Zoning Application

City of El Mirage — Regular Meeting (2025-07-01)

View PDF Item 3 Meeting page

Extracted text (via pymupdf) 17792 characters
Source: Maricopa County CIO, Maricopa County Assessor’s Office 
PROJECT NARRATIVE
DEVELOPMENT OF TWO NEW DUPLEX BUILDINGS ON A VACANT LOT
1. Project Title:
Pulido Two-New Duplex Residential Buildings
2. Project information:
Owner:
Pulido Jose S Mendez
Phone:
------
Address:
------
Representative Name: Angelica Armenta
Business Name:
ProCa Design LLC
Address: 
1301 E Washington St. Suite 202, Phoenix, AZ 85034
Phone:
602-606-2885
Email:
angelica@procadesign.com
3. Property information:
Project Address:
13225 N Main St El Mirage 85335
Subdivision:
N/A
Jurisdiction:
El Mirage
Section T.R.:
13 3N 1W
Lot:
N/A
Parcel #:
501-32-015C
Zoning: 
MU
Net Size Acreage:
31,799 SF = 0.73 ACRES
Aerial View of Property:

4. Project Summary:
Location:
13225 N Main St El Mirage 85335
Summary:
The proposed development is located on a 31,799-square-foot interior lot with frontage along N Main 
Street. The site is zoned MU (Mixed Urban) and designated as Mixed Urban Zone under the City’s 
General Plan. The project consists of two new duplex residential buildings, for a total of four suites. The 
project is seeking approval of a Conditional Use Permit and Site Plan.
Land use Designation & Applicable Plans/Guidelines
Zoning designation: MU
Comp. Plan Designation: Mixed Urban Zone
Project Description.
The Project Site consists of approximately 31,799 square feet and its currently vacant. The proposal 
includes the construction of two new duplex buildings totaling of 7,406 square feet, including an area for
a trash enclosure. The buildings will collectively offer four residential suites. Each suite has an  area of 
1,819 square feet (including both livable and non-livable space). 
The design features a stucco sand finish, treated exposed wood elements, and decorative exterior wall 
tile, aligning with the architectural character of the surrounding neighborhood. The site is a rectangular 
shaped lot with frontage on N Main St.
Parking:
On-site parking is provided via four two-car garages, one per suite, meeting the City’s parking 
requirements by offering two assigned spaces per unit. Vehicle access to the site is from N Main Street.
Trash Facilities:
The trash enclosure is located at the middle of the west frontage of the site, with accessible entry from 
the new on-site driveway. 
Landscaping:
The project includes new landscaping throughout the driveway and buildings, as well as the planting of 
trees, shrubs, and accent plants to enhance the site aesthetics and contribute to the urban 
environment.
Analysis
Neighborhood Setting and character
The project site is an interior lot on N Main St between W Myer Ln and W Valentine St. There are 
residential developments located across de street. And vacant lots adjacent to all the other sides of the 
lot. Land uses on the surroundings are Mixed Urban Zone and Suburban Neighborhood Zone.
Within the vicinity of the site, buildings are generally low, one to two-story buildings. The project 
proposes development that is consistent with the zoning code development standards.

Site Analysis Photos

Image 1
Image 2

Image 3
Image 4

Image 5
Image 6

Image 7
Image 8

SHEET:
SCALE:
DRAWN BY:
DATE:
#
REVISIONS
DATE
CONTACT #
5/1/2025
THE INFORMATION CONTAINED ON THESE DRAWINGS SUCH AS
DATA, DESIGNS, AND CONCEPTS, ARE PROPERTY OF PROCADESIGN
LLC.  AND SHALL NOT BE USED  FOR ANY   OTHER PURPOSE OTHER
THAN ORIGINALLY INTENDED WITHOUT WRITTEN PERMISSION OF
THE DESIGNER/CONSULTANT .
www.procadesign.net
(602) 606-2885
info@procadesign.com
PULIDO PROJECT / TWO NEW DUPLEX
13225 N MAIN ST. UNITS 101,102,103 & 104
EL MIRAGE 85335
PROCA DESIGN LLC
PER PLAN
NOTE: SITE PLAN DIMENSIONS ARE OBTAINED FROM COUNTY ASSESSOR'S WEBSITE AND ARE
TO BE USED AS A POINT OF REFERENCE ONLY. FOR EXACT DIMENSIONS, PLEASE CONTACT A
REGISTERED SURVEYOR.  PROCADESIGN SHOULD NOT BE HELD LIABLE IF THE DIMENSIONS
FOUND ON COUNTY ASSESSOR'S WEBSITE ARE INACCURATE, IT IS THE RESPONSIBILITY OF THE
OWNER/CONTRACTOR TO GET A SURVEY OF THE PROPERTY.
PROPERTY LINE.
CENTRAL LINE
SET BACK LINE.
OVERHANG
WATER LINE
SEWER LINE
WL
SL
EXISTING SIDEWALK
RIGHT OF WAY
PUBLIC UTILITY EASEMENT
BUILDING SETBACK LINE
FINISH FLOOR ELEVATION
WM
OVERHANG ELECTRIC
OHE
WATER METER
UNDERGROUND ELECTRIC
UGE
GAS LINE
G
FIBER CABLE
F0
SGV
PL
CHAIN LINK FENCE
BLOCK WALL
COP BRASS CAP
PROPERTY CORNER
ASSESSOR PARCEL NUMBER
MARICOPA COUNTY RECORDS
CITY OF PHOENIX
BACK OF SIDEWALK
BACK OF CURB
LIP OF GUTTER
GAS VALVE
SANITARY SEWER MANHOLE
A0
PROJECT LOCATION
NORTH
VICINITY MAP
NOT TO SCALE
SITE PLAN NOTE
LEGEND
(NOT ALL USED)
LIVABLE AREA
4768
  SQ. FT.
FRONT PORCH (NOT LIVABLE)
316
  SQ. FT.
COVERED PATIO (NOT LIVABLE)
444
  SQ. FT.
GARAGE (NOT LIVABLE)
1,748
  SQ. FT.
LIVABLE
4768
  SQ. FT.
NON LIVABLE
2,508
  SQ. FT.
TRASH ENCLOSURE
130
  SQ. FT.
TOTAL FOOT PRINT(LIVABLE+ NOT LIVABLE)
7,406
  SQ. FT.
LOT SIZE
31,799  SQ. FT.
LOT COVERAGE
23.29
%
MAX LOT COVERAGE
90.00
%
SCALE: 1' = 20'-0"
13225 N MAIN ST EL MIRAGE 85335
EL MIRAGE
13 3N 1W
N/A
501-32-015C
N/A
MIXED URBAN (MU)
VACANT
DWELLING, MULTI-FAMILY
PROJECT INFORMATION
OWNER
PROJECT DESCRIPTION
PROJECT ADDRESS:
JURISDICTION:
SECTION T.R.:
LOT.:
PARCEL #:
CONSTRUCTION YEAR:
ZONING:
CURRENT LAND USE:
PROPOSED LAND USE:
PULIDO JOSE S MENDEZ
TWO NEW DUPLEX
DEVELOPER:
NAME:PROCADESIGN LLC
PHONE NUMBER:602-606-2885
EMAIL ADDRESS:INFO@PROCADESIGN.COM
ADDRESS:3104 E WASHINGTON ST, SUITE 2, PHOENIX AZ 85034
KEYNOTES:
VICINITY MAP
TOTAL OF AREAS (BOTH DUPLEX)
TOTAL AREAS:
NOTES:
LANDSCAPE AREA
DRIVEWAY 
CONCRETE
AREA PER UNIT
LIVABLE AREA
1192
  SQ. FT.
FRONT PORCH (NOT LIVABLE)
79
  SQ. FT.
COVERED PATIO (NOT LIVABLE)
111
  SQ. FT.
GARAGE (NOT LIVABLE)
437
  SQ. FT.
COEM- EM-113-1 - TRASH ENCLOSURE
1.
DRIVEWAY SHALL BE DESIGNED TO HANDLE 75,000 LBS
2.
ANY CHANGE OF USE OR OCCUPANCY OF ANY
BUILDING OR BUILDINGS, INCLUDING ADDITIONS
THERETO REQUIRING MORE PARKING, SHALL NOT BE
PERMITTED UNTIL SUCH ADDITIONAL PARKING SPACES
AS REQUIRED BY THIS CHAPTER ARE FURNISHED.
3.
DRIVEWAY MUST BE AN APPROVED ALL WEATHER
ROADWAY.
4.
BUILDING STRUCTURE TO BE DESIGNED AS
TOWNHOMES PER INTERNATIONAL RESIDENTIAL CODE.
NOTE:  ANY CHANGE OF USE OR OCCUPANCY OF ANY BUILDING OR BUILDINGS, INCLUDING
ADDITIONS THERETO REQUIRING MORE PARKING, SHALL NOT BE PERMITTED UNTIL SUCH
ADDITIONAL PARKING SPACES AS REQUIRED BY THIS CHAPTER ARE FURNISHED
DESCRIPTION
AREA (SQ FT)
NOTES
EXISTING LOT AREA
31799
FULL LOT SIZE BEFORE
ROW DEDICATION
PROPOSED ROW DEDICATION
1635
 ROW AREA = 16 FT ×
102.22 FT
PROPOSED NET LOT AREA
30,164
  31,799 SQ FT -
1,635.52 SQ FT
BUILDING FOOTPRINT (TOTAL)
7,406
COMBINED
FOOTPRINT OF ALL
UNITS & TRASH
ENCLOSURE
LOT COVERAGE(90%)
23.29 %
WELL BELOW THE
90% MAX -
✔COMPLIANT
TOTAL LOT AREAS
1.
DEVELOPMENT PROPERTY LINE
2.
SETBACK LINE
3.
SIGHT VISIBILITY TRIANGLE, PER DETAIL COEM EM-158 SHALL BE
KEPT CLEAR OF VEGETATION THAT AT MATURITY WILL HAVE
HEIGHTS GREATER THAN 30" AND TREES THAT HAVE BRANCHES
LOWER THAN 84"; AS MEASURED FROM PAVEMENT SURFACE.
4.
TRASH ENCLOSURE PER DETAIL COEM EM-113-1, EM-113-2
5.
EXISTING FIRE HYDRANT
6.
EXISTING POWER POLE (W MINIMUM 72-INCH X 72-INCH CLEAR
WORKING SPACE)
7.
EXISTING POWER POLE WITH LIGHT
8.
CONCRETE PAVED DRIVEWAY
9.
NEW BUILDING ENTRANCE
10. NEW BUILDING SUBJECT OF THIS PROJECT *-16' TOP OF ROOF
11.
COMMON AREAS
12.
STOP SIGN
13. FIRE LANE
14.
6 3
4" FIRE RATED WALL PER UL-U305
15. P.U.E. LINE
16. DEDICATED RIGHT OF WAY LINE NEXT TO PROPERTY
17.
VERTICAL CURB AND GUTTER
18. ROW LANDSCAPE STRIP
19.
OM4-2 (18"X18") SIGN
20. EXISTING PALM TREE
21. ACCEPTABLE ALTERNATE TO 120' HAMMERHEAD PER COEM-EM-114
22. SIDEWALK RAMP
23. 6' HEIGHT CMU WALL TO ENCLOSE PRIVATE PATIOS
24. WOOD FENCE FOR DESIGN ONLY

SHEET:
SCALE:
DRAWN BY:
DATE:
#
REVISIONS
DATE
CONTACT #
5/1/2025
THE INFORMATION CONTAINED ON THESE DRAWINGS SUCH AS
DATA, DESIGNS, AND CONCEPTS, ARE PROPERTY OF PROCADESIGN
LLC.  AND SHALL NOT BE USED  FOR ANY   OTHER PURPOSE OTHER
THAN ORIGINALLY INTENDED WITHOUT WRITTEN PERMISSION OF
THE DESIGNER/CONSULTANT .
www.procadesign.net
(602) 606-2885
info@procadesign.com
PULIDO PROJECT / TWO NEW DUPLEX
13225 N MAIN ST. UNITS 101,102,103 Θ 10ϰ
EL MIRAGE 85335
PROCA DESIGN LLC
PER PLAN
A0.1
PROJECT LOCATION
NORTH
VICINITY MAP
NOT TO SCALE
VICINITY MAP
CONTEXT  PLAN
SCALE: 1" = 30'-0"
NORTH

PANTRY
LAUNDRY
M.W.I.C.
KITCHEN
BATH
PORCH
COV.PATIO
BEDROOM 2
BEDROOM 1
M.BATH
LIVING
2-GARAGE
PANTRY
M.W.I.C.
KITCHEN
BATH
PORCH
COV.PATIO
BEDROOM 2
BEDROOM 1
M.BEDROOM
M.BATH
LIVING
2-GARAGE
M.BEDROOM
LAUNDRY
-
2x6 WOOD STUDS  @ 16"O.C.
-
1/2" RESILIENT CHANNEL, 25ga. @24 O.C.
-
6-1/4" FIBERGLASS INSULATION
-
5/8" X GYPSUM PANELS
1HR FIRE RATED
WALL
UL-U305
KEYNOTES
1.
2X WOOD STUD
FRAMING WALL.
2.
6 1/4" FIBERGLASS
INSULATION
3.
5/8" X GYPSUM
PANELS
4.
1/2" RESILIENT
CHANNEL 25ga.
SHEET:
SCALE:
DRAWN BY:
DATE:
#
REVISIONS
DATE
CONTACT #
5/1/2025
THE INFORMATION CONTAINED ON THESE DRAWINGS SUCH AS
DATA, DESIGNS, AND CONCEPTS, ARE PROPERTY OF PROCADESIGN
LLC.  AND SHALL NOT BE USED  FOR ANY   OTHER PURPOSE OTHER
THAN ORIGINALLY INTENDED WITHOUT WRITTEN PERMISSION OF
THE DESIGNER/CONSULTANT .
www.procadesign.net
(602) 606-2885
info@procadesign.com
PULIDO PROJECT / TWO NEW DUPLEX
13225 N MAIN ST. UNITS 101,102,103 Θ 10ϰ
EL MIRAGE 85335
PROCA DESIGN LLC
PER PLAN
A1
LEGEND:
1-HR FIRE RATED WALL PER UL U305
FRAMING  WALLS
ENVELOPED AREAS SHALL COMPLY WITH THE FOLLOWINGS: FENCES=0.40 MAX U-FACTOR,0.25
MAX SHGC. MIN R-13 AT FRAME WALLS AND FLOORS R-6 @ MASS WALL, R-38 CEILINGS. DUCT
INSULATION LOCATED OUTSIDE THE BUILDING ENVELOPE REQUIRES MINIMUM R-8 AND R-6
WHEN LOCATED IN FLOOR JOISTS. MINIMIZE AIR LEAKAGE.
ENERGY EFFICIENCY:
2X6 @ 16" O.C. EXTERIOR WALLS
2X4 @ 16" O.C. INTERIOR BEARING WALLS
2X4 @ 24" O.C. INTERIOR NON-BEARING WALLS
2X6 @ 24" O.C. INTERIOR PLUMBING WALLS
2X6 @ 16" O.C. EXTERIOR PLUMBING WALLS
NOTES FOR STUDS & WALLS
AREAS PER UNIT
LIVABLE
1,192
  SQ. FT.
FRONT PORCH (NON LIVABLE)
79
  SQ. FT.
GARAGE (NON LIVABLE)
437
  SQ. FT.
COVERED PATIO (NON LIVABLE)
111
  SQ. FT.
TOTAL
1,819
  SQ. FT.
SCALE: 1/4" = 1'-0"
AESTHETIC VOLUME
PLANTER
ROOF LINE

TOP OF AESTHETIC VOLUME
 TOP OF PARAPET
TOP OF PARAPET 
TOP OF ROOF 
WINDOW AND DOOR HEADER
GARAGE DOOR HEADER
TOP OF PLANTERS
ABOVE FINISH FLOOR
 TOP OF AESTHETIC VOLUME
 TOP OF PARAPET
TOP OF PARAPET 
TOP OF ROOF 
WINDOW AND DOOR HEADER
TOP OF PLANTERS
ABOVE FINISH FLOOR
 TOP OF AESTHETIC VOLUME
 TOP OF PARAPET
TOP OF ROOF 
TOP OF PLANTERS
ABOVE FINISH FLOOR
SLOPE 12:1/4
 TOP OF AESTHETIC VOLUME
 TOP OF PARAPET
TOP OF ROOF 
TOP OF PLANTERS
ABOVE FINISH FLOOR
SLOPE 12:1/4
SHEET:
SCALE:
DRAWN BY:
DATE:
#
REVISIONS
DATE
CONTACT #
5/1/2025
THE INFORMATION CONTAINED ON THESE DRAWINGS SUCH AS
DATA, DESIGNS, AND CONCEPTS, ARE PROPERTY OF PROCADESIGN
LLC.  AND SHALL NOT BE USED  FOR ANY   OTHER PURPOSE OTHER
THAN ORIGINALLY INTENDED WITHOUT WRITTEN PERMISSION OF
THE DESIGNER/CONSULTANT .
www.procadesign.net
(602) 606-2885
info@procadesign.com
PULIDO PROJECT / TWO NEW DUPLEX
13225 N MAIN ST. UNITS 101,102,103 Θ 104
EL MIRAGE 85335
PROCA DESIGN LLC
PER PLAN
A2
A.
ONE(1) COAT STUCCO SYSTEM (ESR-2323) OVER 1" GA SELF-FURRED WOVEN WIRE FABRIC
OVER 1" SUBSTRATE (AS LISTED BELOW) OVER 1-GRADE "D" BUILDING PAPER(U.N.O)
SUBSTRATE:
1)
FROM TOP OF SLAB TO ROOF PLATE LINE 1" EXPANDED POLYSTYRENE
2)
ABOVE TOP PLATE:1" INSULATIONS FOAM BOARD,EXCEPTIONS:AT OPTIONAL
CATHEDRAL INSULATION,1" EXPANDED    POLYSTYRENE SHALL BE USED AT ALL
CONDITIONED AREAS BELOW AND ABOVE TOP PLATE.
B.
MAG ONE-COAT STUCCO COMPLIANCE PROGRAM, ALL ONE-COAT STUCCO SYSTEMS SHALL
BE 
APPLIED 
BY 
MANUFACTURERS 
APPROVED 
INSTALLERS. 
AN 
APPROVED
WEATHER-RESISTIVE BARRIER SHALL BE INSTALLED OVER ALL FRAMING AND WOOD BASED
SHEATHING.
C.
PROVIDE (2) LAYER 30# FELT FLASHING AT ALL HEADS, JAMBS, AND SILLS OF WINDOWS
AND DOOR OPENINGS. REFER TO TYPICAL DETAIL OF WINDOW FLASHING
D.
PROVIDE CONTINUOUS SEALANT BEAD WHERE STUCCO ABUTS WINDOWS AND DOORS
FRAME SO AS TO PROVIDE A WEATHER RESISTIVE BARRIER.REFER TO TYPICAL DETAIL OF
WINDOW FLASHING.
E.
PROVIDE CONT. 26 GA. G.I. WEEP SCREED, WITH 3-1/2" VERTICAL NAILING FLANGE AT +4"
ABOVE FINISH GRADE.
F.
MECHANICAL EQUIPMENT TO BE SCREENED BY WALL +1'-0" ABOVE HIGHEST MECHANICAL
EQUIPMENT.
G.
FLAT ROOF SYSTEM PER CONTRACTOR
STUCCO SYSTEM PER ESR-2323
EXPOSED TREATED  WOOD
BRICK VENEER PER ESR-2598 (SOLSTICE STONE)
EXTERIOR WALL TILE 
FLAT ROOF SYSTEM PER CONTRACTOR 
ELEVATION GENERAL NOTES
LEGEND
SCALE: 1/8" = 1'-0"
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
STUCCO SYSTEM PER ESR-2323

Existing Tree to remain
ACCENTS
GROUND
COVER
SHRUBS
TREES
SYMBOL
NAME
SIZE
QTY.
LANDSCAPE LEGEND
-
-
24" Box
8
24" Box
5
5 Gal.
3
3 Gal.
24
Caesalpinia cacalaco
CASCALOTE
Quercus virginiana x fusiformis 'JOAN LIONETTI'
JOAN LIONETTI TEXAS LIVE OAK
Hardenbergia violacea
AUSTRALIAN LILAC
Tetraneuris acaulis
ANGELITA DAISY
MATERIAL
1
2" Screened
Decomposed Granite
Mountain Vista Brown
2" Depth in All Planting Spaces
Existing Palm to be Removed
-
2
Eremophila maculata
RED EMU BUSH
Leucophyllum frutescens 'Green Cloud'
TEXAS SAGE
Sphaeralcea ambigua
ORANGE GLOBEMALLOW
Fouquieria splendens
OCOTILLO
5 Gal.
28
5 Gal.
30
5 Gal.
38
36" Box
1
5 Gal.
68
Lantana x 'New Gold'
NEW GOLD LANTANA
15 Gal.
4
Dasylirion quadrangulatum 
MEXICAN GRASS TREE
24" Box
6
Ulmus parvifolius
EVERGREEN ELM
5 Gal.
19
Teucrium chamaedrys 'Prostratum'
PROSTRATE GERMANDER
5 Gal.
29
Hesperaloe parviflora 'PERPA'
BRAKELIGHTS YUCCA
24" Box
8
Sophora secundiflora
TEXAS MOUNTAIN LAUREL
Revisions
OF
Date: 
US-60
MAIN ST
N
Key Map
1
Urban
Design
Phone: 480-893-3849  Fax:  480-893-3846
8611 S. Priest Drive, Suite 101 Tempe, AZ 85284
Email: janet@waibel-la.com
Website: www.waibel-la.com
Master
Planning
Consulting
Gardens &
aibel & Associates
andscape  Architecture
WL
SHEET
NUMBER
NAME OF
PROJECT
For:
OWNER/CLIENT
13225 N MAIN ST
EL MIRAGE, AZ, 85335
EMAIL/PHONE/FAX
Call at least two full working days
before you begin excavation
Dial 8-1-1 or 1-800-STAKE-IT (782-5348) In
Maricopa County: (602) 263-1100
Arizona Blue Stake, Inc.
4/30/2025
RIVER RD
VALENTINE ST
MEYER LN
SITE
1
PRELIMINARY
LANDSCAPE
PLAN
North
20'
0'
20'
40'
1"= 20'-0"
4/30/2025
N MAIN ST
⅊
⅊
⅊
⅊
⅊
⅊
NEW DRIVEWAY
1.
Landscape areas are defined as all non paved areas disturbed by construction. Slight
variations may exist between actual site conditions and drawings. Contractor shall adjust
planting layout as required to maintain plant quantities and design intent.  For areas over
100 s.f. contact landscape architect for revision to plant layout.
2.
The contractor shall not substitute any plant (in species, variety, or patent) for any plant
that is specified in the legend. If availability is a problem, the contractor shall contact the
Owner and the landscape architect to discuss acceptable options.
3.
Coordinate all necessary excavation areas with owner's representative.
4.
Landscape contractor is responsible for all landscape sleeving. Coordinate installation with
general contractor.  Verify any existing sleeves installed by other contractors.
5.
Irrigation and electrical sleeves to be Schedule 40 PVC. All sleeves to extend 6" beyond
concrete structures and curbs. Allow at least 4" - 6" from end of sleeves to first fitting on
irrigation lines.  All sleeves to be 24" below grade and/or as per project details.
6.
Common sleeves may be used for lateral lines and mainlines. Contractor is responsible for
adequate size sleeve so all pipes move freely within the sleeve. Contractor to 'As Built' all
sleeve sizes and locations.
7.
Mark back of curbs at sleeve locations by notching the concrete with 1
2"  "V" notch.
8.
Finished grade(s) noted on the landscape plan to be field verified/approved and modified
as per architectural civil drawings.
9.
Granular top dressing shall extend under shrubs and be raked uniformly along curbs,
sidewalks and walls at a consistent depth as specified.
10. Landscape contractor to contact the owner's representative before each application of
pre-emergent for verification. Minimum 2 applications are required, one just before
spreading d.g. and one after D.G. has been fine raked and leveled. Applications shall be
thoroughly watered in and prior to applying D.G.
11. Retention basins shall be constructed solely from the approved civil plans. Any alteration
of the approved design (additional fill, boulders, etc.) shall require additional final plans,
staff review and approval.
12. Refer to specifications for additional requirements not shown on drawings.
13. The Landscape Contractor shall be responsible for the proper care and handling of trees
and plants for delivery and placement in planting pit. Trees that are dropped from trucks or
dropped into pits shall be rejected for replacement by the landscape contractor. If rootballs
fall apart during the planting operation the plant shall not be planted.  New plant materials
shall be provided to replace those that rootballs fall apart.
14. Plant containers shall be cut to remove rootballs that are tight in the container. The
contractor shall not remove the plant from the container by the trunk. Rootbound plants
and trees shall not be planted unless proper modifications can be made to the rootball.
15. The Landscape Contractor shall warrant the trees and shrubs for one year from the date
they are planted.
LANDSCAPE NOTES (NOT APPROVED BY CITY OF EL MIRAGE):
BUILDING
SIGHT
VISIBILITY
TRIANGLE
DEVELOPMENT SUMMARY:
Gross Lot Size: 31,799 sq. ft. (0.73 ac.)
APN #501-32-015C
Section, Township, Range: 13, 3N, 1W
LANDSCAPE ARCHITECT:
Waibel & Associates
Landscape Architecture, LLC
Janet L. Waibel R.L.A.
8611 South Priest Drive, Suite 101
Tempe, AZ 85284
(480) 893-8349 p
(480) 893-3846 f
janet@waibel-la.com
www.waibel-la.com
NEW 6' CMU BLOCK WALL
NEW 6' SIDEWALK
OPEN
SPACE
OPEN
SPACE
BUILDING
BUILDING
BUILDING
EXISTING TREE