CP Final Report without Labels

City of Glendale — Regular Meeting (2023-12-14)

View PDF Item a Meeting page

Extracted text (via pymupdf) 7788 characters
9 
COMPLETION OF THE FOLLOWING IS NECESSARY FOR FINAL REPORT APPROVAL. 
 
SUMMARY / FINAL 
REPORT 
Total individuals 
notified: 
 
Total Participants:  
CONCERNS, ISSUES, PROBLEMS EXPRESSED 
 
 
 
 
 
HOW CONCERNS WILL BE ADDRESSED? 
 
 
 
 
 
CONCERNS APPLICANT IS UNWILLING TO ADDRESS 
 
 
 
 
 
HOW THE PROPOSAL HAS BEEN REVISED TO ADDRESS 
CONCERNS 
 
 
 
 
 
APPLICANT SIGNATURE AND DATE 
 
 
 
REQUIRED ATTACHMENTS: 
 NOTIFICATION AREA MAP 
 NOTIFICATION LETTER AND SITE PLAN 
Failed
BY
DATE
Conditionally Approved
Approved

Sydney Tirella
11/13/2023
City of Glendale
Development Services Department
Planning Division
VAR23-06 Final CPP Report and attachments

9/15/23 
 Arqm LLC 
 6501 N Black Canyon Hwy 
 Phoenix, AZ 85015 
 Arqmarchitect@outlook.com 
 (623)  853-3751 
 Subject: Property at 6609 N 54th Dr, Glendale, AZ 85301 
 Dear Neighbor: 
 This  letter  is  to  inform  you  that  I  am  applying  for  a  variance  application  with  the  City  of  Glendale. 
 The property is located at  6609 N 54th Dr, Glendale, AZ 85301  in the Ocotillo District. 
 The  project  has  an  area  of  3,458  sq.  ft,  with  a  gross  lot  size  of  7,000  sq.  ft.  The  setbacks  for  the 
 proposed  structure  will  be  front:  20’,  rear:  20’,  north  side:  7’  and  south  side:  8’.  The  building  will 
 be  at  the  maximum—permitted  building  height  in  the  City  of  Glendale.  Property  zoning  is  R-3, 
 and  surrounding  properties  are  also  under  the  same  zoning.  The  side  setbacks  imposed  by  the 
 zoning  ordinance  for  R-3  present  significant  limitations  that  hinder  the  feasibility  of  constructing 
 a reasonable building on the property. 
 I  have  included  a  site  plan  with  this  letter  for  your  review.  A  neighborhood  virtual  meeting  will 
 occur  on  Friday,  September  29,  2023,  at  7:00  p.m.  on  Zoom  (meeting  ID:  848  785  5627).  If 
 prompted,  passcode:  Glendale .  Comments  and  questions  will  be  accepted  at  this  time,  until 
 September  29,  2023.  If  you  cannot  attend,  please  write,  email,  or  call  me  at  the  contact 
 information  above  or  at  wendyj_arqmllc@outlook.com  for  a  quicker  response.  You  may  also 
 contact  Sydney  Tirella  with  the  City  of  Glendale  at  (623)  930-2588  or  email  at 
 STirella@glendaleaz.com. 
 Sincerely, 
 Wendy Jimenez 
 Arqm LLC 
 Encl: Site Plan 
Failed
BY
DATE
Conditionally Approved
Approved

Sydney Tirella
9/14/2023
City of Glendale
Development Services Department
Planning Division
Approved Notification Letter for VAR23-06

1 
 
NEIGHBORHOOD NOTIFICATION AREA 
NAME OF REQUEST: 
SR23-0342 6609 N 54TH DR VARIANCE 
LOCATION: 
6609 N 54TH DR 
REQUEST: 
The applicant is requesting Board of Adjustment approval for 
a Variance to reduce minimum side setbacks from 20 feet to 
7 feet along the north property line and 8 feet along the south 
property line for a residential addition. 
ZONING DISTRICT: R-3 
COUNCIL DISTRICT: Ocotillo 
FORMAL APPLICATION 
SUBMITTED:  No 
EMAIL ADDRESS: wendyj_armqllc@outlook.com 
 
NOTIFICATION AREA 
PROPERTY

ALLEY
CL
CL
CL
1
SQFT= 2821
SQFT= 24
4
SQFT= 227
2
SQFT= 386
3
WM
WL
WL
WL
WL
(E)6' HIGH BLOCK WALL
(E)6' HIGH BLOCK WALL
(E)6' HIGH BLOCK WALL
200 AMP
OHE
OHE
SL
SL
SL
SL
SL
SL
SL
ONE LINE DIAGRAM 
M
E3604.2.1 ABOVE ROOFS.- CONDUCTORS SHALL
HAVE A VERTICAL CLEARANCE OF NOT LESS THAN 8
FEET (2438 MM) ABOVE THE ROOF SURFACE. THE
VERTICAL CLEARANCE ABOVE THE ROOF LEVEL
SHALL BE MAINTAINED FOR A DISTANCE OF NOT
LESS THAN 3 FEET (914 MM) IN ALL DIRECTIONS
FROM THE EDGE OF THE ROOF. SEE FIGURE
E3604.2.1. [2017 NEC 230.24(A)]
E3604.2.2 VERTICAL CLEARANCE FROM GRADE.-
OVERHEAD SERVICE CONDUCTORS SHALL HAVE THE
FOLLOWING MINIMUM CLEARANCES FROM FINAL
GRADE:
1.
FOR CONDUCTORS SUPPORTED ON AND
CABLED TOGETHER WITH A GROUNDED BARE
MESSENGER 
WIRE, 
THE 
MINIMUM 
VERTICAL
CLEARANCE SHALL BE 10 FEET (3048 MM) AT THE
ELECTRIC SERVICE ENTRANCE TO BUILDINGS, AT
THE LOWEST POINT OF THE DRIP LOOP OF THE
BUILDING ELECTRIC ENTRANCE, AND ABOVE AREAS
OR SIDEWALKS ACCESSED BY PEDESTRIANS ONLY.
SUCH CLEARANCE SHALL BE MEASURED FROM FINAL
GRADE OR OTHER ACCESSIBLE SURFACES.
2.
TWELVE 
FEET 
(3658 
MM)—OVER
RESIDENTIAL PROPERTY AND DRIVEWAYS.
3.
EIGHTEEN FEET (5486 MM)—OVER PUBLIC
STREETS, ALLEYS, ROADS OR PARKING AREAS
SUBJECT 
TO 
TRUCK 
TRAFFIC. 
[2017 
NEC
(230.24(B)(1), (2), AND (4)]
(SEE SPECIFIC SITE PLAN FOR LOCATION AND OWNER/DEVELOPER TO  CHOOSE WHICH DIAGRAM TO FOLLOW)
1
2
3
5
7
6
7
3
1
2
8
4
5
6
TYP FOUNDATION FOR CMU WALL
TYP GATE CONECTOR AT CMU WALL
A0
SHEET:
SCALE:
DATE:
ARQM ARCHITECT
CHECKED BY:
ESLY VILLAR
DRAWN BY:
(623)  853 3751
CONTACT:
ARQM 
LLC 
RZQV 
GHVLJQV,
FRQFHSWV,   LQIRUPDWLRQ   GDWD,
DQG  GHWDLOV FRQWDLQHG  LQ WKHVH
GUDZLQJV,  WKH\  FRXOG  UHIHU  WR
EUDQGV           RQO\              DV
FRPSOHPHQWDU\    LQIRUPDWLRQ
FDQQRW   EH   XVHG    E\   RWKHUV
ZLWKRXW    D  ZULWWHQ  DSSURYDO
VLJQHG  Ey   ARQM  LLC.
No.
Revisions
Date
6609 N 54TH DR
GLENDALE, AZ 85301
PER PLAN
ARQM LLC
CITY COMMENTS
1
KEY NOTES
NEW MAIN HOUSE (LIVABLE)
SIDE PATIO (NOT LIVABLE)
1
2
4
2 CAR GARAGE (NOT LIVABLE)
3
FRONT PORCH (NOT LIVABLE)
NOTE:
6609 N 54TH DR GLENDALE, AZ 85301
R-3
GLENDALE
8 2N 2E
22
146-08-051
1940
3RO-ECT ,N)OR0AT,ON
OWNER
PROJECT ADDRESS:
ZONING:
JURISDICTION:
SECTION T.R.:
LOT.:
PARCEL #:
CONSTRUCTION YEAR:
ESTRADA MARGARITA GARCIA
3RO-ECT DESCR,3T,ON
AREAS
TOTAL AREAS
9,C,N,TY 0A3
MAIN HOUSE (LIVABLE)
2821
  SQ. FT.
SIDE PATIO (NON LIVABLE)
227
  SQ. FT.
2 CAR GARAGE (NON LIVABLE)
386
  SQ. FT.
FRONT PORCH (NON LIVABLE)
24
  SQ. FT.
LIVABLE
2,821
  SQ. FT.
NON LIVABLE
637
  SQ. FT.
TOTAL
3458
  SQ. FT.
LOT SIZE
7,000
  SQ. FT.
LOT COVERAGE
49.4000
  %
MAX LOT COVERAGE
50   %
PROPERTY LINE.
CENTRAL LINE
SET BACK LINE.
OVERHANG
WATER LINE
SEWER LINE
WL
SL
EXISTING SIDEWALK
S/W
RIGHT OF WAY
R/W.
PUBLIC UTILITY EASEMENT
P.U.E.
BUILDING SETBACK LINE
B.S.L.
FINISH FLOOR ELEVATION
F.F.E.
(NOT ALL USED)
WM
OVERHANG ELECTRIC
OHE
WATER METER
UNDERGROUND ELECTRIC
UGE
CONCRETE DRIVEWAY.
GAS LINE
G
FIBER CABLE
F0
LE*END
PL
SL
CL
ELECTRIC CONTROL VALVE SIZE AS SHOWN. SEE DETAIL 601
ISOLATION VALVE LINE SIZED. SEE DETAIL 603
SLEEVING LINE
WATER LINE 1
2"
EMITTER ON STAKER. SEE DETAIL 602
CONTROLLER PLASTIC WALL MOUNT. SEE DETAIL 600
HUNTER 17 MM BLANK PLT TUBING
NEW CONCRETE SLAB
NEW CONCRETE DRIVEWAY
PROPERTY LINE DIMENSIONS ON SITE PLAN  ARE OBTAINED FROM COUNTY ASSESSOR'S
WEBSITE AND ARE TO BE USED AS A POINT OF REFERENCE ONLY. FOR EXACT DIMENSIONS,
PLEASE CONTACT A REGISTERED SURVEYOR.  ARQM Architect SHOULD NOT BE HELD LIABLE
IF THE DIMENSIONS FOUND ON COUNTY ASSESSOR'S WEBSITE ARE INACCURATE, IT IS THE
RESPONSIBILITY OF THE OWNER/CONTRACTOR TO GET A SURVEY OF THE PROPERTY.
CONTRACTOR MUST VERIFY THAT THE FINNISH FLOOR OF THE NEW BUILDING MUST BE AT
LEAST 14" UP FROM THE LOW PART OF THE EXISTING TOP OF CURB.
Contact Arizona 811 at least two full
working days before you begin excavation
CALL 811 or click Arizona811.COM
A.
ANY BROKEN CONCRETE ADJACENT TO THE NEW DRIVEWAY ENTRANCE SHALL BE
REMOVED AND REPLACED PRIOR TO THE CERTIFICATE OF OCCUPANCY BEING
ISSUED.
B.
ANY CONCRETE IN THE RIGHT-OF-WAY BROKEN DURING CONSTRUCTION SHALL BE
REMOVED AND REPLACED PRIOR TO THE CERTIFICATE OF OCCUPANCY BEING
ISSUED.
C.
CONTRACTOR TO LOCATE UTILITY SERVICES PRIOR TO CONSTRUCTION.
D.
WATER AND SEWER SERVICE LOCATIONS AND CONDITIONS SHALL BE FIELD
VERIFIED. BASED ON THE CONDITION, SERVICES MAY BE REQUIRED TO BE REMOVED
AND REPLACED BY OWNER.
NOTES:
SITE PLAN
N
NEW 2821 SQ. FT. LIVABLE CUSTOM RESIDENCE WITH A 2
CAR GARAGE AND FRONT PORCH AND PATIO
3AD NOTE:
DR,9EWAY NOTE:
EXISTING DRIVEWAY ENTRANCE SHALL BE REMOVED AND REPLACED WITH SIDEWALK,
CURB AND GUTTER.
0
10'
20'
SCALE: 1" = 10'-0"

THIS PAGE WAS LEFT INTENTIONALLY BLANK