ALLEY CL CL CL 1 SQFT= 2,700 SQFT= 22 4 SQFT= 327 2 SQFT= 392 3 WM WL WL WL WL EXISTING 6' HIGH BLOCK WALL EXISTING 6' HIGH BLOCK WALL EXISTING 6' HIGH BLOCK WALL 200 AMP OHE OHE SL SL SL SL SL SL SL PROPOSED CONCRETE DRIVEWAY 17'-0" X 20'-0" X X X 5 X X X X X X X X X X 5 6 7 6 6 ONE LINE DIAGRAM M E3604.2.1 ABOVE ROOFS.- CONDUCTORS SHALL HAVE A VERTICAL CLEARANCE OF NOT LESS THAN 8 FEET (2438 MM) ABOVE THE ROOF SURFACE. THE VERTICAL CLEARANCE ABOVE THE ROOF LEVEL SHALL BE MAINTAINED FOR A DISTANCE OF NOT LESS THAN 3 FEET (914 MM) IN ALL DIRECTIONS FROM THE EDGE OF THE ROOF. SEE FIGURE E3604.2.1. [2017 NEC 230.24(A)] E3604.2.2 VERTICAL CLEARANCE FROM GRADE.- OVERHEAD SERVICE CONDUCTORS SHALL HAVE THE FOLLOWING MINIMUM CLEARANCES FROM FINAL GRADE: 1. FOR CONDUCTORS SUPPORTED ON AND CABLED TOGETHER WITH A GROUNDED BARE MESSENGER WIRE, THE MINIMUM VERTICAL CLEARANCE SHALL BE 10 FEET (3048 MM) AT THE ELECTRIC SERVICE ENTRANCE TO BUILDINGS, AT THE LOWEST POINT OF THE DRIP LOOP OF THE BUILDING ELECTRIC ENTRANCE, AND ABOVE AREAS OR SIDEWALKS ACCESSED BY PEDESTRIANS ONLY. SUCH CLEARANCE SHALL BE MEASURED FROM FINAL GRADE OR OTHER ACCESSIBLE SURFACES. 2. TWELVE FEET (3658 MM)—OVER RESIDENTIAL PROPERTY AND DRIVEWAYS. 3. EIGHTEEN FEET (5486 MM)—OVER PUBLIC STREETS, ALLEYS, ROADS OR PARKING AREAS SUBJECT TO TRUCK TRAFFIC. [2017 NEC (230.24(B)(1), (2), AND (4)] (SEE SPECIFIC SITE PLAN FOR LOCATION AND OWNER/DEVELOPER TO CHOOSE WHICH DIAGRAM TO FOLLOW) 1 2 3 5 7 6 7 3 1 2 8 4 5 6 TYP FOUNDATION FOR CMU WALL TYP GATE CONECTOR AT CMU WALL A0 KEY NOTES NEW MAIN HOUSE (LIVABLE) SIDE PATIO (NOT LIVABLE) 1 2 4 2 CAR GARAGE (NOT LIVABLE) 3 FRONT PORCH (NOT LIVABLE) NOTE: 6609 N 54TH DR GLENDALE, AZ 85301 R-3 GLENDALE 8 2N 2E 22 146-08-051 1940 PROJECT INFORMATION OWNER PROJECT ADDRESS: ZONING: JURISDICTION: SECTION T.R.: LOT.: PARCEL #: CONSTRUCTION YEAR: ESTRADA MARGARITA GARCIA PROJECT DESCRIPTION AREAS TOTAL AREAS VICINITY MAP MAIN HOUSE (LIVABLE) 2700 SQ. FT. SIDE PATIO (NON LIVABLE) 327 SQ. FT. 2 CAR GARAGE (NON LIVABLE) 392 SQ. FT. FRONT PORCH (NON LIVABLE) 22 SQ. FT. LIVABLE 2,700 SQ. FT. NON LIVABLE 741 SQ. FT. TOTAL 3441 SQ. FT. LOT SIZE 7,000 SQ. FT. LOT COVERAGE 49.1600 % MAX LOT COVERAGE 50 % PROPERTY LINE. CENTRAL LINE SET BACK LINE. OVERHANG WATER LINE SEWER LINE WL SL EXISTING SIDEWALK S/W RIGHT OF WAY R/W. PUBLIC UTILITY EASEMENT P.U.E. BUILDING SETBACK LINE B.S.L. FINISH FLOOR ELEVATION F.F.E. (NOT ALL USED) WM OVERHANG ELECTRIC OHE WATER METER UNDERGROUND ELECTRIC UGE CONCRETE DRIVEWAY. GAS LINE G FIBER CABLE F0 LEGEND PL SL CL ELECTRIC CONTROL VALVE SIZE AS SHOWN. SEE DETAIL 601 ISOLATION VALVE LINE SIZED. SEE DETAIL 603 SLEEVING LINE WATER LINE 1 2" EMITTER ON STAKER. SEE DETAIL 602 CONTROLLER PLASTIC WALL MOUNT. SEE DETAIL 600 HUNTER 17 MM BLANK PLT TUBING NEW CONCRETE SLAB NEW CONCRETE DRIVEWAY PROPERTY LINE DIMENSIONS ON SITE PLAN ARE OBTAINED FROM COUNTY ASSESSOR'S WEBSITE AND ARE TO BE USED AS A POINT OF REFERENCE ONLY. FOR EXACT DIMENSIONS, PLEASE CONTACT A REGISTERED SURVEYOR. ARQM Architect SHOULD NOT BE HELD LIABLE IF THE DIMENSIONS FOUND ON COUNTY ASSESSOR'S WEBSITE ARE INACCURATE, IT IS THE RESPONSIBILITY OF THE OWNER/CONTRACTOR TO GET A SURVEY OF THE PROPERTY. CONTRACTOR MUST VERIFY THAT THE FINNISH FLOOR OF THE NEW BUILDING MUST BE AT LEAST 14" UP FROM THE LOW PART OF THE EXISTING TOP OF CURB. Contact Arizona 811 at least two full working days before you begin excavation CALL 811 or click Arizona811.COM A. ANY BROKEN CONCRETE ADJACENT TO THE NEW DRIVEWAY ENTRANCE SHALL BE REMOVED AND REPLACED PRIOR TO THE CERTIFICATE OF OCCUPANCY BEING ISSUED. B. ANY CONCRETE IN THE RIGHT-OF-WAY BROKEN DURING CONSTRUCTION SHALL BE REMOVED AND REPLACED PRIOR TO THE CERTIFICATE OF OCCUPANCY BEING ISSUED. C. CONTRACTOR TO LOCATE UTILITY SERVICES PRIOR TO CONSTRUCTION. D. WATER AND SEWER SERVICE LOCATIONS AND CONDITIONS SHALL BE FIELD VERIFIED. BASED ON THE CONDITION, SERVICES MAY BE REQUIRED TO BE REMOVED AND REPLACED BY OWNER. NOTES: N NEW 2821 SQ. FT. LIVABLE CUSTOM RESIDENCE WITH A 2 CAR GARAGE AND FRONT PORCH AND PATIO PAD NOTE: DRIVEWAY NOTE: EXISTING DRIVEWAY ENTRANCE SHALL BE REMOVED AND REPLACED WITH SIDEWALK, CURB AND GUTTER. 0 10' 20' Scale: 1 SITE PLAN 1"=10'-0" 5 CHAIN LINK FENCE TO BE REMOVED 6 NEW 3'-6" CMU WALL 20 L.F 7 NEW 6' CMU WALL 120 L.F S+EET: SCALE: DATE: ARQM ARCHITECT C+ECKED %Y: ESLY VILLAR DRAWN %Y: (623) 853 3751 CONTACT: ARQM LLC RZQV GHVLJQV, FRQFHSWV, LQIRUPDWLRQ GDWD, DQG GHWDLOV FRQWDLQHG LQ WKHVH GUDZLQJV, WKH\ FRXOG UHIHU WR EUDQGV RQO\ DV FRPSOHPHQWDU\ LQIRUPDWLRQ FDQQRW EH XVHG E\ RWKHUV ZLWKRXW D ZULWWHQ DSSURYDO VLJQHG Ey ARQM LLC. No. Revisions Date 6609 N 54TH DR GLENDALE, AZ 85301 PER PLAN ARQM LLC CITY COMMENTS 1