Sign Plan

City of Mesa — Board of Adjustment Public Hearing (2026-11-04)

View PDF Meeting page

Extracted text (via pymupdf_layout) 14786 characters
g should be employed to BULLSEYE
e staging area. AND
ontainers "TARGET"
rs are 40' long) SIGN
3-4 Dumpsters
ical lift machines (Approx. 15)
TARGET STORE
TARGET STORE
EXISTING TARGET
MONUMENT SIGN
CVS
PHARMACY
SIGN ORDER
PICKUP
SIGN
DRIVE UP
SIGN BULLSEYE
AND
"TARGET"
SIGN
Staging Area
EXISTING TARGET
MONUMENT SIGN
Image Source: Nearmap US, Inc.
NTS
T0639 Mesa East
1525 S Power Rd REM STAGING PLAN
Mesa, AZ 85206 04/07/2026

COLOR KEY:
DE# 346 SWAN WHITE
DE# 6192 NOMADIC TAUPE
DE# 692 KILN DRIED
C-20 CHAMPAGNE
C-1 RED
All paint colors shown are new paint colors. This scope
intends to get the new paint colors approved.
Front Elevation
Left Elevation
NOTE:
Rear Elevation
*EXISTING FINISHES SHOWN FOR REFERENCE.
* EXISTING ICCMU AND PREFINISHED METAL AREAS-NO
PAINT; PAINT HM DOOR AND FRAME TO MATCH ADJ.
WALL, TYP.
*STORE EXTERIOR WALLS ARE PRIMARILY CMU
*BEN-5 : STRAIGHT, COLOR..................RED
GENERAL NOTE
* AREA TO BE PAINTED STARTS AT TOP OF CURB OR REVEAL AND
CONTINUES TO TOP OF PARAPET/FLASHING OR REVEAL. PAINT COLOR
AND FINISH TRANSITIONS OCCUR AT EXISTING VERTICAL CONTROL
JOINTS OR AT INSIDE BUILDING CORNERS, U.N.O.
* ALL EXISTING WALL-MOUNTED ITEMS TO BE PAINTED TO MATCH ADJ.
WALL SURFACE, U.N.O.
Right Elevation * PATCH ALL VISIBLE HOLES FROM MOUNTING OF REMOVED SIGNS WITH
LIKE MATERIALS. RESTORE WALL SURFACE TO ‘ LIKE NEW’ APPEARANCE.
168 SF
RSP Architects Ltd.
T-Meza East, AZ: Remodel - Exterior Design March 09, 2026

Existing Condition
Front Elevation
RSP Architects Ltd.
T-Meza East, AZ: Remodel - Exterior Design March 09, 2026

C
A
E E F E E D
A (t)
B
D
ACRYLIC FACED ILLUMINATED LOGO & LETTERS / LC-3W
Scale: 3/8” = 1’-0”
LOGO LETTERS SEAMS @
SIGN TYPE A B C D E F RETAINER T/C - RET. LOGO SQ.FT.
LL120/80 LC-3R 10’-0” 6’-8” 36’-9 1/2” 25’-11” 1’-8” 3’-4” 1” ½” RET 2 375.4
LL108/72 LC-3R 9’-0” 6’-0” 33’-1 1/4” 23’-4” 1’-6” 3’-0” 1” 1” T/C 2 304.1
LL96/64 LC-3R 8’-0” 5’-4” 29’-5” 20’-8 7/8” 1’-4” 2’-8” 1” 1” T/C 2 237.3
LL84/56 LC-3R 7’-0” 4’-8” 25’-9 1/4” 18’-1 3/4” 1’-2” 2’-4” 1” 1” T/C 2 184
LL72/48 LC-3R 6’-0” 4’-0” 22’-0 5/8” 15’-6 5/8” 1’-0” 2’-0” 1” 1” T/C 0 135.2
LL60/40 LC-3R 5’-0” 3’-4” 18’-4 3/4” 12’-11 1/2” 10” 1’-8” 1” 1” T/C 0 93.9
LL48/32 LC-3R 4’-0” 2’-8” 14’-8 3/4” 10’-4 3/8” 8” 1’-4” 1” 1” T/C 0 60
LL36/24 LC-3R 3’-0” 2’-0” 11’-0 3/4” 7’-9 3/8” 6” 1’-0” 1” 1” T/C 0 33.8
LL24/16 LC-3R 2’-0” 1’-4” 7’-4 1/2” 5’-2 1/4” 4” 8” 1” ¾” T/C 0 15
Approvals:
This is an original drawing created by Walton. It Revision: Signs will be manufactured with 120 or 277 Volts A/C. This sign is intended to be installed in
Client: TARGET is submitted for your personal use, however, it R1) 08/11/17 design intent change - LAH All Primary electrical service to the sign,and final accordance with the requirements of Sales: Date:
Address: X shall at all times remain the property of Walton. connection thereof, is the responsibility of the buyer. Article 600 of the National Electrical
It may be used in connection with the project All work is to be done in accordance with the purchase Code and/or other applicable local P.M.: Date:
City/State: X being planned for you by Walton, but not agreement attached hereto. In case of variance codes. This includes proper CIDFAMILY
HOUSE RH otherwise. You are not authorized to show between the specifications of the purchase agreement grounding and bonding of the sign. Design: Date:
Sales: Designer: these drawings to anyone outside your and this drawing, the drawing shall prevail.
Date: 06.28.22 PM JMD organization, nor is it to be reproduced, used, Client: Date:
copied or exhibited in any fashion. H: PAGE SIZE: 11” x 17”

6 1/2" MIN 5 1/2" MIN
C P3 1A 7" MAX C P3 1B 6" MAX
ILLUMINATION NOTES:
6" 5"
P3 2 P3 2
LED COLOR: RED (MINIMUM 635NM PEAK WAVELENGTH – MAXIMUM 660NM PEAK WAVELENGTH)
11 11
SLOAN PRISM 24V RED LED MODS
P3 4 D P3 5
12 12
5"
3”
3 3
THRU HOLE
3/4"
(6) 3/8” RIVNUT
1 1/4"
P2 6A P2 6B
1” x 2” PASS THRU
(6) 3/8” BOLT
7 7
.125 ALUMINUM PLATE
B 8 B 8 WELDED TO LETTER
RETURN AND BACK
1’-8” 1’-4”
9 9
.125 ALUMINUM
10 10
A A 1 1/8"
3/4"
LOGO SECTION MATCH PLATE
SECTION DETAIL @ LOGO/SYMBOL SECTION DETAIL @ LETTERS Scale: 1 1/2” = 1’-0”
1/8”
N.T.S. N.T.S. ASSEMBLY DETAIL AT LOGO SEAM
QTY: 2 PER SEAM Scale: Not to Scale
1” x 3/16” CLEAR
ACRYLIC GUIDE
3/4” FASTENER SCHEDULE
FOR USE WITH WOOD OR STUCCO WALL
1/4” BLUE & LAG SCREW SYSTEMS.
1-1/2” MIN PENETRATIONS (EXCL. TIP)
- TO DISPLAY RED DURING DAY / RED AT NIGHT
FOR USE WITH WOOD OR STUCCO WALL
3/8” 1/4” SNAP TOGGLE SYSTEMS.
MATERIALS: 1-1/2” MIN PENETRATIONS (EXCL. TIP)
FOR USE WITH WOOD OR EIFS WALL
# DESCRIPTION 1/4” LAG SCREW SYSTEMS.
1-1/2” MIN PENETRATIONS (EXCL. TIP)
1A .063 x 6” DEEP ALUMINUM RETURN FOR USE WITH WOOD OR EIFS WALL
FINISHES: 1/4” LAG & SHIELD SYSTEMS.
1B .040 x 5” DEEP ALUMINUM RETURN 1-1/2” MIN PENETRATIONS (EXCL. TIP)
2 SHORT SHANK FLAT HEAD STAINLESS STEEL SCREWS 1/4” DIA. THREADED FOR USE WITH WOOD, CONCRETE
ROD & BEARING PLATES BLOCK OR EIFS WALL SYSTEMS
3 3/16” LD MODIFIED ACRYLIC 2793 RED (ALTUGLAS OR EQUIV.) ACRYLIC SEAM DETAIL @ LOGO
4 1” .063 FABRICATED RETAINER Scale: 1” = 1’-0” 1/4” DIA. THREADED FOR USE WITH WOOD, CONCRETE
P1 P2 P3 ROD BLOCK OR EIFS WALL SYSTEMS
5 1” “J” PROFILE TRIM CAP MATTHEWS BRIGHT MATHEWS
SOA020SP WHITE MP3909 1/4” RED HEAD L.D.T. FOR USE WITH CONCRETE BLOCK,
TARGET WHITE TARGET RED (LARGE DIAMETER BRICK OR CONCRETE,
6A .080 ALUMINUM BACK (GLOSS) (GLOSS) EMBED A MIN OF 2 1/2”
TAPCON)
6B .063 ALUMINUM BACK 1/4” DIA. HILTI HIT ROD
FOR USE WITH CONCRETE,
NOTES: WITH Hy150 MAX EMBED A MIN. OF 2”
7 PAIGE L.E.D. TRANSFORMER BOX WITH POWER SUPPLY (OR EQUIVALENT) ADHESIVE
A. 1/4” WEEP HOLES WITH LIGHT BLOCKERS 2 PER LOW SPOT
8 PAIGE WALL BUSTER #980014 PASS THRU KIT with BUSHING B. SEAL PENETRATIONS WITH BASF-MASTER SEAL NP 150 (OR EQUIVALENT) 1/4” DIA. HILTI HIT ROD FOR USE WITH MASONRYAND BRICK
WITH Hy20 ADHESIVE EMBED A MIN. OF 3 3/8”
9 RED L.E.D.s PER “ILLUMINATION NOTES” C. ONE UL LABEL VISIBLE FROM GROUND, OTHERS ON TOP
UL LABEL LOCATION
D. CHANNEL LETTERS 60” & OVER REQUIRE 1/2” x 1” METAL RETAINER 1/4” DIA. HILTI HIT ROD FOR USE WITH CONCRETE BLOCK,
10 WATER PROOF LOCKABLE DISCONNECT SWITCH BY GC STD. BOTTOM LEFT CORNER WITH Hy20 ADHESIVE EMBED A MIN. OF 2”
11 MOUNTING SPACERS - 1” MAX / 1/2” MIN. STAND OFF o TOP OF LETTERS / NOT VISIBLE FOR USE WITH CONCRETE, MASONRY
o ü SEE NOTE 1/4” DIA. HILTI HLC AND BRICK
12 1/4” SS ATTACHMENT HARDWARE PER SITE CONDITIONS SLEEVE ANCHOR EMBED A MIN. OF 3 3/8”
Approvals:
This is an original drawing created by Walton. It Revision: Signs will be manufactured with 120 or 277 Volts A/C. This sign is intended to be installed in
Client: TARGET is submitted for your personal use, however, it R1) 08/11/17 design intent change - LAH All Primary electrical service to the sign,and final accordance with the requirements of Sales: Date:
Address: X shall at all times remain the property of Walton. connection thereof, is the responsibility of the buyer. Article 600 of the National Electrical
It may be used in connection with the project All work is to be done in accordance with the purchase Code and/or other applicable local P.M.: Date:
City/State: X being planned for you by Walton, but not agreement attached hereto. In case of variance codes. This includes proper CIDFAMILY
HOUSE RH otherwise. You are not authorized to show between the specifications of the purchase agreement grounding and bonding of the sign. Design: Date:
Sales: Designer: these drawings to anyone outside your and this drawing, the drawing shall prevail.
Date: 06.28.22 PM JMD organization, nor is it to be reproduced, used, Client: Date:
copied or exhibited in any fashion. H: PAGE SIZE: 11” x 17”

5 1/2" MIN
D P3 1 6" MAX
ILLUMINATION NOTES:
5"
P3 2
LED COLOR: WHITE 6500K
11
SLOAN PRISM 24V 6500K WHITE LED MODS
P3 5
LED COLOR: RED (MINIMUM 635NM PEAK WAVELENGTH – MAXIMUM 660NM PEAK WAVELENGTH)
12
SLOAN PRISM 24V RED LED MODS
A 3
4
D
P2 6
7
C B
A
C 8
9
ACRYLIC FACED ILLUMINATED LETTERS 10
Scale: 1/4” = 1’-0”
B
SIGN TYPE A B C D SQ. FT.
DriveUp16-R 16” 1’-9 3/8” 2’-9 3/4” 12’-2 7/8” 34.17
SECTION DETAIL @ LETTERS
DriveUp18-R 18” 2’-0” 3’-1 7/8” 13’-9 1/4” 43.46 N.T.S.
DriveUp20-R 20” 2’-2 3/4” 3’-6 1/8” 15’-3 5/8” 46.06
FASTENER SCHEDULE
DriveUp24-R 24” 2’-8” 4’-2 1/2” 18’-4 1/8” 77.33 FOR USE WITH WOOD OR STUCCO WALL
1/4” BLUE & LAG SCREW SYSTEMS.
1-1/2” MIN PENETRATIONS (EXCL. TIP)
FOR USE WITH WOOD OR STUCCO WALL
1/4” SNAP TOGGLE SYSTEMS.
1-1/2” MIN PENETRATIONS (EXCL. TIP)
FOR USE WITH WOOD OR EIFS WALL
1/4” LAG SCREW SYSTEMS.
1-1/2” MIN PENETRATIONS (EXCL. TIP)
MATERIALS:
FOR USE WITH WOOD OR EIFS WALL
FINISHES: 1/4” LAG & SHIELD SYSTEMS.
# DESCRIPTION 1-1/2” MIN PENETRATIONS (EXCL. TIP)
1 .040 x 5” DEEP ALUMINUM RETURN 1/4” DIA. THREADED FOR USE WITH WOOD, CONCRETE
ROD & BEARING PLATES BLOCK OR EIFS WALL SYSTEMS
2 SHORT SHANK FLAT HEAD STAINLESS STEEL SCREWS CAR LOGO COLORS
3 3/16” LD MODIFIED ACRYLIC 7328 WHITE 1/4” DIA. THREADED FOR USE WITH WOOD, CONCRETE
P1 P2 P3 Target Red DARK RED DARK GRAY LIGHT GRAY ROD BLOCK OR EIFS WALL SYSTEMS
4 3/16” LD MODIFIED ACRYLIC 2793 RED MATTHEWS BRIGHT MATHEWS PMS 186 PMS 188 PMS 425 PMS 421
SOA020SP WHITE MP3909 1/4” RED HEAD L.D.T. FOR USE WITH CONCRETE BLOCK,
TARGET WHITE TARGET RED (LARGE DIAMETER BRICK OR CONCRETE,
5 1” “J” PROFILE TRIM CAP (GLOSS) (GLOSS) EMBED A MIN OF 2 1/2”
TAPCON)
6 .063 ALUMINUM BACK 1/4” DIA. HILTI HIT ROD
FOR USE WITH CONCRETE,
NOTES: WITH Hy150 MAX EMBED A MIN. OF 2”
7 PAIGE POWER SUPPLY BOX WITH POWER SUPPLY (OR EQUIVALENT) ADHESIVE
A. DIGITAL PRINT VINYL APPLIED FIRST SURFACE AT LOGO
8 PAIGE WALL BUSTER #980014 PASS THRU KIT with BUSHING B. 1/4” WEEP HOLES WITH LIGHT BLOCKERS 2 PER LOW SPOT 1/4” DIA. HILTI HIT ROD FOR USE WITH MASONRYAND BRICK
WITH Hy20 ADHESIVE EMBED A MIN. OF 3 3/8”
9 RED L.E.D.s PER “ILLUMINATION NOTES” C. SEAL PENETRATIONS WITH BASF-MASTER SEAL NP 150 (OR EQUIVALENT)
UL LABEL LOCATION
D. ONE UL LABEL VISIBLE FROM GROUND, OTHERS ON TOP 1/4” DIA. HILTI HIT ROD FOR USE WITH CONCRETE BLOCK,
10 WATER PROOF LOCKABLE DISCONNECT SWITCH BY GC STD. BOTTOM LEFT CORNER WITH Hy20 ADHESIVE EMBED A MIN. OF 2”
11 MOUNTING SPACERS - 1” MAX / 1/2” MIN. STAND OFF o TOP OF LETTERS / NOT VISIBLE FOR USE WITH CONCRETE, MASONRY
o ü SEE NOTE 1/4” DIA. HILTI HLC AND BRICK
12 1/4” SS ATTACHMENT HARDWARE PER SITE CONDITIONS SLEEVE ANCHOR EMBED A MIN. OF 3 3/8”
Approvals:
This is an original drawing created by Walton. It Revision: Signs will be manufactured with 120 or 277 Volts A/C. This sign is intended to be installed in
Client: TARGET is submitted for your personal use, however, it R1) 08/11/17 design intent change - LAH All Primary electrical service to the sign,and final accordance with the requirements of Sales: Date:
Address: X shall at all times remain the property of Walton. connection thereof, is the responsibility of the buyer. Article 600 of the National Electrical
It may be used in connection with the project All work is to be done in accordance with the purchase Code and/or other applicable local P.M.: Date:
City/State: X being planned for you by Walton, but not agreement attached hereto. In case of variance codes. This includes proper CIDFAMILY
HOUSE RH otherwise. You are not authorized to show between the specifications of the purchase agreement grounding and bonding of the sign. Design: Date:
Sales: Designer: these drawings to anyone outside your and this drawing, the drawing shall prevail.
Date: 06.28.22 PM JMD organization, nor is it to be reproduced, used, Client: Date:
copied or exhibited in any fashion. H: PAGE SIZE: 11” x 17”

WINDOW DIMENSIONS VARIES
SQ. FT
SIGN TYPE (1 BOX)
OPU-SV7-W VINYL 7.6sf
NOTE: WINDOW DIMENSION VARIES ADJUST TO FIELD CONDITIONS
VARIES
3'-6 1/2"
DIMENSIONS
WINDOW
7"
2'-2"
V1 A
1st SURFACE OPAQUE WHITE VINYL
Scale: 1” = 1’-0”
FINISHES:
V1
WHITE 25% of window area based
3M 7725-10
on 272 SF of window area =
68 SF of window signage
NOTES:
A. VINYL APPLIED FIRST SURFACE allowed
Approvals:
This is an original drawing created by Walton. It Revision: Signs will be manufactured with 120 or 277 Volts A/C. This sign is intended to be installed in
Client: TARGET is submitted for your personal use, however, it R1) 08/11/17 design intent change - LAH All Primary electrical service to the sign,and final accordance with the requirements of Sales: Date:
Address: X shall at all times remain the property of Walton. connection thereof, is the responsibility of the buyer. Article 600 of the National Electrical
It may be used in connection with the project All work is to be done in accordance with the purchase Code and/or other applicable local P.M.: Date:
City/State: X being planned for you by Walton, but not agreement attached hereto. In case of variance codes. This includes proper CIDFAMILY
HOUSE RH otherwise. You are not authorized to show between the specifications of the purchase agreement grounding and bonding of the sign. Design: Date:
Sales: Designer: these drawings to anyone outside your and this drawing, the drawing shall prevail.
Date: 06.28.22 PM JMD organization, nor is it to be reproduced, used, Client: Date:
copied or exhibited in any fashion. H: PAGE SIZE: 11” x 17”

Main ID Logo - Face Lit Horizontal
C
3”
D E F
A
G
B
Sign Elevation - Front View
A
Scale: N.T.S.
3”
ALUMINUM RETURN typ. CHANNEL
LOCK OR RIVET
PAN HEAD SCREW
TRIM CAP STEEL ANGLE
WELD-ON 16 & RESIN BOND S.S. THREADED ROD w/
OR CHANNEL BOND HEX NUT & LOCK
WASHER
TYPE A B C D E F G SQ.FT.
SPACER (OPTIONAL)
IL-15-CL-L 15" 9 1/16" 11'-9 1/8" 1'-7 1/16" 3'-5 1/4" 6'-3 3/8" 1'-6 7/8" 14.70 TO NEXT
LETTER
- 3” deep .040 alum. returns pre-finished Hunter Red IL-16-CL-L 16 7/8" 10 3/16" 13'-2 13/16" 1'-9 7/16" 3'-10 7/16" 7'-0 3/4" 1'-9 1/4" 18.60
60” or > .063 alum. returns
IL-18-CL-L 18 3/4" 11 5/16" 14'-8 7/16" 1'-11 13/16" 4'-3 9/16" 7'-10 3/16" 1'-11 5/8" 22.97
IL-22-CL-L 22 1/2" 1'-1 9/16" 17'-7 11/16" 2'-4 9/16" 5'-1 7/8" 9'-5 1/16" 2'-4 3/8" 33.08 18ga. PLTC WIRE
IL-28-CL-L 28 1/4" 1'-5 1/16" 22'-1 13/16" 2'-11 7/8" 6'-5 11/16" 11'-9 15/16" 2'-11 5/8" 52.15 CRIMP CONNECTOR
IL-33-CL-L 33 3/4" 1'-8 3/8" 26'-5 9/16" 3'-6 7/8" 7'-8 13/16" 14'-1 9/16" 3'-6 1/2" 93.86
IL-39-CL-L 39 1/2" 1'-11 7/8" 30'-11 11/16" 4'-2 3/16" 9'-0 5/8" 16'-6 7/16" 4'-1 3/4" 101.96
IL-45-CL-L 45 1/8" 2'-3 1/4" 35'-4 5/8" 4'-9 5/16" 10'-4 1/8" 18'-10 11/16" 4'-8 7/8" 133.06 3/16" THICK PLASTIC FACE
Colors & Materials ALUMINUM BACK
Channel Letter Key POWER SUPPLY 3/13/25
LED MODULE 12ga. STRANDED THHN
PLASTIC BUSHING WIRE, FITTING, &
STUD FOR ELECTRICAL GROUNDING CONDUIT (TO PRIMARY)
JUNCTION BOX JUNCTION BOX
ELECTRICAL CONDUIT & FITTING WIRE NUT
Ø3/8" ALUMINUM RIV-NUT
SILICONE CAULK (APPLIED TO
ALL WALL PENETRATIONS)
Ø5/16" DRAIN HOLE w/LIGHT
BAFFLE (when necessary)
Typical Section - Face Lit Letter Flush Mounted & Self Contained
2