Extracted text (via pymupdf)
4733 characters
ZONE X (SHADED) ZONE A ZONE A ZONE AE ZONE X (SHADED) ZONE AE ZONE AE ZONE AE ZONE AE ZONE AE ZONE AE ZONE A ZONE X (SHADED) ZONE X (SHADED) ZONE X (SHADED) ZONE AE ZONE AE ZONE AE ZONE AE ZONE AE 1 1 1 1 1 8 2 2 2 2 2 2 3 3 3 3 3 3 3 6 6 2 5 4 BUILDING 1 16 UNITS BUILDING 2 16 UNITS CLUBHOUSE BUILDING 3 16 UNITS BUILDING 4 16 UNITS BUILDING 5 16 UNITS BUILDING 6 16 UNITS BUILDING 7 16 UNITS BUILDING 8 16 UNITS BUILDING 9 16 UNITS BUILDING 10 16 UNITS BUILDING 11 16 UNITS BUILDING 12 16 UNITS BUILDING 13 8 UNITS BUILDING 14 8 UNITS date phase/rev scale NOT FOR CONSTRUCTION OR RECORDING PRELIMINARY REVISION # © 2024 STUDIO MA This document is an instrument of service and shall remain the property of the Architect, who shall retain all common law, statutory and other reserved rights, including the copyright thereto. project name address client GORMAN & COMPANY 608 East Missouri Ave. Phoenix, AZ 85012 4035 E Indian School Rd. Phoenix, Arizona 85018 602 251 3800 sma project no. 1"=40'-0" 2024.12.02 DESIGN DEVELOPMENT A0-01 SITE PLAN WICKENBURG APARTMENTS Wickenburg, AZ 24-203 GENERAL SITE PLAN NOTES 1. REFER TO GENERAL INFORMATION SHEET FOR GENERAL NOTES, ABBREVIATIONS, SYMBOLS, AND LEGENDS. 2. ALL DIMENSIONS TO EXISTING CONDITIONS SHALL BE VERIFIED IN FIELD. 3. REFER TO LANDSCAPE DRAWINGS FOR PLANTING PLAN AND HARDSCAPE. 4. REFER TO CIVIL DRAWINGS FOR SITE STORMWATER SYSTEM INFORMATION AND FINISH GRADES. 5. REFER TO UTILITY DRAWINGS FOR UTILITY INFORMATION. 6. ALL NEW OR RELOCATED UTILITIES WILL BE PLACED UNDERGROUND. 7. ALL ROOFTOP EQUIPMENT WILL BE SCREENED TO THE HEIGHT OF THE TALLEST PIECE OF EQUIPMENT. 8. THE DEVELOPMENT AND USE OF THIS SITE WILL CONFORM WITH ALL APPLICABLE CODES AND ORDINANCES. 9. ANY LIGHT WILL BE PLACED SO AS TO DIRECT THE LIGHT AWAY FROM ADJACENT RESIDENTIAL DISTRICTS AND WILL NOT EXCEED ONE FOOT CANDLE AT THE PROPERTY LINE. NO NOISE, ODOR, OR VIBRATION WILL BE EMITTED SO THAT IT EXCEEDS THE GENERAL LEVEL OF ALLOWANCE EMITTED BY USES OUTSIDE THE SITE. 10. AFTER FINAL APPROVAL THE PROJECT WILL BE INSPECTED FOR ZONING COMPLIANCE DURING CONSTRUCTION AND PRIOR TO OCCUPANCY. THE APPLICANT IS TO NOTIFY THE AHJ INSPECTION AUTHORITY PRIOR TO OCCUPANCY TO ARRANGE FOR INSPECTIONS. 11. SUBSURFACE INVESTIGATION: SUBSURFACE WORK SHALL BE COORDINATED THROUGH THE LOCAL AHJ AND/OR WASH U. SUCH WORK SHALL BE PERFORMED BY AN INDEPENDENT TESTING AGENCY. 12. SITE CLEARING: CONTRACTOR TO RESTORE OR REPAIR ANY DAMAGED SIDEWALKS, CURBS, UTILITIES, OR PLANT MATERIAL. THE OWNER TO THE REVIEW REPAIR WORK WITH THE CONTRACTOR AND APPROVE PRIOR TO FINAL ACCEPTANCE AND PAYMENT. 13. BARBED, RAZOR, OR CONCERTINA WIRE (OR SIMILAR) SHALL NOT BE USED ON THIS SITE WHERE VISIBLE FROM PUBLIC STREETS OR ADJACENT RESIDENTIAL AREA. 14. ALL SERVICE AREAS SHALL BE SCREENED TO CONCEAL TRASH CONTAINERS, LOADING DOCKS, TRANSFORMERS, BACKFLOW PREVENTERS AND OTHER MECHANICAL OR ELECTRICAL EQUIPMENT FROM EYE LEVEL ADJACENT TO ALL PUBLIC STREET. 15. ALL EXISTING VEGETATION, STRUCTURES, SITE IMPROVEMENTS AND EQUIPMENT NOT DESIGNATED FOR DEMOLITION SHALL BE PROTECTED IN PLACE - COORDINATE WITH OWNER FOR PROTECTION REQUIREMENTS AND/OR TEMPORARY RELOCATION. KEYNOTES - SITE PLAN 1. PAVED DRIVE AISLE 2. PAVED SIDEWALK 3. PAVED PARKING STALL 4. BBQ / AMENITY AREA 5. PLAYGROUND 6. SOLID WASTE ENCLOSURE w/ 6FT HIGH WALLS & GATES 7. ELECTRICAL TRANSFORMER ON PAD 8. MAILBOX CLUSTER GOVERNING CODES ALL CODES AS PER THEIR ADOPTING ORDINANCE(S) WITH AMENDMENTS: 2018 IBC, IMC, IFC, IPC, 2017 NEC, 2006 IECC 2018 MAG STANDARDS TOWN OF WICKENBURG TOWN CODE AND ZONING ORDINANCE, LATEST SECTION 504 OF THE REHABILITATION ACT OF 1973 (HUD) FAIR HOUSING ACT, AS AMENDED HOME REGULATIONS INCLUDING HUD HOUSING QUALITY STANDARDS MARICOPA COUNTY HOUSING REHABILITATION STANDARDS ARIZONA DEPARTMENT OF HOUSING, QUALIFIED ALLOCATION PLAN - MANDATORY DESIGN STANDARDS (EXHIBIT A) 2006 IECC REQUIREMENTS climate zone fenes- tration u-factor skylight u- factorb glazed fenestration shgc ceiling r- value wood frame wall r-value mass wall r- value floor r- value TABLE 402.1.1 - INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa 2 0.75 0.75 0.40 30 13 4 13 a. r-values are minimums. u-factors and shgc are maximums. r-19 shall be permitted to be compressed into a 2x6 cavity. b. the fenestration u-factor column excludes skylights. the shgc column applies to all glazed fenestration. UNIT & PARKING CALCULATIONS PARKING UNIT TYPE COUNT RATIO REQUIRED PROVIDED 1 BEDROOM 104 1.5 156 2 BEDROOM 78 1.5 117 3 BEDROOM 26 1.5 39 TOTAL 208 354 354* * NOTE: INCLUDES REQUIRED ACCESSIBLE PARKING STALLS PARCEL INFORMATION PARCEL A, LOT 5, APN #505-38-005 PARCEL A, LOT 18, APN #505-38-026A PARCEL B, TRACT 1, APN #505-38-112