Report to the Board of Adjustment
Prepared by the Maricopa County Planning and Development Department
Case:
BA250040 – Little Property
Hearing Date:
July 17, 2025
Supervisor District:
3
____________________________________________________________________________________________
Applicant:
Lance Little, Little Investments, LLC
Property Owner:
Lance Little
Request:
Variance to the development standard of the Maricopa County Zoning
Ordinance to permit:
1)
Proposed building height of 32’ where 30’ is the maximum permitted per
MCZO Article 503.3
Site Location:
APN 210-11-001D @ 25847 N. 19th Ave. – 19th Ave. and Jomax Rd., in the
Phoenix area
Site Size:
76,851 sq. ft.
Current Use / Zoning:
Single-family residence / Rural-43
Background:
1.
Unknown: A lot split of the parent parcel created the subject lot.
2.
October 6, 2019: The current owner took possession of the subject property.
3.
December 31, 2024: Residential building permit for a 12,906 SF shop was finalized, with a condition
that the building is not to be used for commercial purposes (B202014260).
4.
February 10, 2025: Property owner applies for residential building permits to demolish existing
home and construct a brand new residence in the same location. During the review process the
property owner was informed that the proposed home exceeds the maximum height for this
zoning district (BLDR2500757).
5.
May 29, 2025: Property owner submits the subject variance request (BA250040).
Existing On-Site and Surrounding Zoning/Land Use:
6.
On-site:
Rural-43 / Single-family residence
North:
Rural-43 / Single-family residence
South:
Rural-43 / Single-family residence
East:
Rural-43/ Single-family residence
West:
19th Ave. then Norterra PUD (Phoenix) / Single-family residences
Page 2 of 8
Variance Request:
7.
The applicant proposes to demolish the existing home on the lot and replace it with a 6,159 SF
single family residence. The current plan is to add earthen fill to part of the building pad , which
will increase the height of the home to 32’ above the natural grade of the lot. Since the maximum
height in the Rural-43 zoning district is 30’ above natural grade on subdivided land, the applicant
is requesting a variance to increase the maximum height on this parcel to 32’ above natural grade.
The applicant’s architect believes that the addition of earthen fill is necessary to address slight
undulations on this lot and create the aesthetic appearance of the new home.
Excerpt from proposed site plan & elevations
Page 3 of 8
Photographs of subject site
Site Analysis:
8.
The site is a rectangular lot that appears to be mostly flat without any washes or steep elevations
on site. This is an area full of rural residential land uses; however, across 19th Ave. to the west is
a more moderate-density suburban residential development. This part of Deer Valley is relatively
flat with typical Lower Sonoran Desert flora.
Page 4 of 8
Aerial photo of subject site
Aerial image & surrounding environs
Page 5 of 8
Eagle view of subject site looking south from the north into subject parcel (aerial image dated March ‘25).
Zoning District map
Page 6 of 8
Zoning District Standards:
9.
The following table is included to illustrate and contrast the standards for the underlying zoning
district with those proposed by the owner (Note: changes to proposed standards are indicated in
bold).
Standard
Rural-43
Zoning
District
Proposed with
Variance
Min. Front Yard Setback (residence to west property line)
40-feet
40-feet
Min. Rear Yard Setback (residence to east property line)
40-feet
364-feet
Min. Side Yard Setback (residence to north property line)
30-feet
30-feet
Min. Side Yard Setback (residence to south property line)
30-feet
32-feet
Maximum Height (above the natural grade)
30-feet
32-feet
Minimum Lot Area
43,560-sq. ft.
76,851-sq. ft.
Minimum Lot Width
145-feet
165-feet
Maximum Lot Coverage
25%
24.7%
Note: Standards indicated in bold do not meet base zoning standards
State Statute / County Zoning Ordinance Tests - ARS § 11-816.B.2 and MCZO Article 303.2.2 states the
Board of Adjustment may, “Allow a variance from the terms of the ordinance if, owing to peculiar
conditions, a strict interpretation would work an unnecessary hardship and if in granting the variance the
general intent and purposes of the zoning ordinance will be preserved.”
10.
Statutory Test -1 Does the applicant’s property contain any peculiar condition– Discuss and
explain what the peculiar conditions is/are facing the property and include reference to the
Maricopa County Zoning Ordinance Regulations or Development Standards to be varied.
“The subject property, located at 25847 N. 19th Avenue in unincorporated Maricopa County, is
zoned RU-43 and subject to MCZO Article 503.3, which limits the maximum building height to 30
feet measured from natural grade. Due to natural grade variations, architectural transitions, and the
intent to create a unified and consistent elevation across existing and new structures on the site,
strict enforcement of this regulation results in a technical exceedance of approximately 1 foot at
the highest points of the proposed residence. The property exhibits slight topographical changes,
and the design incorporates a continuous architectural language across all structures, including a
previously approved garage. To preserve that consistency, the residence was designed with similar
rooflines and massing. These conditions—specifically, the topographic variation and the integration
of prior structures—are not common to all RU-43 parcels and represent a peculiar condition
affecting the property's development potential. Requiring strict adherence to the 30-foot standard
would necessitate substantial redesign to lower the home by a few inches, impacting ceiling
heights, structural systems, and exterior elevations, thereby diminishing the architectural cohesion
of the site and imposing an undue burden on the property owner.”
11.
Statutory Test 2 – Does applying the requirements of the Ordinance to the applicant’s property
create an Unnecessary Hardship – Explain how the peculiar condition identified in #1 causes an
unnecessary hardship to the property when the requirements of the Maricopa County Zoning
Ordinance are applied. Explain how the that the peculiar condition of the property came to be and
whether the condition was created by the applicant or someone in the property’s line of title.
Explain the proposed use of the property with the variance request. Identify and explain all
peculiar conditions on your property in regard to the following areas: slope, narrowness,
Page 7 of 8
shallowness, irregular shape, location, washes, vegetation, and easements, etc. Explain how
enforcement of the Zoning Regulations or Development Standards would impose a hardship on
the property.
“The unnecessary hardship arises from how the height standard is measured against natural grade
on an unsubdivided lot with minor but meaningful slope variations. The proposed residence was
developed in good faith to conform with RU-43 development standards. The slight overage—limited
to parapet or ridge conditions—is a result of how the home integrates with existing architectural
elements on the property. This condition was not self-imposed and did not originate from any action
within the line of title. Rather, it was revealed late in the permitting process following a technical
zoning review. By that point, architectural and engineering plans had been completed based on
industry-standard interpretations and previously permitted adjacent construction. A strict
enforcement of the height regulation would require a complete reworking of the building’s structural
systems and elevations to resolve a dimensional variance of less than 12 inches, creating
disproportionate cost, delay, and design disruption relative to the minor nature of the
nonconformity.”
12.
Statutory Test 3 – General Intent and Purpose of the Zoning Ordinance – Discuss the purpose
of the zoning requirement from which the variance is being sought. Then, discuss and explain
how, provided statutory tests #1 and #2 are satisfied, the granting of the requested variance
would preserve the general intent and purpose of the Zoning Ordinance.
“The requested variance is fully consistent with the intent of the RU-43 zoning ordinance, which
aims to maintain rural residential character, control massing, and promote compatible
development. The residence complies with all other applicable zoning standards, including
setbacks, lot coverage, permitted uses, and building orientation. The height variance requested is
limited to 1 foot, and only at select points of measurement relative to natural grade. The home is
located on a 1.8-acre parcel, allowing generous spacing from neighboring lots and no visual or
spatial disruption to adjacent properties. Moreover, the design reflects a coordinated effort to unify
structures on the property under a cohesive architectural scheme. The minimal height variation is
imperceptible from surrounding vantage points and will not result in any adverse effects on
neighboring property values, public safety, or overall community character.”
Findings:
13.
The applicant has the burden of proving to the Board that, in accordance with the standard set
forth in ARS §11-816.B.2 and MCZO Article 303.2.2, the property requires a variance. To grant the
relief, the applicant must prove, and the Board must find and identify, a physical condition of the
applicant’s property that is peculiar and not common to the area or the universe of the zoning
district. Also, any such peculiarity must not have been created either by the applicant or anyone
in the chain of title. If the Board determines that there is no such peculiar physical condition, its
inquiry stops, and the application must be denied.
If the Board identifies a peculiar physical condition of the applicant’s property which is not self-
imposed, then the applicant must prove, and the Board must find and identify, an unnecessary
hardship imposed upon the property due to the strict application of the requirements of the zoning
ordinance which the applicant wishes to have varied such that there is no viable use of the
property without the variance.
If the Board identifies a peculiar physical condition of the property which is not self-imposed, and
that in applying the requirements of the zoning ordinance to the property, because of the peculiar
physical condition, an unnecessary hardship exists, the applicant must prove, and the Board must
Page 8 of 8
find and identify, how the granting of the variance will preserve the general intent and purpose of
the zoning ordinance.
In order to approve the variance the Board must make findings and articulate them in motion
memorializing the above.
14.
Based upon what the applicant has submitted and the staff analysis in this report, staff offers the
following positive and/or negative observations the Board may consider in its findings:
•
After reviewing the submission, staff is unable to identify a peculiar condition of this lot
since the lot is a standard rectangular shape and relatively level without topographic
features.
•
Staff cannot identify any unnecessary hardship created by application of the ordinance
requirements that would prevent reasonable development.
•
The property owner’s plans show that the increase in building height is due to imported
fill dirt for the proposed design and thus any hardship is self-created.
•
There are alternatives available that would alleviate the self-created hardship, such as
removing the earthen fill from the building pad or lowering the west rooftop parapet over
the fill area by 18” as this feature is simply an architectural aesthetic.
15.
And further, if the Board finds the applicant has satisfied the statutory test, and has stated its
findings on the record, the grant of this variance will memorialize the following:
a)
Variance approval establishes a 32’ maximum building height for APN 210-11-001D.
Presented by:
Martin Martell, Planner
Reviewed by:
Darren V. Gérard, AICP, Planning Manager
Attachments:
Case Map (1 page)
Application / Supplemental Questionnaire (3 pages)
Site Plan (3 pages)
Building Plan Elevations (10 pages)
/
Maricopa County Planning & Development - Phoenix, AZ
3
Gross Acres: 2 approx.
Generated June 25, 2025 11:30 AM
BA250040
Application Name:
Legal Description
Little Property
Applicant
Case Address
4N 3E 6
Lance Little
25847 N 19TH AVE
Applicant Phone/Email
Parcel Primary:210-11-001D
6023150286
everett@stonecoldmasonry.com
PHOENIX, AZ 85085
Map scale 1:1,157
Supervisor District No.
Requesting 31' height variance for new home based on site grade.
Planning & Development Department
301 W. Jefferson St., Suite 170 Phoenix, Arizona 85003
P: 602.506.3301
Residential Variance Application Packet
12/2/24
RESIDENTIAL VARIANCE
PROPERTY OWNER AUTHORIZATION
APPLICATION FORM
ALL FEES ARE DUE AT TIME OF APPLICATION AND ARE NON-REFUNDABLE
RESIDENTIAL VARIANCE REQUEST
Description of Request:
Existing Zoning District and Use of Property:
Related Case Number(s):
PROPERTY INFORMATION
Address (if known):
General Location (include nearest city/town):
Size in Acres:
Square Feet:
Legal Description:
Section:
Township:
Range:
Assessor’s Parcel Number(s):
Subdivision Name (if applicable):
Is this subject property within an area of 15% or greater hillside slopes? Yes
No
APPLICANT INFORMATION
Name:
Contact:
Address:
City:
State:
Zip:
Phone #:
Fax #:
E-mail Address:
PROPERTY OWNER INFORMATION
Name:
Contact:
Address:
City:
State:
Zip:
Phone #:
Fax #:
E-mail Address:
PROPERTY OWNER AND APPLICANT AUTHORIZATION
I (property owner)
authorize (applicant’s name)
to file this application on all matters relating to this request with Maricopa County. By signing this form as the property owner I hereby agree to
abide by any and all conditions that may be assigned by the Maricopa County Board of Supervisors, Maricopa County Planning and Zoning
Commission, or Maricopa County Planning and Development Department staff as applicable, as part of any approval of this request, including
conditions, development agreements, and/or any other requirement that may encumber or otherwise affect the use of my property.
PROPOSITION 207 WAIVER – SIGNATURE REQUIRED
The property owner acknowledges that the approval being sought by this application may cause a reduction in the existing rights to use,
divide, sell or possess the private property that is the subject of this application. The property owner further acknowledges that it is the
property owner who has requested the action sought by the filing of this application. Therefore, with full knowledge of all rights granted to
the property owner pursuant to A.R.S.§1§12-1132 through 1138, the property owner does hereby waive any and all claims for diminution in
value of the property with regard to any action taken by Maricopa County as result of the filing of this application.
Property Owner Signature:
Date:
INSPECTIONS
By submitting this application, I am inviting County staff to conduct all site inspections they deem necessary.
VERIFICATION OF APPLICATION INFORMATION – SIGNATURE REQUIRED
I certify that the statements in this application and support material are true. Any approvals or permits granted by Maricopa County in reliance
upon the truthfulness of these statements may be revoked or rescinded.
Owner or Authorized Agent Signature:
Date:
ARS § 1605 TIMEFRAME EXTENSION
I authorize a 50% timeframe extension for the review of my application as adopted by the Board of Supervisors per ARS § 1605 and as
amended.
Property Owner Signature: _________________________________________________________ Date:
______________________________
Requesting 31' height variance for new home based on site grade.
25847 N 19th Avenue, Phoenix, AZ 85085
19th ave & Jomax rd.
1.80
19,023.00
3
4 north
3 east of the gila
210-11-001D
I
Lance Little / Little Investments LLC
Lance Little
416 W. Lone Cactus Dr.
Phoenix
AZ
85027
(602) 315-0286
Everett@stonecoldmasonry.com
Lance Little / Little Investments LLC
Lance Little
416 W. Lone Cactus Dr.
Phoenix
AZ
85027
(602) 315-0286
Everett@stonecoldmasonry.com
Lance Little
Lance Little
05/19/2025
RU-43
05/19/2025
05/19/2025
RECEVED 29.MAY 25
BA250040 - 1. SUB
Planning & Development Department
301 W. Jefferson St., Suite 170 Phoenix, Arizona 85003
P: 602.506.3301
Residential Variance Application Packet
12/2/24
RESIDENTIAL VARIANCE SUPPLEMENTAL QUESTIONNAIRE
ARS §11-816 B.2
The Board of Adjustment may allow a variance from the terms of the ordinance when, owing to peculiar
conditions, a strict interpretation would work an unnecessary hardship, if in granting such variance the
general intent and purposes of the zoning ordinance will be preserved.
1.
Please discuss and explain what is/are the peculiar condition(s) facing the property and include reference to the
Maricopa County Zoning Ordinance Regulation(s) or Development Standard(s) to be varied. Explain the proposed
use of the property with the variance request. Identify and explain all peculiar conditions on your property in regard
to the following areas: slope, narrowness, shallowness, irregular shape, location, washes, vegetation, and
easements, etc. Explain how enforcement of the Zoning Regulation(s) or Development Standard(s) would impose
a hardship on the property.
2.
Please explain the unnecessary hardship the Maricopa County Zoning Ordinance creates because of a peculiar
condition/the peculiar conditions on site. Please discuss and explain that the peculiar condition of the property is
not self-created in the line of title.
The subject property, located at 25847 N. 19th Avenue in unincorporated Maricopa County, is zoned RU-43 and subject to MCZO Article
503.3, which limits the maximum building height to 30 feet measured from natural grade. Due to natural grade variations, architectural
transitions, and the intent to create a unified and consistent elevation across existing and new structures on the site, strict enforcement of
this regulation results in a technical exceedance of approximately 1 foot at the highest points of the proposed residence.The property
exhibits slight topographical changes, and the design incorporates a continuous architectural language across all structures, including a
previously approved garage. To preserve that consistency, the residence was designed with similar rooflines and massing. These
conditions—specifically, the topographic variation and the integration of prior structures—are not common to all RU-43 parcels and
represent a peculiar condition affecting the property's development potential.Requiring strict adherence to the 30-foot standard would
necessitate substantial redesign to lower the home by a few inches, impacting ceiling heights, structural systems, and exterior elevations,
thereby diminishing the architectural cohesion of the site and imposing an undue burden on the property owner.
The unnecessary hardship arises from how the height standard is measured against natural grade on an unsubdivided lot with minor but
meaningful slope variations. The proposed residence was developed in good faith to conform with RU-43 development standards. The
slight overage—limited to parapet or ridge conditions—is a result of how the home integrates with existing architectural elements on the
property.This condition was not self-imposed and did not originate from any action within the line of title. Rather, it was revealed late in the
permitting process following a technical zoning review. By that point, architectural and engineering plans had been completed based on
industry-standard interpretations and previously permitted adjacent construction.A strict enforcement of the height regulation would
require a complete reworking of the building’s structural systems and elevations to resolve a dimensional variance of less than 12 inches,
creating disproportionate cost, delay, and design disruption relative to the minor nature of the nonconformity.
Planning & Development Department
301 W. Jefferson St., Suite 170 Phoenix, Arizona 85003
P: 602.506.3301
3.
Please discuss and explain how the granting of the requested variance would not cause a negative impact on
the general intent and purpose of the Zoning Ordinance.
*Additional sheets may be attached.
** DO NOT USE THIS FORM IF YOU ARE SUBMITTING AN INTERPRETATION
Residential Variance Application Packet
6/17/24
The requested variance is fully consistent with the intent of the RU-43 zoning ordinance, which aims to maintain rural residential
character, control massing, and promote compatible development.The residence complies with all other applicable zoning standards,
including setbacks, lot coverage, permitted uses, and building orientation. The height variance requested is limited to 1 foot, and only at
select points of measurement relative to natural grade. The home is located on a 1.8-acre parcel, allowing generous spacing from
neighboring lots and no visual or spatial disruption to adjacent properties.Moreover, the design reflects a coordinated effort to unify
structures on the property under a cohesive architectural scheme. The minimal height variation is imperceptible from surrounding
vantage points and will not result in any adverse effects on neighboring property values, public safety, or overall community character.
RECEVED 29.MAY 25
BA250040 - 1. SUB
PLAN &
TRUE
NORTH
NORTH ARROW
FIRST FLOOR
0'-0"
LEVEL LINE
A1
1HR
FB
WALL TYPE
FB
FIRE BARRIER
FP
FIRE PARTITION
FW
FIRE WALL
SB
SMOKE BARRIER
SP
SMOKE PARTITION
##
WINDOW TYPE
101
DOOR NUMBER
1
REVISIONS
1
COLUMN REFERENCE GRIDS
?
KEYED NOTES
CEILING HEIGHT
ROOM NAME
101
150 SF
ROOM NAME
ROOM NUMBER
ROOM AREA
TYP.
1
A101
BUILDING SECTION
WALL SECTION
TYP.
1
A101
A101
A1
EXTERIOR BUILDING ELEVATION
1 / A101
CK
INTERIOR BUILDING ELEVATION
SLOPE INDICATOR
CRICKET SLOPE INDICATOR
EXIT SIGN (CEILING MOUNTED)
EXIT SIGN (WALL MOUNTED)
GENERAL LEGEND
+ 12'-0"
A.F.F.
1/8 : 12
NOTE: REFER TO CODE SHEET FOR OCCUPANCY, ACCESSIBILITY,
AND EGRESS SYMBOLS
VICINITY MAP
W PARSONS ROAD
N 19TH AVENUE
W JOMAX ROAD
NTS
PROJECT
LOCATION
PROJECT DATA
SCOPE OF WORK
OWNER
PARCEL NUMBER:
ZONING:
FLOOD ZONE:
SITE AREA:
CODES AND STANDARDS
PROJECT INFORMATION
LITTLE INVESTMENTS, LLC
25847 N. 19TH AVENUE
PHOENIX, ARIZONA 85085
210-11-001D
RU-43
76,851 SQFT
2018 INTERNATIONAL BUILDING CODE
2018 INTERNATIONAL RESIDENTIAL CODE
2018 INTERNATIONAL PLUMBING CODE
2018 INTERNATIONAL MECHANICAL CODE
2018 INTERNATIONAL FUEL GAS CODE
2017 NATIONAL ELECTRIC CODE
2009 ICC/ANSI A117.1 WITH 2010 ADA STANDARDS AS
ADOPTED BY THE STATE OF ARIZONA (MOST
RESTRICTIVE GOVERNS)
2018 INTERNATIONAL FIRE CODE AS ADOPTED BY ARIZONA
STATE FIRE MARSHAL
25847 N. 19TH AVENUE
PHOENIX, ARIZONA 85085
JURISDICTION: MARICOPA COUNTY ARIZONA
OWNER/CONTRACTOR CONSTRUCTION OF A 9470 SQ. F, 2 STORY
SINGLE FAMILY RESIDENCE THAT INCLUDES AN ELEVATOR THAT IS
PROVIDES AN ACCESSIBLE ROUTE TO THE ROOF. THERE WILL BE A
MAXIMUM OF 10 OCCUPANTS AT A TIME AT THE RESIDENCE.
LOT COVERAGE FOR NEW RESIDENCE
FIRST FLOOR: 4,840 S.F.
COVERED PATIOS AND WALKWAY: 1,815S.F.
OVERHANG CREDIT: - 482 S.F.
SHOP: 12,850 S.F.
MAX ALLOWABLE = 76,851 S.F (LOT AREA) X 25% = 19,213 S.F.
(4,840 + 1,815 + 12,850) - 482 = 19023 S.F.
=19,023 S.F. ACTUAL < 19,213 S.F. MAX ALLOWABLE
SEPERATE PERMITS:
POOL PERMIT
SITE IMPROVEMENTS
ELEVATOR
ABBREVIATION SCHEDULE
G
CMU
CONCRETE MASONRY UNIT
DET
DETAIL
DRINKING FOUNTAIN
DOWN
DOWNSPOUT
DIAMETER
DIMENSION
DRAWING
DISPENSER/DISPOSAL
(NOT REFRIGERATED)
DWG
DIM
DISP
DN
DS
DF
DIA
CLEANOUT
CLASSROOM
CERAMIC TILE
COLD WATER
CUBIC YARD
CARPET
D
CW
CY
CT
CR
CPT
CO
HEATING/VENTILATING/
HOT WATER
INSIDE DIAMETER
INVERT ELEVATION
INSULATION
AIR CONDITIONING
I.E.
INSUL
I
HW
ID
GAUGE
GALVANIZED IRON
GLUE LAMINATED BEAM
GYPSUM
HOSE BIBB
HOLLOW CORE
HEAVY DUTY
HOLLOW METAL
HEIGHT
HARDWARE
HARDWOOD
HORIZONTAL
HC
HM
HT
HVAC
HORIZ
HD
HDWR
HDWD
GLB
H
GYP
HB
GA
GI
PNL
PANEL
POUNDS PER SQUARE INCH
POUNDS PER SQUARE INCH
POLY-VINYL CHLORIDE
PROPERTY
QUARRY TILE
Q
QT
PSI
PVC
PSF
PROP
PERFORATE (D)
PREFABRICATE (D)
ON CENTER
OUTSIDE DIAMETER
OVERHEAD/OVERHANG
OCCUPANT LOAD FACTOR
PAINT
PLATE
PLASTIC LAMINATE
PLASTER
PLUMBING
PLYWOOD
PL
PLUMB
PLYWD
PLAM
PLAS
PREFAB
PERF
P
OLF
PT
OC
OD
OH
BENCHMARK
BOTTOM
BEARING
BUILT-UP ROOF
CUBIC FOOT
CAST IRON
CONTROL JOINT
CENTIMETER
CEMENTITIOUS BACKING BOARD
CEILING
CJ
CM
CLG
CF
CI
CBB
C
BUR
BM
BOT
BRG
ARCHITECT (URAL)
ALTERNATE (IVE)
ANCHOR BOLT
AGGREGATE BASE COURSE
AIR CONDITIONING
ACOUSTICAL CEILING PANEL
ACOUSTICAL TILE (APPLIED)
ABOVE FINISHED FLOOR
BUILDING
(LAY-IN)
ARCH
B
BLDG
AFF
ALT
A/C
ACP
ACT
A
AB
ABC
FA
FIRE ALARM
FACTORY FINISH
FIRE RATED GYPSUM BOARD
FLOOR DRAIN
FIRE EXTINGUISHER
FINISH FLOOR
FIRE HYDRANT
FIRE EXTINGUISHER CABINET
FIRE HOSE CABINET
FINISH
FOOTING
FTG
FIN
FF
FH
FEC
FGB
FHC
FD
FE
FAC
EXIST (ING)
ELECTRIC (AL)
EACH
EXPANSION JOINT
EQUAL
ELECTRIC DRINKING
EXPOSED
ELEVATOR
EQUIPMENT
FOUNTAIN (REFRIGERATED)
F
EXP
EXIST
EQ
EQUIP
ELEC
ELEV
E
EA
EJ
EDF
MASONRY LINTEL
MILLIMETER
MASONRY OPENING
MISCELLANEOUS
NOT APPLICABLE
NOT IN CONTRACT
NOMINAL
NOISE REDUCTION COEFFICIENT
NOT TO SCALE
N/A
NRC
O
NTS
NIC
NOM
N
ML
MM
MO
MISC
MACHINE BOLT
MINERAL CORE
MANHOLE
MASONRY
MAXIMUM
MEDIUM DENSITY FIBERBOARD
MEDIUM
METAL
MANUFACTURER
MINIMUM
MECHANICAL
JANITOR
KNOCKOUT PANEL
MAX
MED
MH
MTL
MFR
MIN
MC
MB
MDF
MECH
K
M
MAS
KO
J
JAN
PLATE
PL
TELE
TELEPHONE
TEMPERED
TELEVISION
TOP OF CURB
TOP OF FOOTING
TOP OF MASONRY
TOP OF PAVEMENT
TOP OF WALL
TYPICAL
TV
TOF
TOM
TOP
TOW
TOC
TEMP
STAINLESS STEEL
SOUND TRANSMISSION
STORAGE
TACKBOARD
TONGUE & GROOVE
COEFFICIENT
TB
T&G
T
STOR
SS
STC
PROPERTY LINE
ROUND
P.L.
∅
U
R
REV
REVISE (D) (S) (SION)
RIGHT-OF-WAY
STORM DRAIN
SQUARE FOOT
SAFETY GLASS
SQUARE
SIMILAR
SPECIFICATION
SCHEDULE
SQ
SPEC
SIM
SF
SG
S
SD
SCHED
ROW
RADIUS
RETURN AIR (REGISTER)
ROOF DRAIN
ROOM
ROUGH OPENING
REFRIGERATOR
REF
RO
RD
RM
R
RA
W/O
WITHOUT
WATER CLOSET
WOOD
WATER HEATER
WATER RESISTANT
WINDOW
WELDED WIRE FABRIC
SYMBOLS USED AS ABBREVIATIONS
ANGLE
CENTERLINE
CHANNEL
PENNY
C
[
d
L
WWF
WH
WR
WC
WD
WDW
UNLESS NOTED OTHERWISE
VERTICAL GRAIN
VINYL COMPOSITION TILE
VERTICAL
VESTIBULE
WITH
W
W/
VG
VCT
VERT
VEST
V
UNO
ADA(AG) AMERICAN W/ DISABILITIES ACT
(ACCESSIBILITY GUIDELINES)
FIBERGLASS REINFORCED PANEL
FRP
SUSP
SUSPENDED
COLD ROLLED CHANNEL
CRC
CAST-IN-PLACE
CIP
TYP
TUBE STEEL
TS
TOOLED JOINT
TJ
MOST REMOTE POINT
MRP
SOLID CORE
SC
NUMBER
#
REFLECTED CEILING PLAN
RCP
M (CONTINUED)
OPPOSITE
OPP
GROSS SQUARE FOOT
GSF
NET SQUARE FOOT
NSF
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
DESIGN TEAM
DESIGN TEAM
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 12:18:15 PM
G001
CH
AK
01-21-2025
COVER SHEET
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
ALAN KRAVITS
CAROLINA HAROS
480-544-5145
PK ASSOCIATES, LLC
480-922-8854
KENNELY & ASSOCIATES
602-612-4822
NOE ENGINEERING
602-368-8489
AFORA DESIGN LLC
480-322-9760
STRUCTURAL
MECHANICAL
CIVIL
LANDSCAPE
PEARSON ASSOCIATES
602-264-0837
PLUMBING
ELECTRICAL/LIGHTING
DICK SANTISTEVAN
602-918-8511
OWNER / CONTRACTOR
LANCE LITTLE
602-469-6261
PERMIT SUBMISSION
SHEET NO.
SHEET NAME
COVER
G001
COVER SHEET
CIVIL
C-1
GRADING AND DRAINAGE PLAN
C-2
GRADING AND DRAINAGE PLAN
C-3
CROSS-SECTIONS, NOTES AND
BUILDING DIMENSIONS
ARCHITECTURAL
A100
OVERALL FLOOR PLAN - FIRST FLOOR
A101
EXTERIOR COLUMN LOCATIONS
A102
OVERALL FLOOR PLAN - SECOND
FLOOR
A104
WALL TYPES
A200
OVERALL REFLECTED CEILING PLAN -
FIRST FLOOR
A201
OVERALL REFLECTED CEILING PLAN -
SECOND FLOOR
A300
OVERALL ROOF PLAN
A400
EXTERIOR ELEVATIONS
A401
EXTERIOR ELEVATIONS
A500
BUILDING SECTIONS
A600
WALL SECTIONS & DETAILS
A700
DOOR SCHEDULE, DOOR TYPES, &
DOOR FRAME TYPES
A702
DOOR AND WINDOW DETAILS
A800
VERTICAL CIRUCLATION - STAIRS
A801
1ST FLOOR ENLARGED PLANS &
ELEVATIONS
A802
2ND FLOOR ENLARGED PLANS &
ELEVATIONS
STRUCTURAL
S100
GENERAL STRUCTURAL NOTES
S101
GENERAL STRUCTURAL NOTES
S200
FOUNDATION PLAN
S210
SECOND FLOOR FRAMING PLAN
S220
ROOF FRAMING PLAN
S230
ROOF FRAMING PLAN
S300
TYPICAL CONCRETE DETAILS
S301
TYPICAL CONCRETE DETAILS
S302
TYPICAL MASONRY DETAILS
S303
TYPICAL STEEL DETAILS
S400
FOUNDATION DETAILS
S401
FOUNDATION DETAILS
S500
FRAMING DETAILS
S501
FRAMING DETAILS
S502
FRAMING DETAILS
S503
FRAMING DETAILS
MECHANICAL
M1
LEVEL 1 MECHANICAL
M2
LEVEL 2 MECHANICAL
M3
MECHANICAL SCHEDULES AND DETAILS
M4
MECHANICAL SCHEDULES AND DETAILS
PLUMBING
P100
PLUMBING SCHEDULES & LEGEND
P101
PLUMBING NOTES & DETAILS
P200
PLUMBING FLOOR PLAN - FIRST FLOOR -
WASTE & RAINWATER PIPING
P201
PLUMBING FLOOR PLAN - SECOND
FLOOR - WASTE & RAINWATER PIPING
P202
PLUMBING FLOOR PLAN - ROOF -
WASTE & RAINWATER PIPING
P300
PLUMBING FLOOR PLAN - ROOF -
WASTE & RAINWATER PIPING
P301
PLUMBING FLOOR PLAN - SECOND
FLOOR - WATER PIPING
P302
PLUMBING FLOOR PLAN - ROOF -
WATER & GAS PIPING
P400
PLUMBING RISER DIAGRAMS - DETAILS -
CALCULATIONS
P401
PLUMBING DETAILS
ELECTRICAL
E001
ELECTRICAL SPECIFICATIONS
E101
ELECTRICAL SITE PLAN
E201
ELECTRICAL PLAN - 1ST FLOOR
E202
ELECTRICAL PLAN - 2ND FLOOR
E301
ONE LINE DIAGRAM, LOAD
CALCULATIONS, SHORT CIRCUT
CALCULATIONS
Grand total: 55
REVISIONS
MARK
DATE
DESCRIPTION
SHEET INDEX
FRONT VIEW
BACKVIEW
RECEVED 29.MAY 25
BA250040 - 1. SUB
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
T.O. CONCRETE HIGH PNT
26' - 8"
T.O. PAVERS & FASCIA
27' - 0"
T.O. WALL
30' - 0"
T.O.CONCRETE @ DRAIN
26' - 6"
2' - 0"
1
A500
8.2
8.2
8.2
8.2
8.2
5.5
5.9
5.4
5.4
5.3
7' - 4"
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
T.O. CONCRETE HIGH PNT
26' - 8"
T.O. PAVERS & FASCIA
27' - 0"
T.O. WALL
30' - 0"
T.O.CONCRETE @ DRAIN
26' - 6"
15' - 4"
1
A600
2' - 8"
7' - 8"
2
A500
9' - 4"
TYP.
8.3
TYP.
8.4
5.4
5.3
5.4
23' - 4"
C
D
D
C
A
A
B
B
B
A
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:13 AM
A400
CH
AK
01-21-2025
EXTERIOR ELEVATIONS
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
KEY NOTES
5.3
NEW METAL FASCIA.
5.4
NEW METAIL RAILING
5.5
HOLLOW METAL DOOR AND FRAME - REFER TO DOOR SCHEDULE
5.9
NEW METAL FASCIA / PLANTER.
8.2
NEW SLIDING GLASS DOOR.
8.3
NEW SLIDER WINDOW.
8.4
NEW FIXED WINDOW.
1/8" = 1'-0"
2 EAST EXTERIOR ELEVATION - COURTYARD
1/8" = 1'-0"
1 NORTH EXTERIOR ELEVATION
REVISIONS
MARK
DATE
DESCRIPTION
2'-0"
6'-1/4"
5'-11 1/2"
House is 36' tall, vary
max. height to 36'
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
T.O. CONCRETE HIGH PNT
26' - 8"
1
T.O. PAVERS & FASCIA
27' - 0"
T.O. WALL
30' - 0"
T.O.CONCRETE @ DRAIN
26' - 6"
23' - 4"
16' - 8"
23' - 4"
1
A600
28' - 8"
9' - 4"
5
2
A500
-6" GARAGE FLOOR LVL
5.2
8.1
5.4
5.3
5.13
E
S.3
S.4
7
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
T.O. CONCRETE HIGH PNT
26' - 8"
D
A
T.O. PAVERS & FASCIA
27' - 0"
T.O. WALL
30' - 0"
T.O.CONCRETE @ DRAIN
26' - 6"
1
A500
15' - 4"
23' - 4"
23' - 4" B.O. CANOPY, TYP.
6
A600
C
D
D
D
A
S.A
S.B
S.C
S.D
S.E
S.G
C.1
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:23 AM
A401
CH
AK
01-21-2025
EXTERIOR ELEVATIONS
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
1/8" = 1'-0"
1 SOUTH EXTERIOR ELEVATION
1/8" = 1'-0"
2 WEST EXTERIOR ELEVATION
KEY NOTES
5.2
EXPOSED STRUCTURAL BEAM, REFER TO STRUCTURAL DRAWINGS.
5.3
NEW METAL FASCIA.
5.4
NEW METAIL RAILING
5.13
EXPOSED CORRUGATED GALVANIZED STEEL DECKING WITH GUTTER.
8.1
NEW GARAGE DOOR.
REVISIONS
MARK
DATE
DESCRIPTION
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
1
6
T.O. PAVERS & FASCIA
27' - 0"
2
3
4
T.O. WALL
30' - 0"
5
2
A500
A600
3
SAFE RM
A600
4
2' - 8"
A600
5
LIVING
32.10
32.11
KITCHEN / LIVING
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
D
A
T.O. PAVERS & FASCIA
27' - 0"
B
C
T.O. WALL
30' - 0"
1
A500
7' - 4"
B.O BEAM
11' - 5 1/4"
B.0 BEAM
11' - 7 1/4"
OFFICE
LIVING
3 CAR GARAGE
MASTER BATH /
CLOSET
MASTER BATH /
CLOSET
BEDROOM 2
KITCHEN / LIVING
HALLWAY
REF TO STRUCTURAL
MASTER BEDROOM
LED TV
LED TV
LED TV
C.1
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:29 AM
A500
CH
AK
01-21-2025
BUILDING SECTIONS
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
KEY NOTES
32.10
OWNER PROVIDED FIREPIT TABLE
32.11
OUTDOOR DECK @ 2'-6 DECK W/ 6" STEPS.
1/4" = 1'-0"
1 E-W BLDG SECTION
1/4"
1' 0"
2 N-S BLDG SECTION
REVISIONS
MARK
DATE
DESCRIPTION
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
RECESSED
2 1/2"
8"
C-CHANNEL
WELDABLE REBAR,
TYP. TO ATTACH TO
C-CHANNEL
ANGLED WALL
3/16" STEEL PLATE
UNDER DECK
16' - 8"
LEVEL 1 CEILING
10' - 0"
T.O. CONCRETE HIGH PNT
26' - 8"
T.O. WALL
30' - 0"
24 X 24
ROOF PAVERS
WEEPS
2' O.C.
WATER
PROOFING
SOIL OVER
GREEN MESH
SCREEN OVER
4 3/8
PEA GRAVEL
T.O. STEEL
26' - 0"
5 1/2" METAL STUD
WITH 5/8" GYP.
LEVEL 2 CEILING
23' - 4"
5
13' - 2" T.O. CONCRETE
W32 BEAM
MASONRY BEYOND
W24 BEAM
WHERE
OCCURS
CLOUD DETAIL WHERE OCCURS
W24 BEAM
WHERE
OCCURS
EXTERIOR MTL SOFFIT PANELS
CLOUD DETAIL WHERE OCCURS
EXTERIOR MTL SOFFIT PANELS
13' - 4" T.O. WOOD FLOORING
10' - 8" B.O. ROOF BEAM
W32 BEAM
MASONRY BEYOND
W12 BEAM
WHERE
OCCURS
RECESSED LIGHITNG
WHERE OCCURS
RECESSED LIGHITNG
WHERE OCCURS
1
23' - 4" T.O. WINDOW HEADER
30' - 0" T.O. MASONRY
12' - 8" T.O. STEEL
W24 BEAM
WHERE OCCURS
W24 BEAM
WHERE OCCURS
20' - 8" WINDOW SILL HIGH
M4
M4
W32
BEAM
FASCIA
2' - 8"
1' - 4"
1' - 4"
8".
8".
CONT. 3/16'
BENT PLATE
2X4 TOP RAIL
CONT.
2X2 POST
13' - 3"
PLANT BY OWNER
DIRT / MULCH
WATERPROOFING
2X2X3/16"
CONT. PLATE
CONC. RECESSED
1" @DRAINAGED GRATE
LANDSCAPE MESH
4" PEA GRAVEL
DRAW LOCATIONS TBD
W12
BEAM
METAL PANEL CEILING
2X4 TOP RAIL
CONT.
2X2 POST
PLANT BY OWNER
DIRT / MULCH
W16
2' X 2' X 2' ROOF PAVERS
ROOF JACKS
COUNTER WHERE PROVIDED
FASCIA
W16 PER
STRUCTURAL
2" METAL PANEL
SOFFIT
CONC. RECESSED
1" @DRAINAGED GRATE
16' - 0".
20"
2X4
STEEL TUBBING
TYP.
3" SPACING
MASONRY WALL
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:31 AM
A600
CH
AK
01-21-2025
WALL SECTIONS & DETAILS
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
KEY NOTES
1/2" = 1'-0"
1 WALL SECTION @ ANGLED WALLS
1/2" = 1'-0"
2 EXTERIOR WALLS AT PLANTERS
1/2" = 1'-0"
3 WALL SECTION EAST
1/2" = 1'-0"
4 WALL SECTION WEST
1" = 1'-0"
5 2ND FLOOR EDGE DTL
1/2" = 1'-0"
6 ROOF PLANTER
1/2" = 1'-0"
7 WINDOW CANOPY - PLAN VIEW
REVISIONS
MARK
DATE
DESCRIPTION
1
Date 1
Revision 1
GENERAL DOOR NOTES
1.
2.
A.
B.
C.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
EGRESS DOORS SHALL BE READILY OPENALBE FROM THE EGRESS SIDE
WITHOUTH THE USE OF A KEY OR SPECIAL KNOWLEDGE.
THE FORCE REQUIRED TO OPEN AN EGRESS DOOR SHALL NOT EXCEED
THE FOLLOWING:
INTERIOR DOORS: 5 POUNDS
EXTERIOR DOORS: 8.5 POUNDS
FIRE DOORS: 15 POUNDS
ROOMS OR SPACES WITH AN OCCUPANT LOAD OF 50 OR MORE IN
GROUP A OR E OCCUPANCY SHALL NOT BE PROVIDED WITH A LATCH
OR LOCK OTHER THAN THE PANIC HARDWARE OF FIRE EXIT
HARDWARE.
REFER TO MECHANICAL PLANS FOR DOORS REQUIRING UNDERCUTS
OR LOUVERS.
FIELD VERIFY WINDOW AND DOOR OPENINGS PRIOR TO
FABRICATION.
PREPARE ALL DOORS AND FRAMES AS REQUIRED TO RECIEVE ALL
SPECIFIED HARDWARE, INCLUDING ELECTRIFIED SYSTEMS WHERE
APPLICABLE.
DOORS AND WINDOWS BETWEEN INTERIOR/EXTERIOR AND
CONDITIONED/UNCONDITIONED SPACES SHALL BE DESIGNED TO
LIMIT AIR LEAKAGE INTO OR FROM THE BUILDING ENVELOPE.
ALL GLAZING IN HAZARDOUS LOCATIONS AS DEFINED BY IBC
SECTION 2406.4, INCLUDING BY NOT LIMITED TO DOORS, SIDELITES,
AND OTHER LOCATIONS INDICATED ON THE DRAWINGS, SHALL BE
SAFETY GLAZING. SAFETY GLAZING SHALL BE PERMANENTLY MARKED
AS SUCH AS REQUIRED BY IBC SECTION 2406.3.
REFER TO SPECIFICATIONS FOR HARDWARE SETS AND ADDITIONAL
DOOR AND FRAME INFORMATION.
CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND PRODUCT
DATA FOR ALL NEW DOORS, FRAMES, AND HARDWARE.
ALL ALUMINUM DOORS AND FRAMES SHALL BE FACTORY FINISHED.
ALL EXTERIOR HOLLOW METAL DOORS SHALL HAVE A MAXIMUM U-
VALUE OF 0.42 WITH POLYSTRENE CORE.
ALL INTERIOR HOLLOW METAL DOORS SHALL HAVE A MINIMUM
HONEYCOMB CORE, U.N.O.
ALL WOOD DOORS SHALL HAVE SOLID CORES.
EDIT AND REMOVE
ANY ITEMS NOT
APPLICABLE
GLAZING DOOR / WINDOW
FRAME NOTES
1.
2.
3.
FIELD VERIFY WINDOW AND DOOR OPENINGS PRIOR TO
FABRICATION.
ALL GLAZING AT EXTERIOR DOORS AND WINDOWS SHALL BE
INSULATED AND COMPLY WITH PROJECT COMCHECK AND
SPECIFICATIONS.
ALL GLASS IN DOORS AND ADJACENT GLAZED OPENINGS AND
WINDOWS SHALL COMPLY WITH IBC SECTION 2406.
EDIT AND REMOVE
ANY ITEMS NOT
APPLICABLE
DOOR SCHEDULE REMARKS
DR1
DOOR TO HAVE BLACK AND WHITE SIGN (PROVIDED BY
MANUFACTURER) THAT READS "THIS DOOR TO REMAIN UNLOCKED
WHEN BUILDING IS OCCUPIED" ADHERED TO FRAME ABOVE DOORS.
EDIT AND REMOVE
ANY ITEMS NOT
APPLICABLE AND ADD
PROJECT SPECIFIC
NOTES AS REQUIRED
ABBREVIATIONS
AL
ALUMINUM
EX
EXISTING
HCMV HOLLOW CORE MASONITE VENEER
HCWV HOLLOW CORE WOOD VENEER
HDW
HARDWARE
HM
HOLLOW METAL
PT
PAINT FINISH
FAC
FACTORY FINISH
MFR
MANUFACTURER
SCHV
SOLID CORE HARDBOARD FACING VENEER
SCWV
SOLID CORE WOOD VENEER
SS
STAINLESS STEEL
GLAZING LEGEND
REFER TO SPECIFICATIONS AND COMCHECK FOR ADDITIONAL
INFORMATION.
G-1
1/4" CLEAR GLASS
G-2
1/4" CLEAR TEMPERED GLASS
G-3
1" INSULATED GLASS
G-4
1" TEMPERED INSULATED GLASS
G-5
1" INSULATED SPANDREL GLASS
EDIT AND REMOVE
ANY ITEMS NOT
APPLICABLE
SEE SCHED.
D001
FULL FLUTED
GLASS
DOOR
D002
FLUSH DOOR
D003
PANELED
DOOR
SEE
SCHEDULE
SEE SCHEDULE
6"
10"
6"
6"
6"
6"
10"
5"
SEE SCHEDULE
SEE SCHEDULE
SEE SCHEDULE
D204
FLUSH PANEL
DOOR
SLIDER
SEE SCHEDULE
SEE SCHEDULE
3 PANEL
MULTI
SLIDING
DOOR
D300
SEE SCHEDULE
SEE SCHEDULE
D400
Multislide
Door
SEE SCHEDULE
2"
SEE
SCHEDULE
2"
2"
F000:HM2
4"
SEE SCHEDULE
2"
SEE
SCHEDULE
2"
F000:HM4
2"
SEE
SCHEDULE
2"
2"
1' - 10"
2"
SEE SCHEDULE
F300
2"
10"
2"
SEE
SCHEDULE
2"
10"
2"
2"
1' - 10"
2"
SEE SCHEDULE
F402
FOHS1
GARAGE
DOOR
FRAME PER
MFR
SEE SCHEDULE
5' - 0"
2' - 8"
3' - 4"
A
1' - 10"
7' - 6"
3' - 4"
SLIDING
WINDOW
FIXED WINDOW
B
2' - 0"
2' - 8"
5' - 4"
C
2ND FLOOR
FIXED WINDOW
2' - 8"
7' - 4"
16' - 0"
D
2ND FLOOR
FIXED WINDOW
5' - 4"
5' - 4"
5' - 4"
E
2' - 8"
7' - 4"
8' - 0"
2ND FLOOR
FIXED WINDOW
4' - 0"
4' - 0"
5' - 4"
10' - 0"
5' - 0"
5' - 0"
F
2ND FLOOR
FIXED WINDOW
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:34 AM
A700
CH
AK
01-21-2025
DOOR SCHEDULE, DOOR TYPES, & DOOR FRAME TYPES
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
DOOR AND FRAME SCHEDULE
DOOR #
DOOR
FRAME
FRAME DETAIL
FIRE
RATING
HDW SET
NOTES
TYPE
SIZE
DOOR FACE
GLASS
TYPE
TYPE
MATERIAL
FINISH
HEAD DETAIL
JAMB DETAIL
SILL DETAIL
WIDTH
HEIGHT
MATERIAL
FINISH
101
10' - 0"
CLOPLAY GARAGE DOOR
102
10' - 0"
CLOPLAY GARAGE DOOR
104
D002
(1) 3' - 0"
7' - 0"
F000 : HM4
18A/A702
18B/A702
18C/A702
STORAGE DOORS
105
D002
(1) 3' - 4"
7' - 8"
F000 : HM4
18A/A702
18B
18C
GARAGE ENTRY DOOR
106
D002
(1) 3' - 4"
7' - 10"
F000 : HM2
10A/A702
10B/A702
10C/A702
PANTRY DOOR
107
D003
(1) 2' - 8"
7' - 8"
F000 : HM4
18A/A702
18B/A702
18C/A702
RESTROOM DOOR
108
D002
(1) 3' - 0"
7' - 0"
F000 : HM4
18A/A702
18B/A702
18C/A702
STORAGE DOORS
109
D002
(1) 5' - 0"
9' - 10"
SF01
PIVOT DOOR
110
D002
(2) 3' - 0"
8' - 6"
SF01
EXTERIOR MAIN ENTRY DOOR
111
10' - 0"
EXTERIOR SLIDING GLASS DOOR
112
10' - 0"
EXTERIOR SLIDING GLASS DOOR
113
D003
(1) 2' - 8"
7' - 10"
F000 : HM2
20A/A702
20B/A702
20C/A702
RESTROOM DOOR
114
D003
(1) 2' - 8"
7' - 0"
F000 : HM2
20A/A702
20B/A702
20C/A702
RESTROOM DOOR
115
D003
(1) 2' - 8"
7' - 10"
F000 : HM2
20A/A702
20B/A702
20C/A702
RESTROOM DOOR
116
D003
(1) 3' - 0"
7' - 10"
F300
20A/A702
20B/A702
20C/A702
RESTROOM DOOR
116A
D204
(1) 2' - 8"
10' - 0"
F000 : HM2
20A/A702
20B/A702
20C/A702
RESTROOM DOOR
117
D003
(1) 2' - 8"
7' - 10"
F000 : HM2
10A/A702
10B/A702
10C/A702
BEDROOM DOOR
117A
D204
(1) 6' - 0"
7' - 10"
F000 : HM2
CLOSET DOOR
118
D003
(1) 2' - 8"
7' - 10"
F000 : HM2
10A/A702
10B/A702
10C/A702
BEDROOM DOOR
118A
D204
(1) 6' - 0"
7' - 10"
F000 : HM2
CLOSET DOOR
119
D003
(1) 2' - 8"
7' - 10"
F000 : HM2
10A/A702
10B/A702
10C/A702
BEDROOM DOOR
119A
D204
(1) 6' - 0"
7' - 10"
F000 : HM2
CLOSET DOOR
120
D002
(1) 3' - 0"
7' - 8"
F000 : HM4
18A/A702
18B/A702
18C/A702
POOL RESTROOM DOOR
121
D002
(1) 3' - 0"
7' - 8"
F000 : HM4
18A/A702
18B/A702
18C/A702
POOL RESTROOM DOOR
201
D002
(1) 5' - 0"
9' - 10"
SF01
PIVOT DOOR
202
D002
(1) 3' - 0"
7' - 10"
F300
18A/A702
18B/A702
18C/A702
EXTERIOR TO DECK
203
D003
(1) 3' - 0"
10' - 0"
F300
18A/A702
18B/A702
18C/A702
RESTROOM DOOR
204
10' - 0"
INTERIOR SLIDING GLASS DOOR
205
D003
(1) 3' - 0"
7' - 10"
F000 : HM2
18A/A702
18B/A702
18C/A702
RESTROOM DOOR
206
10' - 0"
EXTERIOR SLIDING GLASS DOOR
207
D002
(1) 3' - 0"
7' - 10"
F000 : HM2
CONCEALED DOOR
208
10' - 0"
EXTERIOR SLIDING GLASS DOOR
209
10' - 0"
EXTERIOR SLIDING GLASS DOOR
210
D001
(2) 3' - 0"
7' - 10"
F402
10A/A702
10B/A702
10C/A702
BEDROOM DOOR
211
10' - 0"
EXTERIOR SLIDING GLASS DOOR
212
D003
(1) 2' - 8"
7' - 10"
F000 : HM2
20A/A702
20B/A702
20C/A702
RESTROOM DOOR
213
D002
(1) 3' - 0"
7' - 10"
FP00
CONCEALED DOOR
214
D002
(1) 3' - 0"
7' - 10"
F000 : HM2
CONCEALED DOOR
301
D002
(1) 3' - 0"
6' - 8"
F000 : HM2
18A/A702
18B/A702
18C/A702
ROOFTOP DOOR
1/4" = 1'-0"
2 DOOR TYPES
1/4" = 1'-0"
3 DOOR FRAME TYPES
1/4" = 1'-0"
1 WINDOW TYPES.
REVISIONS
MARK
DATE
DESCRIPTION
19' - 4"
10' - 0"
15' - 0"
15' - 0"
12' - 0"
12' - 0"
15' - 0"
15' - 0"
12' - 0"
D400
D400
D300
D300
D400
D300
D300
FOH1S
FOH1S
6"
1/2"
2"
1/2"
THICKNESS
MATCH WALL
1/2"
1/2"
2"
18 GA. DRIP @ EXTERIOR
HEAD FRAMES - TYP.
OCCURS ONLY WHERE
THERE IS NO OVERHANG
JAMB AS INDICATED PER
FRAME ELEVATIONS.
18 GA. DRIP @ EXTERIOR
HEAD FRAMES - TYP.
OCCURS ONLY WHERE
THERE IS NO OVERHANG
STUD WALL FRAME - TYP
SOLID GROUTED
C
HM FRAME IN STUD WALL FRAME
B
HM FRAME IN CMU
A
HM FRAME @ MASONRY HEAD CONDITION
6"
1/2"
4"
18 GA. DRIP @ EXTERIOR
HEAD FRAMES - TYP.
OCCURS ONLY WHERE
THERE IS NO OVERHANG
SOLID GROUTED
JAMB AS INDICATED PER
FRAME ELEVATIONS.
FURRING AS
SCHEDULED
BATT INSULATION AS
SCHEDULED
FURRING AS
SCHEDULED
MASONRY WALL AS
SCHEDULED
MASONRY LINTEL PER
STRUCTURAL DRAWINGS
HORIZONTAL
REINFORCING PER
STRUCTURAL DRAWINGS
SEALANT, CONTINUOUS
ALL SIDES
SOLID GROUTED
HOLLOW METAL FRAME
AS SCHEDULED
DOOR AS SCHEDULED
CONTINUOUS 'J' MOLD
CONTINUOUS
CORNER BEAD
BATT INSULATION
AS SCHEDULED
MASONRY WALL AS
SCHEDULED
HORIZONTAL
REINFORCING PER
STRUCTURAL DRAWINGS
SEALANT CONTINUOUS
ALL SIDES
SOLID GROUTED
HOLLOW METAL FRAME
AS SCHEDULED
DOOR AS SCHEDULED
JAMB ANCHOR
MINIMUM 3 @
MAXIMUM 36" O.C.
ADA THRESHOLD SET IN
DOUBLE BEAD OF
SEALANT
FLOOR FINISH AS
SCHEDULED
EXPANSION JOINT WITH
SEALANT
SEALANT, CONTINUOUS
ALL SIDES
A
HEAD @ MASONRY WALL WITH FURRING
B
JAMB @ MASONRY WALL WITH FURRING
1/2"
AS OCCURS
B.O. LINTEL
1/2"
CONTINUOUS 'J' MOLD
CONTINUOUS
CORNER BEAD
SEALANT, CONTINUOUS
ALL SIDES
C
SILL @ MASONRY WALL WITH FURRING
DOOR AS SCHEDULED
DOOR SHOE WITH
INTEGRAL DRIP
MASONRY WALL AS SCHEDULED
MASONRY LINTEL PER
STRUCTURAL DRAWINGS
DOOR AS SCHEDULED
SEALANT, CONTINUOUS ALL
SIDES
SOLID GROUTED HOLLOW
METAL FRAME AS SCHEDULED
HORIZONTAL REINFORCING
PER STRUCTURAL DRAWINGS
JAMB ANCHOR MINIMUM 3 @
MAXIMUM 36" O.C.
HORIZONTAL REINFORCING
PER STRUCTURAL DRAWINGS
DOOR AS SCHEDULED
DOOR SHOE WITH INTEGRAL DRIP
FLOOR FINISH AS
SCHEDULED
ADA THRESHOLD SET
IN DOUBLE BEAD OF
SEALANT
EXPANSION JOINT WITH SEALANT
1/2"
A
HEAD @ MASONRY WALL
B
JAMB @ MASONRY WALL
MASONRY WALL AS SCHEDULED
DOOR AS SCHEDULED
SEALANT, CONTINUOUS ALL
SIDES
SOLID GROUTED HOLLOW
METAL FRAME AS SCHEDULED
1/2"
C
SILL @ MASONRY WALL
BATT INSULATION AS
SCHEDULED
BOX HEADER PER
STANDARD FRAMING
DETAILS
5/8" TYPE 'X' GYPSUM
BOARD
HOLLOW METAL FRAME
AS SCHEDULED
DOOR AS SCHEDULED
DOOR AS SCHEDULED
DOOR FRAME BEYOND
AS SCHEDULED
#
SEE PLAN
#
SEE
PLAN
FLOOR FINISH AS
SCHEDULED, TRANSITION
@ CENTER OF DOOR
PANELS, TYP.
Z-FRAME ANCHOR
A
HEAD @ FRAMED WALL
B
JAMB @ FRAMED WALL
C
SILL @ FRAMED WALL
BATT INSULATION AS
SCHEDULED
DOUBLE STUD FRAMING
5/8" TYPE 'X' GYPSUM
BOARD
HOLLOW METAL FRAME
AS SCHEDULED
DOOR AS SCHEDULED
1/2" MIN.
1/2" MIN.
1/2" MIN.
1/2" MIN.
SEALANT, CONTINUOUS
ALL SIDES
SEALANT CONTINUOUS
ALL SIDES
MUD BED @
CONCRETE
BLOCK OUT
1 1/2"
DOOR AS SCHEDULED
STONE THRESHOLD
W/ EASED EDGES
FLOOR FINISH AS
SCHEDULED
DOOR FRAME BEYOND
AS SCHEDULED
1/2"
1"
RESTROOM SIDE
CORRIDOR SIDE
BATT INSULATION AS
SCHEDULED
BOX HEADER PER
STANDARD FRAMING
DETAILS
5/8" TYPE 'X' GYPSUM
BOARD
HOLLOW METAL FRAME
AS SCHEDULED
DOOR AS SCHEDULED
#
SEE PLAN
#
SEE
PLAN
Z-FRAME ANCHOR
A
HEAD @ FRAMED WALL
BATT INSULATION AS
SCHEDULED
DOUBLE STUD FRAMING
1/2" WATER RESISTANT
TYPE 'X' GYPSUM BOARD
HOLLOW METAL FRAME
AS SCHEDULED
DOOR AS SCHEDULED
1/2" MIN.
1/2" MIN.
1/2" MIN.
1/2" MIN.
SEALANT, CONTINUOUS
ALL SIDES
C
SILL @ FRAMED WALL
B
JAMB @ FRAMED WALL
CEMENTITIOUS BACKER
BOARD, SEE INTERIOR
ELEVATIONS
5/8" TYPE 'X'
GYPSUM BOARD
CERAMIC WALL TILE PER
SPECIFICATIONS &
INTERIOR ELEVATIONS
SEALANT,
CONTINIUOUS
ALL SIDES
HEAD
JAMB
JAMB
A
B
C
OUTSIDE
OUTSIDE
OUTSIDE
INSIDE
INSIDE
INSIDE
CONT. SEALANT
AND BACKER ROD
ALUMINUM DOOR
PER SPECIFICATIONS
WALL AS
PER PLANS
ALUMINUM FRAME
PROFILE PER
SPECIFICATIONS
CONT. SEALANT
AND BACKER ROD
ALUMINUM FRAME
PROFILE PER
SPECIFICATIONS
GASKET
GLAZING PER
SPECIFICATIONS
WALL PER PLANS
BULB GASKET
GASKET
GLAZING PER
SPECIFICATIONS
ALUMINUM FRAME
PROFILE PER
SPECIFICATIONS
WALL PER PLANS
VERTICAL MULLION
SILL
SILL
SILL
G
H
K
J
THRESHOLD AS OCCURS
ALUMINUM DOOR
AS SCHEDULED
ALUMINUM FRAME
PROFILE PER
SPECIFICATIONS
CONT. SEALANT
AND BACKER ROD
GLAZING PER
SPECIFICATIONS
SETTING BLOCK
GASKETS
OUTSIDE
INSIDE
OUTSIDE
INSIDE
SEALANT
GLAZING PER SPECIFICATIONS
GLAZING PER
SPECIFICATIONS
ALUMINUM FRAME
PROFILE PER
SPECIFICATIONS
OUTSIDE
INSIDE
SETTING BLOCK
ALUMINUM FRAME
PROFILE PER
SPECIFICATIONS
CONT. SEALANT AND
BACKER ROD
GLAZING PER
SPECIFICATIONS
SETTING BLOCK
GASKETS
OUTSIDE
INSIDE
WALL PER PLANS
1/2"
1/2"
1/2"
2"
1/2"
JAMB
TRANSOM
HORIZONTAL MULLION
D
E
F
OUTSIDE
OUTSIDE
OUTSIDE
INSIDE
INSIDE
INSIDE
SETTING BLOCK
GLAZING PER
SPECIFICATIONS
GLAZING PER
SPECIFICATIONS
GASKETS
CLIP
ALUMINUM FRAME
PROFILE PER
SPECIFICATIONS
BULB GASKET
STOREFRONT DOOR
AS SPECIFIED
SETTING BLOCK
ALUMINUM FRAME
PROFILE PER
SPECIFICATIONS
GLAZING PER
SPECIFICATIONS
ALUMINUM DOOR PER
SPECIFICATIONS
GASKET
GLAZING PER
SPECIFICATIONS
ALUMINUM FRAME
PROFILE PER
SPECFICATIONS
INSIDE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
OUTSIDE
INSIDE
OUTSIDE
BOT. OF LINTEL
AS OCCURS
SOLID GROUTED FRAME
TYP. SEE DETAIL
SOLID GROUTED FRAME
TYP. SEE DETAIL
SOLID GROUTED FRAME
TYP. SEE DETAIL
MASONRY WALL AS
SCHEDULED
MASONRY WALL AS
SCHEDULED
MASONRY LINTEL AS
SCHEDULED
FURRING AS
SCHEDULED
FURRING AS
SCHEDULED
FURRING AS
SCHEDULED
JAMB ANCHOR
(3) - MAX 36" O.C.
CONTINUOUS
CORNER BEAD
CONTINUOUS
CORNER BEAD
CONTINUOUS
'J' MOLD
CONTINUOUS
'J' MOLD
CONTINUOUS
'J' MOLD
SEALANT, CONTINUOUS
EACH SIDE
SEALANT,
CONTINUOUS
EACH SIDE
SEALANT,
CONTINUOUS
EACH SIDE
SEALANT,
CONTINUOUS
EACH SIDE
INSULATED GLAZING
SYSTEM
5/8"" x 5/8" CONTINUOUS
GLASS STOP - TYPICAL
5/8"" x 5/8" CONTINUOUS
GLASS STOP - TYPICAL
5/8"" x 5/8" CONTINUOUS
GLASS STOP - TYPICAL
5/8"" x 5/8" CONTINUOUS
GLASS STOP - TYPICAL
INSULATED GLAZING
SYSTEM
INSULATED GLAZING
SYSTEM
INSULATED GLAZING
SYSTEM
SOLID GROUTED FRAME
TYP. SEE DETAIL
CONCRETE SLAB
WELDED BOX
HEADER, SEE
STRUCTURAL
WELDED STUD
JAMB
1/4" GLAZING, TYP.
1/4" GLAZING, TYP.
1/4" GLAZING, TYP.
1/4" GLAZING, TYP.
WELDED STEEL FLASHING
AT HEAD AT EXTERIOR
DOORS
1/2"
1/2"
1/2"
A
WINDOW HEAD
B
WINDOW JAMB
C
WINDOW SILL
D
WINDOW SILL
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:37 AM
A702
CH
AK
01-21-2025
DOOR AND WINDOW DETAILS
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
3" = 1'-0"
7 DOOR FRAME PROFILE, TYP.
1 1/2" = 1'-0"
17 DOOR FRAME @ FURRED CMU
1 1/2" = 1'-0"
18 HM DOOR FRAME @ MASONRY
1 1/2" = 1'-0"
10 FRAME @ INTERIOR WALL
1 1/2" = 1'-0"
20 FRAME @ RESTROOM DOOR
3" = 1'-0"
16 ALUMINUM FRAMING
1 1/2" = 1'-0"
19 HM WINDOW FRAME @ MASONRY
REVISIONS
MARK
DATE
DESCRIPTION
UP
4
A800
M1
M1
5
A800
17' - 0"
8' - 3 1/8"
8"
7 5/8"
(7) 11" TREADS
6' - 5"
5' - 0"
(12)11" TREADS
11' - 0"
3
A800.2
4
A800.2
6
A800
4
A800
5
A800
6' - 0"
6"
21' - 7 1/8"
7 5/8"
(12) 11" TREADS
11' - 0"
3
A800.2
4
A800.2
8' - 3"
301
6
A800
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
D
T.O. PAVERS & FASCIA
27' - 0"
T.O. WALL
30' - 0"
STAIR LANDING 1
8' - 3 1/8"
STAIR LANDING 2
21' - 7 1/8"
11 x 7 5/8"
STAIR TREADS
11 x 7 5/8"
STAIR TREADS
11 x 7 5/8"
STAIR TREADS
A800
7
11"
7 5/8"
28' - 6"
7 1/2"
11' - 0"
6
A800
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
D
T.O. PAVERS & FASCIA
27' - 0"
T.O. WALL
30' - 0"
STAIR LANDING 1
8' - 3 1/8"
STAIR LANDING 2
21' - 7 1/8"
11 X 7 1/4"
CONCRETE STAIRS
LEVEL 2 CEILING
23' - 4"
7' - 7 1/8"
7 1/4"
5' - 4 7/8"
6
A800
STEEL STINGER PER
STAIR MANUFACTURE
WOOD TREAD
3"
11"
CURTAIN WALL
DECORATIVE METAL TRIM
8" X 8" X8" BLOCK
ROOF
ROOF
FIRST FLOOR
0"
SECOND FLOOR
13' - 4"
6
4
T.O. WALL
30' - 0"
4
A800
STAIR LANDING 1
8' - 3 1/8"
STAIR LANDING 2
21' - 7 1/8"
5
A800
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:48 AM
A800
CH
AK
01-21-2025
VERTICAL CIRUCLATION - STAIRS
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
1/4" = 1'-0"
1 STAIR - FIRST TO SECOND FLOOR
1/4" = 1'-0"
2 STAIR - SECOND FLOOR TO ROOF
1/4" = 1'-0"
4 STAIR - VERTICAL SECTION
1/4" = 1'-0"
5 STAIR - VERTICAL SECTION1
1 1/2" = 1'-0"
7 TREAD PROFILE
1 1/2" = 1'-0"
8 BLOCK AT CURTAIN WALL INTERSECTION
REVISIONS
MARK
DATE
DESCRIPTION
1/4" = 1'-0"
3 LANDING TO ROOF
1/4" = 1'-0"
6 STAIR - VERTICAL CROSS SECTION
7' - 9"
6' - 6"
3' - 0"
4' - 7"
5' - 7 1/2"
7' - 7"
3' - 8"
7' - 10 1/2"
5' - 7 1/2"
7' - 7"
10' - 3"
10' - 3"
7' - 1"
CLEAR
3'-0".
RR
7' - 5"
10"
05 / A801
10 / A801
09 / A801
7' - 3 1/2"
CLEAR
5'-0".
6' - 0"
1' - 5"
7' - 1 1/4"
R 5' - 6"
R 5' - 6"
11 / A801
BATHROOM 2
HALLWAY
1' - 3"
1' - 3"
1' - 3"
1' - 3"
115
114
113
116A
116
OPEN TO
BEYOND
SOFFIT 10' - 0"
B.O DECK 12' - 8"
OPEN TO BEYOND
CEILING 10' - 0"
4"
KNEE
SPACE
CEILING 10' - 0"
MIRROR
MIRROR
LED
TV
LED
TV
STOVE
SOFFIT 10' - 0"
RANGE HOOD
B.O DECK 12' - 8"
POT
FILLER
REFRIGERATOR
WITHIN
BUILT IN
CABNITRY
LED
TV
LED
TV
KITCHEN ISLAND
(KNEE SPACE)
EXPOSED STRUCTURAL BEAMS
SOFFIT 10' - 0"
B.O DECK 12' - 8"
OVEN
OVEN
CEILING 10' - 0"
MIRROR
CEILING 10' - 0"
105
GARAGE FLOOR -6"
HOUSE F.F. 0"
22.1
22.2
22.3
9.2
5.2
B.O DECK 12' - 8"
111
112
2 WAY
INDOOR / OUTDOOR
FIRE PLACE
SOFFIT 10' - 0"
EXPOSED STRUCTRAL BEAMS
B.O DECK 12' - 8"
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:53 AM
A801
CH
AK
01-21-2025
1ST FLOOR ENLARGED PLANS & ELEVATIONS
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
1/4" = 1'-0"
06 ENLARGED HALLWAY AREA - AND RESTROOMS
1/4" = 1'-0"
05 WETBAR / WINE RACK AREA
1/4" = 1'-0"
10 HALLWAY ELEVATION
1/4" = 1'-0"
09 BATHROOM 2 - WEST
1/4" = 1'-0"
01 KITCHEN ELEVATION -1
1/4" = 1'-0"
02 KITCHEN ELEVATION 2
1/4" = 1'-0"
03 KITCHEN ELEVATION -3
1/4" = 1'-0"
04 KITHCEN ELEVATION - 4
1/4" = 1'-0"
11 BATH 1 - EAST
1/4" = 1'-0"
08 GARAGE - NORTH
1/4" = 1'-0"
07 LIVING ROOM - EAST
REVISIONS
MARK
DATE
DESCRIPTION
STACKING W/D
1
A
C
MASTER BEDROOM
MASTER BATH /
CLOSET
210
212
2 / A802
1' - 1"
3 / A802
5' - 9"
8' - 10 1/2"
5' - 2 1/2"
4' - 1"
2' - 9"
6' - 0"
2' - 10"
8' - 0"
5' - 5"
10' - 10"
5' - 6"
213
6' - 0".
3' - 4"
4 / A802
5 / A802
CUSTOM BUILT CLOSETS
CUSTOM
BUILT CLOSETS
SOFFIT CEILING @10FT
8"
5' - 0 1/2"
ALIGN
ALIGN
1' - 3"
A1
A2
A2
A1
A1
A1
A1
CLEAR
4' - 0".
A1
D
D
D
211
-13" NICHE
+0
FIRE PLACE
CEILING 10' - 0"
OPEN TO
BEYOND
MIRROR
KNEE
SPACE
CEILING 10' - 0"
KNEE
SPACE
+24" BATH TUB
D
C
MIRROR
4"
CEILING 10' - 0"
4' - 0"
1' - 8"
-4" SHOWER
NICHE
OPEN
TO
BEYOND
OPEN
TO
BEYOND
CEILING 10' - 0"
SHOWER GLASS
BENCH
3' - 0"
CEILING 10' - 0"
LED TV
RANGE HOOD
DOUBLE OVEN
COOKTOP
REFRIDGERATOR
POT
FILLER
BARTOP
COUNTER
KNEE SPACE
LED TV
RANGE HOOD
CEILING 10' - 0"
201
208
209
2 WAY
INDOOR / OUTDOOR
FIRE PLACE
EXPOSED STRUCTRAL BEAMS
SHEET:
DATE:
JOB No:
REVIEWED BY:
DRAWN BY:
Autodesk Docs://22045 - Lance Little Residence/22045 - LANCE LITTLE RESIDENCE.rvt
1/21/2025 11:53:56 AM
A802
Author
Checker
01-21-2025
2ND FLOOR ENLARGED PLANS & ELEVATIONS
LITTLE RESIDENCE
LANCE LITTLE
25847 N. 19TH AVENUE PHOENIX, ARIZONA 85085
PERMIT SUBMISSION
1/4" = 1'-0"
1 ENLARGED - MASTER BEDROOM / BATH
1/4" = 1'-0"
2
MASTER BEDROOM
ENTERTAINMENT NICHE
1/4" = 1'-0"
3 MASTER BATH - WEST
1/4" = 1'-0"
4 MASTER BATH - NORTH
1/4" = 1'-0"
5 MASTER BATH - SOUTH
REVISIONS
MARK
DATE
DESCRIPTION
1/4" = 1'-0"
6 2ND FLOOR KITCHEN
1/4" = 1'-0"
7 2ND FLOOR KITCHEN -2
1/4" = 1'-0"
8 2ND FLOOR - LIVING ROOM EAST