Presentation

City of Glendale — Regular Meeting (2022-12-13)

View PDF Item 31 Meeting page

Extracted text (via pymupdf) 3324 characters
BETHANY HOME 303 PAD 
ZON22-14
City Council Voting Meeting– December 13, 2022

Request
2
1) Zone change from M-1 (Light Industrial) to PAD    
(Planned Area Development).
Applicant:  Michael Buschbacher on behalf of Earl 
& Curly, representing Mckinney Investment.

3
CITY 
HALL
SITE
Vicinity Map
Located south of the 
SEC of Bethany Home 
Road and Loop 303.

4
Aerial

5
Zoning Map

6
Conceptual Site Plan

7
Conceptual Landscape Plan

Proposed Development 
Standards:
8
DEVELOPMENT STANDARD
M-1 Standards
Proposed PAD 
Standards
Minimum Net Lot Area 
6,000 SF 
6,000 SF
Maximum Lot Area 
N/A
N/A
Building Setbacks 
Front Setback 
25-feet 
20-feet
Rear Setback 
60-feet2
60-feet2
Side Setback
60 feet2
60-feet2
Street Side Setback 
25-feet
25-feet
Landscape Setbacks 
Front 
20-feet 
15-feet 
Rear 
20-feet
10-feet
Street Side
20-feet 
20-feet 
West 
10-feet
10-feet 
1Sign area includes up to two (2) multi-tenant signs. 
260 feet to residential uses. 15 feet to non-residential uses. 
3The reduction in parking stall length will not include the overhang as part of the length (A parking stall 
cannot be striped at 16.5’ long with a 1.5’ overhang).

Proposed Development 
Standards:
9
1Sign area includes up to two (2) multi-tenant signs. 
260 feet to residential uses. 15 feet to non-residential uses. 
3The reduction in parking stall length will not include the overhang as part of the length (A parking stall 
cannot be striped at 16.5’ long with a 1.5’ overhang).  
DEVELOPMENT STANDARD
M-1 Standards
Proposed PAD Standards
Maximum Building Height 
30 feet
60 feet
Rooftop building appurtenances and 
material silos, or other similar building 
specific support elements can exceed 
roof height of 60 feet maximum 
provided they are more than 20 feet 
from the building’s roof edge and 
approved by LUKE AFB and the FAA. 
Roof mounted equipment shall be fully 
screened. 
Maximum FAR
0.3
.5 
(Mezzanine SF area excluded from FAR 
ratio)

Proposed Development 
Standards:
10
1Sign area includes up to two (2) multi-tenant signs. 
260 feet to residential uses. 15 feet to non-residential uses. 
3The reduction in parking stall length will not include the overhang as part of the length (A parking stall 
cannot be striped at 16.5’ long with a 1.5’ overhang).  
DEVELOPMENT STANDARD
M-1 Standards
Proposed PAD Standards
Auto Parking (Minimum Required) 

Warehouse, Distribution
& Data Center

Office/Medical

Commercial/Retail 
1/600 SF
1/300 SF
1/300 SF
1/2,000 SF
1/500 SF
1/500 SF
Parking Stall Dimensions
10’ x 20’
9’X18’3
Signage Height Standards
Freeway Pylon Sign
(Square Feet of Sign Area)
Multi-Tenant Pylon Signs 
(Square Feet of Sign Area)
Note: Two Signs are allowed per street frontage at a minimum 
separation of 330 feet. Existing Billboards will remain in place. 
N/A
10-feet 
Max. Height 50 feet 
450 SF1
30-feet
450 SF1

BETHANY HOME 303 PAD 
ZON22-14
City Council Voting Meeting– December 13, 2022

12
On November 10, 2022, Planning Commission  
recommend approval of ZON22-14, subject to 
the following stipulations:
Recommendation

Continued:
13
1.Development shall be in substantial conformance 
to the PAD Narrative entitled “Bethany Home 
303,” date stamped October 3, 2022.
2. An FAA form 7460-1 shall be submitted, 
reviewed and approved by the FAA prior to 
issuance of any building permits.