is recommended for this current proposed rulemaking for Rule 323. Revisions addressing both the EPA’s identified deficiencies and recommendation have been made to the proposed draft Rule 323 (included in this notice). A link to EPA’s TSD is located under Section 5 of this notice. EPA’s final conditional approval was published on July 20, 2020. The effective date of the final rule was August 19, 2020. If the MCAQD, through the ADEQ, submits the rule revisions that the MCAQD has committed to submit within 12 months and the EPA approves the submission, then the identified deficiencies will be cured, and the rule will be approved as part of the Arizona SIP. Details about the EPA’s identified deficiencies and the MCAQD’s proposed remedies are described below, followed by the EPA rule recommendation and the MCAQD’s proposed revision to address the recommendation. Deficiency 1: The emergency fuel use exemptions in Section 104 are overly broad. To correct this, the MCAQD should clarify in this section that emergency fuel is only allowed under natural gas curtailments or natural gas emergencies. The MCAQD should further limit the total allowable length of emergency fuel burning to be consistent with other jurisdictions (see, Imperial County APCD Rule 400.1 Section D.3) Also, Rule 323 does not require that the facility owner/operator notify the MCAQD when switching to emergency fuel, which Rule 322 “Power Plant Operations” (which regulates similar types of combustion equipment) does. This is an enforceability issue. Finally, the language in section 104 exempting units firing emergency for testing purposes could be interpreted to allow for the exemption during any operating period so long as the there was a testing period. The MCAQD should clarify that the exemptions only apply during the testing period. Remedy 1: The MCAQD is proposing to clarify the exemptions for emergency fuel use only apply during natural gas curtailments and natural gas emergencies and for up to 36 cumulative hours per year for testing, reliability, training, and maintenance purposes. The MCAQD is proposing to add a requirement for the owner or operator to notify the MCAQD when switching to emergency fuel. Also, the MCAQD is proposing to limit the total allowable length of emergency fuel combustion during natural gas curtailments and natural gas emergencies to 168 hours per year per combustion unit (for combustion units located at a major stationary source of nitrogen oxides). Deficiency 2: All major sources of NOx must be subject to RACT limits or requirements. All turbines, and all boilers rated larger than 100 MMBtu/hr must comply with the limits in section 304. Boiler units rated between 10 MMBtu/hr and 100 MMBtu/hr may opt to comply with the limits in section 304, or tune the units annually as required in section 304.1. The burner maintenance requirements in section 304.1 are not RACT, as other jurisdictions regulating units in this size category are able to achieve numeric limits (down to 5 MMBtu/hr in Imperial County APCD Rule 400.2) or have more stringent tuning requirements (as seen in Ventura County APCD Rule 74.15.1 and South Coast AQMD Rule 1146, Attachment A). As the rule is written, major source units in the nonattainment area are only required to tune 11 the engine instead of complying with a RACT NOx limit. MCAQD must clarify that larger units (e.g. annual heat input rating of 50 MMBtu/hr or greater, and annual heat input of 220,000 therms or greater) shall comply with Rule 323 by meeting a NOx limit (as seen in San Diego County APCD Rule 69.2). Remedy 2: The MCAQD is proposing to extend the NOX emission limits to units greater than 50 MMBtu/hr for combustion units located at major sources of NOx. The MCAQD is also proposing to require combustion units rated greater than 10 MMBtu/hour and less than or equal to 50 MMBtu/hr with annual heat input greater than or equal to 220,000 therms to comply with the RACT emission limits or RACT tuning procedures for combustion units located at major sources of NOx. Deficiency 3: The NOx limits of 42 ppmv for gas fuel-fired operations and 65 ppmv for liquid fuel-fired operations for non-turbine combustion equipment in this rule are not consistent with other jurisdictions limits and are not RACT. Limits in other ozone nonattainment jurisdictions, such as Imperial County APCD Rule 400.2 and Sacramento Metropolitan AQMD, are set 30 ppmv and 40 ppmv for gas and liquid fuel-fired operations. Remedy 3: The MCAQD is proposing to add NOx emission limits for non-turbine combustion equipment of 30 ppmvdc when burning gaseous fossil fuel and 40 ppmvdc when burning liquid fossil fuel to meet RACT. Deficiency 4: Section 306 states that operators may comply with the limits in this rule by installing an ECS, and notes that such systems must be properly operated and maintained in accordance with an approved operations and maintenance plan. The rule language in section 306 could be interpreted to mean that the installation of an ECS on its own would allow compliance with the emission limits. However, an ECS that does not sufficiently reduce emissions could meet section 306’s requirement without any verification for meeting the other section 300 requirements. The effectiveness of such a system in meeting the applicable emission standards is unknown without a compliance determination requirement (which in section 503 only applies to sections 301-304, and only for units larger than 100 million Btu/hr). MCAQD must include language that states that an ECS or combustion control system must also be source tested to confirm compliance with the limit or create parametric monitoring requirements to put in the operation and maintenance plan. Alternatively, the rule language in section 306 should be clarified to not allow for the installation of an ECS to be an alternative to compliance with the RACT limits in sections 301-304. Remedy 4: The MCAQD is proposing to revise Section 503.2 to require performance testing for any unit that is subject to numeric emission limits in Section 301, 304 and/or 305. In addition, MCAQD is proposing to add Section 307.2.d which will require an O&M plan to contain 12 operating parameters to ensure the owner or operator continues to operate the ECS in the manner it was operated during the performance test. Deficiency 5: The operations and maintenance plan requirements are only approved by the Control Officer in section 306.3. This constitutes unacceptable director’s discretion. In addition, the rule allows the facility operator to change the operation and maintenance plan in section 306.3.d by submitting changes. MCAQD must revise this language to resolve these enforceability questions, either by removing this discretion, including the EPA in approval of these plans, or outlining clear criteria that must be met for approval. The operation and maintenance plan must include the control equipment manufacturer’s operation and maintenance guidelines. If the MCAQD chooses to revise section 306 so that installation of an emission control system does not result in automatic compliance with the emission limits in sections 301-304, then this discretion may be acceptable as a source test would be the primary determinant of compliance with RACT requirements. Remedy 5: The MCAQD is proposing to add Section 307.2 which outlines clear criteria that must be included in an O&M plan for approval by the Control Officer and also states that the O&M Plan must include the manufacturer’s recommended maintenance procedures and frequencies. In addition, MCAQD is proposing to revise Section 503 to require performance tests for any units that are subject to a numeric emission limit. Deficiency 6: Section 503.2 specifies that boilers larger than 100 MMBtu/hr must source test triennially but does not describe a testing frequency for other units. Other units must be tested at least triennially. MCAQD must also cite the appropriate test method from the list in section 500. Remedy 6: The MCAQD is proposing to revise Section 503.2 to require any combustion unit that is subject to numeric emission limits in Section 301, 304 and/or 305 to conduct performance tests in accordance with Rule 270 at least once every 5 years. In addition, MCAQD is proposing to add citations of the appropriate test methods in sections 503.2.a and 503.2.b. Deficiency 7: Section 200 of this rule and Maricopa’s Rule 100 General Provisions and Definitions does not include a definition for “boiler,” which is used throughout this rule, and in the context of definitions for “annual capacity factor,” “steam generating unit,” and others. For purposes of enforceability, such a definition is necessary. Remedy 7: The MCAQD is proposing to add a definition of “boiler”. Deficiency 8: 13 Section 200 also does not include a definition for “continuous emissions monitoring system.” For purposes of enforceability, such a definition is necessary. Remedy 8: The MCAQD is proposing to add a definition of “continuous emissions monitoring system”. Recommendation 1: Section 219 defines “steady state” This is defined as a “safe stable megawatt load”, which is the incorrect measure for non-EGU sources like general ICI sources which may not output power in megawatts. Revision 1: The MCAQD is proposing to remove the definition of “steady state”. 5. Studies relied on in the control officer's evaluation of or justification for the rule and where the public may obtain or review the studies, all data underlying the studies, any analysis of the studies and other supporting material. United States Environmental Protection Agency Region IX Air Division (2019), Technical Support Document for EPA’s Rulemaking for the Arizona State Implementation Plan Regarding Rule 323, “Fuel Burning Equipment from Industrial/Commercial/Institutional (ICI) Sources.” https://www.regulations.gov/document?D=EPA-R09-OAR-2019-0321-0011 6. An economic, small business and consumer impact statement: The following discussion addresses each of the elements required for an economic, small business and consumer impact statement, as prescribed by A.R.S. §§ 41-1055, subsections A, B and C, and 41-1035: An identification of the proposed rulemaking, including all of the following: This rulemaking is proposing to revise Rule 323. (a) The conduct and its frequency of occurrence that the rule is designed to change. The MCAQD is proposing to revise Rule 323 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 323 into the Arizona SIP. The revisions are explained in more detail in Item #4 of this notice. (b) The harm resulting from the conduct the rule is designed to change and the likelihood it will continue to occur if the rule is not changed. The MCAQD is proposing to revise Rule 323 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 323 into the Arizona SIP and avoid sanctions and imposition of a Federal Implementation Plan (FIP) under the Clean Air Act. (c) The estimated change in frequency of the targeted conduct expected from the rule change. 14 The MCAQD is proposing to revise Rule 323 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 323 into the Arizona SIP. As with other rules, the MCAQD will use education, outreach, and other compliance assurance tools to increase the number of people in compliance with the revised rule. The MCAQD strives to achieve the highest possible compliance rates. A brief summary of the information included in the economic, small business and consumer impact statement. The economic, small business and consumer impact statement addresses each of the elements required for an economic, small business and consumer impact statement, as prescribed by A.R.S. §§ 41-1055, subsections A, B, and C, and 41-1035. Name and address of agency employees who may be contacted to submit or request additional data on the information included in the economic, small business and consumer impact statement. Name: Scott Kahldon or Kimberly Butler Maricopa County Air Quality Department Planning and Analysis Division Address: 3800 N Central Avenue, Suite 1400 Phoenix, AZ 85012 Telephone: (602) 506-6010 Fax: (602) 506-6179 Email: AQPlanning@maricopa.gov Submit Comments At: http://maricopa.gov/FormCenter/Regulatory-Outreach-17/Citizen- Comments-94 An identification of the persons who will be directly affected by, bear the costs of or directly benefit from the proposed rulemaking. This rulemaking will directly affect industrial, commercial, and institutional sources in Maricopa County with combustion units that meet the applicability thresholds below: (1) Each boiler or steam generating unit that has a maximum design rated heat input capacity greater than 10 million (MM) British thermal units per hour (Btu/hr), (2) Each stationary gas turbine with a heat input at peak load equal to or greater than 10 MMBtu/hr, (3) Each co-generation steam generating unit with a heat input of greater than 10 MMBtu/hr, and (4) Each indirect-fired process heater with a heat input greater than 10 MMBtu/hr. A cost benefit analysis of the following: (a) The probable costs and benefits to the implementing agency and other agencies directly affected by the implementation and enforcement of the proposed rulemaking. This rulemaking should not impose any new costs on the MCAQD or on any other agencies affected by the proposed rulemaking. 15 (b) The probable costs and benefits to a political subdivision of this state directly affected by the implementation and enforcement of the proposed rulemaking. This rulemaking should not impose any significant new costs on political subdivisions of this state affected by the proposed rulemaking. (c) The probable costs and benefits to businesses directly affected by the proposed rulemaking, including any anticipated effect on the revenues or payroll expenditures of employers who are subject to the proposed rulemaking. The MCAQD is proposing to revise Rule 323 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 323 into the Arizona SIP for RACT and avoid sanctions and imposition of a FIP under the Clean Air Act. This rulemaking should not impose any significant new costs on businesses affected by the proposed rulemaking. The MCAQD anticipates that increased clarity provided by the Rule 323 revisions will provide a benefit to the regulated community; it will take less time for sources subject to the rule to understand and comply with the rule, which leads to increased compliance, and a decrease in costs of compliance to the regulated community. A general description of the probable impact on private and public employment in businesses, agencies and political subdivisions of this state directly affected by the proposed rulemaking. This rulemaking should have no impact on private or public employment in businesses, agencies, and political subdivisions of this state. A statement of the probable impact of the proposed rulemaking on small businesses. The statement shall include: (a) An identification of the small businesses subject to the proposed rulemaking. Small businesses subject to this rulemaking are industrial, commercial, and institutional sources in Maricopa County that have fuel burning equipment that meet the requirements of Section 102 of the draft rule included in this notice. (b) The administrative and other costs required for compliance with the proposed rulemaking. The MCAQD is proposing to revise Rule 323 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 323 into the Arizona SIP for RACT and avoid sanctions and imposition of a FIP under the Clean Air Act. The MCAQD does not anticipate the rule revisions will impose any significant new costs on small businesses subject to the proposed rule. (c) A description of the methods that the agency may use to reduce the impact on small businesses. i. Establish less stringent compliance or reporting requirements in the rule for small businesses. This rulemaking does not impose any significant new compliance requirements on small businesses and does not establish any significant new reporting requirements for small businesses. 16 ii. Establish less stringent schedules or deadlines in the rule for compliance or reporting requirements for small businesses. This rulemaking does not impose any significant new compliance requirements on small businesses and does not establish any significant new reporting requirements for small businesses. iii. Consolidate or simplify the rule's compliance or reporting requirements for small businesses. This rulemaking does not impose any significant new compliance requirements on small businesses and does not establish any significant new reporting requirements for small businesses. iv. Establish performance standards for small businesses to replace design or operational standards in the rule. This rulemaking is unlikely to impose any new design or operational requirements on small businesses. v. Exempt small businesses from any or all requirements of the rule. This rulemaking does not impose any significant new requirements on small businesses. (d) The probable cost and benefit to private persons and consumers who are directly affected by the proposed rulemaking. This rulemaking should not result in any significant costs for private persons and consumers. A statement of the probable effect on state revenues. The rulemaking will not impose increased monetary or regulatory costs on other state agencies, political subdivisions of this state, persons, or individuals so regulated. Without costs to pass through to customers, there is no projected change in consumer purchase patterns and, thus, no impact on state revenues from sales taxes. A description of any less intrusive or less costly alternative methods of achieving the purpose of the proposed rulemaking, including the monetizing of the costs and benefits for each option and providing the rationale for not using nonelected alternatives. The purpose of this rulemaking is to revise Rule 323 to remedy deficiencies identified by the EPA. This rule making is required to secure approval of Rule 323 into the State Implementation Plan (SIP) for RACT and avoid sanctions and imposition of a Federal Implementation Plan (FIP) under the Clean Air Act. A description of any data on which a rule is based with a detailed explanation of how the data was obtained and why the data is acceptable data. Not applicable. 7. The proposed effective date of the rule: The proposed effective date of this rulemaking is June 23, 2021. 17 8. Such other matters as are prescribed by statute and that are applicable to the county or to any specific rule or class of rules: Under A.R.S. § 49-479(C), a county may not adopt a rule or ordinance that is more stringent than the rules adopted by the Director of the Arizona Department of Environmental Quality (ADEQ) for similar sources unless it demonstrates compliance with the applicable requirements of A.R.S. §49-112. § 49-112 County regulation; standards § 49-112(A) When authorized by law, a county may adopt a rule, ordinance or regulation that is more stringent than or in addition to a provision of this title or rule adopted by the director or any board or commission authorized to adopt rules pursuant to this title if all of the following requirements are met: 1. The rule, ordinance or regulation is necessary to address a peculiar local condition. 2. There is credible evidence that the rule, ordinance or regulation is either; (a) Necessary to prevent a significant threat to public health or the environment that results from a peculiar local condition and is technically and economically feasible. (b) Required under a federal statute or regulation or authorized pursuant to an intergovernmental agreement with the federal government to enforce federal statutes or regulations if the county rule, ordinance or regulation is equivalent to federal statutes or regulation. 3. Any fee or tax adopted under the rule, ordinance or regulation does not exceed the reasonable costs of the county to issue and administer the permit or plan approval program. § 49-112(B) When authorized by law, a county may adopt rules, ordinances or regulations in lieu of a state program that are as stringent as a provision of this title or rule adopted by the director or any board or commission authorized to adopt rules pursuant to this title if the county demonstrates that the cost of obtaining permits or other approvals from the county will approximately equal or be less than the fee or cost of obtaining similar permits or approvals under this title or any rule adopted pursuant to this title. If the state has not adopted a fee or tax for similar permits or approvals, the county may adopt a fee when authorized by law in the rule, ordinance or regulation that does not exceed the reasonable costs of the county to issue and administer that permit or plan approval program. The MCAQD is in compliance with A.R.S. §§ 49-112 (A) and (B). Rule 323 meets A.R.S. § 49-112 (A) (1) by demonstrating that the rule is necessary to address a peculiar local condition, in that Maricopa County fails to meet the 8-hour NAAQS for ozone. Rule 323 meets the requirements of A.R.S. § 49-112 (A) (2) (b), in that Maricopa County is required by federal law to revise existing rules to address RACT for industrial, commercial, and institutional sources that have fuel burning equipment. As there is no new fee or tax associated with this proposed rulemaking, the MCAQD also affirms that Rule 323 meets the requirements of A.R.S. § 49-112 (A) (3) and A.R.S. § 49-112 (B). 18 9. List of all previous notices posted to the Maricopa County EROP website addressing the proposed rule and a concise explanatory statement, as prescribed by A.R.S. § 49- 471.07, subsection B: (a) List of all previous notices posted to the Maricopa County EROP website addressing the proposed rule: Notice Date of Posting Briefing Notification to County Manager: January 26, 2018 Notice of Stakeholder Workshop: August 03, 2018 September 09, 2020 Notice of Board of Health Meeting to Initiate February 08, 2019 Regulatory Change: Notice of Proposed Rulemaking: November 24, 2020 Notice of Board of Health Meeting to Make Recommendations to the Board of Supervisors: April 12, 2021 (b) The following discussion addresses each of the elements required for a concise explanatory statement, as prescribed by A.R.S. § 49-471.07, subsection B: i. A description of any change between the proposed rule or ordinance, the final rule or ordinance or notice of final supplemental rule or ordinance. The following changes were made after the Notice of Proposed Rulemaking was published on November 24, 2020. 1. The MCAQD revised the definition of Parts Per Million By Volume Dry (PPMVD) to be consistent between Rules 322, 323, and 324. The section was revised as indicated below: Section 219: PARTS PER MILLION BY VOLUME DRY(PPMVD): A unit of proportion used to express concentration that is corrected to a dry basis. 2. Based off of staff comments, the MCAQD removed the oxygen corrections “corrected to 15% oxygen” and “corrected to 3% oxygen” from the definition of Parts Per Million By Volume Dry and placed them closer to the corresponding emission limits to improve rule clarity. Section 304.2 and Section 305 were revised as indicated below: Section 304.2: RACT Emission Limits: Limit nitrogen oxide emissions to no more than the following amounts: a Stationary Gas Turbines: (1) 42 ppmvd corrected to 15% oxygen calculated as nitrogen dioxide, when burning gaseous fuel. (2) 65 ppmvd corrected to 15% oxygen calculated as nitrogen dioxide, when burning liquid fuel. b. All Combustion Units Except Stationary Gas Turbines: 19 (1) 30 ppmvd corrected to 3% oxygen calculated as nitrogen dioxide, when burning gaseous fuel. (2) 40 ppmvd corrected to 3% oxygen calculated as nitrogen dioxide, when burning liquid fuel. Section 305: LIMITATIONS-CARBON MONOXIDE: An owner or operator of any combustion unit with a heat input greater than 100 MMBtu/hr shall not cause to be discharged into the atmosphere, carbon monoxide (CO), measured in excess of 400 ppmvd corrected to 15% oxygen for Stationary Gas Turbines, and corrected to 3% oxygen for all Combustion Units Except Stationary Gas Turbines. 3. The MCAQD removed the language “in accordance with the requirements of Rule 270 of these rules” in section 503.2. The section was revised as indicated below: Section 503.2: Source Test Requirements: The owner or operator of any combustion unit that is subject to numeric emission limits in Section 301, 304 and/or 305 of this rule shall conduct performance tests at least once every 5 years. The result of the performance test shall be the arithmetic mean of the results of three test runs. Each test run shall have a minimum sample time of one hour. In addition, the owner or operator shall comply with the following requirements: 4. Based off of staff comments, the MCAQD added the language “Monthly records” in section 501.1 and added the language “and amount” in section 501.2 to clarify tracking fuel use and standardizing language between the two sections. Section 501.1 and Section 501.2 were revised as indicated below: Section 501.1: Combustion Units: Monthly records of type and amount of fuel used, and the sulfur content of any liquid fuel or waste derived fuel gas combusted. Section 501.2: Emergency Fuel Usage: Monthly records of type and amount of emergency fuel used, the sulfur content of the fuel, dates and hours of operation using emergency fuel, and nature of the emergency or purpose for the use of the emergency fuel as stated in Sections 104.2 and 104.3. Yearly records of the twelve month log of hours of operation using emergency fuel. ii. A summary of the comments and arguments for and against the notice and the county’s response to the comments and arguments. Return to list of attachments The following discussion evaluates the arguments for and against the rule and includes responses to comments received on the proposed rule or the preamble in the Notice of Proposed Rulemaking. The MCAQD received written comments from two (2) stakeholders. All of the comments were reviewed and evaluated by the MCAQD. Comment #1: This rule contains similar requirements for tracking fuel use and days/hours of operation. I would like to request the same change as stated above (for R322, section 501.1 - This rule now requires records of the type and amount of fuel 20 used, sulfur content and days and hours of operation. I would like to remove the requirement to track days and hours of operation and that fuel use be required to be tracked monthly. Fuel tracking monthly makes the most sense since invoices are typically sent monthly (in the case of natural gas). I have been unable to identify a reason to track days and hours of operation. This information does not appear to be needed to determine compliance). Response #1: The MCAQD considered your comment and deleted the requirement for days and hours of operation. In addition, the MCAQD clarified that fuel usage be tracked monthly. Comment #2: In Maricopa County’s (the County) workshop presentation, the County recommends accepting the more stringent boiler tuning requirements and suggests requirements based rated capacity and whether or not the source was at a major source. Concerning the County’s recommendations for altering requirements based on rated capacity of the unit, APS suggests an alternative. APS has reviewed EPA’s comment and believe EPA was intending to apply RACT to “major source units” (units emitting 100 tons/yr of NOx) and not a minor source unit at a “major source” as suggested by the County’s proposed commitment. APS requests that RACT requirements only apply to major source units. Applying a major source applicability limit would be consistent with EPA’s recommendation with Rule 322. APS owns a Clayton Boiler rated at 11 MBtu/hr, which emits approximately 25 lbs per year. APS has reviewed the examples for boiler tuning requirements and find them excessive in some situations for simple and small units. Multiple items in the referenced boiler tuning requirements could not work for this unit. APS doesn't support more stringent requirements for the smaller units. At a minimum, there should be language that accommodate the size and design of the unit. Response #2: The MCAQD considered your comment and developed a table that clearly outlines which combustion units at a major source of NOx must comply with RACT requirements, see Table 323-1 in the draft rule. Some smaller combustion units, units greater than 10 MMBtu/hour and less than or equal to 50 MMBtu/hour with annual heat input less than 220,000 therms, will not have to comply with RACT requirements. Return to list of attachments EXACT WORDING OF THE RULE MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III – CONTROL OF AIR CONTAMINANTS RULE 323 FUEL BURNING EQUIPMENT FROM INDUSTRIAL/COMMERCIAL/INSTITUTIONAL (ICI) SOURCES INDEX SECTION 100 – GENERAL 21 101 PURPOSE 102 APPLICABILITY 103 EXEMPTIONS 104 PARTIAL EXEMPTIONS SECTION 200 – DEFINITIONS 201 ALTERNATIVE FUELS 202 ANNUAL HEAT INPUT 203 BOILER 202 204 COGENERATION STEAM GENERATING UNIT 205 COMBUSTION CONTROL SYSTEM 206 COMBUSTION UNIT 207 CONTINUOUS EMISSIONS MONITORING SYSTEM (CEMS) 203 208 CORRECTIVE ACTION PLAN (CAP) 204 DISTILLATE OIL 205 209 EMERGENCY FUEL 206 210 EMISSION CONTROL SYSTEM (ECS) 207 211 FOSSIL FUEL 212 GAS TURBINE 208 213 HEAT INPUT 214 LOW SULFUR OIL 209 215 NATURAL GAS CURTAILMENT 210 216 OPACITY 217 OPERATING HOUR 211 218 PARTICULATE MATTER EMISSIONS 219 PARTS PER MILLION BY VOLUME DRY (PPMVD) 212 220 PEAK LOAD 213 221 PROCESS HEATER 214 222 RATED HEAT INPUT CAPACITY 215 REGENERATIVE CYCLE GAS TURBINE 216 RESIDUAL OIL 217 SIMPLE CYCLE GAS TURBINE 218 223 STATIONARY GAS TURBINE 219 STEADY STATE 22 220 224 STEAM GENERATING UNIT 221 225 SULFUR OXIDES (SOX) 222 226 ULTRA LOW SULFUR OILDIESEL 223 227 UNCOMBINED WATER 224 228 WASTE DERIVED FUEL GAS 225 229 WATER HEATER SECTION 300 – STANDARDS 301 LIMITATIONS - PARTICULATE MATTER 302 LIMITATIONS - OPACITY 303 LIMITATIONS - SULFUR IN FUEL 304 LIMITATIONS - NITROGEN OXIDES 305 LIMITATIONS - CARBON MONOXIDE 306 GOOD COMBUSTION PRACTICES FOR STATIONARY GAS TURBINES 306 307 REQUIREMENTS FOR AIR POLLUTION CONTROL EQUIPMENT ECS AND ECS MONITORING EQUIPMENT 308 EMERGENCY FUEL USE NOTIFICATION SECTION 400 – ADMINISTRATIVE REQUIREMENTS 401 COMPLIANCE SCHEDULE FOR PERFORMANCE TESTING 402 COMPLIANCE SCHEDULE FOR RACT TUNING PROCEDURE SECTION 500 – MONITORING AND RECORDS 501 RECORDKEEPING AND REPORTING 502 RECORDS RETENTION 503 COMPLIANCE DETERMINATION DEMONSTRATION 504 COMPLIANCE DETERMINATION-TEST METHODS INCORPORATED BY REFERENCE APPENDIX A TO RULE 323 23 Adopted 07/02/2003; Revised 10/17/2007; Revised 11/02/2016; Revised MM/DD/YYYY MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III-CONTROL OF AIR CONTAMINANTS RULE 323 FUEL BURNING EQUIPMENT FROM INDUSTRIAL/COMMERCIAL/INSTITUTIONAL (ICI) SOURCES SECTION 100 – GENERAL 101 PURPOSE: To limit the discharge of nitrogen oxides, sulfur oxides, carbon monoxide, and particulate matter emissions into the atmosphere from fuel burning combustion equipment units at industrial and/or commercial and/or institutional (ICI) sources. 102 APPLICABILITY: This rule applies to the following types of ICI combustion equipment units that burns burn either fossil fuels or alternative fuels: 102.1 Each boiler or steam generating unit that has a maximum design rated heat input capacity from fuels combusted in the generating unit of greater than 10 million (MM) British thermal units per hour (Btu/hr)(2.9 Megawatts (MW)). 102.2 Each stationary gas turbine with a heat input at peak load equal to or greater than 2.9 megawatts (MW) 10 MMBtu/hr. 102.3 Each cogeneration steam generating unit with a heat input of greater than 10 MMBtu/hr. 102.4 Each indirect-fired process heater with a heat input greater than 10 MMBtu/hr. 102.5 NSPS & NESHAP: In addition to this rule, facilities may be subject to New Source Performance Standards (NSPS) in Rule 360 and/or National Emission Standards for Hazardous Air Pollutants (NESHAP) in Rule 370 of these rules. 103 EXEMPTIONS: This rule shall not apply to the following types of equipment: 103.1 Incinerators, crematories, or burn-off ovens; or 103.2 Dryers, cement and lime kilns; or 103.3 Direct-fired process heaters; or 103.4 Medical waste incinerators; or 103.5 Reciprocating internal combustion equipment engines; or 103.6 Combustion equipment used in power plant operations for the purpose of supplying greater than one third of the electricity to any utility power distribution system for sale; or 103.7 Combustion equipment associated with nuclear power plant operations; or 103.8 Water heaters used for the sole purpose of heating hot water for comfort or for radiant heat; or 24 103.9 Municipal solid waste landfill enclosed combustors and non-enclosed flares. 104 PARTIAL EXEMPTIONS: 104.1 Stationary gas turbines listed in Section 102.2 of this rule that are used for any of the following reasons shall be exempt from Sections 301.1, 301.2, 301, 304, and 305, 501.1, and 501.3 of this rule: a. Used for firefighting; or b. Used for flood control; or c. Engaged by manufacturers in research and the development of equipment for either gas turbine emission control techniques or gas turbine efficiency improvements; or. d. Fired with emergency fuel that is normally fired with natural gas, or e. Fired with emergency fuel for 36 cumulative hours per year or less, per unit for testing, reliability, training, and maintenance purposes as allowed by a permit issued by the Control Officer for that source. 104.2 All steam generating units including cogeneration units and process heaters All combustion units that are normally fired with natural gas that are used for any of the following reasons as allowed by a permit issued by the Control Officer shall be exempt from Sections 301, 304, 305, and 501.1 and 501.3 of this rule: while firing emergency fuel during a natural gas curtailment or a natural gas emergency. For combustion units located at a major stationary source of nitrogen oxides, this exemption shall not exceed 168 hours per calendar year per combustion unit, excluding hours of operation for testing, reliability, training, and maintenance. a. Fired with an emergency fuel that is normally fired with natural gas; or b. Firing any emergency fuel for testing, reliability, and maintenance purposes for 36 cumulative hours per year, per unit or less. 104.3 All combustion units that are normally fired with natural gas shall be exempt from Sections 301, 304, 305, and 501.1 of this rule while firing emergency fuel for the purposes of testing, reliability, training, and maintenance. This exemption shall not exceed 36 hours per calendar year per combustion unit, excluding hours of operation during natural gas curtailments and natural gas emergencies. SECTION 200 – DEFINITIONS: For the purpose of this rule, the following definitions shall apply, in addition to those definitions found in Rule 100 (General Provisions and Definitions) of these rules. In the event of any inconsistency between any of the Maricopa County air pollution control rules, the definitions in this rule take precedence. 201 ALTERNATIVE FUELS: Substitutes for traditional oil-derived and fossil-fuel derived motor vehicle fuels including but not limited to biodiesel, propane, ethanol, or methanol, or waste derived fuel gas. 202 ANNUAL HEAT INPUT: The actual total heat input of fuels combusted in a unit during a calendar year, as calculated based on the amount of each fuel combusted and the higher heating value of each fuel. Annual heat input shall not include the heat input from 25 emergency fuel combusted during natural gas curtailments and natural gas emergencies or emergency fuel combusted for purposes of testing, reliability, training, and maintenance as long as the usage limits in Sections 104.2 and 104.3 are not exceeded. 203 BOILER: A device that combusts any fossil fuel or alternative fuel and recovers thermal energy to heat water or another material. 202 204 COGENERATION STEAM GENERATING UNIT: A steam or hot water generating unit Any device that is fired with fossil fuels or alternative fuels and simultaneously produces both useful thermal energy (such as heat or steam) and either electrical (or mechanical energy) and thermal energy (such as heat or steam) from the same primary energy source. 205 COMBUSTION CONTROL SYSTEM: Equipment or technology, such as water injection or low-NOX burners, that reduce the formation of nitrogen oxides during combustion of fossil fuels or alternative fuels. 206 COMBUSTION UNIT: Any boiler, steam generating unit, stationary gas turbine, cogeneration steam generating unit, or indirect-fired process heater listed in Section 102 of this rule. 207 CONTINUOUS EMISSIONS MONITORING SYSTEM (CEMS): The total equipment required to sample, analyze, measure, and provide a permanent record of emissions by means of readings recorded at least once every 15 minutes (using an automated data acquisition and handling system (DAHS)). 203 208 CORRECTIVE ACTION PLAN (CAP): A methodical procedure that is used to evaluate and correct a turbine operational problem and that includes, at a minimum, improved preventative maintenance procedures, improved ECS operating practices, possible operational amendments, and progress reports. 204 DISTILLATE OIL: A petroleum fraction of fuel oil produced by distillation that complies with the specifications for fuel oil numbers 1 or 2, as defined by the American Society for Testing and Materials in ASTM D396-01, “Standard Specification for Fuel Oils.” 205 209 EMERGENCY FUEL: Fuel fired by a gas combustion unit, normally fueled by natural gas, only during circumstances of unforeseen disruption or interruption in the supply of natural gas to a unit that normally runs on natural gas. The inability to burn natural gas may be one of the following, but is not limited to, natural gas emergency, natural gas curtailment, or a breakdown of the delivery system. Fuel fired only for purposes of testing, reliability, training, and maintenance or during circumstances such as a natural gas emergency or a natural gas curtailment, or breakdown of delivery system such as an unavoidable interruption of supply that makes it impossible to fire natural gas in the combustion unit. Fuel is not considered emergency fuel if it is used to avoid either peak demand charges or high gas prices during on-peak price periods or due to a voluntary reduction in natural gas usage. 206 210 EMISSION CONTROL SYSTEM (ECS): A system approved in writing by the Control Officer, designed and operated in accordance with good engineering practice to reduce emissions. Post-combustion systems that are approved in writing by the Control Officer and are designed and operated in accordance with good engineering practice to reduce emissions 26 from combustion equipment. A combustion control system is not an emission control system. 207 211 FOSSIL FUEL: Naturally occurring carbonaceous substances from the ground such as natural gas, petroleum, coal, and any form of solid, liquid or gaseous fuel derived from such material for the purpose of creating energy. 212 GAS TURBINE: A rotary engine driven by the expansion of hot gases that are generated by the combustion of fuel. 208 213 HEAT INPUT: Heat derived from the combustion of fuel not including the heat input from preheated combustion air, recirculated flue gases, or exhaust gases from other sources, such as gas turbines, internal combustion engines, and kilns. 214 LOW SULFUR OIL: Fuel oil containing less than or equal to 0.05% sulfur by weight. 209 215 NATURAL GAS CURTAILMENT: A shortage in the supply of natural gas, due solely to limitations or restrictions in distribution pipelines by the utility supplying the gas and not due to the cost of natural gas. 210 216 OPACITY: A condition of the ambient air, or any part thereof, in which an air contaminant partially or wholly obscures the view of an observer. 217 OPERATING HOUR: A clock hour during which a unit combusts fuel, either for part of the hour or for the entire hour. 211 218 PARTICULATE MATTER EMISSIONS: Any and all particulate matter emitted to the ambient air as measured by applicable state and federal test methods. 219 PARTS PER MILLION BY VOLUME DRY (PPMVD): A unit of proportion used to express concentration that is corrected to a dry basis. 212 220 PEAK LOAD: 100% of the manufacturer’s design capacity of a gas turbine at 288° Kelvin, 60% relative humidity, and 101.3 kilopascals pressure (ISO 3977 standard day reference conditions and ratings). 213 221 PROCESS HEATER: An enclosed combustion device that uses controlled flame to transfer heat to a process fluid or a process material that is not a fluid or to heat transfer material for use in a process unit (not including the generation of steam). A process heater may be either indirect or direct-fired, dependent upon whether the gases of combustion mix with and exhaust to the same stack or vent (direct-fired) with gases emanating from the process material or not (indirect-fired). Emissions from indirect-fired units consist entirely of products of combustion while emissions from direct-fired units are unique to the given process and may vary widely in any industrial process. A process heater is not an oven or kiln used for drying, curing, baking, cooking, calcining, or vitrifying. 214 222 RATED HEAT INPUT CAPACITY: The heat input capacity in million Btu/hr. as specified on the nameplate of the combustion unit. If the combustion unit has been altered or modified so that its maximum heat input is different than the heat input capacity on the 27 nameplate (design heat capacity), the maximum heat input shall be considered as the rated heat input capacity. 215 REGENERATIVE CYCLE GAS TURBINE: Any stationary gas turbine that recovers thermal energy from the exhaust gases and utilizes the thermal energy to preheat air prior to entering the combustor unit. 216 RESIDUAL OIL: The heavier oils that remain after the distillate oils and lighter hydrocarbons are distilled off in refinery operations. This includes crude oil or fuel oil numbers 1 and 2 that have a nitrogen content greater than 0.05% by weight, and all fuel oil numbers 4, 5 and 6, as defined by the American Society of Testing and Materials in ASTM D396-01, “Standard Specifications for Fuel Oils”. 217 SIMPLE CYCLE GAS TURBINE: Any stationary gas turbine that does not recover heat from the gas turbine exhaust gases to preheat the inlet combustion air to the gas turbine, or that does not recover heat from the gas turbine exhaust gases to heat water or generate steam. 218 223 STATIONARY GAS TURBINE: Any simple cycle gas turbine or regenerative gas turbine that is not self-propelled or that is attached to a foundation. 219 STEADY STATE: A safe, stable megawatt load at which a unit with equipment in normal operating conditions is capable of being held for an extended period of time, without creating an unsafe or unstable operating condition. 220 224 STEAM GENERATING UNIT: An external combustion unit or boiler fired by fossil fuel that is used to generate hot water or steam. The hot water or steam is then used as energy for driving another process or piece of equipment. A device that combusts any fossil fuel or alternative fuel and produces steam or heats water or heats any heat transfer medium. 221 225 SULFUR OXIDES (SOX): The sum of the oxides of sulfur emitted from the flue gas from a combustion unit that are directly dependent upon the amount of sulfur in the fuel used. 222 226 ULTRA LOW SULFUR DIESEL OIL: Fuel oil containing less than or equal to 0.0015 % sulfur by weight. 223 227 UNCOMBINED WATER: Condensed water containing no more than analytical trace amounts of other chemical elements or compounds. 224 228 WASTE DERIVED FUEL GAS: A gaseous fuel that is generated from the biodegradation of solid or liquid waste including, but not limited to, digester gas and landfill gas. 225 229 WATER HEATER: A closed vessel in which water is heated by combustion of fuel and water is either withdrawn for use external to the vessel (at pressures not exceeding 160 psi with all controls and devices preventing water temperatures from exceeding 210°F) or used for radiant heat. Water heaters are usually no larger than 1 MM Btu/hr as opposed to boilers, and do not reach temperatures of 220°F and higher that boilers can reach, and are not manufactured to meet boiler codes. 28 SECTION 300 – STANDARDS 301 LIMITATIONS – PARTICULATE MATTER: An owner or operator of any combustion unit with either a rated heat input capacity or heat input greater than 100 MMBtu/hr shall not discharge, cause, or allow the discharge of particulate matter emissions, caused by combustion of non-gaseous liquid fuels or a blend of liquid fuels with other fuels, in excess of 0.10 pounds/MMBtu. 301.1 Limitation-Liquid Fuels: An owner or operator shall not discharge, cause or allow the discharge of particulate matter emissions, caused by combustion of non-gaseous liquid fuels or a blend of liquid fuels with other fuels in excess of 0.10 lbs. per MMBtu, during steady state operations, from any combustion units listed in Sections 102.1, 102.3, and 102.4 of this rule with either a rated heat input capacity or heat input of greater than 100 MM Btu/hr. 301.2 Particulate Matter Testing: A backhalf analysis shall be performed, using Reference Method 202 referenced in Section 504.6 of this rule, each time a compliance test for particulate matter emissions to meet the standards in Section 301.1 of this rule is performed using Method 5. (The results of the Method 202 testing shall be used for emissions inventory purposes). 301.3 Good Combustion Practices for Turbines: During steady state operations, an owner or operator of a stationary gas turbine listed in Section 102.2 of this rule, regardless of fuel type or size, shall use operational practices recommended by the manufacturer and parametric monitoring that ensure good combustion control. One of the following procedures may be used: a. Monitor the maximum temperature differential across the combustion burners or at locations around the back end of the turbine, dependent upon the particular unit, to ensure no more than a 100 F difference using a thermocouple. Differential temperatures across the burners to demonstrate good combustion practices shall be measured from at least one minute data point during a complete steady state operating hour. If a valid maximum temperature differential of greater than 100F is observed across the burners, investigation and corrective action shall be taken within three hours to reduce the temperature difference to 100F or less; or b. If the manufacturer recommends that the maximum numerical temperature differential to ensure good combustion is a temperature that is greater than 100°F, then proof of this maximum alternate temperature shall be submitted to the Control Officer. The procedure to measure the maximum temperature differential listed above in Section 301.3(a) of this rule shall then be followed using the alternate recommended maximum temperature differential after approval by the Control Officer. c. If a repetitive pattern of failure to meet the proper temperature differential of 100°F or to meet the alternate temperature differential recommended by the manufacturer indicates that the turbine is not being operated in a manner consistent with good combustion practices, then the Control Officer may require the owner or operator to submit a Corrective Action Plan (CAP). 29 302 LIMITATIONS – OPACITY: An owner or operator shall not discharge into the ambient air from any single source of emissions any air contaminant, other than uncombined water, in excess of 20% opacity. 303 LIMITATIONS – SULFUR IN FUEL: An owner or operator of any applicable equipment listed in Section 102 of this rule combustion unit that burns liquid fuel oil or a mixture or blend of fuel oil with any other fuels shall use only ultra low sulfur diesel oil. An existing supply of low sulfur oil purchased or obtained prior to November 2, 2016 may be used until depleted. An owner or operator using of any combustion unit that burns waste derived fuel gas shall use only waste derived fuel gas that contains no more than 0.08% sulfur by weight, alone or in combination with other fuels. 304 LIMITATIONS – NITROGEN OXIDES: An owner or operator of any combustion unit shall comply with the subsections specified in Table 323-1. TABLE 323-1 FOR COMBUSTION UNITS THAT ARE NOT THE OWNER OR LOCATED AT A MAJOR SOURCE OF OPERATOR SHALL NITROGEN OXIDES: COMPLY WITH: Stationary gas turbines 304.1 and 304.2 Combustion units (>100 MMBtu/hr) except stationary gas 304.3 turbines Combustion units (≤ 100 MMBtu/hr) except stationary gas 304.1 or 304.2 or 304.4* turbines FOR COMBUSTION UNITS THAT ARE THE OWNER OR LOCATED AT A MAJOR SOURCE OF OPERATOR SHALL NITROGEN OXIDES: COMPLY WITH: Stationary gas turbines 304.1 and 304.2 Combustion units (> 100 MMBtu/hour) except stationary 304.3 gas turbines Combustion units (> 50 MMBtu/hour and ≤ 100 304.2 MMBtu/hour) except stationary gas turbines Combustion units (> 10 MMBtu/hour and ≤ 50 304.2 or 304.4* MMBtu/hour with annual heat input ≥ 220,000 therms) except stationary gas turbines Combustion units (> 10 MMBtu/hour and ≤ 50 304.1 or 304.2 or 304.4* MMBtu/hour with annual heat input < 220,000 therms) except stationary gas turbines * The RACT tuning procedures in Section 304.4 are not appropriate for combustion units equipped with Low- NOX burners or burners utilizing a premix flame. 304.1 An owner or operator of any combustion equipment listed in Section 102 of this rule, except gas turbines, with a heat input of greater than 10 MMBtu/hr to 100 MMBtu/hr shall comply either with Sections 304.1(a) or 304.1(b) of this rule. Gas turbines are subject to both Sections 304.1(a) and 304.1(b) of this rule below: a. 304.1 Baseline Monitoring and Annual Tuning: a. Establish and record the initial optimal baseline concentrations for NOX and CO within 90 days of the first usage of the combustion equipment unit utilizing the 30 initial design burner specifications or manufacturer’s recommendations to ensure good combustion practices. The initial design burner specifications or manufacturer’s recommendations shall be kept onsite and available to the Control Office upon request. b. Tune the combustion unit annually in accordance with good combustion practices or follow the manufacturer’s recommended procedure, if applicable. The manufacturer’s recommended procedures shall be kept onsite and available to the Control Officer upon request. For low emission burner systems that do not provide accessibility for combustion chamber inspection, burner inspection, or inspection of the flame pattern, an owner or operator shall provide documentation from the manufacturer and follow the manufacturer’s recommended procedure. If using good combustion practices the manufacturer’s recommended tuning procedure is not available, the owner or operator shall tune the combustion unit annually include the by following, at a minimum, the steps listed in 304.1b.(1) – (5), if the combustion unit is so equipped, and if such procedures are appropriate to the type of combustion unit: (1) Inspect the burner system and clean and replace any components of the burner as necessary to minimize emissions of NOX and CO; and (2) Inspect the burner chamber for areas of impingement and remove if necessary; and (3) Inspect the flame pattern and make adjustments as necessary to optimize the flame pattern; and (4) Inspect the system controlling the air-to-fuel ratio and ensure that it is correctly calibrated and functioning properly; and (5) Measure the NOX and the CO concentration of the effluent stream after each adjustment was made with a handheld portable monitor to ensure optimal baseline concentrations are maintained. Using a portable monitor, measure the NOX and CO concentration of the effluent stream after each adjustment is made to ensure optimal baseline concentrations are maintained. b. 304.2 RACT Emission Limits: Limit nitrogen oxide emissions to no more than the following amounts: (1) a. Stationary Gas Turbines: (1) 42 ppmdv ppmvd corrected to 15% oxygen calculated as nitrogen dioxide, when burning gaseous fuel. During steady state operations, this test result using EPA Reference Method(s) 7 or other EPA-approved test method designated by the Control Officer shall be based upon the arithmetic mean of the results of three test runs. Each test run shall have a minimum sample run time of one hour. (2) (2) 65 ppmdv ppmvd corrected to 15% oxygen calculated as nitrogen dioxide, when burning liquid fuel. During steady state operations, this test result using EPA Reference Method(s) 7 or other EPA-approved test method designated by the Control Officer shall be based upon the arithmetic mean of the results 31 of three test runs. Each test run shall have a minimum sample run time of one hour. b. All Combustion Units Except Stationary Gas Turbines: (1) 30 ppmvd corrected to 3% oxygen calculated as nitrogen dioxide, when burning gaseous fuel. (2) 40 ppmvd corrected to 3% oxygen calculated as nitrogen dioxide, when burning liquid fuel. c. For simple gas turbines, the nitrogen oxides shall be measured dry and corrected to 15% oxygen, during steady state operations. For all other combustion equipment, the nitrogen oxides shall be measured dry and corrected to 3% oxygen. 304.2 304.3 Semi-Annual Tuning and RACT Emission Limits: An owner or operator of any combustion equipment, listed in Section 102 of this rule, with a heat input greater than 100 MMBtu/hr, shall: a. Tune the equipment combustion unit every 6 months in accordance with good combustion practices or a the manufacturer’s recommended procedure that at a minimum includes the or in accordance with the procedures listed in Section 304.1(a) 304.1.b(1) through (5) of this rule and; b. Meet the NOX RACT emission limits as stated in Section 304.1(b) 304.2 of this rule. 304.4 RACT Tuning Procedures: Tune the combustion unit every 12 months using the procedure in Appendix A of this rule that is appropriate for the combustion unit. 305 LIMITATIONS-CARBON MONOXIDE: An owner or operator of any equipment listed in Section 102 of this rule combustion unit with a heat input greater than 100 MMBtu/hr shall not cause to be discharged into the atmosphere, carbon monoxide (CO), measured in excess of 400 ppmv ppmvd corrected to 15% oxygen for Stationary Gas Turbines, and corrected to 3% oxygen for all Combustion Units Except Stationary Gas Turbines.at any time. During steady state operations, this test result, using EPA Reference Method 10 or other EPA-approved test method designated by the Control Officer, shall be based upon the arithmetic mean of the results of three test runs and shall be measured during steady state compliance source testing. Each test run shall have a minimum sample time of one hour. For simple gas turbines, the CO shall be measured dry and corrected to 15% oxygen, during steady state operations. For all other combustion equipment, the CO shall be measured dry and corrected to 3% oxygen. 306 GOOD COMBUSTION PRACTICES FOR STATIONARY GAS TURBINES: The owner or operator of any stationary gas turbine listed in Section 102.2 of this rule shall, regardless of fuel type, use operational practices recommended by the manufacturer to ensure good combustion control. The owner or operator of any stationary gas turbine listed in Section 102.2 of this rule shall demonstrate good combustion control using the parametric monitoring method listed below, or by operating a continuous emissions monitoring system to demonstrate compliance with the limits in Sections 304 and 305 of this rule, as applicable. 32 306.1 Monitor the maximum temperature differential across the combustion burners or at locations around the back end of the turbine, dependent upon the particular unit, to ensure no more than a 100F difference using a thermocouple. Differential temperatures shall be measured and recorded at least once during every operating hour. If a temperature differential of greater than 100F is observed across the burners, investigation and corrective action shall be taken within three hours to reduce the temperature difference to 100F or less. 306.2 If the manufacturer recommends that the maximum numerical temperature differential to ensure good combustion is greater than 100°F, then proof of this maximum alternate temperature differential shall be submitted to the Control Officer. The procedure to measure the maximum temperature differential listed in Section 306.1 of this rule shall then be followed using this alternate recommended maximum temperature differential after approval by the Control Officer. 306.3 If the differential temperature exceeds 100°F, or the alternate temperature differential recommended by the manufacturer and approved by the Control Officer, during three consecutive operating hours, the operator shall comply with the recordkeeping requirements in Section 501.3 of this rule. If this occurs more than 3 times in 3 months, the owner or operator shall notify the Control Officer in writing within 2 business days and the Control Officer shall require the owner or operator to submit a Corrective Action Plan (CAP). 306 307 REQUIREMENTS FOR AIR POLLUTION CONTROL EQUIPMENT ECS AND ECS MONITORING EQUIPMENT: If an ECS is operated during a performance test required by Section 503 of this rule, the owner or operator shall: 306.1 Emission Control System: For affected operations which may exceed any of the applicable standards set forth in Sections 300 of this rule, an owner or operator may comply by installing and operating an emission control system (ECS) or a combustion control system which reduces emissions to below the applicable standards in Section 300 of this rule. 306.2 307.1 Providing and Maintaining ECS Monitoring Devices: An owner or operator required to use an approved ECS pursuant to this rule shall not do so without first providing, properly installing, operating, and maintaining Properly install, operate, and maintain in calibration and in good working order, devices for indicating temperatures, pressures, transfer rates, rates of flow, or other operating conditions necessary to determine if air pollution control equipment is functioning properly and is properly maintained as described in an approved Operation and Maintenance (O&M) Plan. 306.3 O&M Plan Required for ECS: a. General Requirements: An owner or operator shall provide and maintain an O&M Plan for any ECS, any other emission processing equipment, and any ECS monitoring devices that are used pursuant to this rule or an air pollution permit. b. Approval by Control Officer: An owner or operator shall submit to the Control Officer for approval the O&M Plans of each ECS and each ECS monitoring device that is used pursuant to this rule. 33 c. Initial Plans: An owner or operator that is required to have an O&M Plan pursuant to this rule shall comply with all O&M Plans that the owner or operator has submitted for approval, but which have not yet been approved, unless notified by the Control Officer in writing. Once the initial plan has been approved in writing by the Control Officer, an owner or operator shall comply with this approved plan. d. Revisions to Plan: If revisions to the initial plan have been approved by the Control Officer in writing, an owner or operator shall comply with the revisions to the initial plan. If revisions to the plan have not yet been approved by the Control Officer in writing, then an owner or operator shall comply with the most recent O&M plan on file at Maricopa County Air Quality Department. e. Control Officer Modifications to Plan: After discussion with the owner or operator, the Control Officer may modify the plan in writing prior to approval of the initial O&M plan. An owner or operator shall then comply with the plan that has been modified by the Control Officer. 307.2 Submit to the Control Officer for approval an Operation and Maintenance (O&M) Plan for any ECS and any ECS monitoring devices that are used pursuant to this rule or to an air pollution permit. The O&M Plan shall include: a. ECS equipment manufacturer; and b. ECS equipment model; and c. ECS equipment identification number; and d. Operating parameters that will be monitored to demonstrate continued operation of the ECS in the manner the ECS was operated during the most recent performance test; and e. The manufacturer’s recommended maintenance procedures and frequencies or, if the manufacturer’s recommended maintenance procedures are not available, a maintenance plan based on good engineering practice to reduce emissions. 307.3 Provide and maintain readily available on-site at all times the O&M Plan(s) for any ECS and ECS monitoring devices that are used under this rule or an air pollution control permit. 307.4 Fully comply with all the identified actions and schedules provided in the most recent version of the O&M Plan submitted to the Control Officer, unless notified by the Control Officer in writing. 307.5 Submit a revised O&M Plan within 30 business days following receipt of the Control Officer's notice that an O&M Plan for any ECS, including any ECS monitoring device, is deficient or inadequate. 308 EMERGENCY FUEL USE NOTIFICATION: Each time a combustion unit is fired with emergency fuel, the owner or operator shall provide written notification to the Control Officer within 2 business days after combustion of emergency fuel begins. The written notification shall include a description of the emergency that necessitated the use of emergency fuel, the date that combustion of emergency fuel began, and the expected 34 duration of the emergency fuel usage. The written notification may be submitted by mail, email, fax, commercial delivery or hand delivery. SECTION 400 – ADMINISTRATIVE REQUIREMENTS 401 COMPLIANCE SCHEDULE FOR PERFORMANCE TESTING: The owner or operator of any combustion unit that becomes subject to the emission limits in Section 304.2 of this rule on or after [insert date of rule adoption] shall comply with following compliance schedules, as applicable, and the associated deadlines for demonstrating compliance. 401.1 Performance Test: The owner or operator shall demonstrate compliance with the applicable emission limits within 6 months after the combustion unit becomes subject to the emission limits in Section 304.2 of this rule. This requirement shall not apply to a combustion unit if modifications to an ECS or installation of an ECS is required to achieve compliance with the applicable emission limits and the owner or operator is in compliance with the applicable schedule in Section 401.3 or 401.4 of this rule. 401.1 401.2 O&M Plan: Any owner or operator employing an approved ECS on the effective date of this rule If different operating parameters or ECS maintenance procedures or schedules are used to achieve compliance with the emission limits in Section 304.2 of this rule, the owner or operator of the combustion unit shall by July 2, 2017 file an submit a revised O&M Plan with the Control Officer in accordance with Section 306.3 307 of this rule within 30 days after completion of the performance test required by Section 401.1 of this rule. 401.2 401.3 Modifications to Existing ECS: Any owner or operator required to modify their If it is necessary to modify an ECS equipment or system by either reconstructing or adding on equipment for compliance with this rule, an owner or operator shall by July 2, 2017 file a schedule for the modification with submit to the Control Officer a schedule for modification of the ECS within 6 months after the combustion unit becomes subject to the emission limits in Section 304.2 of this rule. The plan schedule shall show how the ECS is to be used to achieve full compliance and shall specify dates for completing increments of progress. Any and all ECS used to achieve such compliance shall be in operation by November 2, 2018. The owner or operator shall complete ECS modifications and demonstrate compliance with the applicable NOX emission limits within 12 months after the combustion unit becomes subject to the emission limits in Section 304.2 of this rule. 401.3 401.4 ECS Installation: An owner or operator required to install If installation of an ECS for is necessary to achieve compliance with numeric emission limits in this rule, an owner or operator shall by July 2, 2017 file a schedule for the installation with submit to the Control Officer a schedule for installation of the ECS within 6 months after the equipment becomes subject to the emission limits in Section 304.2 of this rule. The ECS shall then be installed and in compliance by November 2, 2019 The owner or operator shall complete the installation of an ECS and demonstrate compliance with the applicable NOX emission limits within 36 months after the combustion unit becomes subject to the emission limits in Section 304.2 of this rule. 35 402 COMPLIANCE SCHEDULE FOR RACT TUNING PROCEDURE: The owner or operator of any combustion unit that becomes subject to the requirements of Section 304.4 of this rule on or after [insert date of rule adoption] shall complete the RACT tuning procedure within 6 months after the combustion unit becomes subject to Section 304.4 of this rule. SECTION 500 – MONITORING AND RECORDS 501 RECORDKEEPING AND REPORTING: An owner or operator subject to this rule of a combustion unit shall comply with the requirements set forth in this section. Any records and data required by this section shall be kept on site at all times in a consistent and complete manner and be made available without delay to the Control Officer or his designee upon request. Records shall consist of the following information: 501.1 Equipment Listed in Section 102 of this Rule Combustion Units: Monthly records of type and amount Type of fuel used, amount of fuel used, and amount of the sulfur content of any liquid fuel or waste derived fuel gas combusted in the fuel if using liquid fuel, and the days and hours of operation. 501.2 Emergency Fuel Usage: Monthly records of type and amount of emergency fuel used, the sulfur content of the fuel, dates and hours of operation using emergency fuel, and nature of the emergency or purpose for the use of the emergency fuel as stated in Sections 104.1 and 104.2 and 104.3. Yearly records of the twelve month log of hours of operation in the emergency mode using emergency fuel. 501.3 Good Combustion Practice: Measurements of the temperature differential across the burners of turbines per Section 301.3 306 of this rule, results of evaluation and corrective action taken to reduce the temperature differential or a finding that the temperature differential returned to the range listed in Sections 301.3(a) 306.1 or 301.3(b) 306.2 of this rule without any action by the owner or operator. 501.4 Baseline Monitoring and Annual Tuning Procedure: Date that the procedure was performed on the particular combustion unit and at a minimum: stack gas temperature, flame conditions, nature of the adjustment and results of the nitrogen oxide and carbon monoxide concentrations obtained by using a handheld portable monitor after each adjustment. 501.5 RACT Tuning Procedure: Date the procedure was performed, the final control settings that reflect optimized combustion, the firing rate during the tuning procedure, a record of all adjustments and cleaning procedures, and a record of all operating parameters specified in Appendix A. 501.6 Operation & Maintenance Records: On each day an ECS operates, record the ECS operating parameters described in the O&M Plan. Record all maintenance actions taken within 24 hours of maintenance completion. An explanation shall be recorded for any scheduled maintenance that is not performed during the period designated in the O&M Plan. 501.7 Continuous Emission Monitoring Systems: All CEMS measurements, results of CEMS performance evaluations, CEMS calibration checks, and adjustments and maintenance performed on these systems. 36 502 RECORDS RETENTION: Copies of reports, logs and supporting documentation required by the Control Officer shall be retained for at least 5 years. Records and information required by this rule shall also be retained for at least 5 years. 503 COMPLIANCE DETERMINATION DEMONSTRATION: 503.1 Sulfur In Fuel Verification: a. Ultra Low Sulfur Oil: If the Control Officer requests documentation of the sulfur content of the fuel to demonstrate the 0.0015% limit, the owner or operator shall submit one of the following: (1) Fuel receipts, or (2) Contract specifications, or (3) Pipeline meter tickets, or (4) Fuel supplier information, or (5) Purchase records, or (6) Test results of the fuel for sulfur content Analytical results listing the sulfur content of the fuel, the test method conducted, and evidence that appropriate chain of custody procedures were followed. The items listed above must provide accurate sulfur content values or and be based on enforceable test methods as approved by the Administrator to determine the sulfur content. b. Waste Derived Fuel Gas: The owner or operator shall submit documentation of the concentration of the sulfur level content of the waste derived fuel gas to the Control Officer upon request. The sulfur content of gaseous fuels shall be determined by South Coast Air Quality Management District Method 307-91 Determination of Sulfur in a Gaseous Matrix. c. Purchase Documentation of Existing Low Sulfur Oil: The owner or operator shall maintain documentation of the purchase date of any low sulfur oil on site to demonstrate the oil was purchased prior to November 2, 2016. 503.2 Gaseous Emissions-Source Test Requirements: Boilers with a heat input capacity of 100 MMBtu per hour or greater, must conduct all applicable performance (stack) tests on a triennial basis. Triennial performance tests must be completed no more than 37 months after the previous performance test. The owner or operator of any combustion unit that is subject to numeric emission limits in Section 301, 304 and/or 305 of this rule shall conduct performance tests at least once every 5 years. The result of the performance test shall be the arithmetic mean of the results of three test runs. Each test run shall have a minimum sample time of one hour. In addition, the owner or operator shall comply with the following requirements: a. Nitrogen oxides shall be measured using EPA Reference Method 7 or 7E and carbon monoxide shall be measured using EPA Reference Method 10, as incorporated by reference in Section 504 of this rule. For stationary gas turbines, nitrogen oxides and carbon monoxide shall be measured dry and corrected to 37 15% oxygen. For all other combustion units, nitrogen oxides and carbon monoxide shall be measured dry and corrected to 3% oxygen. b. Particulate matter shall be measured using EPA Reference Method 5, or another EPA-approved test method designated by the Control Officer. A back-half analysis shall be performed using Reference Method 202 each time a performance test is required. c. The owner or operator may demonstrate compliance with applicable emission limits by conducting representative performance testing if all of the following requirements are satisfied: (1) All combustion units in the specified group were produced by the same manufacturer, have the same model number or other manufacturer’s designation in common, and have the same rated heat input capacity and operating specifications; (2) All combustion units in the specified group are operated and maintained in a similar manner; (3) At least one combustion unit or one-third of the combustion units in the specified group, whichever is greater, are tested each time a performance test is required; (4) Each time a performance test is required, different combustion units are tested so that all combustion units in the specified group are tested before any combustion units in the specified group are retested; and (5) If emissions from any combustion unit in the specified group exceed an applicable emission limit the owner or operator shall conduct a performance test on each unit in the specified group to demonstrate that each combustion unit in the specified group is in compliance with the applicable emission limit. 503.3 Gaseous Emissions-Continuous Emission Monitoring System (CEMS): Compliance with the emission requirements specified in Sections 301 through 304 305 of this rule may also be determined using CEMS. Where the combustion unit(s) are equipped with CEMS: a. General: All CEMS must be installed according to the procedures specified in 40 CFR 60.13(g). All CEMS shall be installed such that a representative measurement of emissions is obtained. Additional procedures for the location of CEMS found in 40 CFR 60, Appendix B shall be used. The data recorder for CEMS shall be in operation at all times the combustion unit is operated. b. Cycle Time: An owner or operator of any combustion unit using a CEMS shall ensure that the CEMS completes a minimum of one cycle of operation (sampling, analyzing, and data recording) for each successive 15-minute period. c. Calibration: Zero and span shall be checked once every 24 hours. The CEMS shall be calibrated in accordance with the manufacturer's specifications. d. Averaging: The data recorded during periods of calibration checks, zero and span adjustments shall not be included in averaging for compliance 38 determinations. Compliance shall be determined on an hourly basis using the average of the 3 three previous 1 1-hour average emissions concentrations. The 1-hour average emissions concentration shall be determined from at least two data points recorded by the CEMS. e. Accuracy Testing Quality Assurance: Accuracy testing of The owner or operator of the CEMS shall be conducted using a relative accuracy test audit pursuant to fully comply with 40 CFR 60, Appendix F. 504 COMPLIANCE DETERMINATION-TEST METHODS INCORPORATED BY REFERENCE: The following test methods are approved for use for the purpose of determining compliance with this rule. The test methods are incorporated by reference in Rule 360 and Appendix G of the Maricopa County Air Pollution Control Regulations. Alternative test methods as approved by the Administrator or other EPA-approved test methods may be used upon written approval from the Control Officer. When more than one test method is permitted for the same determination, an exceedance under any method will constitute a violation. Copies of test methods referenced in this section are available at the Maricopa County Air Quality Department. 504.1 EPA Reference Methods 1 (“Sample and Velocity Traverses for Stationary Sources”), and 1 A (“Sample and Velocity Traverses for Stationary Sources with Small Stacks and Ducts”) (40 CFR 60, Appendix A). 504.2 EPA Reference Methods 2 (“Determination of Stack Gas Velocity and Volumetric Flow Rate”), 2A (“Direct Measurement of Gas Volume through Pipes and Small Ducts”), 2C (“Determination of Stack Gas Velocity and Volumetric Flow Rate in Small Stacks or Ducts”), and 2D (“Measurement of Gas Volumetric Flow Rates in Small Pipes and Ducts”) (40 CFR 60, Appendix A). 504.3 EPA Reference Methods 3 (“Gas Analysis for the Determination of Dry Molecular Weight”), 3A (“Determination of Oxygen and Carbon Dioxide Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure)”), 3B (“Gas Analysis for the Determination of Emission Rate Correction Factor of or Excess Air”), and 3C (“Determination of Carbon Dioxide, Methane, Nitrogen and Oxygen from Stationary Sources”) (40 CFR 60, Appendix A). 504.4 EPA Reference Method 4 (“Determination of Moisture Content in Stack Gases”) (40 CFR 60, Appendix A). 504.5 EPA Reference Method 5 (“Determination of Particulate Emissions from Stationary Sources”) (40 CFR 60, Appendix A) 504.6 EPA Reference Method 202 (“Dry Impinger Method for Determination of Condensable Particulate Emissions from Stationary Sources”) (40 CFR 51, Appendix M). 504.7 EPA Reference Methods 7 (“Determination of Nitrogen Oxide Emissions from Stationary Sources”), 7A (“Determination of Nitrogen Oxide Emissions form Stationary Sources”), 7B (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Ultraviolet Spectrometry”), 7C (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Alkaline-Permanganate Colorimetric Method”), 7D (“Determination of Nitrogen Oxide Emissions from Stationary 39 Sources – Alkaline-Permanganate Chromatographic Method”), and 7E (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Instrumental Analyzer Method Procedure”), (40 CFR 60, Appendix A). 504.8 EPA Reference Method 9, (“Visual Determination of the Opacity of Emissions from Stationary Sources”) (40 CFR 60, Appendix A). 504.9 EPA Reference Method 10, (“Determination of Carbon Monoxide from Stationary Sources”) (40 CFR 60, Appendix A). 504.10 EPA Reference Method 20, (“Determination of Nitrogen Oxides, Sulfur Dioxide, and Diluent Emissions from Stationary Gas Turbines”) (40 CFR 60, Appendix A). 504.11 ASTM Method D2622-98 D2622-05, (“Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry”). 504.12 ASTM Method D2880-96 (“Standard Specification for Gas Turbine Fuel Oils”). 504.13 ASTM Method D4294-02 or D4294-03, (“Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy-Dispersive X-Ray Fluorescence Spectrometry”). 504.14 ASTM Method D5504-01 or D5504-08, (“Standard Test Method for Determination of Sulfur compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence”). 504.15 South Coast Air Quality Management District Method 307-94 307-91 (“Determination of Sulfur in a Gaseous Matrix”), revised 1994. 40 APPENDIX A TO RULE 323 RACT TUNING PROCEDURES Nothing in these equipment tuning procedures shall be construed to require any act or omission that would result in unsafe conditions or would be in violation of any regulation of requirement established by Factory Mutual, Industrial Risk Insurers, National Fire Prevention Association, the Industrial Commission of Arizona (Arizona Division of Occupational Safety and Health), the Federal Occupational Safety and Health Administration, or other relevant regulations and requirements. Steps in these procedures that are not applicable to specific combustion units may be omitted. Tuning Procedure for Forced Draft Fired Boilers, Steam Generating Units, and Process Heaters: 1. Operate the combustion unit at the firing rate most typical of normal operation. If the combustion unit experiences significant load variations during normal operation, operate it at its average firing rate. 2. At this firing rate, record the stack gas temperature, oxygen concentration, and CO concentration (for gaseous fuels) or smoke-spot number1 (for liquid fuels), and observe flame conditions after operation stabilizes at the firing rate selected. If the excess oxygen in the stack gas is at the lower end of the range of typical minimum values2, and if CO emissions are low and there is no smoke, the combustion unit is probably operating at near optimum efficiency at this particular firing rate. Complete the remaining steps in this procedure to determine whether still lower oxygen levels are practical. 3. Increase combustion air flow to the furnace until stack gas oxygen levels increase by one to two percent over the level measured in Step 2 and record the stack gas temperature, oxygen concentration, CO concentration (for gaseous fuels) or smoke-spot number (for liquid fuels), and observe flame conditions for these higher oxygen levels after boiler operation stabilizes. 4. Decrease combustion air flow until the stack gas oxygen concentration is at the level measured in Step 2. From this level, gradually reduce the combustion air flow, in small increments. After each increment, record the stack gas temperature, oxygen concentration, CO concentration (for gaseous fuels) and smoke-spot number (for liquid fuels). Also observe the flame and record any changes in its condition. 5. Continue to reduce combustion air flow stepwise, until one of these limits is reached: a. Unacceptable flame conditions, such as flame impingement on furnace walls or burner parts, excessive flame carryover, or flame instability; b. Stack gas CO concentrations greater than 400 ppm; c. Smoking at the stack; or 1 The smoke-spot number shall be determined with ASTM D2156. 2 Typical minimum oxygen levels for boilers firing at high firing rates are 0.5 – 3% (gaseous fuels) and 2 – 4% (liquid fuels). 41 d. Equipment related limitations, such as low windbox/furnace pressure differential, built in air-flow limits, etc. 6. Develop an O2/CO curve (for gaseous fuels) or O2/smoke curve (for liquid fuels) using the excess oxygen and CO or smoke-spot number data obtained at each combustion air flow setting. 7. From the O2/CO curve or the O2/smoke curve, find and record the stack gas oxygen levels where the CO emissions or smoke-spot number equal the following values: Fuel Measurement Value Gaseous CO Emissions 400 ppm #1 & #2 oils Smoke-spot number Number 1 #4 oils Smoke-spot number Number 2 #5 oils Smoke-spot number Number 3 Other oils Smoke-spot number Number 4 8. The stack gas oxygen level recorded in Step 7 is the minimum excess oxygen level (or the CO/smoke threshold). Compare the minimum excess oxygen level to the expected value provided by the combustion unit manufacturer. If the minimum level is found to be substantially higher than the value provided by the combustion unit manufacturer, burner adjustments can probably be made to improve fuel and air mixing, thereby allowing operation with less air. 9. Increase the minimum excess oxygen level identified in Step 7 by 0.5 to 2.0 percent and reset burner controls to operate automatically at this higher stack gas oxygen level. This margin above minimum oxygen level accounts for fuel variations, variations in atmospheric conditions, load changes, and nonrepeatability or play in automatic controls. 10. If the load of the combustion unit varies significantly during normal operation, repeat Steps 1 through 8 for firing rates that represent the upper and lower limits of the range of the load. Because control adjustments at one firing rate may affect conditions at other firing rates, it may not be possible to establish the optimum excess oxygen level at all firing rates. If this is the case, choose the burner control settings that give best performance over the range of firing rates. If one firing rate predominates, settings should optimize conditions at that firing rate. 11. Verify that the new settings can accommodate the sudden changes that may occur in daily operation without adverse effects. Do this by increasing and decreasing load rapidly while observing the flame and stack. If any of the conditions in Step 5 result, reset the combustion controls to provide a slightly higher level of excess oxygen. Verify the new settings in a similar manner. The final control settings that reflect combustion optimization shall be recorded for future reference. Natural Draft Fired Boilers, Steam Generating Units, and Process Heaters: 42 1. Verify that the combustion unit is operating at the lowest pressure or temperature setting that will satisfy load demand. This pressure or temperature will be used as a basis for comparative combustion analysis before and after tuning. 2. Verify that the combustion unit will operate for the minimum number of hours necessary to perform the tuning procedure. 3. Verify that the size of air supply openings is in compliance with applicable codes and regulations. Air supply openings must be fully open when the burner is firing and air flow must be unrestricted. 4. Verify that the vent is in good condition, properly sized, and free from obstruction. 5. Perform a combustion analysis at both high and low fire, if possible. Record the following data for each combustion analysis: a. The concentration of CO and oxygen; b. Inlet fuel pressure at burner at high and low firing rates; c. Steam pressure, water temperature, process fluid temperature, or temperature entering and leaving the combustion unit; and d. Inlet fuel use rate, if a meter is available. 6. Clean all dirty burners or burner orifices. Verify that fuel filters and moisture traps are in place, clean, and operating properly. Confirm proper location and orientation of burner diffuser spuds, gas canes, etc. Replace or repair damaged or missing burner parts. 7. Remove external and internal sediment and scale from heating surfaces. 8. Verify that the necessary water or process fluid treatment is being used. Confirm flushing and/or blowdown schedule. 9. Repair all leaks. In addition to the high-pressure lines, check the blow-off, drain, safety valve, bypass lines, and if used, the feed pump. 10. Perform the following safety checks: a. Test primary and secondary low water level controls; b. Check operating and limit pressure and temperature controls; c. Check pilot safety shut off operation; d. Check safety valve pressure setting and verify that the setting is consistent with load requirements; and e. Check limit safety control and spill switch. 11. Adjust the combustion unit to fire at the maximum inlet fuel use rate; record fuel manifold pressure. 43 12. Adjust draft and/or fuel pressure to obtain acceptable, clean combustion at high, medium, and low firing rates. The CO concentration should not exceed 400 ppm at 3% oxygen. 13. Verify that light-offs are smooth and safe. Perform a reduced fuel pressure test at both high and low firing rates in accordance with the manufacturer’s instructions. 14. Check and adjust the modulation controller. Verify proper, efficient, and clean combustion through the range of firing rates. When optimum performance has been achieved, record all data. 15. Perform a final combustion analysis on the warm combustion unit at high, medium, and low firing rates, if possible. Record data obtained from the combustion analysis as well as the following information: a. Inlet fuel pressure at burner at high and low firing rates; b. Pressure above draft hood or barometric damper at high, medium, and low firing rates. c. Steam pressure, water temperature, or process fluid pressure or temperature entering and leaving the combustion unit; and d. Inlet fuel use rate if a meter is available. 44 Return to list of attachments MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III – CONTROL OF AIR CONTAMINANTS RULE 323 FUEL BURNING EQUIPMENT FROM INDUSTRIAL/COMMERCIAL/INSTITUTIONAL (ICI) SOURCES INDEX SECTION 100 – GENERAL 101 PURPOSE 102 APPLICABILITY 103 EXEMPTIONS 104 PARTIAL EXEMPTIONS SECTION 200 – DEFINITIONS 201 ALTERNATIVE FUELS 202 ANNUAL HEAT INPUT 203 BOILER 204 COGENERATION STEAM GENERATING UNIT 205 COMBUSTION CONTROL SYSTEM 206 COMBUSTION UNIT 207 CONTINUOUS EMISSIONS MONITORING SYSTEM (CEMS) 208 CORRECTIVE ACTION PLAN (CAP) 209 EMERGENCY FUEL 210 EMISSION CONTROL SYSTEM (ECS) 211 FOSSIL FUEL 212 GAS TURBINE 213 HEAT INPUT 214 LOW SULFUR OIL 215 NATURAL GAS CURTAILMENT 216 OPACITY 217 OPERATING HOUR 218 PARTICULATE MATTER EMISSIONS 219 PARTS PER MILLION BY VOLUME DRY (PPMVD) 220 PEAK LOAD 45 221 PROCESS HEATER 222 RATED HEAT INPUT CAPACITY 223 STATIONARY GAS TURBINE 224 STEAM GENERATING UNIT 225 SULFUR OXIDES (SOX) 226 ULTRA LOW SULFUR OIL 227 UNCOMBINED WATER 228 WASTE DERIVED FUEL GAS 229 WATER HEATER SECTION 300 – STANDARDS 301 LIMITATIONS - PARTICULATE MATTER 302 LIMITATIONS - OPACITY 303 LIMITATIONS - SULFUR IN FUEL 304 LIMITATIONS - NITROGEN OXIDES 305 LIMITATIONS - CARBON MONOXIDE 306 GOOD COMBUSTION PRACTICES FOR STATIONARY GAS TURBINES 307 REQUIREMENTS FOR ECS AND ECS MONITORING EQUIPMENT 308 EMERGENCY FUEL USE NOTIFICATION SECTION 400 – ADMINISTRATIVE REQUIREMENTS 401 COMPLIANCE SCHEDULE FOR PERFORMANCE TESTING 402 COMPLIANCE SCHEDULE FOR RACT TUNING PROCEDURE SECTION 500 – MONITORING AND RECORDS 501 RECORDKEEPING AND REPORTING 502 RECORDS RETENTION 503 COMPLIANCE DEMONSTRATION 504 COMPLIANCE DETERMINATION-TEST METHODS INCORPORATED BY REFERENCE APPENDIX A TO RULE 323 46 Adopted 07/02/2003; Revised 10/17/2007; Revised 11/02/2016; Revised MM/DD/YYYY MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III-CONTROL OF AIR CONTAMINANTS RULE 323 FUEL BURNING EQUIPMENT FROM INDUSTRIAL/COMMERCIAL/INSTITUTIONAL (ICI) SOURCES SECTION 100 – GENERAL 101 PURPOSE: To limit the discharge of nitrogen oxides, sulfur oxides, carbon monoxide, and particulate matter emissions into the atmosphere from fuel burning combustion units at industrial and/or commercial and/or institutional (ICI) sources. 102 APPLICABILITY: This rule applies to the following types of combustion units that burn either fossil fuels or alternative fuels: 102.1 Each boiler or steam generating unit that has a maximum design rated heat input capacity greater than 10 million (MM) British thermal units per hour (Btu/hr). 102.2 Each stationary gas turbine with a heat input at peak load equal to or greater than 10 MMBtu/hr. 102.3 Each cogeneration steam generating unit with a heat input of greater than 10 MMBtu/hr. 102.4 Each indirect-fired process heater with a heat input greater than 10 MMBtu/hr. 102.5 NSPS & NESHAP: In addition to this rule, facilities may be subject to New Source Performance Standards (NSPS) in Rule 360 and/or National Emission Standards for Hazardous Air Pollutants (NESHAP) in Rule 370 of these rules. 103 EXEMPTIONS: This rule shall not apply to the following types of equipment: 103.1 Incinerators, crematories, or burn-off ovens; or 103.2 Dryers, cement and lime kilns; or 103.3 Direct-fired process heaters; or 103.4 Medical waste incinerators; or 103.5 Reciprocating internal combustion engines; or 103.6 Combustion equipment used in power plant operations for the purpose of supplying greater than one third of the electricity to any utility power distribution system for sale; or 103.7 Combustion equipment associated with nuclear power plant operations; or 103.8 Water heaters used for the sole purpose of heating water for comfort or for radiant heat; or 103.9 Municipal solid waste landfill enclosed combustors and non-enclosed flares. 47 104 PARTIAL EXEMPTIONS: 104.1 Stationary gas turbines listed in Section 102.2 of this rule that are used for any of the following reasons shall be exempt from Sections 301, 304, and 305, of this rule: a. Used for firefighting; or b. Used for flood control; or c. Engaged by manufacturers in research and the development of equipment for either gas turbine emission control techniques or gas turbine efficiency improvements. 104.2 All combustion units that are normally fired with natural gas shall be exempt from Sections 301, 304, 305, and 501.1 of this rule while firing emergency fuel during a natural gas curtailment or a natural gas emergency. For combustion units located at a major stationary source of nitrogen oxides, this exemption shall not exceed 168 hours per calendar year per combustion unit, excluding hours of operation for testing, reliability, training, and maintenance. 104.3 All combustion units that are normally fired with natural gas shall be exempt from Sections 301, 304, 305, and 501.1 of this rule while firing emergency fuel for the purposes of testing, reliability, training, and maintenance. This exemption shall not exceed 36 hours per calendar year per combustion unit, excluding hours of operation during natural gas curtailments and natural gas emergencies. SECTION 200 – DEFINITIONS: For the purpose of this rule, the following definitions shall apply, in addition to those definitions found in Rule 100 (General Provisions and Definitions) of these rules. In the event of any inconsistency between any of the Maricopa County air pollution control rules, the definitions in this rule take precedence. 201 ALTERNATIVE FUELS: Substitutes for traditional oil-derived and fossil-fuel derived motor vehicle fuels including but not limited to biodiesel, propane, ethanol, methanol, or waste derived fuel gas. 202 ANNUAL HEAT INPUT: The actual total heat input of fuels combusted in a unit during a calendar year, as calculated based on the amount of each fuel combusted and the higher heating value of each fuel. Annual heat input shall not include the heat input from emergency fuel combusted during natural gas curtailments and natural gas emergencies or emergency fuel combusted for purposes of testing, reliability, training, and maintenance as long as the usage limits in Sections 104.2 and 104.3 are not exceeded. 203 BOILER: A device that combusts any fossil fuel or alternative fuel and recovers thermal energy to heat water or another material. 204 COGENERATION STEAM GENERATING UNIT: Any device that is fired with fossil fuels or alternative fuels and simultaneously produces both useful thermal energy (such as heat or steam) and either electrical or mechanical energy from the same primary energy source. 205 COMBUSTION CONTROL SYSTEM: Equipment or technology, such as water injection or low-NOX burners, that reduce the formation of nitrogen oxides during combustion of fossil fuels or alternative fuels. 48 206 COMBUSTION UNIT: Any boiler, steam generating unit, stationary gas turbine, cogeneration steam generating unit, or indirect-fired process heater listed in Section 102 of this rule. 207 CONTINUOUS EMISSIONS MONITORING SYSTEM (CEMS): The total equipment required to sample, analyze, measure, and provide a permanent record of emissions by means of readings recorded at least once every 15 minutes (using an automated data acquisition and handling system (DAHS)). 208 CORRECTIVE ACTION PLAN (CAP): A methodical procedure that is used to evaluate and correct a turbine operational problem and that includes, at a minimum, improved preventative maintenance procedures, improved ECS operating practices, possible operational amendments, and progress reports. 209 EMERGENCY FUEL: Fuel fired only for purposes of testing, reliability, training, and maintenance or during circumstances such as a natural gas emergency or a natural gas curtailment, or breakdown of delivery system such as an unavoidable interruption of supply that makes it impossible to fire natural gas in the combustion unit. Fuel is not considered emergency fuel if it is used to avoid either peak demand charges or high gas prices during on-peak price periods or due to a voluntary reduction in natural gas usage. 210 EMISSION CONTROL SYSTEM (ECS): Post-combustion systems that are approved in writing by the Control Officer and are designed and operated in accordance with good engineering practice to reduce emissions from combustion equipment. A combustion control system is not an emission control system. 211 FOSSIL FUEL: Naturally occurring carbonaceous substances from the ground such as natural gas, petroleum, coal, and any form of solid, liquid or gaseous fuel derived from such material for the purpose of creating energy. 212 GAS TURBINE: A rotary engine driven by the expansion of hot gases that are generated by the combustion of fuel. 213 HEAT INPUT: Heat derived from the combustion of fuel not including the heat input from preheated combustion air, recirculated flue gases, or exhaust gases from other sources, such as gas turbines, internal combustion engines, and kilns. 214 LOW SULFUR OIL: Fuel oil containing less than or equal to 0.05% sulfur by weight. 215 NATURAL GAS CURTAILMENT: A shortage in the supply of natural gas, due solely to limitations or restrictions in distribution pipelines by the utility supplying the gas and not due to the cost of natural gas. 216 OPACITY: A condition of the ambient air, or any part thereof, in which an air contaminant partially or wholly obscures the view of an observer. 217 OPERATING HOUR: A clock hour during which a unit combusts fuel, either for part of the hour or for the entire hour. 218 PARTICULATE MATTER EMISSIONS: Any and all particulate matter emitted to the ambient air as measured by applicable state and federal test methods. 219 PARTS PER MILLION BY VOLUME DRY (PPMVD): A unit of proportion used to express concentration that is corrected to a dry basis. 49 220 PEAK LOAD: 100% of the manufacturer’s design capacity of a gas turbine at 288° Kelvin, 60% relative humidity, and 101.3 kilopascals pressure (ISO 3977 standard reference conditions and ratings). 221 PROCESS HEATER: An enclosed combustion device that uses controlled flame to transfer heat to a process fluid or a process material that is not a fluid or to heat transfer material for use in a process unit (not including the generation of steam). A process heater may be either indirect or direct-fired, dependent upon whether the gases of combustion mix with and exhaust to the same stack or vent (direct-fired) with gases emanating from the process material or not (indirect-fired). Emissions from indirect-fired units consist entirely of products of combustion while emissions from direct-fired units are unique to the given process and may vary widely in any industrial process. A process heater is not an oven or kiln used for drying, curing, baking, cooking, calcining, or vitrifying. 222 RATED HEAT INPUT CAPACITY: The heat input capacity as specified on the nameplate of the combustion unit. If the combustion unit has been altered or modified so that its maximum heat input is different than the heat input capacity on the nameplate (design heat capacity), the maximum heat input shall be considered as the rated heat input capacity. 223 STATIONARY GAS TURBINE: Any gas turbine that is not self-propelled or that is attached to a foundation. 224 STEAM GENERATING UNIT: A device that combusts any fossil fuel or alternative fuel and produces steam or heats water or heats any heat transfer medium. 225 SULFUR OXIDES (SOX): The sum of the oxides of sulfur emitted from the flue gas from a combustion unit that are directly dependent upon the amount of sulfur in the fuel used. 226 ULTRA LOW SULFUR OIL: Fuel oil containing less than or equal to 0.0015 % sulfur by weight. 227 UNCOMBINED WATER: Condensed water containing no more than analytical trace amounts of other chemical elements or compounds. 228 WASTE DERIVED FUEL GAS: A gaseous fuel that is generated from the biodegradation of solid or liquid waste including, but not limited to, digester gas and landfill gas. 229 WATER HEATER: A closed vessel in which water is heated by combustion of fuel and water is either withdrawn for use external to the vessel (at pressures not exceeding 160 psi with all controls and devices preventing water temperatures from exceeding 210°F) or used for radiant heat. Water heaters are usually no larger than 1 MM Btu/hr and do not reach temperatures of 220°F and higher. SECTION 300 – STANDARDS 301 LIMITATIONS – PARTICULATE MATTER: An owner or operator of any combustion unit with either a rated heat input capacity or heat input greater than 100 MMBtu/hr shall not discharge, cause, or allow the discharge of particulate matter emissions, caused by combustion of non-gaseous liquid fuels or a blend of liquid fuels with other fuels, in excess of 0.10 pounds/MMBtu. 50 302 LIMITATIONS – OPACITY: An owner or operator shall not discharge into the ambient air from any single source of emissions any air contaminant, other than uncombined water, in excess of 20% opacity. 303 LIMITATIONS – SULFUR IN FUEL: An owner or operator of any combustion unit that burns fuel oil or a mixture or blend of fuel oil with any other fuels shall use only ultra low sulfur oil. An existing supply of low sulfur oil purchased or obtained prior to November 2, 2016 may be used until depleted. An owner or operator of any combustion unit that burns waste derived fuel gas shall use only waste derived fuel gas that contains no more than 0.08% sulfur by weight, alone or in combination with other fuels. 304 LIMITATIONS – NITROGEN OXIDES: An owner or operator of any combustion unit shall comply with the subsections specified in Table 323-1. TABLE 323-1 FOR COMBUSTION UNITS THAT ARE NOT THE OWNER OR LOCATED AT A MAJOR SOURCE OF OPERATOR SHALL NITROGEN OXIDES: COMPLY WITH: Stationary gas turbines 304.1 and 304.2 Combustion units (>100 MMBtu/hr) except stationary gas 304.3 turbines Combustion units (≤ 100 MMBtu/hr) except stationary gas 304.1 or 304.2 or 304.4* turbines FOR COMBUSTION UNITS THAT ARE THE OWNER OR LOCATED AT A MAJOR SOURCE OF OPERATOR SHALL NITROGEN OXIDES: COMPLY WITH: Stationary gas turbines 304.1 and 304.2 Combustion units (> 100 MMBtu/hour) except stationary 304.3 gas turbines Combustion units (> 50 MMBtu/hour and ≤ 100 304.2 MMBtu/hour) except stationary gas turbines Combustion units (> 10 MMBtu/hour and ≤ 50 304.2 or 304.4* MMBtu/hour with annual heat input ≥ 220,000 therms) except stationary gas turbines Combustion units (> 10 MMBtu/hour and ≤ 50 304.1 or 304.2 or 304.4* MMBtu/hour with annual heat input < 220,000 therms) except stationary gas turbines * The RACT tuning procedures in Section 304.4 are not appropriate for combustion units equipped with Low- NOX burners or burners utilizing a premix flame. 304.1 Baseline Monitoring and Annual Tuning: a. Establish and record the initial optimal baseline concentrations for NOX and CO within 90 days of the first usage of the combustion unit utilizing the initial design burner specifications or manufacturer’s recommendations to ensure good combustion practices. The initial design burner specifications or manufacturer’s recommendations shall be kept onsite and available to the Control Office upon request. b. Tune the combustion unit annually in accordance with the manufacturer’s recommended procedure. The manufacturer’s recommended procedures shall be 51 kept onsite and available to the Control Officer upon request. For low emission burner systems that do not provide accessibility for combustion chamber inspection, burner inspection, or inspection of the flame pattern, an owner or operator shall provide documentation from the manufacturer and follow the manufacturer’s recommended procedure. If the manufacturer’s recommended tuning procedure is not available, the owner or operator shall tune the combustion unit annually by following, at a minimum, the steps listed in 304.1b.(1) – (5), if the combustion unit is so equipped, and if such procedures are appropriate to the type of combustion unit: (1) Inspect the burner system and clean and replace any components of the burner as necessary to minimize emissions of NOX and CO; and (2) Inspect the burner chamber for areas of impingement and remove if necessary; and (3) Inspect the flame pattern and make adjustments as necessary to optimize the flame pattern; and (4) Inspect the system controlling the air-to-fuel ratio and ensure that it is correctly calibrated and functioning properly; and (5) Using a portable monitor, measure the NOX and CO concentration of the effluent stream after each adjustment is made to ensure optimal baseline concentrations are maintained. 304.2 RACT Emission Limits: Limit nitrogen oxide emissions to no more than the following amounts: a. Stationary Gas Turbines: (1) 42 ppmvd corrected to 15% oxygen calculated as nitrogen dioxide, when burning gaseous fuel. (2) 65 ppmvd corrected to 15% oxygen calculated as nitrogen dioxide, when burning liquid fuel. b. All Combustion Units Except Stationary Gas Turbines: (1) 30 ppmvd corrected to 3% oxygen calculated as nitrogen dioxide, when burning gaseous fuel. (2) 40 ppmvd corrected to 3% oxygen calculated as nitrogen dioxide, when burning liquid fuel. 304.3 Semi-Annual Tuning and RACT Emission Limits: a. Tune the combustion unit every 6 months in accordance with the manufacturer’s recommended procedure or in accordance with the procedures listed in Section 304.1.b(1) through (5) of this rule and; b. Meet the RACT emission limits as stated in Section 304.2 of this rule. 304.4 RACT Tuning Procedures: Tune the combustion unit every 12 months using the procedure in Appendix A of this rule that is appropriate for the combustion unit. 52 305 LIMITATIONS-CARBON MONOXIDE: An owner or operator of any combustion unit with a heat input greater than 100 MMBtu/hr shall not cause to be discharged into the atmosphere, carbon monoxide (CO), measured in excess of 400 ppmvd corrected to 15% oxygen for Stationary Gas Turbines, and corrected to 3% oxygen for all Combustion Units Except Stationary Gas Turbines. 306 GOOD COMBUSTION PRACTICES FOR STATIONARY GAS TURBINES: The owner or operator of any stationary gas turbine listed in Section 102.2 of this rule shall, regardless of fuel type, use operational practices recommended by the manufacturer to ensure good combustion control. The owner or operator of any stationary gas turbine listed in Section 102.2 of this rule shall demonstrate good combustion control using the parametric monitoring method listed below, or by operating a continuous emissions monitoring system to demonstrate compliance with the limits in Sections 304 and 305 of this rule, as applicable. 306.1 Monitor the maximum temperature differential across the combustion burners or at locations around the back end of the turbine, dependent upon the particular unit, to ensure no more than a 100F difference using a thermocouple. Differential temperatures shall be measured and recorded at least once during every operating hour. If a temperature differential of greater than 100F is observed across the burners, investigation and corrective action shall be taken within three hours to reduce the temperature difference to 100F or less. 306.2 If the manufacturer recommends that the maximum numerical temperature differential to ensure good combustion is greater than 100°F, then proof of this maximum alternate temperature differential shall be submitted to the Control Officer. The procedure to measure the maximum temperature differential listed in Section 306.1 of this rule shall then be followed using this alternate recommended maximum temperature differential after approval by the Control Officer. 306.3 If the differential temperature exceeds 100°F, or the alternate temperature differential recommended by the manufacturer and approved by the Control Officer, during three consecutive operating hours, the operator shall comply with the recordkeeping requirements in Section 501.3 of this rule. If this occurs more than 3 times in 3 months, the owner or operator shall notify the Control Officer in writing within 2 business days and the Control Officer shall require the owner or operator to submit a Corrective Action Plan (CAP). 307 REQUIREMENTS FOR ECS AND ECS MONITORING EQUIPMENT: If an ECS is operated during a performance test required by Section 503 of this rule, the owner or operator shall: 307.1 Properly install, operate, and maintain in calibration and in good working order, devices for indicating temperatures, pressures, transfer rates, rates of flow, or other operating conditions necessary to determine if air pollution control equipment is functioning properly and is properly maintained. 307.2 Submit to the Control Officer for approval an Operation and Maintenance (O&M) Plan for any ECS and any ECS monitoring devices that are used pursuant to this rule or to an air pollution permit. The O&M Plan shall include: 53 a. ECS equipment manufacturer; and b. ECS equipment model; and c. ECS equipment identification number; and d. Operating parameters that will be monitored to demonstrate continued operation of the ECS in the manner the ECS was operated during the most recent performance test; and e. The manufacturer’s recommended maintenance procedures and frequencies or, if the manufacturer’s recommended maintenance procedures are not available, a maintenance plan based on good engineering practice to reduce emissions. 307.3 Provide and maintain readily available on-site at all times the O&M Plan(s) for any ECS and ECS monitoring devices that are used under this rule or an air pollution control permit. 307.4 Fully comply with all the identified actions and schedules provided in the most recent version of the O&M Plan submitted to the Control Officer, unless notified by the Control Officer in writing. 307.5 Submit a revised O&M Plan within 30 business days following receipt of the Control Officer's notice that an O&M Plan for any ECS, including any ECS monitoring device, is deficient or inadequate. 308 EMERGENCY FUEL USE NOTIFICATION: Each time a combustion unit is fired with emergency fuel, the owner or operator shall provide written notification to the Control Officer within 2 business days after combustion of emergency fuel begins. The written notification shall include a description of the emergency that necessitated the use of emergency fuel, the date that combustion of emergency fuel began, and the expected duration of the emergency fuel usage. The written notification may be submitted by mail, email, fax, commercial delivery or hand delivery. SECTION 400 – ADMINISTRATIVE REQUIREMENTS 401 COMPLIANCE SCHEDULE FOR PERFORMANCE TESTING: The owner or operator of any combustion unit that becomes subject to the emission limits in Section 304.2 of this rule on or after [insert date of rule adoption] shall comply with following compliance schedules, as applicable, and the associated deadlines for demonstrating compliance. 401.1 Performance Test: The owner or operator shall demonstrate compliance with the applicable emission limits within 6 months after the combustion unit becomes subject to the emission limits in Section 304.2 of this rule. This requirement shall not apply to a combustion unit if modifications to an ECS or installation of an ECS is required to achieve compliance with the applicable emission limits and the owner or operator is in compliance with the applicable schedule in Section 401.3 or 401.4 of this rule. 401.2 O&M Plan: If different operating parameters or ECS maintenance procedures or schedules are used to achieve compliance with the emission limits in Section 304.2 of this rule, the owner or operator of the combustion unit shall submit a revised O&M 54 Plan in accordance with Section 307 of this rule within 30 days after completion of the performance test required by Section 401.1 of this rule. 401.3 Modifications to Existing ECS: If it is necessary to modify an ECS by either reconstructing or adding on equipment , an owner or operator shall submit to the Control Officer a schedule for modification of the ECS within 6 months after the combustion unit becomes subject to the emission limits in Section 304.2 of this rule. The schedule shall show how the ECS is to be used to achieve full compliance and shall specify dates for completing increments of progress. The owner or operator shall complete ECS modifications and demonstrate compliance with the applicable NOX emission limits within 12 months after the combustion unit becomes subject to the emission limits in Section 304.2 of this rule. 401.4 ECS Installation: If installation of an ECS is necessary to achieve compliance with numeric emission limits in this rule, an owner or operator shall submit to the Control Officer a schedule for installation of the ECS within 6 months after the equipment becomes subject to the emission limits in Section 304.2 of this rule. The owner or operator shall complete the installation of an ECS and demonstrate compliance with the applicable NOX emission limits within 36 months after the combustion unit becomes subject to the emission limits in Section 304.2 of this rule. 402 COMPLIANCE SCHEDULE FOR RACT TUNING PROCEDURE: The owner or operator of any combustion unit that becomes subject to the requirements of Section 304.4 of this rule on or after [insert date of rule adoption] shall complete the RACT tuning procedure within 6 months after the combustion unit becomes subject to Section 304.4 of this rule. SECTION 500 – MONITORING AND RECORDS 501 RECORDKEEPING AND REPORTING: An owner or operator of a combustion unit shall comply with the requirements set forth in this section. Any records and data required by this section shall be kept on site at all times in a consistent and complete manner and be made available without delay to the Control Officer or his designee upon request. Records shall consist of the following information: 501.1 Combustion Units: Monthly records of type and amount of fuel used, and the sulfur content of any liquid fuel or waste derived fuel gas combusted. 501.2 Emergency Fuel Usage: Monthly records of type and amount of emergency fuel used, the sulfur content of the fuel, dates and hours of operation using emergency fuel, and nature of the emergency or purpose for the use of the emergency fuel as stated in Sections 104.2 and 104.3. Yearly records of the twelve month log of hours of operation using emergency fuel. 501.3 Good Combustion Practice: Measurements of the temperature differential across the burners of turbines per Section 306 of this rule, results of evaluation and corrective action taken to reduce the temperature differential or a finding that the temperature differential returned to the range listed in Sections 306.1 or 306.2 of this rule without any action by the owner or operator. 501.4 Baseline Monitoring and Annual Tuning Procedure: Date that the procedure was performed on the particular combustion unit and at a minimum: stack gas 55 temperature, flame conditions, nature of the adjustment and results of the nitrogen oxide and carbon monoxide concentrations obtained by using a portable monitor after each adjustment. 501.5 RACT Tuning Procedure: Date the procedure was performed, the final control settings that reflect optimized combustion, the firing rate during the tuning procedure, a record of all adjustments and cleaning procedures, and a record of all operating parameters specified in Appendix A. 501.6 Operation & Maintenance Records: On each day an ECS operates, record the ECS operating parameters described in the O&M Plan. Record all maintenance actions taken within 24 hours of maintenance completion. An explanation shall be recorded for any scheduled maintenance that is not performed during the period designated in the O&M Plan. 501.7 Continuous Emission Monitoring Systems: All CEMS measurements, results of CEMS performance evaluations, CEMS calibration checks, and adjustments and maintenance performed on these systems. 502 RECORDS RETENTION: Copies of reports, logs and supporting documentation required by the Control Officer shall be retained for at least 5 years. Records and information required by this rule shall also be retained for at least 5 years. 503 COMPLIANCE DEMONSTRATION: 503.1 Sulfur Verification: a. Ultra Low Sulfur Oil: If the Control Officer requests documentation of the sulfur content of the fuel to demonstrate the 0.0015% limit, the owner or operator shall submit one of the following: (1) Fuel receipts, or (2) Contract specifications, or (3) Pipeline meter tickets, or (4) Fuel supplier information, or (5) Purchase records, or (6) Analytical results listing the sulfur content of the fuel, the test method conducted, and evidence that appropriate chain of custody procedures were followed. The items listed above must provide accurate sulfur content values and be based on enforceable test methods as approved by the Administrator to determine the sulfur content. b. Waste Derived Fuel Gas: The owner or operator shall submit documentation of the sulfur content of the waste derived fuel gas to the Control Officer upon request. The sulfur content of gaseous fuels shall be determined by South Coast Air Quality Management District Method 307-91 Determination of Sulfur in a Gaseous Matrix. 56 c. Purchase Documentation of Existing Low Sulfur Oil: The owner or operator shall maintain documentation of the purchase date of any low sulfur oil on site to demonstrate the oil was purchased prior to November 2, 2016. 503.2 Source Test Requirements: The owner or operator of any combustion unit that is subject to numeric emission limits in Section 301, 304 and/or 305 of this rule shall conduct performance tests at least once every 5 years. The result of the performance test shall be the arithmetic mean of the results of three test runs. Each test run shall have a minimum sample time of one hour. In addition, the owner or operator shall comply with the following requirements: a. Nitrogen oxides shall be measured using EPA Reference Method 7 or 7E and carbon monoxide shall be measured using EPA Reference Method 10, as incorporated by reference in Section 504 of this rule. For stationary gas turbines, nitrogen oxides and carbon monoxide shall be measured dry and corrected to 15% oxygen. For all other combustion units, nitrogen oxides and carbon monoxide shall be measured dry and corrected to 3% oxygen. b. Particulate matter shall be measured using EPA Reference Method 5, or another EPA-approved test method designated by the Control Officer. A back-half analysis shall be performed using Reference Method 202 each time a performance test is required. c. The owner or operator may demonstrate compliance with applicable emission limits by conducting representative performance testing if all of the following requirements are satisfied: (1) All combustion units in the specified group were produced by the same manufacturer, have the same model number or other manufacturer’s designation in common, and have the same rated heat input capacity and operating specifications; (2) All combustion units in the specified group are operated and maintained in a similar manner; (3) At least one combustion unit or one-third of the combustion units in the specified group, whichever is greater, are tested each time a performance test is required; (4) Each time a performance test is required, different combustion units are tested so that all combustion units in the specified group are tested before any combustion units in the specified group are retested; and (5) If emissions from any combustion unit in the specified group exceed an applicable emission limit the owner or operator shall conduct a performance test on each unit in the specified group to demonstrate that each combustion unit in the specified group is in compliance with the applicable emission limit. 503.3 Gaseous Emissions-Continuous Emission Monitoring System (CEMS): Compliance with the emission requirements specified in Sections 301 through 305 of this rule may also be determined using CEMS. Where the combustion unit(s) are equipped with CEMS: 57 a. General: All CEMS must be installed according to the procedures specified in 40 CFR 60.13(g). All CEMS shall be installed such that a representative measurement of emissions is obtained. Additional procedures for the location of CEMS found in 40 CFR 60, Appendix B shall be used. The data recorder for CEMS shall be in operation at all times the combustion unit is operated. b. Cycle Time: An owner or operator of any combustion unit using a CEMS shall ensure that the CEMS completes a minimum of one cycle of operation (sampling, analyzing, and data recording) for each successive 15-minute period. c. Calibration: Zero and span shall be checked once every 24 hours. The CEMS shall be calibrated in accordance with the manufacturer's specifications. d. Averaging: The data recorded during periods of calibration checks, zero and span adjustments shall not be included in averaging for compliance determinations. Compliance shall be determined on an hourly basis using the average of the three previous 1-hour average emissions concentrations. The 1- hour average emissions concentration shall be determined from at least two data points recorded by the CEMS. e. Quality Assurance: The owner or operator of the CEMS shall fully comply with 40 CFR 60, Appendix F. 504 COMPLIANCE DETERMINATION-TEST METHODS INCORPORATED BY REFERENCE: The following test methods are approved for use for the purpose of determining compliance with this rule. The test methods are incorporated by reference in Rule 360 and Appendix G of the Maricopa County Air Pollution Control Regulations. Alternative test methods as approved by the Administrator or other EPA-approved test methods may be used upon written approval from the Control Officer. When more than one test method is permitted for the same determination, an exceedance under any method will constitute a violation. Copies of test methods referenced in this section are available at the Maricopa County Air Quality Department. 504.1 EPA Reference Methods 1 (“Sample and Velocity Traverses for Stationary Sources”), and 1 A (“Sample and Velocity Traverses for Stationary Sources with Small Stacks and Ducts”) (40 CFR 60, Appendix A). 504.2 EPA Reference Methods 2 (“Determination of Stack Gas Velocity and Volumetric Flow Rate”), 2A (“Direct Measurement of Gas Volume through Pipes and Small Ducts”), 2C (“Determination of Stack Gas Velocity and Volumetric Flow Rate in Small Stacks or Ducts”), and 2D (“Measurement of Gas Volumetric Flow Rates in Small Pipes and Ducts”) (40 CFR 60, Appendix A). 504.3 EPA Reference Methods 3 (“Gas Analysis for the Determination of Dry Molecular Weight”), 3A (“Determination of Oxygen and Carbon Dioxide Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure)”), 3B (“Gas Analysis for the Determination of Emission Rate Correction Factor or Excess Air”), and 3C (“Determination of Carbon Dioxide, Methane, Nitrogen and Oxygen from Stationary Sources”) (40 CFR 60, Appendix A). 504.4 EPA Reference Method 4 (“Determination of Moisture Content in Stack Gases”) (40 CFR 60, Appendix A). 58 504.5 EPA Reference Method 5 (“Determination of Particulate Emissions from Stationary Sources”) (40 CFR 60, Appendix A) 504.6 EPA Reference Method 202 (“Dry Impinger Method for Determination of Condensable Particulate Emissions from Stationary Sources”) (40 CFR 51, Appendix M). 504.7 EPA Reference Methods 7 (“Determination of Nitrogen Oxide Emissions from Stationary Sources”) and 7E (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Instrumental Analyzer Procedure”), (40 CFR 60, Appendix A). 504.8 EPA Reference Method 9, (“Visual Determination of the Opacity of Emissions from Stationary Sources”) (40 CFR 60, Appendix A). 504.9 EPA Reference Method 10, (“Determination of Carbon Monoxide from Stationary Sources”) (40 CFR 60, Appendix A). 504.10 EPA Reference Method 20, (“Determination of Nitrogen Oxides, Sulfur Dioxide, and Diluent Emissions from Stationary Gas Turbines”) (40 CFR 60, Appendix A). 504.11 ASTM Method D2622-05, (“Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry”). 504.12 ASTM Method D2880-96 (“Standard Specification for Gas Turbine Fuel Oils”). 504.13 ASTM Method D4294-02 or D4294-03, (“Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy-Dispersive X-Ray Fluorescence Spectrometry”). 504.14 ASTM Method D5504-01 or D5504-08, (“Standard Test Method for Determination of Sulfur compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence”). 504.15 South Coast Air Quality Management District Method 307-91 (“Determination of Sulfur in a Gaseous Matrix”), revised 1994. 59 APPENDIX A TO RULE 323 RACT TUNING PROCEDURES Nothing in these equipment tuning procedures shall be construed to require any act or omission that would result in unsafe conditions or would be in violation of any regulation of requirement established by Factory Mutual, Industrial Risk Insurers, National Fire Prevention Association, the Industrial Commission of Arizona (Arizona Division of Occupational Safety and Health), the Federal Occupational Safety and Health Administration, or other relevant regulations and requirements. Steps in these procedures that are not applicable to specific combustion units may be omitted. Tuning Procedure for Forced Draft Fired Boilers, Steam Generating Units, and Process Heaters: 1. Operate the combustion unit at the firing rate most typical of normal operation. If the combustion unit experiences significant load variations during normal operation, operate it at its average firing rate. 2. At this firing rate, record the stack gas temperature, oxygen concentration, and CO concentration (for gaseous fuels) or smoke-spot number3 (for liquid fuels), and observe flame conditions after operation stabilizes at the firing rate selected. If the excess oxygen in the stack gas is at the lower end of the range of typical minimum values4, and if CO emissions are low and there is no smoke, the combustion unit is probably operating at near optimum efficiency at this particular firing rate. Complete the remaining steps in this procedure to determine whether still lower oxygen levels are practical. 3. Increase combustion air flow to the furnace until stack gas oxygen levels increase by one to two percent over the level measured in Step 2 and record the stack gas temperature, oxygen concentration, CO concentration (for gaseous fuels) or smoke-spot number (for liquid fuels), and observe flame conditions for these higher oxygen levels after boiler operation stabilizes. 4. Decrease combustion air flow until the stack gas oxygen concentration is at the level measured in Step 2. From this level, gradually reduce the combustion air flow, in small increments. After each increment, record the stack gas temperature, oxygen concentration, CO concentration (for gaseous fuels) and smoke-spot number (for liquid fuels). Also observe the flame and record any changes in its condition. 5. Continue to reduce combustion air flow stepwise, until one of these limits is reached: a. Unacceptable flame conditions, such as flame impingement on furnace walls or burner parts, excessive flame carryover, or flame instability; b. Stack gas CO concentrations greater than 400 ppm; c. Smoking at the stack; or 3 The smoke-spot number shall be determined with ASTM D2156. 4 Typical minimum oxygen levels for boilers firing at high firing rates are 0.5 – 3% (gaseous fuels) and 2 – 4% (liquid fuels). 60 d. Equipment related limitations, such as low windbox/furnace pressure differential, built in air-flow limits, etc. 6. Develop an O2/CO curve (for gaseous fuels) or O2/smoke curve (for liquid fuels) using the excess oxygen and CO or smoke-spot number data obtained at each combustion air flow setting. 7. From the O2/CO curve or the O2/smoke curve, find and record the stack gas oxygen levels where the CO emissions or smoke-spot number equal the following values: Fuel Measurement Value Gaseous CO Emissions 400 ppm #1 & #2 oils Smoke-spot number Number 1 #4 oils Smoke-spot number Number 2 #5 oils Smoke-spot number Number 3 Other oils Smoke-spot number Number 4 8. The stack gas oxygen level recorded in Step 7 is the minimum excess oxygen level (or the CO/smoke threshold). Compare the minimum excess oxygen level to the expected value provided by the combustion unit manufacturer. If the minimum level is found to be substantially higher than the value provided by the combustion unit manufacturer, burner adjustments can probably be made to improve fuel and air mixing, thereby allowing operation with less air. 9. Increase the minimum excess oxygen level identified in Step 7 by 0.5 to 2.0 percent and reset burner controls to operate automatically at this higher stack gas oxygen level. This margin above minimum oxygen level accounts for fuel variations, variations in atmospheric conditions, load changes, and nonrepeatability or play in automatic controls. 10. If the load of the combustion unit varies significantly during normal operation, repeat Steps 1 through 8 for firing rates that represent the upper and lower limits of the range of the load. Because control adjustments at one firing rate may affect conditions at other firing rates, it may not be possible to establish the optimum excess oxygen level at all firing rates. If this is the case, choose the burner control settings that give best performance over the range of firing rates. If one firing rate predominates, settings should optimize conditions at that firing rate. 11. Verify that the new settings can accommodate the sudden changes that may occur in daily operation without adverse effects. Do this by increasing and decreasing load rapidly while observing the flame and stack. If any of the conditions in Step 5 result, reset the combustion controls to provide a slightly higher level of excess oxygen. Verify the new settings in a similar manner. The final control settings that reflect combustion optimization shall be recorded for future reference. Natural Draft Fired Boilers, Steam Generating Units, and Process Heaters: 1. Verify that the combustion unit is operating at the lowest pressure or temperature setting that will satisfy load demand. This pressure or temperature will be used as a basis for comparative combustion analysis before and after tuning. 61 2. Verify that the combustion unit will operate for the minimum number of hours necessary to perform the tuning procedure. 3. Verify that the size of air supply openings is in compliance with applicable codes and regulations. Air supply openings must be fully open when the burner is firing and air flow must be unrestricted. 4. Verify that the vent is in good condition, properly sized, and free from obstruction. 5. Perform a combustion analysis at both high and low fire, if possible. Record the following data for each combustion analysis: a. The concentration of CO and oxygen; b. Inlet fuel pressure at burner at high and low firing rates; c. Steam pressure, water temperature, process fluid temperature, or temperature entering and leaving the combustion unit; and d. Inlet fuel use rate, if a meter is available. 6. Clean all dirty burners or burner orifices. Verify that fuel filters and moisture traps are in place, clean, and operating properly. Confirm proper location and orientation of burner diffuser spuds, gas canes, etc. Replace or repair damaged or missing burner parts. 7. Remove external and internal sediment and scale from heating surfaces. 8. Verify that the necessary water or process fluid treatment is being used. Confirm flushing and/or blowdown schedule. 9. Repair all leaks. In addition to the high-pressure lines, check the blow-off, drain, safety valve, bypass lines, and if used, the feed pump. 10. Perform the following safety checks: a. Test primary and secondary low water level controls; b. Check operating and limit pressure and temperature controls; c. Check pilot safety shut off operation; d. Check safety valve pressure setting and verify that the setting is consistent with load requirements; and e. Check limit safety control and spill switch. 11. Adjust the combustion unit to fire at the maximum inlet fuel use rate; record fuel manifold pressure. 12. Adjust draft and/or fuel pressure to obtain acceptable, clean combustion at high, medium, and low firing rates. The CO concentration should not exceed 400 ppm at 3% oxygen. 13. Verify that light-offs are smooth and safe. Perform a reduced fuel pressure test at both high and low firing rates in accordance with the manufacturer’s instructions. 62 14. Check and adjust the modulation controller. Verify proper, efficient, and clean combustion through the range of firing rates. When optimum performance has been achieved, record all data. 15. Perform a final combustion analysis on the warm combustion unit at high, medium, and low firing rates, if possible. Record data obtained from the combustion analysis as well as the following information: a. Inlet fuel pressure at burner at high and low firing rates; b. Pressure above draft hood or barometric damper at high, medium, and low firing rates. c. Steam pressure, water temperature, or process fluid pressure or temperature entering and leaving the combustion unit; and d. Inlet fuel use rate if a meter is available. 63 Return to list of attachments DRAFT NOTICE OF FINAL RULEMAKING MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III – CONTROL OF AIR CONTAMINANTS RULE 324: STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINES (RICE) The Maricopa County Air Quality Department (MCAQD) is proposing to amend Rule 324 (Stationary Reciprocating Internal Combustion Engines (RICE)). The Control Officer is posting this Draft Notice of Final Rulemaking on the Maricopa County Enhanced Regulatory Outreach Program (EROP) website as part of the Report to the Board of Supervisors, in accordance with the Maricopa County EROP Policy. This notice includes the preamble, as prescribed in A.R.S. § 49-471.05, and the full text of the rule, including the intended actions to make new sections or amend, repeal, or renumber the sections of the rule. This notice also includes a list of all previous notices posted on the Maricopa County EROP website addressing the proposed rule and the concise explanatory statement prescribed in A.R.S. § 49-471.07, subsection B. PREAMBLE 1. Statutory authority for the rulemaking: A.R.S. §§ 49-112, 49-474, 49-479 and 49-480 2. Name and address of department personnel with whom persons may communicate regarding the rulemaking: Name: Scott Kahldon or Kimberly Butler Maricopa County Air Quality Department Planning and Analysis Division Address: 3800 N Central Avenue, Suite 1400 Phoenix, AZ 85012 Telephone: (602) 506-6010 Fax: (602) 506-6179 Email: AQPlanning@maricopa.gov Submit Comments At: http://maricopa.gov/FormCenter/Regulatory-Outreach-17/Citizen- Comments-94 3. Rulemaking process: This rulemaking (AQ-2017-007-Rule 324) is following procedures identified in state statutes and the Maricopa County EROP Policy: County Manager Briefing: December 2017 Stakeholder Workshops: August 22, 2018 October 24, 2019 Board of Health Meeting to Initiate Regulatory Change: February 25, 2019 Notice of Proposed Rulemaking: November 24, 2020 64 Return to list of attachments Board of Health Meeting to Recommend Approval to the Board of Supervisors: April 26, 2021 Board of Supervisors Formal Meeting to set the Public Hearing: May 19, 2021 Board of Supervisors Public Hearing: June 23, 2021 4. Explanation of the rule, including the control officer's reasons for initiating the rulemaking: Rule 324 (Stationary Reciprocating Internal Combustion Engines [RICE]) limits emissions of nitrogen oxides (NOx), sulfur oxides (SOx), carbon monoxide (CO), particulate matter (PM), and volatile organic compounds (VOC) from stationary reciprocating internal combustion engines (such as electrical generators and mechanical pumps). The MCAQD is proposing to revise Rule 324 to address rule deficiencies identified by the U.S. Environmental Protection Agency (EPA) to secure full approval of Rule 324 as a revision to the Arizona State Implementation Plan (SIP). On May 4, 2016, portions of Maricopa County were designated as a moderate nonattainment area with respect to the 2008 National Ambient Air Quality Standards for Ozone. Sections 182(b)(2) and 182(f) of the Clean Air Act require jurisdictions that are classified as “moderate” or higher nonattainment to implement reasonably available control technology (RACT) for all categories of VOC sources covered by a Control Technique Guideline document as well as for all major stationary sources of NOX and VOCs that are located within the nonattainment area. EPA defines RACT as “the lowest emission limitation that a particular source is capable of meeting by the application of control technology that is reasonably available considering technological and economic feasibility”. The EPA provides guidance on RACT for sources of NOX through Alternative Control Technology (ACT) documents which offer State and local air pollution control authorities information that assists in determining NOX-RACT for air quality rules. In addition, the EPA reviews SIP- approved air quality rules from other air districts with ozone nonattainment areas to assist in determining NOX-RACT for air quality rules. In November 2016, Rule 324 was revised to implement RACT for sources of NOX. The revised rule was submitted to the EPA in June of 2017, as part of the SIP Revision for the Maricopa County Air Quality Department Ozone Rules contained in the Arizona SIP. The EPA reviewed Rule 324 and provided the MCAQD with written rule approvability and rule improvement comments for the rule. EPA staff informed MCAQD staff they would be using a conditional approval process to act on Rule 324 and the MCAQD would need to draft a commitment letter outlining revisions to Rule 324 to address the rule approvability comments. On January 28, 2019, the MCAQD submitted a Letter of Commitment for Conditional Approval of the Maricopa County RACT SIP to the EPA. Later, on December 5, 2019, the MCAQD submitted a supplemental commitment letter to address additional rule approvability comments MCAQD received after the original commitment letter was submitted. Based on the commitment letters, the EPA published a proposed conditional approval of Rule 324 in the Federal Register on December 30, 2019 (Docket ID; EPA-R09- OAR-2019-0321). The proposed conditional approval rulemaking was available for a 30-day 65 comment period, but no comments were received. The proposed conditional approval references a Technical Support Document (TSD) which includes a thorough review of Rule 324 and MCAQD’s commitments. The TSD outlines EPA’s four (4) official rule approvability comments (“rule deficiencies”) – which preclude full approval of the rule into the SIP – as well as four (4) rule revision recommendations, which are not currently the basis for rule disapproval but are recommended for this current proposed rulemaking for Rule 324. Revisions addressing both the EPA’s identified deficiencies and recommendations have been made to the proposed draft Rule 324 (included in this notice). A link to EPA’s TSD is located under Section 5 of this notice. EPA’s final conditional approval was published on July 20, 2020. The effective date of the final rule was August 19, 2020. If the MCAQD, through the ADEQ, submits the rule revisions that the MCAQD has committed to submit within 12 months and the EPA approves the submission, then the identified deficiencies will be cured, and the rule will be approved as part of the Arizona SIP. Details about the EPA’s identified deficiencies and the MCAQD’s proposed remedies are described below, followed by the EPA rule recommendations and the MCAQD’s proposed revisions to address the recommendations. Deficiency 1: The submitted rule’s current structure of applicability and emission limits does not clearly outline a RACT limit for NOx and VOC emissions from all applicable IC engines. The MCAQD should review similar source category regulations in other jurisdictions (San Diego APCD Rule 69.4 and Yolo-Solano AQMD Rule 2.32) on how they structure clearer RACT limits that may include similar or more stringent requirements or limits for engines otherwise subject to federal requirements and standards in 40 CFR part 60, subparts IIII and JJJJ. We understand that units may need to comply with more stringent Federal standards in some cases, but a RACT limit would not interfere with a facility’s compliance with a more stringent limit. The Clean Air Act requires that RACT limitations be approved into the Federally-enforceable SIP. It is inappropriate to rely on requirements outside of the SIP, such as NSPS standards found in 40 CFR Part 60. Remedy 1: The MCAQD is proposing to restructure the rule to clarify applicability and emission limits. The MCAQD is proposing to retain existing SIP requirements for stationary RICE that are not located at a major stationary source of nitrogen oxides. The MCAQD is proposing to retain the existing numeric emission limits in SIP Rule 324 for non-emergency engines that are located at a major stationary source of nitrogen oxides (because these limits are consistent with RACT limits in other jurisdictions). Deficiency 2: The submitted rule only applies to engines rated greater than 250 bhp, and to engines greater than 50 bhp when operating at a facility whose units sum to greater than 250 bhp. The MCAQD should lower the applicability threshold to 50 bhp to be in line with other jurisdictions’ RACT rules. The current rule also does not clearly state compliance requirements for 50 bhp engines summed at a 250 bhp facility. Remedy 2: 66 The MCAQD is proposing to lower the applicability threshold to 50 bhp for stationary RICE located at a major source of nitrogen oxides. The MCAQD is also proposing to clarify what emission limits apply to non-emergency engines rated above 50 bhp that are located at a major stationary source of nitrogen oxides. Deficiency 3: The submitted rule allows for flexibility in the treatment of replacement engines. In section 104.6, emergency engines that serve as backup to replace non-emergency engines may do so until the non-emergency engine is repaired, but this time span is otherwise unbounded, and may operate above RACT limits. The MCAQD should restrict the amount of time allowed to operate that emergency engine, or the backup engine should be required to meet RACT limits. Current rule provisions in sections 207 and 306 also allow for engines that are deemed equivalent or identical to replace existing engines to be treated the same as the engine being replaced, but there are no requirements for replacement engines to quantify emissions equivalency or reductions. Remedy 3: The MCAQD is proposing to incorporate constraints on the amount of time an emergency engine can be used to replace a non-emergency engine when the non-emergency engine has failed, and to clarify in the definition for “emergency engine” the amount of time that is allowed for emergency engine operations. The MCAQD is also proposing to remove provisions related to equivalent replacement engines from Rule 324. Deficiency 4: The submitted rule does not specify a compliance determination interval for engines, beyond at the Control Officer’s discretion. This provision is found in section 501.1b. Remedy 4: The MCAQD is proposing to include compliance determination intervals for non- emergency engines located at both major sources and for those not located at major sources. Recommendation 1: Section 103.1(e) exempts stationary engines at a nuclear power plant used for safety reasons. Please describe the engines used at these facilities and explain why such plants cannot use compliant engines for safety applications. Revision 1: The MCAQD is proposing to change the full exemption to a partial exemption as outlined under proposed section 108. Recommendation 2: Section 104 and section 205 provide special considerations for emergency engines. Please explain why these engines need special consideration, when these engines already exist on site. Please characterize the number of sources that have non-compliant engines and would qualify under these partial exemptions. Revision 2: 67 The MCAQD has reviewed RACT rules for engines in other jurisdictions and determined that many jurisdictions require maintenance for emergency engines. This is also consistent with the NSPS and NESHAP for stationary engines (40 CFR 60.4211, 60.4243, and 63.6625(e)). Therefore, the MCAQD is proposing that engine maintenance is RACT for emergency engines. In addition, MCAQD is also proposing to require an hour meter to determine compliance with operating limits and fuel records to determine compliance with fuel requirements. Recommendation 3: Section 105 describes a low use threshold that varies between 100-200 hours per year depending on whether the engine is above or below a 1000 bhp threshold. How many engines are in each size class, and why is this threshold a reasonable cut-point? Revision 3: MCAQD is proposing to limit the partial exemption in Section 105 to those low use non- emergency engines that are onsite and in use before the date of rule adoption. Recommendation 4: Section 103.1.g exempts stationary engines used for training purposes. The term “training” is undefined. Please define what activities constitute valid training with respect to engines in this context. Revision 4: The MCAQD is proposing to remove this exemption. This exemption has not been used in the past and training engines that operate less than 100 hours per year may still qualify for the low-use exemption in Section 105 of this rule. Additional revisions were made to address stakeholder and staff comments, which can be discerned in the “strikeout and underline” version of the rule included in this notice and described in all Stakeholder Workshop notices and workshop slides/presentations that are posted on the EROP website. 5. Studies relied on in the control officer's evaluation of or justification for the rule and where the public may obtain or review the studies, all data underlying the studies, any analysis of the studies and other supporting material. United States Environmental Protection Agency Region IX Air Division (2019). Technical Support Document for EPA’s Rulemaking for the Arizona State Implementation Plan Regarding Rule 324, “Stationary Reciprocating Internal Combustion Engines (RICE). https://www.regulations.gov/document?D=EPA-R09-OAR-2019-0321-0012 6. An economic, small business and consumer impact statement: The following discussion addresses each of the elements required for an economic, small business and consumer impact statement, as prescribed by A.R.S. §§ 41-1055, subsections A, B and C, and 41-1035: An identification of the proposed rulemaking, including all of the following: This rulemaking is proposing to revise Rule 324. (a) The conduct and its frequency of occurrence that the rule is designed to change. 68 The MCAQD is proposing to revise Rule 324 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 324 into the Arizona SIP. The revisions are explained in more detail in Item #4 of this notice. (b) The harm resulting from the conduct the rule is designed to change and the likelihood it will continue to occur if the rule is not changed. The MCAQD is proposing to revise Rule 324 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 324 into the Arizona SIP and avoid sanctions and imposition of a Federal Implementation Plan (FIP) under the Clean Air Act. (c) The estimated change in frequency of the targeted conduct expected from the rule change. The MCAQD is proposing to revise Rule 324 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 324 into the Arizona SIP. As with other rules, the MCAQD will use education, outreach, and other compliance assurance tools to increase the number of people in compliance with the revised rule. The MCAQD strives to achieve the highest possible compliance rates. A brief summary of the information included in the economic, small business and consumer impact statement. The economic, small business and consumer impact statement addresses each of the elements required for an economic, small business and consumer impact statement, as prescribed by A.R.S. §§ 41-1055, subsections A, B, and C, and 41-1035. Name and address of agency employees who may be contacted to submit or request additional data on the information included in the economic, small business and consumer impact statement. Name: Scott Kahldon or Kimberly Butler Maricopa County Air Quality Department Planning and Analysis Division Address: 3800 N Central Avenue, Suite 1400 Phoenix, AZ 85012 Telephone: (602) 506-6010 Fax: (602) 506-6179 Email: AQPlanning@maricopa.gov Submit Comments At: http://maricopa.gov/FormCenter/Regulatory-Outreach-17/Citizen- Comments-94 An identification of the persons who will be directly affected by, bear the costs of or directly benefit from the proposed rulemaking. This rulemaking will directly affect facilities in Maricopa County that have stationary reciprocating internal combustion engines with a rated brake horsepower (rated bhp) of: (1) Greater than 125, if the stationary RICE is not located at a major source of NOx emissions, 69 (2) Greater than 50, if the stationary RICE is not located at a major source of NOx emissions and the maximum aggregated rated bhp of all stationary RICE at the stationary source is more than 125 when all engines with a rated bhp of more than 50 are aggregated, (3) Greater than 50, if the stationary RICE is located at a major source of NOx emissions, and (4) Any nonroad engine, with a rated bhp of greater than 125, that is located at a stationary source that emits or has the potential to emit any regulated air pollutant greater than the permitting thresholds defined in Rule 100. A cost benefit analysis of the following: (a) The probable costs and benefits to the implementing agency and other agencies directly affected by the implementation and enforcement of the proposed rulemaking. This rulemaking should not impose any new costs on the MCAQD or on any other agencies affected by the proposed rulemaking. (b) The probable costs and benefits to a political subdivision of this state directly affected by the implementation and enforcement of the proposed rulemaking. The MCAQD is proposing to revise Rule 324 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 324 into the Arizona SIP for RACT and avoid sanctions and imposition of a FIP under the Clean Air Act. In general, the majority of political subdivisions to which this rule applies will not incur significant new costs based on the proposed revisions; however, some political subdivisions may incur costs required to comply with the revised compliance determination methods in Section 500, specifically the revised performance test requirements. In current Rule 324, a political subdivision required to conduct a performance test to demonstrate compliance under Section 500 must do so upon request by the Control Officer. Under Section 500 in the proposed rule, a political subdivision required to conduct a performance test to demonstrate compliance will have to do so at least once every 5 years. For some political subdivisions, this may require new or additional performance testing which will lead to increased costs. In addition, new or additional performance testing may lead to increased cases of noncompliance, and for those political subdivisions that are out of compliance, there will be increased costs to come back into compliance. (c) The probable costs and benefits to businesses directly affected by the proposed rulemaking, including any anticipated effect on the revenues or payroll expenditures of employers who are subject to the proposed rulemaking. The MCAQD is proposing to revise Rule 324 to remedy deficiencies identified by the EPA. This rulemaking is required to secure approval of Rule 324 into the Arizona SIP for RACT and avoid sanctions and imposition of a FIP under the Clean Air Act. In general, the majority of businesses to which this rule applies will not incur significant new costs based on the proposed revisions; however, some businesses may incur costs required to comply with the revised compliance determination methods in Section 500, specifically the revised performance test requirements. In current Rule 324, a business required to conduct a performance test to demonstrate compliance under Section 500 70 must do so upon request by the Control Officer. Under Section 500 in the proposed rule, a business required to conduct a performance test to demonstrate compliance will have to do so at least once every 5 years. For some businesses, this may require new or additional performance testing which will lead to increased costs. In addition, new or additional performance testing may lead to increased cases of noncompliance, and for those businesses that are out of compliance, there will be increased costs to come back into compliance. A general description of the probable impact on private and public employment in businesses, agencies and political subdivisions of this state directly affected by the proposed rulemaking. This rulemaking should not have a significant impact on private or public employment in businesses, agencies, and political subdivisions of this state. A statement of the probable impact of the proposed rulemaking on small businesses. The statement shall include: (a) An identification of the small businesses subject to the proposed rulemaking. Small businesses subject to this rulemaking are those facilities in Maricopa County that have stationary reciprocating internal combustion engines that meet the requirements of Section 102 of the draft rule included in this notice. (b) The administrative and other costs required for compliance with the proposed rulemaking. In general, the majority of businesses to which this rule applies will not incur significant new costs based on the proposed revisions; however, some businesses may incur costs required to comply with the revised compliance determination methods in Section 500, specifically the revised performance test requirements. In current Rule 324, a business required to conduct a performance test to demonstrate compliance under Section 500 must do so upon request by the Control Officer. Under Section 500 in the proposed rule, a business required to conduct a performance test to demonstrate compliance will have to do so at least once every 5 years. For some businesses, this may require new or additional performance testing which will lead to increased costs. In addition, new or additional performance testing may lead to increased cases of noncompliance, and for those businesses that are out of compliance, there will be increased costs to come back into compliance. (c) A description of the methods that the agency may use to reduce the impact on small businesses. i. Establish less stringent compliance or reporting requirements in the rule for small businesses. In general, this rulemaking does not impose any significant new compliance requirements on small businesses and does not establish any significant new reporting requirements for small businesses. However, some small businesses will be required to comply with the revised compliance determination methods in Section 500, specifically the revised performance test requirements described above. For some small businesses, this may require new or additional performance testing. Less stringent performance testing requirements are not feasible because the revised 71 testing requirements are required to remedy one of the deficiencies identified by the EPA in the rule. ii. Establish less stringent schedules or deadlines in the rule for compliance or reporting requirements for small businesses. In general, this rulemaking does not impose any significant new schedules or deadlines for compliance and reporting requirements on small businesses. However, some small businesses will be required to comply with the revised compliance determination methods in Section 500, specifically the revised performance test requirements described above. For some small businesses, this may require new or additional performance testing. Less stringent performance testing requirements are not feasible because the revised testing requirements are required to remedy one of the deficiencies identified by the EPA in the rule. iii. Consolidate or simplify the rule's compliance or reporting requirements for small businesses. In general, this rulemaking does not impose any significant new compliance requirements on small businesses and does not establish any significant new reporting requirements for small businesses. However, some small businesses will be required to comply with the revised compliance determination methods in Section 500, specifically the revised performance test requirements described above. For some small businesses, this may require new or additional performance testing. Less stringent performance testing requirements are not feasible because the revised testing requirements are required to remedy one of the deficiencies identified by the EPA in the rule. iv. Establish performance standards for small businesses to replace design or operational standards in the rule. In general, this rulemaking does not impose any significant new compliance requirements on small businesses and does not establish any significant new reporting requirements for small businesses. However, some small businesses will be required to comply with the revised compliance determination methods in Section 500, specifically the revised performance test requirements described above. For some small businesses, this may require new or additional performance testing. Less stringent performance testing requirements are not feasible because the revised testing requirements are required to remedy one of the deficiencies identified by the EPA in the rule. v. Exempt small businesses from any or all requirements of the rule. This rulemaking contains some partial and full exemptions as outlined in sections 103-108 within this rule. (d) The probable cost and benefit to private persons and consumers who are directly affected by the proposed rulemaking. This rulemaking should not result in any significant costs for private persons and consumers. A statement of the probable effect on state revenues. 72 No significant effect on state revenues is expected by this rulemaking. A description of any less intrusive or less costly alternative methods of achieving the purpose of the proposed rulemaking, including the monetizing of the costs and benefits for each option and providing the rationale for not using nonelected alternatives. The purpose of this rulemaking is to revise Rule 324 to remedy deficiencies identified by the EPA. This rule making is required to secure approval of Rule 324 into the State Implementation Plan (SIP) for RACT and avoid sanctions and imposition of a Federal Implementation Plan (FIP) under the Clean Air Act. A description of any data on which a rule is based with a detailed explanation of how the data was obtained and why the data is acceptable data. Not applicable. 7. The proposed effective date of the rule: The proposed effective date of this rulemaking is June 23, 2021. 8. Such other matters as are prescribed by statute and that are applicable to the county or to any specific rule or class of rules: Under A.R.S. § 49-479(C), a county may not adopt a rule or ordinance that is more stringent than the rules adopted by the Director of the Arizona Department of Environmental Quality (ADEQ) for similar sources unless it demonstrates compliance with the applicable requirements of A.R.S. §49-112. § 49-112 County regulation; standards § 49-112(A) When authorized by law, a county may adopt a rule, ordinance or regulation that is more stringent than or in addition to a provision of this title or rule adopted by the director or any board or commission authorized to adopt rules pursuant to this title if all of the following requirements are met: 1. The rule, ordinance or regulation is necessary to address a peculiar local condition. 2. There is credible evidence that the rule, ordinance or regulation is either; (a) Necessary to prevent a significant threat to public health or the environment that results from a peculiar local condition and is technically and economically feasible. (b) Required under a federal statute or regulation or authorized pursuant to an intergovernmental agreement with the federal government to enforce federal statutes or regulations if the county rule, ordinance or regulation is equivalent to federal statutes or regulation. 3. Any fee or tax adopted under the rule, ordinance or regulation does not exceed the reasonable costs of the county to issue and administer the permit or plan approval program. § 49-112(B) 73 When authorized by law, a county may adopt rules, ordinances or regulations in lieu of a state program that are as stringent as a provision of this title or rule adopted by the director or any board or commission authorized to adopt rules pursuant to this title if the county demonstrates that the cost of obtaining permits or other approvals from the county will approximately equal or be less than the fee or cost of obtaining similar permits or approvals under this title or any rule adopted pursuant to this title. If the state has not adopted a fee or tax for similar permits or approvals, the county may adopt a fee when authorized by law in the rule, ordinance or regulation that does not exceed the reasonable costs of the county to issue and administer that permit or plan approval program. The department is in compliance with A.R.S. §§ 49-112 (A) and (B). Rule 324 meets A.R.S. § 49-112 (A) (1) by demonstrating that the rule is necessary to address a peculiar local condition, in that Maricopa County fails to meet the 8-hour NAAQS for ozone. Rule 324 meets the requirements of A.R.S. § 49-112 (A) (2) (b), in that Maricopa County is required by federal law to revise existing rules to address RACT for the facilities that have stationary reciprocating internal combustion engines. As there is no new fee or tax associated with this proposed rulemaking, the department also affirms that Rule 324 meets the requirements of A.R.S. § 49-112 (A) (3) and A.R.S. § 49-112 (B). 9. List of all previous notices posted to the Maricopa County EROP website addressing the proposed rule and a concise explanatory statement, as prescribed by A.R.S. § 49- 471.07, subsection B: (a) List of all previous notices posted to the Maricopa County EROP website addressing the proposed rule: Notice Date of Posting Briefing Notification to County Manager: January 26, 2018 Notice of Stakeholder Workshop: August 03, 2018 October 09, 2019 Notice of Board of Health Meeting to Initiate Regulatory Change: February 08, 2019 Notice of Proposed Rulemaking: November 24, 2020 Notice of Board of Health Meeting to Make Recommendations to the Board of Supervisors: April 12, 2021 (b) The following discussion addresses each of the elements required for a concise explanatory statement, as prescribed by A.R.S. § 49-471.07, subsection B: i. A description of any change between the proposed rule or ordinance, the final rule or ordinance or notice of final supplemental rule or ordinance. The following changes were made after the Notice of Proposed Rulemaking was published on November 24, 2020. 1. The MCAQD revised the definition of Part(s) Per Million, Dry Volume (PPMDV) to be consistent between Rules 322, 323, and 324. The section was revised as indicated below: 74 Section 215: PARTS PER MILLION BY VOLUME DRY (PPMVD): A unit of proportion used to express concentration that is corrected to a dry basis. 2. Based off of staff comments, the MCAQD removed the oxygen correction from the definition of Part(s) Per Million, Dry Volume and placed it closer to the corresponding emission limits in the rule to improve rule clarity. The MCAQD added an asterisk to denote the phrase “ppmvd emission standards are corrected to 15% oxygen” to the tables indicated below: Table 324-1 Table 324-2 Table 324-3 3. The MCAQD revised the acronym “ppmdv” to “ppmvd” to match the revised definition for Parts Per Million By Volume Dry (PPMVD). This revision was added to the tables listed below. Table 324-1 Table 324-2 Table 324-3 4. The MCAQD removed the language “in accordance with the requirements of Rule 270 of these rules” in section 501.4. The section was revised as indicated below: Section 501.4: Performance Test Conditions: Performance tests shall be conducted using the test methods listed in Section 503 of this rule. Testing for stationary RICE shall be completed at either the maximum operating load or no less than 80% of the rated bhp. If the owner or operator of an engine demonstrates to the Control Officer that the engine cannot operate at these conditions, then emissions source testing shall be performed at the highest achievable continuous rated bhp or under the typical duty cycle or typical operational mode of the engine. The result of the performance test shall be the arithmetic mean of the results of three test runs. Each test run shall have a minimum sample time of one hour. 5. Based off of stakeholder comments, the MCAQD revised the applicability language in Section 102.1.d to clarify which nonroad engines are subject to the recordkeeping requirements in Rule 324. This section was revised as indicated below: Section 102.1.d: Any nonroad engine, with a rated bhp of greater than 125, that is located at a stationary source that emits or has the potential to emit any regulated air pollutant greater than the permitting thresholds defined in Rule 100 of these rules. For the purpose of this Rule, a nonroad engine is any internal combustion engine that by itself or in or on a piece of equipment is portable or transportable, meaning designed to be and capable of being carried or moved from one location to another. Indicia of transportability include but are not limited to, wheels, skids, carrying handles, dollies, trailers, or platforms. In addition, the MCAQD revised the nonroad engine records requirements in Section 502.6 to clarify the records specified in Section 502.6.b.(1), (2) and (3) are 75 only required to be kept for those nonroad engines located at a stationary source greater than 14 consecutive days. This section was revised as indicated below: Section 502.6: Nonroad Engine Records: An owner or operator of a nonroad engine shall maintain the following records for each non-road engine: a. Date that each engine is brought to the stationary source; and b. For engines located at a stationary source greater than 14 consecutive days: (1) Make, model, serial number, and rated capacity (bhp hours) of the engine; and (2) Date of each instance in which the engine is moved from its existing location, and the reason why the engine was moved; and (3) Fuel type and sulfur content of the fuel. Return to list of attachments ii. A summary of the comments and arguments for and against the notice and the county’s response to the comments and arguments. The following discussion evaluates the arguments for and against the rule and includes responses to comments received on the proposed rule or the preamble in the Notice of Proposed Rulemaking. The MCAQD received written comments from four (4) stakeholders. All of the comments were reviewed and evaluated by the MCAQD. Comment #1: The hours of operation for emergencies should be specified in this section and testing, reliability and maintenance hours should be grouped together as non-emergency hours. Suggested language is: “Monthly and rolling twelve-month total hours of operation, emergency hours of operation, and non-emergency hours of operation (including hours for testing, reliability, and maintenance).” Response #1: The MCAQD considered your comment and revised the language in Section 502.2 to read as follows: Operation Records: An owner or operator of a stationary RICE shall maintain records of the monthly and 12-month rolling total hours of operation for each stationary RICE. For emergency engines, the operation records shall also include: a. Monthly and annual hours of operation for reliability related activities such as engine readiness, calibration, or maintenance, or to prevent the occurrence of an unsafe condition during electrical system maintenance; and b. The number of operating hours for emergency use and an explanation for the emergency use. Comment #2: We recently had several air permit inspections for our general permits that are for our emergency generators. We have been having these inspections every other year for our facilities and not had any major issues during the inspections. Each generator has a logbook that has a monthly record for the checks that take place, any operation or other issues that occur. Historically, these records were used to calculate the 12-month hours of operation to show compliance with permit conditions. However, during our recent inspections, we were informed that we had not been keeping a monthly rolling record of hours and that we needed to begin this for our general permitted sites. I've reviewed the permit and Rule 324 and understand that this is required but seems like an unnecessary effort if we keep a monthly log of 76 hours. The previous 12 months can easily be calculated by taking March 2019 hours and subtracting March 2018 hours to show the current 12 months of hours of operation. The City of Chandler emergency generators typically run less than a couple hours a month, often times even less than a couple hours. The City understands the permit language and will do what is needed to maintain compliance. However, since our sites have been inspected frequently and this has not previously been noted nor has it been noted as a compliance issue. The City believes that for remote sites that also run very limited hours that the information needed to determine hours of operation can be calculated from the on-site logbooks during inspections. Our emergency generators are typically at unmanned facilities, have limited use and would require additional effort and resources to collect and track this information. We hope to see this requirement addressed through logbook information that is maintained at each site and not a requirement to create spreadsheets for each generator (we have over 30 permitted sites). Since Rule 324 is currently being reviewed and possibly amended we hope that this issue can be addressed during this process. We would like to see this section clarified that for limited use, unmanned sites that the on-site logbook can be used to determine the 12-month hours of operation. Response #2: The MCAQD considered your comment and determined that records of the 12-month rolling total hours of operation are needed to ensure compliance with emission and/or operation limits. The information can be recorded in the logbook or using any other method as long as the required records are maintained. Comment #3: We have reviewed the language and our operations across our fleet. We are requesting the following change to the verbiage (see below). We have engines from 15 different manufactures (some are no longer in business) and only use a single qualified service provider. The use of one contractor to conduct engine is preferred by our Supply Chain because of the clearance required to work at some of our sites as well as safety hazards associated with our facilities. There are some service providers that have safety records that prohibit them from working at our sites entirely. An owner or operator of a stationary RICE shall maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the written maintenance schedule provided by the manufacturer’s authorized a qualified service provider. If the manufacturer's written instructions are not available and the manufacturer’s authorized qualified service provider does not provide a written maintenance schedule, the owner or operator shall conduct preventative maintenance according to the following schedule, including all of the following procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine: Response #3: The MCAQD considered your comment and revised the language in Section 302 to read as follows: MAINTENANCE REQUIREMENTS: An owner or operator of a stationary RICE shall maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the maintenance schedule provided by the manufacturer’s authorized service provider. Alternatively, the owner or operator shall conduct preventative maintenance according to the following schedule, including all of the following tuning procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine. 77 Comment #4: Thanks for the opportunity to provide comments in your chat room during the October 24, 2019 workshop. I notice of you could not accept a proposed comment [KB-A30] about changing the term “manufacturer’s authorized service provider” with the term “qualified service provider” because this is not a recognized term in use by the EPA. We agree with the commenters concern about the term “authorized service provider” because the term in our opinion raises proprietary issues related to maintenance documentation provided by engine and/or emergency generator manufacturers exclusively to authorized dealerships. A regular maintenance provider may have authorizations from various engine manufacturers but may not be able to get authorizations from for example emergency generator manufacturers who have their own non-road engines installed. We suggest you consider alterative options and include language in Section 302 about “or authorization from a manufacturer of a similar engine type” and “in accordance with recommendations from the manufacturer of a similar engine type.” Response #4: The MCAQD considered your comment and revised the language in Section 302 to read as follows: MAINTENANCE REQUIREMENTS: An owner or operator of a stationary RICE shall maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the maintenance schedule provided by the manufacturer’s authorized service provider. Alternatively, the owner or operator shall conduct preventative maintenance according to the following schedule, including all of the following tuning procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine. Comment #5: I have a few comments for draft Rule 324, which deals explicitly with non-road engines. I understand the purpose of tracking non-road engines and the amount of time they are onsite to ensure there is no circumvention of the rules by using a non-road engine as a stationary engine. Unfortunately, the record-keeping requirement can be quite burdensome for facilities with special events that use non- road generators for a minimal amount of time. Almost all non-road generators are brought onto the site and removed in less than a week, and many within 24 hours. Could there be a timeframe, such as seven days, that if a non-road engine is brought onsite for more than seven days, then section 502.6 applies? Additionally, the serial number requirement in Section 502.6 b. can be difficult to obtain depending on the situation. Rental companies will have the make, model, and capacity readily available for the non-road engines being rented, but not the specific serial number sent to the site. If the non-road engine is brought onto the site for a single night event, it can be challenging to obtain the serial number for an event that lasts three hours at night. Response #5: The MCAQD considered your comments and revised the language in Section 502.6 to read as follows: Nonroad Engine Records: An owner or operator of a nonroad engine shall maintain the following records for each non-road engine: a. Date that each engine is brought to the stationary source ; and b. For engines located at a stationary source greater than 14 consecutive days: (1) Make, model, serial number, and rated capacity (bhp hours) of the engine; and (2) Date of each instance in which the engine is moved from its existing location, and the reason why the engine was moved; and (3) Fuel type and sulfur content of the fuel. Additionally, the MCAQD revised the applicability language in Section 102.1.d to clarify which nonroad engines are subject to the recordkeeping requirements in Rule 324. Section 78 102.1.d now reads as follows: Any nonroad engine, with a rated bhp of greater than 125, that is located at a stationary source that emits or has the potential to emit any regulated air pollutant greater than the permitting thresholds defined in Rule 100 of these rules. For the purpose of this Rule, a nonroad engine is any internal combustion engine that by itself or in or on a piece of equipment is portable or transportable, meaning designed to be and capable of being carried or moved from one location to another. Indicia of transportability include but are not limited to, wheels, skids, carrying handles, dollies, trailers, or platforms. Return to list of attachments EXACT WORDING OF THE RULE MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III - CONTROL OF AIR CONTAMINANTS RULE 324 STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINES (RICE) INDEX SECTION 100 – GENERAL 101 PURPOSE 102 APPLICABILITY 103 EXEMPTIONS 104 PARTIAL EXEMPTIONS FOR EMERGENCY ENGINES 105 PARTIAL EXEMPTIONS FOR LOW USAGE NON-EMERGENCY ENGINES 106 PARTIAL EXEMPTION FOR NON-EMERGENCY ENGINES SUBJECT TO 40 CFR PART 63, SUBPART ZZZZ NONROAD ENGINES 107 PARTIAL EXEMPTION FOR NON-EMERGENCY ENGINES THAT ARE LOCATED AT A MAJOR SOURCE OF NITROGEN OXIDES (NOX) 108 PARTIAL EXEMPTION FOR STATIONARY RICE THAT ARE LOCATED AT A NUCLEAR POWER PLANT SECTION 200 – DEFINITIONS 201 AFTERCOOLER/INTERCOOLER 202 ALTERNATIVE FUELS 202 203 COGENERATION UNIT 204 COMMISSIONING PERIOD 203 205 COMPRESSION-IGNITION ENGINE 204 DIESEL ENGINE 205 206 EMERGENCY ENGINE 79 206 ENGINE FAMILY 207 EQUIVALENT REPLACEMENT ENGINE 207 GASOLINE 208 IDENTICAL REPLACEMENT ENGINE 209 LEAN-BURN ENGINE 210 LIQUEFIED PETROLEUM GAS (LPG) 210 211 LOCATION 212 LOW SULFUR OIL 213 NATURAL GAS 211 214 NON-EMERGENCY ENGINE 212 NONROAD INTERNAL COMBUSTION (IC) ENGINE 213 215 PARTS(S) PER MILLION, DRY BY VOLUME DRY (PPMDVD) 214 216 RATED BRAKE HORSEPOWER (RATED BHP) 217 RECONSTRUCTED 215 218 RICH-BURN ENGINE 216 219 SPARK-IGNITION ENGINE 217 220 STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINE (RICE) 218 221 SULFUR OXIDES (SOX) 219 222 ULTRA LOW SULFUR OIL DIESEL 220 223 WASTE DERIVED FUEL GAS SECTION 300 – STANDARDS 301 LIMITATIONS FOR STATIONARY RICE – FUEL REQUIREMENTS 302 GOOD COMBUSTION PRACTICES/TUNING PROCEDURES FOR STATIONARY RICE MAINTENANCE REQUIREMENTS 303 LIMITATIONS FOR STATIONARY RICE - OPACITY 304 LIMITATIONS FOR NON-EMERGENCY ENGINES - 250 RATED BHP OR GREATER 305 EFFICIENCY ALLOWANCE 306 305 EQUIVALENT REPLACEMENT ENGINE OR IDENTICAL REPLACEMENT ENGINE 307 MODIFICATION TO A STATIONARY RICE 308 306 NON-RESETTING TOTALIZING HOUR METER SECTION 400 – ADMINISTRATIVE REQUIREMENTS 80 401 COMPLIANCE SCHEDULE-STATIONARY RICE BEING REMOVED FROM SERVICE 402 COMPLIANCE SCHEDULE-NON-RESETTING TOTALIZING HOUR METER 403 COMPLIANCE SCHEDULE-ENGINES AT A SOURCE THAT BECOMES A MAJOR SOURCE SECTION 500 – MONITORING AND RECORDS 501 COMPLIANCE DETERMINATION 502 RECORDKEEPING/RECORDS RETENTION 503 COMPLIANCE DETERMINATION-TEST METHODS INCORPORATED BY REFERENCE 81 Adopted 10/22/2003; Revised 10/17/2007; Revised 11/02/2016; Revised MM/DD/YYYY MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III – CONTROL OF AIR CONTAMINANTS RULE 324 STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINES (RICE) SECTION 100 – GENERAL 101 PURPOSE: To limit carbon monoxide (CO), nitrogen oxides (NOX), sulfur oxides (SOX), volatile organic compounds (VOCs), and particulate matter (PM) emissions from stationary reciprocating internal combustion engines (RICE). 102 APPLICABILITY: 102.1 This rule applies to: a spark-ignition engine or compression-ignition engine including stationary RICE used in cogeneration, with a rated brake horsepower (rated bhp) of greater than 250. This rule also applies to a combination of stationary RICE each with a rated bhp greater than 50 used at a source, whose maximum aggregate rated bhp is greater than 250. a. Any stationary RICE, including stationary RICE used in cogeneration, with a rated brake horsepower (rated bhp) of greater than 125, if the stationary RICE is not located at a major source of NOX emissions; b. Any stationary RICE, including stationary RICE used in cogeneration, with a rated bhp of more than 50 if the stationary RICE is not located at a major source of NOX emissions and the maximum aggregated rated bhp of all stationary RICE at the stationary source is more than 125 when all engines with a rated bhp of more than 50 are aggregated; c. Any stationary RICE, including stationary RICE used in cogeneration, with a rated brake horsepower (rated bhp) of greater than 50, if the stationary RICE is located at a major source of NOX emissions; and d. Any nonroad engine, with a rated bhp of greater than 125, that is located at a stationary source that emits or has the potential to emit any regulated air pollutant greater than the permitting thresholds defined in Rule 100 of these rules. For the purpose of this Rule, a nonroad engine is any internal combustion engine that by itself or in or on a piece of equipment is portable or transportable, meaning designed to be and capable of being carried or moved from one location to another. Indicia of transportability include but are not limited to, wheels, skids, carrying handles, dollies, trailers, or platforms. 102.2 NSPS: In addition to this rule, a stationary RICE may be subject to New Source Performance Standards (NSPS) in Rule 360 of these rules. A stationary RICE subject to this rule that is also subject to the federal standards of performance set forth in 40 CFR Part 60, Subpart IIII for compression-ignition engines or 40 CFR Part 60, Subpart JJJJ for spark-ignition engines shall comply with the most stringent 82 requirements. Whenever more than one provision in this rule applies to such engine or whenever a provision in this rule and a provision in the federal standards apply to such engine, the provision or combination of provisions resulting in the lowest rate of emissions shall apply, unless otherwise specifically exempted or designated. 102.3 NSPS & NESHAP: In addition to this rule, a stationary RICE may be subject to New Source Performance Standards (NSPS) in Rule 360 and/or National Emission Standards for Hazardous Air Pollutants (NESHAP) in Rule 370 of these rules. Whenever more than one provision in this rule applies to such engine or whenever a provision in this rule and a provision in the federal standards apply to such engine, the provision or combination of provisions resulting in the lowest rate of emissions shall apply, unless otherwise specifically exempted or designated. 103.1 103 EXEMPTIONS: The following types of stationary RICE are exempt from all of the requirements of this rule but shall comply with Rule 300 (Visible Emissions) of these rules: a. A rotary engine, including gas turbines, jet engines. b. 103.1 A stationary RICE used directly and exclusively for engine research including engine development, and subsequent engine performance verification for the purpose of either engine emission control techniques or engine efficiency improvements. c. 103.2 A non-emergency engine when it is operated for purposes of performance verification and testing by the owner or operator or by a manufacturer or distributor of such equipment for the purpose of performance verification and testing at the production facility. d. 103.3 A compressed gas stationary RICE used for solar testing and research programs. e. A stationary RICE operated as an emergency engine or other equipment at a nuclear power plant that must run for safety reasons and/or operational tests to meet requirements imposed by the Nuclear Regulatory Commission. f. 103.4 A stationary RICE test stand used for evaluating engine performance. g. A stationary RICE used for training purposes as long as the total number of hours of the operation does not exceed 100 hours per calendar year per engine. 104 PARTIAL EXEMPTIONS FOR EMERGENCY ENGINES: A stationary RICE operated as an emergency engine, as defined in this rule, for any of the following reasons shall comply only with the provisions in Sections 301, 303, 306, 307, 400, 502.1 and 502.4 be exempt from Sections 304, 501.1, 501.2, 501.3, and 501.4 of this rule when: 104.1 Used only for power when normal power service fails from the serving utility or if onsite electrical transmission or onsite power generation equipment fails. 104.2 Used only for the emergency pumping of water resulting from a flood, fire, lightning strikes, police action or for any other essential public services which affect public health and safety. 104.3 Used for lighting airport runways. 104.4 Used for sewage overflow mitigation and/or prevention. 83 104.5 Used for reliability-related activities such as engine readiness, calibration, or maintenance or to prevent the occurrence of an unsafe condition during electrical system maintenance, as long as the total number of hours of the operation for these purposes does not exceed 100 hours per calendar year per engine as evidenced by an installed non-resettable non-resetting totalizing hour meter. For the purposes of this rule, hours of operation during the commissioning period do not count towards the 100 hour per calendar year limit on hours of operation for reliability-related activities. 104.6 Used as the non-emergency engine when the non-emergency engine has failed, but only for such time as is needed to repair the non-emergency engine. For the purposes of this exemption, if the non-emergency engine is not repaired and returned to service within 12 months, or if the emergency engine is used as the non-emergency engine for more than 50 hours, whichever occurs first, the emergency engine shall be reclassified as a non-emergency engine and shall comply with all requirements of this rule that are applicable to non-emergency engines. 104.7 Used to operate standby emergency water pumps for fire control that activate when sensors detect low water pressure. 105 PARTIAL EXEMPTIONS FOR LOW USAGE NON-EMERGENCY ENGINES: The following low usage non-emergency engines onsite and in use before [date of rule adoption] shall comply only with the provisions in Sections 301, 303, 306, 307, 400, 502.1 and 502.4 be exempt from Sections 304, 501.1, 501.2, 501.3, 501.4, and 502.6 of this rule for: 105.1 Each engine with a rated bhp at or below 1000 that operates less than 200 hours per calendar year as evidenced by an installed non-resettable non-resetting totalizing hour meter. 105.2 Each engine with a rated bhp above 1000 that operates less than 100 hours per calendar year as evidenced by an installed non-resettable non-resetting totalizing hour meter. 106 PARTIAL EXEMPTION FOR NON-EMERGENCY ENGINES SUBJECT TO 40 CFR PART 63, SUBPART ZZZZ NONROAD ENGINES: A stationary RICE subject to the federal standards of performance set forth in 40 CFR Part 63, Subpart ZZZZ shall comply only with the provisions in Sections 502.1, 502.2, and 502.3 of this rule. Each nonroad engine shall comply with Rule 300 of these rules and Section 502.6 of this rule, but shall be exempt from all other requirements of this rule. 107 PARTIAL EXEMPTION FOR NON-EMERGENCY ENGINES THAT ARE LOCATED AT A MAJOR SOURCE OF NOX: A non-emergency engine that is located at a major source of NOX shall not be required to comply with Section 501.2 of this rule during the five year period beginning on January 1st of the year in which the engine was manufactured, if the owner or operator provides documentation that the non-emergency engine is certified by the manufacturer to comply with emission limits in 40 CFR 60 subpart IIII or 40 CFR 60 subpart JJJJ that are more stringent than the applicable emission limit(s) in Table 324-3 of this rule, and provides documentation that the non-emergency engine is installed, operated, and maintained in accordance with the manufacturer's specifications. 84 108 PARTIAL EXEMPTION FOR STATIONARY RICE THAT ARE LOCATED AT A NUCLEAR POWER PLANT: A stationary RICE that is located at a nuclear power plant and is operated solely for the following reasons shall comply only with the provisions in Sections 301, 302, 306, 402, 501.5, 502.1, 502.3, 502.4, and 502.5 of this rule: 108.1 Used for safety reasons and for operational tests required by the Nuclear Regulatory Commission. 108.2 Used for power when normal power service fails from the serving utility or if onsite electrical transmission or onsite power generation equipment fails. 108.3 Used for the emergency pumping of water resulting from a flood, fire, lightning strikes, police action or for any other operation that is essential to public health and safety. 108.4 Used to initiate operation of onsite emergency power generation equipment. 108.5 Used for reliability-related activities such as engine readiness, calibration, or maintenance or to prevent the occurrence of an unsafe condition during electrical system maintenance. Hours of operation for reliability-related activities shall not exceed 100 hours per year unless the reliability-related activities are recommended or required by the federal, state, or local government and the owner or operator maintains records demonstrating that the reliability-related activities are recommended or required. SECTION 200 – DEFINITIONS: For the purpose of this rule, the following definitions shall apply, in addition to those definitions found in Rule 100 (General Provisions and Definitions) of these rules. In the event of any inconsistency between any of the Maricopa County Air Pollution Control Rules, the definitions in this rule take precedence. 201 AFTERCOOLER/INTERCOOLER: A system that cools the engine intake air or air/fuel mixture after the air exits the turbocharger and prior to the introduction into the cylinder, thereby lowering NOX emissions. 202 ALTERNATIVE FUELS: Substitutes for oil-derived and fossil-fuel derived fuels, including but not limited to biodiesel, propane, ethanol or methanol. 202 203 COGENERATION UNIT: A stationary RICE unit that burns fuel to simultaneously produce electricity and heat in a single thermodynamic process and is usually located in close proximity to the equipment requiring the heat energy. 204 COMMISSIONING PERIOD: The final phase of the stationary RICE construction process during which all mechanical, electrical, and control systems for the RICE and all related equipment are checked, and all performance measures specified in the purchase agreement are confirmed. For the purposes of this rule, a stationary RICE may not be used for its intended purpose or any other beneficial use during the commissioning period. If a non-emergency engine subject to this rule is also subject to a condition in a Maricopa County Air Quality Permit limiting total hours of operation, the hours of operation during the commissioning period shall be included when determining compliance with the permitted limit on total hours of operation. 85 203 205 COMPRESSION-IGNITION ENGINE: A stationary RICE with operating characteristics wherein the principal mechanism of igniting the fuel and air mixture in the cylinders is the compression of air in the cylinder until it is so hot that any fuel injected into the air or mixed with the air ignites. In this type of engine, a separate ignition source, such as a spark plug, is not used. 204 DIESEL ENGINE: A type of compression-ignition engine. 205 206 EMERGENCY ENGINE: A stationary RICE whose sole function is to provide back-up power when electric power from the local utility is interrupted or when operated solely for any of the reasons listed in Section 104 of this rule. An emergency engine, for the purposes of this rule, shall not be used to supply standby power due to a voluntary reduction in power by a utility or power company, supply power for distribution or sale to the grid, or supply power at a source in order to avoid peak demand charges or high electric energy prices during on-peak price periods and shall not exceed 500 hours of operation per calendar year including the 100 hours listed in Section 104.5 of this rule. A stationary RICE that meets all of the following criteria: 206.1 Is operated solely for any of the reasons listed in Section 104 of this rule; 206.2 Does not exceed 500 hours of operation per any twelve consecutive months, including the 100 hours per calendar year listed in Section 104.5 of this rule and including any hours of operation that occur during the commissioning period; and 206.3 Is not operated to supply standby power due to a voluntary reduction in power by a utility or power company, or to supply power for distribution or sale to the grid, or to supply power at a source in order to avoid peak demand charges or high electric energy prices during on-peak price periods. 206 ENGINE FAMILY: A group of stationary RICE with similar design features such as fuel type, cooling medium, method of air aspiration, combustion chamber design including cylinder bore and stroke, exhaust after treatment (if any), method of fuel admission, and method of control. These engines are also expected to have similar emission and operating characteristics throughout their useful lives. 207 EQUIVALENT REPLACEMENT ENGINE: A stationary RICE that is substituted for another stationary RICE that is intended to perform the same or similar function as the original stationary RICE and where all of the following conditions exist: 207.1 The equivalent replacement engine results in equal or lower air contaminant emissions than the original stationary RICE; and 207.2 The equivalent replacement engine meets the emission control technology standards contained in Section 304 of this rule; and 207.3 The rated bhp of the equivalent replacement engine does not exceed the rated bhp of the original stationary RICE (or sum of original stationary RICE) by more than 20 percent, for the purpose of this rule. For every percentage point increase of the rated bhp, there shall be an associated decrease in emissions of nitrogen oxides, expressed as a mass per unit time, equal to or exceeding two percentage points. 86 207 GASOLINE: Any fuel sold in any State for use in motor vehicles and motor vehicle engines, or nonroad or stationary engines, and commonly or commercially known or sold as gasoline. 208 IDENTICAL REPLACEMENT ENGINE: A stationary RICE that is substituted for another stationary RICE that is intended to perform the same or similar function as the original stationary RICE and where all of the following conditions exist: 208.1 The identical replacement engine results in equal or lower air contaminant emissions than the original stationary RICE; and 208.2 The identical replacement engine meets the emission control technology standards contained in Section 304 of this rule; and 208.3 The identical replacement engine has the same manufacturer type, model number, and manufacturer’s rated bhp as the original stationary RICE. 209 LEAN-BURN ENGINE: A spark-ignition engine with an air-to-fuel operating range that has more air present than is needed to burn the fuel present and cannot be adjusted to operate with an exhaust oxygen concentration of less than or equal to 2%. 210 LIQUEFIED PETROLEUM GAS (LPG): Any liquefied hydrocarbon gas obtained as a by-product in petroleum refining or natural gas production. 210 211 LOCATION: Any single site at a building, structure, facility or installation. 212 LOW SULFUR OIL: Fuel oil containing less than or equal to 0.05% sulfur by weight. 213 NATURAL GAS: A naturally occurring mixture of hydrocarbon and non-hydrocarbon gases found in geologic formations beneath the Earth’s surface, of which the principal constituent is methane. 211 214 NON-EMERGENCY ENGINE: A stationary RICE that is dedicated to a process or processes for the purpose of supplying primary mechanical or electrical power not an emergency engine. 212 NONROAD INTERNAL COMBUSTION (IC) ENGINE: 212.1 Equipment that meets the following requirements are nonroad IC engines: a. An internal combustion engine that is (or will be) used in or on a piece of equipment that is self-propelled or serves a dual purpose by both propelling itself and performing another function (such as garden tractors, off-highway mobile cranes, and bulldozers); or b. An internal combustion engine that is (or will be) used in or on a piece of equipment that is intended to be propelled while performing its function (such as lawnmowers and string trimmers); or c. An internal combustion engine that by itself or in or on a piece of equipment is portable or transportable, meaning designed to be and capable of being carried 87 or moved from one location to another. Indicia of transportability include but are not limited to, wheels, skids, carrying handles, dollies, trailers, or platforms. 212.2 The following are not nonroad IC engines: a. An engine used to propel a motor vehicle, an aircraft, or equipment used solely for competition; or b. An engine regulated by a federal New Source Performance Standard promulgated under Section 111 of the Clean Air Act; or c. An engine otherwise included in Section 212.1(c) of this rule that remains or will remain at a location for more than 12 consecutive months or a shorter period of time for an engine located at a seasonal source. A location is any single site at a building, structure, facility, or installation. Any engine (or engines) that replace(s) an engine at a location and that is intended to perform the same or similar function as the engine replaced will be included in calculating the consecutive time period. An engine located at a seasonal source is an engine that remains at a seasonal source during the full annual operating period of the seasonal source. A seasonal source is a stationary source that remains in a single location on a permanent basis (i.e. at least two years) and that operates at that single location approximately three months (or more) each year. This paragraph does not apply to an engine after the engine is removed from the location. 213 215 PARTS(S) PER MILLION, DRY BY VOLUME DRY (PPMDVD): A unit of proportion used to express concentration that is corrected to a dry basis. A unit of proportion equal to 10-6 that is measured on a dry basis (minus water) at 15% oxygen. 214 216 RATED BRAKE HORSEPOWER (RATED BHP): The maximum brake horsepower (bhp) specified by the engine manufacturer for the engine application, usually listed on the nameplate of the engine. If the engine has been altered so that the maximum brake horsepower is different than the rated brake horsepower on the nameplate, then the maximum brake horsepower shall be considered the rated brake horsepower. 217 RECONSTRUCTED: Repairs, changes, or improvements to a stationary RICE where the fixed capital cost of the new and refurbished engine components exceeds 75% of the fixed capital cost of purchasing an entirely new engine with the same brake horsepower rating; or construction of an engine on a previously used engine block if the engine is constructed using all new components except for the engine block. For the purposes of this rule, the cost of installing emission controls (such as a diesel particulate filter, a three-way catalyst, or a selective catalytic reduction system) is not included when determining whether or not an engine has been reconstructed. 215 218 RICH-BURN ENGINE: A spark-ignition engine that is not a lean-burn engine. 216 219 SPARK-IGNITION ENGINE: A stationary RICE wherein the fuel is usually mixed with intake air before introduction into the combustion chamber resulting in a relatively homogeneous air/fuel mixture in the combustion chamber, at which time a spark plug, or other device, then ignites the air/fuel mixture. 88 217 220 STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINE (RICE): A reciprocating, piston-driven internal combustion engine that is operated or intended to be operated at one specific location for more than 12 consecutive months or that is attached to a foundation at the location. An engine that replaces an engine at a location and is intended to perform the same or similar function as the engine being replaced will be included in calculating the consecutive time period. A stationary RICE is not a nonroad engine. 218 221 SULFUR OXIDES (SOX): Oxides of sulfur calculated as equivalent sulfur dioxide. 219 222 ULTRA LOW SULFUR OIL DIESEL: Fuel oil containing less than or equal to 0.0015% sulfur by weight. 220 223 WASTE DERIVED FUEL GAS: A gaseous fuel that is generated from the biodegradation of solid or liquid waste including, but not limited to, digester gas and landfill gas. SECTION 300 – STANDARDS: 301 LIMITATIONS FOR STATIONARY RICE – FUEL REQUIREMENTS: An owner or operator of an engine a stationary RICE that meets the criteria listed in Section 102 of this rule shall comply with either one of the following: 301.1 Use any fuel that contains no more than 0.0015% sulfur by weight, alone or in combination with other fuels. Use ultra low sulfur oil, except as provided in Sections 301.1a or 301.1b of this rule. a. Engines that are not subject to the 40 CFR 60 Subpart IIII or 40 CFR 63 Subpart ZZZZ may use existing low sulfur oil purchased (or otherwise obtained) prior to November 2, 2016 until depleted. b. Engines that are subject to 40 CFR 60 Subpart IIII or 40 CFR 63 Subpart ZZZZ must also comply with the fuel requirements in the applicable subpart. 301.2 Use any waste derived fuel gas that contains no more than 0.08% sulfur by weight, alone or in combination with other fuels. 301.3 Use gasoline that meets the sulfur standard of 80 ppm as a per-gallon cap. 301.4 Use natural gas, liquefied petroleum gas (LPG), or any alternative fuel that contains no more than 0.05% sulfur by weight, alone or in combination with other fuels. 302 GOOD COMBUSTION PRACTICES/TUNING PROCEDURE MAINTENANCE REQUIREMENTS FOR STATIONARY RICE: An owner or operator of an engine a stationary RICE that meets the criteria listed in Section 102 of this rule shall conduct preventative maintenance or tuning procedures as recommended by the engine manufacturer maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the maintenance schedule provided by the manufacturer’s authorized service provider to ensure good combustion practices to minimize NOX emissions. A handheld monitor may be used if so desired by the owner or operator for measurement of NOX and CO concentrations in the effluent stream after each adjustment is made; this may assist in determining that the proper adjustment has been made to minimize NOX and CO emissions. A handheld monitor may be used by the Control Officer to determine 89 compliance with this section. Alternatively, the owner or operator shall conduct preventative maintenance according to the following schedule, including include all of the following in the tuning procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine:. 302.1 Lubricating Oil and Filter: Change once every three months or after no more than 300 hours of operation, whichever occurs last. 302.2 Inlet Air Filter: Clean once every three months or after no more than 300 hours of operation and replace every 1,000 hours of operation or every year, whichever occurs last. 302.3 Fuel Filter: Clean once every year or replace (if cartridge type) once every 1,000 hours of operation, whichever occurs last. 302.4 Check and adjust the following once every year or after no more than 1,000 hours of operation, whichever occurs last: a. Intake and exhaust valves b. Spark plugs (if so equipped) c. Spark timing and dwell or fuel injection timing (if adjustable), and d. Carburetor mixture (if adjustable). 302.5 Spark Plugs and Ignition Points: Replace after 3,000 hours of operation or every year whichever occurs last 302.6 Coolant: Change after 3,000 hours of operation or every year whichever occurs last. 302.7 Exhaust System: Check for leaks and/or restrictions after 3,000 hours of operation or every year whichever occurs last. 302.1 The following maintenance procedures shall be completed no less frequently than every 300 hours of operation (for engines that operate 300 hours per year or more) or at least once every 12 months (for engines that operate less than 300 hours per year): a. Clean the inlet air filter (if so equipped); b. Change oil filter; and c. Change the lubricating oil or conduct an oil analysis to determine Total Base Number, viscosity, and percent water content. The lubricating oil must be replaced within 2 business days after the analytical results are received if any of the following condemning limits are exceeded: (i) Total Base Number is less than 30% of the Total Base Number of the oil when new; (ii) Viscosity of the oil has changed by more than 20 percent from the viscosity of the oil when new; or (iii) Percent water content (by volume) is greater than 0.5. 302.2 The following maintenance procedures shall be completed no less frequently than every 1,000 hours of operation (for engines that operate 1,000 hours per year or 90 more) or at least once every 12 months (for engines that operate less than 1,000 hours per year): a. Replace the inlet air filter; b. Clean all fuel filters (except cartridge type fuel filters); c. Replace cartridge type fuel filters; d. Check and adjust the intake and exhaust valves; e. Check and adjust the spark plugs (if so equipped); f. Check and adjust the spark timing and dwell or fuel injection timing (if adjustable); and g. Check and adjust the carburetor mixture (if adjustable). 302.3 The following maintenance procedures shall be completed no less frequently than every 3,000 hours of operation (for engines that operate 3,000 hours per year or more) or at least once every 12 months (for engines that operate less than 3,000 hours per year): a. Replace spark plugs and ignition points (if so equipped); b. Change coolant (if so equipped); and c. Check the exhaust system and repair all leaks and/or restrictions. 303 LIMITATIONS FOR STATIONARY RICE – OPACITY: An owner or operator of an engine a stationary RICE that meets the criteria in Section 102 of this rule shall not discharge into the ambient air from any such engine any air contaminant, other than uncombined water, in excess of 20% opacity. 304 LIMITATIONS FOR NON-EMERGENCY ENGINES 250 RATED BHP OR GREATER: In addition to meeting the standards in Sections 301, 302 and 303 of this rule, an owner or operator of a non-emergency engine that meets the criteria in Section 102 of this rule shall comply with Sections 304.1 or 304.2 of this rule. 304.1 Engine Requirements for Non-Emergency Engines Compression-Ignition Engines That Are Not Located At A Major Source of NOX: The emissions in parts per million by dry volume (ppmdv) or grams per bhp (g/bhp) from the non- emergency engines shall comply with either Table 1 or Table 2 of this rule. An owner or operator of a non-emergency compression-ignition engine that is rated above 250 bhp and is not located at a major source of NOX shall comply with the engine requirements in Table 324-1, as applicable, depending on the date the engine was manufactured or reconstructed (whichever occurred later) and the rated brake horsepower of the engine: 91 TABLE 324-1 COMPRESSION-IGNITION ENGINES MANUFACTURED OR MODIFIED RECONSTRUCTED RATED BHP ENGINE REQUIREMENTS* 770 ppmvdv or 10 g/bhp-hr. NOX or turbocharger with aftercooler/intercooler or Prior to October 22, 2003 250-399 4-degree injection timing retard delay 550 ppmvdv or 7.2 g/bhp-hr. NOX or turbocharger with 400 plus aftercooler/intercooler or Prior to October 22, 2003 More than 399 4-degree injection timing retard delay 530 ppmvdv or 6.9 g/bhp-hr. NOX; or turbocharger with aftercooler/intercooler or 4-degree injection timing retard; On or after October 22, 2003 but >250 1,000 ppmvdv CO; prior to July 11, 2005 More than 250 0.40 g/bhp-hr PM * ppmvd emission standards are corrected to 15% oxygen. 304.2 Requirements for Non-Emergency Spark-Ignition Engines That Are Not Located At A Major Source of NOX: An owner or operator of a non-emergency spark-ignition engine that is rated above 250 bhp and is not located at a major source of NOX shall comply with the engine requirements in Table 324-2, as applicable, depending on the date the engine was manufactured or reconstructed (whichever occurred later) and whether it is a lean-burn or rich-burn engine: TABLE 324-2 SPARK-IGNITION ENGINES LEAN-BURN ENGINES VOLATILE MANUFACTURED OXIDES OF ORGANIC CARBON OR MODIFIED RATED NITROGEN COMPOUND MONOXIDE RECONSTRUCTED BHP (NOX**) (VOC**) (CO**) 280 ppmvdv or 4.0 g/bhp- hr 800 ppmvdv or 5.0 4,500 ppmvdv Prior to October 22, or three-way g/bhp-hr or three-way 2003 >250 catalyst* or three-way catalyst* catalyst* On or after October 22, 110 ppmvdv 800 ppmdv or 5.0 2003 but prior to June or 1.5 g/bhp- g/bhp-hr 12, 2006 >250 hr Not Applicable 4,500 ppmvdv RICH-BURN ENGINES 92 VOLATILE MANUFACTURED OXIDES OF ORGANIC CARBON OR MODIFIED RATED NITROGEN COMPOUND MONOXIDE RECONSTRUCTED BHP (NOX**) (VOC**) (CO**) 280 ppmvdv or 4.0 g/bhp- 800 ppmvdv or 5.0 4,500 ppmvdv Prior to October 22, hr or three- g/bhp-hr or three-way or three-way 2003 >250 way catalyst* catalyst* catalyst* 20 ppmvdv or 800 ppmdv or 5.0 On or after October 22, 0.30 g/bhp-hr g/bhp-hr or three-way 4,500 ppmvdv 2003 but prior to June or three-way catalyst* or three-way 12, 2006 >250 catalyst* Not Applicable catalyst* * The three-way catalyst shall provide a minimum of 80% control efficiency for NOX and CO for those engines fueled with natural gas, propane or gasoline. In addition, the three-way catalyst shall also provide a minimum of at least 50% control efficiency for VOC for those engines fueled by gasoline. ** ppmvd emission standards are corrected to 15% oxygen. 304.3 Emission Limits for Non-Emergency Engines That Are Located At A Major Source of NOX: An owner or operator of a non-emergency engine that is rated above 50 bhp and is located at a major source of NOX shall comply with the engine requirements in Table 324-3, as applicable, depending on the engine type: TABLE 324-3 ENGINE TYPE NOX* VOC* CO* PM 110 ppmvd or 800 ppmvd or Not Spark-Ignition Lean-Burn 1.5 g/bhp-hr 5.0 g/bhp-hr 4,500 ppmvd Applicable 20 ppmvd or 800 ppmvd or Not Spark-Ignition Rich-Burn 0.30 g/bhp-hr 5.0 g/bhp-hr 4,500 ppmvd Applicable 530 ppmvd or Not Compression-Ignition 6.9 g/bhp-hr Applicable 1,000 ppmvd 0.40 g/bhp-hr * ppmvd emission standards are corrected to 15% oxygen. 304.2 Federal Standards of Performance for Non-Emergency Engines: An owner or operator of an engine listed in Sections 304.2(a) or (b) of this rule shall comply with the federal standards of performance for compression-ignition engines set forth in 40 CFR Part 60, Subpart IIII or spark-ignition engines set forth in 40 CFR Part 60, Subpart JJJJ and in all accompanying appendices as incorporated by reference in Rule 360 (New Source Performance Standards) of these rules. Whenever more than one provision in this rule applies to such engine or whenever a provision in this rule and a pr7ovision in the federal standards apply to such engine, the provision or combination of provisions resulting in the lowest rate of emissions shall apply, unless otherwise specifically exempted or designated. a. 40 CFR Part 60, Subpart IIII applies to all of the following non-emergency compression-ignition engines: 93 (1) Any stationary compression-ignition IC engine that was ordered after July 11, 2005 and manufactured after April 1, 2006. (2) Any stationary compression-ignition IC engine that was modified or reconstructed after July 11, 2005. b. 40 CFR Part 60, Subpart JJJJ applies to the following non-emergency spark- ignition engine: (1) Any stationary spark-ignition engine that was ordered after June 12, 2006 and manufactured on or after: (a) July 1, 2007 for engines with a rated bhp greater than or equal to 500 (except lean burn engines with a rated bhp greater than or equal to 500 and less than 1,350) (b) January 1, 2008 for lean burn engines with a rated bhp greater than or equal to 500 and less than 1,350 (c) July 1, 2008 for engines with a rated bhp less than 500. (2) Any stationary spark-ignition engine that was modified or reconstructed after June 12, 2006. 305 EFFICIENCY ALLOWANCE: Each emission limit expressed in Tables 324-1 or 324-2 of this rule may be multiplied by X, where X equals the engine efficiency (E) divided by a reference efficiency of 30 percent. Engine efficiency shall be determined by one of the following methods whichever is higher: a. E = (Engine Output) X (100) ÷ (Energy Input) where Energy Input is determined by a fuel measuring device accurate to +/- 5 % and is based upon the higher heating value (HHV) of the fuel. Percent efficiency (E) shall be averaged over 15 consecutive minutes and measured at peak load for the applicable engine. b. E = (Manufacturers Rated Efficiency [Continuous] at (LHV) X (LHV) ÷ (HHV) where LHV = the lower heating value of the fuel Engine efficiency (E) shall not be less than 30 percent; an engine with an efficiency lower than 30 percent shall be assigned an efficiency of 30 percent for the purposes of this rule. 306 305 EQUIVALENT REPLACEMENT ENGINE OR IDENTICAL REPLACEMENT ENGINE: An equivalent replacement engine or an identical replacement engine shall be treated as the original stationary RICE that it replaces for the purposes of compliance with this rule. 307 MODIFICATION TO A STATIONARY RICE: If a modification, including the contractual obligation to undertake and complete an order for an engine, is made to a stationary RICE, then such engine shall comply with all applicable provisions of this rule. The date of the modification shall be the trigger for when the modification is subject to the provisions of Section 304 of this rule. Whenever a provision in this rule and a provision in Section 304 of this rule apply to such engine, the provision or combination of provisions resulting in the lowest rate of emissions shall apply, unless otherwise specifically exempted or designated. 94 308 306 NON-RESETTING TOTALIZING HOUR METER: The owner or operator of a stationary RICE, subject to any provision of this rule, except for those engines being removed from service under Section 401 of this rule, shall install, and operate, and maintain a non-resetting totalizing hour meter. If the non-resetting totalizing hour meter is found to be malfunctioning, operation of the engine shall cease until corrective action(s) can be implemented or the function of the meter is restored the owner or operator shall: 306.1 Record hours of operation daily until the function of the hour meter is restored; and 306.2 Restore the function of the hour meter within two weeks. Or, if it is not possible to restore the function of the hour meter within two weeks, the owner or operator shall notify the Control Officer in writing and provide a schedule for restoration of the function of the hour meter. SECTION 400 – ADMINISTRATIVE REQUIREMENTS 401 COMPLIANCE SCHEDULE-STATIONARY RICE BEING REMOVED FROM SERVICE: If a stationary RICE must be removed from service because such engine does not comply with the emission limits listed in Section 300 of this rule, then the stationary RICE shall be removed from service no later than November 2, 2017 [insert date one year after rule adoption]. The stationary RICE that replaces such engine shall comply with all applicable provisions of this rule and shall comply with Section 304 of this rule upon installation. 402 COMPLIANCE SCHEDULE-NON-RESETTING TOTALIZING HOUR METER: The owner or operator of a stationary RICE that is not equipped with a non- resetting totalizing hour meter on [insert date of rule adoption], subject to any provision of this rule, except for those engines and is not being removed from service under Section 401 of this rule, shall install, and operate, and maintain a non-resetting totalizing hour meter on each such engine no later than November 2, 2017 [insert date one year after rule adoption]. 403 COMPLIANCE SCHEDULE-ENGINES AT A SOURCE THAT BECOMES A MAJOR SOURCE: If a non-emergency engine is located at a source that becomes a major source of nitrogen oxides after [insert date of rule adoption], the owner or operator shall demonstrate compliance with the emission limits in Table 324-3 within one year after the source becomes a major source of nitrogen oxides. SECTION 500 – MONITORING AND RECORDS 501 COMPLIANCE DETERMINATION: 501.1 Stationary RICE Non-Emergency Engines That Are Not Located At A Major Source of NOX: An owner or operator of a stationary RICE non-emergency engine which is subject to the requirements in Section 304.1 or 304.2 of this rule shall demonstrate compliance with all of the using one of the following methods, as applicable: a. With Section 300 of this rule, by recordkeeping according to Section 502 of this rule. Emission testing using the applicable test methods listed in Section 503 of this rule shall be performed upon the request of the Control Officer. Provide 95 documentation that the stationary RICE is certified by the manufacturer to comply with emission limits in 40 CFR 60 Subpart IIII or 40 CFR 60 Subpart JJJJ that are more stringent than the applicable emission limits in Table 324-1 or 324-2 of this rule, and provide documentation that the engine is installed, operated, and maintained in accordance with the manufacturer's specifications. b. With Section 304.2 of this rule, by one of the following: Conduct a performance test in accordance with Section 501.4 of this rule at least once every 5 years. The performance test shall demonstrate compliance with one of the following requirements: (1) A statement from the manufacturer that the engine meets the most stringent emissions standards found in this rule or 40 CFR Parts 89, 90, and 1039 applicable to the engine and its model year at the time of manufacture. The applicable emission limits in units of grams per brake horsepower-hour (g/bhp-hr); or (2) Emission testing using the applicable test methods listed in Section 503 of this rule shall be performed upon the request of the Control Officer. The applicable emission limits in units of ppmvd; or (3) The three-way catalyst provides a minimum of 80% control efficiency for NOX and CO for engines fueled with natural gas, propane or gasoline, and the three-way catalyst also provides a minimum of 50% control efficiency for VOC for engines fueled by gasoline. c. With 40 CFR Part 60.4213, for a stationary RICE with a displacement of greater than or equal to 30 liters per cylinder. Provide documentation that the non- emergency compression-ignition engine was manufactured or reconstructed (whichever occurred later) prior to October 22, 2003 and provide documentation that the non-emergency compression-ignition engine is equipped with a turbocharger with an aftercooler/intercooler. d. Provide documentation that the non-emergency compression-ignition engine was manufactured or reconstructed (whichever occurred later) prior to October 22, 2003 and: (1) Provide documentation that the injection timing has been set at 4 degrees below the factory setting for the engine. Written verification of the factory set timing, along with documentation that the engine timing has been delayed by 4 degrees must be submitted; or (2) Provide documentation that the injection timing has been set at 4 degrees below the manufacturer's standard timing of the engine. Written verification of the manufacturer's standard timing of the engine prior to tuning for NOX control, along with documentation that the timing has been delayed by 4 degrees must be submitted; or (3) Provide documentation that the injection timing has been set at 16 degrees below top dead center or less (if information regarding the manufacturer's standard timing or factory set timing is not available). 96 501.2 Non-Emergency Engines That Are Located At A Major Source of Nitrogen Oxides: An owner or operator of a non-emergency engine which is subject to emission limits in Section 304.3 of this rule shall demonstrate compliance by conducting a performance test in accordance with Section 501.4 of this rule at least once every 2 years. The performance test shall demonstrate compliance with the applicable emission limits in units of grams per brake horsepower-hour (g/bhp-hr) or ppmvd. A statement from the manufacturer that the engine meets the most stringent emissions standards found in this rule or 40 CFR Parts 89, 90, and 1039 applicable to the engine and its model year at the time of manufacture. (2)Emission testing using the applicable test methods listed in Section 503 of this rule shall be performed upon the request of the Control With 40 CFR Part 60.4213, for an engine family with a displacement of greater than or equal to 30 liters per cylinder. 501.3 Representative Performance Testing: An owner or operator may demonstrate compliance with the applicable emission limits or control efficiency requirements in Table 324-1, Table 324-2, or Table 324-3 of this rule by conducting representative performance testing in accordance with Section 501.4 of this rule, provided all of the following requirements are satisfied: a. The engines are located at the same stationary source; b. The engines were produced by the same manufacturer, have the same model number or other manufacturer's designation in common, and have the same rated capacity and operating specifications; c. The engines are operated and maintained in a similar manner; d. At least one engine or one third of the engines in the specified group, whichever is greater, are tested each time a performance test is required; e. Each time a performance test is required, different engines are tested so that all engines in the specified group are tested before any engines in the representative group are retested; and f. If emissions from any engine in the specified group exceed an applicable emission limit, or if the control efficiency for any pollutant controlled by a three- way catalyst is lower than the required control efficiency, the owner or operator shall demonstrate that each engine in the specified group is in compliance with the applicable limits by conducting a performance test on each engine in the specified group. 501.4 Performance Test Conditions: Performance tests shall be conducted using the test methods listed in Section 503 of this rule. Testing for stationary RICE shall be completed at either the maximum operating load or no less than 80% of the rated bhp. If the owner or operator of an engine demonstrates to the Control Officer that the engine cannot operate at these conditions, then emissions source testing shall be performed at the highest achievable continuous rated bhp or under the typical duty cycle or typical operational mode of the engine. The result of the performance test 97 shall be the arithmetic mean of the results of three test runs. Each test run shall have a minimum sample time of one hour. 501.3 501.5 Ultra Low Sulfur Diesel Fuel-Sulfur Verification: If the Control Officer requests documentation of the sulfur content of the fuel to demonstrate the 0.0015% limit, the The owner or operator of an engine fueled with gasoline shall submit documentation that gasoline was purchased within the United States. The owner or operator of an engine fueled with diesel, natural gas, LPG, or an alternative fuel shall submit one of the following documents listing the accurate sulfur content of the fuel based on enforceable test methods as approved by the Administrator to determine the sulfur content: a. Fuel receipts, or b. Contract specifications, or c. Pipeline meter tickets, or d. Fuel supplier information, or e. Purchase records, or f. Test results of the fuel for sulfur content. The items listed above must provide accurate sulfur content values or be based on enforceable test methods as approved by the Administrator to determine the sulfur content. 501.4 501.6 Waste Derived Fuel Gas - Sulfur Verification: The owner or operator shall submit documentation of the concentration of the sulfur level content of the waste derived fuel gas to the Control Officer upon request. The sulfur content of gaseous fuels shall be determined by South Coast Air Quality Management District Method 307-91 Determination of Sulfur in a Gaseous Matrix. 501.5 Test Method Conditions: The owner or operator shall use the test methods listed in Section 503 of this rule to determine compliance with the limitations listed in Tables 1 or 2 of this rule. Testing for stationary RICE shall be completed under steady state conditions at either the maximum operating load or no less than 80% of the rated bhp. If the owner or operator of an engine demonstrates to the Control Officer that the engine cannot operate at these conditions, then emissions source testing shall be performed at the highest achievable continuous rated bhp or under the typical duty cycle or typical operational mode of the engine. 502 RECORDKEEPING/RECORDS RETENTION: The owner or operator of a stationary RICE subject to this rule shall comply with the following requirements and retain records for at least 5 years: 502.1 Records Required for a Stationary RICE List: An owner or operator of a stationary RICE, including emergency engines, non-emergency engines, and low usage non- emergency engines, shall keep a record that includes an initial one time entry that lists Maintain a list of stationary RICE that includes all of the following information for each stationary RICE: the particular engine combustion type (compression-ignition, or lean-burn spark-ignition, or rich burn, lean burn rich-burn spark-ignition); manufacturer; model designation, rated bhp, serial number, and where the the location of each engine is located on the site at the facility. If the equipment list associated with 98 the current permit includes all of the required information for each stationary RICE located at the facility, this requirement may be fulfilled by keeping a complete copy of the current permit, including the equipment list, in a readily accessible location at the facility where the engines are located, and by providing the equipment list to the Control Officer upon request. 502.2 Monthly Records Required for Non-Emergency Engines Operation Records: An owner or operator of a non-emergency engine stationary RICE shall maintain a monthly record for non-emergency engines which shall include records of the monthly and 12-month rolling total hours of operation for each stationary RICE. For emergency engines, the operation records shall also include: a. Hours of operation; and Monthly and annual hours of operation for reliability related activities such as engine readiness, calibration, or maintenance, or to prevent the occurrence of an unsafe condition during electrical system maintenance; and b. Type of fuel used, and The number of operating hours for emergency use and an explanation for the emergency use. c. Documentation verifying compliance with sulfur fuel content. 502.3 Annual Records Required for Non-Emergency Engines Maintenance Records: An owner or operator of a non-emergency engine stationary RICE shall maintain an annual record of the practices/procedures that are followed in order to comply with Section 302 (Good Combustion Practices/Tuning Procedures for Stationary RICE) of this rule records of all stationary RICE maintenance (including the date when maintenance was performed and the maintenance procedures that were performed). If an owner or operator of a non-emergency engine demonstrates compliance with the requirements in Section 304.1 of this rule using the method specified in Section 501.1(d) of this rule, the maintenance record shall include documentation of the injection timing setting each time maintenance is performed on the stationary RICE. In addition, one of the following documents shall be available at all times at the facility where the stationary RICE is located: a. The manufacturer’s written instructions for operation and maintenance of each stationary RICE; b. A written maintenance schedule provided by the manufacturer’s authorized service provider; or c. A written maintenance plan indicating which of the tuning procedures listed in Section 302 of this rule are applicable to each stationary RICE. 502.4 Fuel Records: Required for an Emergency Engine or a Low Usage Non-Emergency Engine An owner or operator of an emergency engine or a low usage non-emergency engine that meets the exemptions listed in Sections 104 and 105 of this rule shall keep an engine record that includes: a. Monthly rolling twelve month total of hours of operation, including hours of operation for testing, reliability and maintenance; and Maintain records of the type and amount of fuel purchased for use in the stationary RICE (e.g. receipts, pipeline tickets, or bills of lading); and 99 b. Fuel type and sulfur content of fuel; and Maintain records of the sulfur content of any fuel that is used in the stationary RICE, excluding gasoline. For gasoline, maintain records that the fuel was purchased in the United States. c. Explanation for the use of the engine if it is used as an emergency engine. 502.5 Manufacturer's Operation and Maintenance Instructions: An owner or operator of an engine that is subject to the requirements of Section 302 of this rule shall keep the manufacturer's written instructions for operation and maintenance of the engine available at the facility where the engine is located at all times. If the manufacturer's written instructions are not available, the owner or operator shall keep a preventative maintenance plan, indicating which procedures in Section 302 of this rule are appropriate to the engine, available at the facility where the engine is located at all times. 502.6 Nonroad Engine Records: An owner or operator of a nonroad engine shall maintain the following records for each non-road engine: a. Date that each engine is brought to the stationary source; and b. For engines located at a stationary source greater than 14 consecutive days: (1) Make, model, serial number, and rated capacity (bhp hours) of the engine; and (2) Date of each instance in which the engine is moved from its existing location, and the reason why the engine was moved; and (3) Fuel type and sulfur content of the fuel. 503 COMPLIANCE DETERMINATION-TEST METHODS INCORPORATED BY REFERENCE: The following test methods are approved for use for the purpose of determining compliance with this rule. The test methods are incorporated by reference in Rule 360 and Appendix G of the Maricopa County Air Pollution Control Regulations. Alternative test methods as approved by the Administrator or other EPA-approved test methods may be used upon written approval from the Control Officer. When more than one test method is permitted for the same determination, an exceedance under any method will constitute a violation. Copies of test methods referenced in this section are available at the Maricopa County Air Quality Department. 503.1 EPA Reference Methods 1 (“Sample and Velocity Traverses for Stationary Sources”) and 1A (“Sample and Velocity Traverses for Stationary Sources with Small Stacks or Ducts”) (40 CFR 60, Appendix A). 503.2 EPA Reference Methods 2 (“Determination of Stack Gas Velocity and Volumetric Flow Rate”), 2A (“Direct Measurement of Gas Volume Through Pipes and Small Ducts”), 2C (“Determination of Stack Gas Velocity and Volumetric Flow Rate in Small Stacks or Ducts”), and 2D (“Measurement of Gas Volumetric Flow Rates in Small Pipes and Ducts”) (40 CFR 60, Appendix A). 503.3 EPA Reference Methods 3 (“Gas Analysis for the Determination of Dry Molecular Weight”), 3A (“Determination of Oxygen and Carbon Dioxide Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure"), 3B (“Gas Analysis for the Determination of Emission Rate Correction Factor of or Excess 100 Air”), and 3C (“Determination of Carbon Dioxide, Methane, Nitrogen and Oxygen from Stationary Sources”) (40 CFR 60, Appendix A). 503.4 EPA Reference Method 4 (“Determination of Moisture Content in Stack Gases”) (40 CFR 60, Appendix A). 503.5 EPA Reference Method 5 (“Determination of Particulate Emissions from Stationary Sources”) (40 CFR 60, Appendix A) 503.6 EPA Reference Method 202 (“Determination of Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources”) (40 CFR 51, Appendix M). 503.7 EPA Reference Methods 7 (“Determination of Nitrogen Oxide Emissions from Stationary Sources”), 7A (“Determination of Nitrogen Oxide Emissions fromform Stationary Sources - Ion Chromatographic Method”), 7B (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Ultraviolet Spectrometry Spectrophotometry Method”), 7C (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Alkaline Permanganate/Colorimetric Method”), 7D (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Alkaline – -Permanganate/Ion Chromatographic Method”), and 7E (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Instrumental Analyzer Method“ Procedure”), (40 CFR 60, Appendix A). 503.8 EPA Reference Method 9 (“Visual Determination of the Opacity of Emissions from Stationary Sources”) (40 CFR 60, Appendix A). 503.9 EPA Reference Method 10 (“Determination of Carbon Monoxide from Stationary Sources”) (40 CFR 60, Appendix A). 503.10 EPA Reference Method 18 (“Measurement of Gaseous Organic Compound Emissions by Gas Chromatography”) (40 CFR 60, Appendix A). 503.11 EPA Reference Method 25A (“Determination of Total Gaseous Organic Concentration Using a Flame Ionization Analyzer”) (40 CFR 60, Appendix A). 503.12 ASTM D2622-98 D2622-05 (“Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry”). 503.13 ASTM D2880-96 Standard Specification for Gas Turbine Fuel Oils 503.14 503.13 ASTM D4294-02 or D4294-03 (“Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy-Dispersive X-Ray Fluoresence Spectroscopy Fluorescence Spectrometry”). 503.15 503.14 ASTM D5504-01 or D5504-08 (“Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence”). 504.16 503.15 South Coast Air Quality Management District Method 307-94 307-91 (“Determination of Sulfur in a Gaseous Matrix”), revised 1994. 101 Return to list of attachments MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III – CONTROL OF AIR CONTAMINANTS RULE 324 STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINES (RICE) INDEX SECTION 100 – GENERAL 101 PURPOSE 102 APPLICABILITY 103 EXEMPTIONS 104 PARTIAL EXEMPTIONS FOR EMERGENCY ENGINES 105 PARTIAL EXEMPTIONS FOR LOW USAGE NON-EMERGENCY ENGINES 106 PARTIAL EXEMPTION FOR NONROAD ENGINES 107 PARTIAL EXEMPTION FOR NON-EMERGENCY ENGINES THAT ARE LOCATED AT A MAJOR SOURCE OF NITROGEN OXIDES (NOX) 108 PARTIAL EXEMPTION FOR STATIONARY RICE THAT ARE LOCATED AT A NUCLEAR POWER PLANT SECTION 200 – DEFINITIONS 201 AFTERCOOLER/INTERCOOLER 202 ALTERNATIVE FUELS 203 COGENERATION UNIT 204 COMMISSIONING PERIOD 205 COMPRESSION-IGNITION ENGINE 206 EMERGENCY ENGINE 207 GASOLINE 208 IDENTICAL REPLACEMENT ENGINE 209 LEAN-BURN ENGINE 210 LIQUEFIED PETROLEUM GAS (LPG) 211 LOCATION 212 LOW SULFUR OIL 213 NATURAL GAS 214 NON-EMERGENCY ENGINE 215 PARTS PER MILLION BY VOLUME DRY (PPMVD) 102 216 RATED BRAKE HORSEPOWER (RATED BHP) 217 RECONSTRUCTED 218 RICH-BURN ENGINE 219 SPARK-IGNITION ENGINE 220 STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINE (RICE) 221 SULFUR OXIDES (SOX) 222 ULTRA LOW SULFUR OIL 223 WASTE DERIVED FUEL GAS SECTION 300 – STANDARDS 301 FUEL REQUIREMENTS 302 MAINTENANCE REQUIREMENTS 303 LIMITATIONS FOR STATIONARY RICE - OPACITY 304 LIMITATIONS FOR NON-EMERGENCY ENGINES 305 IDENTICAL REPLACEMENT ENGINE 306 NON-RESETTING TOTALIZING HOUR METER SECTION 400 – ADMINISTRATIVE REQUIREMENTS 401 COMPLIANCE SCHEDULE-STATIONARY RICE BEING REMOVED FROM SERVICE 402 COMPLIANCE SCHEDULE-NON-RESETTING TOTALIZING HOUR METER 403 COMPLIANCE SCHEDULE-ENGINES AT A SOURCE THAT BECOMES A MAJOR SOURCE SECTION 500 – MONITORING AND RECORDS 501 COMPLIANCE DETERMINATION 502 RECORDKEEPING/RECORDS RETENTION 503 COMPLIANCE DETERMINATION-TEST METHODS INCORPORATED BY REFERENCE 103 Adopted 10/22/2003; Revised 10/17/2007; Revised 11/02/2016; Revised MM/DD/YYYY MARICOPA COUNTY AIR POLLUTION CONTROL REGULATIONS REGULATION III – CONTROL OF AIR CONTAMINANTS RULE 324 STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINES (RICE) SECTION 100 – GENERAL 101 PURPOSE: To limit carbon monoxide (CO), nitrogen oxides (NOX), sulfur oxides (SOX), volatile organic compounds (VOCs), and particulate matter (PM) emissions from stationary reciprocating internal combustion engines (RICE). 102 APPLICABILITY: 102.1 This rule applies to: a. Any stationary RICE, including stationary RICE used in cogeneration, with a rated brake horsepower (rated bhp) of greater than 125, if the stationary RICE is not located at a major source of NOX emissions; b. Any stationary RICE, including stationary RICE used in cogeneration, with a rated bhp of more than 50 if the stationary RICE is not located at a major source of NOX emissions and the maximum aggregated rated bhp of all stationary RICE at the stationary source is more than 125 when all engines with a rated bhp of more than 50 are aggregated; c. Any stationary RICE, including stationary RICE used in cogeneration, with a rated brake horsepower (rated bhp) of greater than 50, if the stationary RICE is located at a major source of NOX emissions; and d. Any nonroad engine, with a rated bhp of greater than 125, that is located at a stationary source that emits or has the potential to emit any regulated air pollutant greater than the permitting thresholds defined in Rule 100 of these rules. For the purpose of this Rule, a nonroad engine is any internal combustion engine that by itself or in or on a piece of equipment is portable or transportable, meaning designed to be and capable of being carried or moved from one location to another. Indicia of transportability include but are not limited to, wheels, skids, carrying handles, dollies, trailers, or platforms. 102.2 NSPS: In addition to this rule, a stationary RICE may be subject to New Source Performance Standards (NSPS) in Rule 360 of these rules. 102.3 NESHAP: In addition to this rule, a stationary RICE may be subject to National Emission Standards for Hazardous Air Pollutants (NESHAP) in Rule 370 of these rules. 103 EXEMPTIONS: The following types of stationary RICE are exempt from all of the requirements of this rule but shall comply with Rule 300 (Visible Emissions) of these rules: 104 103.1 A stationary RICE used directly and exclusively for engine research including engine development, and subsequent engine performance verification for the purpose of either engine emission control techniques or engine efficiency improvements. 103.2 A non-emergency engine when it is operated by a manufacturer or distributor of such equipment for the purpose of performance verification and testing at the production facility. 103.3 A compressed gas stationary RICE used for solar testing and research programs. 103.4 A stationary RICE test stand used for evaluating engine performance. 104 PARTIAL EXEMPTIONS FOR EMERGENCY ENGINES: A stationary RICE operated as an emergency engine, as defined in this rule, for any of the following reasons shall be exempt from Sections 304, 501.1, 501.2, 501.3, and 501.4 of this rule when: 104.1 Used only for power when normal power service fails from the serving utility or if onsite electrical transmission or onsite power generation equipment fails. 104.2 Used only for the emergency pumping of water resulting from a flood, fire, lightning strikes, police action or for any other essential public services which affect public health and safety. 104.3 Used for lighting airport runways. 104.4 Used for sewage overflow mitigation and/or prevention. 104.5 Used for reliability-related activities such as engine readiness, calibration, or maintenance or to prevent the occurrence of an unsafe condition during electrical system maintenance, as long as the total number of hours of the operation for these purposes does not exceed 100 hours per calendar year per engine as evidenced by an installed non-resetting totalizing hour meter. For the purposes of this rule, hours of operation during the commissioning period do not count towards the 100 hour per calendar year limit on hours of operation for reliability-related activities. 104.6 Used as the non-emergency engine when the non-emergency engine has failed, but only for such time as is needed to repair the non-emergency engine. For the purposes of this exemption, if the non-emergency engine is not repaired and returned to service within 12 months, or if the emergency engine is used as the non-emergency engine for more than 50 hours, whichever occurs first, the emergency engine shall be reclassified as a non-emergency engine and shall comply with all requirements of this rule that are applicable to non-emergency engines. 104.7 Used to operate standby emergency water pumps for fire control that activate when sensors detect low water pressure. 105 PARTIAL EXEMPTIONS FOR LOW USAGE NON-EMERGENCY ENGINES: The following low usage non-emergency engines onsite and in use before [date of rule adoption] shall be exempt from Sections 304, 501.1, 501.2, 501.3, 501.4, and 502.6 of this rule: 105.1 Each engine with a rated bhp at or below 1000 that operates less than 200 hours per calendar year as evidenced by an installed non-resetting totalizing hour meter. 105 105.2 Each engine with a rated bhp above 1000 that operates less than 100 hours per calendar year as evidenced by an installed non-resetting totalizing hour meter. 106 PARTIAL EXEMPTION FOR NONROAD ENGINES: Each nonroad engine shall comply with Rule 300 of these rules and Section 502.6 of this rule, but shall be exempt from all other requirements of this rule. 107 PARTIAL EXEMPTION FOR NON-EMERGENCY ENGINES THAT ARE LOCATED AT A MAJOR SOURCE OF NOX: A non-emergency engine that is located at a major source of NOX shall not be required to comply with Section 501.2 of this rule during the five year period beginning on January 1st of the year in which the engine was manufactured, if the owner or operator provides documentation that the non-emergency engine is certified by the manufacturer to comply with emission limits in 40 CFR 60 subpart IIII or 40 CFR 60 subpart JJJJ that are more stringent than the applicable emission limit(s) in Table 324-3 of this rule, and provides documentation that the non-emergency engine is installed, operated, and maintained in accordance with the manufacturer's specifications. 108 PARTIAL EXEMPTION FOR STATIONARY RICE THAT ARE LOCATED AT A NUCLEAR POWER PLANT: A stationary RICE that is located at a nuclear power plant and is operated solely for the following reasons shall comply only with the provisions in Sections 301, 302, 306, 402, 501.5, 502.1, 502.3, 502.4, and 502.5 of this rule: 108.1 Used for safety reasons and for operational tests required by the Nuclear Regulatory Commission. 108.2 Used for power when normal power service fails from the serving utility or if onsite electrical transmission or onsite power generation equipment fails. 108.3 Used for the emergency pumping of water resulting from a flood, fire, lightning strikes, police action or for any other operation that is essential to public health and safety. 108.4 Used to initiate operation of onsite emergency power generation equipment. 108.5 Used for reliability-related activities such as engine readiness, calibration, or maintenance or to prevent the occurrence of an unsafe condition during electrical system maintenance. Hours of operation for reliability-related activities shall not exceed 100 hours per year unless the reliability-related activities are recommended or required by the federal, state, or local government and the owner or operator maintains records demonstrating that the reliability-related activities are recommended or required. SECTION 200 – DEFINITIONS: For the purpose of this rule, the following definitions shall apply, in addition to those definitions found in Rule 100 (General Provisions and Definitions) of these rules. In the event of any inconsistency between any of the Maricopa County Air Pollution Control Rules, the definitions in this rule take precedence. 201 AFTERCOOLER/INTERCOOLER: A system that cools the engine intake air or air/fuel mixture after the air exits the turbocharger and prior to the introduction into the cylinder, thereby lowering NOX emissions. 106 202 ALTERNATIVE FUELS: Substitutes for oil-derived and fossil-fuel derived fuels, including but not limited to biodiesel, propane, ethanol or methanol. 203 COGENERATION UNIT: A stationary RICE unit that burns fuel to simultaneously produce electricity and heat in a single thermodynamic process and is usually located in close proximity to the equipment requiring the heat energy. 204 COMMISSIONING PERIOD: The final phase of the stationary RICE construction process during which all mechanical, electrical, and control systems for the RICE and all related equipment are checked, and all performance measures specified in the purchase agreement are confirmed. For the purposes of this rule, a stationary RICE may not be used for its intended purpose or any other beneficial use during the commissioning period. If a non-emergency engine subject to this rule is also subject to a condition in a Maricopa County Air Quality Permit limiting total hours of operation, the hours of operation during the commissioning period shall be included when determining compliance with the permitted limit on total hours of operation. 205 COMPRESSION-IGNITION ENGINE: A stationary RICE with operating characteristics wherein the principal mechanism of igniting the fuel and air mixture in the cylinders is the compression of air in the cylinder until it is so hot that any fuel injected into the air or mixed with the air ignites. In this type of engine, a separate ignition source, such as a spark plug, is not used. 206 EMERGENCY ENGINE: A stationary RICE that meets all of the following criteria: 206.1 Is operated solely for any of the reasons listed in Section 104 of this rule; 206.2 Does not exceed 500 hours of operation per any twelve consecutive months, including the 100 hours per calendar year listed in Section 104.5 of this rule and including any hours of operation that occur during the commissioning period; and 206.3 Is not operated to supply standby power due to a voluntary reduction in power by a utility or power company, or to supply power for distribution or sale to the grid, or to supply power at a source in order to avoid peak demand charges or high electric energy prices during on-peak price periods. 207 GASOLINE: Any fuel sold in any State for use in motor vehicles and motor vehicle engines, or nonroad or stationary engines, and commonly or commercially known or sold as gasoline. 208 IDENTICAL REPLACEMENT ENGINE: A stationary RICE that is substituted for another stationary RICE that is intended to perform the same or similar function as the original stationary RICE and where all of the following conditions exist: 208.1 The identical replacement engine results in equal or lower air contaminant emissions than the original stationary RICE; and 208.2 The identical replacement engine meets the emission control technology standards contained in Section 304 of this rule; and 208.3 The identical replacement engine has the same manufacturer type, model number, and manufacturer’s rated bhp as the original stationary RICE. 107 209 LEAN-BURN ENGINE: A spark-ignition engine with an air-to-fuel operating range that has more air present than is needed to burn the fuel present and cannot be adjusted to operate with an exhaust oxygen concentration of less than or equal to 2%. 210 LIQUEFIED PETROLEUM GAS (LPG): Any liquefied hydrocarbon gas obtained as a by-product in petroleum refining or natural gas production. 211 LOCATION: Any single site at a building, structure, facility or installation. 212 LOW SULFUR OIL: Fuel oil containing less than or equal to 0.05% sulfur by weight. 213 NATURAL GAS: A naturally occurring mixture of hydrocarbon and non-hydrocarbon gases found in geologic formations beneath the Earth’s surface, of which the principal constituent is methane. 214 NON-EMERGENCY ENGINE: A stationary RICE that is not an emergency engine. 215 PARTS PER MILLION BY VOLUME DRY (PPMVD): A unit of proportion used to express concentration that is corrected to a dry basis. 216 RATED BRAKE HORSEPOWER (RATED BHP): The maximum brake horsepower (bhp) specified by the engine manufacturer for the engine application, usually listed on the nameplate of the engine. If the engine has been altered so that the maximum brake horsepower is different than the rated brake horsepower on the nameplate, then the maximum brake horsepower shall be considered the rated brake horsepower. 217 RECONSTRUCTED: Repairs, changes, or improvements to a stationary RICE where the fixed capital cost of the new and refurbished engine components exceeds 75% of the fixed capital cost of purchasing an entirely new engine with the same brake horsepower rating; or construction of an engine on a previously used engine block if the engine is constructed using all new components except for the engine block. For the purposes of this rule, the cost of installing emission controls (such as a diesel particulate filter, a three-way catalyst, or a selective catalytic reduction system) is not included when determining whether or not an engine has been reconstructed. 218 RICH-BURN ENGINE: A spark-ignition engine that is not a lean-burn engine. 219 SPARK-IGNITION ENGINE: A stationary RICE wherein the fuel is usually mixed with intake air before introduction into the combustion chamber resulting in a relatively homogeneous air/fuel mixture in the combustion chamber, at which time a spark plug, or other device, then ignites the air/fuel mixture. 220 STATIONARY RECIPROCATING INTERNAL COMBUSTION ENGINE (RICE): A reciprocating, piston-driven internal combustion engine that is operated or intended to be operated at one specific location for more than 12 consecutive months or that is attached to a foundation at the location. An engine that replaces an engine at a location and is intended to perform the same or similar function as the engine being replaced will be included in calculating the consecutive time period. A stationary RICE is not a nonroad engine. 108 221 SULFUR OXIDES (SOX): Oxides of sulfur calculated as equivalent sulfur dioxide. 222 ULTRA LOW SULFUR OIL: Fuel oil containing less than or equal to 0.0015% sulfur by weight. 223 WASTE DERIVED FUEL GAS: A gaseous fuel that is generated from the biodegradation of solid or liquid waste including, but not limited to, digester gas and landfill gas. SECTION 300 – STANDARDS: 301 FUEL REQUIREMENTS: An owner or operator of a stationary RICE that meets the criteria listed in Section 102 of this rule shall comply with one of the following: 301.1 Use ultra low sulfur oil, except as provided in Sections 301.1a or 301.1b of this rule. a. Engines that are not subject to the 40 CFR 60 Subpart IIII or 40 CFR 63 Subpart ZZZZ may use existing low sulfur oil purchased (or otherwise obtained) prior to November 2, 2016 until depleted. b. Engines that are subject to 40 CFR 60 Subpart IIII or 40 CFR 63 Subpart ZZZZ must also comply with the fuel requirements in the applicable subpart. 301.2 Use any waste derived fuel gas that contains no more than 0.08% sulfur by weight, alone or in combination with other fuels. 301.3 Use gasoline that meets the sulfur standard of 80 ppm as a per-gallon cap. 301.4 Use natural gas, liquefied petroleum gas (LPG), or any alternative fuel that contains no more than 0.05% sulfur by weight, alone or in combination with other fuels. 302 MAINTENANCE REQUIREMENTS: An owner or operator of a stationary RICE shall maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the maintenance schedule provided by the manufacturer’s authorized service provider. Alternatively, the owner or operator shall conduct preventative maintenance according to the following schedule, including all of the following tuning procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine. 302.1 The following maintenance procedures shall be completed no less frequently than every 300 hours of operation (for engines that operate 300 hours per year or more) or at least once every 12 months (for engines that operate less than 300 hours per year): a. Clean the inlet air filter (if so equipped); b. Change oil filter; and c. Change the lubricating oil or conduct an oil analysis to determine Total Base Number, viscosity, and percent water content. The lubricating oil must be replaced within 2 business days after the analytical results are received if any of the following condemning limits are exceeded: (i) Total Base Number is less than 30% of the Total Base Number of the oil when new; 109 (ii) Viscosity of the oil has changed by more than 20 percent from the viscosity of the oil when new; or (iii) Percent water content (by volume) is greater than 0.5. 302.2 The following maintenance procedures shall be completed no less frequently than every 1,000 hours of operation (for engines that operate 1,000 hours per year or more) or at least once every 12 months (for engines that operate less than 1,000 hours per year): a. Replace the inlet air filter; b. Clean all fuel filters (except cartridge type fuel filters); c. Replace cartridge type fuel filters; d. Check and adjust the intake and exhaust valves; e. Check and adjust the spark plugs (if so equipped); f. Check and adjust the spark timing and dwell or fuel injection timing (if adjustable); and g. Check and adjust the carburetor mixture (if adjustable). 302.3 The following maintenance procedures shall be completed no less frequently than every 3,000 hours of operation (for engines that operate 3,000 hours per year or more) or at least once every 12 months (for engines that operate less than 3,000 hours per year): a. Replace spark plugs and ignition points (if so equipped); b. Change coolant (if so equipped); and c. Check the exhaust system and repair all leaks and/or restrictions. 303 LIMITATIONS FOR STATIONARY RICE – OPACITY: An owner or operator of a stationary RICE shall not discharge into the ambient air from any such engine any air contaminant, other than uncombined water, in excess of 20% opacity. 304 LIMITATIONS FOR NON-EMERGENCY ENGINES: 304.1 Requirements for Non-Emergency Compression-Ignition Engines That Are Not Located At A Major Source of NOX: An owner or operator of a non- emergency compression-ignition engine that is rated above 250 bhp and is not located at a major source of NOX shall comply with the engine requirements in Table 324-1, as applicable, depending on the date the engine was manufactured or reconstructed (whichever occurred later) and the rated brake horsepower of the engine: TABLE 324-1 MANUFACTURED OR RECONSTRUCTED RATED BHP ENGINE REQUIREMENTS* 770 ppmvd or 10 g/bhp-hr NOX or turbocharger with Prior to October 22, 2003 250-399 aftercooler/intercooler or 110 TABLE 324-1 MANUFACTURED OR RECONSTRUCTED RATED BHP ENGINE REQUIREMENTS* 4-degree injection timing delay 550 ppmvd or 7.2 g/bhp-hr NOX or turbocharger with aftercooler/intercooler or Prior to October 22, 2003 More than 399 4-degree injection timing delay 530 ppmvd or 6.9 g/bhp-hr NOX; 1,000 ppmvd CO; On or after October 22, 2003 More than 250 0.40 g/bhp-hr PM * ppmvd emission standards are corrected to 15% oxygen. 304.2 Requirements for Non-Emergency Spark-Ignition Engines That Are Not Located At A Major Source of NOX: An owner or operator of a non-emergency spark-ignition engine that is rated above 250 bhp and is not located at a major source of NOX shall comply with the engine requirements in Table 324-2, as applicable, depending on the date the engine was manufactured or reconstructed (whichever occurred later) and whether it is a lean-burn or rich-burn engine: TABLE 324-2 LEAN-BURN ENGINES MANUFACTURED OR RECONSTRUCTED NOX** VOC** CO** 280 ppmvd or 4.0 800 ppmvd or 5.0 4,500 ppmvd Prior to October 22, g/bhp-hr g/bhp-hr or three-way 2003 or three-way catalyst* or three-way catalyst* catalyst* On or after October 22, 110 ppmvd or 1.5 2003 g/bhp-hr Not Applicable 4,500 ppmvd RICH-BURN ENGINES MANUFACTURED OR RECONSTRUCTED NOX** VOC** CO** 280 ppmvd or 4.0 800 ppmvd or 5.0 Prior to October 22, g/bhp-hr or three-way g/bhp-hr or three- 4,500 ppmvd or 2003 catalyst* way catalyst* three-way catalyst* On or after October 22, 20 ppmvd or 0.30 2003 g/bhp-hr Not Applicable 4,500 ppmvd * The three-way catalyst shall provide a minimum of 80% control efficiency for NOX and CO for engines fueled with natural gas, propane or gasoline. In addition, the three-way catalyst shall also provide a minimum of 50% control efficiency for VOC for engines fueled by gasoline. ** ppmvd emission standards are corrected to 15% oxygen. 111 304.3 Emission Limits for Non-Emergency Engines That Are Located At A Major Source of NOX: An owner or operator of a non-emergency engine that is rated above 50 bhp and is located at a major source of NOX shall comply with the engine requirements in Table 324-3, as applicable, depending on the engine type: TABLE 324-3 ENGINE TYPE NOX* VOC* CO* PM 110 ppmvd or 800 ppmvd or Not Spark-Ignition Lean-Burn 1.5 g/bhp-hr 5.0 g/bhp-hr 4,500 ppmvd Applicable 20 ppmvd or 800 ppmvd or Not Spark-Ignition Rich-Burn 0.30 g/bhp-hr 5.0 g/bhp-hr 4,500 ppmvd Applicable 530 ppmvd or Not Compression-Ignition 6.9 g/bhp-hr Applicable 1,000 ppmvd 0.40 g/bhp-hr * ppmvd emission standards are corrected to 15% oxygen. 305 IDENTICAL REPLACEMENT ENGINE: An identical replacement engine shall be treated as the original stationary RICE that it replaces for the purposes of compliance with this rule. 306 NON-RESETTING TOTALIZING HOUR METER: The owner or operator of a stationary RICE, except for those engines being removed from service under Section 401 of this rule, shall install and operate a non-resetting totalizing hour meter. If the non-resetting totalizing hour meter is found to be malfunctioning, the owner or operator shall: 306.1 Record hours of operation daily until the function of the hour meter is restored; and 306.2 Restore the function of the hour meter within two weeks. Or, if it is not possible to restore the function of the hour meter within two weeks, the owner or operator shall notify the Control Officer in writing and provide a schedule for restoration of the function of the hour meter. SECTION 400 – ADMINISTRATIVE REQUIREMENTS 401 COMPLIANCE SCHEDULE-STATIONARY RICE BEING REMOVED FROM SERVICE: If a stationary RICE must be removed from service because such engine does not comply with the emission limits listed in Section 300 of this rule, then the stationary RICE shall be removed from service no later than [insert date one year after rule adoption]. The stationary RICE that replaces such engine shall comply with all applicable provisions of this rule upon installation. 402 COMPLIANCE SCHEDULE-NON-RESETTING TOTALIZING HOUR METER: The owner or operator of a stationary RICE that is not equipped with a non- resetting totalizing hour meter on [insert date of rule adoption], and is not being removed from service under Section 401 of this rule, shall install and operate a non-resetting totalizing hour meter on each such engine no later than [insert date one year after rule adoption]. 112 403 COMPLIANCE SCHEDULE-ENGINES AT A SOURCE THAT BECOMES A MAJOR SOURCE: If a non-emergency engine is located at a source that becomes a major source of nitrogen oxides after [insert date of rule adoption], the owner or operator shall demonstrate compliance with the emission limits in Table 324-3 within one year after the source becomes a major source of nitrogen oxides. SECTION 500 – MONITORING AND RECORDS 501 COMPLIANCE DETERMINATION: 501.1 Non-Emergency Engines That Are Not Located At A Major Source of NOX: An owner or operator of a non-emergency engine which is subject to the requirements in Section 304.1 or 304.2 of this rule shall demonstrate compliance using one of the following methods, as applicable: a. Provide documentation that the stationary RICE is certified by the manufacturer to comply with emission limits in 40 CFR 60 Subpart IIII or 40 CFR 60 Subpart JJJJ that are more stringent than the applicable emission limits in Table 324-1 or 324-2 of this rule, and provide documentation that the engine is installed, operated, and maintained in accordance with the manufacturer's specifications. b. Conduct a performance test in accordance with Section 501.4 of this rule at least once every 5 years. The performance test shall demonstrate compliance with one of the following requirements: (1) The applicable emission limits in units of grams per brake horsepower-hour (g/bhp-hr); or (2) The applicable emission limits in units of ppmvd; or (3) The three-way catalyst provides a minimum of 80% control efficiency for NOX and CO for engines fueled with natural gas, propane or gasoline, and the three-way catalyst also provides a minimum of 50% control efficiency for VOC for engines fueled by gasoline. c. Provide documentation that the non-emergency compression-ignition engine was manufactured or reconstructed (whichever occurred later) prior to October 22, 2003 and provide documentation that the non-emergency compression- ignition engine is equipped with a turbocharger with an aftercooler/intercooler. d. Provide documentation that the non-emergency compression-ignition engine was manufactured or reconstructed (whichever occurred later) prior to October 22, 2003 and: (1) Provide documentation that the injection timing has been set at 4 degrees below the factory setting for the engine. Written verification of the factory set timing, along with documentation that the engine timing has been delayed by 4 degrees must be submitted; or (2) Provide documentation that the injection timing has been set at 4 degrees below the manufacturer's standard timing of the engine. Written verification of the manufacturer's standard timing of the engine prior to tuning for NOX 113 control, along with documentation that the timing has been delayed by 4 degrees must be submitted; or (3) Provide documentation that the injection timing has been set at 16 degrees below top dead center or less (if information regarding the manufacturer's standard timing or factory set timing is not available). 501.2 Non-Emergency Engines That Are Located At A Major Source of Nitrogen Oxides: An owner or operator of a non-emergency engine which is subject to emission limits in Section 304.3 of this rule shall demonstrate compliance by conducting a performance test in accordance with Section 501.4 of this rule at least once every 2 years. The performance test shall demonstrate compliance with the applicable emission limits in units of grams per brake horsepower-hour (g/bhp-hr) or ppmvd. 501.3 Representative Performance Testing: An owner or operator may demonstrate compliance with the applicable emission limits or control efficiency requirements in Table 324-1, Table 324-2, or Table 324-3 of this rule by conducting representative performance testing in accordance with Section 501.4 of this rule, provided all of the following requirements are satisfied: a. The engines are located at the same stationary source; b. The engines were produced by the same manufacturer, have the same model number or other manufacturer's designation in common, and have the same rated capacity and operating specifications; c. The engines are operated and maintained in a similar manner; d. At least one engine or one third of the engines in the specified group, whichever is greater, are tested each time a performance test is required; e. Each time a performance test is required, different engines are tested so that all engines in the specified group are tested before any engines in the representative group are retested; and f. If emissions from any engine in the specified group exceed an applicable emission limit, or if the control efficiency for any pollutant controlled by a three- way catalyst is lower than the required control efficiency, the owner or operator shall demonstrate that each engine in the specified group is in compliance with the applicable limits by conducting a performance test on each engine in the specified group. 501.4 Performance Test Conditions: Performance tests shall be conducted using the test methods listed in Section 503 of this rule. Testing for stationary RICE shall be completed at either the maximum operating load or no less than 80% of the rated bhp. If the owner or operator of an engine demonstrates to the Control Officer that the engine cannot operate at these conditions, then emissions source testing shall be performed at the highest achievable continuous rated bhp or under the typical duty cycle or typical operational mode of the engine. The result of the performance test shall be the arithmetic mean of the results of three test runs. Each test run shall have a minimum sample time of one hour. 114 501.5 Fuel-Sulfur Verification: The owner or operator of an engine fueled with gasoline shall submit documentation that gasoline was purchased within the United States. The owner or operator of an engine fueled with diesel, natural gas, LPG, or an alternative fuel shall submit one of the following documents listing the accurate sulfur content of the fuel based on enforceable test methods as approved by the Administrator to determine the sulfur content: a. Fuel receipts, or b. Contract specifications, or c. Pipeline meter tickets, or d. Fuel supplier information, or e. Purchase records, or f. Test results of the fuel for sulfur content. 501.6 Waste Derived Fuel Gas - Sulfur Verification: The owner or operator shall submit documentation of the sulfur content of the waste derived fuel gas to the Control Officer upon request. The sulfur content of gaseous fuels shall be determined by South Coast Air Quality Management District Method 307-91 Determination of Sulfur in a Gaseous Matrix. 502 RECORDKEEPING/RECORDS RETENTION: The owner or operator of a stationary RICE subject to this rule shall comply with the following requirements and retain records for at least 5 years: 502.1 Stationary RICE List: Maintain a list of stationary RICE that includes all of the following information for each stationary RICE: combustion type (compression- ignition, or lean-burn spark-ignition, or rich-burn spark-ignition); manufacturer; model designation, rated bhp, serial number, and the location of each engine at the facility. If the equipment list associated with the current permit includes all of the required information for each stationary RICE located at the facility, this requirement may be fulfilled by keeping a complete copy of the current permit, including the equipment list, in a readily accessible location at the facility where the engines are located, and by providing the equipment list to the Control Officer upon request. 502.2 Operation Records: An owner or operator of a stationary RICE shall maintain records of the monthly and 12-month rolling total hours of operation for each stationary RICE. For emergency engines, the operation records shall also include: a. Monthly and annual hours of operation for reliability related activities such as engine readiness, calibration, or maintenance, or to prevent the occurrence of an unsafe condition during electrical system maintenance; and b. The number of operating hours for emergency use and an explanation for the emergency use. 502.3 Maintenance Records: An owner or operator of a stationary RICE shall maintain records of all stationary RICE maintenance (including the date when maintenance was performed and the maintenance procedures that were performed). If an owner or operator of a non-emergency engine demonstrates compliance with the requirements 115 in Section 304.1 of this rule using the method specified in Section 501.1(d) of this rule, the maintenance record shall include documentation of the injection timing setting each time maintenance is performed on the stationary RICE. In addition, one of the following documents shall be available at all times at the facility where the stationary RICE is located: a. The manufacturer’s written instructions for operation and maintenance of each stationary RICE; b. A written maintenance schedule provided by the manufacturer’s authorized service provider; or c. A written maintenance plan indicating which of the tuning procedures listed in Section 302 of this rule are applicable to each stationary RICE. 502.4 Fuel Records: a. Maintain records of the type and amount of fuel purchased for use in the stationary RICE (e.g. receipts, pipeline tickets, or bills of lading); and b. Maintain records of the sulfur content of any fuel that is used in the stationary RICE, excluding gasoline. For gasoline, maintain records that the fuel was purchased in the United States. 502.5 Manufacturer's Operation and Maintenance Instructions: An owner or operator of an engine that is subject to the requirements of Section 302 of this rule shall keep the manufacturer's written instructions for operation and maintenance of the engine available at the facility where the engine is located at all times. If the manufacturer's written instructions are not available, the owner or operator shall keep a preventative maintenance plan, indicating which procedures in Section 302 of this rule are appropriate to the engine, available at the facility where the engine is located at all times. 502.6 Nonroad Engine Records: An owner or operator of a nonroad engine shall maintain the following records for each non-road engine: a. Date that each engine is brought to the stationary source; and b. For engines located at a stationary source greater than 14 consecutive days: (1) Make, model, serial number, and rated capacity (bhp hours) of the engine; and (2) Date of each instance in which the engine is moved from its existing location, and the reason why the engine was moved; and (3) Fuel type and sulfur content of the fuel. 503 COMPLIANCE DETERMINATION-TEST METHODS INCORPORATED BY REFERENCE: The following test methods are approved for use for the purpose of determining compliance with this rule. The test methods are incorporated by reference in Rule 360 and Appendix G of the Maricopa County Air Pollution Control Regulations. Alternative EPA-approved test methods may be used upon written approval from the Control Officer. When more than one test method is permitted for the same determination, an exceedance under any method will constitute a violation. Copies of test methods referenced in this section are available at the Maricopa County Air Quality Department. 116 503.1 EPA Reference Methods 1 (“Sample and Velocity Traverses for Stationary Sources”) and 1A (“Sample and Velocity Traverses for Stationary Sources with Small Stacks or Ducts”) (40 CFR 60, Appendix A). 503.2 EPA Reference Methods 2 (“Determination of Stack Gas Velocity and Volumetric Flow Rate”), 2A (“Direct Measurement of Gas Volume Through Pipes and Small Ducts”), 2C (“Determination of Stack Gas Velocity and Volumetric Flow Rate in Small Stacks or Ducts”), and 2D (“Measurement of Gas Volumetric Flow Rates in Small Pipes and Ducts”) (40 CFR 60, Appendix A). 503.3 EPA Reference Methods 3 (“Gas Analysis for the Determination of Dry Molecular Weight”), 3A (“Determination of Oxygen and Carbon Dioxide Concentrations in Emissions from Stationary Sources (Instrumental Analyzer Procedure"), 3B (“Gas Analysis for the Determination of Emission Rate Correction Factor or Excess Air”), and 3C (“Determination of Carbon Dioxide, Methane, Nitrogen and Oxygen from Stationary Sources”) (40 CFR 60, Appendix A). 503.4 EPA Reference Method 4 (“Determination of Moisture Content in Stack Gases”) (40 CFR 60, Appendix A). 503.5 EPA Reference Method 5 (“Determination of Particulate Emissions from Stationary Sources”) (40 CFR 60, Appendix A) 503.6 EPA Reference Method 202 (“Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources”) (40 CFR 51, Appendix M). 503.7 EPA Reference Methods 7 (“Determination of Nitrogen Oxide Emissions from Stationary Sources”), 7A (“Determination of Nitrogen Oxide Emissions from Stationary Sources - Ion Chromatographic Method”), 7B (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Ultraviolet Spectrophotometry Method”), 7C (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Alkaline Permanganate/Colorimetric Method”), 7D (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Alkaline-Permanganate/Ion Chromatographic Method”), and 7E (“Determination of Nitrogen Oxide Emissions from Stationary Sources – Instrumental Analyzer Procedure”), (40 CFR 60, Appendix A). 503.8 EPA Reference Method 9 (“Visual Determination of the Opacity of Emissions from Stationary Sources”) (40 CFR 60, Appendix A). 503.9 EPA Reference Method 10 (“Determination of Carbon Monoxide from Stationary Sources”) (40 CFR 60, Appendix A). 503.10 EPA Reference Method 18 (“Measurement of Gaseous Organic Compound Emissions by Gas Chromatography”) (40 CFR 60, Appendix A). 503.11 EPA Reference Method 25A (“Determination of Total Gaseous Organic Concentration Using a Flame Ionization Analyzer”) (40 CFR 60, Appendix A). 503.12 ASTM D2622-05 (“Standard Test Method for Sulfur in Petroleum Products by Wavelength Dispersive X-Ray Fluorescence Spectrometry”). 503.13 ASTM D4294-02 or D4294-03 (“Standard Test Method for Sulfur in Petroleum and Petroleum Products by Energy-Dispersive X-Ray Fluorescence Spectrometry”). 117 503.14 ASTM D5504-01 or D5504-08 (“Standard Test Method for Determination of Sulfur Compounds in Natural Gas and Gaseous Fuels by Gas Chromatography and Chemiluminescence”). 503.15 South Coast Air Quality Management District Method 307-91 (“Determination of Sulfur in a Gaseous Matrix”), revised 1994. 118 MARICOPA COUNTY BOARD OF HEALTH MEETING MINUTES Monday, February 25, 2019 at 1:00 pm 301 W. Jefferson Street, 10th Floor, Phoenix, Arizona 85003 Board of Supervisors Conference Room President Hughes called the meeting to order at 1:02 p.m. Return to list of attachments ROLL CALL: Members Present: Members Not Present: Don Cassano Kristen Acton Henri Cournand (via phone) Robert MacMillan Andrew Rascón Nedra Halley Don Hughes Debra Baldauff Bill Gates Ex-Officio: Max Porter CALL TO THE PUBLIC: President Hughes announced that we have speaker slips for anyone wishing to speak on any action items. Speakers will be called after the item is heard. Each speaker will have 2 minutes to speak. No speaker slips were received. President Hughes introduced our newest member to the Board of Health. Mr. Andrew Rascón, District 5 Board of Supervisor Appointment. Mr. Rascón works for Southwest Center for HIV/AIDS and runs his own non-profit as well. Welcome and congratulations Mr. Rascón on your appointment as our newest member. DISCUSSION/ACTION ITEMS 1. Approval of Minutes: President Hughes asked for a motion to approve the BOH finance committee minutes from the BOH Meeting held on July 23, 2018. Motion was made by Mr. MacMillan to approve the BOH finance committee minutes as presented. Motion was seconded by Mr. Cassano and all were in favor. The motion passed unanimously. Approval of Minutes: President Hughes asked for a motion to approve the BOH minutes from the BOH Meeting held on July 23, 2018. Motion was made by Mr. Cassano to approve the BOH minutes as presented. Motion was seconded by Ms. Halley and all were in favor. The motion passed unanimously. 2. Approval of FY20 OMB budget request Mr. Scot Pitcairn Mr. Scot Pitcairn presented Department of Public Health’s budget request for FY2020. For Fiscal Year 2020 Public Health Department’s total base budget request for this year is $58,150,751, a decrease of 6.2% from the FY19 Revised budget. This consists of no increase to the General Fund budget, this fund remaining flat and on target, a 9.8% decrease in the Grant Fund budget, and 1% increase in the Special Revenue Fund budget. 119 A summary of our base budget request is as follows: General Fund $ 12,868,622 Grants Fund 36,271,166 Special Revenue (Fee) Fund 9,010,963 TOTAL $ 58,150,751 Operating Budget General Fund The general fund request is shown at target baseline level. No increases are being requested at this time. This is not intended to imply that all service levels are being adequately met. In order to remain at baseline targets we have budgeted 100% vacancy savings for one division administrator position and our PIO position and have eliminated one program coordinator position. Fee Fund The Fee Fund operating budget is submitted $322,248 below the FY19 Revised budget, reflecting a reduction in the Childhood Immunization budget that keeps expenditures within anticipated revenues. (This budget will be supplemented by non-recurring funding). Grant Fund The decrease of $4,159,112 in the Grant Fund results from the loss and reduction in several grants, including cuts to WIC, moving the Ryan White Dental Program to the Ryan White Office, reductions to Healthy Start, and various other grant losses or reductions. Non-Recurring Budget General Fund The $237,775 in one-time funding in the FY19 budget for the replacement X-Ray equipment at our TB Clinic was removed from the FY20 budget. Grant Fund For FY20 the grant carryover/non-recurring budget is $500,000, an increase of $215,000 over the FY19 budget. This increase reflects additional carry forward from the Smoke Free Grant and the HPHC (Healthy People Healthy Communities) integrated IGA grants. Fee Fund Following the model used last budget year, we have budgeted funds from our fee fund balance, increasing it from $593,300 in the current year to $1,000,000 in FY20. Of this amount, $200,000 is budgeted for our policy group. This group will use these funds for childhood vaccination advocacy and in addressing the opioid epidemic in our county. In addition, Vital Registration is budgeted $125,000 for expanding the east valley office. The Refugee Medical Assistance Program is budgeted to use $125,000 since they have run short in funding as a result of the current administration reducing the number of refugees admitted to the country. The remaining $550,000 is being allocated to address needs in the STD Control program, Childhood Immunization and other mandated areas. CSCA and ISF Last year we requested a review above baseline from the Board of Supervisors due to large deficiencies in our funding. We are not requesting a review this year but there is a funding gap that the Budget Office and county management are aware of due to the CSCA and ISF charges placed on the Department. Last year in order to balance our budget, $913,296 was used from our Fee Fund balance and $547,457 was designated from non-departmental funds in the event our indirect collections were insufficient to cover expenses. Due to two factors, first the reduction of grant receipts and second the increase over the last several years in CSCA and Internal Service Charges, our indirect collections are not sufficient to cover our administrative costs, ISF charges and CSCA 120 charges combined. Over the past ten years we have internally reduced our administrative staff by 10 positions, saving over $850,000. However, these reductions have increased the workload on existing staff to the point that we cannot reduce internally further and still function properly. Our rent is a sizable part of our internal charges but we cannot reduce that amount unless we are allowed to purchase a facility. Our current lease runs through 2023 and we are not certain whether we will be able to legally get out of the lease obligation before the lease expires. This shortfall is projected in our budget at $685,549. The solution to fill this gap is left open for further discussion before our budget recommendation is finalized. For this current fiscal year’s budget, the County Budget Office obligated $547,457 for this projected shortfall. We have held positions and generated vacancy savings with our director’s position to help reduce the use of this commitment, but those options will probably not exist in the next budget cycle. We also could tap further into our fee fund balance. Regardless of the solution for this problem, both of these options are only a Band-Aid and will not solve the problem of uncontrolled escalations of CSCA and ISF charges being pushed into limited grant funds. Further increases in our indirect rates will only further decrease the delivery of services for mandated and other services that public health is expected to provide to our community. Therefore, a more viable, longer-term solution needs to be researched. We should also note with this budget submission that the base-level operating budget is likely unable to handle an outbreak or emergency should one occur. The two items we see as likely are: 1) measles epidemiology responses and; 2) the treatment of MDR or XDR Tuberculosis cases. During this last year our community, along with large parts of the world, have dropped below the required vaccination rates in our schools to accomplish the herd immunity effect for disease prevention of vaccine preventable diseases. The most contagious of these is Measles. Measles outbreaks have occurred throughout Europe and other parts of the world and have occurred in 26 states during 2018. Europe has been fighting this previously contained disease spread for over a year. During last year, with a 93% vaccination rate (we are just under 95%) European nations had 64,000 cases of the disease. The main cost of our response will be in the epidemiological tracking of the outbreak; the cost of these can range from $50,000 to hundreds of thousands of dollars. This is why we have been so active in the work with the state to decrease the personal exemptions being given out to parents who do not vaccinate their children with the school-required immunizations. While the financial costs of these outbreaks are staggering, the risk of blindness, hearing impairment, pneumonia and death (1-2 deaths out of every 1,000 cases) can have drastic consequences for children and families. The second concern is one that we have seen during the last few budget years but the frequency seems to be escalating. This is the occurrence of multi-drug resistant (MDR) and extreme drug resistant (XDR) Tuberculosis (TB). This strain of TB is immune to the normal cost-effective drugs that we use to treat standard cases and requires two other types of drugs that are extremely expensive. A single case can easily cost between $100,000 and $150,000 over the course of their 18- month to 24-month treatment, and this does not include any surgically required responses. Non-compliant patients also incur court costs and isolation costs. We cannot predict the number of cases we will have, but if they do occur we will need to request additional funds as we have in the past. 121 Motion to approve the FY20 OMB budget request for Public Health was made by Ms. Halley, seconded by Mr. Cassano and all were in favor. The motion passed unanimously 3. Approval of FY20 OMB budget request Mr. Gus Martinez Mr. Gus Martinez presented Department of Environmental Services’ budget request for FY2020. FUND 100 (County General Fund) Requested budget for Fund 100 operating is $247,221 in revenues and $9,459,591 in expenditures. Revenues Agency 880 is funded by the County General Fund subsidy. Environmental Services collects enforcement revenue from non-permitted activities. These fines are associated with violations of the Environmental Health Code by persons and organizations not subject to obtaining a permit. Requested budgeted revenues remain at $247,221 with no change between FY2019 adopted and FY2020 requested. In FY2019 Environmental Services acquired the waste resources department which is tasked with operating the counties six transfer stations. These transfer stations collects approximately 220K in transfer station fees annually. 122 Expenditures Environmental Services General Fund Agency recommended operating budget expenditures are $9,459,591 or .73% increase from FY19 adopted. Requested budget includes a slight increase in the amount of supplies and services by 2% or $103,140 for increased costs in equipment repairs. Non-Reoccurring Expenditures The Departments recommended budget includes non-reoccurring expenses in Fund 100 in the amount of $100,003 for the following: IT Recommendations – $100,003 FUND 505 (County Grant Fund) Requested budget for Fund 505 operating is $67,198 in revenues and $67,198 in expenditures. Grant Funds Agency 881 is a grant from the Food and Drug Administration Department of Health and Human Services. Environmental Services was awarded the grant on September 10, 2015 in the amount of $67,198 for FY2020. The grant was approved by the Board of Supervisors on October 21, 2015. The purpose of the grant is to advance conformance with the voluntary national retail food regulatory program standards. The purpose of the grant is to advance conformance with the voluntary national retail food regulatory program standards. This grant will serve in assessing foodborne illness risk factors in Maricopa County and also provide permitted food operations with educational strategies to reduce the occurrence of foodborne illness risk factors. In Year 2, Environmental Services is providing education to all Environmental Health staff for implementing Active Managerial Control (AMC) principles during their inspections and train the operators to do the same (Train the Trainer). This training is based on the results of the survey conducted in Year 1. Also, MCESD will develop an AMC Toolbox, consisting of guidance documents, templates, logs, videos, and handouts on policies, training, and verification. These materials will emphasize the shift to a population that learns through the oral and visual delivery of information. Access to these materials will be streamlined via inspection reports, website design, and other mobile platforms. AMC will be further incentivized by increasing public awareness of the Department’s voluntary AMC program: the “Cutting Edge Food Safety Partnership.” Our Department will develop media to showcase Cutting Edge Program participants. Revenues Revenues remain unchanged from FY2019 to FY2020 requested and are mandated by the terms of the grant. Expenditures Expenditures remain unchanged from FY2019 to FY2020 recommended and are mandated by the terms of the grant. FUND 290 (Waste Tire Fund) Requested budget for Fund 290 operating are $5,825,000 in revenues and $5,825,000 in expenditures. Revenues Revenues are received from the State of Arizona to fully cover the expenses to the county. These fees are not directly collected by the county; they are collected through the purchase of a tire. Expenditures The Tire Fund expense budget has increased 14.97% from FY2019 to FY2020 to accommodate the increase tires received at the tire recycling facility. Year over year, the fund has seen increased costs based on the number of registered vehicles in Maricopa County. FUND 506 (Environmental Fee Fund) Requested budget for Fund 506 operating are $21,012,670 in revenues and $21,001,478 in expenditures. 123 Revenues Requested budgeted revenues for Fund 506 are $21,012,670 or $540,701 (3%) above FY2019 adopted. Pool, food permitting, and environmental plan review are all experiencing a higher than average permit and plan review submittals resulting in above budgeted revenue. This is primarily due to an uptick in construction projects as the economy improves. As plan review in both the Water and Waste and Environmental Health division’s continue to rise, so do the number of permits being added. Environmental Services expects these trends to continue through FY2020. Expenditures Requested budgeted expenses at $21,001,478 or $599,204 (2.85%) above FY19 adopted. Requested budget includes overall increase in personnel services by $348,968 or 2% with reductions to personal savings to accommodate the increased workloads. Supplies and services have been increased by $250,236 due to an increase in central services cost allocations. Non-Reoccurring Expenditures The Departments recommended budget includes non-reoccurring expenses in Fund 506 in the amount of $2,117,426 for the following: Vehicles - $750,000 Overtime – $125,000 Rent – $93,954 Contracting Services - $350,000 IT Recommendations – $798,472 Motion to approve the FY20 OMB budget request for Environment Health was made by Mr. MacMillan, seconded by Mr. Cassano and all were in favor. The motion passed unanimously 4. Fee Waiver Applications Ms. Jeannie Taylor Ms. Jeannie Taylor presented 60 fee waivers for review and consideration of approval. A summary sheet document was provided. Motion to approve the 60 fee waivers applications was made by Ms. Halley, seconded by Mr. Cassano and all were in favor. The motion passed unanimously. 5. Approval of initiation of regulatory change for the following rules: Gregory Verkamp Kimberly Butler Gregory Verkamp and Kimberly Butler presented 9 Rules for approval of initiation of regulatory changes. Gregory explained that all rules are the beginning/initiation process. 8 lf the 9 rules EPA is behind them and will ultimately have to be approved by the EPA. A. AQ-2017-002 Rule 321 (Municipal Solid Waste Landfills) The Maricopa County Air Quality Department (MCAQD) is proposing to revise Rule 321 to reflect the federal municipal solid waste landfill emission guidelines as promulgated August 29, 2016 and codified at Title 40 (Protection of Environment) of the Code of Federal Regulations (CFR), Part 60 (Standards of Performance for New Stationary Sources), Subpart Cf (Emission Guidelines and Compliance Times for Municipal Solid Waste Landfills). In addition, the MCAQD is proposing to incorporate changes recommended by stakeholders, and to make other changes to improve and clarify the rule. 124 Motion to approve Rule 321 (Municipal Solid Waste Landfills) was made by Ms. Halley, seconded by Mr. MacMillan and all were in favor. The motion passed unanimously. B. AQ-2017-007 Rule 322 (Power Plant Operations) Rule 323 (Fuel Burning Equipment from Industrial/Commercial/Institutional Sources) Rule 324 (Stationary Reciprocating Internal Combustion Engines) The MCAQD is proposing to revise Rules 322, 323, and 324 to address rule approvability comments provided by the Environmental Protection Agency (EPA). These changes are required in order for the EPA to approve these rules as Reasonably Available Control Technology (RACT) for control of nitrogen oxides, which are precursors to ozone formation. The MCAQD is also proposing changes to address rule improvement comments provided by the EPA, to incorporate changes recommended by stakeholders, and to make other changes to improve and clarify the rules. Motion to approve Rule 322 (Power Plan Operations), Rule 323 (Fuel Burning Equipment from Industrial/Commercial/Institutional Sources) and Rule 324 (Stationary Reciprocating Internal Combustion Engines) was made by Mr. Cassano, seconded by Ms. Halley, and all were in favor. The motion passed unanimously. C. AQ-2017-009 Rule 350 (Storage and Transfer of Organic Liquids (Non-Gasoline) at an Organic Liquid Distribution Facility) Rule 351 (Storage and Loading of Gasoline at Bulk Gasoline Plants and Bulk Gasoline Terminals) Rule 353 (Storage and Loading of Gasoline at Gasoline Dispensing Facilities) MCAQD is proposing to revise Rules 350, 351, and 353 to address rule approvability comments provided by the Environmental Protection Agency (EPA). These changes are required in order for the EPA to approve these rules as Reasonably Available Control Technology (RACT) to reduce volatile organic compound (VOC) emissions. The MCAQD is also proposing changes to address rule improvement comments provided by the EPA, to incorporate changes recommended by stakeholders, and to make other changes to improve and clarify the rules. Motion to approve Rule 350 (Storage and Transfer of Organic Liquids (Non-Gasoline) at an Organic Liquid Distribution Facility), Rule 351 (Storage and Loading of Gasoline at Bulk Gasoline Plants and Bulk Gasoline Terminals) and Rule 353 (Storage and Loading of Gasoline at Gasoline Dispensing Facilities) was made by Mr. MacMillan, seconded by Mr. Cassano and all were in favor. The motion passed unanimously. D. AQ-2017-010 Rule 210 (Title V Permit Provisions) The MCAQD is proposing to revise the MCAQD’s NSR rules in order to secure their approval as part of the State Implementation Plan (SIP) under the federal Clean Air Act. The MCAQD’s NSR rulemaking is comprised of seven (7) rules, including Rule 210. All of the NSR rules, with the exception of Rule 210, were approved for the initiation of regulatory change by the Board of Health at the July 23, 2018 meeting. Rule 210 was not initiated at that time because revisions to the rule were not anticipated. However, upon review of the U.S. Environmental Protection Agency’s (EPA’s) recommendations, the MCAQD is requesting approval for the initiation of regulatory change in order to revise Rule 210. Motion to approve Rule 210 (Title V Permit Provisions) was made by Mr. Cassano, seconded by Dr. Baldauff and all were in favor. The motion passed unanimously. E. AQ-2017-011 Rule 204 (Emission Reduction Credits for Use with the Arizona Emissions Bank) The MCAQD is proposing to revise Rule 204 to add provisions for nontraditional sources of emission reduction credits. Currently, the rule only allows for the generation, certification and utilization of emission reduction credits from permitted 125 sources. Proposed revisions include new provisions for the generation, certification, and utilization of emission reduction credits from nontraditional sources that use truck stop electrification, electric standby equipped transport refrigeration units, and electric onsite equipment. Revising the rule will provide additional sources of emission reduction credits that will allow Maricopa County to move towards attainment of the National Ambient Air Quality Standards while still allowing industrial growth. Motion to approve Rule 204 (Emission Reduction Credits for Use with the Arizona Emissions Bank) was made by Mr. Cassano, seconded by Dr. Baldauff and all were in favor. The motion passed unanimously. Discussion Items: 1. Public Health Report Max Porter I. Human Resources II. Communication III. Infrastructure IV. Strategic Planning V. Programs VI. Disease Update VII. Future Topics Max Porter presented the Director’s Public Health Report. The budget isn’t quite as depressing as the picture that was presented to you. Yes we have some concerns when it comes to our indirect balance, the central service cots, the ISF funds (administrative costs) that we’re hit with. This isn’t just a concern for us, it’s a concern for all grant funded departments or any department that has a grant. Budget office is looking into it and is looking for a solution. They understand that it’s not sustainable the way it’s going. We are working with them. We have sufficient funds for this year to get through. We have a year to work through this and get to a solution. Our department (Public Health) and Human Services are both heavily, heavily grant funded. We are both under the same Assistant County Manager Lee Ann Bohn. She is dedicated to working through this year to try to find a solution for that problem. We will get through this year. We will do what we always do and we will have a successful year. I do want you to be aware that it’s not quite as bleak as the picture would look on paper. We are a viable department and we are doing some wonderful things. We are part of the Big Cities Health Coalition. We’re not a city, we’re a county but we are the 3rd largest Health jurisdiction in the Country behind New York and LA. Majority of Health departments are run through the City organizations throughout the Country, your large metropolis areas. Back in the 50’s it was consolidated that all to the Counties because we could consolidate better across city borders if we did it all in one. We’re the 3rd largest. Part of being a part of this Big Cities Health Coalition it allowed us to go back to the meetings this year and we meet with the head of the CDC. We explained to them that part of the problem we are seeing in our Health Departments is that you’re (the CDC) is sending funding from the federal government, majority of our funding comes from the federal government, to the State. The State dictates how they will meet deliverables which often don’t work for an urban area like we are and rural areas. So the funding they are sending down is going through another massaging at the State level. The State is taking out administrative expenses and then it goes down to the County department level and fewer and fewer services after each one of these things happen are reaching the people. The CDC heard us. So in three months from that meeting we received our first notice from the CDC that they are sending out instead of a grant a cooperative agreement. It’s a guaranteed receipt of funds. We will be getting a new addition of 2.5 million dollars directly from the CDC for OPIOID control. The OPIOID Cooperative Agreement guaranteed funding will hit us in August. We are hoping that this will be a beginning of the way grant funding will flow to us. It gives us a lot better ability to change direction when a new problem hits us. Rather than waiting for the State to determine that it is a problem this will give us the ability to change a grant deliverable directly. We’re hoping that, that will be a good change for the future of the way our funding comes in. 126 As part of the director’s report here, the big question that if you don’t have you should have is when are we going to get a new director? We are moving towards that direction. We have some very viable candidates that are in, we have some good resumes and we’re doing interviews now. So we are hopeful that by your next meeting you will have a real director that will be giving you this report. We’re hopeful that someone will be here and if they’re not here we will at least have the name and date of when they will be here. Childhood Vaccinations You’re seeing reports almost daily in the news about childhood vaccinations. There is a huge debate with a large amount of anti-vaxxers, I shouldn’t say large, there is a loud contingency of anti-vaxxers that are in the community. You have to remember that we lost our herd immunity with our childhood immunizations. The majority of the population understand the importance of immunizations. They understand that they have to participate if we’re going to protect the entire populous. There are also 2-3% can’t get vaccinations, they are people that are under treatment for cancer or they are immune suppressed. The anti-vaxxers make up about 3% and they are extremely loud and they’re campaigning against vaccinations. 6 bills in legislature o 3 of the bills could really damage our vaccinations o The anti-vaxxers are pushing harder and harder to give people personal exemptions for whatever reason. o With legislation we can’t lobby, all we can do is educate. o The Arizona Partnership for Immunization (TAPI), Right now should be our peak of flu season H1N1 is hitting again Congenital Syphilis Maricopa County Congenital Syphilis rates have doubled in the last 2 years. We have been said to be #1 in the nation, we are actually #5 By statute – 1st trimester tested, 3rd trimester tested o While it’s horrible the fix is simple Tested at delivery AHCCCS is on board Physicians reminded to test for syphilis in pregnant women Community Health Survey MaricopaHealthMatters.org Why the Health Survey Matters o Every three years, Maricopa County Department of Public Health, in collaboration with health care and community partners, conducts a Community Health Survey to develop a deeper understanding from residents about issues that relate to quality of life, availability of services, physical and mental health, and more. o The survey is part of a larger review of community health. This goes beyond individual health to look at what is affecting the community overall, what health issues are affecting some communities more than others, and what other factors contribute to those issues. o This research is supported by Synapse, a collaboration of healthcare partners, and the Health Improvement Partnership of Maricopa County (HIPMC). o It is part of a broader review of the community’s health conducted in collaboration with seven healthcare partners and over one hundred community organizations. o MCDPH needs this to remain an accredited health department. o Questions come from the National Association of County and City Health Organizations (NACCHO), the Institute for Healthcare Improvement (IHI) and MCDPH staff, and are finalized for 2019. o Data from this survey and the countywide health review are used to target programs, funds, and attention to health needs with the greatest potential for impact and improvement. 127 How the Survey is Being Conducted o Goal is 15,000 surveys countywide with representation from all cities and towns o Responses will be collected from March 1-May 31, 2019 o Robust outreach plan developed with partner organizations assisting in data collection What You Get and How You Can Help What you can get o Access to de-identified data o More responses will allow for more segmentation in data analysis How you can help o Take the survey as a county resident o Utilize MCDPH outreach toolkit to share the survey with your personal and professional networks o Possible partnership with MCDPH epidemiologists to clean and analyze data Community Health Improvement Plan – Grant Opportunity Shared Use - https://www.maricopa.gov/4386/Shared-Use Opening doors to physical activity and healthy eating. Opportunities for physical activity and access to healthy food are essential for health at all ages and stages of life. Many neighborhoods throughout Maricopa County have limited access to spaces for children, youth, adults, and seniors to easily choose to be active and to eat more nutritious food. By opening doors and expanding access to existing facilities, we can improve health and well-being across the community. Maricopa County Department of Public Health (MCDPH) is offering grant funding up to $5000, per site, to increase the number of spaces in under-served areas, so those community residents can: play exercise and take part in recreational activities, grow healthy food and participate in nutrition related activities. Goal 100 schools opened $100,000 ($1500 - $5000 increments) School, Church or any public access Grant open until June 30th or until funding is gone Interested candidates must submit their response either by mail or email no later than May 31, 2019. For full details, a copy of the request for quote (RFQ), or to submit a response, please visit: bit.ly/opendoorsgrant ANNOUNCEMENTS AND CURRENT EVENTS Next Meeting – April 22, 2019 ADJOURNMENT: There being no further business, motion to adjourn the meeting was made by Ms. Halley, seconded by Mr. Cassano and motion was passed unanimously. The meeting was adjourned. 128 Return to list of attachments April 26th 2021 Board of Health Meeting Minutes Placeholder 129 Copies of all written and electronic Stakeholder input From: Suzanne Kennedy <suzanne.kennedy@asu.edu> Return to list of attachments Sent: Wednesday, August 22, 2018 9:28 AM To: Kristi Beck (AQD) Subject: Rule Meeting Today and Comments on 322, 323, and 324 Hi Kristi, I have been called into a meeting today and won’t make it to the rule meetings today. I just have a few comments as follows: 1. Rule 322, Section 501.1 – This rule now requires records of the type and amount of fuel used, sulfur content and days and hours of operation. I would like to remove the requirement to track days and hours of operation and that fuel use be required to be tracked monthly. Fuel tracking monthly makes the most sense since invoices are typically sent monthly (in the case of natural gas). I have been unable to identify a reason to track days and hours of operation. This information does not appear to be needed to determine compliance. 2. Rule 323, Section 501.1 – This rule contains similar requirements for tracking fuel use and days/hours of operation. I would like to request the same change as stated above. 3. Rule 324, Section 502.4.a – The hours of operation for emergencies should be specified in this section and testing, reliability and maintenance hours should be grouped together as non‐emergency hours. Suggested language is: “Monthly and rolling twelve month total hours of operation, emergency hours of operation, and non‐emergency hours of operation (including hours for testing, reliability, and maintenance).” I am so sorry that I won’t make it. Please call me if you have any questions. Thanks! Suzanne Suzanne Kennedy Associate Director, Environmental Compliance Environmental, Health, and Safety Arizona State University Cell ‐ 602‐460‐8173 Desk – 480‐965‐1893 130 From: Ryan.Sweetwood@aps.com Sent: Thursday, August 30, 2018 1:42 PM To: Kristi Beck (AQD) Cc: Eric.Massey@aps.com; Charles.Spell@aps.com Subject: Rule 323 Comments Kristi I tried submitting through EROP and something with my security is blocking me. I will try again tomorrow but wanted to make sure I sent this over. In Maricopa County’s (the County) workshop presentation, the County recommends accepting the more stringent boiler tuning requirements and suggests requirements based rated capacity and whether or not the source was at a major source. Concerning the County’s recommendations for altering requirements based on rated capacity of the unit, APS suggests an alternative. APS has reviewed EPA’s comment and believe EPA was intending to apply RACT to “major source units” (units emitting 100 tons/yr of NOx) and not a minor source unit at a “major source” as suggested by the County’s proposed commitment. APS requests that RACT requirements only apply to major source units. Applying a major source applicability limit would be consistent with EPA’s recommendation with Rule 322. APS owns a Clayton Boiler rated at 11 MBtu/hr, which emits approximately 25 lbs per year. APS has reviewed the examples for boiler tuning requirements and find them excessive in some situations for simple and small units. Multiple items in the referenced boiler tuning requirements could not work for this unit. APS doesn't support more stringent requirements for the smaller units. At a minimum, there should be language that accommodate the size and design of the unit. Thanks, Ryan Sweetwood Environmental Air Consultant Arizona Public Service 400 N. 5th St., Phoenix, AZ 85004, Mail Station 9303 P.O. Box 53999, Phoenix, AZ 85072, Mail Station 9303 Cell (602) 478‐8333 Office (602) 250‐5153 ryan.sweetwood@aps.com ‐‐‐ NOTICE ‐‐‐ This message is for the designated recipient only and may contain confidential, privileged or proprietary information. If you have received it in error, please notify the sender immediately and delete the original and any copy or printout. Unintended recipients are prohibited from making any other use of this e‐mail. Although we have taken reasonable precautions to ensure no viruses are present in this e‐mail, we accept no liability for any loss or damage arising from the use of this e‐mail or attachments, or for any delay or errors or omissions in the contents which result from e‐mail transmission. 131 From: Caitlin Brady - MCDOTX <CaitlinBrady@mail.maricopa.gov> Sent: Wednesday, May 1, 2019 8:22 AM To: Michelle Mada (AQD); Gregory Verkamp (AQD); Johanna Kuspert (AQD); Kimberly Butler (AQD) Subject: FW: Online Form Submittal: Citizen Comments From: noreply@civicplus.com [mailto:noreply@civicplus.com] Sent: Wednesday, May 1, 2019 8:18 AM To: Regulatory <regulations@mail.maricopa.gov> Subject: Online Form Submittal: Citizen Comments Citizen Comments Each Regulatory Department is committed to providing opportunities for stakeholder input regarding the adoption and amendment of all regulatory requirements. Your input will be collected and forwarded to the appropriate department. You will receive a written response from the applicable department within two business days. We appreciate your comments and your time. Case Number/Rule AQ-2017-007 Rule 324 Stationary Reciprocating Internal Combustion Engines (RICE) Department Air Quality I would like to Other First Name Jon Last Name Sherrill Organization City of Chandler - Environmental Management City Chandler Zip 85225 Email jon.sherrill@chandleraz.gov Phone Number 480-782-2387 Phone Type Work Would you like someone Yes to contact you? 132 Comments We recently had several air permit inspections for our general permits that are for our emergency generators. We have been having these inspections every other year for our facilities and not had any major issues during the inspections. Each generator has a logbook that has a monthly record for the checks that take place, any operation or other issues that occur. Historically, these records were used to calculate the 12 month hours of operation to show compliance with permit conditions. However, during our recent inspections, we were informed that we had not been keeping a monthly rolling record of hours and that we needed to begin this for our general permitted sites. I've reviewed the permit and Rule 324 and understand that this is required but seems like an unnecessary effort if we keep a monthly log of hours. The previous 12 months can easily be calculated by taking March 2019 hours and subtracting March 2018 hours to show the current 12 months of hours of operation. The City of Chandler emergency generators typically run less than a couple hours a month, often times even less than a couple hours. The City understands the permit language and will do what is needed to maintain compliance. However since our sites have been inspected frequently and this has not previously been noted nor has it been noted as a compliance issue. The City believes that for remote sites that also run very limited hours that the information needed to determine hours of operation can be calculated from the on-site logbooks during inspections. Our emergency generators are typically at unmanned facilities, have limited use and would require additional effort and resources to collect and track this information. We hope to see this requirement addressed through logbook information that is maintained at each site and not a requirement to create spreadsheets for each generator (we have over 30 permitted sites). Since Rule 324 is currently being reviewed and possibly amended we hope that this issue can be addressed during this process. We would like to see this section clarified that for limited use, unmanned sites that the on-site logbook can be used to determine the 12 month hours of operation. If applicable, attach Field not completed. supporting documentation associated with your comment. Email not displaying correctly? View it in your browser. 133 Subject: FW: Follow-Up: Maintenance Requirements for Emergency Generators From: Carlton, Anne B <Anne.Carlton@aps.com> Sent: Friday, May 24, 2019 11:09 AM To: Kristi Beck (AQD) <Kristi.Beck@Maricopa.gov> Subject: RE: Follow‐Up: Maintenance Requirements for Emergency Generators Hello Kristi, First, thank you so much for meeting with us to discuss maintenance related issues with our IC engines! We have reviewed the language and our operations across our fleet. We are requesting the following change to the verbiage (see below). We have engines from 15 different manufactures (some are no longer in business) and only use a single qualified service provider. The use of one contractor to conduct engine is preferred by our Supply Chain because of the clearance required to work at some of our sites as well as safety hazards associated with our facilities. There are some service providers that have safety records that prohibit them from working at our sites entirely. An owner or operator of a stationary RICE shall maintain the stationary RICE in accordance with the manufacturer's written instructions or in accordance with the written maintenance schedule provided by the manufacturer’s authorized a qualified service provider. If the manufacturer's written instructions are not available and the manufacturer’s authorized qualified service provider does not provide a written maintenance schedule, the owner or operator shall conduct preventative maintenance according to the following schedule, including all of the following procedures, if the engine is so equipped, and if such procedures are appropriate to the type of engine: Thank you, Anne 134 Subject: FW: Stakeholder Workshop Update - Rule 324 (Stationary Reciprocating Internal Combustion Engines) From: Tveit, Oddvar <oddvar_tveit@tempe.gov> Sent: Friday, November 15, 2019 6:30 PM To: Kristi Beck (AQD) <Kristi.Beck@Maricopa.gov> Cc: Hoppes, Christina <Christina_Hoppes@tempe.gov>; Mikus, Jeremy <jeremy_mikus@tempe.gov> Subject: RE: Stakeholder Workshop Update ‐ Rule 324 (Stationary Reciprocating Internal Combustion Engines) Dear Kristi, Thanks for the opportunity to provide comments in your chat room during the October 24, 2019 workshop. I notice of you could not accept a proposed comment [KB‐A30] about changing the term “manufacturer’s authorized service provider” with the term “qualified service provider” because this is not a recognized term in use by the EPA. We agree with the commenters concern about the term “authorized service provider” because the term in our opinion raises proprietary issues related to maintenance documentation provided by engine and/or emergency generator manufacturers exclusively to authorized dealerships. A regular maintenance provider may have authorizations from various engine manufacturers but may not be able to get authorizations from for example emergency generator manufacturers who have their own non‐road engines installed. We suggest you consider alterative options and include language in Section 302 about “or authorization from a manufacturer of a similar engine type” and “in accordance with recommendations from the manufacturer of a similar engine type.” Than You, Oddvar Tveit Environmental Quality Specialist PO Box 5002 Mail Stop 23‐1 Tempe, AZ 85280 (480) 350‐8300 oddvar_tveit@tempe.gov 135 Subject: FW: Online Form Submittal: Citizen Comments From: noreply@civicplus.com <noreply@civicplus.com> Sent: Thursday, April 8, 2021 2:18 PM To: PND Regulatory <PNDRegulatory@maricopa.gov>; Kathy Semder (COA) <Kathy.Semder@Maricopa.Gov>; Andy Linton (OBM) <Andy.Linton@Maricopa.Gov>; Bill Leal (OBM) <Bill.Leal@Maricopa.Gov>; Kathryn Garcia (OBM) <Kathryn.Garcia@Maricopa.Gov>; Blanca Caballero (ENV) <Blanca.Caballero@Maricopa.gov> Subject: Online Form Submittal: Citizen Comments Citizen Comments Each Regulatory Department is committed to providing opportunities for stakeholder input regarding the adoption and amendment of all regulatory requirements. Your input will be collected and forwarded to the appropriate department. You will receive a written response from the applicable department within two business days. We appreciate your comments and your time. Case Number/Rule AQ-2017-007 Rule 324 Stationary Reciprocating Internal Combustion Engines (RICE) Department Air Quality I would like to Other First Name Tom Last Name Ekren Organization Field not completed. City Tempe Zip Field not completed. Email tom.ekren@asu.edu Phone Number 6025433632 Phone Type Work Would you like someone to Yes contact you? Comments Hello Scott and Kim, 136 I hope all is well! I have a few comments for draft Rule 324, which deals explicitly with non-road engines. I understand the purpose of tracking non-road engines and the amount of time they are onsite to ensure there is no circumvention of the rules by using a non-road engine as a stationary engine. Unfortunately, the record-keeping requirement can be quite burdensome for facilities with special events that use non-road generators for a minimal amount of time. Almost all non-road generators are brought onto the site and removed in less than a week, and many within 24 hours. Could there be a timeframe, such as seven days, that if a non-road engine is brought onsite for more than seven days, then section 502.6 applies? Additionally, the serial number requirement in Section 502.6 b. can be difficult to obtain depending on the situation. Rental companies will have the make, model, and capacity readily available for the non-road engines being rented, but not the specific serial number sent to the site. If the non-road engine is brought onto the site for a single night event, it can be challenging to obtain the serial number for an event that lasts three hours at night. Thank you for reviewing my comments. If you have any questions, please do not hesitate to call or email me. Take care! Tom Ekren Environmental Professional Arizona State University Safety in the Built Environment Environmental Health and Safety University Services Building 1551 S. Rural Road Tempe, AZ 85281 Campus Mail Code 6412 Phone: 602-543-3632 General OHS Safety Email safety@asu.edu Visit EH&S Web Page: http://cfo.asu.edu/ehs Visit ASU Home Page: http://www.asu.edu/ please consider the environment before printing this email 137 If applicable, attach Field not completed. supporting documentation associated with your comment. The only file types supported are MS Office and Adobe Acrobat. Email not displaying correctly? View it in your browser. 138 Return to list of attachments UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION IX AIR DIVISION Technical Support Document for EPA’s Rulemaking for the Arizona State Implementation Plan Maricopa County Air Quality Department Rule 323 Fuel Burning Equipment from Industrial/Commercial/Institutional (ICI) Sources Prepared by: Kevin Gong December 11, 2019 139 RULE IDENTIFICATION Agency Maricopa County Air Quality Department (MCAQD) SIP Approved Rule 323 – Fuel Burning Equipment from Rule Industrial/Commercial/Institutional (ICI) Sources Revised – October 17, 2007 Submitted - January 9, 2008 EPA Approved – October 14, 2009 (74 FR 52693) Subject of this Rule 323 – Fuel Burning Equipment from TSD Industrial/Commercial/Institutional (ICI) Sources Revised – November 2, 2016 Submitted – June 22, 2017 Completeness Complete by operation of law – December 22, 2017 Finding BACKGROUND The Maricopa County Air Quality Department (MCAQD) regulates Maricopa County and the cities of Phoenix, Mesa, Scottsdale, Tempe, Chandler, Glendale, as well as 17 other jurisdictions and unincorporated County lands. Part of the area regulated by MCAQD is included in the Phoenix-Mesa area designated as nonattainment for ozone and classified as Moderate for the 2008 8-hour National Ambient Air Quality Standard (NAAQS) (see 40 CFR 81.303, 81 FR 26699). Rule 323, “Fuel Burning Equipment from Industrial/Commercial/Institutional (ICI) Sources,” regulates process heaters, steam units and turbines. The MCAQD identified one facility that is both a major source of nitrogen oxides (NOx), and has equipment subject to this rule: the Arizona Public Service’s West Phoenix Power Plant. The non- electricity generating equipment at West Phoenix Power Plant must therefore implement RACT for NOx emissions. Another facility with applicable equipment was identified by the MCAQD, but is not a major source of NOx: New Wincup Holding’s polystyrene cup manufacturing operations in Phoenix. This equipment is not required to meet RACT because New Wincup is not a major source of NOx, but we will review the rule’s applicable requirements for this equipment to ensure that they meet all other CAA requirements. Rule 323 was revised as part of the District’s process to ensure that its rules meet the reasonably available control technology (RACT) requirements of Section 182(b) of the Clean Air Act (CAA) for ozone nonattainment areas classified as Moderate. Appendix 1 of the June 22, 2017 submission, Revisions To The State Implementation Plan Revision For The Maricopa County Air Quality Department Ozone Rules Contained In The Arizona SIP, titled Analysis Of Reasonably Available Control Technology For The 2008 8-Hour Ozone 140 National Ambient Air Quality Standard (NAAQS) State Implementation Plan (RACT SIP) (“SIP Analysis”) contains the District’s analysis regarding whether Rule 323 implements RACT levels of control. RULE SUMMARY Rule 323 regulates NOx, sulfur oxide, carbon monoxide, and particulate matter emissions from steam generating units, cogeneration steam units, indirect-fired process heaters and turbines not located at power plants. Incinerators, crematories, burn-off ovens, kilns, direct-fired process heaters, reciprocating internal combustion equipment, equipment associated with nuclear power plant operations, and water heaters used for the sole purpose of heating hot water for comfort and for radiant heat are exempt from this rule. The NOx requirements are contained in section 304 of this rule, and apply to equipment in different ways based on their heat input rating or combustion type. Subsection 304.1a requires good combustion practices and tuning, while subsection 304.1b requires compliance with numeric emission limits. Both requirements apply to gas turbines and all units rated larger than 100 MMBtu/hr, while all other smaller units may comply with one or the other. The rule also describes related recordkeeping, reporting, and monitoring requirements. Changes from the approved SIP rule include: 1. Removed exemptions for turbines used at military facilities 2. Clarified exemption for all units for low use testing operations that are less than 36 hours per year. 3. New definition for “Steady State,” and “Ultra Low Sulfur Diesel.” 4. Clarification in section 302 for measurement periods temperature differential in turbine units for good combustion practices. 5. Clarified language in section 304 for NOx requirements. 6. Strengthened RACT emission limits for NOx. Gaseous fuel fired operations are limited to 42 ppmv, and liquid fuel-fired operations are limited to 65 ppmv. 7. Carbon monoxide and particulate matter requirements now only allow compliance determination during steady state operations. 8. Emission control equipment installed to comply with the pollution limits in this rule are only acceptable if the equipment can demonstrate compliance with the emission limits. Previously, any emission control system could be installed to comply with emission standards regardless of its effectiveness. 9. New administrative requirements were added to section 400, which had previously been reserved. The administrative requirements generally consist of compliance schedules for units to submit an operations and maintenance plan, or to modify or install an emissions control system. 10. New recordkeeping and monitoring requirements are in sections 503.3 (for continuous emission monitoring systems (CEMS) to meet the good combustion evaluation requirements) and 501 (to require maintaining records for low use units exempt in section 102). 141 11. New gaseous emissions source testing requirements, including a triennial source test interval for units rated larger than 100 MMBtu/hr. 12. Additional options for ultra low sulfur diesel fuel verification, and for waste derived fuel gas sulfur verification. 13. An updated list of approved test methods for this rule. EVALUATION CRITERIA The following criteria were used to evaluate the submitted rule. Enforceability The Bluebook (Issues Relating to VOC Regulation Cutpoints, Deficiencies, and Deviations, EPA, May 25, 1988) and the Little Bluebook (Guidance Document for Correcting Common VOC & Other Rule Deficiencies, EPA Region 9, August 21, 2001) were used to help evaluate compliance with the CAA §110(a)(2)(A) requirement for enforceability. Stringency SIPs must require RACT for each category of sources covered by a Control Technique Guideline (CTG) document as well as each major source of NOx or VOC in ozone nonattainment areas classified as Moderate or above (see sections 182(b)(2) and 182(f)). While there is no CTG for this source category, the MCAQD has identified major sources of NOx covered by this rule within the nonattainment area. Accordingly, the RACT requirement applies to these major sources. The EPA has published an Alternative Control Techniques (ACT) document titled, “NOx Emissions from Stationary Gas Turbines” (EPA 453/R- 93-007, January 1993) which describes available control techniques and their estimated costs for gas turbine units. The EPA’s ACT document titled, “NOx Emissions from Industrial, Commercial & Institutional Boilers” (EPA453/R-94- 022, March 1994) describes similar control techniques and cost guidance for boiler units. These ACTs and other state and local rules for this category were used to help evaluate the RACT requirements of CAA §182(b)(2) and §182(f). SIP Relaxation CAA §110(l) prohibits EPA from approving any SIP revision that would interfere with any applicable requirement concerning attainment and reasonable further progress or any other applicable requirement of the CAA. In addition, CAA §193 prohibits the modification of any SIP-approved control requirement in effect before November 15, 1990, in a nonattainment area, unless the modification insures equivalent or greater emission reductions. 142 EPA EVALUATION A summary of our evaluation of the three criteria follows. Enforceability Rule 323 applies to turbines, steam generating units, and cogeneration units not used for electricity generation. Incinerators, crematories, burn-off ovens, kilns, direct-fired process heaters, reciprocating internal combustion equipment, equipment associated with nuclear power plant operations, and water heaters used for the sole purpose of heating hot water for comfort and for radiant heat are exempt. Units firing on emergency fuel, units testing on emergency fuel, gas turbines used in fire-fighting, flood control, or in research and development are partially exempt from the requirements of this rule. The partial exemptions include an exemption from the NOx limits. We believe that most of these partial exemptions are reasonable, with the exceptions of the partial exemption for units fired on emergency fuel and for testing on emergency fuel. Other jurisdictions with a similar emergency fuel exemption limit the total hours of emergency fuel firing. Other jurisdictions also require that the County or District be promptly notified upon switching to emergency fuel. A fuel emergency should require owners or operators of equipment to take extraordinary actions if necessary to continue operations, or to shut down until the emergency passes. Any equipment that is necessary for public safety are already covered under other exemptions. Therefore, we find that the exemption for firing on emergency fuel is overly broad, as other similar regulations for ozone nonattainment areas provide limits for the length of emergency fuel use. The exemption for testing on emergency fuel as currently drafted could be interpreted to allow for exemption from emission limits in any operating scenario as long as the unit has fired on emergency fuel for testing in a year. This language should be clarified to indicate that this exemption applies while this testing is ongoing. Beyond these two aforementioned enforceability issues, the other applicability criteria are clear and establish which units must comply with this rule. Section 200 includes definitions for terms used in this rule. There are several new definitions and terms in Rule 323 which improve clarity, but there are other terms used in the rule, such as “boiler” and “continuous emissions monitoring system” that lack definition. This weakens rule enforceability, and these terms should be defined in the rule. Section 300 contains the limits and requirements for controlling emissions from applicable sources, including PM, sulfur, CO, and NOx. PM control 143 requirements are set out as fuel limits, backhalf analysis for testing, and good combustion practice requirements for turbines. Sulfur requirements are set out as a fuel limit. CO limits apply to units rated larger than 100 MMBtu/hour. The NOx requirements at Section 304 are split into two categories. This section requires non-turbine units to comply with operational requirements including burner inspection, regular tuning, and good combustion practices, or with specified emission limits, or both categories, depending on unit size. Turbines must comply with both categories regardless of size. We find these requirements to be sufficiently enforceable. Section 306 describes requirements for emission control systems that are installed to reduce pollution. Section 306.1 states that an owner or operator of an operation which may exceed the other standards in section 300 may comply by installing an operating an emission control system (ECS) which reduces emissions to below the applicable standards. However, there is no subsequent requirement for compliance determination to ensure that the ECS functions to actually meet the gaseous limits. Our discussion in the “Rule Deficiencies” section contains additional analysis. Section 400 contains compliance schedule requirements for units operating an ECS to submit to the MCAQD an Operations and Maintenance Plan (to be completed no later than July 2, 2017), submit a schedule for modification to an ECS if such a modification is necessary to demonstrate full compliance with the rule (a modified ECS must be installed and achieving compliance no later than November 2, 2018), and to submit a schedule for the installation of an ECS if new equipment is necessary (new equipment must be installed and in compliance no later than November 2, 2019). These dates are reasonable and support rule enforceability. Section 500 of the rule contains recordkeeping and reporting requirements for all equipment subject to this rule, including requirements for units claiming exemptions. Compliance demonstration requirements are outlined with the requirements themselves in Section 300 “Standards,” but several applicable requirements are also in Section 503. These requirements include requirements for verifying sulfur content in fuel, source test frequency, and requirements for CEMS. The frequency for gaseous emissions source testing is set to be done on at least a triennial basis for units with a heat input greater than 100 MMBtu/hour. Units rated less than this are not required to conduct source tests according to any frequency. Such units could be located at major sources of NOx and would lack any compliance determination requirements for NOx emissions limits. Such NOx emission limits would therefore be unenforceable for units in this size class. We find this provision deficient. 144 Other recordkeeping and reporting requirements include operating hour and days of operation for all units, fuel use requirements and fuel switching records, CEMS records, records demonstrating the maintenance of good combustion practices, and records for annual capacity factor utilization and NOx emissions. All records shall be retained for at least 5 years. Other than the deficiency identified with gaseous emissions source test frequencies, we find these monitoring, recordkeeping, and reporting requirements are adequate in supporting rule enforceability. Stringency Rule 323 establishes lower NOx emission limits for applicable units, of 42 ppmv for gas fired units, and 65 ppmv for liquid-fired units, but also allows smaller non-turbine units (smaller than 100 MMBtu/hr) to comply with certain operation practices instead of the numeric limits. These good combustion practices include requiring annual tuning of the unit, burner unit inspection, air-to fuel ratio calibration, and NOx and CO concentration measurements via portable analyzer. The emission limits are consistent with limits for stationary turbines in other jurisdictions needing to meet RACT, including units of all sizes in the Imperial County Air Pollution Control District and in the Mojave Desert Air Quality Management District, and for smaller units in the San Joaquin Valley Air Pollution Control District, Ventura County Air Pollution Control District, and the Yolo-Solano Air Quality Management District. However, these emission limits are not demonstrated to be suitable RACT NOx limits for boilers, process heaters, and steam generating units. RACT limits for these units in these other jurisdictions are commonly lower: at 30 ppmv for gas-fuel fired operation and 40 ppmv for liquid-fuel fired operations. A requirement consistent with at least these limits for NOx control must be included in this rule in order to ensure that any such applicable units are implementing RACT. Furthermore, non-turbine units smaller than 100 MMBtu/hr may choose to comply with only the good combustion practice requirements, with are not demonstrated to be RACT for the units that may be operating at major sources of NOx. Our analysis below in the “Rule Deficiencies” section provides further discussion on this issue. SIP Relaxation Many of the provisions in this rule are unchanged or more stringent than the SIP approved rule. Therefore, we find that the rule revisions are consistent with CAA sections 110(l) and 193. 145 RULE DEFICIENCIES The following deficiencies were identified in a letter dated July 18, 2018, and preclude full approval of the rule into the SIP1: 1. The emergency fuel use exemptions in Section 104 are overly broad. To correct this, the MCAQD should clarify in this section that emergency fuel is only allowed under natural gas curtailments or natural gas emergencies. The MCAQD should further limit the total allowable length of emergency fuel burning to be consistent with other jurisdictions (see, Imperial County APCD Rule 400.1 Section D.3) Also, Rule 323 does not require that the facility owner/operator notify the MCAQD when switching to emergency fuel, which Rule 322 “Power Plant Operations” (which regulates similar types of combustion equipment) does. This is an enforceability issue. Finally, the language in section 104 exempting units firing emergency for testing purposes could be interpreted to allow for the exemption during any operating period so long as the there was a testing period. The MCAQD should clarify that the exemptions only apply during the testing period. 2. All major sources of NOx must be subject to RACT limits or requirements. All turbines, and all boilers rated larger than 100 MMBtu/hr must comply with the limits in section 304.1.b. Boiler units rated between 10 MMBtu/hr and 100 MMBtu/hr may opt to comply with the limits in section 304.1 .b, or tune the units annually as required in section 304.1a. The burner maintenance requirements in section 304.1 .a are not RACT, as other jurisdictions regulating units in this size category are able to achieve numeric limits (down to 5 MMBtu/hr in Imperial County APCD Rule 400.2) or have more stringent tuning requirements (as seen in Ventura County APCD Rule 74.15.1 and South Coast AQMD Rule 1146, Attachment A). As the rule is written, major source units in the nonattainment area are only required to tune the engine instead of complying with a RACT NOx limit. MCAQD must clarify that larger units (e.g. annual heat input rating of 50 MMBtu/hr or greater, and annual heat input of 220,000 therms or greater) shall comply with Rule 323 by meeting a NOx limit (as seen in San Diego County APCD Rule 69.2). 3. The NOx limits of 42 ppmv for gas fuel-fired operations and 65 ppmv for liquid fuel-fired operations for non-turbine combustion equipment in this rule are not consistent with other jurisdictions limits and are not RACT. Limits in other ozone nonattainment jurisdictions, such as Imperial County APCD Rule 400.2 and Sacramento Metropolitan AQMD, are set at are at 30 ppmv and 40 ppmv for gas and liquid fuel-fired operations. 1 Letter from Doris Lo, U.S. EPA Region 9 to Philip A. McNeely, Maricopa County Air Quality Department, “Re: EPA Comments on the Maricopa County Air Quality Department Rules 323 and 324” dated July 18, 2018. 146 4. Section 306 states that operators may comply with the limits in this rule by installing an ECS, and notes that such systems must be properly operated and maintained in accordance with an approved operations and maintenance plan. The rule language in section 306 could be interpreted to mean that the installation of an ECS on its own would allow compliance with the emission limits. However, an ECS that does not sufficiently reduce emissions could meet section 306’s requirement without any verification for meeting the other section 300 requirements. The effectiveness of such a system in meeting the applicable emission standards is unknown without a compliance determination requirement (which in section 503 only applies to sections 301-304, and only for units larger than 100 million Btu/hr). MCAQD must include language that states that an ECS or combustion control system must also be source tested to confirm compliance with the limit or create parametric monitoring requirements to put in the operation and maintenance plan. Alternatively, the rule language in section 306 should be clarified to not allow for the installation of an ECS to be an alternative to compliance with the RACT limits in sections 301-304. 5. The operations and maintenance plan requirements are only approved by the Control Officer in section 306.3. This constitutes unacceptable director’s discretion. In addition, the rule allows the facility operator to change the operation and maintenance plan in section 306.3.d by submitting changes. MCAQD must revise this language to resolve these enforceability questions, either by removing this discretion, including the EPA in approval of these plans, or outlining clear criteria that must be met for approval. The operation and maintenance plan must include the control equipment manufacturer’s operation and maintenance guidelines. If the MCAQD chooses to revise section 306 so that installation of an emission control system does not result in automatic compliance with the emission limits in sections 301-304, then this discretion may be acceptable as a source test would be the primary determinant of compliance with RACT requirements. 6. Section 503.2 specifies that boilers larger than 100 MMBtu/hr must source test triennially, but does not describe a testing frequency for other units. Other units must be tested at least triennially. MCAQD must also cite the appropriate test method from the list in section 500. 7. Section 200 of this rule and Maricopa’s Rule 100 General Provisions and Definitions does not include a definition for “boiler,” which is used throughout this rule, and in the context of definitions for “annual capacity factor,” “steam generating unit,” and others. For purposes of enforceability, such a definition is necessary. 8. Section 200 also does not include a definition for “continuous emissions monitoring system.” For purposes of enforceability, such a definition is necessary. 147 ADDITIONAL RECOMMENDATIONS FOR THE NEXT RULE REVISION The following revisions were also identified in the July 18, 2018 letter. They are not currently the basis for rule disapproval, but are recommended for the next time the rule is amended. Section 219 defines “steady state” — This is defined as a “safe stable megawatt load”, which is the incorrect measure for non-EGU sources like general ICI sources which may not output power in megawatts. COMMITMENT LETTER CONDITIONS On January 28, 2019, the MCAQD transmitted a letter in response to the EPA’s rule approvability comments made in the course of our evaluation. On February 25, 2019, the ADEQ transmitted the MCAQD letter and committed to submit to EPA rule revisions that will address identified deficiencies. The letters commit to resolve outstanding approvability issues with specific enforceable provisions. The following commitments (in addition to resolving any other approvability issues identified in this TSD) must be met in order for revisions to Rule 323 to be fully approved into the SIP, and to fully meet the RACT SIP requirement for this source category. 1. The MCAQD commits to clarify that the exemptions for emergency fuel use only apply during natural gas curtailments and natural gas emergencies and for up to 36 cumulative hours per year for testing, reliability, training, and maintenance purposes. The MCAQD will add a requirement for the owner or operator to notify the MCAQD when switching to emergency fuel. The MCAQD will also limit the total allowable length of emergency fuel combustion during natural gas curtailments and natural gas emergencies to 168 hours per year per combustion unit (for combustion units located at a major stationary source of nitrogen oxides). 2. The MCAQD commits to implementing current RACT emission limits and RACT tuning procedures for fuel burning equipment located at a major stationary source of NOx. Compliance with the RACT emission limits will be required for: • Stationary gas turbines (rated > 10 MMBtu/hour) • Boilers, steam generating units, and cogeneration steam generating units (rated > 100 MMBtu/hr) • Boilers, steam generating units, and cogeneration steam generating units (rated > 50 MMBtu/hr with usage exceeding 10% of annual capacity) that are located at a major stationary source of NOx. Compliance with RACT tuning procedures will be required for: • Boilers, steam generating units, and cogeneration steam generating units (rated > 10 MMBtu/hr and ≤ 50 MMBtu/hr with annual heat input > 148 220,000 therms) that are located at a major stationary source of NOx. 3. The MCAQD commits to clarify that installation of an ECS or a combustion control system is not an alternative to complying with applicable numeric emission limits. The MCAQD will also clarify that the owner or operator of a combustion unit that is subject to a numeric NOx emission limit must demonstrate compliance by conducting a performance test. The MCAQD will also revise the O&M plan requirements to clarify that the O&M plan must include operating parameters that will be monitored to ensure continued operation of the ECS in the manner the ECS was operated during the performance test. 4. The MCAQD commits to clarify that any owner or operator using an ECS to comply with numeric emission limits must establish parametric monitoring parameters during the required performance test. The MCAQD will clarify that these parametric monitoring parameters shall be included in the O&M plan in order for the Control Officer to approve the O&M plan. The MCAQD will also clarify that the ECS should be operated and maintained according to the manufacturer's specifications (or in accordance with good engineering practices if the manufacturer does not provide maintenance specifications). 5. The MCAQD commits to clarify that all combustion units that are subject to a numeric emission limit must be performance tested to demonstrate compliance with the applicable emission limits. The MCAQD commits to clarify that performance tests must be conducted in accordance with the test methods specified in Section 504 or in accordance with other EPA approved test methods. The MCAQD also commits to requiring performance tests at least once every 5 years for combustion units rated less than 100 million BTU per hour. 6. The MCAQD commits to define the word “boiler” in Rule 323. 7. The MCAQD commits to define “continuous emissions monitoring system” in Rule 323. EPA ACTION Overall, we believe that the revisions are on balance SIP-strengthening. However, the issues described above in the “Rule Deficiencies” section preclude the full approval of this rule into the Arizona SIP. The County and State’s commitment to address these deficiencies and submit a revised rule within one year of our final action of this submittal allows the EPA to conditionally approve the submitted version of Rule 323 into the Arizona SIP. Therefore, we recommend conditionally approving Rule 323 into the SIP. If the EPA approves a revised Rule 323 addressing the deficiencies above, we would be able to certify that Maricopa County is implementing RACT for sources subject to this rule. 149 REFERENCES 1. “Issues Relating to VOC Regulation Cutpoints, Deficiencies, and Deviations,” (a.k.a., Bluebook) EPA OAQPS, May 25, 1988. 2. “Guidance Document for Correcting Common VOC & Other Rule Deficiencies,” (a.k.a., Little Bluebook), EPA Region 9, August 21, 2001. 3. “NOx Emissions from Stationary Gas Turbines,” EPA 453/R-93-007, January 1993. 4. “NOx Emissions from Industrial, Commercial & Institutional Boilers,” EPA453/R- 94-022, March 1994. 5. “De Minimis Values for NOx RACT,” Memorandum from G. T. Helms, Group Leader, Ozone Policy and Strategies Group, U.S. EPA, January 1, 1995. 6. “Cost-Effective Nitrogen Oxides (NOx) Reasonably Available Control Technology (RACT),” Memorandum from D. Ken Berry, Acting Director, Air Quality Management Division, US. EPA, March 16, 1994. 7. “Supplemental Table 1. Major Sources of NOx and VOC in Maricopa County,” attachment to e-mail titled “Maricopa County RACT SIP: EPA Conference Call,” from Johanna Kuspert, Maricopa County Air Quality Department, dated January 3, 2019. 8. Imperial County Air Pollution Control District Rule 400.1, “Stationary Gas Turbine(s) – Reasonably Available Control Technology (RACT)”, as amended February 23, 2010 and submitted to EPA on July 20, 2010. 9. Imperial County Air Pollution Control District Rule 400.2, “Boilers, Process Heaters and Steam Generators”, as amended February 23, 2010 and submitted to the EPA on July 20, 2010. 10. Mojave Desert Air Quality Management District Rule 1159, “Stationary Gas Turbines”, as amended September 28, 2009 and submitted to the EPA on May 17, 2010. 11. Mojave Desert Air Quality Management District Rule 1157, “Boilers & Process Heaters”, as amended May 19, 1997 and submitted to the EPA on August 1, 1997. 12. San Joaquin Valley Air Pollution Control District Rule 4306, “Boilers, Steam Generators, and Process Heaters – Phase 3,” amended on October 16, 2008 and submitted to the EPA on March 17, 2009. 13. San Joaquin Valley Air Pollution Control District Rule 4703, “Stationary Gas Turbines,” amended on September 20, 2007 and submitted to the EPA on March 7, 2008. 14. Ventura County Air Pollution Control District Rule 74.15.1, “Boilers, Steam Generators, and Process Heaters,” amended on June 23, 2015 and submitted to the EPA on November 13, 2015. 15. Ventura County Air Pollution Control District Rule 74.23, “Stationary Gas Turbines,” amended on January 8, 2002 and submitted to the EPA on March 15, 2002. 150 16. Yolo-Solano Air Quality Management District Rule 2.27, “Industrial, Institutional, and Commercial Boilers, Steam Generators, and Process Heaters,” amended August 14, 1996 and submitted to the EPA on October 18, 1996. 17. Yolo-Solano Air Quality Management District Rule 2.34, “Stationary Gas Turbines,” amended November 12, 2014 and submitted to the EPA on June 26, 2015. 151 Return to list of attachments UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION IX AIR DIVISION Technical Support Document for EPA’s Rulemaking for the Arizona State Implementation Plan Maricopa County Air Quality Department Rule 324 Stationary Reciprocating Internal Combustion Engines (RICE) Prepared by: Kevin Gong December 11, 2019 152 RULE IDENTIFICATION Agency Maricopa County Air Quality Department (MCAQD) SIP Approved Rule 324 – Stationary Internal Combustion (IC) Engines Rule Revised – October 17, 2007 Submitted - January 9, 2008 EPA Approved – October 14, 2009 (74 FR 52693) Subject of this Rule 324 – Stationary Reciprocating Internal Combustion TSD Engines (RICE) Revised – November 2, 2016 Submitted – June 22, 2017 Completeness Complete by operation of law – December 22, 2017 Finding BACKGROUND The Maricopa County Air Quality Department (MCAQD) regulates Maricopa County and the cities of Phoenix, Mesa, Scottsdale, Tempe, Chandler, Glendale, as well as 17 other jurisdictions and unincorporated County lands. Part of the area regulated by MCAQD is included in the Phoenix-Mesa area designated as nonattainment for ozone and classified as Moderate for the 2008 8-hour National Ambient Air Quality Standard (NAAQS) (see 40 CFR 81.303, 81 FR 26699). Rule 324, “Stationary Reciprocating Internal Combustion Engines (RICE),” regulates internal combustion engines which are sources of oxides of nitrogen (NOx) emissions. The MCAQD identified four facilities that are both major sources of NOx, and have equipment subject to this rule. Rule 324 was revised as part of the District’s process to ensure that its rules meet the reasonably available control technology (RACT) requirements of Section 182(b) of the Clean Air Act (CAA) for ozone nonattainment areas classified as Moderate. Appendix 1 of the June 22, 2017 submission, Revisions To The State Implementation Plan Revision For The Maricopa County Air Quality Department Ozone Rules Contained In The Arizona SIP, titled Analysis Of Reasonably Available Control Technology For The 2008 8-Hour Ozone National Ambient Air Quality Standard (NAAQS) State Implementation Plan (RACT SIP) (“SIP Analysis”) contains the District’s analysis regarding whether Rule 324 implements RACT levels of control. RULE SUMMARY Rule 324 regulates NOx, volatile organic compound (VOC), sulfur oxide, carbon monoxide, and particulate matter emissions from stationary reciprocating internal combustion engines (RICE). This rule includes emission limits for spark ignition and 153 compression ignition engines rated greater than 250 brake horsepower (bhp), as well as any combination of engines rated greater than 50 bhp if they aggregate to greater than 250 bhp. Rotary engines (including turbines), non-emergency engines operated for performance verification, compressed gas engines used for solar testing and research, engines operated at nuclear power plants for safety reasons, engines used for evaluating engine performance, engines operated 100 hours or less in a calendar year for training purposes, and engines defined are nonroad engines are entirely exempt from this rule. Emergency engines, low-use operations for non-emergency engines, and engines subject to 40 CFR part 63, subpart ZZZZ1 are partially exempt from this rule. The rule also contains related recordkeeping, reporting, and monitoring requirements. Changes from the approved SIP rule include: 1. Clarified applicability to units that are also subject to federal internal combustion engine standards. Engines subject to 40 CFR Part 60 IIII2 and JJJJ3, or 40 CFR Part 63 ZZZZ IC engines operated as non-road engines are exempt or partially exempt from this rule. 2. Definitions were revised, with the definition for “Existing Engine” deleted. 3. Added new restrictions on the sulfur content of fuels, which are met through allowing only ultralow sulfur fuels for combustion. 4. Reorganized the tables of NOx limits for compression and spark ignition engines. New requirements for new engines to comply with applicable federal standards. 5. Added requirements for modified engines to comply with updated limits, and requirements for all engines to install non-resettable totalizing meters. 6. Updated compliance schedules for units that are being removed from service to comply with rule requirements, and for units to install non-resetting totalizing hour meters. 7. Added new compliance determination options for engines that are certified to meet federal requirements in 40 CFR 89, 90, or 1039, and for engines in the same engine family. Engines must be tested at the request of the Control Officer. 8. Additional options for ultralow sulfur diesel fuel verification, and for waste derived fuel gas sulfur verification. 9. An updated list of approved test methods for this rule. 1 National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines. 2 Standards of Performance for Stationary Compression Ignition Internal Combustion Engines. 3 Standards of Performance for Stationary Spark Ignition Internal Combustion Engines. 154 EVALUATION CRITERIA The following criteria were used to evaluate the submitted rule. Enforceability The Bluebook (Issues Relating to VOC Regulation Cutpoints, Deficiencies, and Deviations, EPA, May 25, 1988) and the Little Bluebook (Guidance Document for Correcting Common VOC & Other Rule Deficiencies, EPA Region 9, August 21, 2001) were used to help evaluate compliance with the CAA §110(a)(2)(A) requirement for enforceability. Stringency SIPs must require RACT for each category of sources covered by a Control Technique Guideline (CTG) document as well as each major source of NOx or VOC in ozone nonattainment areas classified as Moderate or above (see sections 182(b)(2) and 182(f)). While there is no CTG for this source category, the MCAQD has identified major sources of NOx covered by this rule within the nonattainment area. Accordingly, the RACT requirement applies to these major sources. The EPA has published an Alternative Control Techniques (ACT) document titled, “NOx Emissions from Stationary Reciprocating Internal Combustion Engines” (EPA 453/R-93-032, July 1993) which describes available control techniques and their estimated costs for internal combustion engines. This ACT and other state and local rules for this category were used to help evaluate Rule 324 against the RACT requirements of CAA §182(b)(2) and §182(f). SIP Relaxation CAA §110(l) prohibits EPA from approving any SIP revision that would interfere with any applicable requirement concerning attainment and reasonable further progress (RFP) or any other applicable requirement of the CAA. In addition, CAA §193 prohibits the modification of any SIP-approved control requirement in effect before November 15, 1990, in a nonattainment area, unless the modification insures equivalent or greater emission reductions. EPA EVALUATION A summary of our evaluation of the three criteria follows. Enforceability Rule 324 applies to stationary reciprocating internal combustion engines (RICE) rated greater than 250 bhp, or a combination of stationary RICE rated greater than 50 bhp used at a source whose aggregated rated bhp is greater than 250 bhp. Engines used for engine research, operated for performance testing, compressed gas engines used for solar testing and research, engines operated as emergency engines at a nuclear power plant, or engines used for training 155 purposes for less than 100 hours per calendar year are exempt from this rule. Engines that are operated as nonroad engines are also exempt. Engines used for backup power, used for emergency pumping, used for lighting airport runways, used for sewage overflow mitigation or prevention, and engines used as non-emergency engine replacement only during engine repairs are partially exempt. We believe that these exemptions describe reasonable emergency circumstances, with the following exceptions: (1) Emergency engines operated for airport runway lighting or sewage overflow prevention could theoretically supplant regular power or an otherwise compliant engine if such operations occurred regularly. (2) On-site emergency engines replacing non-emergency engines during repair should need to either meet the rule’s emission limits or be time-limited in their operation as a replacement. While the definition of “emergency engine” does include a provision stating that operations shall not exceed 500 hours in a calendar year, it is unclear based on the current language if that applies to all emergency engines or just a subset of emergency engine operations. Section 200 includes definitions for terms used in this rule. The definitions for “existing engine” and “new engine” were deleted. The definition for “identical replacement engine” was clarified and strengthened. Previously, such engines that had equal or lower emissions, or met emission control technology requirements were allowed. Now such engines must have equal or lower emissions and also meet control technology requirements. Other definitions were revised or renamed, but are substantially the same. The term “prime engine” was replaced with the term “non-emergency engine,” and the term “internal combustion (IC) engine, stationary” was replaced with the term “stationary internal combustion engine.” Section 300 contains the limits and requirements for controlling emissions from applicable engines. Good combustion practice requirements and tuning procedures are set out in section 302. Alternative tuning procedures are no longer allowed, and handheld monitors may be used by the Control Officer to determine compliance. This revision can improve enforceability, presuming that the technician using the portable analyzer is trained in its use. Recordkeeping requirements in section 500 help to ensure that these tuning and combustion practice requirements are enforceable. The emission limits for existing engines are contained in Table 1 for compression-ignition engines manufactured or modified prior to July 11, 2005, and Table 2 for spark-ignition engines manufactured or modified prior to June 12, 2006. Any units manufactured or modified since then are required to comply with federal standards of performance as set forth in 40 CFR part 60 subparts IIII and JJJJ. These federal requirements for newer engines are also 156 not codified into this rule or any other SIP-approved provision, which are necessary to demonstrate the implementation of RACT for major sources of NOx under CAA section 182(f), and constitutes an approvability issue. Compliance determination for the emission limits set forth in this rule are only required at the request of the Control Officer. This constitutes unacceptable Control Officer discretion. Section 306 allows for engines defined as “equivalent replacement engines” or “identical replacement engines” to be treated as the original engine that was replaced. This provision would be unenforceable as emission reductions from equivalent replacement engines cannot be quantified under this rule’s current requirements. The definition for “equivalent replacement engine” allows for replacement engines that could have a bhp rating up to 20% higher than the engine being replaced so long as the replacement resulted in an emission decrease. Because compliance determination is only required at the request of the Control Officer, emission reductions would be unaccountable, and the requirements would be unenforceable. Section 400 contains compliance schedule requirements for engines being removed from service in order to comply with the rule, or for engines requiring the installation of a non-resetting totalizing hour meter. These provisions are sufficient to ensure compliance with the associated requirements, but as we note above, there is no compliance determination schedule for any other requirements in this rule. Section 500 of the rule contains recordkeeping and reporting requirements for all engines subject to this rule, including requirements for units claiming exemptions. As we note above, each of the compliance determination requirements for emission limits is only required upon request of the Control Officer, without any recurring frequency for tests in engines that are not otherwise certified to meet emission limits (e.g., for units complying with 40 CFR Part 60 Subparts IIII or JJJJ). We find this provision deficient. Other recordkeeping and reporting requirements include operating hours and days of operation for all units, fuel use requirements, records demonstrating the maintenance of good combustion practices, and hourly operations records for units operating under the low use exemption. All records shall be retained for at least 5 years. We find these monitoring, recordkeeping, and reporting requirements are adequate in supporting rule enforceability. Stringency Rule 324 establishes pollution emission limits for engines rated greater than 250 bhp, and for any group of engines rated larger than 50 bhp if their sum output is 250 bhp or greater. It is unclear from the rule text what requirements 157 a group of summed 50 bhp must comply with, as the rule’s emission requirements are only applicable to units greater than 250 bhp. In addition, other air district rules, including Imperial County APCD Rule 400.3 and Ventura County APCD Rule 74.9, are generally applicable to all units down to the 50 bhp threshold. The rule’s limits NOx, VOC, and CO emissions from compression-ignition engines and spark-ignition engines, are laid out in Tables 1 and 2. However, compression-ignition engines manufactured or modified after July 11, 2005, and spark-ignition engines manufactured or modified after June 12, 2006, must comply with the applicable New Source Performance Standards in 40 CFR part 60. The MCAQD must demonstrate that these federal requirements are appropriate as RACT, as RACT may constitute emission limits, control technology, or operational requirements that are more stringent than the federal standards, which apply nationally, including in areas determined to be in attainment. SIP Relaxation Many of the provisions in this rule are unchanged or more stringent than the SIP approved rule. Therefore, we find that the rule revisions are consistent with CAA sections 110(l) and 193. RULE DEFICIENCIES The following deficiencies were identified in a letter dated July 18, 2018, and preclude full approval of the rule into the SIP:4 1. The submitted rule’s current structure of applicability and emission limits does not clearly outline a RACT limit for NOx and VOC emissions from all applicable IC engines. The MCAQD should review similar source category regulations in other jurisdictions (San Diego APCD Rule 69.4 and Yolo-Solano AQMD Rule 2.32) on how they structure clearer RACT limits that may include similar or more stringent requirements or limits for engines otherwise subject to federal requirements and standards in 40 CFR part 60, subparts IIII and JJJJ. We understand that units may need to comply with more stringent Federal standards in some cases, but a RACT limit would not interfere with a facility’s compliance with a more stringent limit. The Clean Air Act requires that RACT limitations be approved into the Federally- enforceable SIP. It is inappropriate to rely on requirements outside of the SIP, such as NSPS standards found in 40 CFR Part 60. 4 Letter from Doris Lo, U.S. EPA Region 9 to Philip A. McNeely, Maricopa County Air Quality Department, “Re: EPA Comments on the Maricopa County Air Quality Department Rules 323 and 324” dated July 18, 2018. 158 2. The submitted rule only applies to engines rated greater than 250 bhp, and to engines greater than 50 bhp when operating at a facility whose units sum to greater than 250 bhp. The MCAQD should lower the applicability threshold to 50 bhp to be in line with other jurisdictions’ RACT rules. The current rule also does not clearly state compliance requirements for 50 bhp engines summed at a 250 bhp facility. The following deficiencies were identified in a letter dated July 1, 2019, and also preclude full approval of the rule into the SIP:5 3. The submitted rule allows for flexibility in the treatment of replacement engines. In section 104.6, emergency engines that serve as backup to replace non- emergency engines may do so until the non-emergency engine is repaired, but this time span is otherwise unbounded, and may operate above RACT limits. The MCAQD should restrict the amount of time allowed to operate that emergency engine, or the backup engine should be required to meet RACT limits. Current rule provisions in sections 207 and 306 also allow for engines that are deemed equivalent or identical to replace existing engines to be treated the same as the engine being replaced, but there are no requirements for replacement engines to quantify emissions equivalency or reductions. 4. The submitted rule does not specify a compliance determination interval for engines, beyond at the Control Officer’s discretion. This provision is found in section 501.1b. ADDITIONAL RECOMMENDATIONS FOR THE NEXT RULE REVISION The following revisions were also identified in the July 18, 2018 letter. They are not currently the basis for rule disapproval, but are recommended for the next time the rule is amended. 1. Section 103.1(e) exempts stationary engines at a nuclear power plant used for safety reasons. Please describe the engines used at these facilities and explain why such plants cannot use compliant engines for safety applications. 2. Section 104 and section 205 provide special considerations for emergency engines. Please explain why these engines need special consideration, when these engines already exist on site. Please characterize the number of sources that have non-compliant engines and would qualify under these partial exemptions. 5 Letter from Doris Lo, U.S. EPA Region 9 to Philip A. McNeely, Maricopa County Air Quality Department, “Re: Additional EPA Comments on Maricopa County Air Quality Department Rule 324” dated July 1, 2019. 159 3. Section 105 describes a low use threshold that varies between 100-200 hours per year depending on whether the engine is above or below a 1000 bhp threshold. How many engines are in each size class, and why is this threshold a reasonable cut-point? 4. Section 103.1.g exempts stationary engines used for training purposes. The term “training” is undefined. Please define what activities constitute valid training with respect to engines in this context. COMMITMENT LETTER CONDITIONS On January 28, 2019, the MCAQD transmitted a letter in response to the EPA’s rule approvability comments made in the course of our evaluation. On February 25, 2019, the ADEQ transmitted the MCAQD letter and committed to submit to the EPA rule revisions that will address identified deficiencies. The letter committed to resolve the following outstanding approvability issues with specific enforceable provisions. 1. The MCAQD commits to restructure the rule to clarify applicability and emission limits. The MCAQD will retain existing SIP requirements for stationary RICE that are not located at a major stationary source of nitrogen oxides. The MCAQD will retain the existing numeric emission limits in SIP Rule 324 for non-emergency engines that are located at a major stationary source of nitrogen oxides (because these limits are consistent with RACT limits in other jurisdictions). 2. The MCAQD commits to lower the applicability threshold to 50 bhp for stationary RICE located at a major source of nitrogen oxides. The MCAQD will also clarify what emission limits apply to non-emergency engines rated above 50 bhp that are located at a major stationary source of nitrogen oxides. We received an additional commitment letter from the MCAQD on December 5, 2019, to address the deficiencies identified in our July 1, 2019 comment letter. The following commitments must be met in order for revisions to Rule 324 to be fully approved into the SIP, and to meet the RACT SIP requirement for the source category. 3. The MCAQD commits to clarify constraints on the amount of time an emergency engine can be used to replace a non-emergency engine, and to clarify the definition for “emergency engine”. 4. The MCAQD commits to remove the provisions allowing for equivalent engines to be treated as the original engine without proper source testing or emissions verification procedures. 5. The MCAQD commits to include compliance determination intervals for non- emergency engines located at both major sources and for those not located at major sources. 160 All of the commitments listed above must be met in order for revisions to Rule 324 to be fully approved into the SIP, and to meet the RACT SIP requirement for these sources at major sources of NOx in Maricopa County. EPA ACTION The issues described above in the “Rule Deficiencies” section preclude the full approval of this rule into the Arizona SIP. The MCAQD and ADEQ’s commitment to address these deficiencies and submit a revised rule within one year of our final action of this submittal would allow the EPA to conditionally approve the submitted version of Rule 324 into the Arizona SIP. If the EPA approves a revised Rule 324 addressing the deficiencies above, we would be able to certify that the MCAQD is implementing RACT for sources subject to this rule. REFERENCES 1. “Issues Relating to VOC Regulation Cutpoints, Deficiencies, and Deviations,” (a.k.a., Bluebook) EPA OAQPS, May 25, 1988. 2. “Guidance Document for Correcting Common VOC & Other Rule Deficiencies,” (a.k.a., Little Bluebook), EPA Region 9, August 21, 2001. 3. NOx Emissions from Stationary Reciprocating Internal Combustion Engines,” EPA 453/R-93-032, July 1993. 4. “De Minimis Values for NOx RACT,” Memorandum from G. T. Helms, Group Leader, Ozone Policy and Strategies Group, U.S. EPA, January 1, 1995. 5. “Cost-Effective Nitrogen Oxides (NOx) Reasonably Available Control Technology (RACT),” Memorandum from D. Ken Berry, Acting Director, Air Quality Management Division, US. EPA, March 16, 1994. 6. “Supplemental Table 1. Major Sources of NOx and VOC in Maricopa County,” attachment to e-mail titled “Maricopa County RACT SIP: EPA Conference Call,” from Johanna Kuspert, Maricopa County Air Quality Department, dated January 3, 2019. 7. Imperial County Air Pollution Control District Rule 400.3, “Internal Combustion Engine(s),” as adopted on November 22, 2013 and submitted to EPA on February 10, 2014. 8. San Diego County Air Pollution Control District Rule 69.4, “Stationary Reciprocating Internal Combustion Engines,” amended on July 30, 2003 and submitted to the EPA on November 4, 2003. 9. Ventura County Air Pollution Control District Rule 74.9, “Stationary Internal Combustion Engines,” amended on November 8, 2055 and submitted to the EPA on March 10, 2006. 10. Yolo-Solano Air Quality Management District Rule 2.32, “Stationary Internal Combustion Engines,” amended on October 10, 2001 and submitted to the EPA on November 28, 2001. 161