EQUIPMENT PURCHASE AND SERVICES AGREEMENT
This Equipment Purchase and Services Agreement (“Agreement”) is entered into and effective between CITY OF
GLENDALE, an Arizona municipal corporation (“City”) and Badger Meter, Inc., a Wisconsin corporation with
offices located at 4545 W. Brown Deer Road, Milwaukee, Wisconsin 53223 (“Badger Meter” or "Contractor") , and
authorized to do business in the State of Arizona, (“Contractor”) as of the
(“Effective
Date”).
RECITALS
A.
City desires to purchase certain equipment (“Equipment”) from Contractor for the Advanced Meter
Infrastructure (AMI) project (the “Project”), as set forth in the attached Exhibit A, Schedule of Values
(“SOV”) containing the City’s specifications, standards and criteria;
B.
Contractor is also providing the City with certain professional services (“Services”) to install the equipment
for the Project, as set forth in the attached Exhibit B, Scope of Work (“SOW”) and ensure it is performing
to meet the City’s specifications, industry standards, and the quality standards set forth in this Agreement;
and
C.
City and Contractor desire to memorialize their agreement with this document.
AGREEMENT
The parties hereby agree as follows:
1.
Schedule. The Equipment and Services identified in the SOV and performed in accordance with the SOW
will be built, delivered, installed and provided by the Contractor in a timely and efficient manner. Contractor
will also ensure the equipment will perform as described in the attached as Exhibit C.
2.
Contractor’s Work.
2.1
Relationship Between the Parties. Contractor is supplying the Equipment and performing the
Services required under this Agreement as an independent contractor. Contractor and its employees,
and any Subcontractor and its employees, are not City employees and are not entitled to any benefit
provided to City employees other than those explicitly provided by this Agreement. This Agreement
further does not create any benefits, rights or obligations for any third party not in privity to this
contract.
2.2
Standard and Warranty.
a.
The Contractor expressly warrants the Equipment in accordance with the standard
manufacturer warranties included in Exhibit C herein (the “Warranties”) and further agrees that the
Equipment will:
i.
Conform in all respects to the City’s specifications, drawings, requirements, or other
descriptions.
ii.
Be fit for the purpose or purposes of intended use.
iii. Conform to all applicable local, state, and federal laws, ordinances and regulations.
iv. Be of good quality, merchantable, of good workmanship, or material best suited for
the intended purposes, and free from defects of any kind or nature whatsoever.
b.
With respect to the installation services that are being provided as part of the Services, the
Contractor warrants that such services will be free from defects in workmanship for a period of
twelve (12) months from the date of installation as recorded in the work order management system
utilized for the Project.
2
01/28/2025
c.
All Equipment delivered or supplied hereunder will be free and clear of all liens,
encumbrances, claims, and security interest of whatever nature and substance. Upon request, the
Contractor shall supply the City with documentation satisfactory to it, evidencing the absence of such
liens, encumbrances, claims, and security interests.
d.
All warranty periods shall begin upon when the Equipment is installed.
e.
Contractor must provide, install and operate the Equipment and perform the Services in
accordance with the attached SOW, any applicable standards of due diligence, care, and quality
associated with the successful furnishing of equipment for projects that are equivalent in size, scope,
quality, and other criteria as identified in this Agreement.
g.
The City has expressly consented to allowing Contractor to engage certain subcontractors to
perform some or all of Contractor’s obligations under this Agreement as further stated in the attached
SOW. The City shall not be liable to subcontractor for any claims, including claims for payment for
Services rendered, of any kind.
2.3
Licensing. Contractor further warrants that:
a.
Contractor currently holds all appropriate and required licenses, registrations and other
approvals necessary for the lawful furnishing of the Equipment and Services as contained in
the SOW (“Approvals”); and
b.
Neither Contractor nor any Subcontractor has been debarred or otherwise legally excluded
from contracting with any federal, state, or local governmental entity (“Debarment”).
(1)
City is under no obligation to ascertain or confirm the existence or issuance of any
Approvals or Debarments, or to examine Contractor's contracting ability.
(2)
Contractor must notify City immediately if any Approvals or Debarment changes
during the Agreement's duration. The failure of the Contractor to notify City as
required will constitute a material default under the Agreement.
c.
Background Check. In accordance with the City’s current background check policies, the
City may conduct criminal, driver history, and all other requested background checks of
Contractor personnel who would perform services under the Agreement who will have
access to the City’s information, data, or facilities. Any officer, employee, or agent that fails
the background check must be replaced immediately for any reasonable cause not prohibited
by law.
d.
Security Clearance. The City will have final authority, based on security reasons: (i) to
determine when security clearance of Contractor personnel is required; (ii) to determine the
nature of the security clearance, up to and including fingerprinting Contractor personnel;
and (iii) to determine whether any individual or entity may provide services under this
Agreement. If the City objects to any Contractor personnel for any reasonable cause not
prohibited by law, then Contractor will, upon notice from the City, remove any such
individual from performance of services under this Agreement.
e.
Safeguarding Contractor and City Property. Without limiting the scope or obligation to
indemnify the City as provided in Section 7.2 below and subject to the SOW and the
Warranties, Contractor agrees: (i) to bear all risk of loss, injury, or destruction of its own
Equipment incidental to Contractor providing the Services under this Agreement and that
such loss, injury, or destruction will not release Contractor from any obligation hereunder;
and (ii) it is responsible for any damage or loss to City real or personal property when such
property is the responsibility of or in the custody of Contractor or its personnel.
2.4
Compliance.
a.
Equipment as provided in the SOV and Services as provided in the SOW will be furnished,
installed and operated in compliance with applicable federal, state, county and local statutes,
3
01/28/2025
rules, regulations, ordinances, building codes, life safety codes, and other specifications,
standards and criteria designated by City, including its Drug-Free Workplace policy.
b.
Nothing in this Agreement requires the City to accept Equipment or Services that does not
meet the specifications, standards and criteria contained in the Warranties or the SOW. In
the event the Equipment does not meet the specifications, standards and criteria contained
in the Warranties, the City may, at its sole discretion: (i) reject the Equipment and terminate
this Agreement; or (ii) give the Contractor a reasonable time to cure any defect or non-
compliance.
c.
Contractor must not discriminate against any employee or applicant for employment on the
basis of race, color, religion, sex, national origin, age, marital status, sexual orientation, gender
identity or expression, genetic characteristics, familial status, U.S. military veteran status or
any disability. Contractor will require any Sub-contractor to be bound to the same
requirements as stated within this section. Contractor, and on behalf of any subcontractors,
warrants compliance with this section.
3.
Compensation.
a.
The total not-to-exceed amount available under this Agreement for City’s purchase of Equipment
and Services and for Contractor’s satisfactory performance of all related obligations as specified in this
Agreement, the SOV and the SOW shall not exceed $29,045,000.00. Based on the estimate provided by
Contractor, the not-to-exceed amount has been calculated to include a base amount of $ 26,438,976.67 to
perform the work identified in the SOW and provide the Equipment for the Project identified in the SOV,
plus a contingency fund of the total not-to-exceed amount, equal to $2,606,023.33, for unforeseen or
unanticipated costs. Any contingency funds may only be used to pay for additional Equipment and/or
Services authorized by the City through a Change Order as described in this section. Additional funds for
performing work, activities or tasks for other parts of the overall projects may, but are not required to, be
available under separate contracts or agreements.
b.
Change Orders. Based on the field conditions or other issues encountered during the implementation
of the SOW, the City may authorize changes to the SOW without amending this Agreement. Amending this
Agreement is not required if: (1) the total value of all Change Orders authorized by the City does not exceed
the total amount of Compensation in subsection 3(a) above, which includes the contingency funds set aside
for such purpose; and (2) if the total value of all Changes Orders does exceed the total amount of
Compensation in subsection 3(a) above and the total of a single or all change orders combined to be approved
is less than one hundred thousand dollars ($100,000.00). Any single change order or combination of change
orders which will increase the compensation amount by one hundred thousand dollars ($100,000.00) or more
above the total approved amount (including the contingency funds) in subsection 3(a) above must be
approved by an affirmative vote of the city council.
c.
All Change Orders must be approved by the City prior to the Contractor initiating the performance
of the new, additional or changed Work.
d.
The City may also authorize minor changes to the Scope of Work by issuing a Field Order, provided
such Field Orders do not increase the cost of the work to be performed or materially affect the mutually
agreed upon schedule for the Project. The Contractor shall proceed with the performance of any Field Orders
as required by the City, within two days after formal written documentation has been sent to the Contractor’s
project manager for the Project to effect the minor change incorporated into the Field Order. The Contractor
but may dispute whether it is entitled to an increase to its Compensation based on the cost of implementing
such Field Order as provided in Section 16 of this Agreement only after the work has been completed.
e.
The Contractor shall execute and provide to the City, within 10 calendar days of the Effective Date
of this Agreement, Performance and Payment Bonds with surety in an amount equal to 100% of the amount
of the Compensation (including the contingency funds) available under subsection a above. The sureties of
all Bonds shall be placed or obtained from such surety company or companies as are approved by the City
and are authorized to transact business in the State of Arizona.
4
01/28/2025
4.
Billings and Progress Payments.
4.1
Payment for Equipment. Consistent with Section 9 of the SOW, invoices will automatically be
generated when Equipment manufactured by Badger Meter are shipped. The Contractor will be paid
by ACH NET 30 days from the date the equipment is received in MSI’s warehouse and accepted by
the City. All other invoices will be paid within 30 days of their acceptance by the City. The City must
provide written notice of non-acceptance of delivered Equipment due to non-conformance with the
purchase order within five (5) days of receipt of the Equipment (the “Inspection Period”). If no
written notice is received by the Contractor within the Inspection Period, the Equipment will be
deemed to be accepted for purposes of this Section 4.1.
4.2
Applications for Services.
a.
Subject to Section 9 of the SOW, Contractor will submit its invoice (“Payment Application”)
for Services monthly to City’s Project Manager and City will remit progress payments based
upon the Payment Application as stated below.
b.
The City will process and remit payment of 95% of the charges incurred and billed by
Contractor in the prior month within 30 days, unless the Equipment delivered and installed
or the Services performed do not meet the City’s specifications or the City rejects the
Payment Application for any other reason. The remaining 5% of the Contractor charges
incurred in the prior month will be retained to ensure timely and adequate performance of
the work remaining under the SOW. The 5% retainage due and owing will be released upon
closeout of the Project pursuant to Section 10 of the SOW.
4.3
Review and Withholding. City’s Project Manager will timely review and certify Payment Applications.
a.
If the Payment Application is rejected, the City will issue a written listing of the items not
approved for payment.
b.
City may withhold an amount sufficient to pay expenses that City reasonably expects to incur
in correcting the deficiency or deficiencies rejected for payment.
5.
Termination.
5.1
For Convenience. City may terminate this Agreement for convenience, without cause, by delivering
a written termination notice stating the effective termination date, which may not be less than thirty
(30) days following the date of delivery of notice.
a.
Contractor will not be compensated for Equipment unless it has been delivered to City and
meets the City’s specifications.
b.
Contractor will be equitably compensated for Equipment installed and Services furnished
prior to receipt of the termination notice and for reasonable costs incurred.
c.
Contractor will also be compensated for any approved effort expended, and approved costs
incurred, that are directly associated with project closeout and delivery of the required items to the
City.
5.2
For Cause. In addition to the remedy contained in Section 2.4(b.) above, the City may terminate this
Agreement for cause if Contractor fails to cure any breach of this Agreement within seven (7) days
after receipt of written notice specifying the breach.
a.
Contractor will not be entitled to further payment until after City has determined its damages.
If the City’s damages resulting from the breach, as determined by City, are less than the
equitable amount due but not paid Contractor for Equipment furnished, City will pay the
amount due to Contractor, less City’s damages, in accordance with the provisions of Section
4.
b.
If City’s direct damages exceed amounts otherwise due to Contractor, Contractor must pay
the difference to City immediately upon demand; however, Contractor will not be subject to
5
01/28/2025
consequential damages more than $2,000,000 or the amount of this Agreement, whichever
is greater.
5.3
Lack of Appropriations. Nothing in this Agreement guarantees that some or all of the funds
necessary to comply with all of the City’s obligations under this Agreement will be appropriated or
otherwise be available. The City agrees to seek such appropriations in good faith from the City
Council and agrees not to use the lack of appropriation as a substitute for termination for
convenience. If sufficient funds are not appropriated or otherwise available, the City may unilaterally
terminate this Agreement after providing thirty (30) days written notice. In the event the City
provides such notice, the City will not be entitled to a refund or offset of any amounts previously
paid but will not pay any amounts that become due after providing such notice; provided, however,
the City will remain responsible for the payment of any Goods delivered to the City and any Services
that have been rendered prior to the expiration of the notice period stated above.
5.4
Force Majeure. Failure by either party to perform its duties and obligations will be excused by
unforeseeable circumstances entirely beyond its control, including acts of nature, acts of the public
enemy, riots, fire, explosion, legislation, and pandemic. The party whose performance is so affected
will, within five (5) calendar days of the unforeseeable circumstance, notify the other party of all
pertinent facts and identify the force majeure event. The party whose performance is so affected
must also take all reasonable steps, promptly and diligently, to prevent such causes if it is feasible to
do so or to minimize or eliminate the effect thereof. The delivery or performance date will be
extended for a period equal to the time lost by reason of delay, plus such additional time as may be
reasonably necessary to overcome the effect of the delay, provided however, under no circumstances
will delays caused by a force majeure extend beyond one hundred-twenty (120) calendar days from
the scheduled delivery or completion date of a task unless agreed upon by the parties.
a.
Force majeure shall not include the following circumstances:
i. Late delivery of equipment or materials caused by congestion at a manufacturer’s
plant or elsewhere, or an oversold condition of the market; or
ii. Late performance by a subcontractor unless the delay arises out of a force majeure
occurrence in accordance with this force majeure term and condition; or
iii. Inability of either the Contractor or any subcontractor to acquire or maintain any
required insurance bonds, licenses, or permits.
b.
A party may terminate this Agreement immediately for cause should a Force Majeure
be alleged but determined not to exist to excuse performance.
6.
Conflict. Contractor acknowledges this Agreement is subject to A.R.S. § 38-511, which allows for
cancellation of this Agreement in the event any person who is significantly involved in initiating, negotiating,
securing, drafting, or creating the Agreement on City’s behalf is also an employee, agent, or Contractor of any
other party to this Agreement. Contractor also agrees that this Agreement may be terminated for an act of a
public employee prohibited by A.R.S. § 38-504.
7.
Insurance. For the duration of the term of this Agreement, Contractor shall procure and maintain insurance
against claims for injuries to persons or damages to property which may arise from or in connection with
manufacturing and installing the Equipment and delivering the Services to the City’s specifications or any
other act or activity related to performance under this Agreement. Such insurance shall cover Contractor, its
agent(s), representative(s), employee(s), and any subcontractors and shall name the City, its employees, elected
officials, representatives and volunteers as additional insured.
7.1
Minimum Scope and Limit of Insurance. Coverage must be at least as broad as:
a.
Commercial General Liability (CGL): Insurance Services Office Form CG 00 01 or
equivalent, including products and completed operations, with limits of no less than
$2,000,000 per occurrence for bodily injury, personal injury, and property damage
6
01/28/2025
b.
Automobile Liability: Insurance Services Office Form Number CA 0001 covering Code 1
(any auto) or equivalent, with limits no less than $2,000,000 per accident for bodily injury
and property damage.
c.
Professional Liability. Contractor must maintain a Professional Liability insurance covering
errors and omissions arising out of the work or services performed by Contractor, or anyone
employed by Contractor, or anyone for whose acts, mistakes, errors and omissions
Contractor is legally liability, with a liability insurance limit of $2,000,000 for each claim and
a $4,000,000 annual aggregate limit. For the avoidance of doubt, the Technology Errors and
Omissions endorsement that is part of the Contractor’s cybersecurity policy which has full
prior acts cover will be accepted for purposes of this section.
d.
Worker’s Compensation: Insurance as required by the State of Arizona, with Statutory
Limits, and Employers’ Liability insurance with a limit of no less than $2,000,000 per
accident for bodily injury or disease.
7.2
Indemnification.
a.
To the fullest extent permitted by law, Contractor must defend, indemnify, and hold
harmless City and its elected officials, officers, employees and agents (each, an “Indemnified
Party,” collectively, the “Indemnified Parties”) for, from, and against any and all claims,
demands, actions, damages, judgments, settlements, personal injury (including sickness,
disease, death, and bodily harm), property damage (including loss of use), infringement,
governmental action and all other losses and expenses, including attorneys' fees and litigation
expenses (each, a “Demand or Expense” collectively “Demands or Expenses”) asserted by
a third-party (i.e. a person or entity other than City or Contractor) and that arises out of or
results from the breach of this Agreement by the Contractor or the Contractor’s negligent
actions, errors or omissions (including any Subcontractor or Subcontractor or other person
or firm employed by Contractor), whether sustained before or after delivery of the
Equipment.
b.
This indemnity and hold harmless provision applies even if a Demand or Expense is in part
due to the Indemnified Party’s negligence or breach of a responsibility under this Agreement,
but in that event, Contractor will be liable only to the extent the Demand or Expense results
from the negligence or breach of a responsibility of Contractor or of any person or entity
for whom Contractor is responsible.
c.
Contractor is not required to indemnify any Indemnified Parties for, from, or against any
Demand or Expense resulting from an Indemnified Party’s sole negligence or other fault
solely attributable to any Indemnified Party.
7.3
Other Insurance Provisions. The insurance policies required by the Section above must contain, or
be endorsed to contain the following insurance provisions:
a.
The City, its officers, officials, employees and volunteers are to be covered as
additional insureds of the CGL and automobile policies for any liability arising from or in
connection with the performance of all tasks or work necessary to build and deliver the
Equipment as specified by the City. Such liability may arise, but is not limited to, liability for
materials, parts or equipment furnished in connection with any tasks, or work performed by
Contractor or on its behalf and for liability arising from automobiles owned, leased, hired or
borrowed on behalf of the Contractor. General liability coverage can be provided in the form
of an endorsement to the Contractor’s existing insurance policies, provided such
endorsement is at least as broad as ISO Form CG 20 10, 11 85 or both CG 20 10 and CG
23 37, if later revisions are used or the equivalent of such endorsements.
b.
For any claims related to this Equipment, the Contractor’s insurance coverage shall be
primary insurance with respect to the City, its officers, officials, employees, and volunteers.
Any insurance or self-insurance maintained by the City, its officers, officials, employees or
volunteers shall be in excess of the Contractor’s insurance and shall not contribute with it.
7
01/28/2025
c.
Each insurance policy required by this Section shall provide that coverage shall not be
canceled, except after providing notice to the City.
7.4
Acceptability of Insurers. Insurance is to be placed with insurers with a current A.M. Best rating of
no less than A-: VII, unless the Contractor has obtained prior approval from the City stating that a
non-conforming insurer is acceptable to the City.
7.5
Waiver of Subrogation. Contractor hereby agrees to waive its rights of subrogation which any
insurer may acquire from Contractor by virtue of the payment of any loss. Contractor agrees to
obtain any endorsement that may be necessary to affect this waiver of subrogation. The Workers’
Compensation Policy shall be endorsed with a waiver of subrogation in favor of the City for all work
performed by the Contractor, its employees, agent(s) and subcontractor(s).
7.6
Verification of Coverage. Within fifteen (15) days of the Effective Date of this Agreement,
Contractor shall furnish the City with original certificates and amendatory endorsements, or copies
of any applicable insurance language making the coverage required by this Agreement are effective.
All certificates and endorsements must be received and approved by the City before work
commences. Failure to obtain, submit or secure the City’s approval of the required insurance policies,
certificates or endorsements prior to the City’s agreement that work may commence shall not waive
the Contractor’s obligations to obtain and verify insurance coverage as otherwise provided in this
Section. The City reserves the right to require complete, certified copies of all required insurance
policies, including any endorsements or amendments, or their equivalent required by this Agreement
at any time during the Term stated herein.
Contractor’s failure to obtain, submit or secure the City’s approval of the required insurance policies,
certificates or endorsements shall not be considered a Force Majeure or defense for any failure by
the Contractor to comply with the terms and conditions of the Agreement, including any schedule
for building or delivering the equipment in accordance with the SOW.
7.7
Subcontractors. Contractor shall require and shall verify that all subcontractors maintain insurance
meeting all requirements of this Agreement.
7.8
Special Risk or Circumstances. The City reserves the right to request a modification of these
insurance requirements, including any limits of coverage, based on the nature of the risk, prior
experience, insurer, coverage or other circumstances unique to the Contractor, the SOW or the
insurer by providing thirty (30) days prior written notice and subject to the Contractor’s mutual
written approval of such modification, which such approval shall not be unreasonably withheld. Any
failure of the Contractor to agree to such modification shall not be considered a waiver of any rights
or recovery available or owed to the City under this Agreement.
8.
E-verify, Records, and Audits.
a.
Immigration compliance. To the extent applicable under A.R.S. § 41-4401, the Contractor warrants
their compliance and that of its subcontractors with all federal immigration laws and regulations that relate to
their employees and compliance with the E-verify requirements under A.R.S. § 23-214(A). The Contractor or
subcontractor’s breach of this warranty shall be deemed a material breach of the Agreement and may result
in the termination of the Agreement by the City under the terms of this Agreement. The City retains the legal
right to randomly inspect the papers and records of the other party to ensure that the other party is complying
with the above-mentioned warranty. The Contractor and subcontractor warrant to keep their respective
papers and records open for random inspection during normal business hours by the other party. The parties
shall cooperate with the City’s random inspections, including granting the inspecting party entry rights onto
8
01/28/2025
their respective properties to perform the random inspections and waiving their respective rights to keep such
papers and records confidential.
b.
Contractor must preserve the records related to this Agreement for six (6) years after completion of
the SOW. The City or its authorized agent reserves the right to inspect any records related to the performance
of work specified herein at reasonable times.
c.
The parties agree that documents and records developed, generated, exchanged, maintained, or
retained related to this Agreement will be subject to public inspection and disclosure to comply with Arizona
public records laws (A.R.S. §39-121 et seq.) unless they are determined to be confidential or sensitive or
contain proprietary or trade secrets as defined by the Arizona Trade Secrets Act by an administrative or
governmental body or court of competent jurisdiction.
9.
No Boycott of Israel. To the extent A.R.S § 35-393 through § 35-393.03 are applicable, the parties hereby
certify that they are not currently engaged in, and agree for the duration of the Agreement to not engage in, a
boycott of goods or services from Israel, as that term is defined in A.R.S § 35-393.
10.
Uyghur Forced Labor Prevention Act (UFLPA). Contractor certifies that it does not currently, and during
the term of this Agreement, will not use:
a.
the forced labor of ethnic Uyghurs in the People’s Republic of China;
b.
any goods or services produced by the forced labor of ethnic Uyghurs in the People’s
Republic of China; and
c.
any contractors, subcontractors or suppliers that use the forced labor or any goods or
services produced by the forced labor of ethnic Uyghurs in the People’s Republic of China.
11.
INTENTIONALLY OMITTED.
12.
Notices.
12.1
A notice, request or other communication that is required or permitted under this Agreement (each
a “Notice”) will be effective only if:
a.
The Notice is in writing; and
b.
Delivered in person or by overnight courier service (delivery charges prepaid), certified or
registered mail (return receipt requested).
c.
Notice will be deemed to have been delivered to the person to whom it is addressed as of
the date of receipt, if:
(1)
Received on a business day before 5:00 p.m. at the address for Notices identified
for the Party in this Agreement by U.S. Mail, hand delivery, or overnight courier
service; or
(2)
As of the next business day after receipt, if received after 5:00 p.m.
d.
The burden of proof of the place and time of delivery is upon the Party giving the Notice.
e.
Digitalized signatures and copies of signatures will have the same effect as original signatures.
12.2
Representatives.
a.
Contractor. Contractor’s representative (the “Contractor’s Representative”) authorized to
act on Contractor’s behalf with respect to the Agreement, and his or her address for Notice
delivery is:
Badger Meter Inc.
Attn: Legal Department
4545 W. Brown Deer Road
Milwaukee, WI 53223
9
01/28/2025
b.
City. City’s representative (“City’s Representative”) authorized to act on City’s behalf, and
his or her address for Notice delivery is:
Ron Serio, Water Services Director
City of Glendale
7070 W Northern Avenue
Glendale, AZ 85303
With required copy to:
City Manager
City Attorney
City of Glendale
City of Glendale
5850 West Glendale Avenue
5850 West Glendale Avenue
Glendale, Arizona 85301
Glendale, Arizona 85301
c.
Concurrent Notices.
(1)
All notices to City’s representative must be given concurrently to City Manager and
City Attorney.
(2)
A notice will not be deemed to have been received by City’s representative until the
time that it has also been received by the City Manager and the City Attorney.
(3)
City may appoint one or more designees for the purpose of receiving notice by
delivery of a written notice to Contractor identifying the designee(s) and their
respective addresses for notices.
d.
Changes. Contractor or City may change its representative or information on Notice, by
giving Notice of the change in accordance with this section at least ten days prior to the
change.
13.
Entire Agreement; Survival; Counterparts; Signatures.
13.1
Integration. This Agreement contains, except as stated below, the entire agreement between City
and Contractor and supersedes all prior conversations and negotiations between the parties regarding
the Equipment, the Services or this Agreement.
a.
Neither Party has made any representations, warranties, waivers or agreements as to any
matters concerning the Agreement’s subject matter.
b.
Representations, statements, conditions, waivers, or warranties not contained in this
Agreement will not be binding on the parties.
c.
The solicitation, any addendums and the response submitted by the Contractor are
incorporated into this Agreement as if attached hereto. Any Contractor response modifies
the original solicitation as stated. Inconsistencies between the solicitation, any addendums
and the response or any excerpts attached as Exhibit A and this Agreement will be resolved
by the terms and conditions stated in this Agreement.
13.2
Interpretation.
a.
The parties fairly negotiated the Agreement’s provisions to the extent they believed necessary
and with the legal representation they deemed appropriate.
b.
The parties are of equal bargaining position and this Agreement must be construed equally
between the parties without consideration of which of the parties may have drafted this
Agreement.
c.
The Agreement will be governed by and interpreted in accordance with the laws of the State
of Arizona. Venue for any disputes arising under this Agreement shall be Maricopa County,
Arizona.
10
01/28/2025
13.3
Survival. Except as specifically provided otherwise in this Agreement, each warranty, representation,
indemnification and hold harmless provision, insurance requirement, and every other right, remedy
and responsibility of a Party, will survive completion of the Equipment, or the earlier termination of
this Agreement.
13.4
Amendment. No amendment to this Agreement will be binding unless in writing and executed by
the parties. Electronic signature blocks do not constitute execution for purposes of this Agreement.
Any amendment may be subject to City Council approval.
13.5
Remedies. All rights and remedies provided in this Agreement are cumulative and the exercise of
any one or more right or remedy will not affect any other rights or remedies under this Agreement
or applicable law.
13.6
Severability. If any provision of this Agreement is voided or found unenforceable, that determination
will not affect the validity of the other provisions, and the voided or unenforceable provision will be
reformed to conform with applicable law.
13.7
Counterparts. This Agreement may be executed in counterparts, and all counterparts will together
comprise one instrument.
13.8
Assignment. This Agreement may not be assigned, either in whole or in part, without first receiving
the City’s written consent. Any attempted assignment, either in whole or in part, without such consent
will be null and void and in such event the City will have the right, at its option, to terminate the
Agreement.
13.9
Binding Effect. This Agreement will be binding upon and inure to the benefit of the parties and
their respective permitted successors and assigns.13.10
Use of City Name or Trademark.
Nothing in this Agreement gives the Contractor any right to use the name, logo, trademark,
copyrighted materials or similar identifying features of the City of Glendale in any advertising or
publicity without obtaining the prior written consent of the City.
14.
Term.
The term of this Agreement commences upon the Effective Date and continues until all Equipment is
installed and accepted by the City and all Services are performed to the City’s satisfaction, or for a three (3)
year period beginning on the Effective Date of this Agreement, whichever is shorter. In the event all tasks
required by the SOW, including the installation of the Equipment and performance of all Services has not
been completed before the Term expires, the parties may agree in writing to up to three (3) six-month
extensions (a total of 18 months) to complete the work in the SOW. For purposes of the Agreement
“accepted” means the Contractor has delivered and properly installed the Equipment and all Services have
been provided and implemented in accordance with the SOW.
15.
Liquidated Damages.
The City, in its sole unreviewable discretion, may assess liquidated damages in the amount of $1,000 per day
per violation for any failure by the Contractor to: (i) install the Equipment in compliance with the schedule
contained in the SOW; (ii)fail or refuse to provide the Services contracted for under this Agreement or
perform them in compliance with the SOW; or (iii) meet any other material provision of the SOW that
prevents the Equipment from being fully functional by the agreed upon Project Completion Date. Nothing
in this provision, however, waives any right the City may have to seek any other damages or remedies available
to it under this Agreement, including any damages or remedies for a breach of warranty that may be provided
in Section 2.2 above, the SOV or the SOW.
16.
Dispute Resolution.
a.
Any controversy or claim arising out of or relating to this contract, or the breach thereof, shall be
settled by arbitration administered according to the American Arbitration Association’s Commercial
Arbitration Rules, and judgment on the award rendered by the arbitrator may be entered in any court having
jurisdiction thereof.
11
01/28/2025
b.
Contractor agrees that during the pendency of any dispute between the parties, Contractor will
continue to perform its obligations until the dispute is settled, instructed to cease performance by the City,
enjoined or prohibited by judicial action, or otherwise required or obligated to cease performance by other
provisions in this Agreement.
17.
Cooperative Use of Contract. This agreement may be extended for use by other governmental agencies
and political subdivisions of the State upon the Contractor’s mutual written agreement. Any such usage by
other entities must be in accord with the ordinances, charter, rules and regulations of the respective entity and
the approval of the Contractor and City. For a list of SAVE members, click on the following link:
http://www.mesaaz.gov/business/purchasing/save
18.
Exhibits. The following exhibits, with reference to the term in which they are first referenced, are
incorporated by this reference.
Exhibit A
Schedule of Values
Exhibit B
Scope of Work
Exhibit C
Manufacturer’s Equipment Warranties
Exhibit D
RFP Response Workbook
(The remainder of this page left blank intentionally. Signatures appear on the following page.)
12
01/28/2025
The parties enter into this Agreement effective as of the date shown above.
City of Glendale,
an Arizona municipal corporation
____________________________________
ATTEST:
Julie K. Bower
(SEAL)
City Clerk
APPROVED AS TO FORM:
Michael D. Bailey
City Attorney
Badger Meter, Inc.,
a Wisconsin corporation
____________________________________
By:
Its:
EXHIBIT A
Equipment Purchase Agreement
SCHEDULE OF VALUES
.
ITEM
BMI Description
Unit
QUANTITY
PER CONTRACT
TOTAL UNIT PRICE
IN CONTRACT -
EXCL TAX
ORIGINAL TOTAL
EXT PRICE IN
CONTRACT EXCL
TAX
TOTAL EXT PRICE IN
CONTRACT EXCL TAX
- w/ Change Orders
RADAR Service Units
Unit
QUANTITY
PER CONTRACT
TOTAL UNIT PRICE
IN CONTRACT -
EXCL TAX
ORIGINAL TOTAL
EXT PRICE IN
CONTRACT EXCL
TAX
TOTAL EXT PRICE IN
CONTRACT EXCL TAX
- w/ Change Orders
1
RADAR STD ACOUSTICS SERV UNIT - Year 1
EA
0
15.00
$
-
$
-
$
2
RADAR STD ACOUSTICS SERV UNIT - Year 2
EA
0
15.00
$
-
$
-
$
3
RADAR STD ACOUSTICS SERV UNIT - Year 3
EA
0
15.00
$
-
$
-
$
4
RADAR STD ACOUSTICS SERV UNIT - Year 4
EA
0
15.23
$
-
$
-
$
5
RADAR STD ACOUSTICS SERV UNIT - Year 5
EA
0
15.45
$
-
$
-
$
6
RADAR STD ACOUSTICS SERV UNIT - Year 6
EA
0
15.69
$
-
$
-
$
7
RADAR STD ACOUSTICS SERV UNIT - Year 7
EA
0
15.92
$
-
$
-
$
8
RADAR STD ACOUSTICS SERV UNIT - Year 8
EA
0
16.16
$
-
$
-
$
9
RADAR STD ACOUSTICS SERV UNIT - Year 9
EA
0
16.40
$
-
$
-
$
10
RADAR STD ACOUSTICS SERV UNIT - Year 10
EA
0
16.65
$
-
$
-
$
11
RADAR STD ACOUSTICS SERV UNIT - Year 11
EA
0
16.90
$
-
$
-
$
12
RADAR STD ACOUSTICS SERV UNIT - Year 12
EA
0
17.15
$
-
$
-
$
13
RADAR STD ACOUSTICS SERV UNIT - Year 13
EA
0
17.41
$
-
$
-
$
14
RADAR STD ACOUSTICS SERV UNIT - Year 14
EA
0
17.67
$
-
$
-
$
15
RADAR STD ACOUSTICS SERV UNIT - Year 15
EA
0
17.93
$
-
$
-
$
16
RADAR STD ACOUSTICS SERV UNIT - Year 16
EA
0
18.20
$
-
$
-
$
17
RADAR STD ACOUSTICS SERV UNIT - Year 17
EA
0
18.48
$
-
$
-
$
18
RADAR STD ACOUSTICS SERV UNIT - Year 18
EA
0
18.75
$
-
$
-
$
19
RADAR STD ACOUSTICS SERV UNIT - Year 19
EA
0
19.03
$
-
$
-
$
20
RADAR STD ACOUSTICS SERV UNIT - Year 20
EA
0
19.32
$
-
$
-
$
SIM Leak Detection Service Units
21
SIM LEAK DECTECTION 500BM SERV UNIT - Year 1
EA
0
15.00
$
-
$
-
$
22
SIM LEAK DECTECTION 500BM SERV UNIT - Year 2
EA
0
15.00
$
-
$
-
$
23
SIM LEAK DECTECTION 500BM SERV UNIT - Year 3
EA
0
15.00
$
-
$
-
$
24
SIM LEAK DECTECTION 500BM SERV UNIT - Year 4
EA
0
15.23
$
-
$
-
$
25
SIM LEAK DECTECTION 500BM SERV UNIT - Year 5
EA
0
15.45
$
-
$
-
$
26
SIM LEAK DECTECTION 500BM SERV UNIT - Year 6
EA
0
15.69
$
-
$
-
$
27
SIM LEAK DECTECTION 500BM SERV UNIT - Year 7
EA
0
15.92
$
-
$
-
$
28
SIM LEAK DECTECTION 500BM SERV UNIT - Year 8
EA
0
16.16
$
-
$
-
$
29
SIM LEAK DECTECTION 500BM SERV UNIT - Year 9
EA
0
16.40
$
-
$
-
$
30
SIM LEAK DECTECTION 500BM SERV UNIT - Year 10
EA
0
16.65
$
-
$
-
$
31
SIM LEAK DECTECTION 500BM SERV UNIT - Year 11
EA
0
16.90
$
-
$
-
$
32
SIM LEAK DECTECTION 500BM SERV UNIT - Year 12
EA
0
17.15
$
-
$
-
$
33
SIM LEAK DECTECTION 500BM SERV UNIT - Year 13
EA
0
17.41
$
-
$
-
$
Page of
ITEM
BMI Description
Unit
QUANTITY
PER CONTRACT
TOTAL UNIT PRICE
IN CONTRACT -
EXCL TAX
ORIGINAL TOTAL
EXT PRICE IN
CONTRACT EXCL
TAX
TOTAL EXT PRICE IN
CONTRACT EXCL TAX
- w/ Change Orders
34
SIM LEAK DECTECTION 500BM SERV UNIT - Year 14
EA
0
17.67
$
-
$
-
$
35
SIM LEAK DECTECTION 500BM SERV UNIT - Year 15
EA
0
17.93
$
-
$
-
$
36
SIM LEAK DECTECTION 500BM SERV UNIT - Year 16
EA
0
18.20
$
-
$
-
$
37
SIM LEAK DECTECTION 500BM SERV UNIT - Year 17
EA
0
18.48
$
-
$
-
$
38
SIM LEAK DECTECTION 500BM SERV UNIT - Year 18
EA
0
18.75
$
-
$
-
$
39
SIM LEAK DECTECTION 500BM SERV UNIT - Year 19
EA
0
19.03
$
-
$
-
$
40
SIM LEAK DECTECTION 500BM SERV UNIT - Year 20
EA
0
19.32
$
-
$
-
$
Page of
14
01/28/2025
EXHIBIT B
Equipment Purchase Agreement
SCOPE OF WORK
15
01/28/2025
EXHIBIT C
Equipment Purchase Agreement
Manufacturer’s Equipment Warranties
Warranty and Additional Exclusions
Each unit, software and service is provided subject to the warranty terms in the Badger Meter
Terms and Conditions of Sale, along with the applicable terms and limitations therein, which is
available at:
as well as the additional
conditions and exclusions listed below.
All Syrinix
units are to be installed in accordance with the technical
installation documentation and other guidance separately provided. An electronic copy of
applicable operating and installation documentation will be made available via the RADAR
platform.
Please note that this proposal does not include the provision of any of the following by
unless expressly agreed otherwise in writing:
site access and preparation including any connection, valves and tappings required for
the connection of each unit;
field work including unit preparation, connection, testing and operation unless agreed
otherwise in writing;
local duties and taxes;
all applicable/required permits, licenses and analogous fees;
civil, structural, architectural and design work of any kind;
interconnections, pipes, valves and fittings which are not part of the supplied
equipment; all testing and system verifications other than to
standards;
painting or special finishes; and
all items not specifically listed.
Battery life is exempt from the product warranty but if used in areas of good signal and in
accordance with our standard operating instructions will deliver the battery life between
charges as indicated.
Any warranty claims must be made by contacting
to obtain a return
authorization and then returning the unit back
responsibility to cover the costs of the return carriage.
reserves
the right to charge for costs incurred where any fault is a result of a breach by the user.
Please note that this warranty does not cover:
any excluded matter detailed above, communications interruptions due to third party
intervention and/or failure including but not limited to communications network provider,
unauthorized access and/or tampering or other form of interference, whether related to
hardware, communications and/or software;
failures interruptions and damage resulting directly or indirectly from Acts of God, war,
terrorism, civil, disobedience, theft, extreme weather, floods, storms, lightning, tornado,
hurricane, fire, combustion, explosion, landslip, volcano and earthquake, extreme
temperature, external electrical irregularity including surge and failure, acoustic
interference,
damage from water borne materials, corrosion from unanticipated liquids and materials
and external electromagnetic interference and all and any external events analogous to
any of the above;
theft, vandalism, or other damaging acts whether intentional or accidental;
battery failure beyond that level of warranty provided by the manufacturer (please see
above)
Page 42 of 55
installation, commissioning, use and/or removal (temporary or permanent), tampering,
and unapproved opening;
intentional or accidental abuse, interference, misuse or neglect of the hardware failures
resulting from the negligence to perform preventative maintenance
damages or defects in the product which are caused by initial start-up, repairs or
attempted repairs performed by anyone other than a
authorized service
provider
installation guidance;
unavailability of GPS or communications networks;
customer in default of any payment obligations to
;
abuse by abnormal system conditions including but not limited to temperature, chemical
or debris;
goods that have been improperly stored by owner or its representative prior to
installation and start-up;
equipment/programming which has been revised or altered by others.
The information provided in this document is confidential and should not be
reproduced, used or disclosed in any way, without the prior written consent of
.
Page 43 of 55
16
01/28/2025
EXHIBIT D
Equipment Purchase Agreement
RFP Response Workbook
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
1.1
Water Meters
Design
Meters shall comply with the lead-free requirements as defined in NSF/ANSI 61 and NSF/ANSI
372 and by the 2014 provisions of the Safe Drinking Water Act which defines lead-free as not
more than a weighted average of 0.25% lead when used with respect to the wetted surfaces
of pipes, pipe fittings, plumbing fittings, and fixtures.
Must Have
Yes
1.2
Water Meters
Design
All Meters shall have cast on them, in raised characters, the meter size and direction of flow
through the meter.
Must Have
Yes
1.3
Water Meters
Design
All Meters shall have the manufacturer's serial numbers stamped on the meter main case and
on top of the reading lid.
Must Have
Yes
1.4
Water Meters
Registers
The registers shall provide for visual register reading at the meter and encoded data for use
by advanced metering systems.
Must Have
Yes
1.5
Water Meters
Registers
The register shall be straight reading type with test and low flow indicators and shall be
constructed to register in gallons.
Must Have
Yes
1.6
Water Meters
Registers
All register electronics and/or reduction gearing shall be contained in a hermetically sealed,
tamper proof enclosure constructed of corrosion-resistant material and shall be secured to
the upper main case by means of a locking device or integrated into the maincase.
Must Have
Yes
1.7
Water Meters
Registers
The register box and reading lid must be constructed of bronze or suitable engineered plastic.
The register lens shall be constructed of high-impact tempered glass
Must Have
Yes
1.8
Water Meters
Registers
The register shall encode a minimum of 9-meter registration digits configured based on the
meter size.
Must Have
Yes
1.9
Water Meters
Design - Registers
Registers shall offer support for remote programming of alarm and meter configurations
through the Endpoint via 2-way communication.
Desired
No
Although our registers do not support remote programming of alarms and meter
configurations, consumption based alarms using "Events" can be configured in BEACON
without the need to program the encoder.
"Events" empowers users to proactively monitor their data by setting system thresholds,
selecting which data to monitor, and establishing conditions for each event type. While
BEACON monitors the incoming data in real-time, it can quickly identify anomalies and act
by sending notifications to the right personnel. This includes not only user-defined flow
and endpoint communication events, but also temperature and pressure events when
using our E-Series G2 Ultrasonic meters. The ability to monitor flow, communication, water
temperature and water pressure events lets utilities immediately confirm customer-
reported issues. Such monitoring can eliminate the need for unnecessary truck rolls. By
leveraging these capabilities, utility operations can be improved by identifying and
addressing issues before customers notice them and/or become larger problems.
1.10
Water Meters
Design - Registers
The register shall support localized interval data history storage and retrieval for all available
measurements (consumption, temperature, pressure, etc.), with configurable interval periods
down to 5 minutes or less and a minimum storage capacity of 288 consecutive intervals.
Desired
No
To protect against data loss, the system has multiple levels of redundancy. As a standard,
the ORION Cellular endpoint can store up to 42 days of 15-minute interval data, equating
to 4,032 data points which can be extracted at the meter, if needed. Moreover, BEACON
provides the ability to access the past three years of 15-minute data from all endpoints in
the system. Interval data, alarms, events, and diagnostic information is stored in BEACON.
While localized data extraction can be performed, our standard interval for all
measurements is 15 minutes.
1.11
Water Meters
Design - Registers
The register shall provide configurable alarms for leak, broken pipe, reverse flow, and tamper
conditions.
Must Have
No
Using the PCU, alarms can be turned on or off. While thresholds for alerts are factory set
and not configurable, the pressure and temperature limits in our E-Series Ultrasonic meters
do allow for configurable thresholds. Additionally, the customer can reconfigure the
duration for which alarms will last and how long they are sent to BEACON, with the
exception of the leak alarm, which clears automatically. Importantly, our BEACON software
enhances this capability by providing the City with customizable alerts for these critical
conditions through “Events”. This flexibility empowers the City to respond promptly and
effectively to any potential issues.
1.12
Water Meters
Design - Meter Height
5/8"x3/4", 3/4" and 1" meters shall not exceed 4" from centerline to top of register.
Must Have
Yes
1.13
Water Meters
Registers
Encoder registers shall have a minimum battery life of twenty years.
Must Have
Yes
1.14
Water Meters
Design
Meters shall be maintenance free and contain no internal moving parts.
Must Have
Yes
1.15
Water Meters
Design
All nuts, washers, and bolts in meter and on meter body shall be stainless steel.
Must Have
Yes
1.16
Water Meters
Headloss
Meters shall not exceed a maximum allowable pressure loss of 10 pounds per square inch at
the safe maximum operating capacity for a given meter size.
Must Have
Yes
1.17
Water Meters
Accuracy
Meters shall be able to sense and indicate reverse flow.
Must Have
Yes
1.18
Water Meters
Pressure Capacity
Meters shall operate properly under a continuous working pressure of 150 pounds per square
inch (psi) without leakage or damage to any meter components.
Must Have
Yes
1.19
Water Meters
Design - Registers
Ultrasonic meters shall have an electronic register with LCD display and shall be capable of
meeting the register features described in this section. Electronic registers shall be factory
sealed. The Owner will not accept any register filled with oil or any substance intended to
prevent moisture intrusion
Must Have
Yes
1.20
Water Meters
Design - Registers
Registers shall be capable of being located within a pit (underground) environment and
perform accurately in hot temperatures and submerged in water.
Must Have
Yes
1.21
Water Meters
Design - Registers
Battery life remaining shall be displayed on the register.
Desired
Yes
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
1.22
Water Meters
Connectors
Encoded registers shall be compatible with Itron inline connector or Nicor connector and shall
be supplied with a 5’ wire. The connector type will be determined by the chosen AMI vendor.
Field splicing of wires as the standard installation method is not acceptable.
Desired
Yes
1.23
Water Meters
Design - Registers
Register shall clearly differentiate the billing read (1000 gallons) and the raw read (1/10
gallon).
Must Have
Yes
1.24
Water Meters
Design - Registers
Register dial numbers shall be easily distinguishable in low light environment from at least 5
feet away.
Desired
Yes
1.25
Water Meters
Design - Registers
Reads shall still be obtainable on-site in the event of the LCD screen failing or battery failure.
Desired
No
In the event the battery fails, data will be unretrievable. If the LCD fails, data can be
retrieved locally.
1.26
Water Meters
Design - Registers
The register lens shall resist breakage and scoring under normal conditions.
Must Have
Yes
1.27
Water Meters
Design - Registers
The register/encoder programmer shall be capable of applying the same settings across
multiple registers/encoders without requiring re-entry of the settings.
Desired
Yes
Our E-Series Ultrasonic meters can come factory programmed without the need for
programming to be performed in the field.
1.28
Water Meters
Design - Registers
Register shall use high resolution ASCII encoder protocol.
Must Have
Yes
1.29
Water Meters
Design - Registers
Register shall be non-removable from the meter and must have a lid that covers/protects the
register display.
Desired
Yes
1.30
Water Meters
Advanced Features
Meter shall optionally be able to record and relay temperature and pressure measurements.
Strongly Desired
Yes
1.31
Water Meters
Advanced Features
The meter shall provide configurable thresholds for temperature and pressure high/low
alarms.
Strongly Desired
Yes
1.32
Water Meters
Design-Lay Length
Meters shall be available in common lay lengths as indicated in AWWA Standard C715-18.
Must Have
Yes
1.33
Water Meters
Operating Characteristics
The meter shall offer empty pipe alarms
Desired
Yes
1.34
Water Meters
Proposal Requirements
All complete operating and parts manuals shall be furnished upon delivery at no additional
cost to the Owner. Manuals and other materials shall show all meter specifications and
mechanical troubleshooting in paper and electronic media.
Must Have
Yes
1.35
Water Meters
Shut-Off Valves
Remotely actuated shutoff valves shall be optionally integrated with the meter and support
on-demand state changes and confirmation via Endpoint communications. Valve states shall
include open, closed, and reduced flow.
Nice To Have
No
As a separate option from the standard E-Series Ultrasonic meter, Badger Meter also offers
the E-Series Ultrasonic Plus with Integrated Valve. The valve features three positions:
open, partially closed, and restricted. While not intended to provide a complete shut-off,
the E-Series Ultrasonic Plus with Integrated Valve allows utilities to restrict water flow to a
minimum of 0.125 gpm for humanitarian reasons. Additionally, the valve actuation can
either be scheduled for a specific date in the future or during the next communication
cycle.
1.36
Water Meters
Type
Meters shall be solid state, battery operated meters with electronics in a totally encapsulated,
waterproof housing. Meter and register shall be a single unit with no moving parts in the flow
path, however, meters with removable and replaceable electronics are allowable.
Must Have
Yes
1.37
Water Meters
Design
The meters external casing shall be constructed of composite plastic, lead-free bronze alloy or
stainless-steel enclosure, which permanently houses the meter elements. Flow tubes shall be
constructed of lead-free bronze or stainless-steel.
Must Have
Yes
1.38
Water Meters
Operating Capacity
Meters shall have the capability to operate under flow conditions as specified in AWWA
Standard C715-18
Must Have
Yes
1.39
Water Meters
Operating Characteristics
Main case connections for 1-1/2” and 2” meters must have standard ANSI integral flanges
cast into the meter casing or swivel with elliptical flange and have a bolt pattern with enough
clearance for bolts to be inserted from opposite side of meter.
Must Have
Yes
1.40
Water Meters
Accuracy
Meters sizes 5/8", 5/8" x 3/4", 3/4", and 1" shall meet or exceed current AWWA C715-18
(R22) new meter low, normal, and high flow new meter accuracy standards for a minimum
period of twenty years from the date of manufacture.
Must Have
Yes
1.41
Water Meters
Accuracy
Meters sizes starting at 1-1/2" and larger shall meet or exceed current AWWA C715-18 (R22)
new meter low, normal, and high flow new meter accuracy standards for a minimum period
of ten years from the date of manufacture.
Must Have
Yes
1.42
Water Meters
Environmental tolerances
Water Meters shall operate over a temperature range of at least -30º F to 140º F, and a
humidity range of at least 0% to 100% non-condensing.
Must Have
Yes
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement (Yes /
No)
Comments
2.1
Non-Metallic Meter Covers
General
Meter covers shall be non-metallic, black in color, and constructed of high-impact, no break
polymer or composite plastic.
Must Have
Yes
2.2
Non-Metallic Meter Covers
General
Meter covers shall be field locatable through use of a metal detector.
Desired
Yes
DFW uses a magnent for locating molded in the lids- no
metal attachment
2.3
Non-Metallic Meter Covers
General
Meter covers shall fit within the existing City of Glendale meter boxes without the need for
meter box replacement or modifications.
Must Have
Yes
City of Glendale has installed DFW lids- We have all sizes
2.4
Non-Metallic Meter Covers
Duty Rating - Regular Duty
Regular Duty meter covers in areas not expected to be exposed to vehicular traffic shall be
rated to withstand at least a 20,000-pound load, plus impact, as measured via testing in
accordance with paragraph 6.1 of AASHTO M306 without any damage of permanent
deformation in excess of 1/8".
Must Have
Yes
All materials quoted from DFW meet AASHTO H20
standards, not M306. Per Addendum 5 the City will accept
H20 20k load testing standards.
2.5
Non-Metallic Meter Covers
Duty Rating - Traffic Rated
Traffic Rated meter covers in areas exposed to vehicular traffic shall be rated to withstand at
least a 40,000-pound load, plus impact, as measured via testing in accordance with
paragraph 6.1 of AASHTO M306 without any damage of permanent deformation in excess of
1/8".
Must Have
Yes
Per the City in Addendum 5, AASHTO H20 is acceptable. For
larger high traffic rated cover needs, further evaluation will
be needed. YES, DFW MEETS THE H-20 REQUIREMENT
ALLOWED IN ADDENDUM 5.
2.6
Non-Metallic Meter Covers
Size and Geometry
The specified meter covers shall come in sizes compatible with the City's existing water meter
boxes
Must Have
Yes
Glendale MAG/Tucson sizes. Glendale has used DFW
products in City
2.7
Non-Metallic Meter Covers
Design
The cover shall withstand a temperature range of -40-degree F to 190-degree F and shall be
resistant to ultraviolet light degradation, corrosion, and be unaffected by rain or
condensation, frost-proof, and compatible with rugged service and long life.
Must Have
Yes
There is no standardized test for tempature variation. See
attached local references of Cities near Glendale that see
the most extreme of the AZ weather.
2.8
Non-Metallic Meter Covers
Design
The cover shall have a slip-resistant surface having a molded tread pattern for skid resistance. Must Have
Yes
DFW has molded thread pattern and has minnimum
coefficeint friction of 0.50 to exceed testing requirements of
Western Underground 3.6
2.9
Non-Metallic Meter Covers
Design
As required for the proposed endpoints, each cover shall be furnished with a recess and a
hole to accommodate the selected AMI transmitter OR shall optionally be available with
mounting brackets to facilitate under-the-cover installation of an endpoint.
Must Have
Yes
DFW has mold inserts for all meter manufactures, different
depths, and sizes according manufactures size for ADA, to
sit flush with top of lid
2.10
Non-Metallic Meter Covers
Design
Meter covers shall be designed to prevent being easily displaced or from floating during rain
events through integrated weighting or another appropriate mechanism.
Must Have
Yes
DFW has anti float blended material with min relative
density of 1.10 according to ASTM d792-08 test methods.
Does not include metal for weight
2.11
Non-Metallic Meter Covers
Design
Each cover shall have molded in its superior part of its body the words "Water Meter" The
words shall be legible and shall be molded permanently in the body of the Lid.
Desired
Yes
DFW has "Water Meter" molded on the lids and can do
custom city logo at no additional charge
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
3.1
AMI Endpoints
Backfilling Reads
AMI system shall recover and retransmit missing reads from each endpoint to backfill
missing interval data on a daily basis.
Must Have
Yes
3.2
AMI Endpoints
Batteries
The expected battery life of Endpoints shall be at least twenty (20) years. The Owner
expects Endpoint low battery alarms to be fully warranted prior to failure.
Must Have
Yes
3.3
AMI Endpoints
Batteries
The Endpoint shall alert when the battery is reaching end-of-life.
Desired
Yes
3.4
AMI Endpoints
Data transmission accuracy and
security
AMI system shall include provisions to ensure immunity from outside (electromagnetic)
interference as well as fading and other forms of signal degeneration or attenuation (such
as multi-path fading), to prevent accidental loss or interception of customer or meter
reading data.
Must Have
Yes
3.5
AMI Endpoints
Environmental tolerance
Endpoints must operate in conditions subject to indefinite water submergence (i.e., meter
vaults).
Must Have
Yes
Being submerged in water will affect signal propagation
which will affect any RF transmitting device. If installed
outdoors, the ORION Cellular endpoints must be
installed through RF-friendly lids, per the ORION Water
Endpoint Installation Manual, to optimize signal
propagation and endpoint performance. Per the ORION
Water Endpoint Installation Manual, ORION Cellular
endpoints must be installed through RF-friendly lids to
optimize signal propagation and endpoint performance.
Beyond the endpoint mounting, the equipment is
suitable for submerging in water.
3.6
AMI Endpoints
Environmental tolerance
Endpoint enclosure should be composed of UV-inhibiting ABS or similar material. All
materials used in the Endpoint must be non-hazardous.
Must Have
Yes
3.7
AMI Endpoints
Environmental tolerance
Ruggedized connection cables shall be available for installations that require extra
protection from rodents or physical damage.
Must Have
Yes
To enhance durability and match the ruggedness of our
products, all component wires can be fitted with rodent
prevention sleeves, safeguarding against potential
damage from insects, rodents, and other wildlife.
3.8
AMI Endpoints
Hydrant Meter
Endpoints shall be compatible with temporary hydrant meters.
Must Have
Yes
3.9
AMI Endpoints
ID Number
Each Endpoint shall have a unique, permanent ID number that is transmitted with the meter
readings.
Must Have
Yes
3.10
AMI Endpoints
Extended Protocols
Endpoints must be capable of accepting extended protocols for meter level alarms and over
the air register communication.
Must Have
Yes
Please see our compatibility statement available in our
Product Data Sheet or Installation Manual.
3.11
AMI Endpoints
Labeling
Endpoints shall be permanently labeled with manufacturer’s name, model number, owner
name (Glendale), a tamper warning, Endpoint identification number, required FCC labeling,
input/output connections, and date of manufacture.
Must Have
No
The ORION Cellular endpoints are permanently labeled
with the following information:
Endpoint manufacturer and model
Numeric serial number
Barcoded serial number
Federal Communications Commission (FCC) ID
When wired to a Badger Meter encoder, the encoder
contains the following information:
Manufacturer’s name
Meter model
Unit of measure
Date of manufacture
Further physical labeling of other attribute would not be
available on the product. Note that attributes such as
tamper warnings and date of manufacture are readily
available in BEACON.
3.12
AMI Endpoints
Labeling
Endpoints shall be labeled with a bar code of the Endpoint identification number. The label
shall be weatherproof and attached to the Endpoint where normal installation will not
obscure it.
Must Have
Yes
3.13
AMI Endpoints
Leak detection - Mains
AMI system shall provide acoustic or pressure based distribution system leak detection and
to transmit this data via the data collector network to the control computer.
Strongly Desired
Yes
Badger Meter offers a variety of different pressure and
acoustic sensors using the very same cellular network as
the AMI.
3.14
AMI Endpoints
Meter Interface Unit (Endpoint) Endpoints must be available in versions that work in water meter vaults as well as inside
buildings.
Must Have
Yes
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
3.15
AMI Endpoints
Meter Reading Intervals
Changes to meter reading and Endpoint transmission intervals shall be able to be
configured to reset automatically after a given time period.
Nice To Have
No
The ORION Cellular has a standard of 15-minute
intervals with a transmission rate of four times per
weekday and once per weekend day. Three of these
weekday transmissions are configurable by the City to
support business processes. These transmissions do not
automatically reset after a given time period but can be
reset manually at any given time.
This would include the entire fleet of endpoints and are
unable to change the transmissions times for individual
endpoints.
3.16
AMI Endpoints
Endpoints for different meter
types and installation
circumstances
The proposed Endpoint model shall accommodate different meter register manufacturers.
Must Have
Yes
3.17
AMI Endpoints
Multiple meters/registers
Endpoints shall optionally provide multiple ports to handle dual-register meters or ancillary
devices
Desired
No
The ORION endpoint does not include dual port
endpoint connections, but two endpoints can be
connected when two encoders are used.
3.18
AMI Endpoints
Number of digits
Endpoint shall transmit the same number of digits provided by the encoder register with no
truncation of data.
Must Have
Yes
3.19
AMI Endpoints
Other detection features
AMI endpoint shall report reverse flow alarms from the meter.
Must Have
Yes
3.20
AMI Endpoints
Other detection features
AMI system shall have the ability to accept other detection parameters from the meter,
such as pressure and temperature, and to transmit this via the data collector network to the
control computer.
Desired
Yes
3.21
AMI Endpoints
Other detection features
AMI shall provide interface units that connect to third party sensors (including but not
limited to water quality, temperature, pressure) through common interfaces such as 4-20
ma or MODBUS such that data are transmitted via the data collector network to the head-
end.
Nice To Have
Yes
Badger Meter offers Telog recording telemetry units
that enable the transmission of data from third party
sensors through a common backhaul device to Badger
Meter Software. These units are designed to collect
data from various sensors by recording its data
interface. Telog supports multiple data interfaces,
including Analog (4-20mA, 0-5 vdc), Digital
(Pulse/Relay), Encoder, or Modbus
3.22
AMI Endpoints
Pit Set Endpoints
Pit-set Endpoints shall meet performance requirements using an under-lid or through lid
installation with composite pit and vault lids
Must Have
Yes
3.23
AMI Endpoints
Programmability
The Endpoint shall be able to be initialized or programmed during or prior to field
installation.
Strongly Desired
Yes
ORION Cellular endpoints are pre-configured in the
factory to recognize the device they are connected to
and do not require field programming.
3.24
AMI Endpoints
Programmability
The system shall be capable of over the air reprogramming of an Endpoint. This
functionality should allow for all functions available via a programming handheld as well as
firmware upgrade.
Desired
Yes
3.25
AMI Endpoints
Programmability
Firmware updates shall be possible both over the air and in the field.
Must Have
Yes
3.26
AMI Endpoints
Programmability
AMI Endpoints shall be capable of being read via walk-by and drive-by devices in the event
of network issues, without the need for the mobile collector to have internet access.
Must Have
Yes
In the rare event the cellular communications network
fails the ORION Cellular endpoint is capable of
transmitting a mobile RF message to support a walk-by
method of collection.
3.27
AMI Endpoints
Programmability
Meter reading and Endpoint transmission intervals shall be configurable through remote
electronic communication with the Endpoint (including via two-way).
Desired
Yes
The ORION Cellular endpoint offers two-way
communication, however the endpoint collects as a
standard 15-minute intervals. The transmission of the
data is configurable for three of the four communication
call-ins per weekday.
3.28
AMI Endpoints
Tamper detection
The system shall provide tamper detection capability which, when the meter, Endpoint or
any wiring between components has been tampered with, shall cause a tamper message to
be immediately transmitted to the AMI software.
Must Have
Yes
3.29
AMI Endpoints
Water Proofing
Endpoints shall be provided in waterproof casing rates IP8 or better (submersion up to 1
meter of depth) in accordance with IP code, IEC standard 60529.
Must Have
Yes
Assumes that the writer intended to list IP68.
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
3.30
AMI Endpoints
Meter Reading Intervals
Endpoints shall provide for at least hourly interval meters reads.
Must Have
Yes
3.31
AMI Endpoints
Meter Reading Intervals
Endpoints shall provide for 15-minute interval data.
Nice To Have
Yes
3.32
AMI Endpoints
Meter Reading Intervals
The Endpoint shall support localized interval data history storage and retrieval for all
available measurements, with a minimum storage capacity of thirty-five (35) consecutive
days of hourly interval data. Describe the retrieval process.
Must Have
Yes
Using the Product Configuration Utility (PCU) software,
an infrared (IR) communication cable and Windows
tablet/laptop/handheld localized data retrieval is
available. Connect the IR communication device to the
endpoint, the the troubleshooting process can begin.
3.33
AMI Endpoints
Public Relations
The Endpoint shall NOT transmit any personally identifiable information.
Must Have
Yes
3.34
AMI Endpoints
RF Operation
The utility shall have the ability to configure priority-mode communications on individual
Endpoints.
Desired
No
The system provides for immediate notification when
high-priority system exceptions occur, based on the
utility’s identification of the high-priority exceptions in
BEACON, however, these notifications are for the entire
population of endpoints. Once programmed in BEACON,
when a high-priority status exception is reported to an
ORION Cellular endpoint, an immediate off-schedule
transmission from that endpoint will be triggered. This
enables prompt notification of the condition to the
utility so that corrective action may be taken
immediately, thereby removing any latency of a
standard radio transmission. For example, this
functionality is available for endpoint reported
conditions such as endpoint tamper (cut-wire) and
encoder communication error as well as for meter-
reported conditions such as meter exceeding max flow.
3.35
AMI Endpoints
Environmental tolerances
AMI endpoints shall operate over a temperature range of at least -30º F to 140º F, and a
humidity range of at least 0% to 100% non-condensing.
Must Have
Yes
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
4.1
Data Collection System
Backhaul
Collectors shall have the capability for redundant backhaul with automatic switchover.
Must Have
Not Applicable
Badger Meter's AMI solution leverages the current cellular
infrastructure
4.2
Data Collection System
Backhaul
The AMI system shall be able to use Fiber backhaul for primary and cellular backhaul for
secondary.
Desired
Not Applicable
Badger Meter's AMI solution leverages the current cellular
infrastructure
4.3
Data Collection System
Data Persistence
The Respondent's proposed hardware shall retain minimum of 30 days of data in event the
collector loses backhaul connectivity.
Must Have
Yes
Badger Meter's Cellular Orion end point retains 42 days of data
4.4
Data Collection System
Batteries
The AMI system shall have battery backup for all data collector components.
Must Have
Yes
4.5
Data Collection System
Communication to control
computer
Collectors shall have multiple network connectors including fiber optic, wireless
broadband/cellular, and ethernet.
Must Have
Not Applicable
Badger Meter's AMI solution leverages the current cellular
infrastructure
4.6
Data Collection System
Data transmission accuracy and
security
AMI system shall provide full end to end encryption at a minimum of AES-128 for all data
communicated between the Endpoint and data collectors, and the data collectors and the
system head-end. AMI Vendor to provide specific information about encryption methods
utilized, including encryption levels and standards.
Must Have
Yes
4.7
Data Collection System
Data transmission accuracy and
security
The AMI system shall provide the ability to disable and enable encryption when required to
support system maintenance and troubleshooting.
Desired
Not Applicable
Maintence and troubleshooting of the NaaS(Cellular AMI) is
included in Badger Meter's offering
4.8
Data Collection System
Data transmission accuracy and
security
Owner shall retain ownership of all system data and have full access to it at any and all times
to utilize or export to third parties as they see fit, even in a hosted environment.
Must Have
Yes
4.9
Data Collection System
Electrical Isolation
Data collector system equipment shall be electrically isolated to protect against power surges
or lightning strikes.
Must Have
Not Applicable
Badger Meter's AMI solution leverages the current cellular
infrastructure that has multiple layers of redundancy to protect
against power surges and lightning strikes
4.10
Data Collection System
Environmental tolerances
Data Collection Equipment shall operate over a temperature range of at least -30º F to 140º
F, and a humidity range of at least 0% to 100% non-condensing.
Must Have
Yes
4.11
Data Collection System
FCC compliance
All applicable AMI system components must comply with FCC regulations 47CFR §15
(regulations regarding unlicensed transmissions).
Must Have
Yes
4.12
Data Collection System
Intrusion Alarms
Proposed solution must support real-time flags for intrusion at AMI collector equipment sites.
This may include, but is not limited to, door open alarms and data access alarms.
Must Have
Yes
4.13
Data Collection System
Endpoint Coverage
The data collection network shall provide 100% coverage of all Endpoints with at least 1
collector.
Must Have
Yes
4.14
Data Collection System
Physical Data Interfaces
System shall provide password protected access to any physical data interfaces on the
equipment itself, shall be required along with documentation on updating and maintaining
the user access.
Desired
Yes
4.15
Data Collection System
Programming
Collectors shall be capable of interfacing with Owner's laptops for troubleshooting and
maintenance. Additionally, collectors must have a method for local interface that allows
download of data in the event of a backhaul failure.
Must Have
Not Applicable
Badger Meter's AMI solution leverages the current cellular
infrastructure
4.16
Data Collection System
Read Success Rate
Proposed solution shall consist of a sufficient number of data collectors and repeaters to
obtain at least one meter register reading within a three-day interval from at least 99.5% of
all meters on which the system is installed, to obtain at least one read per day from at least
99% of meters on which the system is installed, and to obtain at least 99% of all readings
taken hourly or at more frequent intervals, unless there are temporary physical barriers
beyond the control of the Owner or the Proposer.
Must Have
Yes
4.17
Data Collection System
Redundancy
The data collection network shall maintain at least a 2:1 coverage redundancy on no less than
100% of all endpoints.
Must Have
Not Applicable
Badger Meter's AMI solution leverages the current cellular
infrastructure
4.18
Data Collection System
Protecting Data
The system shall have a method that allows collectors to detect unauthorized access and
send an alert to head-end system.
Must Have
Yes
4.19
Data Collection System
Stored data system integrity
and security
The system shall have the capability to prevent loss of stored meter reading and meter alarm
data.
Must Have
Yes
4.20
Data Collection System
Time Synchronization
The proposed system shall support automatic Endpoint clock synchronization with Collectors
and the Head End System. Time synchronization of all elements in an AMI system is required,
which here means that the internal clocks on all devices shall be in synch to the single second
or better.
Must Have
Yes
4.21
Data Collection System
Time Synchronization
Time sync configurations shall be set before or when equipment is installed in the field.
Desired
Yes
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
5.1
Portable Interrogation, Field
Programming and Testing
Devices
Functions/modes of operation The unit shall be capable of reading and downloading data from the Endpoints.
Strongly Desired
Yes
5.2
Portable Interrogation, Field
Programming and Testing
Devices
Design - Registers
The programmer for meter register and encoder shall be ruggedized (able to stand up to field
environment and drops)
Desired
Yes
5.3
Portable Interrogation, Field
Programming and Testing
Devices
Functions/modes of operation
The unit shall be capable of programming the Endpoint with any information required for
operation and not pre-programmed at the factory. It shall be capable of providing
instructions to the Endpoint concerning the make, model and data protocol of the meter
being connected, should the Endpoint not be able to determine this itself.
Strongly Desired
Yes
5.4
Portable Interrogation, Field
Programming and Testing
Devices
Functions/modes of operation The handheld unit shall be able to program a programmable meter register.
Must Have
Yes
5.5
Portable Interrogation, Field
Programming and Testing
Devices
Mobile Meter Reading
System shall be capable of reading meters in both walk-by or mobile drive-by mode.
Must Have
Yes
Cellular-based AMI systems provide greater reliability
than is available in both mobile and traditional data-
collector based radio frequency (RF) systems. Thus, there
is limited, if any, need for mobile backup. In the event the
utility requires a mobile backup read, the use of a
handheld meter reading device can be utilized for mobile
reading purposes. Mobile reads would be completed by
having a meter reader walk by the location of the ORION
Cellular unit and gather the required endpoint reading to
be loaded into BEACON.
5.6
Portable Interrogation, Field
Programming and Testing
Devices
Bar code reader
The unit shall contain an integral optical character reader or other device or function to
capture meter and Endpoint numbers from bar codes or other machine readable information
contained attached to the units.
Strongly Desired
Yes
5.7
Portable Interrogation, Field
Programming and Testing
Devices
Data Loss Prevention
All units must ensure against accidental data loss in case of a dead battery.
Must Have
Yes
5.8
Portable Interrogation, Field
Programming and Testing
Devices
Encryption
Handheld shall have the ability to temporarily disable encryption on the endpoint if required
for maintenance without intervention from the head end for maintenance and configuration. Nice To Have
Yes
Badger Meter offers several handheld device options for
troubleshooting and mobile data collection for back-up
capabilities.
Additionally, the Badger Meter IR Communication Device
can be used to activate or inactivate the endpoint, verify
encoder connection, and confirm network
communication. This device can be used as a standalone
tool, or connected with the Product Configuration Utility
software via a handheld, tablet, or laptop.
5.9
Portable Interrogation, Field
Programming and Testing
Devices
Functions/modes of operation The unit shall remotely be able to locate and diagnose problems with a meter register or
Endpoint unless the system incorporates an alternate way to make such diagnoses.
Strongly Desired
Yes
5.10
Portable Interrogation, Field
Programming and Testing
Devices
Functions/modes of operation The unit shall be able to ascertain the condition or remaining life of the battery in an
Endpoint and the water meter register.
Strongly Desired
Yes
5.11
Portable Interrogation, Field
Programming and Testing
Devices
Functions/modes of operation The programming/installation field tool shall provide immediate feedback of Endpoint
programming success and signal strength to the network.
Must Have
Yes
5.12
Portable Interrogation, Field
Programming and Testing
Devices
Mobile Solution
Field applications shall be made available in Android, iOS, or Windows compatible installers
for use with the utility's own hardware.
Desired
Yes
5.13
Portable Interrogation, Field
Programming and Testing
Devices
Mobile Solution
Programming field tools shall support cellular and/or wireless connectivity.
Desired
Yes
5.14
Portable Interrogation, Field
Programming and Testing
Devices
Off-Line Operations
The field programmer shall be able to perform all functions without the need to be connected
to the internet.
Strongly Desired
Yes
5.15
Portable Interrogation, Field
Programming and Testing
Devices
Data Export
The field tool shall retain a log or have the capability to export programming and read history
in a common format.
Strongly Desired
Yes
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
6.1
AMI System Software
General
Any Proposer-supplied, on-premise database used to store and manage meter readings
must be a non-proprietary and SQL-compliant
Must Have
Not applicable
Our BEACON software is a cloud-based Software as a Service.
6.2
AMI System Software
General
The AMI system shall provide direct linking to system data to support the export of data via
either ODBC database connections or API connections.
Must Have
Yes
6.3
AMI System Software
General
The Respondent shall maintain and provide a detailed data dictionary and the full database
schema to the Owner.
Must Have
Yes
6.4
AMI System Software
General
The AMI system shall provide reports which detail all past and current two-way commands
including the user who initiated them, date stamps, their success rates, and data responses. Must Have
Yes
6.5
AMI System Software
General
Report formats shall be user-customizable with full access to all tables and fields, using a
built-in report writer or a third-party commercially available report writer that is included
with the control computer software. Reports must be able to be directed to a printer,
screen or locally accessible data file. The control computer software should enable users to
do ad hoc queries.
Desired
Yes
6.6
AMI System Software
General
The system shall maintain log files of application events (errors, warnings, etc.) including file
processing stats and scheduled events. These logs must be accessible and searchable via
the system interface.
Must Have
Yes
6.7
AMI System Software
General
AMI system shall allow user defined, multi-faceted role-based security levels for activities
within the system. Example: (Division Assignment + Role = permission/access)
Must Have
Yes
6.8
AMI System Software
General
System shall have the ability to enforce security by Active Directory (AD) group
memberships and support Single Sign-On across all applications.
Must Have
Yes
6.9
AMI System Software
Software-as-a-Service
Proposer shall maintain redundant and geographically dispersed data centers such as to
provide a backup site.
Must Have
Yes
6.10
AMI System Software
General
Vendor shall represent and warrant that the software, as delivered to the Owner, does not
contain any program code, virus, worm, trap door, back door, timer, or clock that would
erase data or programming or otherwise cause the software to become inoperable,
inaccessible, or incapable of being used in accordance with its user manuals, either
automatically, upon the occurrence of Licensor-selected conditions, or manually on the
command of a person.
Must Have
Yes
6.11
AMI System Software
Software-as-a-Service
Hosted services includes off-site backups and a restore/recovery process in cases where a
data center outage is for an extended time.
Must Have
Yes
6.12
AMI System Software
Software-as-a-Service
Hosted environments must be a Tier 1 Data center, maintain high availability architecture
and achieve at least 99.9% application uptime.
Must Have
Yes
6.13
AMI System Software
Software-as-a-Service
Hosted environment compliant with SOC Type II. Independent audit report must be
available upon request.
Must Have
Yes
6.14
AMI System Software
Software-as-a-Service
Hosting environment is certified to ISO 27001 and NIST 800-53
Must Have
Yes
6.15
AMI System Software
MDMS
The City requires that users in the Meter Data Management System be able to identify a
group of meters and customers from a map (by drawing a polygon or box) and output
consumption / metering data in a table format that can be exported to Excel.
Strongly Desired
Yes
6.16
AMI System Software
General
The AMI HES and/or the MDMS shall allow users to subscribe to emailed reports of all (or
specifically targeted) device alarms over user-defined periods (daily, weekly, monthly).
Strongly Desired
Yes
6.17
AMI System Software
General
A user-programmable scheduler agent shall be available to perform scripted actions related
to program operations and integrations.
Must Have
Yes
6.18
AMI System Software
Head End
The Headend software shall allow for access to all system data via database connection or
APIs.
Must Have
Yes
6.19
AMI System Software
Head End
The Head End system shall supply basic functionality for Endpoint management, alarm
management, two-way firmware upgrades and commands, network monitoring, and API-
based data integration.
Must Have
Yes
6.20
AMI System Software
Head End
The AMI Solution Head End must have sufficient data processing performance to support
hourly interval meter reading data updated multiple times per day from 100,000 water
meters
Must Have
Yes
6.21
AMI System Software
Head End
The AMI Solution Head End must have sufficient data processing performance to support
every 15 minute handling of 15 minute meter reading data from 100,000 water meters
Strongly Desired
Yes
6.22
AMI System Software
Head End
The AMI Solution Head End must have sufficient data storage to support 3 years worth of
hourly interval meter reading data from 100,000 water meters
Must Have
Yes
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
6.23
AMI System Software
Head End
The Head End system shall supply map visualizations to help the AMI system administer/
manage system performance and visualize alarms and notifications. Minimum requirements
are to see on a map:
Map data shall be exportable.
Must Have
Yes
6.24
AMI System Software
Head End
The software shall provide the user with reports of the current status and reading history of
individual accounts and selectable groups of accounts.
Must Have
Yes
6.25
AMI System Software
Head End
The software shall allow endpoints to be assigned to group en-mass or via an upload
process, in addition to adding endpoints to a group individually.
Desired
Yes
6.26
AMI System Software
Head End
The software shall be able to sort and list accounts and their meter reading data, and to
provide configurable sorting and filtering.
Must Have
Yes
6.27
AMI System Software
Head End
The AMI Solution shall manage the associated AMI network equipment providing
configurable reports on system status, health, throughput, and connectivity though all
levels of the network
Must Have
Yes
ORION Cellular NaaS eliminates many of the traditional fixed network
operating expenses such as infrastructure, or the need for designing,
permitting, installing, maintaining, troubleshooting, and supporting a
separate telecommunications network. Our ORION Cellular NaaS includes
endpoints that collect and transmit new 15-minute interval readings four
times per weekday and once per weekend day directly to cellular carriers'
communication towers into BEACON.
6.28
AMI System Software
Head End
The Head End system shall provide a performance dashboard that can be configured to
display key system metrics including but not limited to overall register read success rates,
individual daily register read success rates, overall interval read success, and average data
collector redundancy.
Must Have
Yes
6.29
AMI System Software
Head End
The AMI Solution shall have the capability for a utility user to enable proactive alerts
regarding system status, system health and other important system admin concerns.
Must Have
Yes
6.30
AMI System Software
Head End
Software shall (1) operate the control computer that interacts with other AMI system
components to obtain meter readings and perform all over the air communication (2)
manage the database of meter readings and other information, and (3) interface to the
Owners' and other information systems. These applications may be integrated or separate.
Must Have
Yes
6.31
AMI System Software
Head End
Time reported is configurable to report in local time in all software interfaces. Vendor is
responsible for time conversion to local time.
Must Have
Yes
6.32
AMI System Software
Head End
The AMI system shall be capable of relaying data from acoustic leak sensors through the
AMI network, and making it available for analysis and export via the user interface.
Strongly Desired
Yes
Badger Meter offers acoustic leak detection devices that use the same
cellular network as the ORION Cellular NaaS solution which would be
made available for analysis and export of data.
6.33
AMI System Software
Head End
The Headend shall provide an aggregated view of all parameters that have been
programmed into Endpoint, Register, and any other connected devices, with filtering
options to easily search for and export all devices sharing a common parameter (i.e.- alarm
thresholds, reading dials, resolution, etc.).
Must Have
Yes
6.34
AMI System Software
MDMS
The MDMS software shall provide a complete set of APIs for use accessing system data and
implementing integrations.
Must Have
Yes
6.35
AMI System Software
MDMS
The MDMS software shall allow for, at minimum, read-only access to all databases. The
Respondent shall provide updated database schemas for all software, both at time of
deployment and after each update.
Must Have
No
We do not allow direct access to the databases in our cloud-platform.
6.36
AMI System Software
MDMS
The AMI system shall provide leak alerts which indicate if there is an abnormal increase in
water consumption, if there is no time interval (e.g., at night) when the rate of consumption
is zero, or if there is a “running continuously” condition. Leak alert thresholds shall be
configurable.
Must Have
Yes
6.37
AMI System Software
MDMS
The MDMS shall supply basic functionality for reading data validation and editing, reporting
on alarms/reads/exceptions, delivery of billable reads to CIS, and long-term storage of all
reading and alarm data received from the Head End.
Must Have
Yes
6.38
AMI System Software
MDMS
The MDMS shall indicate when there is an extended period of no flow through the meter,
or an unusually low consumption over a regular reading interval and be able to provide a list
of daily, weekly, or monthly alarms via email to select users.
Must Have
Yes
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
6.39
AMI System Software
MDMS
The MDMS shall allow meters to be grouped into multiple different user-configurable
groups by the user for meter reading and data analysis. Examples of groups include routes,
customer types, billing cycle, pressure districts, and geographic areas. Grouping must be
able to managed in the User Interface, including adding and removing meters from the
group. The software shall allow endpoints to be assigned to group en-mass or via an upload
process, in addition to adding endpoints to a group individually.
Must Have
Yes
6.40
AMI System Software
MDMS
The MDMS shall provide the ability to create a Virtual Meter from a grouping of meters.
Virtual Meters shall sum the consumption for a grouping of meters and present the total
consumption in a report for each interval period.
Must Have
Yes
Virtual meters is on the development roadmap.
6.41
AMI System Software
MDMS
Virtual Meters must be able to be managed in the User Interface, including adding and
removing meters from the group. Meter shall be able to be assigned to multiple virtual
meters. The software shall allow endpoints to be assigned to virtual meters groups en-mass
or via an upload process, in addition to adding endpoints to a virtual meter group
individually.
Must Have
No
Virtual meters is on the development roadmap.
6.42
AMI System Software
MDMS
The MDMS shall provide geographic, non-revenue dashboards that compare water
production from SCADA against aggregated consumption from meter groups.
Desired
Yes
This is supported through BEACON's DMA feature.
6.43
AMI System Software
MDMS
The MDMS shall display other detection parameters gathered by the meter, including
temperature and pressure.
Strongly Desired
Yes
6.44
AMI System Software
MDMS
The MDMS shall flag and report any unauthorized usage, if the customer account record
indicates that service has been shut off.
Must Have
Yes
6.45
AMI System Software
MDMS
The MDMS shall display an aggregated view of all alarms received from devices, with
detailed history available for individual devices. The view(s) shall clearly differentiate
between active vs. historical alarms, and provide filtering and export options.
Must Have
Yes
6.46
AMI System Software
MDMS
The MDMS shall receive updated data from the Head End at the following minimum
frequencies: general alarms = 1 hour, critical alarms = immediate, reading data = twice per
day
Must Have
Yes
6.47
AMI System Software
MDMS
Validation and estimation processes in the MDMS shall function regardless of data import
method.
Must Have
Yes
6.48
AMI System Software
MDMS
The MDMS shall allow the option of applying multipliers to read values for display,
reporting, and export purposes. The system must support individual multipliers for each
meter record.
Must Have
No
6.49
AMI System Software
MDMS
Software shall identify accounts where usage violates temporary restrictions (e.g., apparent
outdoor irrigation usage during non-allowed times or days)
Must Have
Yes
6.50
AMI System Software
MDMS
MDMS shall identify irrigation usage from consumption patterns and time of use.
Desired
Yes
6.51
AMI System Software
Installation Management
System
Installation Management System must contain information about the meter exchange
including photographs.
Must Have
Work Order Management system contains information such as photos,
account ID, location, etc. See Schedule of Work submission for
screenshots and additional details
6.52
AMI System Software
Installation Management
System
Installation Management System must have a meter inventory management capabilities
which includes assignment of inventory in different statuses (in stock, quarantined, etc.)
and which must be accessible by Owner.
Must Have
Proposal includes digital inventory management sofware that shall serve
as centralized and realtime tracking tool for products. Utilizes barcode
scanning and interfaces with WOMS
6.53
AMI System Software
Installation Management
System
Installation Management System must have a configurable installation workflow such that
installers are guided with a prescribed installation procedure including photos and data to
be captured during the install
Must Have
Yes, this is a basic capability of the proposed WOMS. See Schedule of
Work for more information.
6.54
AMI System Software
Installation Management
System
Installation Management System must have the ability to status install with configurable
statuses (installed, escalated to utility, meter/service repair, etc.)
Must Have
Yes, this is a basic capability of the proposed WOMS.
6.55
AMI System Software
Installation Management
System
Installation Management System must have the capability for reporting or data exports on
the status of installation work
Must Have
Yes, this is a basic capability of the proposed WOMS.
6.56
AMI System Software
Installation Management
System
Installation Management System must have the capability to confirm customer
communications have been sent before the install is scheduled
Desired
Traditional mailed notifications will be sent and managed per RFP. Mailer
will contain QR code. All mailed accounts will be contained on
documented list with completed mailing dates.
6.57
AMI System Software
Customer Portal
Vendor shall provide a customer portal that displays interval usage information.
Must Have
Yes
6.58
AMI System Software
Customer Portal
Customer portal shall display usage information from the MDM after information has gone
through VEE Processing (measurements).
Desired
Yes
Data doesn’t go through a VEE process.
6.59
AMI System Software
Customer Portal
Customer portal shall support single sign on for City staff.
Desired
Yes
6.60
AMI System Software
Customer Portal
The Customer Portal shall have different interfaces for the utility user and the end customer
user. A utility user must be able to view the end customer view in the event they must
provide phone support to the end customer.
Must Have
Yes
6.61
AMI System Software
Customer Portal
End Customer interface must be compatible with commonly available devices, browsers,
and operating systems that a customer could use for the lifetime of the system.
Must Have
Yes
6.62
AMI System Software
Customer Portal
The End Customer user interface must be available for use on mobile devices, whether on a
mobile browser or separate application.
Must Have
Yes
6.63
AMI System Software
Customer Portal
The End Customer must be able to receive notifications through the Customer Portal
system, text and email.
Must Have
Yes
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
6.64
AMI System Software
Customer Portal
Portal shall provide customer-configurable threshold alerts based on meter consumption
data, notifying customers when they have exceeded their usage threshold.
Must Have
Yes
6.65
AMI System Software
Customer Portal
End Customer accounts must be able to have access to more than one meter under one
account.
Must Have
Yes
6.66
AMI System Software
Customer Portal
End Customer must be able to have access to more than one account under a single portal
user name.
Must Have
Yes
6.67
AMI System Software
Customer Portal
Customer portal shall be designed to be compliant with American with Disabilities Act web
accessibility guidelines and to meet the most current standards from the World Wide Web
Consortium's (W3C) Web Content Accessibility Guidelines (WCAG). Section 508
Must Have
Yes
ADA guidelines are leveraged in updates to the BEACON consumer portal.
The VertexOne Digital Suite currently adheres to the Web Content
Accessibility Guidelines 2.2, Level AA.
6.68
AMI System Software
Customer Portal
Customer portal shall have the capability to provide End Customer with notifications of high
and unusual patterns of water consumption.
Must Have
Yes
This is also supported with the optional VertexOne offering.
6.69
AMI System Software
Customer Portal
Customer portal shall alert customer via phone or text message of a suspected pipe burst.
Strongly Desired
Yes
A leak alrert can be configured aleting the customer of unusal water flow
which could be from a pipe burst. This is also supported with the optional
VertexOne offering.
6.70
AMI System Software
Customer Portal
Customer portal should provide water saving tips and tools to the End Customers, as
applicable based on customer usage consumption pattern and promotion of water saving
devices, etc.
Must Have
Yes
Badger Meter partilly complies with this requirement on the basis of
availability of affordability programs- but Badger Meter does not support
enrollment into these programs.
6.71
AMI System Software
Customer Portal
Customer portal shall be able to direct End Customer to water conservation and efficiency
programs available at City of Glendale or through third party
Strongly Desired
Yes
6.72
AMI System Software
Customer Portal
Customer portal shall be able to direct End Customer to availability and enrollment to
specific customer affordability programs.
Strongly Desired
Yes
6.73
AMI System Software
Customer Portal
Customer Portal shall provide End Customer the ability to set communication preference,
such as viewing information in English and Spanish
Must Have
Yes
6.74
AMI System Software
Customer Portal
Customer Portal shall provide the End Customer the ability to prepare printable consumer
water consumption reports that compares consumption to other customer groups (similar
to energy consumption reports).
Must Have
Yes
Supported by optional VertexOne offering.
6.75
AMI System Software
Customer Portal
Customer portal shall allow End Customer to make, modify, reschedule, or cancel online
payments or automatic payments.
Must Have
Yes
Supported by optional VertexOne offering.
6.76
AMI System Software
Customer Portal
Customer portal shall integrate with third-party payment applications.
Must Have
Yes
EyeOnWater can provide a link to your payment provider but does not
display bills directly. VertexOne currently has a pre-built integrations to
provide a seamless customer experience with your payment vendor,
Paymentus. With this integration, customers can make payments directly
from the VertexOne application. With Paymentus, VertexOne leverages a
fully integrated iFrame. Customers can pay through the Paymentus iFrame
without ever leaving the VertexOne Digital portal.
VertexOne solutions can further integrate with any third-party payment
solution capable of mapping to the VertexOne APIs.
6.77
AMI System Software
Customer Portal
Customer portal shall integrate with Paymentus for on-line payment processing functions.
Must Have
Yes
Please see the response to requirement 6.76, above. VertexOne has an
official partnership with Paymentus. There are approximately 40 live
clients leveraging the VertexOne / Paymentus integrated solution.
6.78
AMI System Software
Customer Portal
Customer portal shall provide customizable online audit for customers to self-diagnose high
water consumption.
Must Have
Yes
Supported by optional VertexOne offering.
6.79
AMI System Software
Customer Portal
Customer portal shall provide customers with analytics for understanding contributing
factors for high water consumption including detailed water consumption insights.
Must Have
Yes
Supported by optional VertexOne offering.
6.80
AMI System Software
Customer Portal
Customer portal shall provide end user ability to compare two or more billing periods.
Must Have
Yes
6.81
AMI System Software
Customer Portal
Customer portal shall provide end user ability to forecast or project future periods.
Must Have
Yes
Supported by optional VertexOne offering.
6.82
AMI System Software
Customer Portal
Portal must conform with design and style of corporate website and vendor must be able to
update the design and style in accordance with the latest Owner branding and
communication requirements.
Must Have
Yes
6.83
AMI System Software
Customer Portal
Customer portal must integrate with telephony and billing systems to enable customer to
contact customer service representatives through 'Click to Chat', 'Click to Call' or similar
links.
Strongly Desired
Yes
6.84
AMI System Software
Customer Portal
Customer portal must integrate with outage management systems and provide ability for
real time information and visual outage reporting using data and ArcGIS maps.
Strongly Desired
Yes
6.85
AMI System Software
Customer Portal
Capability to enroll in notifications/alerts based on communication preferences for no
additional cost including: Bill threshold alerts, bill available, bill due in x days, bill paid
including text, email.
Must Have
Yes
6.86
AMI System Software
Customer Portal
Ability for customers to initiate service orders via the customer portal. Service order to
integrate with NorthStar CIS for processing.
Strongly Desired
Yes
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
6.87
AMI System Software
Customer Portal
Ability to conduct customer surveys.
Desired
Yes
6.88
AMI System Software
Customer Portal
Ability to link to printable electronic copy of bill on the customer portal
Must Have
Yes
Supported by optional VertexOne offering.
6.89
AMI System Software
Customer Portal
Ability to have the bill message and newsletter available online via a customer portal.
Must Have
Yes
Supported by optional VertexOne offering.
6.90
AMI System Software
Customer Portal
Portal provides the ability to request service, including service connections, transfers,
disconnections, new customer move-in with deposit, etc.
Must Have
Yes
Supported by optional VertexOne offering.
6.91
AMI System Software
Customer Portal
Portal to provide updated account information, including current balances, payment
history, billable water usage, due dates, past due amounts, and shut off date, when
applicable.
Must Have
Yes
Supported by optional VertexOne offering.
6.92
AMI System Software
Customer Portal
Portal to provide ability to pay bill via credit card, debit card, and ACH.
Must Have
Yes
Supported by optional VertexOne offering.
6.93
AMI System Software
Customer Portal
Portal to provide ability to pay bill via advanced payment methods such as Google Pay,
Apply Pay, and Venmo
Desired
Yes
Supported by optional VertexOne offering.
6.94
AMI System Software
Customer Portal
Portal to provide links to a PDF renderings of the bill statement and any correspondence for
customer to download or print.
Must Have
Yes
Supported by optional VertexOne offering.
6.95
AMI System Software
Customer Portal
Portal provides ability to opt-in and opt-out of electronic billing, with an option to not
receive a paper bill. CIS and corresponding bill printing processes are updated automatically
based on changes made in the portal.
Must Have
Yes
Supported by optional VertexOne offering.
6.96
AMI System Software
Customer Portal
Portal provides a way to customers to request a payment extensions and payment plans,
based on eligibility rules.
Must Have
Yes
Supported by optional VertexOne offering.
6.97
AMI System Software
Customer Portal
Portal provides customer the ability to enroll or unenroll from automatic payment debiting,
either by credit card or bank account.
Must Have
Yes
Supported by optional VertexOne offering.
6.98
AMI System Software
Customer Portal
Ability to modify existing payment options, such as changing a credit card.
Must Have
Yes
Supported by optional VertexOne offering.
6.99
AMI System Software
Customer Portal
Ability to notify users if autopayment methods have expired/no longer usable. Notification
can happen through various communication channels.
Must Have
Yes
Supported by optional VertexOne offering.
6.100
AMI System Software
Customer Portal
Ability to send alerts in the customer portal. Alerting in the customer portal could be used
for new bill alert, or dunning.
Must Have
Yes
6.101
AMI System Software
Customer Portal
Portal should be flexible about hiding and displaying information tailored to Owner's needs. Must Have
Yes
Supported by optional VertexOne offering.
6.102
AMI System Software
Customer Portal
Customer portal shall display water consumption through interactive charts and graphs.
Must Have
Yes
6.103
AMI System Software
Customer Portal
Customer portal shall be PCI Compliant
Must Have
Yes
6.104
AMI System Software
Customer Portal
Portal utilizes interval data to estimate water usage types - i.e. breakdown of water use,
clothes washing, showing, etc.
Desired
Yes
6.105
AMI System Software
Customer Portal
Capable of encouraging water conservation such as customers can compare usage to typical Strongly Desired
Yes
6.106
AMI System Software
Customer Portal
End Customer notification from the Customer Portal must include alerts that the Owner can
push to all or targeted customers with specific attributes (e.g. consumption, location,
payment timeliness).
Must Have
Yes
Supported by optional VertexOne offering.
6.107
AMI System Software
Customer Portal
Portal allows the Owner to create a water budget based on each customer's household
characteristics and to display a comparison of actual usage compared to the water budget.
Strongly Desired
Yes
6.108
AMI System Software
Customer Portal
Portal can prompt customers to sign-up for water saving features when they sign-in to the
portal.
Desired
Yes
6.109
AMI System Software
Customer Portal
Portal can send a personalized customer sign-up link that does not require the customer to
look-up their account number to enroll in the portal.
Must Have
Yes
Supported by optional VertexOne offering.
6.110
AMI System Software
Customer Portal
Provide ability for customers to make account profile changes (email, phone, etc.) and then
pass these updates to the CIS
Must Have
Yes
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
7.1
System Integration
Integration
AMI head-end shall integrate with NorthStar CIS via standard and readily available APIs.
Must Have
Yes
7.2
System Integration
Integration
AMI head-end shall integrate with the Customer Portal via standard and readily available
APIs.
Must Have
Yes
BEACON and VertexOne solutions can both integrate with
the Northstar CIS via readilly avialbale APIs
7.3
System Integration
Integration
Customer portal shall integrate with Northstar CIS via standard and readily available APIs.
Must Have
Yes
BEACON and VertexOne solutions can both integrate with
the Northstar CIS via readilly avialbale APIs
7.4
System Integration
Integration
The MDMS shall receive and return meter level inquiry and commands to support NorthStar
CIS process integration for processes including but not limited to on-demand read,
disconnect, and soft-disconnect.
Must Have
Yes
In the monitoring section of BEACON, users will be able to
select individual accounts and create groups through
filters, giving the City the capability to select a date range
and interval of reads using the actions command and
export feature to fulfill this requirement. Additionally, the
ORION Cellular NaaS solution comes standard with four
daily communications per day of 15-minute interval data.
This means that the utility will always have fresh, sub-
daily reads to reference with customers and internal
operations. Three of the daily communications are
configurable and are typically scheduled every few hours
during business hours. This access enables utilities to
promptly detect and respond to irregularities or
anomalies, ultimately, making the need for reactive on-
demand readings less critical.
As the City sets the call-in schedule for the ORION Cellular
endpoints, BEACON can configure the system so that final
and special reads completed during standard office hours
are no more than six hours old, depending on the City’s
configurable schedule.
7.5
System Integration
Integration
MDMS shall send billing meter reads to NorthStar CIS.
Must Have
Yes
7.6
System Integration
Integration
AMI head end shall send meter events, including but not limited to register-level alarms
(leak, reverse flow, high flow, swapped meter, tamper, etc.) and endpoint events (low
battery, meter communication failed, non-numeric read, meter read malfunction, etc.) to
MDMS
Must Have
Yes
7.7
System Integration
Integration
AMI head-end and MDMS shall synchronize device information and master data with
NorthStar CIS, including but not limited to meter and Endpoint information.
Must Have
Yes
7.8
System Integration
APIs
AMI system software (including the headend, MDMS, and customer portal) shall integrate
with NorthStar CIS and other applicable City information systems via standard and readily
available APIs, which shall expose all pertinent AMI system data.
Must Have
Yes
Yes. Addtionally, the optional VertexOne add-on provides
standard APIs for each function enabled in their self-
service platform. VertexOne, optionally, can provide their
iPaaS middleware layer to map / translate the VertexOne
standard APIs to the available CIS APIs. VertexOne and
the AMI system are fully integrated.
7.9
System Integration
Customer Account Information
Update
As customer account information changes throughout each day in the NorthStar CIS, the
relationships between the meter, register and MIU and associated information in the
headend, MDMS, and Customer Portal need to stay in sync. This interface shall ensure that
when billing reads, consumption analysis, or alarms are identified in the AMI software, they
are associated to the correct customer and location.
Must Have
Yes
Yes. Additonally, the optional VertexOne add on pulls
Customer, Account and Billing data in real-time from the
CIS via standard APIs and pulls AMI data through standard
interfaces. Additionally, VertexOne updates thier
VXsmart analytics data warehouse daily to ensure data
currency for anlytics and reporting needs.
7.10
System Integration
Meter Read Request and
Response
Interface shall be a two-way interface between the MDMS and Northstar to request and
receive reads for billing.
Must Have
Yes
7.11
System Integration
Meter Exchange Completed
Workorder Data
Interface shall send the completed work order information back into the Northstar billing
system to manage meter installation and change out work orders so the CIS is up-to-date
after the work is completed. Interface shall contain all relevant information for the correct
automated creation of the installed water meter, including but not limited to meter model
and size information, read multipliers, meter dial configurations, meter and endpoint IDs,
and start/stop meter reads, service line materials of construction, etc.
Must Have
No
We largely believe that we can comply with this request,
and we've been engaged in active conversations with the
WOMs provider rep (InfraMap) and Northstar. Having
said that, we had some open coordination questions
about how data would map into Northstar. At the time of
this response we simply did not feel comfortable
signaling full compliance.
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)
7.12
System Integration
Interval Read Integration to
Northstar
AMI system shall provide interval meter read data to Northstar billing system via an
interface such that the interval meter reads and usage can be accessed via the Northstar
billing user interface without the need to separately access the AMI system software.
Must Have
Yes
7.13
System Integration
Automated Move-in/Move-Out
Move-in/Move-out meter reads (start reads and final reads) shall be initiated from
the Northstar user interface and obtained automatically from the MDMS via an
integration with the Northstar billing system without the needs access the AMI
system software.
Must Have
Yes
BEACON supports off-cycle billing reads through a
publicly documented REST API. The Northstar CIS would
need to implement this API to retrieve the billing read.
7.14
System Integration
Virtual Disconnect
Meters can be marked as virtually disconnected in the Northstar billing software and
updated as such in the MDMS automatically via an interface with the Northstar
billing software. The MDMS shall then alert to usage on the virtually shut account,
shall make these alerts available via a report from the AMI software, and shall pass
these alerts to the Northstar software via an interface such that they will display on
the appropriate accounts.
Must Have
Yes
Northstar must update BEACON with the virtually shut
account information. Northstar can then request reads
based on the accounts being virtuall shut. Alternatively,
BEACON could push any reads on virtuall shut meters to
Northstar, but this would require an extra line-item.
7.15
System Integration
Leak Alerts Integration to
Northstar
MDMS shall provide leak alerts to Northstar billing system software such that the
alert can be displayed on the customer account.
Must Have
Yes
Nothstar can request leak information from BEACON or,
with an extra line-item BEACON can push leak
information to Nortstar.
Requirement ID
Area
Sub-Area
Requirement Description
Priority
Ability to Meet Requirement
(Yes / No)
Comments
8.1
Support
Compliance
Vendor shall obtain all Federal, State and local permits required for the installation and
operation of the system and any other approvals.
Must Have
Yes
ORION Cellular NaaS eliminates many of the traditional
fixed network operating expenses such as infrastructure,
or the need for designing, permitting, installing,
maintaining, troubleshooting, and supporting a separate
telecommunications network. Our ORION Cellular NaaS
includes endpoints that collect and transmit new 15-
minute interval readings four times per weekday and once
per weekend day directly to cellular carriers'
communication towers into BEACON.
8.2
Support
Component firmware
Proposer shall include firmware for all system components, including Endpoints, DCUs and
portable interrogator/programming/testing units, at no additional cost or separate annual
maintenance fee. Additionally, all updates, including firmware, MUST include release notes
at every release.
Strongly Desired
Yes
8.3
Support
Component firmware
Proposer shall provide any available upgrades or patches to firmware to correct problems,
add new standard features, and ensure system compatibility and full functionality for a
minimum of 15 years or the expected life of the components at no additional cost, including
installation.
Strongly Desired
Yes
8.4
Support
Security
AMI System shall have third party vendor access to system prohibited unless allowed by
Owner's authorized personnel.
Strongly Desired
Yes
RFP 25-14 AMI REQUIREMENTS (ATTACHMENT B)