Extracted text (via pymupdf)
4270 characters
20.0' 10.0' PROPOSED VETERINARY EMERGENCY GROUP (VEG) ±10,000 SF PROPERTY LINE W BELL RD EXISTING STREET LIGHT (TYP.) 30.0' 30.0' 30.0' 30.0' EXISTING FIRE HYDRANT EXISTING FIRE HYDRANT 7720 W BELL RD APN #200-43-006T LOJA GLENDALE LLC ZONING: PAD GNERAL PLAN: GC 7704 W BELL RD APN #200-43-006U SPIRIT SPE PORTFOLIO 2004 6 LLC ZONING: PAD GNERAL PLAN: GC 7708 W ARROWHEAD TOWNE CTR APN #200-43-011A PRASHANTH REDDY SEPARATE PROPERTY TRUST ZONING: PAD GNERAL PLAN: GC 7714 W BELL RD APN #200-43-012M GEN2 ARIZONA PROPERTIES LLC ZONING: PAD GNERAL PLAN: GC 7760 W BELL RD APN #200-43-012C ARROWHEAD STV LLC ZONING: PAD GNERAL PLAN: GC 7810 W BELL RD APN #200-43-012K WORLD TRAVEL INNS LIMITED PARTNERSHIP VI ZONING: PAD GNERAL PLAN: GC 7750 W ARROWHEAD TOWNE CTR APN #200-43-006P CTL PROPCO I LLC ZONING: PAD GNERAL PLAN: PC 7650 W ARROWHEAD TOWNE CTR APN #200-43-635 ARROWHEAD TOWNE CENTER LLC ZONING: PAD GNERAL PLAN: PC 23.0' EXISTING SIDEWALK EXISTING ADA STALLS SUITE BUILDING ENTRANCE APPROXIMATE LOCATION OF EGRESS DOOR SITE ACCESS POINT SITE ACCESS POINT SITE ACCESS POINT SITE ACCESS POINT W ARROWHEAD TOWNE CENTER 7720 W BELL RD VEG - GLENDALE PREPARED FOR VETERINARY EMERGENCY GROUP © PARKING SUMMARY USE REQUIRED EXISTING PROPOSED VEG (9,752 SF) VETERINARY HOSPITAL, EMERGENCY 25 - - SKECHERS (±18,000 SF) RETAIL, GENERAL 60 - - TOTAL 85 (4 ADA) 99 (12 ADA) 99 (12 ADA) (NO CHANGE) PROPERTY LINE LOCATION OF PROJECT (TENANT SPACE) LEGEND NOTES 1. AERIAL SHOWN DOWNLOADED FROM NEARMAP, CAPTURED NOVEMBER 15, 2024. 2. PARCEL DATA PROVIDED IN GIS FORMAT BY THE MARICOPA COUNTY GIS OPEN DATA, ACCESSED NOVEMBER 15, 2024. 3. ALL EXISTING FEATURES SHOWN ARE APPROXIMATE. 4. PARKING COUNT FROM NEARMAP AERIAL, CAPTURED NOVEMBER 15, 2024. 5. FIRE DEPARTMENT ACCESS AND WATER SUPPLY REQUIREMENTS SHALL BE IN PLACE PRIOR TO COMBUSTIBLE MATERIALS BEING BROUGHT ON SITE. 6. PURSUANT TO CHAPTER 32.5 OF THE GLENDALE CITY CODE, ALL NEW AND EXISTING UTILITIES WITHIN OR CONTIGUOUS TO THIS SITE SHALL BE PLACED UNDERGROUND. 7. ALL UTILITY BOXES, VAULTS AND BACKFLOW PREVENTION DEVICES SHALL BE PAINTED TO MATCH THE BUILDING AND SCREENED FROM PUBLIC VIEW BY A MASONRY WALL OR A ROUND-TOPPED WIRE MESH ENCLOSURE, PAINTED TO MATCH THE ADJACENT WALL. 8. SIGHT DISTANCE REQUIREMENTS OF COG DETAIL G-447 (LOCAL STREETS) OR G-448 (ARTERIAL AND COLLECTOR STREETS) ARE MET FOR ALL DRIVEWAYS AND STREETS. 9. STREETLIGHTS INSTALLED BY THE DEVELOPER MAY BE REQUIRED FOR CONSTRUCTION PLAN APPROVAL. 10. ON-SITE LIGHTING WILL BE PLACED SO AS TO DIRECT THE LIGHT AWAY FROM ADJACENT RESIDENTIAL USES AND MUST NOT EXCEED ONE-FOOT CANDLE AT THE PROPERTY LINE. THE HEIGHT OF THE PARKING LOT LIGHTS WITHIN 150’ OF RESIDENTIAL USE TO BE 15’. HIGH PRESSURE SODIUM (HPS) LIGHTING REQUIRED ADJACENT TO RESIDENCE. 11. ON-SITE LIGHTING SHALL MEET OUTDOOR LIGHT CONTROL ORDINANCE. 12. MAXIMUM NOISE LEVEL 55 DECIBELS (NORMAL SPEAKING VOICE) AT PROPERTY LINE. 13. CONVENIENCE USES SHALL BE SUBJECT TO A SEPARATE CITIZEN PARTICIPATION AND CONDITIONAL USE PERMIT PROCESS. 14. THE PROPERTY OWNER IS RESPONSIBLE FOR MAINTAINING LANDSCAPING IN ALL PUBLIC RIGHTS-OF-WAY ADJACENT TO THE PROJECT. 15. THE FOLLOWING I-CODES APPY TO THIS PROJECT: · 2018 INTERNATIONAL BUILDING CODE (IBC) · 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) · 2018 INTERNATIONAL MECHANICAL CODE (IMC) · 2018 NFPA 101 LIFE SAFETY CODE · 2018 INTERNATIONAL PLUMBING CODE (IPC) · 2018 INTERNATIONAL FIRE CODE (IFC) · 2018 INTERNATIONAL FUEL CODE (IFC) · 2017 NATIONAL ELECTRICAL CODE (NEC) · 2018 INTERNATIONAL ENERGY CODE (IECC) · 2010 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 1 SITE PLAN EXHIBIT NORTH VICINITY MAP 1" = 500' NORTH SITE W BELL RD N 77TH AVE N 79TH AVE CUP25-01 ZONING TABULATION PROPOSED USE VETERINARY HOSPITAL, EMERGENCY ZONING PLANNED AREA DEVELOPMENT (PAD) SITE AREA 117,438 SF / 2.696 AC BUILDING LOT COVERAGE 28,000 SF 0.24 BUILDING AREA ±0.64 AC (NO CHANGE FROM EXISTING) NET LANDSCAPED AREA ±0.45 AC (NO CHANGE FROM EXISTING) PROJECT DATA CONSTRUCTION TYPE IIB OCCUPANCY GROUP B - BUSINESS AND S - STORAGE. OCCUPANCIES TO BE SEPARATED BY 1-HR RATED DEMISING WALL. CALCULATION OF OCCUPANCY B - BUSINESS: 43 S - STORAGE: 11 TYPE OF SPRINKLER SYSYEM NFPA-13 (EXISTING) CUP25-01 VEG Glendale March 5, 2025