DRC_EXHIBITS_HOWE_STREET_PROPERTY_011326.PDF
City of Tempe — Development Review Commission Regular Meeting (2026-01-13)
Extracted text (via pymupdf)
11985 characters
EXHIBITS for HOWE STREET PROPERTY (PL250402) 1. Zoning Map (Exhibit 1) 2. Aerial Map (Exhibit 2) 3. Letter of Explanation (Exhibit 3) 4. Site Plan (Exhibit 4) 5. Floor Plan (Exhibits 5 and 6) 6. Building Elevations (Exhibit 7) 7. Site Context Photos (Exhibits 8-17) HOWE STREET PROPERTY .. Single-Family Residential (R1-6) .. Multi-Family Residential (R-2) • • • Multi-Family Residential Restricted (R-3R) PL250402 ;, -- ! ' I I r:ril 11. Tempe s ....... ....... ••••• ....... ....... , .. , . ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... EXHIBIT 1 SITE R1-6 HOWE STREET PROPERTY Aerial Map EXHIBIT 2 PL250402 Trinity Home Investments LLC 620 W Howe St Tempe, AZ 85281 Attention: City of Tempe- Permits and Planning To Whom it May Concern, This letter is an explanation for an application of a USE PERMIT at the following property: 620 W. Howe St, Tempe, AZ 85282. This property was purchased in May of 2024. We have gone through all our inspections. Upon the final inspection, it was discovered that a use permit is needed for an additional parking spot in the driveway. The current home has a one car enclosed garage and a driveway. Based on the approval of the Zoning and Development Code Section 6-308 the following applies: a. Any significant vehicular or pedestrian traffic in adjacent areas; No the permit will not have any additional vehicular or pedestrian traffic to the adjacent area. There is enough room in the garage and driveway without disruption. b. Nuisance arising from the emission of odor, dust, gas, noise, vibration, smoke, heat or glare at a level exceeding that of ambient conditions; No the permit will not emit any odor, dust, gas noise, vibration, smoke, heat or glare affecting neighboring residents. c. Contribution to the deterioration of the neighborhood or to the downgrading of property values which is conflict with the goals, objectives or policies of the city’s adopted plans for General plan. No, the permit will not contribute to any deterioration of the neighborhood nor will it downgrade property values. The home has been completely remodeled and currently is under contract for a price of $725,000. Which in a much higher price than many if not most of the neighboring surrounding houses. d. Compatibility with existing surrounding structures and uses; This permit will be compatible with the home and surrounding structures of the neighborhood. e. Adequate control of disruptive behavior both inside and outside the premises, which may create a nuisance to the surrounding area or general public; this home will not contribute to any disruptive behavior both inside and outside the property. We look forward to your approval of this use permit to receive a final certificate of occupancy at this beautiful newly renovated home in Tempe. Thank you for your consideration. With Respect, Brian Kingdeski Manager/Member Trinity Investment Homes LLC EXHIBIT 3 PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL PL 11' ENGINEER DRAFTER DESCRIPTION: FAST LANE DESIGNS 1340 E BETH DR. PHX AZ 85042 602 348 9319 620 W HOWE ST TEMPE AZ 85281 PL250335 TRINITY HOMES USE PERMIT REQUEST PARKING SPACE IN FRONT YARD SETBACK CS REV A LEGEND (N) - NEW CONSTRUCTION (E) - EXISTING CONSTRUCTION B.S.L. - BUILDING SETBACK LINE P.U.E. - PUBLIC UTILITY EASEMENT W - WATER METER E - ELECTRIC METER PROJECT DATA: ADDRESS: 620 HOWE ST ZONING: R1-6 LOT AREA: 7980 SQ. FT. APN 124-67-148 AREA: FIRST FLOOR LIVABLE: 1003 SQ. FT. LIVABLE TO GARAGE: 200 SQ. FT. PROPOSED ADDITION: 1376 SQ. FT PROPOSED REMODEL: 300 SQ FT. TOTAL: 2376 SQ. FT. LOT COVERAGE: (%) PROPOSED: 29% CL - CENTER LINE OF STREET HOWE ST PL - PROPERTY LINE EXISTING RESIDENCE G - GAS METER SITE PLAN - SCALE = 1"=10' NOTES: 1. NEW 1/2" TYPE X GYP. BD. AT ALL WALLS. 2. WHERE NEW WALL ABUTS EXISTING WALL, THE WALL SHALL BE ALIGNED SO THAT NEW GYP. BD. SHALL CO-PLANE (FLUSH) WITH NEW GYP. BD. OVER-LAYED ON EXISTING WALL. 3. PORTION OF ROOF WITHIN 5' OF PROPERTY LINE TO BE 1HR FIRE RATED USING 5/8' TYPE X GYP BOARD UNDERNEATH WITH 2X FIREBLOCKING BETWEEN TRUSSES FROM TOP PLATE TO ROOF DECK. SHINGLE TO BE CLASS A PRODUCT PER IRC TABLE R302.1(1). GENERAL SITE NOTES: A) PROPERTY BOUNDARIES AND SETBACK LOCATIONS AND UTILITY LOCATIONS SHALL BE VERIFIED BY BUILDER PRIOR TO CONSTRUCTION B) GRADE CONDITIONS AND ELEVATIONS SHALL BE VERIFIED BY BUILDER PRIOR TO CONSTRUCTION DEFERRED SUBMITTAL: ROOF TRUSS CALCULATION GENERAL SITE NOTES: 1. ALL PRODUCTS LISTED BY AN EVALUATION SERVICE REPORT (ESR) SHALL BE INSTALLED PER THE REPORT AND THE MANUFACTURES WRITTEN INSTRUCTIONS. PRODUCT SUBSTITUTIONS SHALL ALSO BE LISTED BY AN ESR. 2. FOUNDATION & FOOTING DEPTH SHALL BE A MINIMUM OF 18 INCHES BELOW GRADE (OR PER PROPERTY SOIL PROVIDE A MINIMUM OF 3 INCH CLEARANCE BETWEEN REBAR AND SOIL. (R403.1 AMENDED) 3. EXTERIOR WALL PENETRATIONS BY PIPES, DUCTS OR CONDUITS SHALL BE SEALED. (R703.1) 4. WOOD SILL PLATES SHALL BE PRESSURE TREATED OR DECAY RESISTANT. EXTERIOR SILL PLATES SHALL BEAR A MINIMUM OF 6 INCHES ABOVE FINISH GRADE. (R317.1) 5. GYPSUM BOARD APPLIED TO A CEILING SHALL BE 1/2” WHEN FRAMING MEMBERS ARE 16” O.C. OR 5/8” WHEN FRAMING MEMBERS ARE 24” O.C. OR USE LABELED 1/2” SAG-RESISTANT 6. THE BUILDING THERMAL ENVELOPE SHALL COMPLY WITH CLIMATE ZONE 5. ENERGY COMPLIANCE SHALL BE DEMONSTRATED BY THE FOLLOWING PRESCRIPTIVE VALUES (TABLE N1102.1.2): i. PRESCRIPTIVE MINIMUM R-VALUES : <CEILING=R-38> / < WALLS=R-13> ii. PRESCRIPTIVE MAXIMUM WINDOW FENESTRATION VALUES: <U-FACTOR=0.40> / <SHGC=0.25> 7. GENERAL PURPOSE 15- AND 20-AMPERE RECEPTACLES SHALL BE LISTED TAMPER-RESISTANT. (E4002.14) 8. RECEPTACLE OUTLETS SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6 FEET, MEASURED HORIZONTALLY, FROM AN OUTLET IN THAT SPACE, INCLUDING ANY WALL SPACE 2 FEET OR MORE IN WIDTH. (E3901.2) TABLE OF CONTENTS: CS EXISTING PLAN & SITE PLAN A1 EXISTING/ PROPOSED FLOOR PLAN, ELEVATION A2 FOUNDATION, A3 MECHANICAL A4 ELECTRICAL A5 PLUMBING A6 FRAMING A7 DETAILS PROJECT DESCRIPTION: USE PERMIT REQUEST PARKING SPACE IN FRONT YARD SETBACK VICINITY MAP- SCALE = NTS E W CL ALL BUILDING IN ACCORDANCE TO 2017 NEC 2018 IRC 2018 IFC 2018 IBC & CITY OF TEMPE APPLICABLE CODES CL EXISTING GARAGE PARKING ADDITION CL 57' 140' 52' 21' 10' 5' 20' BSL 25' BSL 10' BSL 5' BSL 18' 24' FENCE SIDEWALK TREE REQUIRED WITHIN 5' TO PROVIDE SHADE 25' ROW 4' EXISTING SINGLE FAMILY RESIDENCE EXISTING SINGLE FAMILY RESIDENCE ALLEY 11' 20' PROPOSED DRIVEWAY PARKING EXHIBIT 4 5'-5" X 4'-11" 9'-11" X 9'-11" 4'-11" X 7'-8" 9'-11" X 9'-9" 10'-11" X 9'-11" 12'-11" X 10'-0" 14'-9" X 19'-11" 10'-11" X 5'-11" 15'-4" X 17'-7" 11'-11" X 19'-11" 10'-11" X 5'-3" 10'-7" X 10'-1" 7'-11" X 9'-7" 11'-11" X 13'-8" 5'-2" X 4'-11" 11'-11" X 5'-2" LAUNDRY BEDROOM BEDROOM BEDROOM EXISTING BATH PANTRY POWDER BATH BEDROOM OWNERS SUITE OWNERS BATH CLOSET OFFICE KITCHEN LIVING FAMILY 4040LS 4040LS 4040LS 5068 5068 2840DH 2840DH 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 8' CLG 1'-6" 1'-6" WH DRYER WASHER FRIDGE RANGE DISPOSAL 2668 2668 2668 2668 2868 2668 2668 2668 2668 2668 2868 3068 2868 2668 5068 BI-PASS 5068 BI-PASS 11'-4" X 12'-10" 9'-11" X 10'-3" 20'-7" X 16'-8" 10'-10" X 11'-11" 9'-11" X 9'-9" 14'-10" X 7'-11" 5'-5" X 7'-11" LIVING BEDROOM BEDROOM KITCHEN DINING DEN BATH FLOOR PLAN KEYNOTES 1 NEW 2X4 WALL W/ STUDS @ 24" OC INTERIOR WALLS 2 NEW 2X6 WALL W/ STUDS @ 16" OC 3 EXTG CMU WALL TO REMAIN & FURRED OUT WITH GYP BOARD 4 NEW WATER CLOSET (ALLOW MIN 15" TO EA SIDE & 24" TO FRONT) 5 NEW LAV 6 STUCCO W/ FULL SHEATHING & ONE LAYER OF No 15 ASPHALT FELT PER R703.7 7 NEW COMP SHINGLES W/ FLASHING 8 ROOF ATTIC VENT 9 NEW TILE SHOWER W/ WATERPROOF FIBER CEMENT BACKER BOARD (ASTM C1278) ENGINEER DRAFTER DESCRIPTION: FAST LANE DESIGNS 1340 E BETH DR. PHX AZ 85042 602 348 9319 620 W HOWE ST TEMPE AZ 85281 PL250335 TRINITY HOMES USE PERMIT REQUEST PARKING SPACE IN FRONT YARD SETBACK A1 REV A PROPOSED FLOORPLAN - SCALE = 1/4" = 1' EXISTING FLOORPLAN - SCALE = 1/4" = 1' EXISTING LOAD BEARING WALL TO BE DEMO AND REPLACED WITH 5.5X10.5 GLU LAM BEAM PROPOSED FRONT ELEVATION - SCALE = 1/8" = 1' 1 1 2 2 3. PROVIDE FURRING TO ALLOW RECEPS 4 4 5 5 5 PROPOSED WEST ELEVATION - SCALE = 1/8" = 1' 8'-6"TOP 12' PROPOSED REAR ELEVATION - SCALE = 1/8" = 1' PROPOSED EAST ELEVATION - SCALE = 1/8" = 1' 6 7 WALLS TO BE DEMOLISHED LEGEND 9 SOLID CORE SELF CLOSING DOOR REQURIED AT GARAGE 1 HR FIRE RATED MATERIAL & BLOCKING REQUIRED AT GARAGE WALL. 15' 19'-6" 28'-6" 64'-6" 22' 6' 9'-6" 14'-6" 53' 9'-6" 2' 10' 5'-6" 9'-6" 13' 0" 2' 15'-6" 11' 4' 4' 12' 14' 5' 12' 3' 5'-6" 8 NEW DIRECT TO STUD SHOWER STALL KIT 1'-6" 1'-6" 1'-6" 1'-6" ALL APPLIANCES WILL BE LABELED FOR ENERGY SOURCE. SAFETY GLAZING SHALL BE PROVIDED IN ALL HAZARDOUS AREA AS OCCURS - R308.4 PROVIDE FLASHING AT WINDOWS PER R703.4 4' 4' 4' FRAMED INFILL WITH STUCCO EXTERIOR 12 4 ADDRESS EXHIBIT 5 ATTIC VENT CALCULATION 2376 SQ FT. /300 = 7.92 SQ FT. REQUIRED O'HAG VENTS (6) X 0.49 = 2.94 36X24 RECTANGLE VENT (2) X 3 = 6 TOTAL= 8.94 SQ FT. PROVIDED ..\..\..\..\2FLD\4Floor Plans\1Completed BEAM SCHEDULE MARK SIZE RECOMMENDED CAMBER B1 5 1 2" X 7 1 2" GLB C=STD B2 5 1 2" X 10" GLB C= 1 2" ENGINEER DRAFTER DESCRIPTION: FAST LANE DESIGNS 1340 E BETH DR. PHX AZ 85042 602 348 9319 620 W HOWE ST TEMPE AZ 85281 PL250335 TRINITY HOMES USE PERMIT REQUEST PARKING SPACE IN FRONT YARD SETBACK A6 REV A NOTES: ATTIC VENT & CALCULATIONS 1/300 W/ 40%-50% LOCATED IN UPPER VENTS. HIGH VENTS SHALL BE LOCATED NO MORE THAN 3 FT BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE. 1/16" - 1/4" CORROSION- RESISTANT WIRE MESH. 2X4 PRE FAB TRUSSES @ 24" OC. TRUSSES TO LAND ON NEW 2X6 EXTERIOR WALL USING SIMPSON STRONG TIE & H2.5 FASTENER. RAFTER COMPANY TO VERIFY DIMENSIONS & PITCH ON FIELD PRIOR TO CONSTRUCTION OF NEW RAFTERS. (2) 2X8 WOOD HEADER AT 5' WINDOW (2) 2X6 WOOD HEADER AT 4' WINDOW (2) 2X8 HEADER AT SLIDING DOOR FIRE SHELL COATING AT EXPOSED FOAM BOARD TO ATTIC AND CRAWL SPACES. EXISTING TRUSS ROOF TO REMAIN NEW 2X4 PRE ENGINEERED TRUSSES @ 24" OC NAILING SCHEDULE PROPOSED FRAMING PLAN - SCALE = 1/4" = 1' PITCH 4/12 PITCH 4/12 NEW 2X6 @ 16" OC BEARING WALLS (TYP) 31'-6" 19'-6" 46'-6" 40'-6" 20'-6" PITCH 4/12 PITCH 4/12 1 A7 PITCH 4/12 PITCH 4/12 NEW 2X4 PRE ENGINEERED TRUSSES @ 24" OC B2 B1 15' 10' NEW 2X4 @ 16" OC INTERIOR WALLS (TYP) (3) 2X4 WOOD POSTS 201 201 PITCH 4/12 PITCH 4/12 22x30 ATTIC ACCESS CROSS SECTION - SCALE = N.T.S NEW 2x4 ENGINEERED TRUSSES @ 24" OC NEW 2X6 WOOD STUDS @ 16" OC R19 BATT INSULATION R38 BATT INSULATION 5 8" GYP BOARD (TYP) CONTINUOUS 3 8" SHEATHING TO ROOF W/ STUCCO 1/2" GYP BOARD (TYP) 2X6 DOUBLE TOP PLATE H25A AT EACH RAFTER & WALL 2X6 BLOCKING @ 4' AFF CONC TILE ROOF W/ APPROVED UNDERLAYMENT 5 8" PLYWOOD TYP 2X6 PRESSURE TREATED BOTTOM PLATE EXHIBIT 6 FLOOR PLAN KEYNOTES 1 NEW 2X4 WALL W/ STUDS @ 24" OC INTERIOR WALLS 2 NEW 2X6 WALL W/ STUDS @ 16" OC 3 EXTG CMU WALL TO REMAIN & FURRED OUT WITH GYP BOARD 4 NEW WATER CLOSET (ALLOW MIN 15" TO EA SIDE & 24" TO FRONT) 5 NEW LAV 6 STUCCO W/ FULL SHEATHING & ONE LAYER OF No 15 ASPHALT FELT PER R703.7 7 NEW COMP SHINGLES W/ FLASHING 8 ROOF ATTIC VENT 9 NEW TILE SHOWER W/ WATERPROOF FIBER CEMENT BACKER BOARD (ASTM C1278) ENGINEER DRAFTER DESCRIPTION: FAST LANE DESIGNS 1340 E BETH DR. PHX AZ 85042 602 348 9319 620 W HOWE ST TEMPE AZ 85281 PL250335 TRINITY HOMES USE PERMIT REQUEST PARKING SPACE IN FRONT YARD SETBACK A1 REV A PROPOSED FRONT ELEVATION - SCALE = 1/8" = 1' PROPOSED WEST ELEVATION - SCALE = 1/8" = 1' 8'-6"TOP 12' PROPOSED REAR ELEVATION - SCALE = 1/8" = 1' PROPOSED EAST ELEVATION - SCALE = 1/8" = 1' 6 7 8 12 4 ADDRESS EXHIBIT 7 EXHIBIT 8 EXHIBIT 9 EXHIBIT 10 EXHIBIT 11 EXHIBIT 12 EXHIBIT 13 EXHIBIT 14 EXHIBIT 15 EXHIBIT 16 EXHIBIT 17