Irvins Guest House Packet
City of Tolleson — Planning and Zoning Commission (2026-10-27)
Extracted text (via pymupdf_layout)
10286 characters
UNIQUE CAD & DESIGN 911PERMIT@GMAIL.COM 2482 1 UNIQUE CAD & DESIGN FLOOR PLAN KEYNOTES 911PERMIT@GMAIL.COM 2482 2 8725 W C P Hayes DR - Tolleson AZ. Guess House AC Load Calculations for Haro Arredondo Irvin E Prepared By: AC. Design 351 N Meridian Dr Apache Juntion Arizona 85120 Tuesday, May 5 , 2026 Rhvac - Residential HVAC Loads - A.J.az. Page 2 Project Report General Project Information Project Title: 8725 W C P Hayes DR Designed By: AC Desgns . Project Date: 05.05.2026 Client Name: Haro Arredondo Irvin Client Address: 8725 W C P Hayes DR Client City: Company Name: AC. Design Company Address: 351 N Meridian Dr Company City: Apache Juntion Company E-Mail Address: Arizona 85120 Design Data Reference City: Tolleson , Arizona Building Orientation: Front Door , faces North Daily Temperature Range: Hight Latitude: 33 Degrees Elevation: 1106 ft. Altitude Factor: 0.961 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 41 38.4 n/a n/a 70 n/a Summer: 108 70 14% 45% 75 -7 Check Figures Total Building Supply CFM: 579 CFM Per Square ft.: 2.019 Square ft. of Room Area: 287 Square ft. Per Ton: 283 Volume (ft³): 2,292 Building Loads Total Heating Required Including Ventilation Air: 5,850 Btuh 5.850 MBH Total Sensible Gain: 12,227 Btuh 100 % Total Latent Gain: -58 Btuh 0 % Total Cooling Required Including Ventilation Air: 12,227 Btuh 1.02 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2.50, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\ ..2482- irvin's guess house - Tuesday, May 5 , 2026 Rhvac - Residential HVAC Loads - A.J.az. Page 3 Miscellaneous Report System 1 System 1 Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 41 38.4 80% n/a 70 n/a Summer: 108 70 14% 45% 75 -6.89 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 0 ft./min 0 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.610 AC/hr 0.320 AC/hr 23 CFM 12 CFM Infiltration Actual: 0.610 AC/hr 0.320 AC/hr Above Grade Volume: X 2,292 Cu.ft. X 2,292 Cu.ft. 1,398 Cu.ft./hr 733 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 23 CFM 12 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration & Ventilation Sensible Gain Multiplier: 34.87 = (1.10 X 0.961 X 33.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: -4.50 = (0.68 X 0.961 X -6.89 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 30.65 = (1.10 X 0.961 X 29.00 Winter Temp. Difference) Winter Infiltration Specified: 0.610 AC/hr (23 CFM), Construction: Average Summer Infiltration Specified: 0.320 AC/hr (12 CFM), Construction: Average Duct Load Factor Scenarios for System 1 Attic Duct Duct Surface From No. Type Description Location Ceiling Leakage Insulation Area [T]MDD 1 Supply Attic 16B 0.12 8 21.7 MDD C:\ ..2482- irvin's guess house - Tuesday, May 5 , 2026 Rhvac - Residential HVAC Loads - A.J.az. Page 4 Load Preview Report Sys Sys Sys Net ft.² Sen Lat Net Sen Duct Htg Clg Act Scope Ton /Ton Area Gain Gain Gain Loss Size CFM CFM CFM Building 1.02 283 287 12,227 -58 12,227 5,850 79 579 579 System 1 1.02 283 287 12,227 -58 12,227 5,850 79 579 579 12 Supply Duct Latent -3 0 Not MDD: Zone 1 287 12,227 -55 12,227 5,850 79 579 579 9x13 1-Room ( kitchen , bath and bedroom) 287 12,227 -55 12,227 5,850 79 579 579 13 C:\ ..2482- irvin's guess house - Tuesday, May 5 , 2026 Rhvac - Residential HVAC Loads - A.J.az. Page 5 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Room 1 287 5,850 79 13 - 12,227 -55 579 579 Duct Latent -3 System 1 total 287 5,850 79 12,227 -58 579 579 System 1 Main Trunk Size: 12 in. Velocity: 737 ft./min Loss per 100 ft.: 0.068 in.wg Duct size results above are from Manual D Ductsize. Runout duct velocities are not printed with duct size results from Manual D Ductsize since they can vary within the room. See the Manual D Ductsize report for duct velocities and other data. Cooling System Summary Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 1.02 100% / 0% 12,227 -58 12,227 Actual: 1.50 75% / 25% 13,500 4,500 18,000 Equipment Data Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: KUSAE181A KUSAE181A Indoor Model: KNSAE181A Brand: LG LG Description: AHRI 214931167 AHRI 214931167 Efficiency: 8.9 HSPF2 18 SEER2 Sound: 0 0 Capacity: 19,000 Btuh 18,000 Btuh Sensible Capacity: n/a 13,500 Btuh Latent Capacity: n/a 4,500 Btuh AHRI Reference No.: n/a 9152487 This system's equipment was selected in accordance with ACCA Manual S. Manual S equipment sizing data: SODB: 108F, SOWB: 70F, WODB: 41F, SIDB: 75F, SIRH: 45%, WIDB: 70F, Sen. gain: 12,227 Btuh, Lat. gain: -58 Btuh, Sen. loss: 5,850 Btuh, Entering clg. coil DB: 75F, Entering clg. coil WB: 60.9F, Entering htg. coil DB: 70F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. clg. airflow: 579 CFM, Req. htg. airflow: 79 CFM C:\ ..2482- irvin's guess house - Tuesday, May 5 , 2026 Form Residential Plans Examiner Review Form RPER 1.01 for HVAC System Design (Loads, Equipment, Ducts) 8 Mar 10 County, Town, Municipality, Jurisdiction Header Information REQUIRED ATTACHMENTS¹ ATTACHED Contractor Manual J1 Form (and supporting worksheets): Yes No Mechanical License # or MJ1AE Form² (and supporting worksheets): Yes No OEM performance data (heating, cooling, blower): Yes No Building Plan # Manual D Friction Rate Worksheet: Yes No Duct distribution system sketch: Yes No Home Address (Street or Lot#, Block, Subdivision) HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature 41 °F Orientation (Front door faces) North North, East, West, South, Northeast, Northwest, Southeast, Southwest Indoor temperature 70 °F Number of bedrooms 0 Total heat loss 5850 Btu/h 400 Conditioned floor area Sq Ft Summer Design Conditions Outdoor temperature 108 °F Number of occupants 0 Indoor temperature 75 °F Windows Grains difference -7 Gr @ 45 % Rh Eave overhang depth 1.3 Ft Sensible heat gain 12227 Btu/h Internal shade Latent heat gain -58 Btu/h Blinds, drapes, etc Total heat gain 12169 Btu/h Number of skylights 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment type Air Source Heat Pump Equipment type Air Source Heat Pump Furnace, Heat pump, Boiler, etc. Air Conditioner, Heat pump, etc Heating CFM 579 CFM Model KUSAE181A Model KUSAE181A Cooling CFM 579 CFM Heating output capacity 19000 Btu/h Sensible cooling capacity 13500 Btu/h Heat pumps - capacity at winter design outdoor conditions Latent cooling capacity 4500 Btu/h Auxiliary heat output capacity Btu/h Total cooling capacity 18000 Btu/h HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow 579 CFM Longest supply duct: Ft Duct Materials Used (circle) 99 Trunk Duct: Duct board, Flex, Sheet metal, External Static Pressure (ESP) 0.43 IWC Longest return duct: Ft Lined sheet metal, Other (specify) Component Pressure Losses (CPL) 0.35 IWC Total Effective Length (TEL) 99 Ft Branch Duct: Duct board, Flex, Sheet metal, Available Static Pressure (ASP) 0.078 IWC Friction Rate: 0.08 IWC Lined sheet metal, Other (specify) ASP = ESP - CPL Friction Rate = (ASP × 100) ÷ TEL I declare the load calculation, equipment selection, and duct system design were rigorously performed based on the building plan listed above, I understand the claims made on these forms will be subject to review and verification. Contractor's Printed Name Date Contractor's Signature Reserved for use by County, Town, Municipality, or Authority having jurisdiction. ¹ The AHJ shall have the discretion to accept Required Attachments printed from approved ACCA software vendors, see list on page 2 of instructions. ² If abridged version of Manual J is used for load calculation, then verify residence meets requirements, see Abridged Edition Checklist on page 13 of instructions. Form generated by ACCA-approved Manual J Eighth Edition Version 2 Elite Software Rhvac program. 9055 W. Van Buren St., Tolleson, AZ 85353 • (623) 936-7111 • TTY users, dial 711 for Relay • www.tolleson.az.gov AFFIDAVIT OF POSTING On October 5, 2026, Ken Hernandez certify that the following public notice was posted on the property per A.R.S. § 9-462.04: NOTICE OF PUBLIC HEARINGS CITY OF TOLLESON NOTICE IS HEREBY GIVEN that the City of Tolleson Planning and Zoning Commission will conduct a PUBLIC HEARING on TUESDAY, OCTOBER 27, 2026 at 5:00 PM, and the Mayor and Council will conduct a PUBLIC HEARING on TUESDAY, OCTOBER 27, 2026 at 6:00 PM, both during Regular Meetings held in the Council Chambers at the Tolleson Civic Center, 9055 West Van Buren Street, Tolleson, Arizona 85353, and via Zoom Webinar. Planning and Zoning Commission Webinar: https://us02web.zoom.us/j/83763983293 (Meeting ID: 837 6398 3293); Mayor and Council Webinar: https://us02web.zoom.us/w/84069679194 (Meeting ID: 840 6967 9194); and telephone access for both meetings: 1-253-215-8782. The purpose of the public hearings is to solicit comments from interested parties regarding Use Permit Application No. PNZ-26-0027, submitted by the property owner Haro Arredondo Irvin E., to construct a separate 400-square-foot guest house at 8725 W. C.P. Hayes Drive, Tolleson, Arizona 85353. The subject property, identified as APN 102-48-249, is approximately 7,179 square feet and is currently zoned Residential Single-Family (R1-7). Published in the Arizona Business Gazette–Republic Edition on October 9, 2026. KHERNANDEZ Ken Hernandez, Code Compliance Officer