Site Plan

City of Glendale — Regular Meeting (2025-06-26)

View PDF Item 1 Meeting page

Extracted text (via pymupdf) 9527 characters
EXIT
EXIT
SAHUARO GLENN
(6) ACADEMY  
PARKING,
RESTRIPE 
PARKING 
SPACES
9'X18' EACH
NORTH
OUTDOOR PLAY AREA 
3,750 SF
SLUMP BLOCK FENCE 
PER DETAILS 2,3,4,&
5/G1.00
EXIT
EXIT
EXIT
EXIT
EXIT
VAN
ACCESS 
1
2
3
4
5
6
7
8
(E) FH
(E) FH
G1.00
8
EXIT
EXIT
EXISTING TRANSFORMER
9
10
11
12
14
15
16
17
13
18
19
20
GATE
G1.00
3
G1.00
5
EXISTING 
SITE FENCE
STAFF PATIO
UTILITY ENCLOSURE
UTILITY ENCLOSURE
W ALICE AVE
N 65TH AVE
(12) 
EXISTING 
PARKING 
-NO 
CHANGE 
PROPOSED
5' WIDE CONCRETE 
SIDEWALK, TYP
CONCRETE SIDEWALK, TYP
PROTECT EXISTING TREE
PROTECT EXISTING TREES
PROTECT EXISTING TREE
POST AND PANEL SIGN, NIC
G1.00
4
2
EXCAVATE 6"
145'-0"
(E) FH
EXISTING SITE GATE
TO EXIT (TO REMAIN OPEN)
PROTECT EXISTING TREES
NSSP
N
N
N
N
N
G1.00
7
4'-0"
EXISTING    RIGHT - OF - WAY
SHADE STRUCTURE 
10'X10'
SHADE STRUCTURE 
10'X10'
STORAGE SHED
120SFT ,  HT < 6'
PER IFC APPENDIX D, D103.4 DEAD 
ENDS , DEAD-END FIRE APPARATUS 
ACCESS ROADS WITHIN 150 DO NOT 
REQUIRE A TURNAROUND 
FIRE APPARATUS ACCESS ROAD <150 FEET
125'-0"
HOSE PULL DISTANCE
98'-8 1/2"
PROPERTY LINE
PROPERTY LINE
HOSE PULL 268' DISTANCE BETWEEN TWO FIRE ACCESS POINTS 
<300' (150'+150' HOSE PULL LENGTHS)  
EXISTING SIDE WALK FLUSH 
WITH DRIVE. NO CURB
COVERED 
PARKING TO BE 
MAINTAINED
(1) BIKE RACK - COLOR TO 
MATCH EXISTING BUILDING
ACCESSIBLE PATH TO 
PARKING: TEACHER WALKS 
KIDS ON CROSSWALK 
NORTH
G1.00.
8
G1.00.
3
G1.00.
4
G1.00.
2
G1.00.
7
G1.02
3
G1.02
2
G1.02
5
PARENT/GUARDIAN 
DROP OFF AND PICK UP: 
SEE NARRATIVE FOR 
OPERATIONS.
ASPHALT DRIVEWAY
28'-0"
DROP OFF
EXISTING SITE GATE
TO ENTER (TO REMAIN OPEN)
DRIVE AISLE CENTER LINE 
STRIPING
5'-0"
PROPOSED 
DRIVE LINE
STAFF ESCORTS 
STUDENTS TO 
CLASSROOM
CAR EXITS
CAR STOPS HERE 
AND KID GETS 
OUT HERE INTO 
TEACHER'S CARE
PARKING 
FOR 
TEACHERS 
AND 
PARENTS
PARKING 
FOR 
TEACHERS 
ONLY
PROJECT ADDRESS:
SAHUARO GLENN
6511 WEST ALICE AVENUE
GLENDALE, AZ 85302
   
OWNER: 
DAY 1 ACADEMIES
3040 78TH AVENUE SOUTHEAST, SUITE 1042
MERCER ISLAND, WA 98040
CONTACT: WOLFGANG HORN, PHONE 925-922-2268
PROPERTY OWNER:
GLENCROFT CENTER FOR MODERN AGING
8611 N 67TH AVE, GLENDALE, AZ 85302
GLENDALE, AZ 85302
CONTACT: JOHN THORNHAUER, PHONE 623-939-9475
   
ARCHITECT OF RECORD:
BASSETTI ARCHITECTS
71 COLUMBIA ST., #501
SEATTLE, WA 98104
CONTACT: SUSAN CONWAY, 206-340-9500
   
TAX PARCEL NO:
143-19-001M; 143-19-003A; 143-19-001L
   
LEGAL DESCRIPTION:
143-19-003A
W 50F SE4 NW4 EX S 40F & EX RD P/D 15171-148 & EX ANY PT LY SLY OF FOL DESC 
LN COM W4 COR SEC 31 TH N 88D 32M E 1220.8F N 384F S 88D 9M W 543F TH N 1D 
8M W 281.60F TO TPOB SD LN TH N 88D 51M E 549.87F TO TERM SD LN
143-19-001M
SE4 NW4 SEC 31 DAF FR NW COR SE4 NW4 SD SEC E 50F TPOB TH E 65. 96F TH S 
1320F M/L TH W 63.32F TH N 1320F TPOB EX S 40F & EX S 5X5 TRI IN SE COR & EX 
RD P/D 15171-148 & EX PT LY SLY OF FOL DESC LN COM W4 COR SEC 31 TH N 88D 
32M E 1220.8F N 384F S 88D 9M W 543F N 1D 8M W 281.60F TO TPOB SD LN TH N 88D 
51M E 549.87F TO TERM SD LN
143-19-001L
N2 SW4 NW4 SEC 31 AKA N2 LOT 2 EX W 45F & EX N 30F & EX 10F X 10F TRI IN NW 
COR TH/OF & EX COM W4 COR SEC TH N ALG W LN SEC 935.08F TH N 88D 51M E 
142.34F TH N 88D 37M E 384.19F TO TPOB TH CONT N 88D 37M E 142F TH S 1D 12M E 
213.58F TH S 88D 51M W 142F TH N 1D 12M W 213.01F TO TPOB & EX P/D 15491-0629
JURISDICTION:
CITY OF GLENDALE, AZ
   
FIRE DISTRICT:
GLENDALE FIRE DEPARTMENT   
SEWER DISTRICT:
GLENDALE SEWER SERVICES DEPARTMENT
WATER DISTRICT:
GLENDALE WATER SERVICES DEPARTMENT
   
CODES:
2018 IBC (International Building Code)
2018 IEBC (International Existing Building Code)
2018 IRC (International Residential Code)
2018 IMC (International Mechanical Code)
2018 IPC (International Plumbing Code)
2018 IECC (International Energy Code)
2018 IFGC (International Fuel Code)
2018 IFC (International Fire Code)
2017 NEC (National Electric Code)
Americans With Disability Act Accessibility Guidelines
Arizonans with Disabilities Act
2018 Americans with Disabilities Act Standards for Accessible Design
2018 IPMC (International Property Maintenance Code)
City of Glendale Revised Sound Attenuation Standards
Fair Housing Accessibility Guidelines
   
PROPOSED USE:
PRIVATE SCHOOL WITHOUT DORMITORIES  
   
ZONING:
R-4, MULTIPLE RESIDENCE
OCCUPANCY GROUP:
E - EDUCATIONAL - PERMITED CONDITIONAL USE
BUILDING AREA :
7,719 SF
N 59 TH AVE
N 67 TH AVE
W OLIVE AVE
W NORTHERN AVE
60
17
107
SITE LOCATION
NEW RIVER
NORTH
N 65 TH AVE
W ALICE AVE
EXISTING ACCESSIBLE PATH
CONCRETE SIDEWALK, TYP
BROOM FINISH, TOOLED CONTROL 
JOINT EVERY 5'-0"
(E) SEWER LINE
(E) WATER LINE
(E) FIRE HYDRANT (FH)
(E) LUMINAR
NO STANDING/STOPPING/PARKING SIGN
PER CITY OF GLENDALE TRANSPORTATION 
REFER DETAIL #SS-109
R7-101, R7-101L OR R7-101R
NSSP
ACCESSIBLE PATH
PROPERTY LINE
FIRE APPARATUS ACCESS ROAD
4
GATE-B-2
323119 - STL PICKET FENCE
042000 - MASONRY SLUMP BLOCK FENCE
G1.00
9
TYP
323119 - STL PICKET GATE
CJ
8'-0"
7'-9"
CJ
CJ
LEVEL 1
0"
4
GATE-B-1
6
G1.00
CJ
G1.00
3
TYP
SLUMP BLOCK MASONRY FENCE TO MATCH EXISTING SITE FENCE
8'-0"
7'-11 1/2"
LEVEL 1
0"
SECTION 033053 -
MISCELLANEOUS
CAST-IN-PLACE CONCRETE
3'-0"
323119 - FENCE POST 
MOUNTED ONE COURSE 
BELOW TOP OF WALL
323119 - STEEL PICKET FENCE
3'-4"
EQUAL TO (8) COURSES SB-CMU
2'-8"
EQUAL TO (4) COURSES SB-CMU
1'-4"
CIP FOOTING
9 1/4"
CAULKING AND 
BACKER-ROD
042000 - SLUMP WALL 
CONCRETE MASONRY UNITS
CUT BLOCK AROUND FENCE 
POST, LEAVE 1/4" VOID 
SPACE AROUND POST
042000 #5 @ 32" OC VERT
042000 #5 @ 48" OC HORIZ
033053 #5 DOWELS @16" OC 
(ALT. HOOKS)
#4 @ 48" OC TOP
(3) #4 CONT BOT.
EQ
8" MON
EQ
042000 #5 @ TOP
POST BASE PL, WELDED TO 
POST, 5X10X3/8 PL, (4) 3X1/2 
WEDGE ANCHORS
072500 - CAULKING AND BACKER ROD
323119 - STL PICKET 4X4X1/4 POST
GROUT FILLED 
CUT CMU TOP BLK
323119 - STL BASE PLATE
ACCESS PARKING SYMBOL 
PER #SS-205,WHITE
10'-0"
5'-0"
5'-0"
ACCESS PARKING SIGN REFER DETAIL #SS-105
#SS-131 FOR SIGN SQUARE POST
SECTION 321723 - 4" WIDE 
PAVEMENT MARKINGS, 
45DEG ANGLE 2' OC
4" WIDE WHITE PARKING STRIPE
WHEEL STOP
20'-0"
FLUSH CURB FROM PARKING TO 
SIDEWALK 
EXISTING TRANSFORMER
TRENCH PER ELECTRICAL DRAWINGS 
CONCRETE PATH, CONTROL JOINT 5' TYP
ELECTRICAL SERVICE LOCATION, 
SEE ELECTRICAL DRAWINGS
EXISTING BUILDING 
CONTROL JOINT TYP
G1.02
1
LEVEL 1
0"
CJ
CJ
CJ
323119 - STEEL PICKET
042000 - SLUMP BLOCK WALL
2'-8"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
2'-6"
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
CJ
LEVEL 1
0"
ACCESS PARKING SYMBOL 
PER #SS-205,WHITE
5'-0"
11'-0"
5'-0"
SECTION 321723 - 4" WIDE 
PAVEMENT MARKINGS, 
45DEG ANGLE 2' OC
VAN ACCESSIBLE SIGN
REFER DETAIL #SS-105
&SS-131 FOR SIGN SQUARE POST 
4" WIDE WHITE 
PARKING STRIPE
WHEEL STOP
VAN SPACE
FLUSH CURB FROM PARKING TO 
SIDEWALK 
20'-0"
3'-10"
1'-6"
a. Fire Department access and water supply requirements shall be in place prior to 
combustible materials being brought on site 
b. Pursuant to Chapter 32.5 of the Glendale City Code, all new and existing utilities 
within or contiguous to this site shall be placed underground. 
c. 
All utility boxes, vaults and backflow prevention devices shall be painted to match 
the building and screened from public view by a masonry wall or a round-topped 
wire mesh enclosure, painted to match the adjacent wall. 
d. Sight distance requirements of COG detail G-447 (Local Streets) or G-448 
(Arterial and Collector Streets) are met for all driveways and streets. 
e. Streetlights installed by the developer may be required for construction plan 
approval. 
f. 
On-site lighting will be placed so as to direct the light away from adjacent 
residential uses and must not exceed one-foot candle at the property line. The 
height of the parking lot lights within 150’ of residential use to be 15’.  High 
Pressure Sodium (HPS) lighting required adjacent to residence. 
g. On-site lighting shall meet outdoor Light Control Ordinance. 
h. Maximum noise level 55 decibels (normal speaking voice) at property line. 
i. 
Convenience uses shall be subject to a separate Citizen 
Participation and Conditional Use Permit Process. 
j. 
The property owner is responsible for maintaining landscaping in all  public rights-
of-way adjacent to the project. 
EXIT/ENTRANCE
EXIT/ENTRANCE
EXIT/ENTRANCE
ENTRANCE 
ONLY
EXIT 
ONLY
EXIT 
ONLY
71 Columbia Street, Suite 500
Seattle, Washington 98104
T (206) 340 9500
ISSUE DATE:
JOB NO:
#
DATE
Jurisdiction Stamp Area
ONE INCH
AT FULL SIZE
www.bassettiarch.com
4/21/2025 3:46:32 PM
ARCHITECTURAL
SITE PLAN
2314
GLENDALE -
SAHUARO
GLENN
BEZOS ACADEMY
APRIL 21, 2025
G1.00
SR24-0217 CUP
6511 WEST ALICE AVENUE
GLENDALE, AZ 85302
STRUCTURAL ENGINEER
Coughlin Porter Lundeen
801 Second Avenue Suite 900
Seattle, WA 98104
T (206) 343 0460
MECHANICAL ENGINEER
Hargis Engineers, Inc.
1201 3rd Avenue, Suite 600
Seattle, WA 98101
T (206) 448 3376
ELECTRICAL ENGINEER
Hargis Engineers, Inc.
1201 3rd Avenue, Suite 600
Seattle, WA 98101
T (206) 448 3376
1" = 30'-0"
1
SITE PLAN
PROJECT DATA
VICINITY MAP
SITE PLAN LEGEND
0'
30'
15'
1/4" = 1'-0"
3
72" NORTH GATE
1/4" = 1'-0"
5
72" SOUTH GATE
1 1/2" = 1'-0"
6
SITE WALL SECTION (TYP)
1 1/2" = 1'-0"
9
SITE WALL CONTROL JOINT (CJ) - TYP
1" = 10'-0"
8
ADA PARKING
1/16" = 1'-0"
10
SIDEWALK REPAIR
ACCESS PARKING SYMBOL
1/4" = 1'-0"
4
FENCE EAST ELEVATION
1/4" = 1'-0"
2
FENCE NORTH
1" = 10'-0"
7
ADA PARKING -VAN ACCESSIBLE
1
1
1
1
1
1
GENERAL SITE PLAN NOTES
2
REVISIONS
1
CUP RESPONSES
12/16/24
2
CUP RESPONSES
2/21/25
3
CUP RESPONSES
4/11/25
4
CUP RESPONSES
4/21/25
EXISTING PARKING EXITS / ENTRANCES
3
3
4
4
4
4
Received
4/24/2025