VAR21-06 Floor Plan

City of Glendale — Regular Meeting (2021-10-14)

View PDF Item a Meeting page

Extracted text (via pymupdf) 5234 characters
MATERIAL
PRODUCT
TRADENAME
MODELNUMBER
2
AD
FRONT
LEFT
RIGHT
REAR
1
AD
11
AD
11
AD
FLOOR PLAN
A.
INSULATION:
R-38 BLOW-IN @ ATTIC      - U.N.O ON PLAN
R-13 BATTS @ EXT. 2X4 WALLS - U.N.O ON PLAN
R-19 BATTS @ EXT. 2X6 WALLS - U.N.O ON PLAN
B.
PROVIDE R-13 BATT. (2X4 WALL) OR R-19 BATT (2X6 WALL) INSULATION BETWEEN
GARAGE & ALL LIVABLE SPACES.
C.
ENVELOPED AREAS SHALL COMPLY WITH THE FOLLOWINGS:  MAX
U-FACTOR,0.40 MAX SHGC. MIN R-13 AT FRAME WALLS AND FLOORS R-6 @ MASS
WALL, R-38 CEILINGS. DUCT INSULATION  REQUIRES MINIMUM R-8 AND R-6 WHEN
LOCATED IN FLOOR JOISTS. MINIMIZE AIR LEAKAGE.
D.
PROVIDE 5/8" TYPE 'X' GYPSUM BOARD ON WALLS & CEILING IN GARAGE & ON
USABLE SPACE UNDER STAIRS PER CITY REQUIREMENTS.
E.
PROVIDE EXTERIOR TYPE GYP.BD. AT PATIO & PORCH CEILINGS - TAPE &
TEXTURE.
F.
MAINTAIN A MAXIMUM HEIGHT OF 44" FROM FINISH FLOOR TO BOTTOM OF SILL -
IN BEDROOM & BASEMENT EGRESS WINDOWS. - I.R.C SECTION R310.1
G.
WHEN APPLYING WATHER-BASE TEXTURE MATERIAL, THEN MIN. GYP. BOARD
THICKNESS SHALL BE INCEREASED FROM 3/8" TO 1/2" THICK FOR 16" O.C
FRAMING AND FROM 1/2" TO 5/8 THICK FOR 24" O.C. FRAMING OR SAW
RESISTANT GYP. BOARD SHALL BE USED - ESR #1338.
H.
GARAGE SHALL STEP AND/OR SLOPE TO -6" AT THE OVERHEAD GARAGE DOOR.
I.
GARAGE ENTRY DOORS TO BE 1 3
4" THICK SELF-CLOSING, SELF-LATCHING,
SELF-SEALING DOOR W/ GASKET, THRESHOLD, SWEEP, SOLID CORE WOOD OR
SOLID OR HONEY COMB STEEL DOOR OR 20 MINUTE FIRE RATED.
J.
ALL CLOSETS HAVE STANDARD 1 ROD AND 1 SHELF U.N.O.
K.
TUB/ SHOWER SURROUND SHALL BE INSTALLED OVER ONE LAYER OF
DENSSHIELD OR APPROVED EQUAL. (CEMENT, FIBER CEMENT OR GLASS MAT
GYP. BACKER W/ TILE, MARBLE  OR EQ. TO +72" ABV. CURB OR DAM OF SHOWER
-I.R.C. SEC R702.4.2)
L.
REFRIGERATOR SHALL BE PRE-PLUMBED FOR ICE-MAKER.
M.
ALL DOOR AND WINDOW GLAZING SHALL MEET THE REQUIREMENTS OF THE IRC,
SECTION R308, WHETHER SPECIFICALLY IDENTIFIED ON THE PLANS OR NOT.
N.
WALL NICHE STANDARDS:
-TOP OF NICHE TO BE PER PLAN, SOFFIT HEIGHT
-BOTTOM OF NICHE TO BE +42"
 
-WIDTH OF NICHE TO BE PER PLAN
O.
ALL EXTERIOR DOOR HEIGHTS TO BE 8'-0" TALL UNO ON PLAN.
P.
ALL INTERIOR DOORS TO BE 6'-8" TALL UNO ON PLAN.
Q.
EXTERIOR WINDOW HEADER HEIGHTS TO BE 8'-0" A.F.F. UNO ON PLAN.
R.
DIMENSIONS OF FLOOR PLAN(S) ARE SHOWN TO FACE OF STUD TYPICALLY
UNLESS OTHERWISE NOTED. CONTRACTOR TO VERIFY ROUGH OPENING
REQUIREMENTS OF ALL DOOR AND WINDOW UNITS PRIOR TO START OF
CONSTRUCTION.
S.
CLOTHES DRYER EXHAUST DUCT REFER TO MECHANICAL PLAN.
T.
IF A POOL IS TO BE ADDED AT A LATER TIME; ALL DOORS AND WINDOWS
ACCESSING THE POOL AREA MUST COMPLY WITH IRC AG 105.1 POOL BARRIERS -
AMENDED; IRC R308.4 ITEM 9 AND; CITY OF GLENDALE POOL BARRIER
ORDINANCE.
U.
NON-ABSORBENT SURFACE AT SHOWER/TUB TO AT LEAST SIX FEET ABOVE
FINISHED FLOOR. (R307.2)
31
WASHER 
DRYER 
OPTIONAL UPPER CABINETS ABOVE WASHER/DRYER 
FLOOR PLAN NOTES
DRYER EXHAUST DUCT POWER VENTILATOR SHALL BE INSTALLED IN ACCORDANCE WITH 
MANUFACTURES INSTRUCTIONS. DRYER EXHAUST DUCT POWER VENTILATORS SHALL
CONFORM TO UL 705 FOR USE IN DRYER EXHAUST DUCT SYSTEMS. THE MAXIMUM 
LENGTHT IS OF THE EXHAUST DUCT SHALL BE 35 FEET.  DRYER EXHAUST TO CONFORM 
WITH TABLE M1502.4.5.1
CONSTRUCTION DOCUMENTS FOR A NEW CUSTOM HOME:
GONZALEZ RESIDENCE
5303 W Beck Ln Glendale, AZ 85306
© Copyright Matrix Drafting & Design LLC 2020
1
A-1
1
2
3
4
5
6
7
8
8
8
9
10
10
10
10
11
12
7
13
14
15
15
16
17
18
22
23
23
23
23
24
24
25
25
26
25
26
26
26
27
32
28
20
32
KEY NOTES
1
2
3
4
CODE
5
REFRIGERATOR - PRE-PLUMB FOR ICE MAKER 
RANGE W/ HOOD- HOOD EXHAUST @ 77"  
6
DOUBLE SINK W/ DISPOSAL 
 TANKLESS WATER HEATHER W/ T&P LINE PER SPECS OR APPROVED EQUAL 
7
1-3/4" THICK S.C. DOOR W/ CLOSURE, TIGHT FITTING GASKETS AND SWEEP. 
CEMENT,FIBER CEMENT OR GLASS MAT GYP. BACKER W/ TILE, MARBLE  OR EQ.  
TO +72" ABV. CURB OR DAM OF SHOWER -I.R.C. SEC R702.4.2
WATER CLOSET PROVIDE A (MIN.) 15" ON EACH SIDE & 24" (MIN.)  
8
9
10
11
12
13
14
15
16
17
CLEAR IN FRONT - I.R.C. SEC. R307 
OPT. SINK ON LAUDRY
MEDICINE CABINET-PER MANUFACTURERS SPECIFICATIONS 
GARAGE DOOR WITH GASKETS ALL AROUND AND GARAGE DOOR OPENER 
24" TOWEL BAR AT +54" TYPICAL. 
PORCELAIN STEEL TUB/SHOWER COMBO. W/ ROD FOR SHOWER CURTAIN 
18
19
20
GARAGE DOOR (OPEN POSITION) 
1 ROD & 1 SHELF 
22X30 ATTIC SCUTTLE-PROVIDE TYPE 'X' GYP. BD. @ GARAGE SIDE & 
21
22
23
 WEATHER STRIPPING - I.R.C. SEC. R807.1. SEE DETAIL 207/AD-1  
COMPRESSOR PAD-ALTERNATE LOCATION IF SHOWN W/ DASHED LINES. 
VERIFY LOC. ON PLOT PLAN  
CONCRETE CURB LINE 
24
25
26
(2) 14"X 8" COMB AIR VENTS, 12" ABV FLOOR & 12" BELOW CLG 
27
WATER HEATER IS DIRECT VENT
MIRROR
STANDARD UPPER CABINETS. 
TOWEL RACK AT +64" 
PROVIDE NON-COMBUSTIBLE PLATFORM 32" SQ. X  18" ABOVE FINISH FLOOR FOR WATER  
HEATER WITH DRAIN PAN.@WH (P2801.5)
34 1/2" HIGH 2X6 KNEE WALL WITH COUNTERTOP
STANDARD BASE CABINETS.
NEW 200 AMP ELECTRICAL PANEL
VANITY W/ SINK OR DOUBLE SINK
28
SLOPE CONCRETE AWAY FROM BUILDING 1/4" IN 12"  MAXIMUM. 
NON-COMBUSTIBLE FLOOR SLOPED THROUGH A MAIN VEHICULAR ENTRY DOOR
29
ELECTRIC FIRE PLACE
25
24
8
10
12
7
15
26
25
24
8
10
12
7
15
26
25
24
SOFFIT AS NOTED
30
30
32
33
32
33
31
32
34
3" DIAMETER MIN. SOLID GROUTED STEEL POST GROUTED INTO CONCRETE
( EMBEDDED 2'-0" )  SEE DETAIL 14/AD
Revised
[23 JUN 2021]
PLANNING DIVISION