Site Plan

City of Glendale — Regular Meeting (2025-02-27)

View PDF Item 2 Meeting page

Extracted text (via pymupdf) 10006 characters
BELL ROAD
1
2
3
4
8
7
T
5
6
7
7
NEW
JACK IN THE BOX
RESTAURANT
6665 W. BELL ROAD
GLENDALE, AZ 85308
APN 200-51-847J
MK12B_SM
2,003 SF
6
EXISTING
WELLS FARGO
BANK
6695 W. BELL ROAD
GLENDALE, AZ 85308
APN 200-51-847D
STOP
70'
7 SPACES AT 10'-0" EACH
80'
8 SPACES AT 10'-0" EACH
40'
4 SPACES AT 10'-0" EACH
20'
2 SP. @ 10' EA.
11'
5'
11'
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
3
3
4
4
4
4
4
4
4
5
5
5
5
5
5
6
2
4
2
6
6
6
6
6
6
6
7
8
8
8
9
10
11
12
13
14
44
14
14
14
44
15
15
34
54
16
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
20
18
18
18
18
18
19
19
20
21
21
21
21
22
22
22
23
24
25
26
29
28
30
30
31
31
31
14
31
32
33
33
35
36
37
38
38
39
39
40
40
40
40
40
18
40
40
40
40
18
40
40
40
20'
18'-6"
20'
18'-6"
20'
18'-6"
20'
41
42
43
45
45
46
44
44
15
47
48
48
49
50
50
51
51
51
32
20
32
2
2
2
2
2
2
2
2
52
53
30'
3 SPACES AT 10'-0" EACH
N 87°31'26" E  126.87'
N 02°28'34" W  139.07'
N 02°18'53" W  139.08'
N 87°31'26" E  104.07'
C1
L1
27
15
0
20'
40'
10'
S C A L E :
1 A R C H I T E C T U R A L  S I T E  P L A N
1 "  =  2 0 ' - 0"
ARCHITECTURAL SITE PLAN KEYED NOTES
1.
EXISTING PROPERTY LINE TO REMAIN.
2.
EXISTING CONCRETE CURB TO REMAIN
3.
EXISTING SCREEN WALL TO REMAIN.
4.
EXISTING SIDEWALK TO REMAIN.
5.
EXISTING PARKING TO REMAIN. (NOT A PART)
6.
EXISTING LANDSCAPING TO REMAIN.
7.
EXISTING DRIVEWAY TO REMAIN.
8.
EXISTING DRIVE AISLE TO REMAIN.
9.
EXISTING TRANSFORMER LOCATION.
10.
PROPOSED ELECTRIC SERVICE ENTRY SECTION (SES). CONTRACTOR TO COORDINATE WITH THE
APPROPRIATE UTILITY PROVIDER. REFER TO ELECTRICAL DOCUMENTS.
11.
PROPOSED GAS METER LOCATION. CONTRACTOR TO COORDINATE WITH THE APPROPRIATE UTILITY
PROVIDER. BOLLARDS INSTALLED PER PROVIDER STANDARDS. REFER TO PLUMBING DOCUMENTS.
12.
INSTALL GREASE INTERCEPTOR. REFER TO CITY OF GLENDALE PRETREATMENT PROGRAM AND
PLUMBING DOCUMENTS.
13.
INSTALL CO₂ TANK WITH ENCLOSURE (UNDER SEPARATE SUBMITTAL/PERMIT BY OTHERS). gc SHALL
COORDINATE WITH CO₂ CONTRACTOR AND FIRE DEPARTMENT TO SECURE ALL REQUIRED DOCUMENTS
FOR SUBMITTAL/APPROVAL/PERMIT. REFER TO CO₂ NOTES ON SHEET TS1.1.
14.
INSTALL ASPHALTIC CONCRETE PAVING. REFER TO GEOTECHNICAL REPORT AND CIVIL DOCUMENTS.
15.
INSTALL BLACK INTEGRAL COLORED CONCRETE PAVING. REFER TO GEOTECHNICAL REPORT AND CIVIL
DOCUMENTS.
16.
INSTALL BLACK INTEGRAL COLORED CONCRETE APRON. PROVIDE THICKENED CONCRETE EDGE AT
PAVING INTERFACE. REFER TO DETAIL 6/SD2.0 AND CIVIL DOCUMENTS.
17.
CONSTRUCT CONCRETE CURB. REFER TO CIVIL DOCUMENTS.
18.
INSTALL 4-INCH (MIN) THICK CONCRETE SIDEWALK WITH LIGHT BROOM FINISH. REFER TO CIVIL
DOCUMENTS.
19.
CONSTRUCT FLARE SIDED (WINGED) CURB RAMP. REFER TO DETAILS 13/SD2.0,, 15/SD2.0 &
18/SD2.0
20.
CONSTRUCT IN-LINE CURB RAMP. REFER TO DETAILS 14/SD2.0, 15/SD2.0 & 18/SD2.0
21.
EXISTING LIGHT POLE BASE AND LIGHT POLE TO REMAIN.
22.
INSTALL BARRIER POSTS AT PREVIEW BOARD, MENU BOARD, AND PERIPHERAL TO BUILDING
CORNERS. REFER TO DETAIL 20/SD2.1.  CONTRACTOR TO PROVIDE SLEEVES THROUGH CURB AND
GUTTER WHERE APPROPRIATE. SEE SHEET A1.0 FOR DIMENSIONING CONTROL & BARRIERS
ADJACENT TO BUILDING.
23.
INSTALL DETECTOR LOOP FOR ORDER BOARD. REFER TO DETAIL 5/SD2.3.
24.
INSTALL DETECTOR LOOP AT PICK UP WINDOW. REFER TO DETAIL 3/SD2.3.
25.
INSTALL PREVIEW BOARD. REFER TO DETAILS 4/SD2.3, 6/SD2.3 & 16/SD2.4.
26.
INSTALL ORDER/SPEAKER BOARD AND WEATHER PROTECTION CANOPY. REFER TO DETAILS 5/SD2.3,
6/SD2.4, 7/SD2.4, 8/SD2.4 & 18/SD2.4.
27.
INSTALL SINGLE BAR HEIGHT CLEARANCE (9'-0") AND WARNING POLE SIGN UNDER SEPARATE
SUBMITTAL/PERMIT BY OTHERS. REFER TO DETAILS 7/SD2.3, 8/SD2.3 & 16/SD2.3.
28.
INSTALL ACCESSIBLE PARKING SIGN. REFER TO DETAILS 4/SD2.1 & 5/SD2.1.
29.
INSTALL ACCESSIBLE PARKING SIGN WITH 'VAN' PLACARD. REFER TO DETAILS 4/SD2.1 & 5/SD2.1.
30.
DEDICATED ONLINE ORDERING/DELIVERY PARKING STALL SIGN. REFER TO DETAIL 10/SD2.1. PAINT
PARKING STALL STRIPING AND CONCRETE WHEEL STOPS SHERWIN WILLIAMS SW 6832 "IMPULSIVE
PURPLE."
31.
PAINT 4-INCH SOLID TRAFFIC WHITE PARKING STRIPES.
32.
PAINT 4-INCH WIDE SOLID DIAGONAL LINES AT 2'-0" O.C. TRAFFIC YELLOW. REFER TO DETAIL
11/SD2.1
33.
PAINT ACCESSIBLE PARKING SYMBOLS. REFER TO DETAIL 8/SD2.1.
34.
DRIVE-THRU ARROW. PAINT SHERWIN WILLIAMS SW 6832 "IMPULSIVE PURPLE." REFER TO DETAIL
12/SD2.1.
35.
INSTALL U-BAR BIKE RACK. REFER TO DETAIL 4/SD2.2.
36.
INSTALL 6'-0" HIGH CONCRTE MASONRY UNIT REFUSE ENCLOSURE. REFER TO DETAILS ON SD2.2
PROVIDE A MINIMUIM 25' VERTICAL CLEARANCE OVER THE ACCESS AREA, AND 54' OF
UNOBSTRUCTED BACKING DISTANCE.
37.
PROVIDE TRASH RECEPTACLE WITH CHUTE ON SIDEWALK.
38.
APPLY INTERNATIONAL SYMBOL OF ACCESSIBILITY DECAL ON DOOR.
39.
PROVIDE MINIMUM 5'-0" WIDE UNOBSTRUCTED ACCESSIBLE PATH OF TRAVEL.
40.
PROVIDE LANDSCAPING. REFER TO LANDSCAPE DOCUMENTS.
41.
WALK UP WINDOW LOCATION
42.
PICK UP WINDOW LOCATION
43.
LINE OF PORTE COCHERE AT DRIVE THRU
44.
EXISTING ACCESS EASEMENT NO.93-0021658 TO REMAIN.
45.
EXISTING 18' INGRESS EGRESS EASEMENT NO.94-0360412 TO REMAIN.
46.
EXISTING 10' ELECTRICAL LINE EASEMENT NO.93-0045729 TO REMAIN.
47.
STAMPED ASPHALT DECORATIVE PAVING. REFER TO 9/SD2.1.
48.
FIRE TRUCK TURNING RADII (32'-6" INSIDE, 52'-6" OUTSIDE)
49.
PROPOSED REMOTE FDC (FIRE DEPARTMENT CONNECTION) LOCATION.
50.
FIRE LANE SIGN. REFER TO DETAILS 14/SD2.1 & 15/SD2.1
51.
EXISTING 15'-0" SETBACK TO REMAIN.
52.
EXISTING STREET IMPROVEMENTS TO REMAIN.
53.
PROVIDE 1'-0"W X 5'-6"L CONCRETE SPLASH BLOCK LOCATED INLINE WITH CANOPY ROOF DRAIN
OPENING ABOVE. REFER TO 20/SD2.0.
54.
PROVIDE 'STOP' PAVEMENT MARKING.
ARCHITECTURAL
SITE PLAN
SD1.0
AS NOTED
DxU
SITE DATA
DEVELOPER
STINE ENTERPRISES #107, LLC
10851 N. BLACK CANYON HIGHWAY, STE. 850
PHOENIX, ARIZONA  85029
PHONE: (602) 843-0530
CONTACT: STEVE STINE
EMAIL: steve@stineenterprises.com
A-2 (ASSEMBLY) RESTAURANT
6665 W. BELL ROAD, GLENDALE, ARIZONA  85308
VEHICLE PARKING REQUIRED: (COG UDC 35.4.05)
RESTAURANT W/ LIMITED SERVICE
1 SPACE PER 75 SF GFA
1 SPACE PER 400 SF OF OUTDOOR SEATING AREA
2,003 SF/75 SF = 27 VEHICLE PARKING SPACES REQUIRED
200-51-847J
C-2
REQUIRED: 240'-0"
PROVIDED: 140'-0"
TOTAL FLOOR AREA=
2,003 sf
TYPE V-B, FULLY SPRINKLERED
MAXIMUM ALLOWABLE BUILDING HEIGHT =
56'-0"
ACTUAL BUILDING HEIGHT =
24'-0"
SITE  AREA (NET): 18,077 sf (± 0.41 AC)
BICYCLE PARKING SPACES REQUIRED:
1 BICYCLE PARKING SPACES REQUIRED
BICYCLE PARKING SPACES PROVIDED:
4 BICYCLE SPACES @ 2'X6' EA. PROVIDED
VEHICLE PARKING PROVIDED:
28 VEHICLE PARKING SPACES PROVIDED
INCLUDES 1 STANDARD ACCESSIBLE +1 VAN ACCESSIBLE PARKING SPACE
BUILDING FORM AND LOCATION:
PARKING:
BUILDING CONSTRUCTION:
OCCUPANCY:
BUILDING AREA:
SITE AREA:
ZONING
ASSESSOR'S PARCEL NUMBER:
PROJECT ADDRESS:
PROPERTY OWNER
EGP GLENDALE OP II LLC
312 PLUM STREET, SUITE 875
CINCINNATI, OHIO 45202
PHONE:
(513) 713-0808
CONTACT:
ASHLEY MEYER
EMAIL:
ameyer@essentialgrowth.com
ARCHITECT
DXU ARCHITECTS
15150 N. HAYDEN ROAD, SUITE 225
SCOTTSDALE, ARIZONA  85260
PHONE: (623) 518-6857
CONTACT: JEFF LOOKER
EMAIL: jlooker@dxuarch.com
DRIVE-THRU QUEUING
VICINITY MAP
P.M. UPDATES:
9357 SPECTRUM CENTER BLVD
SAN DIEGO, CA 92123
c 2024 Jack in the Box Inc.
RELEASE:
SUBMITTAL DATE:
BID:
CONSTRUCTION:
SITE INFORMATION
REVISIONS
DATES
ADDRESS:
DRAWN BY:
SCALE:
PROJECT #:
BLDG TYPE:
JIB #:
1:
2:
3:
These designs, drawings and specifications
are the property of Jack in the Box Inc.
and shall not be copied or reproduced
without its previous written consent.
JANUARY, 2024
1638
6665 W. BELL ROAD
GLENDALE, AZ 85308
DxU
24-366
MK12B_SM
MK12B_SM
BELL ROAD
PARADISE LN.
75TH AVE.
GROVERS AVE.
59TH AVE.
63RD AVE.
GREENWAY RD.
THIS
PROJECT
67TH AVE.
CORPORATE OPERATIONAL STUDIES SHOW THAT TO MEET THE COMPANY
IMPOSED SERVICE DELIVERY TIMES PER VEHICLE, WITH A VEHICLE SIZE OF
10'-0" X 20'-0" UTILIZING A SINGLE DRIVE THRU LANE, SIX VEHICLES FROM
THE MENU BOARD AND SEVEN VEHICLES FROM THE PREVIEW BOARD TO
THE PICK-UP WINDOW, TOTALING 140'-0" OF QUEUING, IS THE OPTIMAL
QUEUING LENGTH REQUIRED.
QUEUING MEMORANDUM
15150 N.  Hayden Rd.   Suite 225   Scottsdale   Az   85260
 P:  4 8 0   6 2 6   9 5 0 2
© DxU 2024
These documents are confidential and shall
be in the possession of authorized
individuals only. These documents are the
exclusive property of DxU architects and
shall not be copied or reproduced without
written authorization.
R
E
G
IS
T
E
R
E
D
A
R
C
H
IT
E
C
T
A
R
IZ
O
N
A
U
.S
.A
.
Exp. 6/30/2026
20134
JEFF A.
LOOKER
D
A
T
E
S
IG
N
E
D
.
.
.
.
.
.
.
.
.
.
C
E
R
T
I
F
I
C
A
T
E
N
O
.
TRUE
NORTH
CITY OF GLENDALE SITE PLAN NOTES
a. FIRE DEPARTMENT ACCESS AND WATER SUPPLY REQUIREMENTS SHALL BE
IN PLACE PRIOR TO COMBUSTIBLE MATERIALS BEING BROUGHT ON SITE.
b. PURSUANT TO CHAPTER 32.5 OF THE GLENDALE CITY CODE, ALL NEW AND
EXISTING UTILITIES WITHIN OR CONTIGUOUS TO THIS SITE SHALL BE PLACED
UNDERGROUND.
c. ALL UTILITY BOXES, VAULTS AND BACKFLOW PREVENTION DEVICES SHALL
BE PAINTED TO MATCH THE BUILDING AND SCREENED FROM PUBLIC VIEW
BY A MASONRY WALL OR ROUND-TOPPED WIRE MESH ENCLOSURE, PAINTED
TO MATCH THE ADJACENT WALL.
d. SIGHT DISTANCE REQUIREMENTS OF COG DETAIL G-447 (LOCAL STREETS)
OR G-448 (ARTERIAL AND COLLECTOR STREETS) ARE MET FOR ALL
DRIVEWAYS AND STREETS.
e. STREETLIGHTS INSTALLED BY THE DEVELOPER MAY BE REQUIRED FOR
CONSTRUCTION PLAN APPROVAL.
f.
ON-SITE LIGHTING WILL BE PLACED SO AS TO DIRECT THE LIGHT AWAY
FROM ADJACENT RESIDENTIAL USES AND MUST NOT EXCEED ONE-FOOT
CANDLE AT THE PROPERTY LINE. THE HEIGHT OF THE PARKING LOT LIGHTS
WITHIN 150' OF RESIDENTIAL USE TO BE 15' HIGH PRESSURE SODIUM (HPS)
LIGHTING REQUIRED ADJACENT TO RESIDENCE.
g. ON-SITE LIGHTING SHALL MEET OUTDOOR LIGHT CONTROL ORDINANCE.
h. MAXIMUM NOISE LEVEL 55 DECIBLES (NORMAL SPEAKING VOICE) AT
PROPERTY LINE.
i.
CONVENIENCE USES SHALL BE SUBJECT TO A SEPARATE CITIZEN
PARTICIPATION AND CONDITIONAL USE PERMIT PROCESS.
j.
THE PROPERTY OWNER IS RESPONSIBLE FOR MAINTAINING LANDSCAPING IN
ALL PUBLIC RIGHTS-OF-WAY ADJACENT TO THE PROJECT.
PLAN
NORTH
TRUE
NORTH
Failed
BY
DATE
Conditionally Approved
Approved

Sydney Tirella
12/31/2024
City of Glendale
Development Services Department
Planning Division
CUP24-08 Conditionally Approved