PLANNING COMMISSION REPORT
CASE:
Cornerstone at Camelback PAD Amendment located at the NEC of
Camelback Road & 99th Avenue
CASE #:
GPA22-02 & ZON22-10
MEETING DATE:
08/25/2022
FROM:
Edward Vigil, Senior Planning Project Manager , Planning,
EVigil@glendaleaz.com, 623-930-3071
SUBJECT
GPA22-02 -ZON22-10 Minor General Plan Amendment and Rezoning Application: A request by
Benjamin Graff, on behalf of Quarles & Brady, LLP., for a Minor General Plan Amendment from PC
(Planned Commercial) to EMU (Entertainment Mixed Use) and a Rezoning application to amend the
existing Cornerstone at Camelback PAD (Planned Area Development). The site is located at the
northeast of and Camelback Road and 99th Avenue and is in the Yucca District.  Staff Contact:
Edward Vigil, Senior Planner, (623) 930-3071, evigil@glendaleaz.com 
REQUEST
1. Minor General Plan Amendment from PC (Planned Commercial) to EMU (Entertainment Mixed
Use).
2. Amend the existing Cornerstone at Camelback PAD (Planned Area Development).
APPLICANT/OWNER
Benjamin Graff representing Quarles & Brady, LLP. 
REQUIRED ACTION
The Planning Commission must conduct a public hearing and determine if this request is in the best
long-term interest of the neighborhood and consistent with the General Plan.
SUMMARY
The applicant is requesting a minor general plan amendment from PC (Planned Commercial) to
EMU (Entertainment Mixed Use) and to rezone the property to amend the existing PAD (Planned
Area Development) to create a multifamily mixed-use project with 3 buildings, 320 units, 4 stories tall
with a maximum height of 56 feet. The request includes:
A mixed-use multifamily development that will include retail on the first floor of buildings 1 & 2.
Create development standards for the multifamily with retail on the ground floor site only.
Increase the density for the multifamily site from 30 dwelling units per acre to 38 dwelling units
per acre.
Create sign criteria for the 3 multifamily buildings with retail on the ground floor of buildings 2
and 3 only. 
BACKGROUND INFORMATION

8/30/22, 9:22 AM
Print Agenda Item
https://destinyhosted.com/print_ag_memo.cfm?seq=7590&rev_num=0&mode=External&reloaded=true&id=45363
2/6
General Plan Designation:
The property land use designation is PC (Planned Commercial).
 
Zoning:
The property is currently zoned PAD (Cornerstone at Camelback-ZON05-04).
 
Property Location and Size:
The property is located at the northeast corner of 99th Avenue and Camelback Road and is
approximately 10.28 acres in size.
 
Project History:
The property was annexed into the City of Glendale on April 22, 2003, with annexation number
146.
The site was approved for a minor general plan amendment and rezoning in 2005 with cases
GPA05-04 & ZON05-04. 
The original zoning case was amended in 2018 to allow a self-storage land use, with case
ZON18-13. 
 Project Details:
The Cornerstone at Camelback PAD originally included approximately 18.23 acres when approved
in 2005.  In 2018, the PAD amended approximately 12.91 acres of the site to allow a self-storage
facility. The entire site currently allows several commercial zoning districts that allow land uses of
office, retail, hotel, restaurants, personal, financial, business services, medical and dental offices,
and self-storage. Currently, there is an existing hotel, bank, and restaurants to the east and south of
the PAD site. The self-storage building has been constructed and is to the north. Two existing pads
under control of the existing property owner, also exist within the site being amended and would be
developed with the already allowed uses and development standards.
 
The applicant is requesting to amend the existing PAD to include the multifamily land use with retail
on the ground floor and to create its own development standards. This mixed-use project will include
320 units in three buildings and four stories in height with a maximum height of 56 feet. The
proposed density is 38 dwelling units per acre and will offer both 1 and 2 bedrooms and provide a
total of 565 parking spaces. In addition to the 280,000 sq. ft. of multifamily, this development will
incorporate 7,070 sq. ft. of new ground floor commercial/retail uses integrated into the multifamily
buildings.
Amenities will include tuck under single car garages, clubhouse, a fitness area, a pool area, BBQ
stations, a putting green, fire pits, fireplaces, and an outdoor game area.
 
Additionally, the billboard existing at the northeast portion of the property will continue to operate and
will be maintained by existing ownership.
  
All other zoning land uses and development standards previously approved with cases ZON05-04
and ZON18-13 shall remain in effect.
 
The development standards proposed for the multifamily/retail site are listed below:
 
Development Standard
Proposed Development
Standard for
Multifamily/Retail Site
Number of Units
 
320
Density
 
38 dwelling units per acre.
Minimum Building
Setbacks
99TH Avenue
20 ft.

8/30/22, 9:22 AM
Print Agenda Item
https://destinyhosted.com/print_ag_memo.cfm?seq=7590&rev_num=0&mode=External&reloaded=true&id=45363
3/6
 
North
10 ft.
 
East
10 ft.
 
West
10 ft.
 
South
10 ft.
Open Space
Active Open Space
3%
 
Passive Open Space
20%
 
Total Open Space
23%
Minimum Landscape Area
& Setbacks
Total Site Area to be
Landscaped
15%
 
99TH Avenue
30 ft.
 
North
16 ft.
 
East
12 ft.
 
West
18 ft.
Parking
Parking Space Dimension
9 x 18
 
 
 
 
Off Street Parking Requirements by Use shall comply with requirements outlined within Section
7.403 of the City of Glendale Zoning Ordinance.
  
The development standards proposed for signs for the multifamily/retail mixed-use site are listed
below:
 
Wall Sign Standard Proposed:
 
Building 1
Building 2&3
Ground Floor Retail
on Building 2&3.
Number of Wall
Signs Allowed
1
2
2
Sign Letters
Length
Width
Height
 
3 inches
3 inches
2 inches
 
3 inches
3 inches
3 inches
 
6 inches
3 inches
1 foot 6 inches
Total Sign Area
39 square feet
63 square feet
9 square feet
Sign Height
32 feet
15 feet
10 feet
Sign Colors
See Exhibit H
 
 
Sign Materials
Aluminum
Aluminum
Aluminum
Sign Illumination
Illuminated
Illuminated
Illuminated
 
 
 
 
 
Any sign standard not stated in the table above shall be governed by Cases ZON05-04 and ZON18-
13.  Ground monument signs for multifamily residential, retail, or commercial uses are permitted and
shall comply with the above zoning cases or the City of Glendale Sign Code requirements.
  
NOTIFICATION:
 
Applicant’s Citizen Participation Process:
On June 7, 2022, the applicant mailed notification letters to adjacent property owners and interested
parties. The applicant did not receive any response regarding the request.  Planning did not receive
any response regarding the request either. The applicant’s Citizen Participation Final Report is
attached.
  
Planning Commission Public Hearing:

8/30/22, 9:22 AM
Print Agenda Item
https://destinyhosted.com/print_ag_memo.cfm?seq=7590&rev_num=0&mode=External&reloaded=true&id=45363
4/6
A Notice of Public Hearing was published in The Arizona Republic on August 3, 2022. Notification
postcards of the public hearing were mailed to adjacent property owners and interested parties on
August 5, 2022. The property was posted on August 5, 2022. 
STAFF FINDINGS AND ANALYSIS
Required Finding of Planning Commission:
 
Section 5.913 of the Zoning Ordinance requires the following finding to be met prior to approval of a
PAD (Planned Area Development) district:
 
The Planning Commission shall find that the PAD application is consistent with the purpose of the
district. The Commission evaluation shall include land use mixture, land use categories, land use
intensities, and the proposed development standards.  
 
Purpose:
 
Section 5.901 of the Zoning Ordinance states that the purpose of the PAD (Planned Area
Development) district is to:
 
A. Encourage creative and effective use of land and circulation systems to accommodate
changes in land development technologies.
Response: The proposed development utilizes a unique configuration of parcels to achieve an
integrated and seamless mixed-use development. Direct access to the proposed development will
be provided from several full access driveways located along the existing internal roadway network.
Right turn lanes and a two-way left-turn lane currently exist along 99th Avenue at each existing
shared access driveway to facilitate right and left turning movements for ingress and egress. The
proposed circulation will provide for a seamless environment for residents, pedestrians, and patrons
of the retails uses.
 
B. Encourage residential development to provide a mixture of housing types and designs.
Response: The proposed development seeks to integrate a high quality multifamily residential
development in addition to medical office, retail/commercial, and restaurant uses. The residential
development consists of higher end one- and two-bedroom units with a large number of amenities
and open space. The design of the buildings is contemporary in nature and seeks to promote a
dynamic layered look.
 
C. Encourage innovative development or redevelopment concepts for all land use types to
provide a greater variety and intensity of uses.
Response: The proposed development will feature a mixture of uses including the residential
component with ground floor retail. In addition, two pads will include land uses such as medical
office and retail. This provides a greater variety and intensity of uses throughout the overall PAD
area.
 
D. Provide a process which relates the urban design and scale of project to the unique
characteristics of the site.
 
Response: The urban design goal of the landscaping within the project is to provide residents and

8/30/22, 9:22 AM
Print Agenda Item
https://destinyhosted.com/print_ag_memo.cfm?seq=7590&rev_num=0&mode=External&reloaded=true&id=45363
5/6
visitors a sense of community with a strong sense of place. The architecture is contemporary with
undulating planes mixed with other earth-colored tones to give the facade a dynamically layered
look. The roofline is also articulated with various heights and finishes. Metal railings for the decks
and storefront glass for the retail component offer a stark contrast to the architectural planes. The
architectural theme of these three buildings is consistently maintained not only on the public facing
facades, but also on the internal courtyards and auto courts.
 
E. Require the nature and intensity of development to be supported by adequate utilities,
transportation, drainage, and common open spaces to serve the development and to minimize
impact on existing or future adjacent development.
 
Response: The proposed development is adequately supported by the current water and sewer
lines. All retention will be placed underground, and the development consists of 23.88% open space
for the enjoyment of residents.
 
F. Encourage development that is consistent with the policies and the guidelines established in
any specific plan and the General Plan.
 
Response: The proposed development is consistent with the requested Minor General Plan
Amendment, Western Area Plan and Airpark Character Area as described further in Section VIII.
  
Staff Findings:
The amendment is consistent with the policies and objectives of the Glendale General Plan,
the Western Area Plan, and the Cornerstone at Camelback PAD;
The amendment is compatible with other existing and planned development in the area;
The proposed amendment furthers the public health, safety and general welfare of the citizens
of Glendale; and
If the amendment is made to the official Zoning Map, the proposed change will include any
conditions necessary to mitigate any adverse impacts on the businesses, persons, or
properties adjacent to the requested amendment.
There are adequate school facilities.
Transportation and Land Development Engineering among other departments have all
reviewed and approved these applications.
RECOMMENDATION
Should the Planning Commission recommend approval of GPA22-02, it should be as written. 
 
Should the Planning Commission recommend approval of ZON22-10, it should be subject to the
stipulations in the staff report. 
 
PROPOSED MOTION
The Planning Commission should recommend approval of request GPA22-02, as written.
 
The Planning Commission should recommend approval of request ZON22-10, subject to the
following stipulations:

8/30/22, 9:22 AM
Print Agenda Item
https://destinyhosted.com/print_ag_memo.cfm?seq=7590&rev_num=0&mode=External&reloaded=true&id=45363
6/6
1. Development shall be in conformance with the revised PAD booklet entitled “Cornerstone at
Camelback,” dated July 28, 2022.
 
2. The north driveway along 99th Avenue shall be a right in right out driveway with a turn
restricting median.
 
3. Any proposed land uses and development changes not governed by this second PAD
amendment shall comply with the previously approved zoning cases ZON05-04 and ZON18-13
including the 19 stipulations approved by City Council on June 14, 2005. 
Attachments
PAD Narrative
Citizen Participation Plan Final Report
Prop 207 Waiver
TIA
Certificate of Adequate Schools
Certificate of Adequate Schools
Certificate of Adequate Schools
Certificate of Adequate Schools
General Plan Map
Zoning Map
Aerial Map
Presentation