Extracted text (via pymupdf)
3215 characters
W W W W W W W W 24'-0" GOODWILL 22539 SF 218'-4" 133'-4" 97'-4" 182'-8" 36'-0" 35'-8" 7 7 7 10 9 15 16 16 16 8 60'-1 1/4" 67'-3 3/4" 20'-0" TYP. 11'-0" 5'-0" 11'-0" 10'-0" TYP. 1 1 2 TYP. 2 TYP. 2 TYP. 3 3 3 3 4 4 4 5 6 6 6 7 8 9 10 10 11 12 12 13 13 14 15 15 15 16 TYP. 17 18 19 20 21 21 20 20 TYP. 20 22 23 A R C H I T E C S T , I N C SEC 75TH AVE AND GLENDALE AVE GLENDALE, AZ GOODWILL DATE: 07-06-2022 (PRELIMINARY) NORTH SCALE: SITE PLAN - GOODWILL 1" = 20'-0" RKAA# 21202.03 SP-1 2 0 1 6 R K A A ARCHITECTS, INC. ALL RIGHTS RESERVED. THIS DRAWING IS AN I N S T R U M E N T O F SERVICE. IT IS THE PROPERTY OF RKAA ARCHITECTS, INC. AND M A Y N O T B E DUPLICATED, USED OR DISCLOSED WITHOUT WRITTEN PERMISSION OF THE ARCHITECT. © 20' 40' 10' 0' SITE DATA THE NORTH 663 FEET (RECORDED) 663.37 FEET (MEASURED) OF THE WEST 663 FEET (RECORDED) 663.37 FEET (MEASURED) OF THE NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF SECTION 12, TOWNSHIP 2 NORTH, RANGE 1 EAST OF THE GILA AND SALT RIVER BASE AND MERIDIAN, MARICOPA COUNTY, ARIZONA; EXCEPT THE NORTH 225 FEET (RECORDED) 225.14 FEET (MEASURED) OF THE WEST 253 FEET (RECORDED) 253.14 FEET (MEASURED); AND EXCEPT THE NORTH 55 FEET (RECORDED) 55.03 FEET (MEASURED); AND EXCEPT THE WEST 55 FEET (RECORDED) 55.03 FEET (MEASURED) THEREOF. 1. PROVIDE DIRECTIONS ARROWS, STRIPING, PAINTED CURBS, ETC AS NECESSARY. STRIPING TO BE 4" WHITE. ALL SITE SURFACE STRIPING AND PAINTING TO BE KEPT TO A MINIMUM 2. B.S. / BS = BUILDING SETBACK 3. LS = LANDSCAPE 4. SIGN REGULATIONS, PARKING REGULATIONS, AND ADDITIONAL REQUIREMENTS SHALL CONFORM TO THE TOWN OF GLENDALE DEVELOPMENT CODE 5. ALL COMMERCIAL AND INDUSTRIAL SITE PLANS SHALL COMPLY WITH THE COMMERCIAL AND INDUSTRIAL DESIGN STANDARDS AND GUIDELINES 6. SIGNAGE UNDER A SEPARATE PERMIT LEGAL DESCRIPTION GENERAL NOTES KEY NOTES 144-01-004C C-2 0.98 ACRES (42,472 S.F.) GRAY SHELL RETAIL PAD 22,539 S.F. 90 SPACES 9 SPACES 99 SPACES 111 SPACES 05 SPACES 05 SPACES 04 SPACES 04 SPACES XX S.F. (XX%) PARCEL NUMBER (APN): EXISTING ZONING: GROSS SITE AREA: PROPOSED USE: BUILDING AREA: TOTAL BUILDING AREA PARKING REQUIRED: RETAIL - 1/250 S.F. 10% ADDL FOR MORE INTENSE USE TOTAL PARKING REQUIRED PARKING PROVIDED: ACCESSIBLE SPACES REQUIRED: ACCESSIBLE SPACES PROVIDED: BICYCLE PARKING REQUIRED: BICYCLE PARKING PROVIDED: ONSITE LANDSCAPE AREA PROVIDED: 1. FIRE TRUCK TURNING PATH 2. CURB - REFER TO CIVIL DRAWINGS 3. ASPHALTIC CONCRETE PAVING - REFER TO CIVIL 4. CONCRETE SIDEWALK - REFER TO CIVIL 5. KNOX BOX - 3200 SERIES. NOTE: KEY (KNOX) BOX SHALL BE LOCATED 6' ABOVE GRADE AND WITHIN 5' OF DOOR TO FIRE RISER AREA 6. ADA RAMP - SLOPE NOT TO EXCEED 1:12 7. PEDESTRIAN PATH OF TRAVEL TO PUBLIC RIGHT OF WAY 8. FIRE DEPARTMENT CONNECTION (F.D.C.) - INSTALL PER MUNICIPAL GUIDELINES 9. BICYCLE PARKING - SEE DETAIL 10. FIRE HYDRANT 11. TRASH ENCLOSURE PER COG DETAIL G-934. 12. PROPERTY LINE 13. EXISTING MASONRY SCREEN WALL 14. RETAINING WALL - REFER TO CIVIL 15. ACCESSIBLE PARKING STALL 16. WHEEL STOP 17. MASONRY SCREEN WALL 18. TRASH COMPACTOR 19. CONCRETE DELIVERY TRUCK WELL 20. LANDSCAPING 21. DIRECTIONAL STRIPING 22. FIRE RISER Drop off area : 4’ - 0” sub-grade - 8’ - 0” Received [7 NOV 2022] PLANNING DIVISION