MATERIAL PRODUCT TRADENAME MODELNUMBER 2 AD FRONT LEFT RIGHT REAR 1 AD 11 AD 11 AD FLOOR PLAN A. INSULATION: R-38 BLOW-IN @ ATTIC - U.N.O ON PLAN R-13 BATTS @ EXT. 2X4 WALLS - U.N.O ON PLAN R-19 BATTS @ EXT. 2X6 WALLS - U.N.O ON PLAN B. PROVIDE R-13 BATT. (2X4 WALL) OR R-19 BATT (2X6 WALL) INSULATION BETWEEN GARAGE & ALL LIVABLE SPACES. C. ENVELOPED AREAS SHALL COMPLY WITH THE FOLLOWINGS: MAX U-FACTOR,0.40 MAX SHGC. MIN R-13 AT FRAME WALLS AND FLOORS R-6 @ MASS WALL, R-38 CEILINGS. DUCT INSULATION REQUIRES MINIMUM R-8 AND R-6 WHEN LOCATED IN FLOOR JOISTS. MINIMIZE AIR LEAKAGE. D. PROVIDE 5/8" TYPE 'X' GYPSUM BOARD ON WALLS & CEILING IN GARAGE & ON USABLE SPACE UNDER STAIRS PER CITY REQUIREMENTS. E. PROVIDE EXTERIOR TYPE GYP.BD. AT PATIO & PORCH CEILINGS - TAPE & TEXTURE. F. MAINTAIN A MAXIMUM HEIGHT OF 44" FROM FINISH FLOOR TO BOTTOM OF SILL - IN BEDROOM & BASEMENT EGRESS WINDOWS. - I.R.C SECTION R310.1 G. WHEN APPLYING WATHER-BASE TEXTURE MATERIAL, THEN MIN. GYP. BOARD THICKNESS SHALL BE INCEREASED FROM 3/8" TO 1/2" THICK FOR 16" O.C FRAMING AND FROM 1/2" TO 5/8 THICK FOR 24" O.C. FRAMING OR SAW RESISTANT GYP. BOARD SHALL BE USED - ESR #1338. H. GARAGE SHALL STEP AND/OR SLOPE TO -6" AT THE OVERHEAD GARAGE DOOR. I. GARAGE ENTRY DOORS TO BE 1 3 4" THICK SELF-CLOSING, SELF-LATCHING, SELF-SEALING DOOR W/ GASKET, THRESHOLD, SWEEP, SOLID CORE WOOD OR SOLID OR HONEY COMB STEEL DOOR OR 20 MINUTE FIRE RATED. J. ALL CLOSETS HAVE STANDARD 1 ROD AND 1 SHELF U.N.O. K. TUB/ SHOWER SURROUND SHALL BE INSTALLED OVER ONE LAYER OF DENSSHIELD OR APPROVED EQUAL. (CEMENT, FIBER CEMENT OR GLASS MAT GYP. BACKER W/ TILE, MARBLE OR EQ. TO +72" ABV. CURB OR DAM OF SHOWER -I.R.C. SEC R702.4.2) L. REFRIGERATOR SHALL BE PRE-PLUMBED FOR ICE-MAKER. M. ALL DOOR AND WINDOW GLAZING SHALL MEET THE REQUIREMENTS OF THE IRC, SECTION R308, WHETHER SPECIFICALLY IDENTIFIED ON THE PLANS OR NOT. N. WALL NICHE STANDARDS: -TOP OF NICHE TO BE PER PLAN, SOFFIT HEIGHT -BOTTOM OF NICHE TO BE +42" -WIDTH OF NICHE TO BE PER PLAN O. ALL EXTERIOR DOOR HEIGHTS TO BE 8'-0" TALL UNO ON PLAN. P. ALL INTERIOR DOORS TO BE 6'-8" TALL UNO ON PLAN. Q. EXTERIOR WINDOW HEADER HEIGHTS TO BE 8'-0" A.F.F. UNO ON PLAN. R. DIMENSIONS OF FLOOR PLAN(S) ARE SHOWN TO FACE OF STUD TYPICALLY UNLESS OTHERWISE NOTED. CONTRACTOR TO VERIFY ROUGH OPENING REQUIREMENTS OF ALL DOOR AND WINDOW UNITS PRIOR TO START OF CONSTRUCTION. S. CLOTHES DRYER EXHAUST DUCT REFER TO MECHANICAL PLAN. T. IF A POOL IS TO BE ADDED AT A LATER TIME; ALL DOORS AND WINDOWS ACCESSING THE POOL AREA MUST COMPLY WITH IRC AG 105.1 POOL BARRIERS - AMENDED; IRC R308.4 ITEM 9 AND; CITY OF GLENDALE POOL BARRIER ORDINANCE. U. NON-ABSORBENT SURFACE AT SHOWER/TUB TO AT LEAST SIX FEET ABOVE FINISHED FLOOR. (R307.2) 31 WASHER DRYER OPTIONAL UPPER CABINETS ABOVE WASHER/DRYER FLOOR PLAN NOTES DRYER EXHAUST DUCT POWER VENTILATOR SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURES INSTRUCTIONS. DRYER EXHAUST DUCT POWER VENTILATORS SHALL CONFORM TO UL 705 FOR USE IN DRYER EXHAUST DUCT SYSTEMS. THE MAXIMUM LENGTHT IS OF THE EXHAUST DUCT SHALL BE 35 FEET. DRYER EXHAUST TO CONFORM WITH TABLE M1502.4.5.1 CONSTRUCTION DOCUMENTS FOR A NEW CUSTOM HOME: GONZALEZ RESIDENCE 5303 W Beck Ln Glendale, AZ 85306 © Copyright Matrix Drafting & Design LLC 2020 1 A-1 1 2 3 4 5 6 7 8 8 8 9 10 10 10 10 11 12 7 13 14 15 15 16 17 18 22 23 23 23 23 24 24 25 25 26 25 26 26 26 27 32 28 20 32 KEY NOTES 1 2 3 4 CODE 5 REFRIGERATOR - PRE-PLUMB FOR ICE MAKER RANGE W/ HOOD- HOOD EXHAUST @ 77" 6 DOUBLE SINK W/ DISPOSAL TANKLESS WATER HEATHER W/ T&P LINE PER SPECS OR APPROVED EQUAL 7 1-3/4" THICK S.C. DOOR W/ CLOSURE, TIGHT FITTING GASKETS AND SWEEP. CEMENT,FIBER CEMENT OR GLASS MAT GYP. BACKER W/ TILE, MARBLE OR EQ. TO +72" ABV. CURB OR DAM OF SHOWER -I.R.C. SEC R702.4.2 WATER CLOSET PROVIDE A (MIN.) 15" ON EACH SIDE & 24" (MIN.) 8 9 10 11 12 13 14 15 16 17 CLEAR IN FRONT - I.R.C. SEC. R307 OPT. SINK ON LAUDRY MEDICINE CABINET-PER MANUFACTURERS SPECIFICATIONS GARAGE DOOR WITH GASKETS ALL AROUND AND GARAGE DOOR OPENER 24" TOWEL BAR AT +54" TYPICAL. PORCELAIN STEEL TUB/SHOWER COMBO. W/ ROD FOR SHOWER CURTAIN 18 19 20 GARAGE DOOR (OPEN POSITION) 1 ROD & 1 SHELF 22X30 ATTIC SCUTTLE-PROVIDE TYPE 'X' GYP. BD. @ GARAGE SIDE & 21 22 23 WEATHER STRIPPING - I.R.C. SEC. R807.1. SEE DETAIL 207/AD-1 COMPRESSOR PAD-ALTERNATE LOCATION IF SHOWN W/ DASHED LINES. VERIFY LOC. ON PLOT PLAN CONCRETE CURB LINE 24 25 26 (2) 14"X 8" COMB AIR VENTS, 12" ABV FLOOR & 12" BELOW CLG 27 WATER HEATER IS DIRECT VENT MIRROR STANDARD UPPER CABINETS. TOWEL RACK AT +64" PROVIDE NON-COMBUSTIBLE PLATFORM 32" SQ. X 18" ABOVE FINISH FLOOR FOR WATER HEATER WITH DRAIN PAN.@WH (P2801.5) 34 1/2" HIGH 2X6 KNEE WALL WITH COUNTERTOP STANDARD BASE CABINETS. NEW 200 AMP ELECTRICAL PANEL VANITY W/ SINK OR DOUBLE SINK 28 SLOPE CONCRETE AWAY FROM BUILDING 1/4" IN 12" MAXIMUM. NON-COMBUSTIBLE FLOOR SLOPED THROUGH A MAIN VEHICULAR ENTRY DOOR 29 ELECTRIC FIRE PLACE 25 24 8 10 12 7 15 26 25 24 8 10 12 7 15 26 25 24 SOFFIT AS NOTED 30 30 32 33 32 33 31 32 34 3" DIAMETER MIN. SOLID GROUTED STEEL POST GROUTED INTO CONCRETE ( EMBEDDED 2'-0" ) SEE DETAIL 14/AD Revised [23 JUN 2021] PLANNING DIVISION