TAC Review Comments

City of El Mirage — Regular Meeting (2022-10-04)

View PDF Item 1 Meeting page

Extracted text (via pymupdf) 20451 characters
PLANNING AND ZONING 
Development Services Department 
10000 N. El Mirage Road, El Mirage, Arizona 85335 
623-876-2996; Fax 623-876-4605; TDD 623-933-3258 
www.elmirageaz.gov 
 
 
MEMORANDUM 
TO: 
 
John McGhee  
FROM:  
Jose A. Macias, Senior Planner 
 
 
Development Services Department, Planning & Zoning  
RE: 
 
PZ22-07-22 SFG Warehousing/Distribution  
DATE:  
August 31, 2022 
Mr. McGhee, 
Please see the comments from the El Mirage Technical Advisory Committee (TAC) for the 
Warehousing/Distribution Center.  
BUILDING & SAFETY 
1. No comment. 
ECONOMIC DEVELOPMENT  
2. No comment. 
ENGINEERING 
3. See attached memorandum.  
FIRE DEPARTMENT 
4. No comment.  
PLANNING & ZONING 
5. Landscape Plan: The plan is 14 trees short of satisfying the requirement of 50% of trees 
shall be in a 24” box.  
6. If required, a final plat shall be submitted for City Council approval to record all 
easements and/or dedication of land prior to issuing the Certificate of Occupancy. 
(Separate application and additional fees will apply) 
POLICE DEPARTMENT 
7. No comment.  
PUBLIC WORKS 
8. No water/wastewater comments.

Engineering 
Development Services Department 
10000 N El Mirage Road, El Mirage 85335 
623-972-8116; Fax 623-876-4605; TDD 623-933-3258 
www.elmirageaz.gov 
 
 
MEMORANDUM  
 
TO: 
 
Jose Macias, Planner/GIS 
FROM: 
Bryce Christo, P.E., Assistant City Engineer 
SUBJECT: 
SFG Warehouse Development Application Review  
DATE: 
08-30-22 
 
Below are the Engineering Department’s comments for the above referenced submittal provided 
in August 2022. These items will have to be addressed prior to the Planning and Zoning 
Meeting. 
 
1. The minimum distance between the proposed east driveway and 121st Avenue is 350 feet, 
measured from nearest face of curb to nearest face of curb. Please verify that this distance 
is met and, if not, a Design Exception (see attached) will have to be submitted for review. 
 
The below items will have to be addressed during the Construction Plan Submittal. 
 
Site Plan/Civil Plans  
2. Show the boundary line of the parcels with dimensions. 
3. The plans will have to show the following: 
a. Exterior signs 
b. Exterior lighting 
4. Joe R. Ramirez Road (collector road), in the ultimate condition, shall be a 40 foot wide 
roadway within a 60-foot right of way. The SFG Warehouse project is responsible for the 
following: dedicating the right of way (varying from 30 feet on the west side to 60 feet on 
the east side), constructing the south half of Ramirez Road (25 feet wide minimum) to 
121st Avenue, dedicating an 8-foot wide Public Utility Easement (PUE), extending the 12 
inch ductile iron water main from the existing stub to the 6 inch main in 121st Avenue 
with hydrants, installing curb and gutter, installing any drainage requirements, installing 
signing & striping, placing decomposed granite (DG) within the right of way, installing a 
streetlight at any proposed driveway and installing a fire truck turnaround per City Detail 
EM-114. The project will also be responsible for any required deceleration lanes and 
associated right of way widening. A set of offsite plans, including profiles will be 
required showing the above items. 
5. A 2 foot wide sawcut into the existing Ramirez Road pavement will be required to tie the 
new asphalt into the road. Where no asphalt for Ramirez Road exists, the edge of 
pavement shall be a thickened edge per MAG Detail 201 – Safety Edge. 
6. Ramirez Road shall be designed per City Detail EM-111 and Chapter 3 of the City’s 
Design and Development Standards Manual (DDSM). 
7. Provide  a corner radii dedication at the southwest corner of the Ramirez/121st Avenue 
intersection per City Detail EM-161.

2 
 
8. There is an existing 30 feet of right of way for the 121st Avenue alignment (collector 
road) located along the east boundary of the subject property. The only requirement from 
the SFG Warehouse project along 121st Avenue, at this time, is the dedication of an 8-
foot wide PUE. If the project wishes to construct a driveway along 121st Avenue, the 
project would also be responsible for the following: constructing the west half of 121st 
Avenue (25 feet wide minimum), installing curb and gutter, installing any drainage 
requirements, installing signing & striping, placing DG within the right of way and 
installing a streetlight at the proposed driveway.  
9. Label the 121st Avenue alignment on all of the plans. 
10. The City has previously constructed the roadway section for El Mirage Road (arterial 
road). The SFG Warehouse project is responsible for dedicating an 8-foot wide PUE, 
installing an 8-foot-wide (meandering if possible) sidewalk, streetlights and 
landscaping/irrigation along the frontage. The project will also be responsible for any 
deceleration lanes and associated right of way/easement revisions. The Site Plan 
incorrectly calls out the sidewalk to be 6 feet wide. 
11. The “Project Information” and “Parking Calculations” Sections shows the proposed 
building as 216,320 square feet but all other plans and reports show 216,820 square feet. 
Which is correct? 
12. The driveways shall be per MAG or City details. Stop signs are recommended at each 
driveway.  
13. Verify that any driveway to be used by a truck can accommodate a WB-67 vehicle 
without encroaching into the adjacent lane. 
14. Show the sight distance requirements at the proposed driveways and intersections, 
including the El Mirage/Ramirez intersection, per City Detail EM-158.  
15. The City recommends that the two parcels share the east driveway/drive aisle. The 
minimum spacing between driveways on collector streets is 150 feet, measured from 
nearest face of curb to nearest face of curb. This requirement along with the spacing 
referred to in Comment #1, would not allow the outparcel to have a driveway on Ramirez 
Road. 
16. 6-inch MAG type curbing is required around all driveways and parking lots. The curbing 
shall be no closer than 3 feet to any property line.  
17. Any fire access road shall be designed to handle 75,000 lbs. or more. A Geotechnical 
Report will be required for this project and it should provide a recommended design 
section for this access road and all other pavement sections including offsite roadways.  
18. Provide a 20 foot wide template to show how emergency vehicles will maneuver through 
the site, using an inside radius of 19.5 feet and an outside radius of 45 feet.  
19. The 4 acre parcel, once developed, will also be required to accommodate the drainage 
from the parcel and the adjacent half right of way of 121st Avenue along its frontage.   
20. There are existing basins within Drainage Easements at the southwest and northwest 
corner of the property.  Upon development of the parcel, the easements will be 
extinguished by the City but the scuppers will remain and the site will have to retain the 
flow from these areas. The basins can be reconfigured as necessary. The registration of 
any existing dry wells will have to be transferred to the new property owner. 
21. The trash enclosures shall be per City Detail EM-113. 
22. No noise shall be generated at the site that exceeds 55 decibels, measured at any property 
line, between 10 pm and 6 am. 
23. Plans shall include applicable City Notes. Call out MAG, City, etc. details to be used. 
Use the City’s Design & Development Standards Manual (DDSM) as a guide for the final 
design.

3 
 
Preliminary Grading & Drainage Plan 
24. Verify the slope does not exceed 2% in any direction within the ADA parking spaces. 
25. Side slopes adjacent to the public right of way, areas where pedestrian access is permitted 
and within Public Utility Easements (PUE) shall be 6:1 or flatter. There shall be at least 
two feet of level ground between any wall or vertical obstruction and the top of any side 
slope grading.  
26. The proposed retention basin(s) shall be located a minimum of 4 feet away from any 
structures and shall not be located within any building setbacks, easements, or fire 
lanes. Basin 2 appears to be within the PUE and Basin 3 appears to be within the building 
setback. Revise as necessary. 
27. Label the basin overflow elevations for each basin and the ultimate outfall elevation for 
the site. The finished floor of the proposed building shall be 14 inches above the ultimate 
outfall. 
28. Any proposed scuppers require a non-galvanized safety rail painted “Black Bean” 
(SW6006).  
29. Any proposed scupper or catch basins will require inlet markers per City Detail EM-559. 
30. Trash racks and safety rails are recommended for on-site headwalls. 
 
Preliminary Utility Plans 
31. The Utility Plans shall show all utilities and utility easements including electric, gas, 
telephone and cable, if applicable. 
32. Do not install utilities under any driveways or adjacent concrete aprons. 
33. Onsite sanitary sewer and water mains/services will be private. 
34. Fire hydrants shall adhere to City Details EM-360, 361 and 362. If bollards are required, 
they shall adhere to City Detail EM-364. The backflow preventers shall adhere to City 
Details EM-351, 352 or 353.   
35. The actual tie in location of the Ramirez Road water line is where the plans show the 
proposed water line crossing the property line.  A copy of the Ramirez Road plans can be 
provided via a Request for Public Record (see attached).  
36. Water valves are required along the Ramirez Road water main and the private fire line, 
approximately every 500 feet, and at locations so that the maximum number of hydrants 
to be out of service is two. 
37. Rather than tying into the water main in Ramirez Road twice, the proposed on site water 
shall tap the mains in both Ramirez Road and El Mirage Road. 
38. Hydrant location/spacing will be reviewed and approved by the Fire Department. 
Hydrants shall be spaced every 300 feet along Ramirez Road. 
39. All structures and above ground utilities shall maintain a minimum of 6 feet of clearance 
from all fire hydrants and fire suppression devices per City Detail EM-361. 
40. Any hydrants within the project site will be private and painted “Safety Red” per City 
Detail EM-360. Any hydrants within City right of way will be public and painted “Safety 
Yellow” per City Detail EM-360. All hydrants require markers per MAG Detail 122. 
41. The 6-inch north-south sanitary sewer lines that connect to the building will be 
considered services and shall adhere to City Detail EM-440-1.  The 6-inch east-west 
sanitary sewer line that connects to El Mirage Road will be considered the main and shall 
adhere to City requirements for sewer main including maintain a slope to allow a velocity 
of 2 fps. The sewer between the last two manholes shall be sloped at 1.00%. 
42. A manhole will be required at the sewer tap in El Mirage Road per City Details EM-420 
and EM-423.  The manhole shall receive an epoxy coating per City specifications. 
43. The proposed building will require a backwater valve per City Detail EM-442.

4 
 
44. See Section 6-3 of the City’s Design and Development Standards Manual (DDSM) to 
determine if a pretreatment device is required. 
45. Show utility horizontal and vertical clearance information per MAG Detail 404 and City 
Detail EM-402. 
46. Each proposed driveway shall have at least one streetlight. 
47. Any light or combination of lights which cause light on a public street, other than lights 
specifically intended for that purpose, shall not exceed one foot candle as measured from 
the center line of the street. Show the foot candles along the centerline of El Mirage Road 
and Ramirez Road to verify that the proposed lighting will not exceed the maximum 
limit. 
 
Preliminary Landscape Plans 
48. Add City Landscaping and Irrigation Notes (City Detail EM-101-4) to the plan set. 
49. Show the sight distance requirements at the proposed driveways and intersections, 
including the El Mirage/Ramirez intersection, per City Detail EM-158.  
50. A separate landscaping service, meter and backflow preventer is required. 
51. All plantings at maturity shall maintain a minimum of 6 feet of clearance from all fire 
hydrants and fire suppression devices per City Detail EM-361. 
52. No walls or trees shall be placed within the Public Utility Easement (PUE). It appears 
many trees are within the PUE along Ramirez Road. 
53. Trees shall not be placed within 5 feet of any City curb or sidewalk or within 6 feet of 
any public utility. 
54. Palo Verde and Sisso trees are not allowed in the City. 
55. Add a note to the plans that the maintenance for all landscaping and irrigation shown on 
the plans will be the responsibility of the property owner. 
56. Irrigation plans will be required. 
 
Drainage Area Map 
57. The below revisions to the drainage areas appear to be necessary (see the attached 
redlines): 
a. Offsite areas need to run to the right of way line 
b. Basin 4 needs to accept the drainage from the proposed temporary cul-de-sac. 
c. A scupper or similar drainage feature shall be placed at the west end of Ramirez 
Road. 
d. Based on the City’s El Mirage Road design, the areas in El Mirage Road are 
slightly different than shown.  If the areas shown are correct based on the latest 
survey, then this comment can be ignored. 
 
Exterior Elevations 
58. No comments. 
 
Preliminary Drainage Report 
59. Section B1 – Using a coefficient of 0.95 for the whole is acceptable but the designer may 
also use the Runoff Coefficients per City Code Section 155.054(B)(6)(a). Concrete = 
0.95, roofs/asphalt = 0.85, grass = 0.15 and desert/rock lawn = 0.70.  
60. Section B2 – The side slope adjacent to right of way, including the slope of the basins, 
shall be 6:1. 
61. Appendix A – See Comment #57 regarding the boundaries of the Tributary Areas.

5 
 
62. Collector streets, such as Ramirez Road, shall be  designed to carry 10-year flows 
between the curbs and 100 year flows within the right of way. Provide calculations to 
verify these capacities are met. 
63. Provide calculations for storm drain sizing, scupper openings and inlet capacity. 
 
Preliminary Water Report  
64. Section C – The existing water main in El Mirage Road is a 16-inch ductile iron pipe. 
The existing water main stub in Ramirez Road is a 12-inch ductile iron pipe.  
65. Section 4.2.2 - The developer is required to perform their own flow test. The City’s Fire 
Department (623-583-7968) shall be contacted as a witness. Also notify the Public Works 
Department (623-876-4251) one week prior to the test. 
66. It is understood that the sizing of the fire line and domestic water will be done during the 
construction document phase.  The minimum size of the fire service shall be 6 inches. 
 
Preliminary Sewer Report  
67. Section A – The existing sanitary sewer main in El Mirage Road is a 12-inch PVC pipe. 
 
Traffic Impact Statement (TIS) (An updated TIS was not provided with the Development 
Application) 
68. Determine whether the existing southbound left turn lane on El Mirage Road is sufficient 
for the proposed site. A northbound 11.5 foot wide deceleration lane is required along El 
Mirage Road. Determine whether deceleration lanes are required along Ramirez Road per 
the City’s Auxiliary Lane Criteria (attached). 
 
ALTA Survey 
69. Show the existing Drainage Easements referenced in Comment #70. 
 
Deed 
70. Exception 16 of Schedule B – Part II refers to two existing Drainage Easements that are 
not shown on the ALTA of any of the plans.  These easements shall be shown on the 
plans to be extinguished by the City. 
 
Phase I Environmental Site Assessment 
71. Section 2.3 – The Site Reconnaissance Summary shows the site has no “drywells, 
retention basins, stormwater drains or other stormwater features” but the site has two 
retention basins, each with their own scupper and drywell. 
72. Section 7.1 – It is noted that the ADEQ online databases indicated no records of drywells 
but the site has two. 
73. Appendix B – Photos 1 and 10 refer to the southwest portion of the site but the photos are 
showing the southeast portion. 
 
Miscellaneous 
74. A Final Plat will be required prior to Certificate of Occupancy. The Plat shall show the 
following: 
a. All right of way and easement dedications. 
b. A 1-foot Vehicular Non-Access Easement is required along El Mirage Road. 
c. The proposed outparcel and note any cross access easement that may be required 
between the two parcels. 
75. A Geotechnical Report will be required to provide on-site pavement sections. Verify the 
proposed pavement sections can handle 75,000 lbs. for the fire access lane.

6 
 
76. A Haul Permit will be required if 500 cubic yards or more of material will be brought 
into or out of the site. This will require a separate application, an exhibit showing the haul 
route and insurance from the company performing the haul. The fee is $300. 
77. An Approval to Construct (ATC) will be required from MCESD for the water and sewer 
line extensions. A copy shall be provided to the City prior to the release of any 
Engineering permit. 
78. A Dust Control Permit from the County will be required prior to the release of any 
Engineering permit. 
79. A Stormwater Pollution Prevention Plan (SWPPP) will be required per the City’s SWPPP 
Guidelines document. A Notice of Intent (NOI) from ADEQ will be required prior to 
release of any Engineering permit. 
80. Any cutting of the pavement in the El Mirage Road will require Pavement Cut Fees per 
the most current Fee Schedule. 
 
The above comments are meant to be general in nature and are not considered to be all inclusive. 
Additional comments will arise during the formal permit submittal.

N. EL MIRAGE RD.
W. JOE R. RAMIREZ RD.
A.P.N. 501-45-014R
A.P.N. 501-45-014R
C4.0
Job Number
Sheet Number
22-0133
INSTALL A 
SCUPPER OR 
CATCH BASIN 
HERE
CL x CL 
STA 165+77.94
HIGH POINT 
STA 163+32.11

DEVELOPMENT SERVICES  
ENGINEERING DIVISION 
10000 N. El Mirage Road 
 
 
El Mirage, AZ 85335 
Phone:  623-876-2974 
www.elmirageaz.gov 
 
 
REQUEST FOR DESIGN EXCEPTION 
 
Applicant Information  
 
Name: 
 Telephone:_
 
Address:_
 City:_
 State:
 
E-mail:
 
Name of Development: 
 Permit No.:
 
Describe the Request:  
 
1. Cite City of El Mirage Design & Development Standard or condition of approval that you are requesting the 
Design Exception for. 
 
 
 
2. Reason that the Exception is needed. 
 
 
 
3. Impacts of granting the Exception. 
 
 
 
4. Alternatives to granting the Exception. 
 
 
 
 
 
 
____
 
Applicant 
 
 
 
 
 
 
 
Date 
 
 
 
For Office Use Only 
 APPROVED            DENIED 
Comments:_
 
____
 
____
 
____
 
____
 
City Engineer or Assigned Designee 
 
 
 
 
Date

CITY OF EL MIRAGE, ARIZONA 
Request for Public Records 
ROUTING 
(A.R.S. Title 39) 
TO: 
 
RETURN COMPLETED FORMS TO CITY 
CLERK either 1) in person 
2) email santes@elmirageaz.gov 
or 3) Fax 623-876-4203 
NAME: 
DATE: 
NUMBER OF COPIES MADE 
AGENCY NAME: 
ADDRESS: 
PHONE 
CHARGES ARE BASED ON 
ESTABLISHED FEES 
CITY 
STATE 
ZIP 
TOTAL AMOUNT DUE 
PLEASE NOTE: Active public records are in various locations within the City. The City requests that a reasonable amount of 
time be expected for responding to any request to copy or inspect City records. The City may require additional time to process 
more difficult requests and if so, an estimated time frame will be provided to the requestor. 
Indicate whether you desire to inspect 
or copy public records 
Inspect 
Copy 
Specifically describe the record requested for inspection or copying: 
Indicate whether you are using the 
public record for a commercial or non- 
commercial purpose. 
Commercial* 
Non-Commercial 
* A.R.S. 39-121.03D –Commercial purpose includes any use of a public record for the purpose of sale or resale or for the purpose of 
producing a document containing all or part of the copy, printout or photograph for sale or the obtaining of names and addresses 
from pubic records to another for the purpose of solicitation or for any purpose where the purchaser can reasonably anticipate the 
receipt of monetary gain from direct or indirect use of the record. When a person requests copies of City records for commercial 
purposes, a statement setting forth the commercial purpose for which the copies will be used must be provided. 
Commercial Purpose Statement 
FOR CLERK OFFICE USE ONLY 
 
DATE RECEIVED:  
  
 BY: 
DATE PROCESSED:  
  
LOC: 
REQUEST APPROVED: 
REQUEST DENIED: 
COMPLETION DATE/INITIALS