MARICOPA COUNTY PM-10 CERTIFIED STREET SWEEPER PROJECTS FOR FY 2023 FUNDING.PDF

Maricopa County — Formal (2023-03-29)

View PDF Item 53 Meeting page

Extracted text (via pymupdf_layout) 50257 characters
March 10, 2023
Ms. Joy Rich, Manager
Maricopa County
301 West Jefferson Street, 10th Floor
Phoenix, Arizona 85003
Dear Ms. Rich:
On March 9, 2023, the Maricopa Association of Governments (MAG) received notification
from the Arizona Department of Transportation (ADOT) that the transposition of federal
Congestion Mitigation and Air Quality Improvement (CMAQ) funds for MAG Highway
User Revenue Funds has been completed for the Prioritized List of Proposed PM-10
Certified Street Sweepers for FY 2023. On November 30, 2022, the MAG Regional Council
approved the Prioritized List of Proposed PM-10 Certified Street Sweepers for FY 2023
CMAQ Funding. Three PM-10 certified street sweeper projects requested by Maricopa
County have been approved for FY 2023 funding for an amount not to exceed $321,437
for each sweeper (see Attachment One). Maricopa County may proceed with the purchase
of the proposed street sweeper projects for FY 2023. In the project applications, Maricopa
County agreed to provide a 5.7 percent cash match. We are requesting that the FY 2023
street sweepers be purchased and the reimbursement request be sent to MAG by
March 10, 2024.
For the FY 2023 street sweepers, MAG member agencies may procure their own street
sweepers. Reimbursement requests are to be sent to MAG. After MAG reviews the
reimbursement request, MAG will send the reimbursement documentation to ADOT and
then ADOT will issue the reimbursement check to the local agencies. Additional details
are provided below.
1. Eligibility - Eligible street sweepers are defined as those which have been certified
by the South Coast Air Quality Management District (SCAQMD) as meeting the
SCAQMD Rule 1186 certification standards. The most recent list of Certified Street
Sweepers Under SCAQMD Rule 1186 is dated February 18, 2022 (see
Attachment Two). It is important to note that not all sweepers on the list are eligible
for funding. At this time, the MAG street sweeper program will continue to fund
only conventionally fueled vehicles to reduce PM-10 until more is understood on
which technology is best suited for the region. In April 2022, MAG presented a
Regional Electrification Readiness Strategic Plan to the MAG Regional Council that

Ms. Joy Rich, Manager
March 10, 2023
Page 2
includes coordination across stakeholders to develop strategies and policy
direction to help prepare the region for future electrification.
It is assumed that, at a minimum, the grant funded street sweepers will be used in
accordance with the lane miles and sweeping cycle submitted with the project
applications.
2. Procurement – For the FY 2023 street sweeper projects, MAG member agencies
may procure their PM-10 certified street sweepers. The procurement of the street
sweepers must conform to applicable state procurement regulations for the
purchase of the certified street sweeper. Since the region has not received any
Federal Highway Administration (FHWA) Buy America waivers for FY 2023 street
sweepers, the federal CMAQ funds cannot be used. In March 2023, ADOT
completed the transposition of federal CMAQ funds for MAG Highway User
Revenue Funds for the Prioritized List of Proposed PM-10 Certified Street Sweepers
for FY 2023.
3. Annual Inventory - According to ADOT policy, MAG is responsible for conducting
and submitting an annual inventory of the certified street sweepers owned by the
jurisdictions to ADOT by October 31. For the annual inventory, MAG will contact
the jurisdictions to obtain information on each street sweeper.
4. Reimbursement - MAG is requesting that the sweepers be purchased and
reimbursement request be sent to MAG by March 10, 2024. Additional costs for
equipment beyond the specifications necessary for compliance with Rule 1186-
certification are not eligible for reimbursement. Examples of additional street
sweeper equipment not eligible for reimbursement are provided in
Attachment Three.
Within 30 days after payment for the street sweeper, submit a copy of the vendor
invoice along with all back-up documentation to the attention of Dean Giles at
MAG. MAG will review the reimbursement request, ADOT Payment Report Form,
and send the invoice documentation to ADOT and ADOT will reimburse Maricopa
County for an amount not to exceed $321,437 for each FY 2023 sweeper.
Documentation that includes a description of the street sweeper, the vehicle
identification number, name of title holder, the cost of the vehicle (copy of invoice
with detailed cost information on optional equipment, bill of sale, etc.), and the
location where the sweeper is kept when it is not in use, should be provided. Also,

Ms. Joy Rich, Manager
March 10, 2023
Page 3
please provide the name of the contact person for the sweeper and telephone
number.
5. Disposition – The ADOT Federal Property Management Standards (see
Attachment Four) requires that each jurisdiction obtain ADOT approval prior
to disposal of a grant funded street sweeper. Each jurisdiction is to request
disposal of a street sweeper in writing to MAG. MAG will send the request to ADOT,
and MAG will in turn forward the ADOT response back to the jurisdiction.
For disposal of an older grant funded street sweeper through any means, the
federal awarding agency is entitled to a share of the proceeds. According to the
ADOT Federal Property Management Standards for disposition through a trade-in
or sale, an amount of the proceeds entitled to the federal awarding agency will be
calculated and applied toward the cost of the new street sweeper and an amount
based on the percentage of the jurisdiction’s participation in the original sweeper
may be used to offset the amount of local cash match required.
On November 30, 2022, the MAG Regional Council approved the prioritized list of
proposed PM-10 certified street sweeper projects for FY 2023 CMAQ funding. Also, on
January 26, 2023, the MAG Regional Council approved the FY 2023 Closeout
Programming that includes an additional $1,897,146 in FY 2023 CMAQ funding for street
sweepers on the prioritized list.
If you have any questions or require additional information, please contact Dean Giles at
602-452-5013 or dgiles@azmag.gov.
Sincerely,
Eric J. Anderson
Executive Director
cc: Caitlin Brady, Roadway Program Manager, Maricopa County
Kimberly Richards, Intergovernmental Coordinator, Maricopa County
Danny De Hoog, Legislative Liaison, Maricopa County

Attachment One
Prioritized List of Proposed PM-10 Certified Street Sweeper Projects for FY 2023 CMAQ Funding
Approved by the MAG Regional Council on November 30, 2022
$1,343,220 in CMAQ Funding is Available for Sweeper Projects+++
Supplemental Information
Have local
resources
been
committed
such as staff
or equipment Number of
to support certified
the operation street
Cost- of the sweepers
Daily Effectiveness The requested certified street sweeper will: sweeper? Please indicate in owned
Emission (CMAQ dollar Replace Replace what geographical and
Reduction cost per non- Expand Increase older area(s) the requested operated
Federal Local Total (Kilograms annual metric certified Area Sweeping certified certified street by your
Agency Cost Cost Cost * /day) ton reduced) sweeper Swept Frequency sweeper Yes No sweeper will operate agency. **
Camelback Rd. to Elliot
Phoenix #2 $331,216 $20,021 $351,237 604 $214   Rd. and 107th Ave. to 32
Central Ave.
New River Rd. to
Phoenix #1 $331,216 $20,021 $351,237 366 $353   Thunderbird Rd. and 32
51st Ave. to Scottsdale
Rd.
MCDOT-maintained
Maricopa $321,437 $19,429 $340,866 203 $617   roads within the 8
County #4 PM-10 nonattainment
area.
MCDOT-maintained
Maricopa $321,437 $19,249 $340,866 98 $1,281   roads within the 8
County #3 PM-10 nonattainment
area.
1

Supplemental Information
Have local
resources
been
committed
such as staff
or equipment Number of
to support certified
the operation street
Cost- of the sweepers
Daily Effectiveness The requested certified street sweeper will: sweeper? Please indicate in owned
Emission (CMAQ dollar Replace Replace what geographical and
Reduction cost per non- Expand Increase older area(s) the requested operated
Federal Local Total (Kilograms annual metric certified Area Sweeping certified certified street by your
Agency Cost Cost Cost * /day) ton reduced) sweeper Swept Frequency sweeper Yes No sweeper will operate agency. **
Maricopa-Casa Grande
Hwy. and Russell Rd.
to SR 238 and Warren
Rd. excluding 2.3 miles
Maricopa++ $281,637 $17,024 $298,661 56 $1,978    belonging Indian Community, to Ak-Chin 3
and SR 347 0.25 miles
north of Lake Shore
Dr. to SR 347 and
Steen Rd.
Subtotal $1,586,943
Amount $1,343,220
Available
Balance ($243,723)
Citywide from 48th St.
Tempe $320,697 $19,384 $340,081 35 $3,582   to Continental east Evergreen, Dr. to 6
south of Warner Rd.
Buckeye $349,926 $21,151 $371,077 19 $7,124   Citywide 8
Riggs Rd. to
Goodyear $341,609 $20,649 $362,258 13 $9,972   Camelback Perryville Rd. Rd. to and Dysart 4
Rd.
2

Supplemental Information
Have local
resources
been
committed
such as staff
or equipment Number of
to support certified
the operation street
Cost- of the sweepers
Daily Effectiveness The requested certified street sweeper will: sweeper? Please indicate in owned
Emission (CMAQ dollar Replace Replace what geographical and
Reduction cost per non- Expand Increase older area(s) the requested operated
Federal Local Total (Kilograms annual metric certified Area Sweeping certified certified street by your
Agency Cost Cost Cost * /day) ton reduced) sweeper Swept Frequency sweeper Yes No sweeper will operate agency. **
MCDOT-maintained
Maricopa $321,437 $19,429 $340,866 11 $11,045    roads within the 8
County #2 PM-10 nonattainment
area.
Meridian Rd. to
Apache $319,754 $19,328 $339,082 4 $33,836   Mountain View Rd. 3
Junction and McKellips Rd. to
Guadalupe Ave.
Total $3,240,366
Applications for Apache Junction, Maricopa, Maricopa County #2, Maricopa County #3, Maricopa County #4, Phoenix #1, Phoenix #2, and Tempe indicate sweeping within four miles of a PM-10
monitor.
Applications for Maricopa County #3, Maricopa County #4, and Phoenix #2 indicate sweeping in Salt River Area.
Applications for Apache Junction and Maricopa indicate sweeping in Pinal County.
* Total cost for the CMAQ eligible portion of the project; excludes ineligible equipment.
** The total number of certified street sweepers owned and operated by the agency, regardless of funding source.
++ For the Maricopa sweeper project, initial funding of $37,914 is available in FY 2023 CMAQ. The remaining $243,723 of the $281,637 requested for the project may become available due to
year-end closeout including any additional funding received by the region.
+++ On January 25, 2023, the MAG Regional Council approved the FY 2023 Closeout Programming that includes an additional $1,897,146 in FY 2023 CMAQ funding for the remaining balance
for the Maricopa (City) project ($243,723), and the Apache Junction, Buckeye, Goodyear, Maricopa County #2, and Tempe projects.
3

Attachment Two
South Coast
Air Quality Management District
21865 Copley Drive, Diamond Bar, CA 91765-4182
(909) 396-2000 www.aqmd.gov
CERTIFIED STREET SWEEPERS UNDER
South Coast AQMD RULE 1186
(AS OF FEBRUARY 18, 2022)
South Coast AQMD Rule 1186 requires local governments within the South Coast Air
Quality Management District (see Figure below) to procure certified street sweepers for
new equipment purchases or new street sweeping contracts made after January 1, 2000
(there are no retrofit requirements under Rule 1186).
Various South Coast AQMD regulations also require procurement of certified street
sweepers to implement specific rule requirements. This list of equipment is updated
periodically based on certifications test results and in response to new information.
The South Coast AQMD Governing Board adopted Rule 1186 street sweeper testing
and certification procedures in September of 1999. Enclosed is a list of equipment that
has met the Rule 1186 certification standards. (The equipment may either be new or
upgraded to meet certification specifications). Questions on equipment capabilities and
options should be directed to your local distributor and/or the manufacturer. Questions
regarding the Rule requirements can be directed to Area Sources, at (909) 396-2390, or
areasources@aqmd.gov.
* Additional sweepers may be certified based on future tests. You can call 1 (800) CUT-SMOG or visit
www.aqmd.gov for the most recent list of Rule 1186 certified equipment.

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• THREE (3) 0.03 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
• FOUR (4) 0.03 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND THE
CHALLENGER
CHALLENGER CONVEYOR
MANUFACTURING
• WATER PUMP TO PROVIDE 25 POUNDS PER SQUARE INCH WATER PRESSURE DURING OPERATION; MAXIMUM
OF 45 POUNDS PER SQUARE INCH
• SEVEN (7) 0.0925 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR UNDERNEATH THE CAB
• TWO (2) 0.0925 INCH DIAMETER ORIFICE NOZZLES PER GUTTER BROOM
CURBTENDER* (GUTTER BROOMS CAN BE OPERATED WITHOUT WATER SPRAYS IF FULLY ENCLOSED SHROUD SYSTEM IS
UTILIZED AND MAINTAINED PER THE MANUFACTURERS SPECIFICATIONS)
(*formerly Wayne CENTURION
Sweepers) • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR ABOVE CONVEYOR
• 300 GALLON WATER TANK
• WATER PUMP TO PROVIDE MINIMUM OF SEVEN GALLONS PER MINUTE
• SINGLE FAN VACUUM SYSTEM
• GLAZED, POLYESTER FILTER SYSTEM (MAINTAINED TO ENSURE PROPER INTEGRITY)
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
2

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
CURBTENDER*
(*formerly Wayne GLADIATOR • SIX (6) 0.0925 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER
Sweepers) • FOUR (4) 0.0925 INCH DIAMETER ORIFICE NOZZLES AT THE REAR BROOM
• WATER PUMP TO PROVIDE 60 POUNDS PER SQUARE INCH WATER PRESSURE
CURBTENDER* • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
(*formerly Wayne WARRIOR • SIX (6) 0.0925 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER
Sweepers)
• WATER PUMP TO PROVIDE 60 POUNDS PER SQUARE INCH WATER PRESSURE
• DIAMOND GRID DUST SEPARATION SCREEN
• LOUVERED CENTRIFUGAL DUST SEPARATOR
AIR CUB (LX/DX) • ONE (1) 0.06 INCH DIAMETER ORIFICE NOZZLE CENTRALLY LOCATED ABOVE FAN INLET IN THE HOPPER
ELGIN CROSSWIND FURY
• TWO (2) 0.047 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE SUCTION TUBE
• FOUR (4) 0.051 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
• PUMP TO PROVIDE 40 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
3

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• DIAMOND GRID DUST SEPARATION SCREEN
• S-TRAP CENTRIFUGAL SEPARATOR
CROSSWIND J • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE HOPPER
ELGIN
• THREE (3) 0.059 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE SUCTION TUBE
• THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
• WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE
• DIAMOND GRID DUST SEPARATION SCREEN
• S-TRAP CENTRIFUGAL SEPARATOR
ELGIN REGENX RM • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE HOPPER
• THREE (3) 0.059 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE SUCTION TUBE
• THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
• WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
4

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND
ELGIN PELICAN P & S PELICAN THE CONVEYOR
S E (WET • TWO (2) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH GUTTER BROOM
SUPPRESSION)
• WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE
• GUTTER/MAIN BROOM FULLY ENCLOSED SHROUD SYSTEM
PELICAN P • ONE OR TWO CENTRIFUGAL DUST EVACUATION FAN(S) TO PROVIDE SUBSTANTIALLY SIMILAR AIRFLOW
ELGIN (WATERLESS WITHIN A NORMAL OPERATING RANGE
SUPPRESSION)
• SYNTHETIC MULTI-POCKET FILTER WITH HYDRAULIC SHAKER FOR DUST REMOVAL
PELICAN P
(COMBINATION) • ALL OF THE FEATURES OF THE WET AND WATERLESS SUPPRESSION PELICAN P STREET SWEEPER WITH THE
ELGIN EQUIPMENT OPERATED IN EITHER THE WET OR WATERLESS MODE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
5

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
EAGLE E • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND
EAGLE F THE CONVEYOR
ELGIN EAGLE (CNG) • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH GUTTER BROOM
BROOM BEAR ROAD • WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE
WIZARD
• GUTTER/MAIN BROOM FULLY ENCLOSED SHROUD SYSTEM
ELGIN EAGLE F • CENTRIFUGAL DUST EVACUATION FAN
(WATERLESS)
• SYNTHETIC MULTI-POCKET FILTER WITH HYDRAULIC SHAKER FOR
DUST CONTROL
• ALL OF THE FEATURES OF THE WET AND WATERLESS EAGLE F STREET SWEEPER WITH THE EQUIPMENT
EAGLE F OPERATED IN EITHER THE WET OR WATERLESS MODE
ELGIN (COMBINATION)
• FOUR (4) 0.060 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND
THE CONVEYOR
BROOM BEAR PLUG-IN • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH GUTTER BROOM
ELGIN
HYBRID ELECTRIC • ELECTIC DRIVEN WATER PUMP TO PROVIDE MINIMUM 80 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
6

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• DIAMOND GRID DUST SEPARATION SCREEN
• FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED IN THE HOPPER
ELGIN GEOVAC • TWO (2) 0.059 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE SUCTION TUBE
• TWO (2) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
• FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES LOCATED AT THE EXTENSION BROOM
• WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE
• DIAMOND GRID DUST SEPARATION SCREEN
• FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED IN THE HOPPER
ELGIN WHIRLWIND MV • TWO (2) 0.059 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE SUCTION TUBE
• TWO (2) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
• FOUR (4) 0.60 INCH DIAMETER ORIFICE NOZZLES LOCATED AT THE EXTENSION BROOM
• PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
7

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• ENCLOSED ELEVATOR SYSTEM
M3 • STEEL OR MIXED POLYESTER MAIN PICK UP BROOM
R3 • ONE (1) 0.072 INCH DIAMETER ORIFICE NOZZLE PER EACH GUTTER BROOM
GLOBAL
ENVIRONMENTAL R4 • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES PER EACH SIDE OF THE MAIN PICK UP BROOM
PRODUCTS M4 • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES IN SPRAY BAR LOCATED BEHIND THE MAIN PICK UP
BROOM
M4 HSD
• TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN SPRAY BAR LOCATED UNDERNEATH THE CAB
M4E Zero Emissions
• WATER PUMP TO PROVIDE 40 POUNDS PER SQUARE INCH WATER PRESSURE
• FOUR (4) 0.072 INCH DIAMETER ORIFICE NOZZLES LOCATED IN FRONT SPRAY BAR
• TWO (2) 0.072 INCH DIAMETER ORIFICE NOZZLES PER EACH GUTTER BROOM
JOHNSTON 310
• ONE (1) 0.026 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE FAN SUCTION HOOD
• WATER PUMP TO PROVIDE 50 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
8

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• ENCLOSED ELEVATOR SYSTEM
3000 • STEEL OR MIXED POLYESTER MAIN PICK UP BROOM
MX450 • ONE (1) 0.072 INCH DIAMETER ORIFICE NOZZLE PER EACH GUTTER BROOM
JOHNSTON
4000 • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES PER EACH SIDE OF THE MAIN PICK UP BROOM
4000 SDS • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES IN SPRAY BAR LOCATED BEHIND THE MAIN PICK UP
BROOM
MST 350
• TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN SPRAY BAR LOCATED UNDERNEATH THE CAB
• WATER PUMP TO PROVIDE 40 POUNDS PER SQUARE INCH WATER PRESSURE
VT605 • TWO (2) 0.039 INCH DIAMETER ORIFICE NOZZLES PER GUTTER BROOM
VT610 • THREE (3) 0.042 INCH DIAMETER ORIFICE NOZZLES PER SUCTION BROOM
JOHNSTON VT650 • THREE (3) 0.039 INCH DIAMETER ORIFICE NOZZLES PER SUCTION NOZZLE
V501 • MULTI-POSITION SUCTION NOZZLE TWO ARM FACILITY
V651
• ONE (1) 0.042 INCH DIAMETER ORIFICE NOZZLE FOR THE IMPELLER FAN
V801
• WATER PUMP TO PROVIDE 50 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
9

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• THREE (3) 0.067 INCH DIAMETER ORIFICE NOZZLES FOR GUTTER BROOMS
• TWO (2) 0.07 INCH DIAMETER ORIFICE NOZZLES FOR CENTER CURTAIN
• FOUR (4) 0.055 INCH DIAMETER ORIFICE NOZZLES FOR FRONT BUMPER
• TWO (2) 0.067 INCH DIAMETER ORIFICE NOZZLES FOR FRONT CURB SPRAY
770 CYCLONE/
JOHNSTON RT655 • TWO (2) 0.07 INCH DIAMETER ORIFICE NOZZLES ON LEFT AND RIGHT SIDE OF PICK
UP HEAD
• THREE (3) 0.082 INCH DIAMETER ORIFICE NOZZLES FOR PICK UP HEAD FRONT SIDE
• SEVEN (7) 0.079 INCH DIAMETER ORIFICE NOZZLES FOR PICK UP HEAD REAR SIDE
• THREE (3) 0.079 INCH DIAMETER ORIFICE NOZZLES FOR WINDROW PATH
• TWO (2) 0.045 INCH DIAMETER ORIFICE NOZZLES FOR PICK UP HEAD SUCTION
• ONE (1) 0.079 INCH DIAMETER ORIFICE NOZZLE FOR BLOWER FAN OUTLET
• PUMP TO PROVIDE 50 POUNDS PER SQUARE INCH WATER PRESSURE
• THREE (3) 0.079 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
• FIVE (5) 0.079 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER
NESCON X-BROOM
• FIVE (5) 0.050 INCH DIAMETER ORIFICE NOZZLES IN MAIN BROOM HOUSING
• WATER PUMP TO PROVIDE 50 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
10

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR
RAPTOR II
NITEHAWK REGENERATIVE AIR • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN HOPPER
SWEEPER **
• TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES ON GUTTER BROOMS
• WATER PUMP TO PROVIDE 70 PSI WATER PRESSURE
** EQUIPPED WITH
PM-10 OPTION
PLEASE NOTE THAT THE PM-10 OPTION PACKAGE DUST CONTROL SYSTEM IS DIFFERENT THAN THE
PACKAGE
STANDARD MODEL
• TWELVE (12) POLYESTER DRY FILTER CARTRIDGES (MAINTAINED TO ENSURE PROPER INTEGRITY)
SCHWARZE EV-1
• FILTRATION CLEANED THREE TIMES PER-MINUTE
• FILTRATION SYSTEM ACTIVE AT ALL TIMES
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
11

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• EIGHT (8) POLYESTER DRY FILTER CARTRIDGES (MAINTAINED TO ENSURE PROPER INTEGRITY)
SCHWARZE EV-2 • FILTRATION SYSTEM OPERATED AT ALL TIMES
• EACH FILTER CLEANED THREE TIMES PER MINUTE
• POLYESTER DRY FILTER CARTRIDGES (MAINTAINED TO ENSURE PROPER INTEGRITY)
SCHWARZE DXR • FILTRATION SYSTEM ACTIVE AT ALL TIMES
• FILTRATION CLEANED FOUR TIMES PER MINUTE AND A HALF
• FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES LOCATED ON THE SWEEPING HEAD
• TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES INSIDE HOPPER
A4000/
SCHWARZE A4STORM • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM
• FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES INSIDE HOPPER ON SPRAY BAR
• WATER PUMP TO PROVIDE 70 POUNDS PER SQUARE INCH WATER PRESSURE
• FIVE (5) 0.036 INCH DIAMETER ORIFICE NOZZLES ON MAIN BROOM
M5000/M6000/
SCHWARZE M6 AVALANCHE • THREE (3) 0.036 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM
• WATER PUMP TO PROVIDE 70 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
12

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• SAWTOOTH DUST SEPARATION SCREEN, SELF DUMPING DUST SEPARATOR, FAN CENTRIFUGE
A 7000/ • FIVE (5) 0.036 INCH DIAMETER ORIFICE NOZZLES LOCATED ON THE SWEEPING HEAD
A7 TORNADO • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES LOCATED ON HEAD INTAKE TUBE
A7 ZEPHYR • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN RIGHT HAND GUTTER BROOM
SCHWARZE A 8000/ • FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES LOCATED ON HOPPER SPRAY BAR
A8 TWISTER • WATER PUMP TO PROVIDE 70 POUNDS PER SQUARE INCH WATER PRESSURE
A 9000/ • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN LEFT HAND GUTTER BROOM (REQUIRED IF BOTH
A9 MONSOON GUTTER BROOMS ARE USED)
S348-I/ • FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES ON HOPPER SPRAY BAR
SUPERVAC • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN HOPPER
VORTEX • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES ON RIGHT HAND GUTTER BROOM
SCHWARZE
S348-LE/ • WATER PUMP TO PROVIDE 70 POUNDS PER SQUARE INCH WATER PRESSURE
SUPERVAC GALE
FORCE
SUPERVAC SUPER
UPDRAFT
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
13

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• FOUR (4) 0.05 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND
THE ELEVATOR
• FOUR (4) 0.05 INCH DIAMETER ORIFICE NOZZLES LOCATED BENEATH THE FRONT BUMPER OF THE CHASSIS
STARFIRE S-4, S-5,
STEWART-AMOS • TWO (2) 0.05 INCH DIAMETER ORIFICE NOZZLES LOCATED IN FRONT OF EACH GUTTER BROOM
AND S-6
• WATER PUMP TO PROVIDE 40 POUNDS PER SQUARE INCH WATER PRESSURE
• FOUR (4) 0.008 INCH DIAMETER ORIFICE NOZZLES MOUNTED ABOVE AND AHEAD OF A 36 INCH FILL
DIAMETER REAR BROOM
PYTHON S2000 • WATER LINE WITH 0.02 INCH DIAMETER ORIFICE AND THREE (3) 0.06 DIAMETER OUTLETS ABOVE
EACH 42 INCH DIAMETER GUTTER BROOM
• PUMP TO PROVIDE 24 POUNDS PER SQUARE INCH WATER PRESSURE DURING OPERATION
PLEASE NOTE THAT THE GUTTER AND REAR BROOM SIZES ARE DIFFERENT THAN THE STANDARD MODEL
• FOUR (4) 0.008 INCH DIAMETER ORIFICE NOZZLES MOUNTED ABOVE AND AHEAD OF REAR BROOM
• WATER LINE WITH 0.02 INCH DIAMETER ORIFICE AND THREE (3) 0.06 DIAMETER OUTLETS ABOVE EACH
PYTHON S3000 GUTTER BROOM
• PUMP TO PROVIDE 24 POUNDS PER SQUARE INCH WATER PRESSURE DURING OPERATION
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
14

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• GUTTER/MAIN BROOM FULLY ENCLOSED SHROUD SYSTEM
TENNANT SENTINEL • DUAL FAN VACUUM SYSTEM (OPERATED AT ALL TIMES)
• SYNTHETIC-SINGED POLYESTER FILTER (MAINTAINED TO ENSURE PROPER INTEGRITY)
• GUTTER/MAIN BROOM FULLY ENCLOSED SHROUD SYSTEM
TENNANT 830 / 831 II • DUAL FAN VACUUM SYSTEM (OPERATED AT ALL TIMES)
• SYNTHETIC-SINGED POLYESTER FILTER (MAINTAINED TO ENSURE PROPER INTEGRITY)
• CYCLONIC, MULTIPASS, CENTRIFUGAL SEPARATION
• CENTER DEBRIS DEFLECTOR ASSEMBLY PERPENDICULAR TO THE PICK UP HEAD
210 • TWO (2) 0.043 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM
TYMCO 300 • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLE FOR EACH GUTTER BROOM
350 • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE HOPPER
435 • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLE LOCATED IN BLOWER HOUSING
• WATER PUMP WITH A MINIMUM SYSTEM RELIEF VALVE SET AT 25 POUNDS PER SQUARE INCH
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
15

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• CYCLONIC, MULTIPASS, CENTRIFUGAL SEPARATION
• CENTER DEBRIS DEFLECTOR ASSEMBLY PERPENDICULAR TO THE PICK UP HEAD
• FRONT DEBRIS DEFLECTOR CURTAIN ASSEMBLY PARALLEL TO THE PICK UP HEAD
600
600 BAH • LOW EMISSION DUST GUARDS (ONLY APPLICABLE TO CABOVER TRUCKS)
TYMCO FHD • THREE (3) 0.063 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM
500X • TWO (2) 0.043 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM
• ONE (1) 0.093 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE HOPPER
• ONE (1) 0.093 INCH DIAMETER ORIFICE NOZZLE LOCATED IN BLOWER HOUSING
• TWO (2) [MINIMUM] HOPPER BAFFLE CURTAINS
• WATER PUMP WITH A MINIMUM SYSTEM RELIEF VALVE SET AT 25 POUNDS PER SQUARE INCH
• CYCLONIC, MULTIPASS, CENTRIFUGAL SEPARATION
• SELF CONTAINED MULTIPLE FILTRATION SYSTEM UTILIZING PTFE MEMBRANE FILTERS
• TWO (2) 0.043 INCH DIAMETER ORIFICE NOZZLES FOR EACH 32 INCH DIAMETER GUTTER BROOM
TYMCO DST - 4 • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLES FOR EACH 32 INCH DIAMETER GUTTER BROOM
• ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE HOPPER
• WATER PUMP WITH A MINIMUM SYSTEM RELIEF VALVE SET AT 25 POUNDS PER SQUARE INCH
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
16

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• CYCLONIC, MULTIPASS, CENTRIFUGAL SEPARATION
• SELF CONTAINED MULTIPLE FILTRATION SYSTEM UTILIZING PTFE MEMBRANE FILTERS
• THREE (3) 0.063 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM
• TWO (2) 0.043 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM
TYMCO DST - 6
• ONE (1) 0.094 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE HOPPER
• TWO (2) [MINIMUM] HOPPER BAFFLE CURTAINS
• WATER PUMP WITH A MINIMUM SYSTEM RELIEF VALVE SET AT 25 POUNDS PER SQUARE INCH
• FOUR (4) 0.062 INCH DIAMETER ORIFICE NOZZLES LOCATED IN FRONT OF EACH 36 INCH GUTTER BROOM
VS10/10D, VF10 • FOUR (4) 0.062 INCH DIAMETER ORIFICE NOZZLES LOCATED IN FRONT OF THE TRANSFER BROOM
VS13/13D, VF13 • TEN (10) 0.125 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE PICK UP HEAD
VACALL VS14/14D, VF14 • SIX (6) 0.181 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE SCRUBBER COLLAR OF THE PICK UP
VS16/16D, VF16 HEAD
VS20/20D, VF20 • 48 INCH POWER VACUUM NOZZLE
• MINIMUM 300 GALLON GRAVITY FEED WATER SUPPLY SYSTEM WITH WATER CONTINUOUSLY SUPPLIED TO
ALL NOZZLES
• LOW VELOCITY DUST COLLECTION AIR CHAMBER
• MINIMUM OF SIX (6) EXPANDED METAL SCREENS
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
17

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
MAKE* MODEL* DUST CONTROL SYSTEM*
• SEVEN (7) 0.0925 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR UNDERNEATH THE CAB
• TWO (2) 0.0925 INCH DIAMETER ORIFICE NOZZLES PER GUTTER BROOM
• (GUTTER BROOMS CAN BE OPERATED WITHOUT WATER SPRAYS IF FULLY ENCLOSED SHROUD SYSTEM IS
WAYNE SWEEPERS* UTILIZED AND MAINTAINED PER THE MANUFACTURERS SPECIFICATIONS)
CENTURION
(*acquired by • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR ABOVE CONVEYOR
Curbtender)
• 300 GALLON WATER TANK
• WATER PUMP TO PROVIDE MINIMUM OF SEVEN GALLONS PER MINUTE
• SINGLE FAN VACUUM SYSTEM
• THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
WAYNE SWEEPERS GLADIATOR • SIX (6) 0.0925 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER
(*acquired by Curbtender)
• FOUR (4) 0.0925 INCH DIAMETER ORIFICE NOZZLES AT THE REAR BROOM
• WATER PUMP TO PROVIDE 60 POUNDS PER SQUARE INCH WATER PRESSURE
• THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM
WAYNE SWEEPERS
(*acquired by Curbtender) WARRIOR • SIX (6) 0.0925 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER
• WATER PUMP TO PROVIDE 60 POUNDS PER SQUARE INCH WATER PRESSURE
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
18

SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD)
RULE 1186 CERTIFIED* STREET SWEEPERS AS OF FEBRUARY 18, 2022
THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE
1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S
SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST
ADDITIONAL NOTES:
** For any entity wishing to operate a NiteHawk Raptor II compliant with Rule 1186, the sweeper must be ordered with PM-10 Option Package, which includes
the following:
- Front Spray bar configured with Four (4) 0.036-inch Orifice Spray Nozzles
- Two (2) Sweeper Head Spray Nozzles Removed from the Dust Suppression System
- 24” Whisper Wheel Fan Turbine Installed in place of Standard Hi Flow Fan Turbine
- Low Profile Brooms installed (applicable to driver side and passenger side brooms)
o 60 holes, 17 bristles. Bristle Dimension: 20” Length, 0.034” Thick, 0.011” Width
- Blower Vacuum System
o System will be tuned to an airflow rating of 6,178 CFM
o System will be tuned to deliver 27 HP at fan
* In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the
manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper.
Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have
all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant.
19

Attachment Three
May 19, 2017
EXAMPLES OF ADDITIONAL STREET SWEEPER EQUIPMENT
NOT ELIGIBLE FOR REIMBURSEMENT
1. Automatic lubrication system 19. Foam filled tire
(Autolube, grease jockey system)
20. Window tinting
2. Hopper access step
21. Move exhaust port to left side of vehicle
3. Hydrant hopper wash down system
22. John Deere auxiliary engine - Tier iT4
4. Conveyer flush kit with hydrant
5. 1000 pounds per square inch (PSI) wand
6. Dual HiBack air-suspended seats
7. Hand hose
8. Hopper sound suppression
9. Right hand steer chassis upcharge
10. Air horn (reimbursable when
conventional electric horn is not
included)
11. AM/FM radio; CD
12. Training
13. Magnet bar
14. Stainless steel hopper
15. Sweeper, truck and wheel yellow paint
16. Additional roof-mounted air
conditioner
17. Holder rear mount for five-gallon pail
18. Cigarette lighter with 12v

Attachment Four
Infrastructure Delivery and Operations
MEMORANDUM
TO: PM 10 Street Sweepers Program Awardees
FROM: Lisa Pounds, Local Public Agency Manager
CC: Patrick Stone, Federal Aid Administrator
DATE: Tuesday June 11, 2019
RE: Interim Process for Disposition of Street Sweepers acquired with federal funds under FIN-
11.08 Federal Property Management Standards Policy
This memorandum serves as notice to recipients and subrecipients of federal funds through a
pass-through entity that acquire, in whole or in part, with federal funds or whose costs are
charged to a project supported by a federal grant, of a change in procedure for the disposition
of street sweepers owned by subrecipients. Due to administrative changes in the PM 10 Street
Sweeper Program, ADOT Policy FIN-11.08 Federal Property Management Standards (attached)
is in the process of being updated. In the interim, ADOT is requesting that subrecipients no
longer forward funds resulting from the trade-in or sale without replacement of sweepers to
the entity from which it received funds for the original purchase. Instead, the funds will need
to be forwarded to ADOT. ADOT’s Financial Management Services division will make
adjustments to the current or future year distribution from the federal awarding agency.
Should you have any questions regarding this change in procedure, you may contact me at
LPounds@azdot.gov or 602-712-8088.
Sincerely,
Lisa Pounds
Local Public Agency Manager
ARIZONA DEPARTMENT OF TRANSPORTATION
1801 W. Jefferson St., Suite 120, MD 102M | Phoenix, AZ 85007 | azdot.gov