Extracted text (via pymupdf_layout)
3765 characters
Reservation #: ___18420_____ Request to Amend kWh Production or System Equipment Information 1.) Original Reservation Application Information: Estimated number of PV Panels__2212_____ PV Module Manufacturer____Suntech_____________ Model #___Pluto 245W ________________ UL Listing____1703____________________________ What is the DC Watt rating per panel? _245W_ (If multiple PV module manufacturers, break out panel count per manufacturer): ______________________________ Estimated number of Inverters___2_______ Inverter Manufacturer__Advanced Energy__________ Model#(s)_Solaron 333kW (1) & PVPowered 100kW (1) UL Listing__1741______________________________ What is the AC Watt rating per inverter? 333kW & 100kW (If multiple Inverter Manufacturers break out inverter count per manufacturer): __1 each________________________ Original Total Project Costs (“TPC”) $2,557,973 Original Ranking Score:_850________ System Size: 541.94 kWdc Estimated Annual kWh per kWdc: _1710________kWh Original Anticipated Annual kWh Production (system size x est. annual kWh production/kWdc): 926,717 Estimated Annual Incentive Payment (annual estimated kWh x $ 0.085 incentive per kWh): $78,771_____________ 2.) Revised System Information or Est kWh Production (based on Interconnection Agreement): Estimated number of PV Panels 1568__ PV Module Manufacturer__Trina Solar____________ Model #_TSM-240PA05___________________ UL Listing_______1703_________________________ What is the DC Watt rating per panel? _240____ (If multiple PV Module Manufacturers break out panel count per manufacturer): __N/A_________________________ Estimated number of Inverters___7____ Inverter Manufacturer___ABB____________________ Model#(s) _TRIO 50-TL-OUTD-US_____________ UL Listing_____1741___________________________ What is the AC Watt rating per inverter? _50kW________ (If multiple Inverter Manufacturers, break out inverter count per manufacturer): _N/A___________________________ New Total Project Costs (“TPC”): $2,856,181.57__ **New Ranking Score:__850_______ New TPC Cap (TPC x 40%) $1,142,472.63__ New Anticipated Annual kWh Production: _926,717__________________________ Difference from original anticipated kWh production: _0___________________ New Estimated Annual Incentive Payment (annual estimated kWh times $ 0.085 incentive per kWh): $__78,771_____ 3.) Customer/Owner Agreement to new kWh? Customer: System Owner: Name (please print): Maricopa County____________ Name (please print): Maricopa County ____________ Title/Business Name: Maricopa County___________ Title/Business Name: Maricopa County____________ Signature*: ________________________________ Signature: ___________________________________ Date: _____________________________________ Date: _______________________________________ *Customer signature signifies customer approval of new annual production and that this addendum will supersede the original Credit Purchase Agreement – Section 6 Contract Quantity. **Submit a new Ranking Score calculation sheet. Ranking score must not be higher than original. If awarded in prior year, please contact your APS Project Manager for assistance in generating a new prior year ranking score. Notes: - Changes in system size may also change the method used to reimburse/credit for excess generation placed back onto the APS grid. - Changes in system size or kWh production cannot increase the per kWh incentive amounts paid for the production of the system. _____________APS Approval__________________________________________________________APS Approval_____________ 4.) Approval of Amended annual kWh production approved by APS? Yes No APS Representative: Name: _________________________________ Title: _________________________________ Date: _________________________________