Site Plan

City of Glendale — Regular Meeting (2023-12-14)

View PDF Item a Meeting page

Extracted text (via pymupdf) 4830 characters
ALLEY
CL
CL
CL
1
SQFT= 2,700
SQFT= 22
4
SQFT= 327
2
SQFT= 392
3
WM
WL
WL
WL
WL
EXISTING 6' HIGH BLOCK WALL
EXISTING 6' HIGH BLOCK WALL
EXISTING 6' HIGH BLOCK WALL
200 AMP
OHE
OHE
SL
SL
SL
SL
SL
SL
SL
PROPOSED CONCRETE
DRIVEWAY
17'-0" X 20'-0"
X
X
X
5
X
X
X
X
X
X
X
X
X
X
5
6
7
6
6
ONE LINE DIAGRAM 
M
E3604.2.1 ABOVE ROOFS.- CONDUCTORS SHALL
HAVE A VERTICAL CLEARANCE OF NOT LESS THAN 8
FEET (2438 MM) ABOVE THE ROOF SURFACE. THE
VERTICAL CLEARANCE ABOVE THE ROOF LEVEL
SHALL BE MAINTAINED FOR A DISTANCE OF NOT
LESS THAN 3 FEET (914 MM) IN ALL DIRECTIONS
FROM THE EDGE OF THE ROOF. SEE FIGURE
E3604.2.1. [2017 NEC 230.24(A)]
E3604.2.2 VERTICAL CLEARANCE FROM GRADE.-
OVERHEAD SERVICE CONDUCTORS SHALL HAVE THE
FOLLOWING MINIMUM CLEARANCES FROM FINAL
GRADE:
1.
FOR CONDUCTORS SUPPORTED ON AND
CABLED TOGETHER WITH A GROUNDED BARE
MESSENGER 
WIRE, 
THE 
MINIMUM 
VERTICAL
CLEARANCE SHALL BE 10 FEET (3048 MM) AT THE
ELECTRIC SERVICE ENTRANCE TO BUILDINGS, AT
THE LOWEST POINT OF THE DRIP LOOP OF THE
BUILDING ELECTRIC ENTRANCE, AND ABOVE AREAS
OR SIDEWALKS ACCESSED BY PEDESTRIANS ONLY.
SUCH CLEARANCE SHALL BE MEASURED FROM FINAL
GRADE OR OTHER ACCESSIBLE SURFACES.
2.
TWELVE 
FEET 
(3658 
MM)—OVER
RESIDENTIAL PROPERTY AND DRIVEWAYS.
3.
EIGHTEEN FEET (5486 MM)—OVER PUBLIC
STREETS, ALLEYS, ROADS OR PARKING AREAS
SUBJECT 
TO 
TRUCK 
TRAFFIC. 
[2017 
NEC
(230.24(B)(1), (2), AND (4)]
(SEE SPECIFIC SITE PLAN FOR LOCATION AND OWNER/DEVELOPER TO  CHOOSE WHICH DIAGRAM TO FOLLOW)
1
2
3
5
7
6
7
3
1
2
8
4
5
6
TYP FOUNDATION FOR CMU WALL
TYP GATE CONECTOR AT CMU WALL
A0
KEY NOTES
NEW MAIN HOUSE (LIVABLE)
SIDE PATIO (NOT LIVABLE)
1
2
4
2 CAR GARAGE (NOT LIVABLE)
3
FRONT PORCH (NOT LIVABLE)
NOTE:
6609 N 54TH DR GLENDALE, AZ 85301
R-3
GLENDALE
8 2N 2E
22
146-08-051
1940
PROJECT INFORMATION
OWNER
PROJECT ADDRESS:
ZONING:
JURISDICTION:
SECTION T.R.:
LOT.:
PARCEL #:
CONSTRUCTION YEAR:
ESTRADA MARGARITA GARCIA
PROJECT DESCRIPTION
AREAS
TOTAL AREAS
VICINITY MAP
MAIN HOUSE (LIVABLE)
2700
  SQ. FT.
SIDE PATIO (NON LIVABLE)
327
  SQ. FT.
2 CAR GARAGE (NON LIVABLE)
392
  SQ. FT.
FRONT PORCH (NON LIVABLE)
22
  SQ. FT.
LIVABLE
2,700
  SQ. FT.
NON LIVABLE
741
  SQ. FT.
TOTAL
3441
  SQ. FT.
LOT SIZE
7,000
  SQ. FT.
LOT COVERAGE
49.1600
  %
MAX LOT COVERAGE
50   %
PROPERTY LINE.
CENTRAL LINE
SET BACK LINE.
OVERHANG
WATER LINE
SEWER LINE
WL
SL
EXISTING SIDEWALK
S/W
RIGHT OF WAY
R/W.
PUBLIC UTILITY EASEMENT
P.U.E.
BUILDING SETBACK LINE
B.S.L.
FINISH FLOOR ELEVATION
F.F.E.
(NOT ALL USED)
WM
OVERHANG ELECTRIC
OHE
WATER METER
UNDERGROUND ELECTRIC
UGE
CONCRETE DRIVEWAY.
GAS LINE
G
FIBER CABLE
F0
LEGEND
PL
SL
CL
ELECTRIC CONTROL VALVE SIZE AS SHOWN. SEE DETAIL 601
ISOLATION VALVE LINE SIZED. SEE DETAIL 603
SLEEVING LINE
WATER LINE 1
2"
EMITTER ON STAKER. SEE DETAIL 602
CONTROLLER PLASTIC WALL MOUNT. SEE DETAIL 600
HUNTER 17 MM BLANK PLT TUBING
NEW CONCRETE SLAB
NEW CONCRETE DRIVEWAY
PROPERTY LINE DIMENSIONS ON SITE PLAN  ARE OBTAINED FROM COUNTY ASSESSOR'S
WEBSITE AND ARE TO BE USED AS A POINT OF REFERENCE ONLY. FOR EXACT DIMENSIONS,
PLEASE CONTACT A REGISTERED SURVEYOR.  ARQM Architect SHOULD NOT BE HELD LIABLE
IF THE DIMENSIONS FOUND ON COUNTY ASSESSOR'S WEBSITE ARE INACCURATE, IT IS THE
RESPONSIBILITY OF THE OWNER/CONTRACTOR TO GET A SURVEY OF THE PROPERTY.
CONTRACTOR MUST VERIFY THAT THE FINNISH FLOOR OF THE NEW BUILDING MUST BE AT
LEAST 14" UP FROM THE LOW PART OF THE EXISTING TOP OF CURB.
Contact Arizona 811 at least two full
working days before you begin excavation
CALL 811 or click Arizona811.COM
A.
ANY BROKEN CONCRETE ADJACENT TO THE NEW DRIVEWAY ENTRANCE SHALL BE
REMOVED AND REPLACED PRIOR TO THE CERTIFICATE OF OCCUPANCY BEING
ISSUED.
B.
ANY CONCRETE IN THE RIGHT-OF-WAY BROKEN DURING CONSTRUCTION SHALL BE
REMOVED AND REPLACED PRIOR TO THE CERTIFICATE OF OCCUPANCY BEING
ISSUED.
C.
CONTRACTOR TO LOCATE UTILITY SERVICES PRIOR TO CONSTRUCTION.
D.
WATER AND SEWER SERVICE LOCATIONS AND CONDITIONS SHALL BE FIELD
VERIFIED. BASED ON THE CONDITION, SERVICES MAY BE REQUIRED TO BE REMOVED
AND REPLACED BY OWNER.
NOTES:
N
NEW 2821 SQ. FT. LIVABLE CUSTOM RESIDENCE WITH A 2
CAR GARAGE AND FRONT PORCH AND PATIO
PAD NOTE:
DRIVEWAY NOTE:
EXISTING DRIVEWAY ENTRANCE SHALL BE REMOVED AND REPLACED WITH SIDEWALK,
CURB AND GUTTER.
0
10'
20'
Scale:
1
SITE PLAN
1"=10'-0"
5
CHAIN LINK FENCE TO BE REMOVED
6
NEW 3'-6" CMU WALL 20 L.F
7
NEW 6' CMU WALL 120 L.F
S+EET:
SCALE:
DATE:
ARQM ARCHITECT
C+ECKED %Y:
ESLY VILLAR
DRAWN %Y:
(623)  853 3751
CONTACT:
ARQM 
LLC 
RZQV 
GHVLJQV,
FRQFHSWV,   LQIRUPDWLRQ   GDWD,
DQG  GHWDLOV FRQWDLQHG  LQ WKHVH
GUDZLQJV,  WKH\  FRXOG  UHIHU  WR
EUDQGV           RQO\              DV
FRPSOHPHQWDU\    LQIRUPDWLRQ
FDQQRW   EH   XVHG    E\   RWKHUV
ZLWKRXW    D  ZULWWHQ  DSSURYDO
VLJQHG  Ey   ARQM  LLC.
No.
Revisions
Date
6609 N 54TH DR
GLENDALE, AZ 85301
PER PLAN
ARQM LLC
CITY COMMENTS
1