Sweeper - grant award list
Extracted text (via pymupdf)
51414 characters
March 14, 2025 Ms. Crystal Dyches, Manager City of El Mirage 10000 North El Mirage Road El Mirage, Arizona 85335 Dear Ms. Dyches: On March 7, 2025, the Maricopa Association of Governments (MAG) received notification from the Arizona Department of Transportation (ADOT) that the agreement for the transposition of federal Congestion Mitigation and Air Quality Improvement (CMAQ) funds for MAG Highway User Revenue Funds has been completed for the Prioritized List of Proposed PM-10 Certified Street Sweepers for FY 2025. On December 4, 2024, the MAG Regional Council approved the Prioritized List of Proposed PM-10 Certified Street Sweepers for FY 2025 CMAQ Funding. One PM-10 certified street sweeper project requested by the City of El Mirage has been approved for FY 2025 funding for an amount not to exceed $341,973 (see Attachment One). The City of El Mirage may proceed with the purchase of the proposed street sweeper project for FY 2025. In the project application, the City of El Mirage agreed to provide a 5.7 percent cash match. We are requesting that the FY 2025 street sweeper be purchased and the reimbursement request be sent to MAG by March 14, 2026. For the FY 2025 street sweepers, MAG member agencies may procure their own street sweepers. Reimbursement requests are to be sent to MAG. After MAG reviews the reimbursement request, MAG will send the reimbursement documentation to ADOT and then ADOT will issue the reimbursement check to the member agencies. Additional details are provided below. 1. Eligibility - Eligible street sweepers are defined as those which have been certified by the South Coast Air Quality Management District (SCAQMD) as meeting the SCAQMD Rule 1186 certification standards. The most recent list of Certified Street Sweepers Under SCAQMD Rule 1186 is dated July 10, 2024 (see Attachment Two). It is important to note that not all sweepers on the list are eligible for funding. At this time, the MAG street sweeper program will continue to fund only conventionally fueled vehicles to reduce PM-10. Ms. Crystal Dyches, Manager March 14, 2025 Page 2 It is assumed that, at a minimum, the grant funded street sweepers will be used in accordance with the lane miles and sweeping cycle submitted with the project applications. 2. Procurement – MAG member agencies may procure their own PM-10 certified street sweepers. The procurement of the street sweepers must conform to applicable state and local procurement regulations for the purchase of the certified street sweeper. In March 2025, ADOT completed the transposition of federal CMAQ funds for MAG Highway User Revenue Funds for the Prioritized List of Proposed PM-10 Certified Street Sweepers for FY 2025. 3. Annual Inventory - According to ADOT policy, MAG is responsible for conducting and submitting an annual inventory of the certified street sweepers owned by the jurisdictions to ADOT by October 31. For the annual inventory, MAG will contact the jurisdictions to obtain information on each street sweeper. 4. Reimbursement - MAG is requesting that the street sweeper be purchased and the reimbursement request be sent to MAG by March 14, 2026. Since ADOT determined that there are no street sweeper manufacturers that can meet FHWA’s Buy America requirements, the federal CMAQ funds have been transposed to Highway User Revenue Funds for reimbursement to the member agencies. Additional costs for equipment beyond the specifications necessary for compliance with Rule 1186-certification are not eligible for reimbursement. Examples of additional street sweeper equipment not eligible for reimbursement are provided in Attachment Three. Within 30 days after payment for the street sweeper, submit a copy of the vendor invoice along with all back-up documentation to the attention of Dean Giles at MAG. MAG will review the reimbursement request, ADOT Payment Report Form, and send the invoice documentation to ADOT and ADOT will reimburse the City of El Mirage for an amount not to exceed $341,973 for the FY 2025 sweeper. Documentation that includes a description of the street sweeper, the vehicle identification number, name of title holder, the cost of the vehicle (copy of invoice with detailed cost information on optional equipment, bill of sale, etc.), and the location where the sweeper is kept when it is not in use, should be provided. Also, please provide the name of the contact person for the sweeper and telephone number. Ms. Crystal Dyches, Manager March 14, 2025 Page 3 5. Disposition – The ADOT Federal Property Management Standards (see Attachment Four) requires that each jurisdiction obtain ADOT approval prior to disposal of a grant funded street sweeper. Each jurisdiction is to request disposal of a street sweeper in writing to MAG. MAG will send the request to ADOT, and MAG will in turn forward the ADOT response back to the jurisdiction. For disposal of an older grant funded street sweeper through any means, the federal awarding agency is entitled to a share of the proceeds. According to the ADOT Federal Property Management Standards for disposition through a trade-in or sale, an amount of the proceeds entitled to the federal awarding agency will be calculated and applied toward the cost of the new street sweeper and an amount based on the percentage of the jurisdiction’s participation in the original sweeper may be used to offset the amount of local cash match required. On December 4, 2024, the MAG Regional Council approved the prioritized list of proposed PM-10 certified street sweeper projects for FY 2025 CMAQ funding. Also, on January 22, 2025, the MAG Regional Council approved the FY 2025 Closeout Programming that includes an additional $2,355,757 in FY 2025 CMAQ funding for street sweepers on the prioritized list. If you have any questions or require additional information, please contact Dean Giles at 602-452-5013 or dgiles@azmag.gov. Sincerely, Ed Zuercher Executive Director cc: Cason Chambers, Operations Superintendent, El Mirage Nick Russo, Public Works Director, El Mirage Amber Wakeman, Intergovernmental Affairs Director, El Mirage 1 Prioritized List of Proposed PM-10 Certified Street Sweeper Projects for FY 2025 CMAQ Funding Approved by the MAG Regional Council on December 4, 2024 $1,380,000 in CMAQ Funding is Available for Sweeper Projects +++ Supplemental Information Agency Federal Cost Local Cost Total Cost * Daily Emission Reduction (Kilograms /day) Cost- Effectiveness (CMAQ dollar cost per annual metric ton reduced) The requested certified street sweeper will: Have local resources been committed such as staff or equipment to support the operation of the sweeper? Please indicate in what geographical area(s) the requested certified street sweeper will operate Number of certified street sweepers owned and operated by your agency. ** Replace non- certified sweeper Expand Area Swept Increase Sweeping Frequency Replace older certified sweeper Yes No Peoria $363,644 $21,981 $385,625 287 $494 Northern Ave. to SR 74; 67th Ave. to 138th Ave. 7 Phoenix #2 $390,624 $23,611 $414,235 245 $621 Camelback Rd. to Pinnacle Peak Rd.; 51st Ave. to 16th St. 35 Phoenix #1 $390,624 $23,611 $414,235 214 $713 Estrella Dr. to Camelback Rd.; 107th Ave. to Central Ave. 35 El Mirage $341,973 $20,671 $362,644 143 $934 Northern Ave. to Thompson Ranch Rd.; Dysart Rd. to the Agua Fria riverbed 2 Subtotal $1,486,865 Amount Available $1,380,000 Balance ($106,865) Attachment One 2 Supplemental Information Agency Federal Cost Local Cost Total Cost * Daily Emission Reduction (Kilograms /day) Cost- Effectiveness (CMAQ dollar cost per annual metric ton reduced) The requested certified street sweeper will: Have local resources been committed such as staff or equipment to support the operation of the sweeper? Please indicate in what geographical area(s) the requested certified street sweeper will operate Number of certified street sweepers owned and operated by your agency. ** Replace non- certified sweeper Expand Area Swept Increase Sweeping Frequency Replace older certified sweeper Yes No Surprise $392,143 $23,703 $415,846 93 $1,641 Jomax Rd. to Peoria Ave.; 163rd Ave. to Dysart Rd. 8 Buckeye #1 $349,488 $21,125 $370,613 59 $2,301 Citywide in the PM-10 nonattainment area 8 Chandler $369,677 $22,345 $392,022 53 $2,723 Elliot Rd. to Germann Rd.; Alma School Rd. to Gilbert Rd. 10 Mesa $416,464 $25,173 $441,637 57 $2,868 Price Rd. to Gilbert Rd.; Brown Rd. to Elliot Rd. 7 Tempe $377,358 $22,810 $400,168 50 $2,950 48th St. to Evergreen Rd.; Continental Dr. to Warner Rd. 6 Paradise Valley $371,632 $22,463 $394,095 35 $4,088 Townwide 2 Buckeye #2 $349,488 $21,125 $370,613 9.3 $14,606 Citywide in the PM-10 nonattainment area 8 Pinal County #2 $359,549 $21,733 $381,282 2.7 $52,344 Unincorporated area within the PM-10 nonattainment area near Apache Junction 9 3 Supplemental Information Agency Federal Cost Local Cost Total Cost * Daily Emission Reduction (Kilograms /day) Cost- Effectiveness (CMAQ dollar cost per annual metric ton reduced) The requested certified street sweeper will: Have local resources been committed such as staff or equipment to support the operation of the sweeper? Please indicate in what geographical area(s) the requested certified street sweeper will operate Number of certified street sweepers owned and operated by your agency. ** Replace non- certified sweeper Expand Area Swept Increase Sweeping Frequency Replace older certified sweeper Yes No Pinal County #3 $359,549 $21,733 $381,282 2.6 $54,724 Unincorporated area within the PM-10 nonattainment area near Apache Junction 9 Pinal County #1 $359,549 $21,733 $381,282 1.4 $97,981 East Germann Rd. to Bella Vista Rd.; Central Arizona Canal to South Meridian Rd. 9 Total $5,191,762 Applications for all agencies indicate sweeping within four miles of a PM-10 monitor. Application for Phoenix #1 indicates sweeping in Salt River Area. * Total cost for the CMAQ eligible portion of the project; excludes ineligible equipment. ** The total number of certified street sweepers owned and operated by the agency, regardless of funding source. ++ For El Mirage sweeper project, initial funding of $235,108 is available in FY 2025 CMAQ. The remaining $106,865 of the $341,973 requested for the project may become available due to year-end closeout including any additional funding received by the region. +++ On January 22, 2025, the MAG Regional Council approved the FY 2025 Closeout Programming that includes an additional $2,355,757 in FY 2025 CMAQ funding for the remaining balance for the El MIrage sweeper project ($106,865), and the Surprise, Buckeye #1, Chandler, Mesa, Paradise Valley, and Buckeye #2 projects. South Coast Air Quality Management District 21865 Copley Drive, Diamond Bar, CA 91765-4182 (909) 396-2000 www.aqmd.gov CERTIFIED STREET SWEEPERS UNDER South Coast AQMD RULE 1186 (AS OF JULY 10, 2024) South Coast AQMD Rule 1186 requires local governments within the South Coast Air Quality Management District (see Figure below) to procure certified street sweepers for new equipment purchases or new street sweeping contracts made after January 1, 2000 (there are no retrofit requirements under Rule 1186). Various South Coast AQMD regulations also require procurement of certified street sweepers to implement specific rule requirements. This list of equipment is updated periodically based on certifications test results and in response to new information. The South Coast AQMD Governing Board adopted Rule 1186 street sweeper testing and certification procedures in September of 1999. Enclosed is a list of equipment that has met the Rule 1186 certification standards. (The equipment may either be new or upgraded to meet certification specifications). Questions on equipment capabilities and options should be directed to your local distributor and/or the manufacturer. Questions regarding the Rule requirements can be directed to Area Sources, at (909) 396-2390, or areasources@aqmd.gov. * Additional sweepers may be certified based on future tests. You can call 1 (800) CUT-SMOG or visit www.aqmd.gov for the most recent list of Rule 1186 certified equipment. Attachment Two SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 2 MAKE* MODEL* DUST CONTROL SYSTEM* CHALLENGER MANUFACTURING CHALLENGER • THREE (3) 0.03 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • FOUR (4) 0.03 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND THE CONVEYOR • WATER PUMP TO PROVIDE 25 POUNDS PER SQUARE INCH WATER PRESSURE DURING OPERATION; MAXIMUM OF 45 POUNDS PER SQUARE INCH CURBTENDER* (*formerly Wayne Sweepers) CENTURION • SEVEN (7) 0.0925 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR UNDERNEATH THE CAB • TWO (2) 0.0925 INCH DIAMETER ORIFICE NOZZLES PER GUTTER BROOM (GUTTER BROOMS CAN BE OPERATED WITHOUT WATER SPRAYS IF FULLY ENCLOSED SHROUD SYSTEM IS UTILIZED AND MAINTAINED PER THE MANUFACTURERS SPECIFICATIONS) • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR ABOVE CONVEYOR • 300 GALLON WATER TANK • WATER PUMP TO PROVIDE MINIMUM OF SEVEN GALLONS PER MINUTE • SINGLE FAN VACUUM SYSTEM • GLAZED, POLYESTER FILTER SYSTEM (MAINTAINED TO ENSURE PROPER INTEGRITY) SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 3 MAKE* MODEL* DUST CONTROL SYSTEM* CURBTENDER* (*formerly Wayne Sweepers) GLADIATOR • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • SIX (6) 0.0925 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER • FOUR (4) 0.0925 INCH DIAMETER ORIFICE NOZZLES AT THE REAR BROOM • WATER PUMP TO PROVIDE 60 POUNDS PER SQUARE INCH WATER PRESSURE CURBTENDER* (*formerly Wayne Sweepers) WARRIOR • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • SIX (6) 0.0925 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER • WATER PUMP TO PROVIDE 60 POUNDS PER SQUARE INCH WATER PRESSURE ELGIN AIR CUB (LX/DX) CROSSWIND FURY • DIAMOND GRID DUST SEPARATION SCREEN • LOUVERED CENTRIFUGAL DUST SEPARATOR • ONE (1) 0.06 INCH DIAMETER ORIFICE NOZZLE CENTRALLY LOCATED ABOVE FAN INLET IN THE HOPPER • TWO (2) 0.047 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE SUCTION TUBE • FOUR (4) 0.051 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • PUMP TO PROVIDE 40 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 4 MAKE* MODEL* DUST CONTROL SYSTEM* ELGIN CROSSWIND J • DIAMOND GRID DUST SEPARATION SCREEN • S-TRAP CENTRIFUGAL SEPARATOR • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE HOPPER • THREE (3) 0.059 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE SUCTION TUBE • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE ELGIN REGENX RM • DIAMOND GRID DUST SEPARATION SCREEN • S-TRAP CENTRIFUGAL SEPARATOR • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE HOPPER • THREE (3) 0.059 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE SUCTION TUBE • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 5 MAKE* MODEL* DUST CONTROL SYSTEM* ELGIN PELICAN P & S PELICAN S E (WET SUPPRESSION) • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND THE CONVEYOR • TWO (2) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH GUTTER BROOM • WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE ELGIN PELICAN P (WATERLESS SUPPRESSION) • GUTTER/MAIN BROOM FULLY ENCLOSED SHROUD SYSTEM • ONE OR TWO CENTRIFUGAL DUST EVACUATION FAN(S) TO PROVIDE SUBSTANTIALLY SIMILAR AIRFLOW WITHIN A NORMAL OPERATING RANGE • SYNTHETIC MULTI-POCKET FILTER WITH HYDRAULIC SHAKER FOR DUST REMOVAL ELGIN PELICAN P (COMBINATION) • ALL OF THE FEATURES OF THE WET AND WATERLESS SUPPRESSION PELICAN P STREET SWEEPER WITH THE EQUIPMENT OPERATED IN EITHER THE WET OR WATERLESS MODE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 6 MAKE* MODEL* DUST CONTROL SYSTEM* ELGIN EAGLE E EAGLE F EAGLE (CNG) BROOM BEAR ROAD WIZARD • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND THE CONVEYOR • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH GUTTER BROOM • WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE ELGIN EAGLE F (WATERLESS) • GUTTER/MAIN BROOM FULLY ENCLOSED SHROUD SYSTEM • CENTRIFUGAL DUST EVACUATION FAN • SYNTHETIC MULTI-POCKET FILTER WITH HYDRAULIC SHAKER FOR DUST CONTROL ELGIN EAGLE F (COMBINATION) • ALL OF THE FEATURES OF THE WET AND WATERLESS EAGLE F STREET SWEEPER WITH THE EQUIPMENT OPERATED IN EITHER THE WET OR WATERLESS MODE ELGIN BROOM BEAR PLUG-IN HYBRID ELECTRIC • FOUR (4) 0.060 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND THE CONVEYOR • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH GUTTER BROOM • ELECTIC DRIVEN WATER PUMP TO PROVIDE MINIMUM 80 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 7 MAKE* MODEL* DUST CONTROL SYSTEM* ELGIN GEOVAC • DIAMOND GRID DUST SEPARATION SCREEN • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED IN THE HOPPER • TWO (2) 0.059 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE SUCTION TUBE • TWO (2) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES LOCATED AT THE EXTENSION BROOM • WATER PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE ELGIN WHIRLWIND MV • DIAMOND GRID DUST SEPARATION SCREEN • FOUR (4) 0.06 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED IN THE HOPPER • TWO (2) 0.059 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE SUCTION TUBE • TWO (2) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • FOUR (4) 0.60 INCH DIAMETER ORIFICE NOZZLES LOCATED AT THE EXTENSION BROOM • PUMP TO PROVIDE 80 POUNDS PER SQUARE INCH WATER PRESSURE ELGIN BROOM BADGER • MAIN BROOM 58 INCH WIDE AND 35 INCH DIAMETER • FOUR (4) 0.060 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND THE CONVEYOR • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH GUTTER BROOM • ELECTRIC WATER PUMP SYSTEM TO PROVIDE MINIMUM 80 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 8 MAKE* MODEL* DUST CONTROL SYSTEM* GLOBAL ENVIRONMENTAL PRODUCTS M3 R3 R4 M4 M4 HSD M4E Zero Emissions • ENCLOSED ELEVATOR SYSTEM • STEEL OR MIXED POLYESTER MAIN PICK UP BROOM • ONE (1) 0.072 INCH DIAMETER ORIFICE NOZZLE PER EACH GUTTER BROOM • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES PER EACH SIDE OF THE MAIN PICK UP BROOM • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES IN SPRAY BAR LOCATED BEHIND THE MAIN PICK UP BROOM • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN SPRAY BAR LOCATED UNDERNEATH THE CAB • WATER PUMP TO PROVIDE 40 POUNDS PER SQUARE INCH WATER PRESSURE JOHNSTON 310 • FOUR (4) 0.072 INCH DIAMETER ORIFICE NOZZLES LOCATED IN FRONT SPRAY BAR • TWO (2) 0.072 INCH DIAMETER ORIFICE NOZZLES PER EACH GUTTER BROOM • ONE (1) 0.026 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE FAN SUCTION HOOD • WATER PUMP TO PROVIDE 50 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 9 MAKE* MODEL* DUST CONTROL SYSTEM* JOHNSTON 3000 MX450 4000 4000 SDS MST 350 • ENCLOSED ELEVATOR SYSTEM • STEEL OR MIXED POLYESTER MAIN PICK UP BROOM • ONE (1) 0.072 INCH DIAMETER ORIFICE NOZZLE PER EACH GUTTER BROOM • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES PER EACH SIDE OF THE MAIN PICK UP BROOM • THREE (3) 0.057 INCH DIAMETER ORIFICE NOZZLES IN SPRAY BAR LOCATED BEHIND THE MAIN PICK UP BROOM • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN SPRAY BAR LOCATED UNDERNEATH THE CAB • WATER PUMP TO PROVIDE 40 POUNDS PER SQUARE INCH WATER PRESSURE JOHNSTON VT605 VT610 VT650 V501 V651 V801 • TWO (2) 0.039 INCH DIAMETER ORIFICE NOZZLES PER GUTTER BROOM • THREE (3) 0.042 INCH DIAMETER ORIFICE NOZZLES PER SUCTION BROOM • THREE (3) 0.039 INCH DIAMETER ORIFICE NOZZLES PER SUCTION NOZZLE • MULTI-POSITION SUCTION NOZZLE TWO ARM FACILITY • ONE (1) 0.042 INCH DIAMETER ORIFICE NOZZLE FOR THE IMPELLER FAN • WATER PUMP TO PROVIDE 50 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 10 MAKE* MODEL* DUST CONTROL SYSTEM* JOHNSTON 770 CYCLONE/ RT655 • THREE (3) 0.067 INCH DIAMETER ORIFICE NOZZLES FOR GUTTER BROOMS • TWO (2) 0.07 INCH DIAMETER ORIFICE NOZZLES FOR CENTER CURTAIN • FOUR (4) 0.055 INCH DIAMETER ORIFICE NOZZLES FOR FRONT BUMPER • TWO (2) 0.067 INCH DIAMETER ORIFICE NOZZLES FOR FRONT CURB SPRAY • TWO (2) 0.07 INCH DIAMETER ORIFICE NOZZLES ON LEFT AND RIGHT SIDE OF PICK UP HEAD • THREE (3) 0.082 INCH DIAMETER ORIFICE NOZZLES FOR PICK UP HEAD FRONT SIDE • SEVEN (7) 0.079 INCH DIAMETER ORIFICE NOZZLES FOR PICK UP HEAD REAR SIDE • THREE (3) 0.079 INCH DIAMETER ORIFICE NOZZLES FOR WINDROW PATH • TWO (2) 0.045 INCH DIAMETER ORIFICE NOZZLES FOR PICK UP HEAD SUCTION • ONE (1) 0.079 INCH DIAMETER ORIFICE NOZZLE FOR BLOWER FAN OUTLET • PUMP TO PROVIDE 50 POUNDS PER SQUARE INCH WATER PRESSURE NESCON X-BROOM • THREE (3) 0.079 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • FIVE (5) 0.079 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER • FIVE (5) 0.050 INCH DIAMETER ORIFICE NOZZLES IN MAIN BROOM HOUSING • WATER PUMP TO PROVIDE 50 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 11 MAKE* MODEL* DUST CONTROL SYSTEM* NITEHAWK RAPTOR II REGENERATIVE AIR SWEEPER ** ** EQUIPPED WITH PM-10 OPTION PACKAGE • FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN HOPPER • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES ON GUTTER BROOMS • WATER PUMP TO PROVIDE 70 PSI WATER PRESSURE PLEASE NOTE THAT THE PM-10 OPTION PACKAGE DUST CONTROL SYSTEM IS DIFFERENT THAN THE STANDARD MODEL SCHWARZE EV-1 • TWELVE (12) POLYESTER DRY FILTER CARTRIDGES (MAINTAINED TO ENSURE PROPER INTEGRITY) • FILTRATION CLEANED THREE TIMES PER-MINUTE • FILTRATION SYSTEM ACTIVE AT ALL TIMES SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 12 MAKE* MODEL* DUST CONTROL SYSTEM* SCHWARZE EV-2 • EIGHT (8) POLYESTER DRY FILTER CARTRIDGES (MAINTAINED TO ENSURE PROPER INTEGRITY) • FILTRATION SYSTEM OPERATED AT ALL TIMES • EACH FILTER CLEANED THREE TIMES PER MINUTE SCHWARZE DXR • POLYESTER DRY FILTER CARTRIDGES (MAINTAINED TO ENSURE PROPER INTEGRITY) • FILTRATION SYSTEM ACTIVE AT ALL TIMES • FILTRATION CLEANED FOUR TIMES PER MINUTE AND A HALF SCHWARZE A4000/ A4STORM • FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES LOCATED ON THE SWEEPING HEAD • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES INSIDE HOPPER • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM • FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES INSIDE HOPPER ON SPRAY BAR • WATER PUMP TO PROVIDE 70 POUNDS PER SQUARE INCH WATER PRESSURE SCHWARZE M5000/M6000/ M6 AVALANCHE • FIVE (5) 0.036 INCH DIAMETER ORIFICE NOZZLES ON MAIN BROOM • THREE (3) 0.036 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM • WATER PUMP TO PROVIDE 70 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 13 MAKE* MODEL* DUST CONTROL SYSTEM* SCHWARZE A 7000/ A7 TORNADO A7 ZEPHYR A 8000/ A8 TWISTER A 9000/ A9 MONSOON • SAWTOOTH DUST SEPARATION SCREEN, SELF DUMPING DUST SEPARATOR, FAN CENTRIFUGE • FIVE (5) 0.036 INCH DIAMETER ORIFICE NOZZLES LOCATED ON THE SWEEPING HEAD • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES LOCATED ON HEAD INTAKE TUBE • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN RIGHT HAND GUTTER BROOM • FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES LOCATED ON HOPPER SPRAY BAR • WATER PUMP TO PROVIDE 70 POUNDS PER SQUARE INCH WATER PRESSURE • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN LEFT HAND GUTTER BROOM (REQUIRED IF BOTH GUTTER BROOMS ARE USED) SCHWARZE S348-I/ SUPERVAC VORTEX S348-LE/ SUPERVAC GALE FORCE SUPERVAC SUPER UPDRAFT • FOUR (4) 0.036 INCH DIAMETER ORIFICE NOZZLES ON HOPPER SPRAY BAR • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES IN HOPPER • TWO (2) 0.036 INCH DIAMETER ORIFICE NOZZLES ON RIGHT HAND GUTTER BROOM • WATER PUMP TO PROVIDE 70 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 15 MAKE* MODEL* DUST CONTROL SYSTEM* STEWART-AMOS STARFIRE S-4, S-5, AND S-6 • FOUR (4) 0.05 INCH DIAMETER ORIFICE NOZZLES CENTRALLY LOCATED BETWEEN THE MAIN BROOM AND THE ELEVATOR • FOUR (4) 0.05 INCH DIAMETER ORIFICE NOZZLES LOCATED BENEATH THE FRONT BUMPER OF THE CHASSIS • TWO (2) 0.05 INCH DIAMETER ORIFICE NOZZLES LOCATED IN FRONT OF EACH GUTTER BROOM • WATER PUMP TO PROVIDE 40 POUNDS PER SQUARE INCH WATER PRESSURE PYTHON S2000 • FOUR (4) 0.008 INCH DIAMETER ORIFICE NOZZLES MOUNTED ABOVE AND AHEAD OF A 36 INCH FILL DIAMETER REAR BROOM • WATER LINE WITH 0.02 INCH DIAMETER ORIFICE AND THREE (3) 0.06 DIAMETER OUTLETS ABOVE EACH 42 INCH DIAMETER GUTTER BROOM • PUMP TO PROVIDE 24 POUNDS PER SQUARE INCH WATER PRESSURE DURING OPERATION PLEASE NOTE THAT THE GUTTER AND REAR BROOM SIZES ARE DIFFERENT THAN THE STANDARD MODEL PYTHON S3000 • FOUR (4) 0.008 INCH DIAMETER ORIFICE NOZZLES MOUNTED ABOVE AND AHEAD OF REAR BROOM • WATER LINE WITH 0.02 INCH DIAMETER ORIFICE AND THREE (3) 0.06 DIAMETER OUTLETS ABOVE EACH GUTTER BROOM • PUMP TO PROVIDE 24 POUNDS PER SQUARE INCH WATER PRESSURE DURING OPERATION SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 15 MAKE* MODEL* DUST CONTROL SYSTEM* TENNANT SENTINEL • GUTTER/MAIN BROOM FULLY ENCLOSED SHROUD SYSTEM • DUAL FAN VACUUM SYSTEM (OPERATED AT ALL TIMES) • SYNTHETIC-SINGED POLYESTER FILTER (MAINTAINED TO ENSURE PROPER INTEGRITY) TENNANT 830 / 831 II • GUTTER/MAIN BROOM FULLY ENCLOSED SHROUD SYSTEM • DUAL FAN VACUUM SYSTEM (OPERATED AT ALL TIMES) • SYNTHETIC-SINGED POLYESTER FILTER (MAINTAINED TO ENSURE PROPER INTEGRITY) TYMCO 210 300 350 435 • CYCLONIC, MULTIPASS, CENTRIFUGAL SEPARATION • CENTER DEBRIS DEFLECTOR ASSEMBLY PERPENDICULAR TO THE PICK UP HEAD • TWO (2) 0.043 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLE FOR EACH GUTTER BROOM • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE HOPPER • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLE LOCATED IN BLOWER HOUSING • WATER PUMP WITH A MINIMUM SYSTEM RELIEF VALVE SET AT 25 POUNDS PER SQUARE INCH SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 15 MAKE* MODEL* DUST CONTROL SYSTEM* TYMCO 600 600 BAH FHD 500X • CYCLONIC, MULTIPASS, CENTRIFUGAL SEPARATION • CENTER DEBRIS DEFLECTOR ASSEMBLY PERPENDICULAR TO THE PICK UP HEAD • FRONT DEBRIS DEFLECTOR CURTAIN ASSEMBLY PARALLEL TO THE PICK UP HEAD • LOW EMISSION DUST GUARDS (ONLY APPLICABLE TO CABOVER TRUCKS) • THREE (3) 0.063 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM • TWO (2) 0.043 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM • ONE (1) 0.093 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE HOPPER • ONE (1) 0.093 INCH DIAMETER ORIFICE NOZZLE LOCATED IN BLOWER HOUSING • TWO (2) [MINIMUM] HOPPER BAFFLE CURTAINS • WATER PUMP WITH A MINIMUM SYSTEM RELIEF VALVE SET AT 25 POUNDS PER SQUARE INCH TYMCO DST - 4 • CYCLONIC, MULTIPASS, CENTRIFUGAL SEPARATION • SELF CONTAINED MULTIPLE FILTRATION SYSTEM UTILIZING PTFE MEMBRANE FILTERS • TWO (2) 0.043 INCH DIAMETER ORIFICE NOZZLES FOR EACH 32 INCH DIAMETER GUTTER BROOM • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLES FOR EACH 32 INCH DIAMETER GUTTER BROOM • ONE (1) 0.063 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE HOPPER • WATER PUMP WITH A MINIMUM SYSTEM RELIEF VALVE SET AT 25 POUNDS PER SQUARE INCH SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 15 MAKE* MODEL* DUST CONTROL SYSTEM* TYMCO DST - 6 • CYCLONIC, MULTIPASS, CENTRIFUGAL SEPARATION • SELF CONTAINED MULTIPLE FILTRATION SYSTEM UTILIZING PTFE MEMBRANE FILTERS • THREE (3) 0.063 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM • TWO (2) 0.043 INCH DIAMETER ORIFICE NOZZLES FOR EACH GUTTER BROOM • ONE (1) 0.094 INCH DIAMETER ORIFICE NOZZLE LOCATED IN THE HOPPER • TWO (2) [MINIMUM] HOPPER BAFFLE CURTAINS • WATER PUMP WITH A MINIMUM SYSTEM RELIEF VALVE SET AT 25 POUNDS PER SQUARE INCH VACALL VS10/10D, VF10 VS13/13D, VF13 VS14/14D, VF14 VS16/16D, VF16 VS20/20D, VF20 • FOUR (4) 0.062 INCH DIAMETER ORIFICE NOZZLES LOCATED IN FRONT OF EACH 36 INCH GUTTER BROOM • FOUR (4) 0.062 INCH DIAMETER ORIFICE NOZZLES LOCATED IN FRONT OF THE TRANSFER BROOM • TEN (10) 0.125 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE PICK UP HEAD • SIX (6) 0.181 INCH DIAMETER ORIFICE NOZZLES LOCATED INSIDE THE SCRUBBER COLLAR OF THE PICK UP HEAD • 48 INCH POWER VACUUM NOZZLE • MINIMUM 300 GALLON GRAVITY FEED WATER SUPPLY SYSTEM WITH WATER CONTINUOUSLY SUPPLIED TO ALL NOZZLES • LOW VELOCITY DUST COLLECTION AIR CHAMBER • MINIMUM OF SIX (6) EXPANDED METAL SCREENS SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 15 MAKE* MODEL* DUST CONTROL SYSTEM* WAYNE SWEEPERS* (*acquired by Curbtender) CENTURION • SEVEN (7) 0.0925 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR UNDERNEATH THE CAB • TWO (2) 0.0925 INCH DIAMETER ORIFICE NOZZLES PER GUTTER BROOM • (GUTTER BROOMS CAN BE OPERATED WITHOUT WATER SPRAYS IF FULLY ENCLOSED SHROUD SYSTEM IS UTILIZED AND MAINTAINED PER THE MANUFACTURERS SPECIFICATIONS) • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES ON SPRAY BAR ABOVE CONVEYOR • 300 GALLON WATER TANK • WATER PUMP TO PROVIDE MINIMUM OF SEVEN GALLONS PER MINUTE • SINGLE FAN VACUUM SYSTEM WAYNE SWEEPERS (*acquired by Curbtender) GLADIATOR • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • SIX (6) 0.0925 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER • FOUR (4) 0.0925 INCH DIAMETER ORIFICE NOZZLES AT THE REAR BROOM • WATER PUMP TO PROVIDE 60 POUNDS PER SQUARE INCH WATER PRESSURE WAYNE SWEEPERS (*acquired by Curbtender) WARRIOR • THREE (3) 0.0925 INCH DIAMETER ORIFICE NOZZLES LOCATED AT EACH SIDE BROOM • SIX (6) 0.0925 INCH DIAMETER ORIFICE NOZZLES ACROSS FRONT BUMPER • WATER PUMP TO PROVIDE 60 POUNDS PER SQUARE INCH WATER PRESSURE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (South Coast AQMD) RULE 1186 CERTIFIED* STREET SWEEPERS AS OF JULY 10, 2024 THE FOLLOWING IS A LIST OF STREET SWEEPING EQUIPMENT THAT HAS CURRENTLY BEEN CERTIFIED FOR South Coast AQMD RULE 1186. ALL CERTIFIED EQUIPMENT MUST BE OPERATED AND MAINTAINED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. FUTURE TESTING MAY QUALIFY ADDITIONAL EQUIPMENT. CALL 1 (800) CUT-SMOG FOR THE CURRENT LIST * In order to ensure compliance with Rule 1186 requirements, all certified equipment must be operated and maintained in accordance with the manufacturer's specifications. End users are responsible for ensuring that the dust control systems are in place for each certified sweeper. Note: The make and model of the sweeper must have the dust control system(s) specified above to be in compliance. (Standard or older models may not have all the systems). Please contact the manufacturer if you would like to ensure that your sweeper(s) are Rule 1186 compliant. 15 ADDITIONAL NOTES: ** For any entity wishing to operate a NiteHawk Raptor II compliant with Rule 1186, the sweeper must be ordered with PM-10 Option Package, which includes the following: - Front Spray bar configured with Four (4) 0.036-inch Orifice Spray Nozzles - Two (2) Sweeper Head Spray Nozzles Removed from the Dust Suppression System - 24” Whisper Wheel Fan Turbine Installed in place of Standard Hi Flow Fan Turbine - Low Profile Brooms installed (applicable to driver side and passenger side brooms) o 60 holes, 17 bristles. Bristle Dimension: 20” Length, 0.034” Thick, 0.011” Width - Blower Vacuum System o System will be tuned to an airflow rating of 6,178 CFM o System will be tuned to deliver 27 HP at fan May 19, 2017 EXAMPLES OF ADDITIONAL STREET SWEEPER EQUIPMENT NOT ELIGIBLE FOR REIMBURSEMENT 1. Automatic lubrication system (Autolube, grease jockey system) 2. Hopper access step 3. Hydrant hopper wash down system 4. Conveyer flush kit with hydrant 5. 1000 pounds per square inch (PSI) wand 6. Dual HiBack air-suspended seats 7. Hand hose 8. Hopper sound suppression 9. Right hand steer chassis upcharge 10. Air horn (reimbursable when conventional electric horn is not included) 11. AM/FM radio; CD 12. Training 13. Magnet bar 14. Stainless steel hopper 15. Sweeper, truck and wheel yellow paint 16. Additional roof-mounted air conditioner 17. Holder rear mount for five-gallon pail 18. Cigarette lighter with 12v 19. Foam filled tire 20. Window tinting 21. Move exhaust port to left side of vehicle 22. John Deere auxiliary engine - Tier iT4 Attachment Three ARIZONA DEPARTMENT OF TRANSPORTATION 1801 W. Jefferson St., Suite 120, MD 102M | Phoenix, AZ 85007 | azdot.gov Infrastructure Delivery and Operations MEMORANDUM TO: PM 10 Street Sweepers Program Awardees FROM: Lisa Pounds, Local Public Agency Manager CC: Patrick Stone, Federal Aid Administrator DATE: Tuesday June 11, 2019 RE: Interim Process for Disposition of Street Sweepers acquired with federal funds under FIN- 11.08 Federal Property Management Standards Policy This memorandum serves as notice to recipients and subrecipients of federal funds through a pass-through entity that acquire, in whole or in part, with federal funds or whose costs are charged to a project supported by a federal grant, of a change in procedure for the disposition of street sweepers owned by subrecipients. Due to administrative changes in the PM 10 Street Sweeper Program, ADOT Policy FIN-11.08 Federal Property Management Standards (attached) is in the process of being updated. In the interim, ADOT is requesting that subrecipients no longer forward funds resulting from the trade-in or sale without replacement of sweepers to the entity from which it received funds for the original purchase. Instead, the funds will need to be forwarded to ADOT. ADOT’s Financial Management Services division will make adjustments to the current or future year distribution from the federal awarding agency. Should you have any questions regarding this change in procedure, you may contact me at LPounds@azdot.gov or 602-712-8088. Sincerely, Lisa Pounds Local Public Agency Manager Attachment Four