Extracted text (via ocr_local)
9668 characters
G E N E RAL N OT E S DEVELOPMENT OF A NEW DUTCH BROS AND SLIDERS BUILDING WITH P ROJ E CT T EAM . 3 EXTERIOR PATIO AND FULL SITE DEVELOPMENT. tu 1. ALL UTILITY LINES LESS THAN 69 KV ON OR CONTIGUOUS TO THE SITE SHALL OWNER: C IVIL: E BE INSTALLED OR RELOCATED UNDERGROUND. . a8y 2. ALL TRASH ENCLOSURES SHALL INCLUDE FULLY OPAQUE SCREENING GATES, . “a FINISHED AND PAINTED TO MATCH THE ENCLOSURE. SCREENING GATES CVP-NORTHERN HELIX ENGINEERING, 38 S SHALL NOT OPEN INTO VEHICULAR DRIVE AISLES. TRASH ENCLOSURES ARE AZ, LLC LLC zak NOT REQUIRED IN INDUSTRIAL DISTRICTS IF LOCATED INSIDE AN ENCLOSED : & on YARD WHICH IS SCREENED BY A PERIMETER WALL AT LEAST 6 FEET IN 2188 SW PARK PLACE, SUITE 100 3240 EAST UNION HILLS DR. #113 zae HEIGHT. PORTLAND, OR 97205 PHOENIX, ARIZONA 85050 5 <u 3. ALL OUTDOOR STORAGE AREAS FOR STORAGE OF MATERIALS AND PARCEL NUMBER: 143-16-051 PARCEL NUMBER: 143-16-052 PARCEL NUMBER: 143-16-053 PARCEL NUMBER: 143-16-054 CONTACT: MITCHELL REYNOLDS CONTACT: STEVE BOWSER. PE Oc 5 EQUIPMENT SHALL BE FULLY SCREENED FROM VIEW BY A 6’ SOLID MASONRY ZONING: R1-6 USE: RESIDENTIAL ZONING: R1-6 USE: RESIDENTIAL ZONING: R1-6 USE: RESIDENTIAL ZONING: R1-6 USE: RESIDENTIAL PH: (918) 934.0288 PH: (602) 788-2616 oe. oo = WALL. INDUSTRIAL STORAGE SCREEN WALLS SHALL BE FINISHED WHERE por ; ; ; Q= THEY ARE EXPOSED TO PUBLIC VIEW FROM STREETS OR ADJACENT 104'-1 1/2" i NON-INDUSTRIAL USES. 413-7 1/2" ARCHITECT: LANDSCAPE: B 4. S.E.S. PANELS AND ANY OTHER ABOVE GROUND UTILITY CABINET SHALL BE naa'49’0s"E | 217.74 . % FULLY SCREENED FROM VIEW FROM STREETS OR FROM AREAS ACCESSIBLE : ee = ——— TO CUSTOMERS AND THE GENERAL PUBLIC. SCREENING MAY BE po Dee ee ee = rn PH NX DESIGN, LLC H | LLMAN WORKSHOP ACCOMPLISHED BY ANY ONE OF THE FOLLOWING METHODS: a _ ol. @/ 1855 EAST SOUTHERN AVE, SUITE 204 2901 E. HIGHLAND AVE. A. FULLY RECESSING THE CABINET INTO THE BUILDING AND ENCLOSING IT BY A Ww 30 38 aele (30) (28) MESA, ARIZONA 85204 PHOENIX, AZ 85016 SOLID DOOR OR DOORS SEPARATE FROM THE CABINET; E 3 Be CONTACT: MIKE HILLS CONTACT: AARON HILLMAN B. SCREENING WITH A DECORATIVE MASONRY WALL OF THE SAME HEIGHT AS < 34 5 PH: (602) 762.7354 PH: (480) 686.2001 THE PANEL. THE SCREEN WALL MAY BE L-SHAPED, U-SHAPED OR A STRAIGHT o EMAIL: MIKEH@PHNX-DESIGN.COM WALL PARALLEL TO THE CABINET, DEPENDING ON THE LOCATION OF THE = 19 CABINET; © = C. AN ALTERNATIVE SCREENING METHOD APPROVED BY THE PLANNING ~ | 27 s 8 13 S | T EF D AT A DEPARTMENT PRIOR TO ISSUANCE OF ANY PERMITS. 5. THE LOCATION OF ALL ELECTRICAL UTILITY EQUIPMENT SHALL BE IDENTIFIED j ON THE CONSTRUCTION PLANS. | 2 22 APN: 143-16-003D 6. ROOF-MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY 13 2y)> NET SITE AREA: 60,547 S.F. (1.39 AC) EITHER ONE OF THE FOLLOWING METHODS: 2 19 ZONING: C-2 A. THE PARAPET WALL OF THE BUILDING SHALL EQUAL OR EXCEED THE HEIGHT | | 8 4 OF THE MECHANICAL UNITS, OR; | = 34 LOT 1 B. BY LOCATING THE MECHANICAL EQUIPMENT BEHIND THE ROOF PLANES IN | 5 — THE CASE OF MANSARD, HIP OR OTHER THAN FLAT ROOF. | 42 io HATCHED AREA REVIEWED AS SEPARATE APPLICATION DR25-03 Alrreports plans, epestications, note 7. ROOF MOUNTED MECHANICAL EQUIPMENT ENCLOSURES OR EQUIPMENT | : reports, plans, specifications, notes SCREEN WALLS SHALL NOT PROJECT ABOVE THE ROOF PARAPET. TO THE | 27 12 and information prepared by PHNX EXTENT PERMITTED BY LAW, SATELLITE DISHES SHALL BE FULLY SCREENED LOT 2 DESIGN and their consultants shall BY A PARAPET WALL. | 14 remain the property thereto. PHNX 8. GROUND MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED NET SITE AREA: 29,024 S.F. (0.67 AC) wane shall ain all corm a FROM VIEW (FROM STREETS OR SURROUNDING COMMERCIAL USES) BY A . s statutory and other reserved rights, COMBINATION OF DECORATIVE WALLS AND AN EVERGREEN VEGETATIVE | 2 NUILDING AREAL AREA: oO Se (22.2%) including the copyright thereto. HEDGE EQUAL TO OR EXCEEDING THE HEIGHT OF THE EQUIPMENT. | 3 45-0" KEM: F. 9. PNEUMATIC TUBES, WHETHER METAL OR PLASTIC, SHALL BE EITHER: 7 | PATIO AREA: _ 700 SF. A. ENCLOSED IN PILASTERS, COLUMNS OR OTHER ARCHITECTURAL FEATURES ses ’ TOTAL AREA: 1,500 SF. B. ROUTED UNDERGROUND. on | ee SS | CONSTRUCTION TYPE: V-B SPRINKLERED 10. ALL BACKFLOW PREVENTION DEVICES 2” OR LARGER SHALL BE SCREENED | | LOT COVERAGE: 1,500 / 29,024 X 100 = 5.35% WITH LANDSCAPE LOCATED WITHIN A 6’ RADIUS OF THE DEVICE. ALL | 13 | (2)—+ BACKFLOW PREVENTERS LESS THAN 2” SHALL BE PLACED IN A WIRE CAGE | | 28 7 eT aT PAINTED TAN DESERT LANDSCAPE, GREEN IN TURF AREAS. : 11. ALL FREESTANDING LIGHT POLES SHALL: 4 | SERVING AREAS: (1/75) 11 SPACES A. BE LOCATED WITHIN LANDSCAPED AREAS OR PLANTER ISLANDS. | | PATIO (1/400) 2 SPACES B. HAVE CONCRETE BASES PAINTED TO MATCH THE PRIMARY BUILDING COLOR 9 09 | TOTAL 13 SPACES OR FINISHED TO MATCH PARKING SCREEN WALLS. CONCRETE BASES FOR _| | | LIGHT POLES SHALL NOT EXCEED A HEIGHT OF 30” FROM ADJACENT GRADE. 10 TOTAL PARKING PROVIDED: 17 SPACES (2 ADA) C. BELOCATED TO AVOID CONFLICT WITH TREES. woe | | 23-0" | 12. LANDSCAPED AREAS ADJACENT TO PUBLIC RIGHT-OF-WAY SHALL BE | 8 26 NOTE: MOUNDED AND NATURALLY CONTOURED. NO MORE THAN 50% OF THE io 27 | - 1B CROSS ACCESS AGREEMENT AND SHARED TRASH IN PERPETUITY. REQUIRED (RIGHT-OF-WAY AND LANDSCAPING TRACTS) LANDSCAPING —I BO © |8 FRONTING ADJACENT STREETS MAY BE USED FOR RETENTION. RETENTION Z => 8 od 6 |S Z AREA SIDE SLOPES SHALL BE VARIED, AND NO SLOPE SHALL EXCEED A 4:1 98 oN 8 14 3 4 od . MAXIMUM. Se | 5 14 | _ a @) KEYNOTES: 13. COMMERCIAL BUILDING DOWNSPOUTS SHALL BE INTERNALIZED. os | ae | oF 14. COMMERCIAL DEVELOPMENT VEHICULAR, ACCESS POINTS AND PEDESTRIAN 3 2 | 2, | a | |= oS 1. ADJACENT PROPERTY IS EXISTING AND WILL REMAIN AS IS. TO x 37 22 27 | = as) 2. PROPOSED ASPHALT DRIVE AREA, REFER TO CIVIL DRAWINGS. NR ATNe eer STAMPED CONCRETE, BOAMANITE, OR SIMILAR & wi N | ~ & wi 3. PROPOSED LANDSCAPE AREA, REFER TO LANDSCAPE DRAWINGS. . LOCATION AND MATERIAL SHALL BE REVIEWED AND Ww 8 (2) 24 fo) WB 4. 4" WIDE YELLOW PAINT STRIPING, REFER TO DETAIL 20/A101. APPROVED BY THE PLANNING DEPARTMENT PRIOR TO THE ISSUANCE OF A Sa S 15 7 4 | ° Sa 5. REFUSE ENCLOSURE, SIZE TO MATCH CITY OF GLENDALE STANDARD DETAIL BUILDING PERMIT. 36 16 LL | n 36 G-934, REFER TO DETAIL 14/A101. 15. CUSTOMER, EMPLOYEE AND VISITOR PARKING SHALL BE SCREENED FROM 26 27 “on i | | 26 6. CONCRETE HARDSCAPE AREA. STREET VIEW BY LOW MASONRY WALLS. THE PARKING SCREEN WALLS SHALL We 6 17 wo ; i? WZ 7. ELECTRICAL SERVICE ENTRANCE SECTION (SES) LOCATION. BE FINISHED ON BOTH SIDES USING THE SAME MATERIALS AND COLORS, AND rar | 9 12 o (=) Ee = | rar 8. ASPHALT DRIVE THRU LANE, REFER TO CIVIL DRAWINGS. A DESIGN TO COMPLEMENT THAT OF THE MAIN BUILDING. an 25 3 8S ar | aN 9. BYPASS LANE. YELLOW 4" WIDE PAINT STRIPING, REFER TO DETAIL 20/A101. 16. ALL EXTERIOR METAL SHALL BE FINISHED OR PAINTED TO MATCH THE | [io | 10. RAISED SIDEWALK FOR STAFF TO TAKE ORDERS ONLY, REFER TO DETAIL APPROVED PROJECT COLORS. 46/101. 17. EXISTING ON-SITE PLANT MATERIAL DAMAGED DURING CONSTRUCTION —_ 23 LOT 2 | 11. BIKE RACK, REFER TO DETAIL 4/A101. SHALL BE REPLACED WITH COMPARABLE SPECIES AND SIZE. 4 ee) MAE ee 46-10" 12. CONCRETE ACCESSIBLE CURB RAMP, REFER TO DETAIL 5 & 6/A101, 15 "47 | 13. YELLOW 4" WIDE PAINT STRIPING IN DRIVE-THRU LANES, REFER TO DETAIL - 14. MENU DISPLAY BOARDS (NO ORDER SPEAKER AT THESE LOCATIONS), REFER — 2 TO ELECTRICAL DRAWINGS. REFER TO DETAIL1/A104 FOR MENU BOARD 4 35 3 DESIGN, AND STRUCTURAL CALCULATIONS ATTACHED. 4 15. DASHED LINE INDICATES BUILDING CANOPY, TO BE SPRINKLERED. 15 16. KNOCK BOX LOCATION. 28 17. ACCESSIBLE PARKING SPACES, REFER TO DETAIL 1/A101. V | C | N TY M AP 10'-4" gf 11'-0" 18. EXISTING SIDEWALK TO REMAIN, TYP. SCALE: NOT TO SCALE 07 19. YELLOW PAINTED DIRECTIONAL ARROWS, TYPICAL, REFER TO DETAIL 17/A101. | 15 3 27 20. 12'-0" WIDE BY 20'-0" LONG CONCRETE PAD CENTERED AT DRIVE-THROUGH WINDOW REFER TO DETAIL 8/A101. | 9 20 11 21. NEW ADA PARKING SIGN 6 19 22. 4" THICK CONCRETE ACCESS SIDEWALK, REFER TO CONCRETE JOINT DETAILS W OLIVE AVE TIM101. 8 n 23. DASHED LINE DENOTES ACCESSIBLE ROUTE FROM SIDEWALK. 12 8 24. FDC LOCATION. PROJ ECT 27 3 —— 25. FIRE RISER ROOM LOCATION. Y) Lu | 26. ELECTRICAL TRANSFORMER, PAINT TO MATCH ADJACENT BUILDING. 5 | 27. PROPOSED 6" CONCRETE CURB, TYP. > | Qe (40) | 28. PROPERTY LINE, REFER TO CIVIL DRAWINGS <x 29 agl\s —-@) - 29. 4'-0" HIGH C.M.U. SCREEN WALL AS INDICATED. REFER TO DETAIL 18/A101. 29 Bg|e | | [— 30. EXISTING 5'-4" CMU WALL TO REMAIN. Zz 3 Qs TYP. i | 31. EXISTING ASPHALT DRIVE AREA TO REMAIN. W NORTHERN AVE 22 — i —u + — 32. EXISTING CONCRETE CURB TO REMAIN. ww —_ — — a ; HL | 33. EXISTING LANDSCAPE AREA TO REMAIN. L \@) vom 104'-7 1/2" 4 WA 34. PROPOSED HEIGHT RESTRICTION BAR LOCATION. LU . w © w w (28) 113-2 \ (45) 35. PIPE BOLLARD, REFER TO DETAIL 18/A101. LN > Py 2 > | (23) ~ . MENU BOARDS WITH SPEAKER. < Ne = < . MILK CRATE ENCLOSURE, REFER TO DETAIL 1/A102 - <x = IL, = i) . DECEL LANE, REFER TO CIVIL DRAWINGS FOR ADDITIONAL INFORMATION. ad tS ¢ 8 B . POWER POLE LOCATION. - Zz z Zz . DASHED LINE INDICATES COLLECTION ROUTE, MIN. 16'-0" WIDE WITH A 44" C) O LU OUTSIDE RADIUS AND 28'-6" INSIDE RADIUS. W GLENDALE AVE _ 30" x 30" YIELD SIGN LOCATION. z = . SLOPED CURB, TYP., REFER TO DETAIL 16/A101. <x ‘9 ._ WATER METER LOCATION, REFER TO CIVIL DRAWINGS. = OQ rs . WATER VAULT LOCATION, REFER TO CIVIL DRAWINGS. Qi . SIGHT VISIBILITY TRIANGLE PER DETAIL G-448. z o - PROPOSED MONUMENT SIGN. (>) LU a . PARKING STOPS. S J = Os o O ie N iad a REVISION N N oO = wT Received + N iad 05/15/2025 D oO PROPOSED & SITE PLAN 2 0 10! 40' 5 Zz ee 5 ” NORTH s A100 | to 1 | PROPOSED SITE PLAN SCALE: 1" = 20'-0" o) PHNX DESIGN #: 24-490 Q