AGREEMENT STEWART MTN DAM W_EXHIBITS 04.23.2020.PDF

Maricopa County — Formal (2020-05-20)

View PDF Item 50 Meeting page

Extracted text (via pymupdf) 46486 characters
1 
Site-Specific Supplemental Agreement to IGA G-  
2020 SSSA for Stewart Mountain Hydro Dam Site v8 final 
SITE-SPECIFIC SUPPLEMENTAL AGREEMENT 
TO 
INTERGOVERNMENTAL AGREEMENT 
BETWEEN 
MARICOPA COUNTY 
AND 
SALT RIVER PROJECT  
AGRICULTURAL IMPROVEMENT AND POWER DISTRICT 
 
MARICOPA COUNTY Agreement Number G-30222 
 
C-78-20-_____-__-__ 
 
This Site Specific Supplemental Agreement (“SSSA”) is entered into as of the last 
day executed below by and between the Salt River Project Agricultural Improvement and 
Power District, (“SRP”), a political subdivision of the State of Arizona and Maricopa 
County (“COUNTY”), a political subdivision of the State of Arizona (“SRP” and 
“COUNTY” shall collectively be referred to herein as the “Parties” or individually as a 
“Party”).  This SSSA is entered into pursuant to terms of that certain Intergovernmental 
Agreement G-30156 entered into by the Parties dated effective July 8, 2013, as amended 
by that certain Amendment No. 1 to Intergovernmental Agreement G-30156 (hereinafter 
the Intergovernmental Agreement G-30156 and the Amendment No. 1 to the 
Intergovernmental Agreement G-30156 are collectively referred to as the “IGA” and the 
IGA and the SSSA are sometimes hereinafter collectively referred to as the “Agreement”). 
 
 
This Agreement is also subject to, and governed by, that certain Salt River Project 
Land Use License (also known as Maricopa County License No. P-50349) dated effective 
________________, 2020 (the “License”).  In the event of any conflict between this 
Agreement and the License, the License shall control.  
 
RECITALS 
 
 
WHEREAS, the purpose of the IGA is to fulfill the need for establishing modern 
and reliable radio communication systems and related equipment ("Communication 
Systems") for SRP and COUNTY and to allow for co-locating and/or co-using the 
Communication Systems of the other Party, including sites, facilities, equipment, systems, 
and/or appurtenances. The use of SRP controlled sites, facilities, equipment, systems 
and/or appurtenances (“SRP Sites”) for the purpose of providing County with much needed 
radio coverage and the use of COUNTY controlled sites, facilities, equipment, systems 
and/or appurtenances (“County Sites”) (“SRP Sites” and “County Sites” shall collectively 
be referred to herein as the “Site” or “Sites”) for the purpose of providing SRP much needed 
radio coverage not presently available and will enhance Communications Systems of the 
Parties.  
 
 
WHEREAS, it is understood by the Parties hereto that SRP and the Salt River 
Valley Water Users’ Association (Association) manage the property legally described as

2 
Site-Specific Supplemental Agreement to IGA G-  
2020 SSSA for Stewart Mountain Hydro Dam Site v8 final 
the Northeast quarter of Section 33, Township 3 North, Range 8 East of the Gila and Salt 
River Meridian (GSRM), Maricopa County, Arizona with a street address of 12851 N. Bush 
Hwy Mesa, Arizona, 85215, commonly known as the Stewart Mountain Dam Hydro 
Generating Station (the “Facility”) pursuant to contracts with the United States of America 
(“USA”), which assign to SRP the responsibility and authority for the care, operation, 
maintenance and management of the Salt River Reclamation Project (“Reclamation 
Project”) of which the Facility is a part. The Facility location is depicted on EXHIBIT 
“A” (Facility Location – Stewart Mountain Dam) attached hereto and made a part hereof.  
 
 
WHEREAS, COUNTY requires a reliable wireless communication system for the 
purpose of meeting its public safety and government agency responsibilities.  
 
 
WHEREAS, COUNTY desires to co-locate at or co-use the Facility for the purpose 
of backhaul of the County’s radio bandwidth via the SRP fiber optic network.  
 
 
WHEREAS, the Parties desire to enter into this SSSA to permit COUNTY to co-
locate in order to support its public safety initiative. 
 
TERMS OF AGREEMENT 
 
NOW THEREFORE, in consideration of the mutual promises and undertakings of 
the Parties hereinafter set forth herein and other good and valuable consideration, the 
sufficiency and adequacy of which the Parties acknowledge, it is hereby agreed as follows: 
 
1. 
RECITALS.  The Recitals, by this reference, shall be incorporated herein and are 
made a part of this SSSA. 
 
2. 
SRP RESPONSIBILITIES: 
 
a. SRP shall provide the COUNTY adequate access to the Facility only during 
SRP work hours for maintenance.  Facility specific contacts, hours and access 
procedures are set forth in EXHIBIT “E”, attached hereto and made a part 
hereof. 
 
b. SRP shall provide Facility safety training for the SRP pre-approved designated 
COUNTY staff and its approved agents that access the Facility. 
 
c. SRP shall provide a connection to SRP’s fiber optic network inside SRP’s 
communications building located at the Facility as more particularly described 
and depicted in EXHIBIT “B”, attached hereto and made a part hereof. 
 
d. SRP will provide area for the COUNTY to add their own communications 
cabinet, as more particularly described and depicted on EXHIBIT “B”. 
 
e. SRP will provide area on the second stanchion of the Gantry Crane near SRP’s 
communications building necessary for the COUNTY to mount their

3 
Site-Specific Supplemental Agreement to IGA G-  
2020 SSSA for Stewart Mountain Hydro Dam Site v8 final 
microwave radio dish, as more particularly described and depicted on 
EXHIBIT “B” and detailed on Sheet A-3. 
 
f. SRP shall pull and terminate one (1) 12 strand fiber optic cable from the 
COUNTY’s outdoor equipment cabinet to SRP’s existing communication 
building, as more particularly described and depicted on EXHIBIT “D”, 
attached hereto and made a part hereof. 
 
g. The Parties hereby agree this SSSA does not give the COUNTY the authority 
to enter into any other agreement with a third party to utilize the aforementioned 
SRP-owned fiber optic service for any other purposes beyond the planned 
public safety initiative, without the written approval of SRP, which approval 
may be withheld or granted in SRP’s sole and absolute discretion.   
 
h. NOTICE IS HEREBY PROVIDED and the Parties hereby agree that approval 
of this SSSA by the Parties does not constitute approval of either Party of any 
permits or approvals that may be necessary for construction of the site 
improvements as herein described.  SRP and COUNTY shall work 
cooperatively to obtain any and all necessary permits from the requisite federal, 
state or local jurisdiction(s).  The COUNTY shall pay for all required 
construction permits.  
 
3. 
COUNTY RESPONSIBILITIES: 
 
a. Upon receipt of invoice, COUNTY shall pay SRP, in advance, an amount not 
to exceed Eighty Thousand Four Hundred Thirty-Two and NO/100 Dollars 
($80,432.00), for the complete scope of work at the COUNTY’s Stewart 
Mountain Communication Site as more fully detailed in EXHIBIT “C”, 
attached hereto and made a part hereof.  
 
b. COUNTY shall provide SRP with the necessary access (i.e. key, proximity 
card, combination code, etc.) to the COUNTY outdoor equipment cabinet 
located at the Facility in order to operate and maintain the fiber, fiber panel and 
the fiber route.  
 
c. COUNTY has provided SRP with the necessary points of contact and call-in 
procedures needed in order to access the COUNTY outdoor equipment 
cabinet at the Facility within EXHIBIT “E”, attached hereto and made a part 
hereof.  
 
d. COUNTY shall be responsible for their own future enhancements and upgrades 
as well as the costs associated for labor and materials to perform such future 
enhancements and upgrades. 
 
e. COUNTY shall provide trenching for fiber optic installation and civil 
construction as well as conduit and pull rope for SRP’s use.

4 
Site-Specific Supplemental Agreement to IGA G-  
2020 SSSA for Stewart Mountain Hydro Dam Site v8 final 
 
f. County shall provide routine maintenance (including maintaining the 
appearance) of the County equipment, including, but not limited to, the 
generator located at the Facility.  
 
g. COUNTY shall restore all removed ground during excavation for underground 
conduit to SRP’s ground and pavement specifications, which are set forth in the 
attached EXHIBIT “F”.  
 
h. COUNTY will mount its microwave radio dish on SRP’s gantry crane 
stanchion in a manner than ensures the gantry crane’s path remains clear and 
unobstructed and will not damage the integrity of the stanchion.  
 
i. COUNTY will access the Facility during the SRP work hours and with prior 
SRP approval, as specified in Exhibit “E”. .  Facility specific contacts, hours 
and access procedures are set forth in EXHIBIT “E”. 
 
j. COUNTY shall provide their own fiber jumpers from the provided fiber panel 
to their own equipment.  Installed fiber jumpers shall be SC-APC connectors.   
 
k. COUNTY shall be responsible for the design and construction for the 
installation of the County equipment. COUNTY agrees to provide the funding 
for all equipment, design and construction costs incurred by SRP.  COUNTY 
agrees to provide the funding and expertise to produce the documents (studies, 
engineering drawings and specifications) required for COUNTY to obtain any 
required permit(s) as needed.   
 
4. 
CANCELLATION/TERMINATION:  The Parties agree that the term, cancellation 
and termination of this SSSA will be governed by IGA G-30156.  
 
5. 
ENTIRE AGREEMENT.  This SSSA, together with any exhibits attached hereto 
and any agreements executed contemporaneously herewith, including but not 
limited to the IGA and License referenced herein, constitutes the entire agreement 
between the Parties and sets forth all of the covenants, promises, agreements, 
conditions and understandings between COUNTY and SRP, and there are no 
covenants, promises, agreements, conditions or understandings, either oral or 
written, between COUNTY and SRP other than as set forth herein and referenced 
above.  This SSSA shall be construed as a whole and in accordance with its fair 
meaning and without regard to any presumption or other rule requiring construction 
against the party drafting this SSSA.  This SSSA cannot be modified or changed 
except by a written instrument executed by COUNTY and SRP.   
 
 
(Signatures follow on next page)

5 
Site-Specific Supplemental Agreement to IGA G-  
2020 SSSA for Stewart Mountain Hydro Dam Site v8 final 
Signature Page to Site-Specific Supplemental Agreement - G- 30222 
2020 SSSA for Stewart Mountain Communication Site  
 
 
 
 
MARICOPA COUNTY, a political 
subdivision of the state of Arizona  
 
SALT RIVER PROJECT 
AGRICULTURAL IMPROVEMENT 
AND POWER DISTRICT, a political 
subdivision of the state of Arizona 
  
AUTHORIZED SIGNATURE: 
 
AUTHORIZED SIGNATURE: 
 
 
_______________________________ 
Clint Hickman 
 
 
_______________________________ 
Kyle Cormier 
Chairman of the Board of Supervisors 
 
 
Director - Telecommunication Systems 
 
DATE:_________________________ 
 
DATE:________________________ 
 
 
 
ATTEST:  
 
 
_______________________________ 
Clerk of the Board of Supervisors  
 
 
Date: __________________________

6 
Site-Specific Supplemental Agreement to IGA G-  
2020 SSSA for Stewart Mountain Hydro Dam Site v8 final 
The foregoing Agreement has been submitted to legal counsel for the County for review 
and approval. The undersigned attorney has determined that said agreement is in proper 
form and is within the powers and authority granted under the laws of the State of Arizona.  
 
Dated this ___________ day of ___________________, 2020  
By______________________________________________ 
 
Deputy County Attorney 
 
 
 
 
 
I hereby state that I have reviewed the proposed Agreement, between Maricopa County 
and Salt River Project Agricultural Improvement and Power District, pursuant to A.R.S. § 
11-952, and declare the Agreement to be in proper form and within the powers and 
authority granted to Salt River Project Agricultural Improvement and Power District under 
the laws of the State of Arizona. 
 
 
 
By: ____________________________________ 
 
_________________ 
Leo L. Miller   
 
 
 
 
 
Date 
SRP Senior Attorney

7 
Site-Specific Supplemental Agreement to IGA G-  
2020 SSSA for Stewart Mountain Hydro Dam Site v8 final 
 
 
SCHEDULE OF EXHIBITS 
 
 
EXHIBIT “A” - Facility Location – Stewart Mountain Dam (3 pages, including marked 
aerial and Site Plans (Option 2) 
 
EXHIBIT “B” - Approved Maricopa County/Motorola Solutions P25 Radio System 
Infrastructure Upgrade Plans (OPTION 2) – Site Name: Stewart Dam (rev 2. dated 
05.09.18) containing the following sheets: 
 
Sheet Index 
Title 
Description  
A-1 
OVERALL SITE PLAN  (OPTION 2)  
A-2 
ENLARGED SITE PLAN (OPTION 2) 
A-3 
ELEVATION (OPTION 2) 
E-3 
ONE-LINE DIAGRAM (OPTION 2) 
G-1 
GROUNDING PLAN (OPTION 2) 
 
(5 pages) 
 
EXHIBIT “C” – Stewart Mountain Dam Communications Estimate 4-5-2018 including 
Construction Inspector Estimate dated 12/03/2018 (total of 2 pages)  
 
EXHIBIT “D” – Site Connection Diagram 
 
EXHIBIT “E” – List of Contacts and Call-In Procedures for Facility Access (including 
Cabinets and Fence)  
 
EXHIBIT “F” –SRP’s Ground and Pavement Specifications [Part (1) STANDARD 
SPECIFICATION FOR UTILITY TRENCH EXCAVATION AND BACKFILLING – 
10 pages) and Part (2) Detail 200-1 (1 page)]

EXHIBIT “A” 
“Facility Site Plan” – Stewart Mountain Dam 
 
(Attached – 3 pages)

Maricopa County GIO, Maricopa County Assessor's Office
O
10/7/2016  12:54:25 PM
Exhibit "A"
Facility Location - Stewart Mountain Dam
Exhibit "A"     Page 1 of 3
Gantry Crane stanchion to 
be used for MW Mount.  
Proposed 2' Microwave 
Antenna to be mounted at 
top (23' - 6" A.G.L) of 
stanchion, clear of gantry 
cranes path
Underground conduit (2) 
6", from stanchion 
location to (N) Maricopa 
County Cabinets.  
Asphalt paving to be 
removed and replaced 
(approx. 200 sq. ft) to 
accommodate new 
Maricopa County 
underground conduit 
from stanchion to new 
cabinet location
New Maricopa County 
project area to include a 
new 35 kW backup 
generator, new 2-Bay 
outdoor equipment 
cabinet with electrical 
service and H-Frame, 
and (6) 50g LP tanks 
within a walled enclosure 
(around LP tanks only)
New Maricopa County 
underground electrical 
service from existing 
SRP power pole to new 
County H-Frame 
location
New underground 
conduit from Maricopa 
County cabinets to the 
existing SRP 
communications shelter
**The areas in red hatch below 
show the approximate locations 
of the County equipment**

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
E
E
E
E
E
E
E
M
M
M
M
M
M
GAS
GAS
GAS
GAS
E
E
E
E
E
E
E
E
E
E
M
M
M
M
M
TEL
TEL
Copyright ©ADW Communications Services, INC (ADWCOMM). This document is a proprietary item of ADWCOMM and contains information solely for use on a specific project. It cannot be used, disclosed or reproduced in any format without ADWCOMM 's prior written permission
COMMUNICATIONS SERVICES, INC.
A R I Z O N A
1
8
7
1
M
A
R
I
C
O
P
A
C
O
U
N
T
Y
#
1
4
6
7
5
3
2
Call Toll Free
1-800-782-5348
2 Working Days Before You Dig
ARIZONA BLUE STAKE, INC.
EXHIBIT "A"    Page 2 of 3

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O/H
O/H
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
M
M
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
Call Toll Free
1-800-782-5348
2 Working Days Before You Dig
ARIZONA BLUE STAKE, INC.
Copyright ©ADW Communications Services, INC (ADWCOMM). This document is a proprietary item of ADWCOMM and contains information solely for use on a specific project. It cannot be used, disclosed or reproduced in any format without ADWCOMM 's prior written permission
COMMUNICATIONS SERVICES, INC.
A R I Z O N A
1
8
7
1
M
A
R
I
C
O
P
A
C
O
U
N
T
Y
#
16
4
1
5
9
6
17
12
3
2
8
15
7
11
10
14
13
18
19
20
18
EXHIBIT "A"    Page 3 of 3

EXHIBIT “B”  
Approved Maricopa County/Motorola Solutions P25 Radio System Infrastructure 
Upgrade Plans (OPTION 2) – Site Name: Stewart Dam (rev 2. dated 05.09.18) 
containing the following sheets: 
 
Sheet Index 
Title 
Description  
A-1 
OVERALL SITE PLAN  (OPTION 2)  
A-2 
ENLARGED SITE PLAN (OPTION 2) 
A-3 
ELEVATION (OPTION 2) 
E-3 
ONE-LINE DIAGRAM (OPTION 2) 
G-1 
GROUNDING PLAN (OPTION 2) 
 
(5 pages)

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
E
E
E
E
E
E
E
M
M
M
M
M
M
GAS
GAS
GAS
GAS
E
E
E
E
E
E
E
E
E
E
M
M
M
M
M
TEL
TEL
Copyright ©ADW Communications Services, INC (ADWCOMM). This document is a proprietary item of ADWCOMM and contains information solely for use on a specific project. It cannot be used, disclosed or reproduced in any format without ADWCOMM 's prior written permission
COMMUNICATIONS SERVICES, INC.
A R I Z O N A
1
8
7
1
M
A
R
I
C
O
P
A
C
O
U
N
T
Y
#
1
4
6
7
5
3
2
Call Toll Free
1-800-782-5348
2 Working Days Before You Dig
ARIZONA BLUE STAKE, INC.
EXHIBIT "A"    Page 2 of 3
EXHIBIT B PAGE 1 of 5

X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
O/H
O/H
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
M
M
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
TEL
Call Toll Free
1-800-782-5348
2 Working Days Before You Dig
ARIZONA BLUE STAKE, INC.
Copyright ©ADW Communications Services, INC (ADWCOMM). This document is a proprietary item of ADWCOMM and contains information solely for use on a specific project. It cannot be used, disclosed or reproduced in any format without ADWCOMM 's prior written permission
COMMUNICATIONS SERVICES, INC.
A R I Z O N A
1
8
7
1
M
A
R
I
C
O
P
A
C
O
U
N
T
Y
#
16
4
1
5
9
6
17
12
3
2
8
15
7
11
10
14
13
18
19
20
18
EXHIBIT "A"    Page 3 of 3
EXHIBIT B PAGE 2 of 5

EXHIBIT B PAGE 3 of 5

EXHIBIT B PAGE 4 of 5

EXHIBIT B PAGE 5 of 5

EXHIBIT “C” 
Stewart Mountain Dam Communications Estimate 4-16-2018, 
including Construction Inspector Estimate dated 12/03/2018 (total of 2 pages)  
 
(Attached 2 pages)

REGULAR
CONT SVCS
CONT SVCS
BUDGETED
TOTAL
DEPARTMENT
LABOR
LOADED
NON-LOADED
MATERIALS
OTHER
OVERHEADS
LOADED
8191010
5050050
5050250
8185000
8198000
ADMIN / SCOPE DEVELOPMENT
$2,080
$0
$0
$0
$4,936
$7,016
TS  Engineering
0
0
0
0
0
0
TS  Infrastructure
0
0
0
0
0
0
TS  C&M
0
0
0
0
0
0
TS  Operations
0
0
0
0
0
0
TS  Performance
2,080
0
0
0
4,936
7,016
DESIGN
2,532
0
0
0
6,008
8,540
TS  Engineering
2,352
0
0
0
5,581
7,933
TS  Infrastructure
180
0
0
0
427
607
CONSTRUCTION
2,200
0
0
6,071
0
5,713
13,984
Materials
6,071
493
6,564
TS  Engineering
0
0
0
0
0
0
TS  Infrastructure
0
0
0
0
0
0
TS  C&M
2,200
0
0
0
5,221
7,421
Non-Telecommunication Systems W
0
0
0
0
0
0
0
MCM - Fabrication
0
0
0
0
0
0
0
Other 1
0
0
0
0
0
0
0
Other 2
0
0
0
0
0
0
0
Other 3
0
0
0
0
0
0
0
Other 4
0
0
0
0
0
0
0
Other 5
0
0
0
0
0
0
0
INSTALLATION RECORD
180
0
0
0
0
427
607
Grand Total
$6,992
$0
$0
$6,071
$0
$17,085
$30,148
DEFINITIVE ESTIMATE SUMMARY
Project: Stewart Mtn Dam County Estimate  - County Backhaul
#VALUE!
ESTIMATE DATE: 02/27/2018
Stewart Mtn Dam Communications Estimate 4-16-2018 (002).xlsx
7/8/2019
04/16/2018
NOTE: Separate Stewart Mountain Dam Construction Inspector Exhibit dated 
12/03/2018 with print date 02/12/2019 in footer follows on Next Page

ESTIMATOR: Arturo Moreno
ESTIMATE DATE: 12/03/2018
 
 
BASE
REGULAR
BASE
CONT SVCS
CONT SVCS
BUDGETED
TOTAL
TOTAL
TOTAL
Task
DEPARTMENT
Work Group
HOURS
RATE
LABOR
HOURS
RATE
LOADED
NON-LOADED
DIRECT BUY
WAREHOUSE
MATERIALS
OTHER
PRIMARY
OVERHEADS
LOADED
8191010
5050050
5050250
5053550
5053001
8185000
8198000
COSTS*
COSTS*
ADMIN / SCOPE DEVELOPMENT
0
$0
0
$0
$0
$0
$0
$0
$0
$0
TS  Engineering
0
0
0
0
0
0
0
0
0
0
500
Project Management
ComEng
0
55.00
0
0
65.00
0
0
0
0
0
0
0
502
Administration
ComEng
0
55.00
0
0
65.00
0
0
0
0
0
0
0
510
RFP/Q Management
ComEng
0
55.00
0
0
65.00
0
0
0
0
0
0
0
TS  Infrastructure
0
0
0
0
0
0
0
0
0
0
500
Project Management
ComFiber
0
45.00
0
0
46.00
0
0
0
0
0
0
0
502
Administration
ComFiber
0
45.00
0
0
46.00
0
0
0
0
0
0
0
508
Preliminary Inf Estimate
ComWrls
0
45.00
0
0
46.00
0
0
0
0
0
0
0
509
Preliminary Fiber Design
ComFiber
0
45.00
0
0
46.00
0
0
0
0
0
0
0
510
RFP/Q Management
ComFiber
0
45.00
0
0
46.00
0
0
0
0
0
0
0
500
Project Management
ComWrls
0
45.00
0
0
46.00
0
0
0
0
0
0
0
502
Administration
ComWrls
0
45.00
0
0
46.00
0
0
0
0
0
0
0
510
RFP/Q Management
ComWrls
0
45.00
0
0
46.00
0
0
0
0
0
0
0
TS  C&M
0
0
0
0
0
0
0
0
0
0
500
Project Management
ComCM
0
55.00
0
0
46.00
0
0
0
0
0
0
0
502
Administration
ComCM
0
55.00
0
0
46.00
0
0
0
0
0
0
0
510
RFP/Q Management
ComCM
0
55.00
0
0
46.00
0
0
0
0
0
0
0
TS  Operations
0
0
0
0
0
0
0
0
0
0
500
Project Management
ComOps
0
60.00
0
0
46.00
0
0
0
0
0
0
0
502
Administration
ComOps
0
60.00
0
0
46.00
0
0
0
0
0
0
0
510
RFP/Q Management
ComOps
0
60.00
0
0
46.00
0
0
0
0
0
0
0
TS  Performance
0
0
0
0
0
0
0
0
0
0
500
Project Management
ComPrfm
0
52.00
0
0
80.00
0
0
0
0
0
0
0
502
Administration
ComPrfm
0
52.00
0
0
80.00
0
0
0
0
0
0
0
510
RFP/Q Management
ComPrfm
0
52.00
0
0
80.00
0
0
0
0
0
0
0
DESIGN
0
$0
0
$0
$0
$0
$0
$0
$0
$0
TS  Engineering
0
0
0
0
0
0
0
0
0
0
534
COM Network Design
ComEng
0
55.00
0
0
65.00
0
0
0
0
0
0
0
536
COM Network Drafting
ComEng
0
38.00
0
0
65.00
0
0
0
0
0
0
0
TS  Infrastructure
0
0
0
0
0
0
0
0
0
0
532
COM Fiber Design
ComFiber
0
45.00
0
0
46.00
0
0
0
0
0
0
0
533
COM Fiber Drafting
ComFiber
0
45.00
0
0
46.00
0
0
0
0
0
0
0
530
COM Inf Design
ComWrls
0
45.00
0
0
42.00
0
0
0
0
0
0
0
531
COM Inf Drafting
ComWrls
0
45.00
0
0
42.00
0
0
0
0
0
0
0
CONSTRUCTION
320
$14,400
0
$0
$0
$0
$0
$0
$0
$14,400
$35,884
$50,284
Materials
0
0
0
0
0
0
TS  Engineering
0
0
0
0
0
0
0
0
0
0
553
COM Network Const
ComEng
0
55.00
0
0
65.00
0
0
0
0
0
0
0
TS  Infrastructure
320
14,400
0
0
0
0
0
14,400
35,884
50,284
556
COM Const Inspection
ComFiber
0
45.00
0
0
46.00
0
0
0
0
0
0
0
552
COM Fiber Construction
ComFiber
0
45.00
0
0
46.00
0
0
0
0
0
0
0
555
COM Const Support
ComWrls
320
45.00
14,400
0
79.00
0
0
0
0
14,400
35,884
50,284
556
COM Const Inspection
ComWrls
0
45.00
0
0
60.00
0
0
0
0
0
0
0
550
COM Inf Ancillary ConstructioComWrls
0
45.00
0
0
46.00
0
0
0
0
0
0
0
551
COM Inf Civil Construction
ComWrls
0
45.00
0
0
46.00
0
0
0
0
0
0
0
TS  C&M
0
0
0
0
0
0
0
0
0
0
553
COM Network Const
ComCM
0
55.00
0
0
46.00
0
0
0
0
0
0
0
553
COM Network Const
ComRADIO
0
47.00
0
0
20.00
0
0
0
0
0
0
0
Non-Telecommunication Systems Work **
0
$0
0
$0
$0
$0
$0
$0
$0
$0
$0
$0
540
MCM - Fabrication
Other
0
0
0
0
0
0
0
0
0
0
539/559
Other 1
Other
0
0
0
0
0
0
0
0
0
0
539/559
Other 2
Other
0
0
0
0
0
0
0
0
0
0
539/559
Other 3
Other
0
0
0
0
0
0
0
0
0
0
539/559
Other 4
Other
0
0
0
0
0
0
0
0
0
0
539/559
Other 5
Other
0
0
0
0
0
0
0
0
0
0
539/559
Other 6
Other
0
0
0
0
0
0
0
0
0
0
539/559
Other 7
Other
0
0
0
0
0
0
0
0
0
0
539/559
Other 8
Other
0
0
0
0
0
0
0
0
0
0
INSTALLATION RECORD
0
$0
0
$0
$0
$0
$0
$0
$0
$0
560
ComTOOLS Update
ComOps
0
60.00
0
0
65.00
0
0
0
0
0
0
0
605
Job Closing
ComEng
0
55.00
0
0
65.00
0
0
0
0
0
0
0
605
Job Closing (Drafter)
ComEng
0
38.00
0
0
65.00
0
0
0
0
0
0
0
605
Job Closing
ComFiber
0
45.00
0
0
65.00
0
0
0
0
0
0
0
605
Job Closing
ComWrls
0
45.00
0
0
65.00
0
0
0
0
0
0
0
605
Job Closing
ComPrfm
0
52.00
0
0
65.00
0
0
0
0
0
0
0
Grand Total
320
$14,400
0
$0
$0
$0
$0
$0
$0
$14,400
$35,884
$50,284
DEFINITIVE ESTIMATE SUMMARY
Project: Stewart Mtn Dam County Estimate  - Stewart Mtn Dam Inspector Estimate
LABOR
STAFF AUG
MATERIALS*
Stewart Mtn Dam construction inspector Estimate 2-12-2019.xlsx
2/12/2019

EXHIBIT “D”  
 
COUNTY-SRP Connection Diagram 
 
Attached diagram prepared by  
SRP Telecommunication Systems Engineering

STWEART MTN COUNTY CABINET  
(COUNTY)
ACCESS, AC POWER (HYDRO 
INVOLVEMENT)
SRP
NETWORK
LEGEND:
SRP RESPONSIBILITY
COUNTY RESPONSIBILITY 
UPDATED BY SRP ON 2‐6‐2020
POLE SPLICE BY SRP
POLE SPLICE BY SRP
5 Mbps
10 Mbps
TORTILLA FLAT (COUNTY)
ROUTER
SW
MIW
CANYON LAKE (COUNTY)
MIW
SW
ROUTER
FISH CREEK (COUNTY)
ROUTER
COUNTY SRP CONNECTION DIAGRAM. VSD
KYRENE REGEN (SRP)
FP
KYRENE 500 CONTROL HOUSE (SRP)
NEW 
ROUTER
MUX
FP
2 DS1s
15 Mbps
NEW
FP
KYRENE  (COUNTY)
NEW
FP
ROUTER
NEW FIBER
2 FIBERS
18 Mbps
STEWART MTN DAM COMM ROOM (SRP)
DSX
M/W
MUX
ROUTER
2 DS1s
SW
M/W
SAGUARO LAKE  (COUNTY)
M/W
SW
ROUTER
NEW
FP
NEW
JMUX
NODE
LC
MULTIMODE
JUMPER
NEW
FP
NEW
JMUX
NODE
LC
MULTIMODE
JUMPER
SINGLEMODE
JUMPER
SC-APC

EXHIBIT “E” 
List of County and SRP Contacts and Call-In Procedures for Facility Access  
 
 
Contacts and Call-In Procedures shall be in accordance with the IGA, as amended from time to time, 
including but not limited to Section 4 (e).   
 
Feb 2019 Updated County Contacts 
DURING NORMAL BUSINESS HOURS 
6:00 AM TO 4:30 PM, MONDAY THROUGH FRIDAY 
 
CALL MARICOPA COUNTY RADIO SHOP 
 
(602) 506-1191 
DURING NON-BUSINESS HOURS, WEEKENDS AND HOLIDAYS  
 
CALL MARICOPA COUNTY ON-CALL PAGER 
 
(602) 204-9558 
WIRELESS SYSTEM MANAGER 
 
(602) 506-1193 
WIRELESS SYSTEM TECHNICAL MANAGER 
(602) 506-1229 
 
IN ADDITION, PLEASE USE THE FOLLOWING STEWART MOUNTAIN DAM SITE (THE 
“SITE”) SPECIFIC CONTACTS AND PROCEDURES. WITH RESPECT TO THIS SITE ONLY, 
IN THE EVENT OF ANY CONFLICT BETWEEN THE ACCESS PROCEDURES IN THE IGA 
AND THE BELOW SITE SPECIFIC PROCEDURES, THE BELOW PROCEDURES SHALL 
CONTROL: 
 
Limited Access Hours: Access to the Stewart Mountain Dam site (the Site), shall be limited to normal 
business hours for the Site, which are Monday through Friday, 6:00 a.m. to 4:00 p.m., excluding weekends 
and all SRP observed holidays.   
 
Access to the Site will be supervised by SRP hydro personnel, unless the County personnel or contractors 
have been issued current SRP badges, in which case, SRP can provide them access to the Site through the 
SAFE program.  Badges shall be active only during the period of construction for the specific work outlined 
in this SSSA, and shall be returned to SRP following the construction period.   
 
Please follow the below procedures to request access: 
Please provide the Site Operations and Maintenance Supervisor (contact information below), minimum one 
(1) week advance written notice for County personnel or contractors to perform, both for initial construction 
work, or for repairs or maintenance. Shorter notice requests may be approved at SRP’s sole discretion, so 
long as work can be performed and completed during regular Site hours, and SRP has the Site manned by an 
SRP employee(s).  Email notice is effective upon confirmation of receipt.  
 
Todd Morrow  
Stewart Mountain Dam - Operations and Maintenance Supervisor 
SRP Hydro Generation 
Phone: (602) 751-4515 (cell) or (602) 236-3839 
Email: Todd.Morrow@srpnet.com 
Mailing Address: EVS 113 PO Box 52025 Phoenix, AZ 85072-2025 
 
In addition, please call: 
Stewart Mountain Dam – Operations Staff 
Control Room Phone Number: (602) 236-5114

EXHIBIT “F” 
 
SRP’s Ground and Pavement Specifications 
(See attached: 
 (1) STANDARD SPECIFICATION FOR UTILITY TRENCH EXCAVATION AND 
BACKFILLING – 10 pages) and 
(2) For the asphalt use a MAG Type A trench repair from attached Detail 200-1 (1 page) 
with a 9 inch depth pavement section (6”ABC and 3” thick asphalt). Use A-1/2 or R ¾ mix.

SALT  RIVER  PROJECT 
 
STANDARD  SPECIFICATION 
FOR 
UTILITY TRENCH EXCAVATION AND BACKFILLING 
(SRP 02224) 
TABLE  OF  CONTENTS 
 
SECTION 
TITLE 
PAGE 
 
 
 
1.0 
GENERAL 
1 
1.1 
Work Specified Herein 
1 
1.2 
Reference Standards 
1 
1.3 
Definition of Rock 
2 
1.4 
Bluestake and Clearances 
2 
1.5 
Protection of Structures 
2 
 
 
 
 
 
 
2.0 
PRODUCT 
2 
2.1 
Backfilling/Bedding Material 
2 
 
 
 
 
 
 
3.0 
EXECUTION 
3 
3.1 
General 
3 
3.2 
Excavation 
4 
3.3 
Bedding 
5 
3.4 
Backfilling 
5 
3.5 
Field Quality Control 
6 
3.6 
Compaction 
6 
3.7 
Cleanup 
7 
 
 
Appendix A: Blasting and Vibration Requirements (2 pages) 
 
 
 
 
 
 
 
Prepared By:  Peter Kandaris_______ 
Reviewed By:________________________

SRP 02224                                                                                                    Page 1 of 7 
SALT  RIVER  PROJECT 
 
STANDARD  SPECIFICATION 
FOR 
UTILITY TRENCH EXCAVATION AND BACKFILLING 
(SRP 02224) 
 
 
1.0 
GENERAL 
 
1.1 
 Work Specified Herein 
 
This specification covers the furnishing of all labor, materials and equipment 
necessary to complete trench excavation, backfilling, compaction and related 
items. Excavation for structures such as manholes, inlets, transition structures, 
junction structures, vaults, valve boxes, catch basins, etc., shall meet the 
requirements of this specification. 
 
1.2 
Reference Standards 
 
1.2.1 Reference to standards and/or specifications herein shall be interpreted to 
mean the latest revision unless noted otherwise. The following abbreviations 
appear in this Specification: 
 
 
ASB  
Aggregate Slurry Backfill 
 
 
ASTM  
American Society for Testing and Materials 
 
 
LMB  
Lean Mix Backfill (cement stabilized slurry backfill) 
 
 
OSHA  
Occupational Safety and Health Administration 
 
 
SRP  
Salt River Project (Standard Specifications) 
 
1.2.2   The following standards shall be made a part of this Specification: 
 
ASTM D698 
Test Methods for Moisture-Density Relations of Soils 
and Soil-Aggregate Mixtures Using 5.5 lb. (2.48 kg) 
Rammer and 12-in. (305 mm) Drop (Standard Proctor)  
 
SRP 02270  
Salt River Project Standard Specification for Slurry 
Backfill Materials 
 
SRP 02230  
Salt River Project Standard Specification for Aggregate 
Base, Select and Surface Aggregate Materials

SRP 02224                                                                                                    Page 2 of 7 
1.2.3 Permission for deviation from these standards and/or specifications must 
be approved in writing by the Engineer prior to award of Contract. 
1.3 
Definition of Rock 
1.3.1 Rock shall be defined as materials, including boulders and granite, that 
cannot be removed by conventional earth moving or ripping equipment and 
require removal by techniques such as drilling and blasting/splitting or 
jackhammering. 
1.3.2  Material shall not be considered rock when it is disintegrated, weathered, 
loose or fractured to such an extent that it works and handles like soil. 
1.3.3  Rock encountered during construction shall be determined and agreed on 
by Contractor and the Engineer. Contractor shall note location of rock 
encountered during excavation on installation record drawings. 
1.4 
Bluestake and Clearances 
Maintain underground and overhead utilities in continuous service unless prior 
approval has been obtained from the Engineer. Locate, safeguard and maintain 
conflicting utilities shown on drawings and identified in field. Comply with state 
and local Blue Stake requirements for locating all utilities, including private lines. 
Utility lines identified prior to excavation work which are damaged by Contractor 
shall be repaired at Contractor's expense. Contractor shall identify conflicts by 
potholing for true depths and is responsible for relocation work needed to resolve 
conflicts. 
1.5 
Protection of Structures 
1.5.1 Take necessary precautions to protect buildings, foundations and 
structures against damage. Contractor shall be liable for all damage.  
1.5.2  Provide necessary support systems to meet all federal and state OSHA 
requirements for maintaining the stability of structures adjacent to excavations 
and excavation activities. 
2.0   PRODUCT 
 
2.1 
Backfill/Bedding Material 
 
2.1.1  Class D:  Native material with a maximum of 50% (by weight) retained on 
the 3/4-inch (19mm) sieve, free from broken concrete, timber, roots, and other 
debris. The suitability of this material shall be approved by the Engineer. 
 
2.1.2  Class C: Processed granular material (aggregate base material) meeting 
the requirements of SRP 02230.

SRP 02224                                                                                                    Page 3 of 7 
2.1.3 Electric Conduit: Native soil free from broken concrete, timber, roots or 
other debris; processed granular material (aggregate base or select material); 
ASB or LMB. Backfill within 6 inches (152mm) of conduit shall have no solid 
material with sharp edges greater than 1-½ inches (38mm) in maximum 
dimension and contain more than 50% passing the 3/8-inch (9.53mm) sieve. The 
balance of the trench backfill shall have no solid material with sharp edges 
greater than 4 inches (102mm) in maximum dimension and contain more than 
50% passing the 3/8-inch (9.53mm) sieve. 
 
2.1.4 Direct Burial Cable: Backfill within 6 inches (152mm) of the cable shall be 
processed sand or native material free of angular (sharp) rocks, broken concrete, 
timber, roots or other debris, which contains no particles larger than 3/8-inch 
(9.5mm) in greatest dimension. The balance of the trench backfill shall be native 
soil free from broken concrete, timber, roots or other debris, or processed 
granular material (aggregate base or select material), with no solid material with 
sharp edges greater than 4 inches (102mm) in maximum dimension and contain 
more than 50% passing the 3/8-inch (9.53mm) sieve. 
 
2.1.5 Gas Pipe: Processed granular or sand material free of broken concrete, 
timber, roots or other debris, which contains no particles larger than 1/8-inch 
(3.2mm) in greatest dimension. 
 
2.1.6  Aggregate Slurry Backfill (ASB): Material meeting the requirements of SRP 
02227 (SRP Stock Code No. 00-0100).  
 
2.1.7  Lean Mix Backfill (LMB): Material meeting the requirements of SRP 02227. 
Unless otherwise specified, LMB ½-sack (SRP Stock Code No. 00-0104) shall be 
used for slurry applications with trench backfill. 
 
2.1.8 Unless otherwise specified, processed granular material shall be aggregate 
base or select material meeting the requirements of SRP 02230. 
 
2.1.9 Unless otherwise specified or noted on the plans, backfill shall be native 
material that is stable, meets compaction requirements and is acceptable to the 
Engineer. Unsuitable materials include silt and clay soils with a moisture content 
so significantly over optimum that they cannot be compacted to the required 
maximum density. Sod, matted or decayed vegetation, expansive soil and other 
deleterious material are also considered unsuitable backfill material and shall be 
removed from the jobsite. 
 
3.0 
EXECUTION 
 
3.1 
General 
 
3.1.1 Use excavation shoring, bracing, sheeting, barricading and plating 
necessary to perform work and protect excavation and personnel as required for

SRP 02224                                                                                                    Page 4 of 7 
safety and conformance to governing law, including OSHA Construction 
Standards, Subpart P, and Salt River Project Excavation Safety Resource 
Manual. Cost of protection systems shall be included in Contractor bid price. 
 
3.1.2  Sawcutting of the concrete and asphalt shall be required for trenches in 
paved streets, alleys, driveways, sidewalks, etc. Sawcuts shall be to the full 
depth of the material, leaving neat, vertical, true lines in such a manner that 
adjoining surfaces will not be damaged. 
 
3.1.3 Maximum continuous length of open trench shall not exceed the 
requirements of the governing municipality. A trench shall be considered open 
until backfilled to the top of subgrade on unsurfaced areas and the top of base 
course on pavements. 
 
3.1.4  Trenches crossing streets shall be backfilled as soon as possible after 
placement of conduit, pipe or structures. Substantial steel plates with adequate 
trench bracing shall be used to bridge across trenches at street crossings where 
backfill and patching have not been completed during work hours. 
 
3.1.5  Provide safe and convenient passage for pedestrians. Maintain access to 
hospitals, fire stations, fire hydrants at all times. The Engineer retains the option 
to designate a passage to be provided at any point he deems necessary. 
 
3.2 
Excavation 
 
3.2.1 Excavations for utility trenches shall conform to the dimensions, elevations, 
grades and tolerances indicated, with allowances for minimum required bedding 
width, accommodation of compaction equipment and erection of forms. Lines and 
grades shall be established prior to excavating. 
 
3.2.2 If excavation is carried beyond the dimensions, elevations or grades 
indicated on the Drawings without the Engineer's approval (except where 
necessary to meet bedding, compaction or forming requirements), the 
overexcavated area shall be cleaned of all loose material and backfilled at the 
Contractor's expense. Backfill material and compaction requirements shall be 
specified by the Engineer.   
 
3.2.3 The trench bottom shall be level for its full width to provide uniform bearing 
and support. Excessive tooth marks shall be removed or compacted level. In 
rock, bottom of trench may be over-excavated a maximum of 6 inches (152mm) 
and filled with granular material to provide a smooth surface. Granular material 
shall be compacted to meet requirements shown on the Drawings. 
 
3.2.4 Use of explosives is generally not permitted. If explosives are to be used, 
a controlled blasting plan that meets the requirements of Appendix A must be 
submitted and approved by the Engineer prior to such use. Contractor shall

SRP 02224                                                                                                    Page 5 of 7 
comply with applicable ordinances and regulations, and shall state in his proposal 
if bid is based on use of explosives. Contractor shall be responsible for any 
damages occurring due to use of controlled blasting. 
3.2.5  Where non-blast related construction activities have the capability to cause 
vibrations of sufficient intensity to damage structures, Contractor shall meet 
vibration requirements of Appendix A. 
3.2.6 Where soil incapable of supporting the conduit, pipe or structure is 
encountered, Contractor will notify the Engineer and a determination will be 
made as to the depth of over-excavation and the type of granular fill required. 
 
3.2.7  Berm or otherwise protect trenches from surface drainage or runoff. 
 
3.3 
Bedding 
 
3.3.1  Clean trench of loose material, rocks, weld rod, or other debris prior to 
placement of bedding. 
 
3.3.2 Material upon which conduit, pipe or structure is to be placed shall be 
accurately finished and compacted to the grade or dimensions shown on the 
plans. Bedding or trench bottom shall be brought to final grade so conduit, pipe 
or structure will be continuously in contact with material on which it is placed. 
Bedding material shall be within 2% of optimum moisture and compacted to the 
required density by the specified method in 6 inch (0.15m) or smaller 
uncompacted lifts. 
 
3.3.3 Bedding material shall be as noted on the plans or in the specifications. 
 
3.4 
Backfilling 
 
3.4.1 Backfill material shall be uniformly within 2% of optimum moisture content 
prior to placement in the trench. Place backfill in level lifts simultaneously on both 
sides of the conduit, pipe or structure unless otherwise specified. 
 
3.4.2 Backfill trenches in such a manner as to prevent disturbance to the pipe or 
conduit. 
 
3.4.3 Backfill from bedding to a point approximately 6 inches (152mm) above the 
top of pipe or conduit shall be placed as follows (backfill material shall be as 
specified on the plans): 
 
(a) Native material: Place in maximum uncompacted lifts of 8 inches (0.2m) and 
compact to the required density by the specified method. Native material shall 
contain no aggregate or pieces greater than 1/3 the width of the trench on 
each side of the conduit, pipe or structure and in no case exceed 3 inches 
(76mm) in maximum dimension.

SRP 02224                                                                                                    Page 6 of 7 
 
(b) Processed granular and sand material: Place in maximum uncompacted lifts 
of 12 inches (0.3m) and compact to the required density by the specified 
method. 
 
(c) ASB: Discharge directlly into the trench from the mixer, with even distribution 
on each side of conduit or pipe. ASB shall flow freely and uniformly around 
and under conduit or pipe without leaving voids. 
 
3.4.4 Backfill shall be placed from 6 inches (152mm) above top of pipe or conduit 
to finished surface as follows: 
 
(a) Unless otherwise specified, native material containing aggregate or pieces up 
to 6 inches (0.15m) in maximum dimension may be used. Under pavements, 
sidewalks, curbs, etc., pieces larger than 3 inches (0.1m) will not be allowed 
for use in the final 12 inches (305mm) below pavement base. 
 
(b) The Engineer may allow Contractor to exceed specified lift depth limits where 
Contractor demonstrates the ability to meet compaction requirements with 
proposed equipment and methods. Lift thicknesses shall not exceed that 
which can be effectively compacted by type of equipment and method used. 
 
3.4.5 When backfilling with ASB or LMB, place in lift depths that will not allow the 
conduit, pipe or structure to move (float). 
 
3.4.6 Backfill around existing utilities exposed during trench excavation in 
accordance with bedding methods, Section 3.3. 
 
3.5 
Quality Control 
 
3.5.1  Inspection and compaction tests are required on trench beddings and 
backfills unless LMB slurries are used. 
3.5.2  Density and moisture content will be verified during construction by the 
Engineer at no cost to Contractor. Test will be made at the discretion of the 
Engineer. Retesting for non-compliance shall be at Contractor's expense. 
3.5.3  Do not cover lifts before compaction tests are performed. If lifts are 
covered prior to testing, excavate test pits for making density tests on lower 
portions of backfill at instruction of the Engineer. Refill and compact test pits in 
accordance with the specifications. Excavating, refilling and compacting test pits 
shall be at Contractor's expense. 
3.6 
Compaction

SRP 02224                                                                                                    Page 7 of 7 
3.6.1 Trench bedding and backfill shall be thoroughly compacted to no less than 
the following percentage of maximum density specified in accordance with ASTM 
D698. 
 
 
Compaction 
Type 
 
 
Location 
From 
Surface to 
2' (0.6m) 
Below 
Surface 
From 2' (0.6m) 
Below Surface 
to 1' (0.3m) 
Above top of 
Pipe/Conduit 
From 1' (0.3m) 
Above Top of 
Pipe/Conduit to 
Bottom of 
Trench 
I 
Under or within 2' (0.6m) 
of existing or proposed 
pavement, curb, gutter 
or sidewalk, or when any 
part of the trench 
excavation is within 2' 
(0.6m) of the above 
Granular: 
100% 
 
Non-
Granular: 
95% 
90% (1) 
 
 
90% (1) 
II 
On utility easement in 
street, road or alley 
right-of-way outside 
limits of I. 
85% 
85% 
90% (1) 
III 
Around any structure, 
exposed utilities and in 
overexcavated areas 
95% 
95% 
95% 
IV 
All other areas 
80% 
80% 
80% 
 
Note (1): 95% for projects administered by Arizona Department of Transporation, or for projects 
within City of Phoenix rights-of-way. 
 
3.6.2  Consolidation of backfill by flooding or jetting is permitted only with prior 
assessment by and written approval of the Engineer. 
3.6.3  Mechanical compaction shall not be used within 6 inches (152m) of 
electrical cable or conduit. 
 
3.7 
Cleanup 
 
3.7.1 Adjacent grades will be dressed as needed to leave in a workmanlike 
appearance. 
 
3.7.2 All pavement, sidewalks, curbs or other surfaces which were broken or cut 
into during construction shall be repaired in kind to the satisfaction of the 
Engineer. The cost of this repair shall be included in the excavation unit price bid.

SRP 02224                                                                                                    Page A1 of 2 
SALT RIVER PROJECT 
 
APPENDIX A: 
SUPPLEMENTAL SPECIFICATION TO SRP 02220 & 02224 
 
BLASTING AND VIBRATION REQUIREMENTS 
 
 
1.0 
GENERAL 
 
This Supplemental Specification augments the requirements to SRP 02220 & 
SRP 02224 for controlled blasting and monitoring of vibration. 
 
2.0 
SUBMITTALS  
 
Submit the following items to the Engineer for review prior to blasting: 
(a) Blasting contractor name, contact person and telephone number. 
(b) Blasting plan (include methods, dates, area of blast, etc.). 
(c) Maximum weight of explosives per delay  and anticipated blast wave 
frequency. 
(d) Measured distance from nearest explosion to structures (including poles, 
building foundations, slabs, paved streets, canals, etc.). 
3.0 
PRE-BLAST SURVEY 
Contractor shall make a pre-blast survey of structures within 300 feet (91m) of 
the blast site and provide the Engineer with a survey report a minimum of ten 
days prior to commencement of blasting. Report shall contain the following: 
(a) List of properties and owners of record within 300 feet (91m) of blast site. 
(b) List of property owners contacted, date and method of contact. 
(c) Drawings, photographs and other documentation of existing cracks and 
damage to structures on listed properties. 
(d) List of properties not inspected and reason(s) for not performing inspections. 
4.0 
MONITORING AND PRACTICES 
Monitor blasting using minimum of two on-site seismographs as detailed in 
paragraph 25.C.04 of "The Blasting Guidance Manual," prepared by the Office of 
Surface Mining Reclamation and Enforcement, United Stated Department of the 
Interior (dated 10/1/87). Energy ratio recorded by a three-component

SRP 02224                                                                                                    Page A2 of 2 
seismograph shall not exceed 1.00 and peak particle velocity shall not exceed 
2.00 inches (51mm) per second.  
Allow enough time between tests and production blasting to make adjustments in 
weight per delay of explosives used. 
Use blasting practices which ensure that no flyrock reaches structures. Do not 
use metal blasting mats within 200 feet (61m) of electric power lines. 
Monitor other construction vibrations which may be of sufficient intensity to cause 
damage to buildings or structures in accordance with the requirements of this 
appendix.