Part 2 of Mohave Purchasing Agreement & Award Letter
Extracted text (via ocr_local)
29326 characters
5d . AN AMERICAN LEADER IN-SUN/UV PROTECTION TAB 2D Confidential Fianancial information Removed Shade ‘N Net Corporate Office + 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com Fd , _AN AMERICAN LEADER IN-SUN/UV PROTECTION Shade ‘N Net Corporate Office * 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com Primary Vendor Information Qualifications and Experience (Place after Tab 2b, 2d, 2e & 2f — As Noted Below) 5. Place after Tab 2b: Provide copy(ies) of one of the following current Arizona Registrar of Contractors license(s) A — General Engineering, B-1 General Commercial Contractor, B-2 General Small Commercial Contractor, C-3/CR-3 Awnings, Canopies, Carports and Patio Covers or CR-5 Restricted by Registrar license from the Arizona Registrar of Contractors held by your company (Specification 1.1.10 requirement). For those bidders submitting under a CR-5 license, provide proof that the restricted license allows for shade structures/shelters. If applicable, provide a copy of the Arizona Registrar of Contractors application receipt with pending number (Specification 1.1.11 requirement). 6. Place after Tab 2d: Provide a current letter from your financial institution indicating the range of credit available to your firm, (e.g., “credit in the low nine figures” or “credit line exceeding five figures”). Provide a current letter from your financial institution and/or officers of major suppliers, indicating confidence in your firm’s stability and payment history. 7hese /etters will only be used to evaluate bids and will not be made available to the public. Bidders may submit current audited annual financial reports in lieu of letters from financial institutions. However, the annual financial reports must provide essentially the same information as requested from the letters. Bidders are encouraged to highlight the requested information in any audited annual financial report submitted in response to this solicitation. All financial information will be kept confidential. 7. The 2018 International Building Code (IBC) provides a definition in Chapter 2, Definitions for a Tensile Membrane Structure (e.g. Shade Structure), as being "A membrane structure having a shape that is determined by tension in the membrane and the geometry of the support structure. Typically, the structure consists of both flexible elements (e.g. membrane and cables), nonflexible elements (e.g. struts, masts, beams and arches) and the anchorage (e.g. supports and foundations.” These structures are further defined in IBC Chapter 16, Table 1604.5 to be classified as Risk Category Type II buildings or other structures. The ultimate design wind speeds for Risk Category II buildings and other structures are shown in Figure 1609.3(1). Provide answers and evidence that the shade structures being provided in your bid meet the following requirements: a. Ata minimum, entire shade structure can withstand a 3-second wind gust speed of 110 MPH. Provide shade structure manufacturer specifications that clearly state that the structures being bid meet or exceed the requirements of the 2018 International Building Code. Place manufacturer specification after Tab 2e. All shade structures are designed in accordance with IBC 2018 and the American Society of Civil Engineers (ASCE) Standard 7-16 for a 3-second wind gust speed of 110 MPH. Net pressure coefficients are applied in accordance with ASCE 7-16 Figures 27.3-4 and 27.3-5 for Open Buildings. Manufacturer Specifications are attached in Tab 2e. b. Your sealed engineering drawings shall provide the minimal information required in IBC Chapter 16, Section 1603 Construction Documents. Confirm that the sealed drawings provide meet the minimal information required. Please see following pages for signed letter from our structural engineer, answering these items. Also, find a set of Sealed Engineering Calculations and drawings as evidence. We confirm that the sealed drawings provided meet the minimal information required. Drawings under Tab 2e. IFB 20Q-0107. 2 2 SHADE ‘N NET SHADE STRUCTURE SPECIFICATIONS PART 1 GENERAL 1.1 SUMMARY A. The shade structure contractor shall be responsible for the design, engineering, fabrication, supply and installation of the work specified herein. The intent of this specification is to have only one contractor be responsible for the above functions. 1.2 REFERENCES A. Shade structures must comply with the latest revision of applicable codes and regulations including IBC 2018. B. American Society for Testing Materials (ASTM). C. American Welding Society: Structural Welding Code AWS D1.1: Symbols for Welding and Nondestructive Testing AWS 2.4: 2020. D. American Institute of Steel Construction (AISC): Specifications for the design, fabrication and erection of structural steel. 1.3 SUBMITTALS A. Contractor can provide evidence of installed reference sites with structures for similar scope of project and installation that are engineered to IBC 2018 specifications. Include in reference list of structure dimensions with install dates and project locations. B. Contractor can provide manufacturer’s range of fabric samples to demonstrate fabric color range and powder coat color selections for final order selection. Also provide letter of authorization from fabric manufacturer for use of fabric. C. Contractor can provide evidence of all quality assurance items including: 1. A list of at least 10 reference projects that have been installed a minimum of 10 years. 2. Proof of liability and umbrella insurance as required. D. Contractor can provide wet sealed structural engineering drawings and calculations from an Engineer licensed by the state in which the jobsite is located. 1.4 QUALITY ASSURANCE A. Manufacture and installation are limited to firms with proven experience in design and fabrication of fabric shade structures and such firms shall meet the following minimum requirements. No substitutions shall be allowed for the following: 1. A single contractor shall engineer, design, fabricate and install the fabric shade structures including the foundations. Shade ‘N Net Corporate Office * 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 » Office 602-484-7911 ¢ Fax 602-484-7919 * www.Shade-N-Net.com # Ff 2. Allcontractors shall have at least 15 years experience in the design, engineering, fabrication, and installation of structures, engineered to IBC requirements with similar scope and a successful construction record of in- service. 3. All contractors shall be able to provide proof with bid submittal of a minimum of $1,000,000 general/public liability insurance, and additional $5,000,000 umbrella/ excess liability insurance with the ability to obtain professional liability (PL or E&O) insurance if required by project. All contractors shall be licensed and have the ability to be bonded. Manufacturer shall be accredited as a Clark County, Nevada Approved Steel Fabricator on record with one or more qualifying municipalities or agencies such as Clark County, Nevada; City of Phoenix, Arizona; and City of Los Angeles, California, etc. The certification should verify that the manufacturer meets or exceeds the necessary criteria, including, but not limited to: an in- house quality control program, use of only AWS certified welders, and it maintains material traceability documentation. 6. The shade contractor shall have a Corporate Quality Control program and manual describing their complete quality assurance program. 7. Allcontractors must have an in-house warranty and service department and local office to assist in repairs and service calls. 8. All contractors shall be a licensed contractor for at least 10 years in the State of Arizona and shall be bonded and provide proof of a minimum bonding capacity as required by the job or regulating authority. we 1.5 WARRANTY A. Contractors shall provide a 12-month warranty on all labor and materials. B. A supplemental warranty from the manufacturer shall be provided for a period of 10 years (pro-rated) on fabric and 20 years on the structural integrity of the steel from date of substantial completion. C. The warranty shall not deprive the Owner of other rights the Owner may have under the provisions of the Contract Documents and will be in addition to and run concurrent with other warranties made by the Contractor under requirements of the Contract Documents. D. Because of surety requirements, any performance and payment bond that may be required will cover only the first year of the warranty. The manufacturer’s warranty will be a separate document between them and the Owner, and will be executed at the time of completion of the work. PART 2 PRODUCTS Shade ‘N Net Corporate Office + 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com AN AMERICAN LEADER IN-SUN/UV i | Oo PROTECTION 2.1 GENERAL Pre-Engineered Package: The proposed structure(s) fabricated or approved equal shall be modular and pre-fabricated, and include the structural steel frame, multi-panel fabric roof, steel cables, all fasteners, and installation of structure(s) including foundations. A. Shade ‘N Net of Arizona manufactured structure shall be used or approved equal. B. Alternate suppliers must meet the qualifications and provide proof of certification listed under paragraph 1.4 — Quality Assurance. C. Structures shall qualify for up to 8 LEED Credits D. All shade structures are engineered and designed to meet: 1. Up to 115 mph wind load 2. 10 psf snow load 3. 20 psf live load E. Steel: 1. All steel members of the shade structure shall be designed in strict accordance with the requirements of the “American Institute of Steel Construction” (AISC) Specifications and the “American Iron and Steel Institute” (AISI) Specifications for Cold Formed Members and manufactured per IBC 2018. 2. All non-hollow structural steel members shall comply to ASTM A-36. All hollow structural steel members shall be cold formed, high strength steel and comply with ASTM A-500, Grade B. All steel plates shall comply with ASTM A-572, Grade 50 and shall be rust/corrosion treated. All galvanized steel tubing shall be triple coated for rust protection using an in-line electro-plating coat process. All galvanized steel tubing shall be internally coated with zinc and organic coatings to prevent corrosion. 3. Steel pipe columns shall be ASTM A-53, Grade B, unless otherwise noted. 4. Slip fittings shall be fabricated using drawn-over-mandrel (DOM) steel with minimum yield strength of 70 kis and a minimum tensile strength of 80 ksi. 5. All connections shall have a maximum internal sleeving tolerance of .0625 inches using high tensile strength steel sections with a minimum sleeve length of 6 inches. 6. Framing for top support shall be: i, 2.5” Diameter, round steel tubing and .120 thick ii. 3” Diameter, round steel tubing and .120 thick iii. 3.5” Diameter, round steel tubing and .120 thick iv. 4” Diameter, round steel tubing and .188 thick v. 5” Diameter, round steel tubing and either .120 or .188 thick F. Bolts: Shade ‘N Net Corporate Office * 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com 7 ‘ . } 1. All structural field connections used for erection purposes of the shade structure shall be designed to retard corrosion and made with high strength bolted connections using ASTM A-325 galvanized bolts. 2. Allstainless steel bolts shall comply with ASTM F-593, Alloy Group 1 or 2. All bolt fittings shall include rubber washer or silicone gel for water tight seal at joints. All nuts shall comply with ASTM F-594, Alloy Group 1 or 2. 3, Bolts and other connection hardware shall be based on calculated engineering loads. G. Welding: 1. All shop welded connections of the shade structure shall be designed and performed in strict accordance with the requirements of the “American Welding Society” (AWS) Specifications. Structural welds shall be made in compliance with the requirements of the “Prequalified” welded joints where applicable and by certified welders. No onsite or field welding shall be permitted. 2. All full penetration welds shall be continuously inspected by an independent Inspection agency, and shall be tested to the requirement of IBC 2018 and local agency additions and amendments. 3. Grind all welds smooth. H. Powder coating: 1. Steel tubing preparation prior to powder coating shall be executed in accordance to solvent cleaning SSPC-SP1. Solvent such as water, mineral spirits, xylol, toluol, which are to be used to remove foreign matter from the surface. A mechanical method prior to solvent cleaning prior to surface preparation shall be executed according to Power Too! Cleaning SSPC- SP3 and utilizing wire brushes abrasive wheels and needle gun, etc. 2. Carbon structural steel tubing preparation prior to powder coating shall be executed in accordance to commercial blast cleaning SSPC-SP6 or NACE #3. A commercial blast cleaned surface, when viewed without magnification, shall be free of all visible oil, grease, dirt, mill scale, rust, coating, oxides, corrosion, products and other foreign material. 3. Powder coating shall be sufficiently applied, with a minimum 3 mils thickness, and cured at the recommended temperature to provide proper adhesion and stability to meet salt spray and adhesion tests as defined by the American Society of Testing Materials. 4. Powder used in the powder coat process shall have the following characteristics: a. Specific Gravity: 1.68 +/- 0.05. b. Theoretical coverage: 114 +/- 4ft?/Ib/mil Shade ‘N Net Corporate Office * 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com JAN AMERICAN LEADER IN-SUN/UV PROTECTION, c. d. Mass loss during cure: <1% Maximum storage temperature: 75°F I. Tension Cable: Steel cable is determined based on calculated engineering load. 1. For light and medium loads: %” (nominal) galvanized 7x19 strand cable to be used. 2. For heavy loads: either 3/8” (nominal) or %” galvanized 7x19 cable is to be used. J. Fabric Roof Systems: 1. UV Shade Fabric: a. UV shade fabric is made of UV stabilized Commercial 95® or Alnet Extra Block™ cloth manufactured by Gale Pacific and Alnet, respectively and made of a UV stabilized high-density polyethylene. Mesh shall be Rachel-knitted with monofilament and tape filler to ensure that material will not unravel if cut. Panels to be 10 feet wide. Fire Testing: Fabric shall conform and pass the ASTM E84 testing standard as well as NFPA 701-97. *CA Fire Marshall Rating Title 19, Section 1237. The fabric knit is to be made using monofilament and tape filler which has weight of 195g per square meter. Fabric material shall cover all exposed cable and connectors at terminal locations. Material is to be Greenguard® and OEKO-TEX® certified for air quality assurance. Fabric Properties (Approximate): Stretch Stentored Fabric Weight (oz): 10 Fabric Width: 10 ft. Roll Length: 164 ft Roll Size: 63” x 16.5” Weight: 68 Ib. Life Expectancy: 10 years in sun Fading Minimum: Fading after 6 years (3 years for red) Temperature: -22°F Maximum Temperature: + 176° F Burst Strength: 353 Ibs Tear Strength: Warp — 51 Ibs., Weft — 52 lbs. 2. Stitching & Thread: a. All sewing threads are to be double stitched. Shade ‘N Net Corporate Office » 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 ¢ Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com F b. Where steel cable enters or exits the netting hems and pockets, protective webbing shall also be double stitched. c. Thread shall be GORE Tenara Sewing Thread manufactured form 100% expanded PTFE; mildew resistant exterior approved thread. Thread shall meet or exceed the following: ii. Flexible temperature range iii. Very low shrinkage factor iv. Extremely high strength, durable in outdoor climates v. Resists flex and abrasion of fabric vi. Unaffected by cleaning agents; acid rain, mildew, salt water and rot resistant, unaffected by most industrial pollutants. vii. Treated for prolonged exposure to the sun. 3. Sewing thread shall be warranted for the life of the fabric against shrinkage and deterioration from exposure to the elements. 4. Stitch Patterns shall include Lockstitch — 1200 Denier and Chainstitch — 2400 Denier as appropriate. 5. Attachment: Each fabric panel is to be secured with two (2) perimeter cables and all corners shall be strengthened with 160z. non-tear cloth and strap to distribute load. 6. Sewing thread shall be made of 100% expanded PTFE (polytetrafluorethylene): e Temperature Range: -212°C to 260°C (-350°F to 500°) e Thickness: ASTM D4851 1. 36mm (0.14 in) e Light Values: ATSM 903 1. Transmission: 32% 2. Avg 450-650mm 3. Reflection: 68% 4. Absorption: 0-1% e Strip Tensile: ASTM D4851 1. Warp: 2250 N/5 cm (260 Ib/in) 2. Fill: 2105 N/5 cm (345 Ib/in) e Weave Style: ASTM D1777 1. Twill 330g/m2 (9 75 oz/yd?) e UV Resistance: Unaffected by UV Light Flex Resistance: Unlimited Trapezoid Tear: ASTM D5587 1. Warp: 347 N (78 Ibs) Shade ‘N Net Corporate Office * 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com AN AMERICAN LEADER IN-SUN/UV PRQ TECTION \ | 2. Fill: 347 N (79 Ibs) e Flame Propagation: Pass NFPA 701 small scale Burn Characteristics: ASTM E84 1, Flame Spread: 0 2. Smoke Index: 0 ¢ Ignitability: Pass BS 7837-96 BS 5438.2B © Vertical Flaming: V-OUL 94V e Limiting Oxygen Index: (LOI) >95% e Chemical Resistance: 1. Resistant to all alkaline solutions and acids from 0-14 pH and all organic solvents over the temperature range. K. Shade and UV Factors: 1, Shade protection and UV screen protection factors shall be as follows: Color Shade Factor UVR Block Out% NATURAL CREAM 74.3 96.8% DESERT SAND BEIGE 85.0 96.4% CEDAR 87.7 94.7% YELLOW 77.2 97.1% CHERRY RED 75.3 89.3% CAYENNE 87.0 94.0% DEEP OCHRE - TERRACOTTA 91.3 94.4% SKY BLUE 90.4 93.8% TRUE BLUE — AQUATIC BLUE 90.2 93.6% NAVY BLUE 94.4 95.2% RIVERGUM GREEN - MINT 85.0 92.3% TURQUOISE 90.0 94.3% BRUNSWICK — FOREST GREEN 93.9 95.1% STEEL GREY - SILVER 88.4 93.0% GUN METAL - CHARCOAL 96.2 97.7% BROWN 93.0 94.6% BLACK 97.4 94.4% PART 3 EXECUTION 3.1 INSTALLATION A. Installations of shade structures shall be performed by a licensed and bonded contractor by the State of Arizona. B. The contractor installing the structure shall comply with manufacturer’s instructions for assembly, installation, and erection per approved drawings. C. Layout: Locate columns a minimum of 6’-0” clear from any safety fall surfaces. D. Concrete: Shade ‘N Net Corporate Office * 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 » www.Shade-N-Net.com B Be 1. Unless noted otherwise for footing and piers by General Contractor’s Engineer, concrete specification for footings, piers, slabs, curbs and walkways shall meet a minimum 3,500 psi at 28-day strength. 2. Concrete work is executed in strict accordance with the latest edition of American Concrete Building Code (ACI 318-99). 3. Slump: 4” maximum. 4. Whenever daily ambient temperatures are below 80 degrees F, the contractor may have mix accelerators and hot water added at the batch plant. a. Temperature range between 75-80 degrees, 1% accelerator High Early (non-calcium). b. Temperature range between 70-75 degrees, 2% accelerator High Early (non-calcium). c. Temperature range below 70 degrees, 3% accelerator High Early (non-calcium). 5. The contractor shall not pour any concrete when daily ambient temperature is below 55 degrees F. E. Foundations: 1. Allanchor bolts set in new concrete shall be ASTM F1554-55 Galvanized. 2. Cast in-place Anchors shall be Grade 1554-55, 74” x 16” with a minimum embedment of 12”. 3. Foundations shall be designed using allowable soil bearing value of 1,500 psf for spread footings. 4. Footing sizes shall be a minimum as listed below: i. Multi-panel structures are to have a minimum 24” x 30” D pier footings, or alternate minimum 3” x 3’ x 2’ D spread footings, and placed in accordance with and conform to manufacturer’s engineered specifications and drawings. F. Reinforcement Steel: 1. All reinforcement steel shall conform to 40,000 psi A706, Grade 60. 2. Reinforced steel shall be designed and manufactured and installed according to most current ACI procedures (SP-66) and CRSI Manual of Standard Practice. 3.2 SAFETY PROCEDURES A. All parties will be notified of the schedule and confirmed before starting installation. The Contractor is responsible for the coordination of work with other trades. B. All staff personnel are to be dressed and conduct themselves in accordance with OSHA standards. All staff must be properly trained for equipment that they might use. Shade ‘N Net Corporate Office * 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com r C. All vehicles and machinery are to be properly licensed and insured and must be operated by licensed operators in accordance with OSHA standards. All cranes and lifts must be operated in accordance with manufacturer’s guidelines. D. Handling of Steel During Installation: 1. Exercise care when lifting items so that it does not come into contact with other surfaces. 2. Clean sand and other deleterious material from structural items before moving or lifting. 3. Before installation, all items are to be washed with soap and water and dried with cloths. 4. All grease, dust, oils, and other latent materials are to be removed during this washing. 5. When pouring concrete pour backs at columns, protect paint by using plastic and tape to prevent concrete from splashing on finish surfaces. E. All concrete must be cut with a wet diamond blade to ensure that it leaves a clean finish. If at any stage the existing remaining surface lifts, creating a tripping hazard, additional saw cutting will be required so as to leave a neat and uniform joint. F. Cover all open holes at all times with solid plywood and spoils to prevent access until concrete is poured. G. All equipment and/or products must be stored inside the fenced area. Shade ‘N Net Corporate Office * 5711 W. Washington, Phoenix, AZ 85043 Toll Free 1-800-290-3387 * Office 602-484-7911 * Fax 602-484-7919 * www.Shade-N-Net.com FJS Engineering 4235 E Woodland Dr Phoenix, AZ 85048 Tel 480.696.3885 Ce he contact @fjsengineering.com | www. fjsengineering.com DESIGN| CONSULTING December 23, 2020 RE: Response to Proposal Questions To Whom It May Concern — The purpose of this letter is to provide responses to Request for Proposal (RFP) questions regarding design wind speed and IBC-required information in engineering drawings as related to shade structures. Statements form the RFP and questions are provided below, with responses provided in bold: The 2018 International Building Code (IBC) provides a definition in Chapter 2, Definitions for a Tensile Membrane Structure (e.g. Shade Structure), as being "A membrane structure having a shape that is determined by tension in the membrane and the geometry of the support structure. Typically, the structure consists of both flexible elements (e.g. membrane and cables), nonflexible elements (e.g. struts, masts, beams and arches) and the anchorage (e.g. supports and foundations).” These structures are further defined in IBC Chapter 16, Table 1604.5 to be classified as Risk Category Type II buildings or other structures. The ultimate design wind speeds for Risk Category II buildings and other structures are shown in Figure 1609.3(1). Provide answers and evidence that the shade structures being provided in your bid meet the following requirements: a. Ata minimum, entire shade structure can withstand a 3-second wind gust speed of 110 MPH. Provide shade structure manufacturer specifications that clearly state that the structures being bid meet or exceed the requirements of the 2018 International Building Code. All shade structures are designed in accordance with IBC 2018 and the American Society of Civil Engineers (ASCE) Standard 7-16 for a 3-second wind gust speed of 110 MPH. Net pressure coefficients are applied in accordance with ASCE 7-16 Figures 27.3-4 and 27.3-5 for Open Buildings. b. Your sealed engineering drawings shall provide the minimal information required in IBC Chapter 16, Section 1603 Construction Documents. Thesealed engineering drawings provide the following information, in accordance with IBC Section 1603: a. Live loads (roof live loads in this case) b. Snow loads: i. Ground snow load ii. Flat-roof snow load iii. Snow exposure factor iv. Snow load importance factor v. Thermal factor c. Wind loads: i. Ultimate design wind speed ii, Risk category iii. Wind exposure iv. Internal pressure coefficient (if applicable) d. Seismic design data: viii. xi. e. Risk category. Seismic importance factor. Mapped spectral response acceleration parameters Site class. Design spectral response acceleration parameters Seismic design category. Basic seismic force-resisting system Design base shear Seismic response coefficient Response modification coefficient Analysis procedure used. Flood design data (if applicable) f. Design load-bearing value of soils Sincerely, John Skwiot, P.E.* * Licensed in: Arizona California Colorado Florida Georgia Massachusetts Minnesota Mississippi Nevada New Mexico New York North Carolina Oklahoma Oregon Pennsylvania South Carolina South Dakota Texas Utah Virginia Washington (state) #47808 #76241 #43709 #78805 #041956 #54143 #46853 #27102 #20561 #19502 #96112 #43002 #28704 #93640PE #83305 #33371 #14792 #104240 #9560079 #0402056372 #53892 6S-02-ZVNS ‘ON ‘TOYd | 0202/60/90 ‘Alva st *GaNONddY | 3S ?A@ NMVUO NMOHS SV ‘vos | sr WaNgISad ¢82S8 ZV ‘AdWAL "dd TIANYOD “M 222 WO3"LAN-N-JOVHS "MMM £8£2-062-008-! £70S8 ZV ‘XINOHd NOLONIHSVM °M I1ZG AN N, S0VHS NU TAENOD I NOIEEG » “wo veniamls 6226 # Wald ZV a WODONISINIDNASPI19¥LNOD ONINSENISNS $e8¢'969°087 *1 87098 ZV 'XIN30Hd NOILdIdDS30 | “AY alva | 4d GNVTIG00M 3 S¢27 AYV.LNAWS13 GOOM___) SS SNOISIARE J onresaNrOna ST J 5 MalA NOLLWASTS emus MIA NOILWASTS EO ‘wat ~er02 8 32S 01 LON MalA NV 1d SYNLONYLS ro / ‘aaa wou aan . i Naa L450%3 "LN 30 “TivHS S8v ONIDUO IN ON TIVHS 3L3YINOO NI GIOQIONS SVE “INGE T109 99 savas “90c¥ Husy = ——=— 09 30ve3 ‘SIO WISY =~ GaVaT 00g (WOILINY H2e2 “3D.L7Ha ceteONTAS 40 TeTMRR NOwSTTa SUSAONO9 "WAN NLS 803 SHOU SEWTLGANLS WBHLO ONY SONIa ING YO. Sav 003 10 MMIN #91 bey IR@ TWNOHLYNAZLNI #102 ‘SdYVONVLS ONV S3d09 395 OL LON VLAD ALV 1d 428A arucien rat St SAWSINGD AY WAS *§ NOILOANNOD NAN109 OL 31V9 ¥ dIH AW2S OL LON 31v9$ 04 LON qiviad 31Vid eee or NOILOANNOO dIH OL 39qTe 0139 335 TWwaad des su Ws 358 9 ska oNNOND 1 TON 7 . ~ ~ y —, ~\ 6S-02-ZVNS “ON ‘Oud | 0202/60/90 :3Lv0 WOO “LAN-N-3QVHS"MMM gee _[ ‘ona 39sNOD | Noteaa ; @ Pas :A@ NMVua 28¢8-062-008-1 ~ ST Tae Ianons 62261 # Wild ZV se *M3N91S30 70S ZV "XINFOHd =o SES ink —— — = c WOD: SNDEEENISNAS( 2.9¥1NO cS $8268 ZV “AdW3L NOLORIESYIN OM ICS _ a oNnaaNIONS Se8S°969°084 “dd TIANYOD “M £22 13N N, aqVHS ee exe Nolaiosad [Aas | Siva | 4g UNYIa00m 3 $¢2"7 \ ASVINSWI1S GOOM_) (__2niomus avis SNOTSIAZRE onnssetons Sr . ZWv2s 01 LON WIS OL JON © CALCULATIONS: 60x40x14 Shade Canopy Wood Elementary 727 W. Cornell Dr. Tempe, AZ 85283 June 9, 2020 Total page count = 26 (including cover) Pages included: e Wind e Cables @ Members e Base Plates e Drilled Piers CONTACT INFORMATION: John Skwiot, P.E. FJS Engineering 4235 E Woodland Dr Phoenix, AZ 85048 (480) 696-3885 jiskwiot@fjsengineering.com AZ Firm #19229 WIND CALCULATIONS Wood Elementary Wind Load Calculations References: American Society of Civil Engineers (ASCE). "Minimum Design Loads for Buildings and Other Structures", Version 7-16. Input data: (Basic Wind speed | (Risk Category (Surface Roughness category | V=101 mph It c (wind Directionality Factor | (Enclosure type | (Exposure category | K,=0.85 Open Cc Topographic Factor K,,=1.0 (velocity Pressure Coefficient | K,=0.91 Gust Effect Factor G=0.85 (net Pressure Coefficient | Cu ww_roof =1.1 (net Pressure Coefficient Cc, ‘N_lw_roof — Velocity pressure 2 q, =0.00256-K, -K,,°Ky,*V°=20.2 psf —0.2 Roof (Windward design wind pressure | =1.0-°G,:G-Cy 18.9 psf P, ‘pos ww_rooft = (Leeward design wind pressure } =1.0-¢,:G6-C, —3.4339 pst Preg lw roof ~ Use 19 psf design windward pressure for roof | Use -4 psf design leeward pressure for roof | 9.3144 Case Net Pressure Coefficient | c, =0 [wet Pressure Coefficient | 1.0 C. == ©N in_roof . Velocity pressure eye =0.00256-K,-K,,-K,+V°=20.2 pst Windward design wind pressure | =1.0-¢,-6-¢, N_wa_roof =0 pst (Zeewara design wind pressure | 5 —-1.9- “Geo =- 1697 Preg =1.0°9, SG Cy Iw roof 17.1697 ps bh [Use 0 psf design windward pressure for roof | [Use -17 psf design leeward pressure for roof