Z2020101 BOS REPORT.PDF

Maricopa County — Formal (2021-04-21)

View PDF Item 8 Meeting page

Extracted text (via pymupdf_layout) 65533 characters
Report to the Board of Supervisors
Prepared by the Maricopa County Planning and Development Department
Board Hearing Date: April 21, 2021
Case #/Title: Z2020101 – Wickenburg Ranchos
Supervisor District: 4
Applicant/Owner: Joseph Levie, SAC Wireless on behalf of AT&T / Caballeros Inn
& Ranch Co.
Request: Special Use Permit (SUP) for a wireless communication facility
in the Rural-43 zoning district
Site Location: Generally located 780’ southwest of the SWC of Vulture Mine
Rd. and Maguire Dr. in the Wickenburg area.
Site Size: Approx. 618 sq. ft. (of an approx. 112-acre parcel)
County Island Status: N/A
Additional
Comments: The requested SUP is for a wireless facility with a 49’ (h)
monopole located at the Caballeros Inn and Ranch in
Wickenburg. The SUP also includes details for removal of an
existing 40’ (h) monopole adjacent to the proposed
monopole. Staff is recommending an 18-year timeframe for
SUP entitlement as requested by the applicant.
There are no outstanding concerns from reviewing agencies.
The site is within the Town of Wickenburg Municipal Planning
Area, the Town of Wickenburg was notified and as of the date
of this report, staff have not received comments from the City
concerning this request. All property owners within 300’ and
interested parties of the site were notified; however, as of the
date of this report no support or opposition has been
received.
Commission
Recommendation: On 3/25/2021, the Commission voted 9-0 to recommend
approval of Z2020101 subject to conditions ‘a’ – ‘g’:
a. Development of the site shall be in substantial conformance with the Site Plan
entitled “FirstNet Wickenburg Ranchos”, consisting of 17 full-size sheets, dated
stamped received on February 16, 2021, except as modified by the following
conditions.
April 21, 2021
Z2020101
Page 1 of 2

b. Development of the site shall be in substantial conformance with the Narrative
Report entitled “Commnet-Wickenburg Ranchos”, consisting of 3 pages, stamped
received February 16, 2021, except as modified by the following conditions.
c. The following SUP standards shall apply:
1. The maximum height of the Wireless Communication Facility shall be limited
to 49’, including all attachments and lighting rod.
2. The maximum diameter of the tower shall not exceed 34 inches.
3. The barbed-wire chain link fence with privacy slats shall be allowed as
screening for the facility.
d. A Minor Amendment shall be required to co-locate future carriers on the Wireless
Communication Facility.
e. This Special Use Permit shall expire 18 years from the date of approval by the Board
of Supervisors on April 21, 2039, or termination of the use for a period of 90 or more
days, whichever occurs first. All of the site improvements shall be removed within
120 days of such termination or expiration.
f. Noncompliance with any Maricopa County Regulation shall be grounds for
initiating a revocation of this Special Use Permit as set forth in the Maricopa County
Zoning Ordinance.
g. The granting of this change in use of the property has been at the request of the
applicant, with the consent of the landowner. The granting of this approval allows
the property to enjoy uses in excess of those permitted by the zoning existing on
the date of application, subject to conditions. In the event of the failure to comply
with any condition, and at the time of expiration of the Special Use Permit, the
property shall revert to the zoning that existed on the date of application. It is,
therefore, stipulated and agreed that either revocation due to the failure to
comply with any conditions, or the expiration of the Special Use Permit, does not
reduce any rights that existed on the date of application to use, divide, sell or
possess the property and that there would be no diminution in value of the
property from the value it held on the date of application due to such revocation
or expiration of the Special Use Permit. The Special Use Permit enhances the value
of the property above its value as of the date the Special Use Permit is granted
and reverting to the prior zoning results in the same value of the property as if the
Special Use Permit had never been granted.
Presented by: Ray Banker, Senior Planner
Reviewed by: Darren Gérard, AICP, Planning Services Manager
Attachment: 3/25/21 P&Z Packet (29 pages)
Note: 3/25/21 Draft P&Z Minutes are not available as of the writing of this report, but can
be provided upon request later when available.
April 21, 2021
Z2020101
Page 2 of 2

Report to the Planning and Zoning Commission
Prepared by the Maricopa County Planning and Development Department
Case: Z2020101 – Wickenburg Ranchos
Hearing Date: March 25, 2021
Supervisor District: 4
Applicant: Joseph Levie, SAC Wireless on behalf of AT&T
Owner: Caballeros Inn & Ranch Co.
Request: Special Use Permit (SUP) for a wireless communication facility in the
Rural-43 zoning district
Site Location: Generally located 780’ southwest of the SWC of Vulture Mine Rd.
and Maguire Dr. in the Wickenburg area.
Site Size: Approx. 618 sq. ft. (of an approx. 112-acre parcel)
Density: N/A
County Island: N/A
County Plan: Rural Densities (0 – 1 d.u./ac.)
Municipal Plan: Wickenburg General Plan 2025 – Resort/Health Facility
Municipal Comments: None received
Support/Opposition: None known
Recommendation: Approve with conditions
Z2020101
Page 1 of 6

Project Summary:
1. SAC Wireless on behalf of AT&T is requesting an 18-year Special Use Permit (SUP) for a
wireless communication facility (WCF) within the Rural-43 zoning district. The 112-acre
subject site is known as Rancho de los Caballeros or Caballeros Inn and Ranch, a guest
ranch that has Legal Non-Conforming status through case LU20130024. The ranch
property is a triangular piece of land that includes several parcels along the east side of
Vulture Mine Road. The proposed WCF would be located on the southernmost parcel of
the ranch. Outside of the rest of the ranch property to the north, there is vacant Arizona
State Land Department property to the west, south, and east of the site.
2020 Aerial Photographs of Rancho de los Caballeros and proposed location of WCF
Z2020101
Page 2 of 6

2. The applicant will be leasing a 618-square foot area to house the WCF. The facility would
consist of a 45’ (h) monopole with ultimate height of 49’ (h) including appurtenance.
There is an existing 40’ (h) tower in the same location that would be replaced by the
proposed tower. The area would also have related equipment to be located within the
existing fenced area. The tower would include two sectors of panel antennas (for
Commnet and AT&T) as well as a relocated microwave dish below the antennas. The 49’
structure would be set back from the closest property boundary to the north by at least
245’. The WCF would meet the setback requirements for Rural-43 which state the
following under Article 1202.3.1.1.g: “Wireless communication facilities shall be setback 2
feet from all property lines for each 1 foot in height.” The WCF would also not exceed the
maximum height limit of 80 per MCZO Article 1202.3.1.a.
3. This SUP is being requested since the proposed tower structure would exceed the
maximum diameter of 30 inches (MCZO Article 1202.3.1.c) at 34 inches. The provided
justification is for safety concerns by making the tower more structurally sound. The other
request for deviations from the standards is for the minimum 6’ (h) solid wall per MCZO
Article 1202.3.1.l. The applicant is requesting that the existing approx. 7’ (h) barbed wire
fencing with privacy slats be allowed to screen the compound. This fenced in area also
includes existing water tanks and a pump station building.
Z2020101 Zoning Map
Z2020101
Page 3 of 6

Proposed Elevation Details (left) Existing to be Removed Tower Elevations (right)
Existing On-Site and Adjacent Zoning / Land Use:
4. On-site: Rural-43 / Guest Ranch
North: Rural-43 / Guest Ranch
South: Rural-43 (State Trust Land) / Vacant
East: Rural-43 (State Trust Land) / Vacant
West: Arterial / Vulture Mine Road
Utilities and Services:
5. Water: Caballeros Water Co.
Wastewater: Caballeros Water Co.
School District: Wickenburg Unified School District
Fire: Wickenburg Volunteer Fire District
Police: Maricopa County Sheriff’s Office
Adopted Plans:
6. Vision 2030 Comprehensive Plan: The property is designated as “Rural” (0-1 d.u./ac.).
7. Wickenburg 2025 General Plan: The Property is designated for “Resort/Health Facility”.
Z2020101
Page 4 of 6

Public Participation Summary
8. The applicant complied with the Maricopa County Citizen Review Process with the
required posting of the property and notification by first class mail to adjacent property
owners within 300’ of the subject parcel and interested parties. Furthermore, the initial
submittal was routed to the Town of Wickenburg who has not responded. As of the date
of this report, staff has not received any letters of opposition.
Outstanding Concerns from Reviewing Agencies:
9. N/A
Staff Analysis:
10. Staff believes that the SUP is both reasonable and necessary to maintain and provide
increased expanded coverage in this rural area. There would be significant separation
between the proposed WCF and the adjacent properties. It will be located within an
existing ranch with services provided to guests of the ranch. The proposed would also
replace an existing wireless tower at the same location. Although the new tower would
be larger in height (9’ taller) than the existing, the 49’ (h) is well below the allowed 80’ (h)
maximum per the zoning ordinance. Furthermore, as of the date of this report, neither the
applicant nor staff has received opposition as a result of the applicant’s citizen
participation outreach efforts.
Recommendation:
11. For the reasons outlined in this report, staff recommends the Commission motion for
Approval of Z2020101, subject to conditions ‘a’ – ‘g’.
a. Development of the site shall be in substantial conformance with the Site Plan
entitled “FirstNet Wickenburg Ranchos”, consisting of 17 full-size sheets, dated
stamped received on February 16, 2021, except as modified by the following
conditions.
b. Development of the site shall be in substantial conformance with the Narrative
Report entitled “Commnet-Wickenburg Ranchos ”, consisting of 3 pages,
stamped received February 16, 2021, except as modified by the following
conditions.
c. The following SUP standards shall apply:
1. The maximum height of the Wireless Communication Facility shall be limited
to 49’, including all attachments and lighting rod.
2. The maximum diameter of the tower shall not exceed 34 inches.
3. The barbed-wire chain link fence with privacy slats shall be allowed as
screening for the facility.
d. A Minor Amendment shall be required to co-locate future carriers on the Wireless
Communication Facility.
Z2020101
Page 5 of 6

e. This Special Use Permit shall expire 18 years from the date of approval by the Board
of Supervisors on April 21, 2039, or termination of the use for a period of 90 or more
days, whichever occurs first. All of the site improvements shall be removed within
120 days of such termination or expiration.
f. Noncompliance with any Maricopa County Regulation shall be grounds for
initiating a revocation of this Special Use Permit as set forth in the Maricopa County
Zoning Ordinance.
g. The granting of this change in use of the property has been at the request of the
applicant, with the consent of the landowner. The granting of this approval allows
the property to enjoy uses in excess of those permitted by the zoning existing on
the date of application, subject to conditions. In the event of the failure to comply
with any condition, and at the time of expiration of the Special Use Permit, the
property shall revert to the zoning that existed on the date of application. It is,
therefore, stipulated and agreed that either revocation due to the failure to
comply with any conditions, or the expiration of the Special Use Permit, does not
reduce any rights that existed on the date of application to use, divide, sell or
possess the property and that there would be no diminution in value of the
property from the value it held on the date of application due to such revocation
or expiration of the Special Use Permit. The Special Use Permit enhances the value
of the property above its value as of the date the Special Use Permit is granted
and reverting to the prior zoning results in the same value of the property as if the
Special Use Permit had never been granted.
Presented by: Ray Banker, Planner
Reviewed by: Matthew Holm, AICP, Planning Supervisor
Attachments: Case Map (1 page)
Site Plan (reduced 8.5”x11”, 17 pages)
Narrative Report (3 pages)
Engineering Comments (1 page)
MCESD comments (1 page)
Z2020101
Page 6 of 6

MARICOPA COUNTY
Application Name: Wickenburg Ranchos EDR
Legal Description
, T7N R05W 21
Applicant Applicant Phone/Email
Joseph Levie 312.858.9024 joseph.levie@sacw.com Z2020101
Case Address Parcel Primary:
505-44-005X
Generated March 7, 2021 23:57 PM Gross Acres: 0.01 approx. Map scale 1:12,423
Supervisor District No. 4
SUP FOR A NEW WIRELESS COMMUNICATIONS FACILITY
Maricopa County Planning & Development - Phoenix, AZ /

PROJECT: FIRSTNET
SITE NUMBER: AZL02819A Connecting Rural America
FA #: 15061893 TM
PACE #: MRANM031869
5015 SHOREHAM PLACE, SUITE 150
SITE NAME: WICKENBURG RANCHOS SAN DIEGO, CA 92122
www.sacw.com
ADDRESS: 1551 SOUTH VULTURE MINE RD Connecting Rural America
WICKENBURG, AZ 85390
· COLOR OF POLE AND EQUIPMENT TO BE APPROVED 604 FOX GLEN
CASE NUMBER: Z2020101 BY MARICOPA COUNTY BEFORE CONSTRUCTION BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
· NO NEW FENCING REQUIRED AS PART OF PROJECT
FAX : 847.277.0080
ae@westchesterservices.com
PROJECT INFORMATION LOCATION MAP SCOPE OF WORK DRAWING INDEX
SITE NAME: WICKENBURG RANCHOS AT&T PROPOSES TO: SHEET DESCRIPTION
SITE NUMBER: AZL02819A NOTE: ALL WORK WILL BE WITHIN EXISTING TELECOMMUNICATION FACILITY COMPOUND. JOHN M. BANKS
SITE ADDRESS: 1551 SOUTH VULTURE MINE RD NO EXPANSION REQUIRED. T-1.0 TITLE SHEET
WICKENBURG, AZ 85390 · REMOVE EXISTING EQUIPMENT PRIOR TO DEMOLITION, PER PLAN ARCHITECT
· INSTALL (3) PROPOSED AT&T PANEL ANTENNAS A-1.0 OVERALL PARCEL PLAN
JURISDICTION: MARICOPA COUNTY
COUNTY: MARICOPA · INSTALL (3) PROPOSED AT&T RADIOS (AHLBA) A-1.1 OVERALL SITE PLAN
PROHIBITED. · INSTALL (3) PROPOSED AT&T RADIOS (AHFIB)
TOWER OWNER: COMMNET
· INSTALL (1) PROPOSED AT&T ANTENNA & RRU RING MOUNT W/ MOUNTING PIPES A-1.2 SITE PLAN
LATITUDE: 33.9383049 · INSTALL (1) PROPOSED AT&T DC9 SURGE SUPPRESSOR
LONGITUDE: -112.7796936 A-2.0 AT&T PROPOSED ANTENNA & EQUIPMENT PLANS
· INSTALL (1) PROPOSED AT&T DC12 SURGE SUPPRESSOR
STRICTLY A.A.A. : 505-44-005X · INSTALL (1) PROPOSED AT&T FIBER TRUNK 24 PAIR CABLE A-2.1 COMMNET PROPOSED ANTENNA & EQUIPMENT PLANS
ZONING: RU-43 SITE · INSTALL (3) PROPOSED AT&T DC TRUNK CABLES
IS PROPOSED USE: UNMANNED TELECOMMUNICATION · INSTALL (1) PROPOSED AT&T DELTA 2-BAY EQUIPMENT CABINET A-3.0 EXISTING & PROPOSED ELEVATIONS REVISIONS
FACILITY · INSTALL (1) PROPOSED AT&T ICE-BRIDGE REV. DATE DESCRIPTION INITIALS
A-4.0 AT&T EQUIPMENT DETAILS & SPECIFICATIONS
SERVICES PARCEL SIZE: 111.90 ACRES (4,874,566 SF) · INSTALL (1) PROPOSED AT&T 8'-0"X7'-6" CONCRETE EQUIPMENT PAD A 07/10/20 90% CD FOR REVIEW LJ
· INSTALL (1) PROPOSED AT&T H-FRAME A-4.1 AT&T EQUIPMENT DETAILS & SPECIFICATIONS
B 09/16/20 90% CD FOR REVIEW YH
· INSTALL (1) PROPOSED AT&T METER W/ MAIN SERVICE BREAKER
CARRIER PROPERTY OWNER: CABALLEROS INN & RANCH CO · INSTALL (1) PROPOSED AT&T ELECTRICAL PANEL A-4.2 AT&T EQUIPMENT DETAILS & SPECIFICATIONS C 10/16/20 90% CD FOR REVIEW YH
1551 SOUTH VULTURE MINE RD · INSTALL (1) PROPOSED AT&T FIBER BOX A-4.3 AT&T EQUIPMENT DETAILS & SPECIFICATIONS D 12/02/20 90% CD FOR REVIEW YH
TO WICKENBURG, AZ 85390 · INSTALL (1) PROPOSED AT&T OUTDOOR GFCI OUTLET
A-4.4 COMMNET EQUIPMENT DETAILS & SPECIFICATIONS E 01/07/21 90% CD FOR REVIEW DWM
RELATES A-4.5 COMMNET EQUIPMENT DETAILS & SPECIFICATIONS F 02/09/21 90% CD FOR REVIEW YH
AT&T PROJECT MANAGER: ANTHONY V. DROSI
COMMNET PROPOSES TO: E-1.0 AT&T 1-LINE DIAGRAM
WHICH PROJECT MANAGER-ALTERNATE · REMOVE EXISTING 40'-0" MONOPOLE TOWER
BUILD MODEL · INSTALL PROPOSED 45'-0" MONOPOLE TOWER ON NEW 6'-0" CONCRETE FOOTING, PER PLAN G-1.0 AT&T EQUIPMENT & ANTENNA GROUNDING PLANS
THAT AT&T MOBILITY NORTH · INSTALL (1) PROPOSED COMMNET ICE BRIDGE
G-1.1 COMMNET EQUIPMENT & ANTENNA GROUNDING PLANS
7337 TRADE ST., RM 3684 · INSTALL (1) PROPOSED COMMNET ANTENNA & RRU RING MOUNT W/ MOUNTING PIPES
THAN SAN DIEGO, CA 92121-4202 · RELOCATE (1) EXISTING COMMNET FTTA BOX G-2.0 GROUNDING NOTES & DETAILS
OFFICE: (858) 886-1255 VICINITY MAP · RELOCATE (3) EXISTING COMMNET ANTENNAS ON NEW MONOPOLE TOWER, PER PLAN
OTHER MOBILE: (858) 337-7968 · RELOCATE (3) EXISTING COMMNET RADIOS ON NEW MONOPOLE TOWER, PER PLAN
COMMNET PROJECT MANAGER: POLLY PATRICK
DISCLOSURE OFFICE: (720) 733-5399
MOBILE: (303) 628-2034
EMAIL: ppatrick@atni.com
OR
APPLICANT: SAC WIRELESS NOT FOR CONSTRUCTION UNLESS APPROVED BY JURISDICTION
USE
ON BEHALF OF AT&T
ANY PRESTON FORD GENERAL NOTES
SITE
623-256-2704 DRIVING DIRECTIONS "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. preston.ford@sacw.com THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
WILL VISIT THE SITE AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY DIRECTIONS FROM WICKENBURG MUNICIPAL AIRPORT: WILL NOT RESULT IN ANY SIGNIFICANT DISTURBANCE OR EFFECT ON DRAINAGE; THE STATE OF ARIZONA"
PROJECT TEAM NO SANITARY SEWER SERVICE REQUIRED AND NO COMMERCIAL SIGNAGE IS
1. HEAD SOUTHEAST TOWARD W WICKENBURG WAY
PROPOSED.
PROPRIETARY 2. TURN LEFT ONTO W WICKENBURG WAY FIRSTNET
ARCHITECT:
3. TURN RIGHT ONTO N VULTURE MINE RD WICKENBURG RANCHOS
JOHN M. BANKS ARCHITECT
4. TURN LEFT ONTO N 334TH AVE DO NOT SCALE DRAWINGS
IS JOHN BANKS AZL02819A
5. TURN RIGHT ONTO VULTURE PEAK RD
604 FOX GLEN 1551 SOUTH VULTURE MINE RD
DESTINATION WILL BE ON THE LEFT CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & FIELD
DOCUMENTS BARRINGTON, IL 60010 WICKENBURG, AZ 85390
CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ARCHITECT
CONTACT: JOHN BANKS
OR ENGINEER OF RECORD IN WRITING OF ANY DISCREPANCIES BEFORE
PHONE: (847) 277-0070
PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR THE SAME. SHEET TITLE
EMAIL: jbanks@westchesterservices.com
CONSTRUCTION
PLANNING/ZONING CONSULTANT: NORTH PROJECT NOTES
SPECIAL NOTES
SAC WIRELESS FCC:
OF PRESTON FORD EVERY WIRELESS TELECOMMUNICATIONS FACILITY SHALL MEET THE TITLE SHEET
SET 623-256-2704 1. ALL WORK SHALL BE INSTALLED IN ARCHITECT OR ENGINEER OF RECORD IN REGULATIONS OF THE FCC REGARDING PHYSICAL AND ELECTROMAGNETIC
preston.ford@sacw.com TO OBTAIN LOCATION OF PARTICIPANTS CONFORMANCE WITH CURRENT CARRIER WRITING OF ANY DISCREPANCIES BEFORE INTERFERENCE. THE ONLY SIGNAGE WHICH IS PERMITTED IS THAT WHICH IS
THIS UNDERGROUND FACILITIES BEFORE YOU DIG IN CONSTRUCTION INSTALLATION GUIDE. PROCEEDING WITH THE WORK OR BE REQUIRED BY STATE OR FEDERAL LAW.
IN ARIZONA, CALL ARIZONA 811 2. EXISTING CONDITIONS WILL BE VERIFIED IN
CONSTRUCTION MANAGER: FIELD. IF SIGNIFICANT DEVIATIONS OR RESPONSIBLE FOR THE SAME.
4. THESE DRAWINGS ARE FULL SIZE & CODE COMPLIANCE
CONTAINED SAC WIRELESS R DETERIORATION ARE ENCOUNTERED AT THE
SCALEABLE ON 22"X34" SHEET SIZE & ARE NOT
RANDY HEATH TOLL FREE: 1-800-782-5348 OR TIME OF CONSTRUCTION, A REPAIR PERMIT REDUCED IN SIZE. · 2012 INTERNATIONAL BUILDING CODE SHEET NUMBER
2810 S. ROOSEVELT STREET www.arizona811.com WILL BE OBTAINED & CONTRACTOR SHALL · 2012 INTERNATIONAL RESIDENTIAL CODE
5. STATEMENT THAT COMPLIANCE WITH THE
TEMPE, AZ 85282 NOTIFY ARCHITECT OR ENGINEER OF RECORD · 2012 INTERNATIONAL MECHANICAL CODE
ARIZONA STATUTE REQUIRES MIN OF 2 IMMEDIATELY. ENERGY CODE IS NOT REQUIRED. -SCOPE OF · 2012 INTERNATIONAL PLUMBING CODE
INFORMATION PHONE: (480) 370-3069 WORK DOES NOT INVOLVE MODIFICATIONS TO · 2012 INTERNATIONAL FUEL GAS CODE T-1.0
WORKING DAYS NOTICE BEFORE YOU 3. CONTRACTOR SHALL VERIFY ALL PLANS &
EMAIL: randy.heath@sacw.com Know what's below. EXTERIOR ENVELOPE OF BUILDING, HVAC · 2012 INTERNATIONAL EXISTING BUILDING CODE
EXCAVATE (DAY OF THE CALL NOT INCLUDED) EXISTING DIMENSIONS & CONDITIONS ON THE SYSTEMS OR ELECTRICAL LIGHTING. · 2012 INTERNATIONAL ENERGY CONSERVATION CODE
Call before you dig. JOB SITE & SHALL IMMEDIATELY NOTIFY THE · 2017 NATIONAL ELECTRIC CODE
THE

Connecting Rural America
EXISTING PARCEL LINES
FOR PARCEL #505-44-005X
TM
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
www.sacw.com
604 FOX GLEN
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
FAX : 847.277.0080
ae@westchesterservices.com
JOHN M. BANKS
ARCHITECT
PROHIBITED.
STRICTLY
IS ±260.8' REVISIONS
REV. DATE DESCRIPTION INITIALS
SERVICES ±245.1' A 07/10/20 90% CD FOR REVIEW LJ
B 09/16/20 90% CD FOR REVIEW YH
PROPOSED NEW 45'-0" MONOPOLE
CARRIER TOWER ON NEW CONCRETE FOOTING C 10/16/20 90% CD FOR REVIEW YH
D 12/02/20 90% CD FOR REVIEW YH
TO
E 01/07/21 90% CD FOR REVIEW DWM
RELATES F 02/09/21 90% CD FOR REVIEW YH
WHICH
THAT
THAN
OTHER
DISCLOSURE
OR
USE
ANY
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
PROPRIETARY
FIRSTNET
WICKENBURG RANCHOS
IS AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
SHEET TITLE
CONSTRUCTION
OF OVERALL PARCEL PLAN
SET
THIS
IN
CONTAINED
SHEET NUMBER
INFORMATION A-1.0
NORTH
SCALE
THE OVERALL PARCEL PLAN 1
N.T.S.

DISCLAIMER
· THIS SITE PLAN WAS GENERATED WITHOUT
THE BENEFIT OF A CURRENT SURVEY OR
ANY SURVEY. LOCATIONS OF PROPERTY
LINES AND UTILITIES ARE PRELIMINARY.
Connecting Rural America
TM
EXISTING TRANSFORMER
(AT&T POWER P.O.C.)
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
EXISTING ACCESS www.sacw.com
GATE (TYP)
EXISTING TRANSFORMER
PROPOSED AT&T ON CONCRETE PAD
POWER ROUTE (±25')
604 FOX GLEN
ALPHA EXISTING EXISTING BARRINGTON, IL 60010
30° BUILDING BUILDING TELEPHONE: 847.277.0070
@ FAX : 847.277.0080
ae@westchesterservices.com
PROPOSED SECTOR
EXISTING ACCESS
GATE (TYP)
PROPOSED COMMNET JOHN M. BANKS
PROPOSED 45'-0" MONOPOLE TOWER 438 SF LEASE AREA
1/2" ARCHITECT
ON NEW 6'-0" DIA CONCRETE FOOTING EXISTING 40'-0" MONOPOLE TOWER EXISTING CONCRETE PAD
37'-7
TO BE DISASSEMBLED AND REMOVED
PROPOSED AT&T FIBER ROUTE
PROHIBITED. PROPOSED 1" Ø PVC CONDUIT
43'-7"
EXISTING ABOVE GROUND
WATER PIPE
EXISTING COMMNET H-FRAME
STRICTLY 13'-0"
19'-9" EXISTING CONCRETE PAD
IS EXISTING COMMNET EQUIPMENT TO REVISIONS
11'-5" REMAIN (TYP) 15'-0" 11'-5" EXISTING WATER TANK REV. DATE DESCRIPTION INITIALS
14'-9"
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
EXISTING METAL PLATFORM WITH EXISTING METAL PLATFORM WITH B 09/16/20 90% CD FOR REVIEW YH
CONCRETE BLOCKS TO REMAIN CONCRETE BLOCKS TO REMAIN
CARRIER C 10/16/20 90% CD FOR REVIEW YH
19'-9"
D 12/02/20 90% CD FOR REVIEW YH
TO 12'-2"
12'-3" 14'-9" EXISTING WATER TANK E 01/07/21 90% CD FOR REVIEW DWM
RELATES EXISTING UNDERGROUND EXISTING PUMP STATION F 02/09/21 90% CD FOR REVIEW YH
WATER PIPE (TYP) EXISTING PUMP BUILDING
WHICH STATION BUILDING EXISTING UNDERGROUND
WATER PIPE
EXISTING COMMNET FIBER CABINET
THAT (AT&T FIBER P.O.C.) (VIF)
THAN EXISTING COMMNET GENERATOR
EXISTING ABOVE
OTHER EXISTING UNDERGROUND GAMMA WATER PIPE 55'-2"
240° EXISTING CHAIN-LINK FENCE
WATER PIPE
PROPOSED @ W/BARBED WIRE AND PRIVACY
DISCLOSURE SECTOR EXISTING WATER TANK SLATS 57'-1"
SECTOR PROPOSED
OR
@
USE BETA EXISTING WATER TANK
150°
ANY
EXISTING CHAIN-LINK FENCE W/BARBED "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. EXISTING COMMNET LEASE AREA BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
WIRE AND PRIVACY SLATS (2,587 SF) AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
EXISTING COMMNET LEASE AREA
PROPRIETARY (2,587 SF) FIRSTNET
RD RD
WICKENBURG RANCHOS
IS ROAD PEAK ROAD PEAK AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
ACCESS VULTURE ACCESS VULTURE
SHEET TITLE
CONSTRUCTION
FROM FROM
OF OVERALL SITE PLAN
SET
THIS
IN
CONTAINED
SHEET NUMBER
INFORMATION A-1.1
NORTH NORTH NORTH
0 3' 6' 12' SCALE: 3/32"=1'-0" (22x34) DEMOLITION OVERALL SITE PLAN 0 3' 6' 12' SCALE: 3/32"=1'-0" (22x34)
THE PROPOSED OVERALL SITE PLAN 2 1
(OR) 3/64"=1'-0" (11x17) (OR) 3/64"=1'-0" (11x17)

DISCLAIMER
· THIS SITE PLAN WAS GENERATED WITHOUT
THE BENEFIT OF A CURRENT SURVEY OR
ANY SURVEY. LOCATIONS OF PROPERTY
LINES AND UTILITIES ARE PRELIMINARY.
EXISTING TRANSFORMER
ON CONCRETE PAD Connecting Rural America
TM
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
EXISTING TRANSFORMER
www.sacw.com
(AT&T POWER P.O.C.)
PROPOSED AT&T POWER ROUTE
(±25') IN 3" Ø PVC SCH 40 CONDUIT
PROPOSED AT&T 153 SF PRIMARY GROUND SPACE
PROPOSED AT&T ICE BRIDGE
PROPOSED AT&T DELTA 2-BAY EQUIPMENT 604 FOX GLEN
CABINET, (1) TOTAL BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
PROPOSED 45'-0" MONOPOLE TOWER ON PRIMARY EXISTING COMMNET H-FRAME FAX : 847.277.0080
6'-0" DIA NEW CONCRETE FOOTING PROPOSED 13'-0" W/EQUIPMENT TO REMAIN ae@westchesterservices.com
GROUND
AT&T
JOHN M. BANKS
SPACE EXISTING METAL PLATFORM WITH
PROPOSED AT&T FIBER ROUTE CONCRETE BLOCKS TO REMAIN ARCHITECT
PROPOSED 1" ∅ PVC SCH 40 CONDUIT
PROHIBITED.
STRICTLY
EXISTING COMMNET EQUIPMENT
IS CABINETS TO REMAIN REVISIONS
REV. DATE DESCRIPTION INITIALS
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
B 09/16/20 90% CD FOR REVIEW YH
CARRIER C 10/16/20 90% CD FOR REVIEW YH
5'-10" AT&T SPACE D 12/02/20 90% CD FOR REVIEW YH
TO 11'-9"
E 01/07/21 90% CD FOR REVIEW DWM
GROUND
RELATES PROPOSED COMMNET PROPOSED F 02/09/21 90% CD FOR REVIEW YH
438 SF LEASE AREA
PRIMARY
WHICH
EXISTING 40'-0" MONOPOLE
THAT 3'-7" TOWER TO BE DISASSEMBLED
EXISTING COMMNET 15kW EXISTING ABOVE AND REMOVED
THAN
STANDBY GENERATOR WATER PIPE
OTHER EXISTING COMMNET
GENERATOR
EXISTING COMMNET FIBER CABINET
DISCLOSURE
(AT&T FIBER P.O.C.) (VIF) EXISTING UNDERGROUND
WATER PIPE
OR
USE EXISTING 3' ACCESS GATE
ANY NEW COMMNET ICE BRIDGE
EXISTING
W/NEW COMMNET FIBER, WATER
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. DC CABLES AND COAX TANK BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
EXISTING UNDERGROUND
WATER PIPE
PROPRIETARY EXISTING
FIRSTNET
WATER
WICKENBURG RANCHOS
TANK
IS EXISTING CHAIN-LINK FENCE W/BARBED AZL02819A
WIRE AND PRIVACY SLATS 1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
SHEET TITLE
CONSTRUCTION
EXISTING CHAIN-LINK FENCE W/BARBED
WIRE AND PRIVACY SLATS
OF SITE PLAN
SET
THIS
IN
CONTAINED
SHEET NUMBER
INFORMATION A-1.2
NORTH NORTH NORTH
0 1' 2' 4' SCALE: 1/4"=1'-0" (22x34) 0 1' 2' 4' SCALE: 1/4"=1'-0" (22x34)
THE PROPOSED SITE PLAN 2 DEMOLITION SITE PLAN 1
(OR) 1/8"=1'-0" (11x17) (OR) 1/8"=1'-0" (11x17)

PROPOSED AT&T 8'-0"X7'-6"
CONCRETE EQUIPMENT PAD
Connecting Rural America
1
A-4.2
TM
PROPOSED AT&T DELTA 2-BAY
EQUIPMENT CABINET, (1) TOTAL PROPOSED AT&T SURGE
SUPPRESSOR
1 (DC9-48-60-24-8C-EV), (1) TOTAL ALPHA
PROPOSED AT&T POWER ROUTE (±25') 30°
PROPOSED 3" Ø PVC SCH 40 CONDUIT A-4.0 @ 5015 SHOREHAM PLACE, SUITE 150
4 SAN DIEGO, CA 92122
PROPOSED AT&T 200A ELECTRICAL PANEL A-4.1 PROPOSED SECTOR www.sacw.com
CABINET TO BE LOCKABLE, W/PRE-WIRED
GENERATOR RECEPTACLE BY MANUFACTURER PROPOSED 45'-0" MONOPOLE
TOWER ON NEW 6'-0" DIA
CONCRETE FOOTING
SPACE PROPOSED AT&T ANTENNA & RRU 604 FOX GLEN
PROPOSED AT&T ICE BRIDGE RING MOUNT BY VALMONT P/N: BARRINGTON, IL 60010
GROUND PROPOSED UGLM-DCP, (1) TOTAL TELEPHONE: 847.277.0070
FAX : 847.277.0080
4 11'-9" 2 ae@westchesterservices.com
AT&T
A-4.2 PRIMARY A-4.1
13'-0"
AT&T PAD PRIMARY
8'-0" JOHN M. BANKS
PROPOSED AT&T FIBER ROUTE
PROPOSED 1" Ø PVC SCH 40 CONDUIT PROPOSED CONCRETE 5'-8" GROUND ARCHITECT
SPOACE
PROHIBITED.
STRICTLY
PROPOSED AT&T FIBER BOX REVISIONS
IS
MOUNTED ON NEW ICE 1'-2" REV. DATE DESCRIPTION INITIALS
10"
SERVICES BRIDGE POST
A 07/10/20 90% CD FOR REVIEW LJ
B 09/16/20 90% CD FOR REVIEW YH
CARRIER C 10/16/20 90% CD FOR REVIEW YH
4"
3'-7" D 12/02/20 90% CD FOR REVIEW YH
TO
2'-1" E 01/07/21 90% CD FOR REVIEW DWM
RELATES F 02/09/21 90% CD FOR REVIEW YH
GAMMA
WHICH 240°
3'-6"
PROPOSED @
THAT PROPOSED AT&T H-FRAME SECTOR
THAN SECTOR PROPOSED
3
OTHER A-4.2 @
BETA
150°
DISCLOSURE 7'-6"
CONCRETE
OR PAD PROPOSED AT&T ELECTRICAL PROPOSED AT&T PANEL ANTENNA,
USE METER W/MAIN SERVICE BREAKER (3) TOTAL, (1) PER SECTOR (TYP.
ANY 5'-0" ALL SECTORS)
6 1 "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
A-4.2 A-4.1 AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
PROPOSED AT&T RADIO AHFIB
PROPRIETARY (NOKIA LTE B25/B66), (3) TOTAL, (1)
1'-6" FIRSTNET
PER SECTOR (TYP. ALL SECTORS)
WICKENBURG RANCHOS
IS 1'-3" AZL02819A
3
1551 SOUTH VULTURE MINE RD
A-4.1
DOCUMENTS WICKENBURG, AZ 85390
PROPOSED AT&T SURGE SUPPRESSOR
(DC12-48-60-0-25E-SS), (1) TOTAL
PROPOSED AT&T RADIO AHLBA
SHEET TITLE
2 PROPOSED AT&T 153 SF PRIMARY (NOKIA LTE B12/B14), (3) TOTAL,
CONSTRUCTION GROUND SPACE (1) PER SECTOR (TYP. ALL SECTORS)
A-4.2
PROPOSED ANTENNA &
OF PROPOSED AT&T (3) 6 AWG DC TRUNK CABLES 5
(LENGTH: ±70) AND (1) PROPOSED AT&T FIBER A-4.1 EQUIPMENT PLANS
SET
TRUNK 24 PAIR CABLE (LENGTH: ±70) WITH AT&T
THIS PROPOSED 8 AWG JUMPERS (LENGTH: ±30')
IN
CONTAINED
PROPOSED 45'-0" MONOPOLE TOWER SHEET NUMBER
ON NEW 6'-0" DIA CONCRETE FOOTING
INFORMATION A-2.0
NORTH NORTH
0 3" 6" 1' SCALE: 3/4"=1'-0" (22x34) 0 3" 6" 1' SCALE: 1"=1'-0" (22x34)
THE PROPOSED AT&T EQUIPMENT PLAN 2 PROPOSED AT&T ANTENNA PLAN 1
(OR) 3/8"=1'-0" (11x17) (OR) 1/2"=1'-0" (11x17)

EXISTING RELOCATED COMMNET
FTTA BOX, (1) TOTAL
ALPHA
PROPOSED 45'-0" MONOPOLE TOWER ON 30°
NEW 6'-0" DIA CONCRETE FOOTING @
Connecting Rural America
PROPOSED SECTOR
TM
EXISTING CHAIN-LINK FENCE W/BARBED WIRE
5015 SHOREHAM PLACE, SUITE 150
AND PRIVACY SLATS
SAN DIEGO, CA 92122
www.sacw.com
EXISTING COMMNET H-FRAME
EXISTING COMMNET METER W/DISCONNECT
AND ELECTRIC DISTRIBUTION CABINET
3'-4"
604 FOX GLEN
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
PROPOSED 45'-0" MONOPOLE FAX : 847.277.0080
TOWER ON NEW 6'-0" DIA GAMMA ae@westchesterservices.com
240°
CONCRETE FOOTING @
PROPOSED
SECTOR
SECTOR PROPOSED JOHN M. BANKS
15'-0"
ARCHITECT
@
BETA
10'-3" 150°
PROHIBITED. PROPOSED COMMNET ANTENNA &
RRU RING MOUNT BY VALMONT
P/N: UGLM-DCP, (1) TOTAL
STRICTLY
1
IS A-4.4 REVISIONS
REV. DATE DESCRIPTION INITIALS
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
EXISTING RELOCATED COMMNET
B 09/16/20 90% CD FOR REVIEW YH
ANTENNAS, (3) TOTAL, (1) PER SECTOR
CARRIER (TYP. ALL SECTORS) C 10/16/20 90% CD FOR REVIEW YH
5'-9 D 12/02/20 90% CD FOR REVIEW YH
TO 1/2"
E 01/07/21 90% CD FOR REVIEW DWM
RELATES 1'-6" F 02/09/21 90% CD FOR REVIEW YH
WHICH
THAT EXISTING RELOCATED 4' DIA RFS
SBX1-190 MW, 66 IBS., (2) FLEX
THAN 1/2" MW WAVEGUIDE, AND (2) ODU V1 RADIOS
7'-7
OTHER 322.98°
AZIMUTH
AZ
DISCLOSURE 10'-6" PROPOSED 45'-0" MONOPOLE TOWER ON
NEW CONCRETE FOOTING
OR
USE
ANY PROPOSED CHAIN MOUNT (VALMONT
PROPOSED COMMNET FIBER,
CHM1 OR APPROVED EQUAL)
DC AND COAX CABLES "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
1 AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY EXISTING COMMNET FIBER CABINET A-4.4 THE STATE OF ARIZONA"
(AT&T FIBER P.O.C.) (VIF)
PROPRIETARY
FIRSTNET
1/2"
4'-1 WICKENBURG RANCHOS
IS PROPOSED COMMNET ICE BRIDGE AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
4
A-4.2
SHEET TITLE
CONSTRUCTION EXISTING COMMNET GENERATOR
PROPOSED ANTENNA &
OF
EQUIPMENT PLANS
SET
THIS COMMNET
IN
CONTAINED
SHEET NUMBER
INFORMATION A-2.1
NORTH
NORTH
0 6" 1' 2' SCALE: 1/2"=1'-0" (22x34) 0 3" 6" 1' SCALE: 1"=1'-0" (22x34)
THE PROPOSED COMMNET EQUIPMENT PLAN 2 PROPOSED COMMNET ANTENNA PLAN 1
(OR) 1/4"=1'-0" (11x17) (OR) 1/2"=1'-0" (11x17)

NOTE: LIGHT GREEN AS PER JDX
· ALL PROPOSED ANTENNAS AND
MICROWAVE DISHES SHALL BE PAINTED
TO MATCH THE EXISTING STRUCTURE.
Connecting Rural America
PROPOSED 45'-0" MONOPOLE TOWER ON NEW TOP OF RELOCATED APPUTENANCES TM
6'-0" DIA CONCRETE FOOTING ELEV. 49'-0" AGL
EXISTING RELOCATED COMMNET FTTA BOX, PROPOSED COMMNET ANTENNAS &RRUS
(1) TOTAL. 5015 SHOREHAM PLACE, SUITE 150
RING MOUNT BY VALMONT P/N: UGLM-DCP, SAN DIEGO, CA 92122
(1) TOTAL www.sacw.com
TOP OF NEW STRUCTURE
ELEV. 45'-0" AGL
EXISTING RELOCATED COMMNET RADIOS,
(3) TOTAL, (1) PER SECTOR, (TYP. ALL
SECTORS) C.L. OF EXISTING RELOCATED ANTENNAS
ELEV. 41'-0" AGL OVERALL HEIGHT OF EXISTING STRUCTURE TO BE REMOVED 604 FOX GLEN
ELEV. 40'-0" AGL BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
PROPOSED AT&T SURGE SUPPRESSOR EXISTING RELOCATED COMMNET FAX : 847.277.0080
(DC9-48-60-24-8C-EV), (1) TOTAL ANTENNAS, (3) TOTAL, (1) PER SECTOR ae@westchesterservices.com
(TYP. ALL SECTORS)
PROPOSED AT&T PRIMARY RAD SPACE
PROPOSED AT&T ANTENNAS & RRUS MOUNT BY ELEV. 35'-0" AGL
JOHN M. BANKS
VALMONT P/N: UGLM-DCP, (1) TOTAL EXISTING ANTENNAS TO BE RELOCATED
ELEV. ± 33'-6" AGL ARCHITECT
PROPOSED AT&T PANEL ANTENNA, (3)
PROHIBITED. TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) RAD CENTER OF PROPOSED AT&T PANEL ANTENNAS
ELEV. 30'-0" AGL EXISTING COMMNET ANTENNAS & RADIOS
PROPOSED AT&T RADIO AHFIB (NOKIA LTE B25/B66), TO BE RELOCATED ON NEW MONOPOLE
(3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS) TOWER
STRICTLY
EXISTING 40'-0" MONOPOLE TOWER TO REVISIONS
IS PROPOSED AT&T RADIO AHLBA (NOKIA LTE B12/B14),
PROPOSED AT&T PRIMARY RAD SPACE BE DISASSEMBLED AND REMOVED REV. DATE DESCRIPTION INITIALS
(3) TOTAL, (1) PER SECTOR (TYP. ALL SECTORS)
SERVICES ELEV. 25'-0" AGL A 07/10/20 90% CD FOR REVIEW LJ
EXISTING RELOCATED 4' DIA RFS SBX1-190 MW, EXISTING MW DISH TO BE RELOCATED ON B 09/16/20 90% CD FOR REVIEW YH
CARRIER PROPOSED AT&T 6 AWG DC TRUNK CABLES (±70'), (3) 66 IBS., (2) FLEX WAVEGUIDE, AND (2) ODU V1 NEW MONOPOLE TOWER C 10/16/20 90% CD FOR REVIEW YH
TOTAL & PROPOSED AT&T 24-PAIR FIBER TRUNK CABLE RADIOS ON NEW CHAIN MOUNT P/N: CHM1
(±70') (1) TOTAL W/PROPOSED 8 AWG JUMPERS (±30') D 12/02/20 90% CD FOR REVIEW YH
TO
1 3 E 01/07/21 90% CD FOR REVIEW DWM
RELATES EXISTING WATER TANK A-2.1 A-4.4 EXISTING WATER TANK F 02/09/21 90% CD FOR REVIEW YH
PROPOSED COMMNET FIBER/DC & COAX CABLES
WHICH EXISTING PUMP STATION BUILDING
C.L. OF EXISTING RELOCATED MICROWAVE DISH EXISTING MW DISH TO BE RELOCATED
THAT PROPOSED AT&T ICE BRIDGE 1/2" ELEV. 15'-0" AGL ELEV. ± 16'-0" AGL
4'-1
THAN PROPOSED AT&T DELTA 2-BAY EXISTING COMMNET H-FRAME W/EQUIPMENT EXISTING PUMP STATION BUILDING
EQUIPMENT CABINET, (1) TOTAL
OTHER PROPOSED COMMNET ICE BRIDGE
EXISTING COMMNET EQUIPMENT CABINETS
DISCLOSURE EXISTING COMMNET GENERATOR
OR
USE
ANY
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
PROPRIETARY TOP OF GRADE TOP OF GRADE FIRSTNET
ELEV. 0'-0" AGL ELEV. 0'-0" AGL WICKENBURG RANCHOS
IS AZL02819A
EXISTING WATER 1551 SOUTH VULTURE MINE RD
DOCUMENTS TANK WICKENBURG, AZ 85390
EXISTING WATER TANK
EXISTING CHAIN-LINK FENCE W/BARBED SHEET TITLE
EXISTING CHAIN-LINK FENCE W/BARBED
CONSTRUCTION WIRE AND PRIVACY SLATS (±7'-0") PROPOSED AT&T FIBER BOX MOUNTED ON
WIRE AND PRIVACY SLATS (±7'-0")
NEW ICE BRIDGE POST
EXISTING COMMNET H-FRAME W/EQUIPMENT EXISTING & PROPOSED
PROPOSED AT&T H-FRAME W/ NEW ELECTRICAL TO REMAIN
OF
METER W/MAIN SERVICE BREAKER NORTHWEST
SET
EXISTING METAL PLATFORM WITH CONCRETE
PROPOSED AT&T 153 SF PRIMARY ELEVATIONS
THIS BLOCKS TO REMAIN
GROUND SPACE
IN
EXISTING COMMNET EQUIPMENT CABINETS TO REMAIN
CONTAINED
SHEET NUMBER
EXISTING COMMNET GENERATOR TO REMAIN
INFORMATION A-3.0
0 1' 2' 4' SCALE: 1/4"=1'-0" (22x34) 0 1' 2' 4' SCALE: 1/4"=1'-0" (22x34)
THE PROPOSED NORTHWEST ELEVATION 2 EXISTING NORTHWEST ELEVATION 1
(OR) 1/8"=1'-0" (11x17) (OR) 1/8"=1'-0" (11x17)

Connecting Rural America
TM
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
www.sacw.com
604 FOX GLEN
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
FAX : 847.277.0080
ae@westchesterservices.com
JOHN M. BANKS
ARCHITECT
PROHIBITED.
STRICTLY
IS REVISIONS
REV. DATE DESCRIPTION INITIALS
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
B 09/16/20 90% CD FOR REVIEW YH
CARRIER C 10/16/20 90% CD FOR REVIEW YH
D 12/02/20 90% CD FOR REVIEW YH
TO
E 01/07/21 90% CD FOR REVIEW DWM
RELATES F 02/09/21 90% CD FOR REVIEW YH
WHICH
THAT
THAN
OTHER
DISCLOSURE
OR
USE
ANY
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
PROPRIETARY
FIRSTNET
WICKENBURG RANCHOS
IS AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
SHEET TITLE
CONSTRUCTION
EQUIPMENT DETAILS &
OF
SPECIFICATIONS
SET
THIS
IN
CONTAINED
SHEET NUMBER
INFORMATION A-4.0
THE DELTA 2-BAY EQUIPMENT CABINET (ESOF020-HCV02) NTS 1

MANUFACTURER: NOKIA MANUFACTURER: NOKIA
MODEL: AHFIB MODEL: AHLBA
MECHANICAL MECHANICAL
NET WEIGHT: 66.1 LBS NET WEIGHT: 101.4 LBS
DIMENSION (LxWxD): 22.05"X12.13"X5.87" DIMENSION (LxWxD): 28.7"X15.4"X9.5"
12.13"
Connecting Rural America
TM
15.4"
28.7"
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
22.05" www.sacw.com
5.87" 9.5"
604 FOX GLEN
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
FAX : 847.277.0080
FRONT VIEW BOTTOM VIEW ISOMETRIC VIEW BOTTOM VIEW ae@westchesterservices.com
NOT USED NTS 7 RADIO AHFIB (OR SIMILAR) NTS 5 RADIO AHLBA (OR SIMILAR) NTS 3
JOHN M. BANKS
ARCHITECT
PROHIBITED.
STRICTLY
IS REVISIONS
REV. DATE DESCRIPTION INITIALS
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
B 09/16/20 90% CD FOR REVIEW YH
CARRIER C 10/16/20 90% CD FOR REVIEW YH
D 12/02/20 90% CD FOR REVIEW YH
TO
E 01/07/21 90% CD FOR REVIEW DWM
RELATES F 02/09/21 90% CD FOR REVIEW YH
WHICH
THAT
THAN
OTHER
DISCLOSURE
3/4"=1'-0" (22x34)
OR ANTENNA & RRU RING MOUNT DETAILS (VALMONT PART #: UGLM-DCP) 2
3/8"=1'-0" (11x17)
USE
ANY MANUFACTURER: RAYCAP RAYCAP DC9 OVER MANUFACTURER: KATHREIN
MODEL: DC9-48-60-24-8C-EV VOLTAGE PROTECTOR MODEL: 80010992K
REMOTE RADIO UNIT CEQ/ANT#: CEQ.21427 WITH DOME COVER CONNECTOR: (12) 4.3-10 FEMALE "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. # OF CIRCUITS PROTECTED: 9 CONNECTOR POSITION: BOTTOM BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
SURGE PROTECTIVE DEVICE: TYPE 2 AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY ANTENNA MOUNTING MAX. CONTINUOUS MECHANICAL THE STATE OF ARIZONA"
PIPE OPERATING DC VOLTAGE: 60 VDC WEIGHT: 133.3 LBS (W/O MOUNTING)
ENCLOSURE TYPE: OUTDOOR NEMA 4X DIMENSIONS (HxWxD): 105.2"X20"X6.9"
PROPRIETARY ENCLOSURE DIMS (LxWxH); 18.28:X10.24"X31.4"
WEIGHT (SYSTEM): 16 LBS MOUNTING HARDWARE: 85010096 (INCLUDED W/ ANTENNA) FIRSTNET
WEIGHT (MOUNT): 10.22 LBS WICKENBURG RANCHOS
IS AZL02819A
DOME SECURING BAND 105.2"
1551 SOUTH VULTURE MINE RD
DOCUMENTS RAYCAP SUPPLIED POLE WICKENBURG, AZ 85390
MOUNTING BRACKET
CLIP FOR ATTACHING
DC9 (OVP)
SHEET TITLE
TO BASE ASSEMBLY (TYP)
PIPE CLAMP MOUNTING
CONSTRUCTION BRACKET SUPPLIED
W/RRU POWER CABLE INGRESS
1/2"X3-5/8"X5-1/2"X3" PORTS (TYP.) ANTENNA MOUNTING AT&T EQUIPMENT
OF KIT (85010096)
PIPE CLAMP FOR RRU U-BOLT (HDG.) INCLUDED W/ ANTENNA DETAILS &
SET SUPPLIED W/RRU RAYCAP SUPPLIED
THIS CROSSOVER PLATE BASE ASSEMBLY 6.9" SPECIFICATIONS
VALMONT PART # SCX3-K FRONT VIEW
IN
OR APPROVED EQUAL SIDE VIEW
CABLE TIE BAR
CONTAINED
1/2"X3-5/8"X5-1/2"X3" SHEET NUMBER
CROSSOVER PLATE
U-BOLT (HDG.)
20"
INFORMATION BOTTOM VIEW A-4.1
1/2"=1'-0" (22x34)
THE PIPE CLAMP MOUNTING BRACKET NTS 6 SURGE SUPRESSOR - DC9-48-60-24-8C-EV NTS 4 80010992K ANTENNA (OR SIMILAR) 1
1/4"=1'-0" (11x17)

PROPOSED 1/2"Ø
PER PLAN PROPOSED 3-1/2"Ø OD
GALV "U" BOLT WITH
GALV. PIPE
(6' -0" MAX) CL WASHER & NUT
CL
PROPOSED 1-5/8"x1-5/8"
PROPOSED 3-1/2"Ø UNISTRUT (P1000T)
A A OD GALV. PIPE
1" POSITIVE
CROWN SECTION C-C Connecting Rural America
PROPOSED
3-1/2"Ø OD #3 TIES @
GALV. PIPE 6'-0" B B 18" MIN. PROPOSED 3-1/2"Ø TM
6-0" C C OD GALV. PIPE
4'-0"
SEE DETAIL D PROPOSED 1/2" U-BOLT,
A307 OR BETTER
(4) #4 EQ.
SPACED PROPOSED P2800-50
U-SHAPE FITTING (TYP. OF 5015 SHOREHAM PLACE, SUITE 150
A A 1" POSITIVE CROWN 2 PER U-BOLT) SAN DIEGO, CA 92122
UNISTRUT www.sacw.com
UNISTRUT SPRING NUT
MIN. HEX HEAD
(MIN. OF 4 PLACES)
CAP SCREW &
4'-0" 6" 6" 4'-0" 1'-6" DIA. 1'-6" DIA. 6" PROPOSED 1/2" HEX NUT NUT (TYP)
SECTION SECTION PROPOSED 1"Ø x 1/8" WASHER
A-A B-B PROPOSED
PROPOSED UNISTRUT EQUIPMENT
604 FOX GLEN
PER PLAN BARRINGTON, IL 60010
1'-6" DIA.
1'-6" DIA. TELEPHONE: 847.277.0070
DETAIL D FAX : 847.277.0080
ae@westchesterservices.com
H-FRAME DETAIL NTS 3
2'-0" JOHN M. BANKS
NOTE: MANUFACTURER: RAYCAP
MIN. MODEL: DC12-48-60-0-25E-SS ARCHITECT
· POSTS TO BE SPACED MIN. 4'-0" O.C. 24" UNIVERSAL CANTILEVER CEQ/ANT#: CEQ.32407
AND MAX 10'-0" O.C. WELDMENT # OF CIRCUITS PROTECTED: 12
SURGE PROTECTIVE DEVICE: TYPE 2
PROHIBITED. 24" WIDE GRIP STRUT MAX. CONTINUOUS
EXISTING H-FRAME OPERATING DC VOLTAGE: 60 VDC
ENCLOSURE TYPE: TYPE 4
ENCLOSURE DIMS (LxWxH); 22.0"X20.0"X8.0"
STRICTLY WEIGHT (SYSTEM): 39 LBS
SINGLE STACK, 24" 22.0"
1-5/8" SPRING NUT
IS ANGLE-BRACKET TRAPEZE KIT REVISIONS
SEE ENLARGED BOLT 20.0" REV. DATE DESCRIPTION INITIALS
UNISTRUT DETAIL
SERVICES CABLE ROUTE A 07/10/20 90% CD FOR REVIEW LJ
10'-0" MAX.
METER CABINET B 09/16/20 90% CD FOR REVIEW YH
CARRIER METER 3-1/2" Ø O.D. GALV. PIPE C 10/16/20 90% CD FOR REVIEW YH
1/2"Ø GALV. STEEL UNISTRUT
U-BOLTS WITH LOCK CABINET D 12/02/20 90% CD FOR REVIEW YH
TO
WASHERS E 01/07/21 90% CD FOR REVIEW DWM
RELATES F 02/09/21 90% CD FOR REVIEW YH
ENLARGED UNISTRUT DETAIL 8.0"
FINISHED GRADE
WHICH
THAT
THAN 4'-0"
OTHER
DISCLOSURE 2'-0"
1"=1'-0" (22x34)
OR METER CABINET TO H-FRAME NTS 6 ICE BRIDGE DETAIL 4 DC12-48-60-25E-SS (OR SIMILAR) NTS 2
1/2"=1'-0" (11x17)
USE
A (4) 1/2"Ø HILTI KWIK BOLT TZ
ANY
EQUIPMENT PER PLAN STAINLESS STEEL (TYPE 316)
PER PLAN ANCHOR WITH 3-1/4" "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. 6" THICK CONCRETE SLAB EMBEDMENT IN CONCRETE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY (f 'c = 2500 PSI @ 28 DAYS) ICC ESR-1917 (SPECIAL THE STATE OF ARIZONA"
INSPECTION REQUIRED-
3/4" CHAMFER, TYP. TORQUE TEST 40FT-LBS)
PROPRIETARY
3" COVER EXISTING COMPOUND FIRSTNET
SURFACE WICKENBURG RANCHOS
IS AZL02819A
4" 1551 SOUTH VULTURE MINE RD
PLAN FINISHED GRADE
DOCUMENTS WICKENBURG, AZ 85390
12"
PER 2"
6"
SHEET TITLE
CONSTRUCTION 3" CLR.
AT&T EQUIPMENT
OF
SCARIFY THE UPPER 6" AND DETAILS &
SET
RE-COMPACT TO 90% RELATIVE
THIS COMPACTION PER ASTM D1557 SPECIFICATIONS
IN 12" A #4 REBAR EACH WAY PER PLAN
3"
AT 1'-0" O.C.
CLR. UNDISTURBED SOIL
CONTAINED
SHEET NUMBER
PLAN SECTION A-A
INFORMATION A-4.2
THE NOT USED NTS 5 CONCRETE EQUIPMENT PAD NTS 1

RESTORE SURFACE MATERIAL
TO ORIGINAL CONDITION AFTER
INSTALLATION OF UTILITIES;
GRADE SURFACE TO LEVEL
Connecting Rural America
UNDISTURBED SOIL
BACKFILL EARTH TO 90% RELATIVE TM
COMPACTION PER ASTM D1557
MIN.
UTILITY WARNING TAPE ENTIRE
2'-0" LENGTH OF CONDUIT RUN
BACKFILL (SAND OR NATIVE SOIL W/ SAND
EQUIVALENT GREATER THAN 30) COMPACT TO 5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
1'-0" 90% RELATIVE COMPACTION PER ASTM D1557 www.sacw.com
1" PVC SCH 40 FIBER CONDUIT WHERE
APPLICABLE (OR PVC SIZING AS REQ'D
3" PER CABLE SIZE)
4"
5-1/2" 5-1/2"
604 FOX GLEN
1"
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
FAX : 847.277.0080
ae@westchesterservices.com
FIBER TRENCH NTS 3
JOHN M. BANKS
ARCHITECT
RESTORE SURFACE MATERIAL
PROHIBITED.
TO ORIGINAL CONDITION AFTER
INSTALLATION OF UTILITIES;
GRADE SURFACE TO LEVEL
STRICTLY
IS UNDISTURBED SOIL REVISIONS
REV. DATE DESCRIPTION INITIALS
BACKFILL EARTH TO 90% RELATIVE
SERVICES COMPACTION PER ASTM D1557 A 07/10/20 90% CD FOR REVIEW LJ
MIN.
B 09/16/20 90% CD FOR REVIEW YH
UTILITY WARNING TAPE ENTIRE
CARRIER 3'-0" LENGTH OF CONDUIT RUN C 10/16/20 90% CD FOR REVIEW YH
BACKFILL (SAND OR NATIVE SOIL W/ SAND D 12/02/20 90% CD FOR REVIEW YH
TO
EQUIVALENT GREATER THAN 30) COMPACT TO E 01/07/21 90% CD FOR REVIEW DWM
RELATES 1'-0" 90% RELATIVE COMPACTION PER ASTM D1557 F 02/09/21 90% CD FOR REVIEW YH
3" PVC SCH 40 ELECTRICAL CONDUIT
WHICH WHERE APPLICABLE (OR PVC SIZING AS
3" REQ'D PER POWER PROVIDER DESIGN)
THAT
4"
THAN
4-1/2" 4-1/2"
OTHER 3"
DISCLOSURE
OR POWER TRENCH NTS 2
USE
ANY
RESTORE SURFACE MATERIAL
TO ORIGINAL CONDITION AFTER "I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. INSTALLATION OF UTILITIES; BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY GRADE SURFACE TO LEVEL THE STATE OF ARIZONA"
UNDISTURBED SOIL
PROPRIETARY
FIRSTNET
BACKFILL EARTH TO 90% RELATIVE
WICKENBURG RANCHOS
COMPACTION PER ASTM D1557
IS AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS MIN. WICKENBURG, AZ 85390
3'-0"
SHEET TITLE
UTILITY WARNING TAPE ENTIRE
CONSTRUCTION LENGTH OF CONDUIT RUN
BACKFILL (SAND OR NATIVE SOIL W/ SAND
EQUIVALENT GREATER THAN 30) COMPACT TO AT&T EQUIPMENT
OF 1'-0" 90% RELATIVE COMPACTION PER ASTM D1557 DETAILS &
SET
1" PVC SCH 40 FIBER CONDUIT WHERE
THIS APPLICABLE (OR PVC SIZING AS REQ'D SPECIFICATIONS
IN PER CABLE SIZE)
3"
CONTAINED 4" 3" PVC SCH 40 ELECTRICAL CONDUIT
WHERE APPLICABLE (OR PVC SIZING AS SHEET NUMBER
2" 1'-1" 3" REQ'D PER POWER PROVIDER DESIGN)
3" 1"
INFORMATION A-4.3
THE DUAL UTILITY TRENCH NTS 1

MANUFACTURER: ZTE
MODEL: ZXSDR - R8882 (2*60W)
MECHANICAL
NET WEIGHT: 23 KG - 50.7 LBS
DIMENSION (LxWxD): 18.9"X12.6"X5.1" (480*320*150 mm)
MANUFACTURER: ZTE
MODEL: ZXSDR - R8882 (2*40W) Connecting Rural America
MECHANICAL
NET WEIGHT: 20 KG - 44.09 LBS TM
DIMENSION (LxWxD): 14.96"X12.6"X5.51" (380*320*140 mm)
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
www.sacw.com
604 FOX GLEN
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
FAX : 847.277.0080
ae@westchesterservices.com
JOHN M. BANKS
ARCHITECT
PROHIBITED.
STRICTLY
IS REVISIONS
REV. DATE DESCRIPTION INITIALS
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
B 09/16/20 90% CD FOR REVIEW YH
CARRIER C 10/16/20 90% CD FOR REVIEW YH
D 12/02/20 90% CD FOR REVIEW YH
TO
E 01/07/21 90% CD FOR REVIEW DWM
RELATES F 02/09/21 90% CD FOR REVIEW YH
WHICH
THAT
THAN
OTHER
DISCLOSURE CHAIN MOUNT DETAILS (VALMONT PART #: CHM1) NTS 3 RADIO ZTE ZXSDR R8882 NTS 2
OR
USE
ANY
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
PROPRIETARY
FIRSTNET
WICKENBURG RANCHOS
IS AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
SHEET TITLE
CONSTRUCTION
COMMNET EQUIPMENT
OF
DETAILS & SPECIFICATIONS
SET
THIS
IN
CONTAINED
SHEET NUMBER
INFORMATION A-4.4
3/4"=1'-0" (22x34)
THE ANTENNA & RRU RING MOUNT DETAILS (VALMONT PART #: UGLM-DCP) 1
3/8"=1'-0" (11x17)

Connecting Rural America
TM
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
www.sacw.com
604 FOX GLEN
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
FAX : 847.277.0080
ae@westchesterservices.com
JOHN M. BANKS
ARCHITECT
PROHIBITED.
STRICTLY
IS REVISIONS
REV. DATE DESCRIPTION INITIALS
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
B 09/16/20 90% CD FOR REVIEW YH
CARRIER C 10/16/20 90% CD FOR REVIEW YH
D 12/02/20 90% CD FOR REVIEW YH
TO
E 01/07/21 90% CD FOR REVIEW DWM
RELATES F 02/09/21 90% CD FOR REVIEW YH
WHICH
THAT
THAN
OTHER
COMMNET PLUMBING DIAGRAM NTS 2
DISCLOSURE
OR
USE
ANY
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
PROPRIETARY
FIRSTNET
WICKENBURG RANCHOS
IS AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
SHEET TITLE
CONSTRUCTION
COMMNET EQUIPMENT
OF
DETAILS & SPECIFICATIONS
SET
THIS
IN
CONTAINED
SHEET NUMBER
INFORMATION A-4.5
THE RF DESIGN AND ENGINEERING SHEET NTS 3 COMMNET PLUMBING DIAGRAM NTS 1

Connecting Rural America
TM
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
www.sacw.com
604 FOX GLEN
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
FAX : 847.277.0080
ae@westchesterservices.com
JOHN M. BANKS
ARCHITECT
PROHIBITED.
STRICTLY
EXISTING TRANSFORMER ON CONCRETE PAD
IS NEW AT&T DELTA 2-BAY CABINET (WUC) 18KW REVISIONS
NEW AT&T 200 AMP MAIN SERVICE NETSURE 5100 (MODEL 582137100- INSTALLED & REV. DATE DESCRIPTION INITIALS
SERVICES BREAKER PRE-WIRED BY MANUFACTURER) A 07/10/20 90% CD FOR REVIEW LJ
NEW AT&T ELECTRICAL B 09/16/20 90% CD FOR REVIEW YH
SERVICE METER - (120/240V, NEW AT&T 200 AMP NEMA 3R RATED
CARRIER OUTDOOR ELECTRIC DISTRIBUTION CABINET C 10/16/20 90% CD FOR REVIEW YH
1PH, 3W, 200 AMP, NEMA 3R)
D 12/02/20 90% CD FOR REVIEW YH
TO NEW UTILITY H-FRAME
NEW AT&T GENERATOR RECEPTACLE E 01/07/21 90% CD FOR REVIEW DWM
RELATES NEW 2-1/2"∅ LIQUIDTIGHT FLEXIBLE F 02/09/21 90% CD FOR REVIEW YH
OUTDOOR CONDUIT
WHICH NEW AT&T CONCRETE
EQUIPMENT SLAB
THAT
WATER PROOF CONDUIT FITTING
THAN
TRANSITION FROM PVC NEW 3"Ø TO 2-1/2"Ø REDUCER
OTHER CONDUIT TO RIGID GALVANIZED
STEEL (RGS) CONDUIT FOR
ABOVE GROUND CONDUIT
DISCLOSURE (EXCEPT WHERE NOTED)
OR
USE
ANY
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY NEW 3"Ø PVC SCH 40 POWER CONDUIT NEW 3"∅ PVC SCH 40 POWER CONDUIT-(3) #3/0, (1) THE STATE OF ARIZONA"
(CONDUIT BY GC AND CONDUCTORS BY #6 GROUND, COPPER THHN/THWN-2 FROM NEW
POWER COMPANY) ELECTRICAL METER TO NEW 200A MAIN
PROPRIETARY
ELECTRICAL CABINET-MAX LENGTH 150FT. FIRSTNET
WICKENBURG RANCHOS
IS AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
SHEET TITLE
CONSTRUCTION
AT&T 1-LINE
OF
DIAGRAM
SET
THIS
IN
CONTAINED
SHEET NUMBER
INFORMATION E-1.0
SCALE
THE AT&T 1-LINE DIAGRAM 1
N.T.S.

NEW (2EA) CAD WELDS AT GROUND BAR
Connecting Rural America
NEW EQUIPMENT BUS BAR ON ISOLATORS,
TYP.
TM
6
G-2.0
NEW #2 AWG BTCW EQUIPMENT
GROUND RING
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
NEW CADWELD CONNECTION, TYP. www.sacw.com
NEW #2 STRANDED CABINET TO GROUND
BAR WITH 3/4"Ø NON-METALLIC SEAL TIGHT
NEW MECHANICAL CONNECTION, TYP.
604 FOX GLEN
BARRINGTON, IL 60010
NEW GROUND ROD WITH TEST WELL, TYP. TELEPHONE: 847.277.0070
FAX : 847.277.0080
5 ae@westchesterservices.com
G-2.0
JOHN M. BANKS
NEW MECHANICAL ARCHITECT
CONNECTION, TYP.
PROHIBITED.
NEW #2 AWG THHN INSULATED
GREEN STRANDED COPPER
WIRE, TYP.
STRICTLY
IS REVISIONS
REV. DATE DESCRIPTION INITIALS
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
B 09/16/20 90% CD FOR REVIEW YH
CARRIER C 10/16/20 90% CD FOR REVIEW YH
NEW ANTENNA BUS BAR W/ D 12/02/20 90% CD FOR REVIEW YH
TO
INSULATORS, TYP. E 01/07/21 90% CD FOR REVIEW DWM
RELATES F 02/09/21 90% CD FOR REVIEW YH
9
G-2.0
WHICH
THAT NEW #2 AWG THHN INSULATED
GREEN STRANDED COPPER WIRE
THAN TO BOTTOM MONOPOLE GROUND
BAR, TYP.
OTHER
DISCLOSURE
OR
USE
NEW GROUND ROD
ANY FOR METER
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
PROPRIETARY
FIRSTNET
WICKENBURG RANCHOS
IS AZL02819A
NEW GROUND ROD 1551 SOUTH VULTURE MINE RD
DOCUMENTS (SPACED 10'-0" MIN.), TYP. WICKENBURG, AZ 85390
4
SHEET TITLE
G-2.0
CONSTRUCTION
NEW #2 AWG THHN INSULATED AT&T EQUIPMENT &
OF GREEN STRANDED COPPER WIRE TO
ANTENNA GROUNDING
SET TOP TOWER BUS BAR, TYP.
THIS PLANS
IN NEW #2 TINNED CADWELDED TO
GROUND RING
CONTAINED
SHEET NUMBER
INFORMATION NORTH NORTH G-1.0
0 3" 6" 1' SCALE: 3/4"=1'-0" (22x34) 0 3" 6" 1' SCALE: 1"=1'-0" (22x34)
THE PROPOSED AT&T EQUIPMENT GROUNDING PLAN 2 PROPOSED AT&T ANTENNA GROUNDING PLAN 1
(OR) 3/8"=1'-0" (11x17) (OR) 1/2"=1'-0" (11x17)

Connecting Rural America
TM
NEW CADWELD CONNECTION, TYP.
5015 SHOREHAM PLACE, SUITE 150
SAN DIEGO, CA 92122
www.sacw.com
EXISTING #2 AWG BTCW EQUIPMENT GROUND
RING
604 FOX GLEN
BARRINGTON, IL 60010
TELEPHONE: 847.277.0070
NEW MECHANICAL CONNECTION, FAX : 847.277.0080
ae@westchesterservices.com
TYP.
JOHN M. BANKS
ARCHITECT
NEW #2 AWG THHN INSULATED
GREEN STRANDED COPPER
PROHIBITED.
WIRE, TYP.
STRICTLY
IS NEW ANTENNA BUS BAR W/ REVISIONS
INSULATORS, TYP. REV. DATE DESCRIPTION INITIALS
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
9
B 09/16/20 90% CD FOR REVIEW YH
G-2.0
CARRIER C 10/16/20 90% CD FOR REVIEW YH
D 12/02/20 90% CD FOR REVIEW YH
TO NEW #2 AWG THHN INSULATED GREEN
STRANDED COPPER WIRE TO BOTTOM E 01/07/21 90% CD FOR REVIEW DWM
RELATES MONOPOLE GROUND BAR, TYP. F 02/09/21 90% CD FOR REVIEW YH
WHICH
NEW GROUND ROD (SPACED
10'-0" MIN.), TYP.
THAT
THAN
4
OTHER G-2.0
DISCLOSURE NEW #2 TINNED CADWELDED
TO GROUND RING
OR NEW #2 AWG THHN INSULATED
USE GREEN STRANDED COPPER WIRE
TO TOP TOWER BUS BAR, TYP.
ANY
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY THE STATE OF ARIZONA"
NEW GROUND ROD WITH TEST WELL,
TYP.
PROPRIETARY
FIRSTNET
5 WICKENBURG RANCHOS
IS G-2.0 AZL02819A
1551 SOUTH VULTURE MINE RD
DOCUMENTS WICKENBURG, AZ 85390
SHEET TITLE
CONSTRUCTION
COMMNET EQUIPMENT &
OF
ANTENNA GROUNDING
SET
THIS PLANS
IN
CONTAINED
SHEET NUMBER
INFORMATION NORTH NORTH G-1.1
0 6" 1' 2' SCALE: 1/2"=1'-0" (22x34) 0 3" 6" 1' SCALE: 1"=1'-0" (22x34)
THE PROPOSED COMMNET EQUIPMENT GROUNDING PLAN 2 PROPOSED COMMNET ANTENNA GROUNDING PLAN 1
(OR) 1/4"=1'-0" (11x17) (OR) 1/2"=1'-0" (11x17)

GROUND WIRES FROM SECTOR FRAMES.
ONE (1) PER INTEGRAL GROUND BAR ON
EACH SECTOR FRAME INSULATOR (TYP. OF 2)
#2 AWG INSULATED GREEN
STRANDED COPPER WIRE 3/8" SS ANGLE ADAPTER
ANTENNA GROUND BAR (TYP. OF 2)
(CIGBE) 3/8" GALV. U-BOLT W/ INSULATOR (TYP. OF 2) MONOPOLE CABLE PORT
WASHER & NUT (TYP.) ANTENNA GROUND BAR Connecting Rural America
INSULATOR, #2 SOLID CADWELDED TO (CIGBE)
(TYP. OF 2) GROUND BAR 2EA CADWELD ON GND BAR MONOPOLE
TM
4"
NEW #2 AWG TINNED COPPER PIPE COLUMN NEW #2 AWG TINNED COPPER
WIRE TO GROUND RING. WIRE TO GROUND RING.
ENCASE GROUND WIRE IN ENCASE GROUND WIRE IN
NON-METALIC LIQUID-TIGHT NON-METALIC LIQUID-TIGHT
CONDUIT WITH SILICONE CONDUIT WITH SILICONE
5015 SHOREHAM PLACE, SUITE 150
SEALANT SEALANT SAN DIEGO, CA 92122
GRADE www.sacw.com
12"
2-HOLE, LONG BARREL, COMPRESSION LUGS, #2 INSULATED
GREEN STRANDED COPPER WIRE (THOMAS AND BETTIS
STAINLESS STEEL GRADE
SERIES OR APPROVED EQUAL) W/18-8 STAINLESS STEEL
MOUNTING
BOLTS, NUTS, AND WASHERS (TYPICAL) SUPPLIED AND
BRACKETS BOLTED
INSTALLED BY CONTRACTOR
DIRECTLY TO TOWER
604 FOX GLEN
#2 INSULATED GREEN THHN STRANDED COPPER WIRE
BARRINGTON, IL 60010
CONDUCTOR DOWNLEAD SECURED WITH TWO HOLE GROUND RING GROUND RING
TELEPHONE: 847.277.0070
COMPRESSION LUG TO GROUND BAR AT BASE OF TOWER FAX : 847.277.0080
ae@westchesterservices.com
GROUND BAR DETAIL NTS 9 EQUIPMENT GROUND BAR NTS 6 MONOPOLE GROUND DETAIL NTS NTS 3
JOHN M. BANKS
ARCHITECT
NEW GALV. STEEL COPPER GROUND ROD
WELL COVER HARGER
#10PS (OR EQUAL)
PROHIBITED. MECHANICAL CONNECTION
FINISHED GRADE
CADWELD CONNECTION
STRICTLY
IS 24" NEW LOOP GROUND RING FIELD VERIFY & TIE INTO REVISIONS
MIN. IN WELL 18'' (MIN) FOR EXISTING GROUNDING SYSTEM REV. DATE DESCRIPTION INITIALS
TESTING PURPOSES
SERVICES A 07/10/20 90% CD FOR REVIEW LJ
36" TEST WELL
B 09/16/20 90% CD FOR REVIEW YH
NEW GROUND ACCESS
CARRIER WELL HARGER #360PS C 10/16/20 90% CD FOR REVIEW YH
(OR EQUAL) GROUND BAR
D 12/02/20 90% CD FOR REVIEW YH
TO
E 01/07/21 90% CD FOR REVIEW DWM
RELATES NEW GROUND RING PER PLAN GROUNDING WIRE F 02/09/21 90% CD FOR REVIEW YH
WHICH
NEW CADWELD TYPE "GY" MOLD SCALE
GROUNDING LEGEND 2
THAT N.T.S.
THAN NEW GROUND ROD PER PLAN
1. ALL DETAILS ARE SHOWN IN GENERAL TERMS. ACTUAL INSTALLATION AND CONSTRUCTION MAY VARY DUE TO SITE
SPECIFIC CONDITIONS.
OTHER
2. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC COMPONENTS USING GROUND WIRES
AND CONNECT TO SURFACE MOUNTED BUS BARS, FOLLOW ANTENNA AND BTS MANUFACTURES PRACTICES FOR
DISCLOSURE
GROUNDING REQUIREMENTS. GROUND COAX SHIELDS AT BOTH ENDS AND EXIT FROM TOWER OR POLE USING
MFR'S PRACTICES.
OR NOT USED 8 TEST WELL NTS #
USE 3. ALL GROUND WIRE SHALL BE GREEN INSULATED WIRE ABOVE GROUND.
ANY
4. GROUND TEST MUST PASS LESS THAN 5 OHMS AND SUBMIT IN CLOSEOUT PACKAGE.
"I HEREBY CERTIFY THAT THESE PLANS WERE PREPARED
NATURE. 5. CONTRACTOR TO ABIDE BY ALL AT&T SAFETY STANDARDS DURING SITE CONSTRUCTION. BY ME AND UNDER MY DIRECT SUPERVISION AND THAT I
AM DULY REGISTERED ARCHITECT UNDER THE LAWS OF
BY FINISHED GRADE THE STATE OF ARIZONA"
6. CONTRACTOR SHALL REFER TO AT&T STANDARDS FOR GROUNDING CONNECTIONS & INSTALLATION METHODS.
PROPRIETARY 7. NOTIFY CONSTRUCTION MANAGER IF THERE ARE ANY DIFFICULTIES INSTALLING GROUNDING SYSTEM DUE TO SITE FIRSTNET
SOIL CONDITIONS. WICKENBURG RANCHOS
IS AZL02819A
MIN. 8. GROUNDING ROD NOTES (WHERE APPLICABLE) 1551 SOUTH VULTURE MINE RD
DOCUMENTS 36" WICKENBURG, AZ 85390
NEW GROUND WIRE PER PLAN 9. ELECTRICAL CONTRACTOR SHALL PERFORM AND PROVIDE THE GROUND RESISTANCE TESTING WITH AN APPROVED
EQUIPMENT DEVICE THAT HAS A CURRENT CALIBRATION. TEST RESULTS SHALL NOT EXCEED 5 OHMS.
SHEET TITLE
CONSTRUCTION
NEW #2 AWG SOLID TINNED
COPPER GROUND RING GROUNDING NOTES &
OF
DETAILS
SET
THIS NEW EXOTHERMIC CADWELD
TYPE "GTC-161T" MOLD
IN
NEW 5/8"∅x10'-0" COPPER, OR
COPPER CLAD STEEL GROUND
CONTAINED ROD
SHEET NUMBER
INFORMATION G-2.0
SCALE
THE NOT USED 7 GROUND ROD NTS # GENERAL GROUNDING NOTES 1
N.T.S.

To: Maricopa County
From: SAC Wireless on behalf of Commnet
RE: SUP Application for Commnet Site: Wickenburg Ranchos
‐‐Zoning Narrative Report‐‐
Commnet – Wickenburg Ranchos
Jurisdiction: Maricopa County
Site location: 1551 South Vulture Mine Rd Wickenburg, AZ 85390
PIN # 505‐44‐005X
Case number: Z2020101
Description of Proposed Use
The FirstNet Network
Commnet Four Corners is currently working in partnership with AT&T and the First Responder Network Authority
to provide the nation’s first‐ever high‐speed nationwide wireless broadband network dedicated to federal, state,
and local first responders. The FirstNet network will provide first responders with priority access to wireless
communications services on a single nationwide network, enabling increased coordination among first responder
agencies and decreased response times throughout the county.
Commnet is proposing a drop and swap where they will be building a new 45’ monopole next to the existing 40’
tower and then decommissioning/demolishing the existing tower. The FirstNet Rad center will be located at 30’
and the comment RAD center will be located at 41’. There will also be an addition of (1) two bay ground cabinet
to the new lese area inside the compound.

Purpose of Request / Description of Proposed Use
The FirstNet Network
Commnet Four Corners is currently working in partnership with AT&T and the First Responder Network Authority
to provide the nation’s first‐ever high‐speed nationwide wireless broadband network dedicated to federal, state,
and local first responders. The FirstNet network will benefit the community by providing first responders with
priority access to wireless communications services on a single nationwide network, enabling increased
coordination among first responder agencies and decreased response times throughout the county.
Commnet is requesting a Special Use Permit for the proposed drop and swap where they will be building a new
45’ monopole with an ultimate tower height of 46’ including the appurtenance next to the existing 40’ tower and
then decommissioning/demolishing the existing tower. The FirstNet Rad center will be located at 30’ and the
comment RAD center will be located at 41’. There will also be the addition of (1) two bay ground cabinet to the
new lese area inside the compound. This is an unmanned facility and will not have any employees or hours of
operation. There will be occasional maintenance to the site that usually occurs either quarterly or twice a year.
Maintenance crews will park in the dirt parking lot southeast of the tower/compound.
According to the pre‐application meeting, the reason for the Special Use Permit instead of an Administrative
Conditional Use Permit is due to not meeting the diameter requirements of the development standards.
According to the code, towers and support structures shall have a maximum diameter of 30 inches (2.5 feet). The
proposed tower has a maximum diameter of 34 inches. Comment could engineer the tower to be within
Maricopa County’s diameter requirements; however, due to safety concerns and in order to build the tower more
structurally sound, the diameter will be slightly over as described above.
The proposed microwave dish will be moved from the existing tower to the new tower. The dish has a diameter
of approximately 4 feet which is below the maximum 4.9’ allowed per MCZO Article 1202.3.1.1.i.
We are also requesting a deviation from MCZO Article 1202.3.1.1.l which requires a solid screen wall of 6’
surrounding the leased area. The new site will stay within the existing compound, which already has a chain link
fence with privacy slats that will remain.
We are requesting that the SUP entitlement be approved for 18 years expiring in 2039, which is when the current
Comment ground lease expires.
The leased area of the site is 618 square feet. 180’ is existing and 438’ is proposed. Please see site plan for
location of leased area on the parcel.
Relationship to Surrounding Properties
The proposed site is compatible with the surround land uses and development as there is already and existing
tower located at the site. The zoning of the site is RU‐43. The proposed height of the new tower will be 45’,
which is below the maximum height of 80’ in a rural district. Additionally, we meet the setback requirement of 2
feet from all property lines for each 1 foot in height. The 45’ tower will need a minimum setback of 90’. We are
over 200’ away from the nearest property line. Please see sheet A‐1.0 indicating the setbacks from the nearest
property line is +/‐ 245.1’ and 260.8’.
The circulation system on and off the site will stay the same as this is an unmanned site and no additional traffic
will occur. The proposed tower is within the existing compound and will not require any removal of mature trees
or cacti. Additionally, the cell tower will not have a stealth design because the tower is located in a sparsely
populated area and will not have a significant visual impact as the tower is only 5’ higher than the original tower.
There are no other known wireless facilities on the subject site or surrounding area within 1000 feet per the
Antenna Structure Registration FCC website.
Public Participation Plan
The public participation plan will include sending a letter to property owners with 300 feet of the property and
will post notice at the property. Please see attached notification letter we sent.

Other Information
If you have any further questions or comments concerning this application, please feel free to contact me at 312‐
858‐9024, or via email at: joseph.levie@sacw.com I thank you in advance for your kind courtesies and attention
with respect to this application.

Maricopa County
Planning & Development Department
Date: December 28, 2020
Bob Fedorka, PE
Planning & Development
501 North 44th Street, Suite 200 Memo To: Darren Gerard, AICP, Deputy Director,
Phoenix, Arizona 85008
Phone: (602) 506-7151 Department of Planning & Development
www.maricopa.gov/planning
Email bob.fedorka@maricopa.gov address: Attn: Ray Banker, Planner, Planning & Development Services
From: Bob Fedorka, PE, PND Engineering Supervisor,
Planning & Development Services
cc: Michael Norris, P.E., PND Engineering Manager,
Planning & Development Services
Subject: Z2020101 – Special Use Permit – Wickenburg Ranchos
WCF Modification
Job Site Address: 1551 S. Vulture Mine Road, Wickenburg
APN(s): 505-44-005X
PND Engineering has reviewed the 1st submittal of the subject application routed for review on
December 16, 2020, for the subject application and has no comments or objections. Work will
occur within the confines of an existing WCF compound.
Please contact me if you have any questions or require clarification of these comments.

Maricopa County
Environmental Services Department
Water and Waste Management DATE: December 17, 2020
Division
Subdivision Infrastructure &
Planning Program TO : Ray Banker, Planning & Development Dept.
1001 N. Central Avenue #150
Phoenix, Arizona 85004 Senior Planner
Phone: (602) 506-0376
Fax: (602) 506-5813
TDD 602 506 6704 FROM: Souren Naradikian, P.E.
Senior Civil Engineer
SUBJECT: 12/17. SUP for CommNet Site - Wickenburg Ranchos. Z2020101
The Maricopa County Environmental Services Department (MCESD) has received
documentation for a Request for SUP.
Based on the submitted documentation, CommNet is requesting a Special Use Permit
for the proposed drop and swap where they will be building a new 45’ monopole next
to the existing 40’ tower and then decommissioning/demolishing the existing tower.
APN # 505-44-005X. MCESD has no concerns.
Based on the above, MCESD raised no objections to the Planning & Development
Department in in Accela Automation on December 17, 2020 and can allow the project
to proceed at this time subject to the following stipulations:
Stipulations: None
It should be noted that this document does not approve the referenced project.
Comments are provided only as advisory to Maricopa County Planning and
Development Department to assist staff to prepare a staff report. Other Maricopa
County agencies may have additional requirements. Final review and approval will be
made through Planning and Development Department procedures. Applicant may
need to submit separate applications to the Maricopa County Environmental Services
Department for approval of proposed facilities regulated by the Department. Review
of any such application will be based on regulations in force at the time of application.