02. Z2023032 Staff Report
Extracted text (via pymupdf)
79762 characters
Z2023032
Page 1 of 6
Report to the Planning and Zoning Commission
Prepared by the Maricopa County Planning and Development Department
Case:
Z2023032 - AZL01741 – Leister Farm
Hearing Date:
June 22, 2023
Supervisor District:
4
Applicant:
Michael Hannah, Smartlink LLC.
Owner:
Leister Agrienterprises LLC.
Request:
Special Use Permit (SUP) for a wireless communication facility in the Rural-
43 zoning district
Site Location:
Generally located west of the SWC of Lower Buckeye Rd. & Perryville Rd. in
the Buckeye area
Site Size:
Approx. 1,000 Sq. Ft.
Density:
N/A
County Island:
Yes (City of Buckeye)
County Plan:
Rural Development Area (0-1 d.u./ac)
Municipal Plan:
Buckeye – Neighborhoods (1+ d.u./ac)
Municipal Comments:
Buckeye – letter of support
Support/Opposition:
None known
Recommendation:
Approve with conditions
Z2023032
Page 2 of 6
Project Summary:
1.
This special use permit (SUP) request is to establish a new wireless communications facility
(WCF) on approximately 1,000 square feet of land located on APN 502-48-002K located west of
the southwest corner of Lower Buckeye & Perryville roads in the Buckeye area. The wireless
facility will feature an 80-foot monopole which will be stealth designed as a pine tree. The request
includes an 8-foot solid wall compound surrounding the wireless pole and communication
facilities. The site is located on an active agriculture operation and has been provided both access
and utility easements to the site by the landowner. The tower is currently slated for a single carrier
though has available space for future co-location. The tower is set back 330-feet from the
southern property boundary and meets all other setback requirements.
2.
The application was submitted on March 16, 2023. A technical advisory committee (TAC) meeting
on the application occurred on April 18, 2023 to discuss technical aspects and requirements with
the applicant. A revision to the application was submitted May 23, 2023.
3.
The SUP requirement was triggered due to the diameter of the tower structure and antenna array:
Rural-43 Zoning & Surrounding Districts
Regulation
Rural-43 Zoning Standard
Proposed SUP Standards
Maximum diameter of antenna
arrays
8-feet
14-feet
Tower maximum diameter
30-Inches (2.5 Feet)
36-Inches (3 Feet)
Z2023032
Page 3 of 6
SUP Area Site Plan
Overall Site Plan
Z2023032
Page 4 of 6
Existing On-Site and Adjacent Zoning / Land Use:
On Site:
Rural-43 / agriculture
North:
Medium Residential (City of Buckeye Jurisdiction) / agriculture
South:
Medium Residential (City of Buckeye Jurisdiction) / agriculture
East:
Rural-43 / agriculture
West:
Medium Residential (City of Buckeye Jurisdiction) / agriculture
Utilities and Services:
4.
Water:
N/A
Wastewater:
N/A
School Districts:
Liberty Elementary School District
Buckeye Union High School District
Fire:
Buckeye Valley Rural Fire District
Police:
Maricopa County Sheriff’s Office
Right-of-Way:
5.
The following table includes existing and proposed half-width right-of-way and the future
classification based upon the Maricopa County Department of Transportation (MCDOT) Major
Streets and Routes Plan.
Street Name
Half-width Existing R/W
Half-width Proposed R/W
Future Classification
Lower Buckeye Rd.
33-feet
65-feet
Principal Arterial
Adopted Plan:
6.
City of Buckeye General Plan: The City of Buckeye’s General Plan, updated in 2022, designates
this site as ‘Neighborhoods’ which allows land densities over 1 du/ac.
Public Participation Summary:
7.
The applicant complied with the Maricopa County Citizen Review Process with the required
posting of the site and notification within 300’ of the subject parcels and to interested parties. To
date, staff has not received any public support or opposition.
8.
The City of Buckeye provided comment and stated, “The City of Buckeye has no concerns with
the request for a proposed 80’ tall cell tower on the subject parcel.” The city did note they would
prefer if the pole utilized a palm tree screening scheme as opposed to the pine tree screening.
The applicant discussed the palm tree screening options with the landowner, who ultimately
preferred the pine tree screening for the use.
Staff Analysis:
9.
The location is ideal for a wireless communications facility as it is amongst an agricultural use in
the middle of a field. The location does not impact any current development and is situated far
enough away from parcel boundaries that when the City of Buckeye does expand into the
neighboring areas there will not be any impact to future area developments. The landowner has
provided access easements for the wireless companies to access the site without interfering with
Z2023032
Page 5 of 6
agriculture activities. Staff recognizes and appreciates the effort to utilize stealth measures to
hide the pole.
Recommendation:
10.
Staff recommends the Commission adopt a motion recommending that the Board of Supervisors
approve Z2023032 subject to the following conditions ‘a’ – ‘h’:
a.
Development of the site shall be in substantial conformance with the site plan entitled
“AZL01741 Leister Farms“, consisting of 15 full-size sheets, dated May 23, 2023, except
as modified by the following conditions. Staff may determine slight refinements to remain
in substantial conformance with the approved site plan. Minor and major amendments to
the site plan will be determined in accordance with Chapter 3 of the Maricopa County
Zoning Ordinance.
b.
Development of the site shall be in substantial conformance with the Narrative Report
entitled “Special Use Permit Application Addendum 4: Project Narrative for Z2023032”,
consisting of 2 pages, dated May 8, 2023, and stamped received May 21, 2023, except as
modified by the following conditions.
c.
The wireless communication tower shall retain the stealth properties as originally
designed. Any damaged or missing fronds or branches shall be replaced within 60 days
of such damage occurring.
d.
This special use permit is valid for a period of twenty-five (25) years and shall expire on
July 26, 2048, or upon termination of the use for a period of 90 or more consecutive days,
whichever occurs first. All site improvements associated with the special use permit shall
be removed within 90 days of such expiration or termination of use.
e.
The following SUP standards shall apply:
1. Maximum diameter of antenna arrays: 14-feet
2. Tower maximum diameter: 36-inches
f.
The following engineering conditions shall apply:
1.
Lower Buckeye Road is classified as a principal arterial, and 65-feet preservation
is required from the section line.
2.
Driveway access to County roads must be paved and will require a permit from
MCDOT issued concurrent with building permit(s) required for site development.
OR; provide documentation that a paved driveway access is not required per
MCDOT at the time of application for a building permit.
3.
The applicant must execute a Wireless Agreement with MCDOT for all equipment,
conduit, F/O and other work that will be within the MCDOT ROW. This agreement
must be coordinated with Ms. Kelly Roy, MCDOT Utility Branch Coordination
Manager, 602-506-8603 or Kelly.Roy@maricopa.gov. OR; provide documentation
that a wireless agreement is not required at the time of application for a building
permit.
Z2023032
Page 6 of 6
4.
All development and engineering design shall be in conformance with Section
1205 of the Maricopa County Zoning Ordinance; Drainage Policies and Standards;
Floodplain Regulations for Maricopa County; MCDOT Roadway Design Manual;
and current engineering policies, standards and best practices at the time of
application for construction.
5.
Engineering review of planning and/or zoning cases is for conceptual design only
and does not represent final design approval nor shall it entitle applicants to future
designs that are not in conformance with Section 1205 of the Maricopa County
Zoning Ordinance and Drainage Policies and Standards; Floodplain Regulations for
Maricopa County; and the MCDOT Roadway Design Manual.
g.
Noncompliance with any Maricopa County Regulation shall be grounds for initiating a
revocation of this [Special Use Permit or Zone Change] as set forth in the Maricopa County
Zoning Ordinance.
h.
The granting of this change in use of the property has been at the request of the applicant,
with the consent of the landowner. The granting of this approval allows the property to
enjoy uses in excess of those permitted by the zoning existing on the date of application,
subject to conditions. In the event of the failure to comply with any condition, and at the
time of expiration of the special use permit, the property shall revert to the zoning that
existed on the date of application. It is, therefore, stipulated and agreed that either
revocation due to the failure to comply with any conditions, or the expiration of the special
use permit, does not reduce any rights that existed on the date of application to use, divide,
sell or possess the property and that there would be no diminution in value of the property
from the value it held on the date of application due to such revocation or expiration of
the special use permit. The special use permit enhances the value of the property above
its value as of the date the special use permit is granted and reverting to the prior zoning
results in the same value of the property as if the special use permit had never been
granted.
Presented by:
Andrew Lorentzen, Planner
Reviewed by:
Matthew Holm, AICP, Planning Supervisor
Attachments:
Case Map (1 page)
Site Plan (reduced 8.5”x11”, 15 pages)
Narrative Report/Ex. Summary (2 pages)
MCDOT comments (2 pages)
City of Buckeye comment (2 pages)
/
Maricopa County Planning & Development - Phoenix, AZ
5
Gross Acres: 1 approx.
Generated June 6, 2023 20:43 PM
Z2023032
Application Name:
Legal Description
AZL01741 – Leister Farm EDR
Applicant
Case Address
,
Michael Hanna for SMARTLINK, LLC
19029 W LOWER BUCKEYE Rd
Applicant Phone/Email
Parcel Primary:502-48-002K
951.319.1341
michael.hanna@smartlinkgroup.com
BUCKEYE AZ 85326
Map scale 1:3,258
Supervisor District No.
AT&T IS LOOKING TO EXPAND COVERAGE IN THE BUCKEYE AREA BY LOCATING A PROPOSED
WIRELESS COMMUNICATIONS FACILITY AT 19029 W LOWER BUCKEYE RD, BUCKEYE AZ 85326, AS
5.3585 in
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
T-1
TITLE
SHEET
R
Dial 8-1-1 or 1-800-STAKE-IT (782-5348)
In Maricopa County: (602) 263-1100
Call at least two full working days
before you begin excavation.
Arizona Blue Stake, Inc.
ARIZONA
BUILDING CODE:
INTERNATIONAL BUILDING CODE 2012
ELECTRICAL CODE:
NATIONAL ELECTRICAL CODE 2011
LIGHTNING PROTECTION CODE: NFPA 780 - 2000, LIGHTNING PROTECTION CODE
SUBCONTRACTOR'S WORK SHALL COMPLY WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL
CODES AS ADOPTED BY THE LOCAL AUTHORITY HAVING JURISDICTION (AHJ) FOR THE LOCATION.
THE EDITION OF THE AHJ ADOPTED CODES AND STANDARDS IN EFFECT ON THE DATE OF
CONTRACT AWARD SHALL GOVERN THE DESIGN.
FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND STANDARDS REGARDING
MATERIAL, METHODS OF CONSTRUCTION, OR OTHER REQUIREMENTS, THE MOST RESTRICTIVE
REQUIREMENT SHALL GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL REQUIREMENT
AND A SPECIFIC REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL GOVERN.
PTN: 3901A14EXT, 3901A14EW1, 3901A0YBKT,
CLIENT REPRESENTATIVE
PROJECT OWNER
COMPANY:
AT&T
ADDRESS:
1355 WEST UNIVERSITY DRIVE
CITY, STATE, ZIP:
MESA, AZ 85201-5419
COMPANY:
SMARTLINK, GROUP
ADDRESS:
8767 E. VIA DE VENTURA, SUITE 200
CITY, STATE, ZIP:
SCOTTSDALE, AZ 85258
CONTACT:
JOHN TISHUCK
PHONE:
(480) 262-6316
E-MAIL:
JOHN.TISHUCK@SMARTLINKGROUP.COM
PROFESSIONAL OF RECORD
COMPANY:
SMARTLINK, GROUP
ADDRESS:
8767 E. VIA DE VENTURA, SUITE 200
CITY, STATE, ZIP:
SCOTTSDALE, AZ 85258
CONTACT:
RACHAEL CARSON
PHONE:
(602) 793-8101
E-MAIL:
RACHAEL.CARSON@SMARTLINKGROUP.COM
SITE INFORMATION
PROJECT TEAM
VICINITY MAP
DRIVING DIRECTIONS
FROM AT&T OFFICE: 1355 WEST UNIVERSITY DRIVE, MESA, AZ 85201-5419:
CODE COMPLIANCE
NOT TO SCALE
CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB
SITE AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY
DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.
THE FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. A TECHNICIAN WILL VISIT THE SITE
AS REQUIRED FOR ROUTINE MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT
DISTURBANCE OR EFFECT ON DRAINAGE; NO SANITARY SEWER SERVICE, POTABLE WATER, OR
TRASH DISPOSAL IS REQUIRED AND NO COMMERCIAL SIGNAGE IS PROPOSED.
PDF DRAWING ISSUED AS 24X36 SHALL BE PRINTED 50% SCALE CENTERED ON PAGE FOR 11X17
PRINTS. PDF DRAWINGS ISSUED 11X17 SHALL BE PRINTED 100% CENTERED.
DO NOT SCALE DRAWINGS
GENERAL NOTES
PROJECT DESCRIPTION
AT&T (RF):
DATE:
AT&T (CONST.):
DATE:
AT&T (SAM):
DATE:
LANDLORD:
DATE:
LANDLORD:
DATE:
APPROVALS
N
SHEET
DESCRIPTION
PROPERTY OWNER
TOWER OWNER
COMPANY:
LEISTER AGRIENTERPRISES, LLC.
LEISTER DWIGHT B JR / RAYANNE L TR
ADDRESS:
19027 E LOWER BUCKEYE RD
CITY, STATE, ZIP:
BUCKEYE, AZ 85326
COMPANY:
AT&T
ADDRESS:
1355 WEST UNIVERSITY DRIVE
CITY, STATE, ZIP:
MESA, AZ 85201-5419
LATITUDE:
33° 25' 06.630" N (33.4185083) N (NAD 83)
LONGITUDE:
112° 28' 07.319" W (112.4686997) W (NAD 83)
LAT\LONG TYPE:
NAD 83
GROUND ELEVATION:
942.9' AMSL (NAVD 88)
APN #:
502-48-002K
AREA OF CONSTRUCTION:
PROPOSED 30'x30' LEASE AREA
ZONING/JURISDICTION:
MARICOPA COUNTY
CURRENT ZONING:
RU-43
PROPOSED USE:
UNMANNED TELECOMMUNICATIONS FACILITY
COUNTY:
MARICOPA COUNTY
HANDICAP REQUIREMENTS:
FACILITY IS UNMANNED AND NOT FOR HUMAN
HABITATION. HANDICAPPED ACCESS NOT REQUIRED.
TRANSPORT SOLUTION: (FIBER) CENTURYLINK
COMMERCIAL POWER PROVIDER: SRP
COMMERCIAL POWER INSPECTING AUTHORITY: SRP
TURN LEFT ONTO W UNIVERSITY DR, TURN LEFT ONTO S PRICE RD, TAKE THE RAMP ONTO AZ-101 LOOP S, MERGE ONTO AZ-101 LOOP S, TAKE EXIT 61C FOR ARIZONA 202 LOOP E, MERGE ONTO
AZ-202/AZ-202 LOOP E, TAKE EXIT 44 FOR GILBERT RD, TURN RIGHT ONTO S GILBERT RD, SITE WILL BE ON THE RIGHT.
FA: 15458424 USID: 319680
THIS PROJECT WILL BE COMPRISED OF:
NEW AT&T ANTENNA ARRAY:
·
INSTALL (3) NEW MC-K6M-B SERIES ANTENNA SECTOR MOUNTS ON NEW MONOPINE
·
INSTALL (9) NEW ANTENNAS, (3) PER SECTOR, (3) SECTORS
·
INSTALL (6) NEW RRH'S, (1) AIRSCALE TRI RRH 4T4R B12/14/29 370W AHLBBA PER SECTOR, (1)
AIRSCALE DUAL RRH 4T4R B25/66 320W AHFII PER SECTOR, (3) SECTORS
·
INSTALL (2) NEW DC-9 SURGE SUPRESSORS
·
INSTALL (6) NEW DC TRUNK CABLES (#6 AWG)
·
INSTALL (2) NEW FIBER TRUNKS (24 PR)
NEW AT&T EQUIPMENT AREA:
·
INSTALL (1) NEW UL LISTED 3-BAY WALK UP CABINET (WUC) ON NEW GRAVITY MOUNT PLATFORM,
EMI / [NEQ.20579]
·
INSTALL NEW SPD CABINET ON NEW UNISTRUT RAIL
·
INSTALL NEW CABLE BRIDGE
·
· INSTALL NEW DIESEL NEQ.20574 POLAR POWER, INC., 8220-100-D-20-03-V,,,,48 VDC; 20KW; DC
GENERATOR HORIZONTAL ENCLOSURE WITH 54 GALLON FUEL TANK WITH OPV ON NEW GALV.
GRAVITY MOUNT PLATFORM
·
INSTALL 2.5"Ø CONDUIT FROM LEC MEET POINT TO NEW WUC
·
INSTALL (1) NEW GPS ANTENNA TO CABLE BRIDGE
PERMANENT STANDBY GENERATOR
MINIMUM REQUIRED BACKUP TIME IS 2.0 HOURS.
BATTERY CHECK:
·
SITE WILL HAVE (2) STRINGS (8 CELLS) OF NEW ENERSYS 190 AMP-HOUR BATTEREIS IN BOTTOM
SECTION OF NEW DC POWER SYSTEM, CONFIGURED AS (4) CELLS PER STRING @ -48 VDC NOMINAL.
TWO STRINGS WILL ACHIEVE 2 HRS OF BATTERY RESERVE CAPACITY.
HVAC UNITS
·
NO HVAC - WUC HAS ONE DC-POWERED HEX ("HEAT EXCHANGER") PER BAY
DC POWER PLANT, RECTIFIERS & CONVERTERS:
·
NEW WUC CABINET WITH (1) VERTIV STD -48VDC OUTDOOR NETSURE 5100 SYSTEM 525A EQUIPPED
WITH (2) EA. BATTERY STRINGS
·
INSTALL (11) EA. NEW VERTIV HE 2KW -48VDC RECTIFIERS [NEQ.15930] TO SATISFY N+1 REDUNDANCY
·
INSTALL (12) EA. NEW VERTIV HE 2KW -58VDC RECTIFIERS [NEQ.15930] TO SATISFY N+1 REDUNDANCY
DC CIRCUIT BREAKERS (SEE SHEET E-2 FOR DC BREAKER PANEL SCHEDULE):
(1)
EA. 10 AMP
(2)
EA. 20 AMP
(7)
EA. 40 AMP
(10) EA. 50 AMP
(1)
EA. 100 AMP
RFDS DATA
DESIGN PACKAGE BASED ON RF DATA SHEET
RFDS NAME: AZL01741-1C,2C,3C,4C
RFDS DATE: 04/25/2022
REVISION: -
RFDS VERSION: 1.00
RFDS ID: 5153796
CREATED BY: AC7856 DATE: 4/25/2022 4:10:06 PM
UPDATED BY: AC7856 DATE: 4/11/2023 4:14:06 PM
NUMBER OF SECTORS:
3
NUMBER OF ANTENNAS:
6
NUMBER OF TMA'S:
0
NUMBER OF RRH'S:
6
NUMBER OF COAX CABLES:
0
NUMBER OF FIBER/DC SQUID:
2
NUMBER OF FIBER TRUNK CABLES:
2
NUMBER OF DC TRUNK CABLES:
5
NUMBER OF RET CABLES:
1
AT&T
T-1
TITLE SHEET
EQUIPMENT & ANTENNA LAYOUT
A-1
A-4
EQUIPMENT COMPOUND PLAN
A-2
SITE PLAN
T-2
T-3
T-4
SPECIFICATIONS
SPECIFICATIONS
LEGEND & ABBREVIATIONS SPECIFICATIONS
A-3
ELEVATIONS - NEW
3901A160DT, 3901A14ER, 3901A140E6,
3901A160EC, 3901A140BP
LS-1
SITE SURVEY
LS-2
SITE SURVEY
A/C PANEL SCHEDULE & ELECTRICAL ONE-LINE DIAGRAM
E-1
DC PANEL SCHEDULE
E-2
GROUNDING PLANS
E-3
SIGNAGE
A-5
G-1
OVERALL UTILITY PLAN
NOTE: 130' CRANE REQUIRED
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
1
T-2
SPECIFICATIONS
SPECIFICATIONS
1
GENERAL CONSTRUCTION NOTES:
1.
FOR THE PURPOSE OF CONSTRUCTION DRAWING, THE FOLLOWING DEFINITIONS SHALL APPLY:
CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION)
OWNER - AT&T MOBILITY
OEM - ORIGINAL EQUIPMENT MANUFACTURER
2.
PRIOR TO THE SUBMISSION OF BIDS, THE BIDDING CONTRACTOR SHALL VISIT THE CELL SITE TO FAMILIARIZE WITH THE EXISTING CONDITIONS AND TO CONFIRM THAT THE WORK
CAN BE ACCOMPLISHED AS SHOWN ON THE CONSTRUCTION DRAWINGS. ANY DISCREPANCY FOUND SHALL BE BROUGHT TO THE ATTENTION OF OWNER.
3.
ALL MATERIALS FURNISHED AND INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL ISSUE ALL
APPROPRIATE NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY REGARDING THE PERFORMANCE
OF THE WORK. ALL WORK CARRIED OUT SHALL COMPLY WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL JURISDICTIONAL CODES,
ORDINANCES AND APPLICABLE REGULATIONS.
4.
DRAWINGS PROVIDED HERE ARE NOT TO BE SCALED AND ARE INTENDED TO SHOW OUTLINE ONLY.
5.
UNLESS NOTED OTHERWISE, THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS
INDICATED ON THE DRAWINGS.
6.
DELETED.
7.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY STATED OTHERWISE.
8.
IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY
THE CONTRACTOR.
9.
CONTRACTOR SHALL DETERMINE ACTUAL ROUTING OF CONDUIT, POWER AND T1 CABLES, GROUNDING CABLES AS SHOWN ON THE POWER, GROUNDING AND TELCO PLAN
DRAWING. SUBCONTRACTOR SHALL UTILIZE EXISTING TRAYS AND/OR SHALL ADD NEW TRAYS AS NECESSARY. CONTRACTOR SHALL CONFIRM THE ACTUAL ROUTING WITH THE
OWNER. ROUTING OF TRENCHING SHALL BE APPROVED BY OWNER.
10.
THE CONTRACTOR SHALL PROTECT EXISTING IMPROVEMENTS, PAVEMENTS, CURBS, LANDSCAPING AND STRUCTURES. ANY DAMAGED PART SHALL BE REPAIRED AT
CONTRACTOR'S EXPENSE TO THE SATISFACTION OF OWNER.
11.
CONTRACTOR SHALL LEGALLY AND PROPERLY DISPOSE OF ALL SCRAP MATERIALS SUCH AS COAXIAL CABLES AND OTHER ITEMS REMOVED FROM THE EXISTING FACILITY.
ANTENNAS REMOVED SHALL BE RETURNED TO THE OWNER'S DESIGNATED LOCATION.
12.
CONTRACTOR SHALL LEAVE PREMISES IN CLEAN CONDITION.
13.
ALL CONCRETE REPAIR WORK SHALL BE DONE IN ACCORDANCE WITH AMERICAN CONCRETE INSTITUTE (ACI) 301.
14.
ANY NEW CONCRETE NEEDED FOR THE CONSTRUCTION SHALL HAVE 4000 PSI STRENGTH AT 28 DAYS UNLESS OTHERWISE SPECIFIED. ALL CONCRETING WORK SHALL BE DONE
IN ACCORDANCE WITH ACI 318 CODE REQUIREMENTS.
15.
ALL STRUCTURAL STEEL WORK SHALL BE DONE IN ACCORDANCE WITH AISC SPECIFICATIONS.
16.
CONSTRUCTION SHALL COMPLY WITH SPECIFICATION 24782-000-3APS-AOOZ-00002, "GENERAL CONSTRUCTION SERVICES.
17.
CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE
DRAWINGS MUST BE VERIFIED. CONTRACTOR SHALL NOTIFY THE OWNER OF ANY DISCREPANCIES PRIOR TO ORDERING MATERIAL OR PROCEEDING WITH CONSTRUCTION.
18.
THE EXISTING CELL SITE IS IN FULL COMMERCIAL OPERATION. ANY CONSTRUCTION WORK BY CONTRACTOR SHALL NOT DISRUPT THE EXISTING NORMAL OPERATION. ANY
WORK ON EXISTING EQUIPMENT MUST BE COORDINATED WITH OWNER. ALSO, WORK MAY NEED TO BE SCHEDULED FOR AN APPROPRIATE MAINTENANCE WINDOW USUALLY IN
LOW TRAFFIC PERIODS AFTER MIDNIGHT.
19.
SINCE THE CELL SITE MAY BE ACTIVE, ALL SAFETY PRECAUTIONS MUST BE TAKEN WHEN WORKING AROUND HIGH LEVELS OF ELECTROMAGNETIC RADIATION. EQUIPMENT
SHOULD BE SHUTDOWN PRIOR TO PERFORMING ANY WORK THAT COULD EXPOSE THE WORKERS TO DANGER. PERSONAL RF EXPOSURE MONITORS ARE REQUIRED TO BE WORN
TO ALERT OF ANY DANGEROUS EXPOSURE LEVELS.
CONCRETE AND REINFORCING STEEL NOTES:
1.
ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE ACI 301, ACI 318, ACI 336, ASTM A184, ASTM A185 AND THE DESIGN AND CONSTRUCTION SPECIFICATION FOR CAST-IN-PLACE CONCRETE.
2.
ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE.
3.
REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60, DEFORMED UNLESS NOTED OTHERWISE. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185 WELDED STEEL WIRE FABRIC UNLESS NOTED OTHERWISE. SPLICES SHALL BE CLASS "B" AND ALL HOOKS SHALL BE STANDARD, U.N.O.
4.
THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCING STEEL UNLESS SHOWN OTHERWISE ON DRAWINGS:
CONCRETE CAST AGAINST EARTH
3 IN.
CONCRETE EXPOSED TO EARTH OR WEATHER:
#6 AND LARGER
2 IN.
#5 AND SMALLER & WWF
1-1/2 IN.
CONCRETE NOT EXPOSED TO EARTH OR WEATHER, NOR CAST AGAINST THE GROUND:
SLAB AND WALL
3/4 IN.
BEAMS AND COLUMNS
1-1/2 IN.
5.
A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE, U.N.O., IN ACCORDANCE WITH ACI 301 SECTION 4.2.4.
6.
INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL
BE CUT WITHOUT PRIOR ENGINEERING APPROVAL WHEN DRILLING HOLES IN CONCRETE. EXPANSION BOLTS SHALL BE PROVIDED BY RAMSET/REDHEAD OR APPROVED EQUAL.
7.
CONCRETE CYLINDER TEST IS NOT REQUIRED FOR SLAB ON GRADE WHEN CONCRETE IS LESS THAN 50 CUBIC YARDS (UBC 1905.6.1.3) IN THAT EVENT THE FOLLOWING RECORDS SHALL BE PROVIDED BY THE CONCRETE SUPPLIER;
(A) RESULTS OF CONCRETE CYLINDER TESTS PERFORMED AT THE SUPPLIER'S PLANT,
(B) CERTIFICATION OF MINIMUM COMPRESSIVE STRENGTH FOR THE CONCRETE GRADE SUPPLIED. FOR GREATER THAN 50 CUBIC YARDS THE GC SHALL PERFORM THE CONCRETE CYLINDER TEST.
GROUNDING NOTES:
1.
THE CONTRACTOR SHALL REVIEW AND INSPECT THE EXISTING FACILITY GROUNDING SYSTEM AND LIGHTNING
PROTECTION SYSTEM (AS DESIGNED AND INSTALLED) FOR STRICT COMPLIANCE WITH THE NEC (AS ADOPTED BY THE AHJ),
THE SITE-SPECIFIC (UL, LPI, OR NFPA) LIGHTING PROTECTION CODE, AND GENERAL COMPLIANCE WITH TELCORDIA AND
TIA GROUNDING STANDARDS. THE CONTRACTOR SHALL REPORT ANY VIOLATIONS OR ADVERSE FINDINGS TO THE OWNER
FOR RESOLUTION.
2.
ALL GROUND ELECTRODE SYSTEMS (INCLUDING TELECOMMUNICATION, RADIO, LIGHTNING PROTECTION, AND AC POWER
GES'S) SHALL BE BONDED TOGETHER, AT OR BELOW GRADE, BY TWO OR MORE COPPER BONDING CONDUCTORS IN
ACCORDANCE WITH THE NEC.
3.
THE CONTRACTOR SHALL PERFORM IEEE FALL-OF-POTENTIAL RESISTANCE TO EARTH TESTING (PER IEEE 1100 AND 81)
FOR NEW GROUND ELECTRODE SYSTEMS. THE CONTRACTOR SHALL FURNISH AND INSTALL SUPPLEMENTAL GROUND
ELECTRODES AS NEEDED TO ACHIEVE A TEST RESULT OF 5 OHMS OR LESS. TESTS SHALL BE PERFORMED IN
ACCORDANCE WITH 24782-000-3PS-EG00-0001, DESIGN & TESTING OF FACILITY GROUNDING FOR CELL SITES.
4.
METAL RACEWAY SHALL NOT BE USED AS THE NEC REQUIRED EQUIPMENT GROUND CONDUCTOR. STRANDED COPPER
CONDUCTORS WITH GREEN INSULATION, SIZED IN ACCORDANCE WITH THE NEC, SHALL BE FURNISHED AND INSTALLED
WITH THE POWER CIRCUITS TO BTS EQUIPMENT.
5.
EACH BTS CABINET FRAME SHALL BE DIRECTLY CONNECTED TO THE MASTER GROUND BAR WITH GREEN INSULATED
SUPPLEMENTAL EQUIPMENT GROUND WIRES, 6 AWG STRANDED COPPER OR LARGER FOR INDOOR BTS; 2 AWS STRANDED
COPPER FOR OUTDOOR BTS.
6.
EXOTHERMIC WELDS SHALL BE USED FOR ALL GROUNDING CONNECTIONS BELOW GRADE.
7.
APPROVED ANTIOXIDANT COATINGS (I.E., CONDUCTIVE GEL OR PASTE) SHALL BE USED ON ALL COMPRESSION AND
BOLTED GROUND CONNECTIONS.
8.
ICE BRIDGE BONDING CONDUCTORS SHALL BE EXOTHERMICALLY BONDED OR BOLTED WITH STAINLESS STEEL HARDWARE
TO THE BRIDGE AND THE TOWER GROUND BAR.
9.
ALUMINUM CONDUCTOR OR COPPER CLAD STEEL CONDUCTOR SHALL NOT BE USED FOR GROUNDING CONNECTIONS.
10. MISCELLANEOUS ELECTRICAL AND NON-ELECTRICAL METAL BOXES, FRAMES AND SUPPORTS SHALL BE BONDED TO THE
GROUND RING, IN ACCORDANCE WITH THE NEC.
11. METAL CONDUIT AND TRAY SHALL BE GROUNDED AND MADE ELECTRICALLY CONTINUOUS WITH LISTED BONDING FITTINGS
OR BY BONDING ACROSS THE DISCONTINUITY WITH 6 AWG COPPER WIRE UL APPROVED GROUNDING TYPE CONDUIT
CLAMPS.
12.
GROUND CONDUCTORS USED IN THE FACILITY GROUND AND LIGHTNING PROTECTION SYSTEMS SHALL NOT BE ROUTED
THROUGH METALLIC OBJECTS THAT FORM A RING AROUND THE CONDUCTOR, SUCH AS METALLIC CONDUITS, METAL
SUPPORT CLIPS OR SLEEVES THROUGH WALLS OR FLOORS. WHEN IT IS REQUIRED TO BE HOUSED IN CONDUIT TO MEET
CODE REQUIREMENTS OR LOCAL CONDITIONS, NON-METALLIC MATERIAL SUCH AS PVC PLASTIC CONDUIT SHALL BE USED.
WHERE USE OF METAL CONDUIT IS UNAVOIDABLE (E.G., NON-METALIC CONDUIT PROHIBITED BY LOCAL CODE) THE
GROUND CONDUCTOR SHALL BE BONDED TO EACH END OF THE METAL CONDUIT.
13.
ALL TOWER GROUNDING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS OF ANSI/TIA 222. FOR TOWERS BEING BUILT
TO REV G OF THE STANDARD, THE WIRE SIZE OF THE BURIED GROUND RING AND CONNECTIONS BETWEEN THE TOWER
AND THE BURIED GROUND RING SHALL BE CHANGED FROM 2 AWG TO 2/0 AWG. IN ADDITION, THE MINIMUM LENGTH OF THE
GROUND RODS SHALL BE 10 FEET.
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
1
T-3
SPECIFICATIONS
SPECIFICATIONS
1
SITE WORK GENERAL NOTES:
1.
THE CONTRACTOR SHALL CONTACT UTILITY LOCATING SERVICES PRIOR TO THE START OF CONSTRUCTION.
2.
ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC, AND OTHER UTILITIES WHERE ENCOUNTERED IN THE WORK, SHALL BE
PROTECTED AT ALL TIMES, AND WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SHALL BE RELOCATED AS DIRECTED
BY CONTRACTOR. EXTREME CAUTION SHOULD BE USED BY THE CONTRACTOR WHEN EXCAVATING OR DRILLING PIERS AROUND OR
NEAR UTILITIES. CONTRACTOR SHALL PROVIDE SAFETY TRAINING FOR THE WORKING CREW. THIS WILL INCLUDE BUT NOT BE
LIMITED TO A) FALL PROTECTION B) CONFINED SPACE C) ELECTRICAL SAFETY D) TRENCHING & EXCAVATION.
3.
ALL SITE WORK SHALL BE AS INDICATED ON THE DRAWINGS AND PROJECT SPECIFICATIONS.
4.
IF NECESSARY, RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND
DISPOSED OF LEGALLY.
5.
ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHICH INTERFERE WITH THE EXECUTION OF THE
WORK, SHALL BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS WHICH WILL NOT INTERFERE
WITH THE EXECUTION OF THE WORK, SUBJECT TO THE APPROVAL OF CONTRACTOR, OWNER AND/OR LOCAL UTILITIES.
6.
CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION.
7.
THE CONTRACTOR SHALL PROVIDE SITE SIGNAGE IN ACCORDANCE WITH THE AT&T MOBILITY SPECIFICATION FOR SITE SIGNAGE.
8.
THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE BTS EQUIPMENT AND TOWER AREAS.
9.
NO FILL OR EMBANKMENT MATERIAL SHALL BE PLACED ON FROZEN GROUND. FROZEN MATERIALS, SNOW OR ICE SHALL NOT BE
PLACED IN ANY FILL OR EMBANKMENT.
10.
THE SUB GRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION.
11.
THE AREAS OF THE OWNERS PROPERTY DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY,
SHALL BE GRADED TO A UNIFORM SLOPE, AND STABILIZED TO PREVENT EROSION.
12.
CONTRACTOR SHALL MINIMIZE DISTURBANCE TO EXISTING SITE DURING CONSTRUCTION. EROSION CONTROL MEASURES, IF
REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL JURISDICTION'S GUIDELINES FOR EROSION AND
SEDIMENT CONTROL.
ELECTRICAL INSTALLATION NOTES:
1.
WIRING, RACEWAY, AND SUPPORT METHODS AND MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF THE NEC AND TELCORDIA.
2.
CONTRACTOR SHALL MODIFY EXISTING CABLE TRAY SYSTEM AS REQUIRED TO SUPPORT RF AND TRANSPORT CABLING TO THE NEW BTS EQUIPMENT. CONTRACTOR
SHALL SUBMIT MODIFICATIONS TO OWNER FOR APPROVAL.
3.
ALL CIRCUITS SHALL BE SEGREGATED AND MAINTAIN MINIMUM CABLE SEPARATION AS REQUIRED BY THE NEC AND TELCORDIA.
4.
CABLES SHALL NOT BE ROUTED THROUGH LADDER-STYLE CABLE TRAY RUNGS.
5.
EACH END OF EVERY POWER, GROUNDING, AND T1 CONDUCTOR AND CABLE SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND,
1/2 INCH PLASTIC ELECTRICAL TAPE WITH UV PROTECTION, OR EQUAL). THE IDENTIFICATION METHOD SHALL CONFORM WITH NEC & OSHA, AND MATCH EXISTING
INSTALLATION REQUIREMENTS.
6.
POWER PHASE CONDUCTORS (I.E., HOTS)SHALL BE LABELED WITH COLOR-CODED INSULATION OR ELECTRICAL TAPE (3M BRAND, 1/2 INCH PLASTIC ELECTRICAL TAPE
WITH UV PROTECTION, OR EQUAL). PHASE CONDUCTOR COLOR CODE3S SHALL CONFORM WITH THE NEC & OSHA AND MATCH EXISTING INSTALLATION
REQUIREMENTS..
7.
ALL ELECTRICAL COMPONENTS SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS. ALL EQUIPMENT SHALL BE LABELED WITH THEIR VOLTAGE
RATING, PHASE CONFIGURATION, WIRE CONFIGURATION, POWER OR AMPACITY RATING, AND BRANCH CIRCUIT ID NUMBERS (I.E., PANELBOARD AND CIRCUIT ID'S)..
8.
PANELBOARDS (ID NUMBERS) AND INTERNAL CIRCUIT BREAKERS (CIRCUIT ID NUMBERS) SHALL BE CLEARLY LABELED WITH ENGRAVED LAMACOID PLASTIC LABELS.
9.
ALL TIE WRAPS WHERE PERMITTED SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. USE LOW PROFILE TIE WRAPS.
10. POWER, CONTROL, AND EQUIPMENT GROUND WIRING IN TUBING OR CONDUIT SHALL BE SINGLE CONDUCTOR (12 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR
THWN-2, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM USED,
UNLESS OTHERWISE SPECIFIED.
11.
SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED INDOORS SHALL BE SINGLE CONDUCTOR (6 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2 GREEN
INSULATION, CLASS B STRANDED COPPER CABLE RATED FOR 90 °C (WET AND DRY) OPERATION; LISTED OR LABELED FOR THE LOCATION AND RACEWAY SYSTEM
USED, UNLESS OTHERWISE SPECIFIED.
12.
SUPPLEMENTAL EQUIPMENT GROUND WIRING LOCATED OUTDOORS, OR BELOW GRADE, SHALL BE SINGLE CONDUCTOR 2 AWG SOLID TINNED COPPER CABLE, UNLESS
OTHERWISE SPECIFIED.
13. POWER WIRING, NOT IN TUBING OR CONDUIT, SHALL BE MULTI-CONDUCTOR, TYPE TC CABLE (12 AWG OR LARGER), 600 V, OIL RESISTANT THHN OR THWN-2, CLASS B
STRANDED COPPER CABLE RATED FOR 90 °C (WET AND DRY) OPERATION; WITH OUTER JACKET; LISTED OR LABELED FOR THE LOCATION USED, UNLESS OTHERWISE
SPECIFIED.
14.
ALL POWER AND GROUNDING CONNECTIONS SHALL BE CRIMP-STYLE, COMPRESSION WIRE LUGS AND WIRENUTS BY THOMAS AND BETTS (OR EQUAL). LUGS AND
WIRENUTS SHALL BE RATED FOR OPERATION AT NO LESS THAN 75°C (90°C IF AVAILABLE).
15. RACEWAY AND CABLE TRAY SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC.
16. NEW RACEWAY OR CABLE TRAY WILL MATCH THE EXISTING INSTALLATION WHERE POSSIBLE.
17. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO
PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS.
18. ELECTRICAL METALLIC TUBING (EMT), ELECTRICAL NONMETALLIC TUBING (ENT), OR RIGID NONMETALLIC CONDUIT (RIGID PVC, SCHEDULE 40) SHALL BE USED FOR
CONCEALED INDOOR LOCATIONS.
19.
GALVANIZED STEEL INTERMEDIATE METALLIC CONDUIT (IMC) SHALL BE USED FOR OUTDOOR LOCATIONS ABOVE GRADE.
20. RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40 OR RIGID PVC SCHEDULE 80) SHALL BE USED UNDERGROUND; DIRECT BURIED, IN AREAS OF OCCASIONAL
LIGHT VEHICLE TRAFFIC OR ENCASED IN REINFORCED CONCRETE IN AREAS OF HEAVY VEHICLE TRAFFIC.
21. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED.
22. CONDUIT AND TUBING FITTINGS SHALL BE THREADED OR COMPRESSION-TYPE AND APPROVED FOR THE LOCATION USED. SETSCREW FITTINGS ARE NOT
ACCEPTABLE.
23. CABINETS, BOXES, AND WIREWAYS SHALL BE LISTED OR LABELED FOR ELECTRICAL USE IN ACCORDANCE WITH NEMA, UL, ANSI/IEEE, AND NEC.
24. CABINETS, BOXES, AND WIREWAYS TO MATCH THE EXISTING INSTALLATION WHERE POSSIBLE.
25. WIREWAYS SHALL BE EPOXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARD; SHALL BE PANDUIT TYPE E (OR EQUAL); AND
RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS.
26. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPOXY-COATED SHEET STEEL, SHALL MEET OR EXCEED UL
50, AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS.
27. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPOXY-COATED, OR NON-CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1;
AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS.
28. NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED
(WP OR BETTER) OUTDOORS.
29. THE CONTRACTOR SHALL NOTIFY AND OBTAIN NECESSARY AUTHORIZATION FROM THE OWNER BEFORE COMMENCING WORK ON THE AC POWER DISTRIBUTION
PANELS.
30. THE CONTRACTOR SHALL PROVIDE NECESSARY TAGGING ON THE BREAKERS, CABLES AND DISTRIBUTION PANELS IN ACCORDANCE WITH THE APPLICABLE CODS AND
STANDARDS TO SAFEGUARD AGAINST LIFE AND PROPERTY.
STRUCTURAL STEEL NOTES:
1.
ALL STEEL WORK SHALL BE PAINTED IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS AND IN ACCORDANCE WITH ASTM A36
UNLESS OTHERWISE NOTED.
2.
ALL WELDING SHALL BE PERFORMED USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC. WHERE FILLET WELD
SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION". PAINTED
SURFACES SHALL BE TOUCHED UP.
3.
BOLTED CONNECTIONS SHALL BE ASTM A325 BEARING TYPE (3/4"Ø) CONNECTIONS AND SHALL HAVE MINIMUM OF TWO BOLTS
UNLESS NOTED OTHERWISE.
4.
NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8" DIA. ASTM A 307 BOLTS UNLESS NOTED OTHERWISE.
5.
INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR, SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED
PROCEDURE. THE ANCHOR BOLT, DOWEL OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT
DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR CONTRACTOR APPROVAL WHEN DRILLING
HOLES IN CONCRETE. SPECIAL INSPECTIONS, REQUIRED BY GOVERNING CODES, SHALL BE PERFORMED IN ORDER TO MAINTAIN
MANUFACTURER'S MAXIMUM ALLOWABLE LOADS.
6.
ALL EXPANSION/WEDGE ANCHORS SHALL BE STAINLESS STEEL OR HOT DIPPED GALVANIZED. THE ANCHOR BOLT DOWEL AND ROD
SHALL BE STAINLESS STEEL WITH STAINLESS STEEL WASHERS.
SOIL COMPACTION NOTES FOR SLAB ON GRADE:
1.
EXCAVATE AS REQUIRED TO REMOVE VEGETATION & TOPSOIL EXPOSE UNDISTURBED NATURAL SUBGRADE AND PLACE CRUSHED
STONE AS REQUIRED.
2.
COMPACTION CERTIFICATION: AN INSPECTION AND WRITTEN CERTIFICATION BY A QUALIFIED GEOTECHNICAL TECHNICIAN OR
ENGINEER IS ACCEPTABLE.
3.
AS AN ALTERNATIVE TO INSPECTION AND WRITTEN CERTIFICATION, THE "UNDISTURBED SOIL" BASE SHALL BE COMPACTED WITH
"COMPACTION EQUIPMENT", LISTED BELOW, TO AT LEAST 90% MODIFIED PROCTOR MAXIMUM DENSITY PER ASTM D 1557 METHOD C.
4.
COMPACTED SUBBASE SHALL BE UNIFORM & LEVELED. PROVIDE 6" MINIMUM CRUSHED STONE OR GRAVEL COMPACTED IN 3" LIFTS
ABOVE COMPACTED SOIL. GRAVEL SHALL BE NATURAL OR CRUSHED WITH 100% PASSING 1" SIEVE.
COMPACTION EQUIPMENT:
HAND OPERATED DOUBLE DRUM, VIBRATORY ROLLER, VIBRATORY PLATE COMPACTOR OR JUMPING JACK COMPACTOR.
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
T-4
LEGEND & ABBREVIATIONS
GROUND ACCESS WELL
MECHANICAL GRND. CONN.
GROUND ROD
GROUND BUS BAR
NEW ANTENNA
EXISTING ANTENNA
PLYWOOD
GRAVEL
EARTH
(E) MASONRY
CONCRETE
GROUT OR PLASTER
(E) BRICK
EXPANSION
EXP.
GROUND FAULT CIRCUIT INTERRUPTER
GLOBAL POSITIONING SYSTEM
G.F.I.
GLB.(GLU-LAM)
GPS
GLUE LAMINATED BEAM
F.S.
FTG.
G.
GA.
GI.
FT.(')
GALVANIZE(D)
GAUGE
FOOTING
FOOT(FEET)
FINISH SURFACE
GROWTH (CABINET)
FINISH(ED)
FDN.
F.O.W.
F.O.C.
F.O.M.
F.O.S.
FLR.
FACE OF WALL
FACE OF STUD
FOUNDATION
FLOOR
FACE OF MASONRY
FACE OF CONCRETE
FAB.
EXT.
FIN.
F.G.
F.F.
EXST.(E)
FINISH FLOOR
FINISH GRADE
EXTERIOR
FABRICATION(OR)
EXISTING
UNLESS NOTED OTHERWISE
WEIGHT
WT.
CL
PL
PLATE
CENTERLINE
W
V.I.F.
WD.
W.P.
W/
U.N.O.
WITH
WOOD
WEATHERPROOF
WIDE(WIDTH)
VERIFY IN FIELD
UNDERWRITERS LABORATORY
TYP.
T.O.S.
T.O.W.
U.L.
U.G.
T.O.P.
TYPICAL
UNDER GROUND
TOP OF STEEL
TOP OF WALL
TOP OF PLATE (PARAPET)
THK.
T.N.
T.O.C.
T.O.F.
T.O.A.
TEMP.
TOE NAIL
THICK(NESS)
TOP OF CURB
TOP OF ANTENNA
TOP OF FOUNDATION
TEMPORARY
ANTENNA CABLE COVER ASSEMBLY
BARE TINNED COPPER WIRE
ELECTRICAL METALLIC TUBING
CLG.
CEILING
DIAGONAL
DIAG.
ELECTRICAL
ELEC.
E.N.
EMT.
EQ.
ENG.
ELEV.
EQUAL
ENGINEER
EDGE NAIL
ELEVATOR
DWG.
DWL.
DIM.
EL.
EA.
EACH
ELEVATION
DOWEL(S)
DRAWING(S)
DIMENSION
CONTINUOUS
CONT.
DBL.
d
D.F.
DIA.
DEPT.
DEPARTMENT
DOUGLAS FIR
DIAMETER
PENNY (NAILS)
DOUBLE
CLR.
COL.
CONC.
CONN.
CONST.
CLEAR
CONSTRUCTION
COLUMN
CONCRETE
CONNECTION(OR)
ARCHITECT(URAL)
B/U
CAB.
C.I.P.
CANT.
B.O.F.
BTCW.
CABINET
BOTTOM OF FOOTING
CAST IN PLACE
CANTILEVER(ED)
BACK-UP CABINET
BLK.
B.N.
BM.
BLDG.
BLKG.
AWG.
BEAM
BLOCK
BUILDING
BLOCKING
BOUNDARY NAILING
AMERICAN WIRE GAUGE
A.F.F.
ABOVE FINISHED FLOOR
ALT.
ANT.
APPRX.
ARCH.
ALUM.
A.F.G.
ALTERNATE
ALUMINUM
ANTENNA
ABOVE FINISHED GRADE
APPROXIMATE(LY)
ABV.
A.B.
ADD'L
ACCA
ANCHOR BOLT
ABOVE
ADDITIONAL
OPENING
OPNG.
REFERENCE
REF.
SIMILAR
SIM.
SQ.
S.S.
STL.
STD.
SPEC.
STRUC.
SQUARE
STEEL
SPECIFICATION(S)
STANDARD
STRUCTURAL
STAINLESS STEEL
RGS.
SHT.
SCH.
REQ'D.
REINF.
SHEET
REQUIRED
SCHEDULE
RIGID GALVANIZED STEEL
REINFORCEMENT(ING)
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PERSONAL COMMUNICATION SERVICES
POWER PROTECTION CABINET
P.S.F.
P.S.I.
P.T.
PVC.
QTY.
RAD.(R)
QUANTITY
RADIUS
PRESSURE TREATED
POLYVINYL CHLORIDE CONDUIT
PLY.
P/C
PCS
PPC
PRC
PLYWOOD
PRECAST CONCRETE
PRIMARY RADIO CABINET
LONG(ITUDINAL)
(N)
MTL.
O.C.
N.T.S.
MISC.
NO.(#)
NEW
METAL
NUMBER
ON CENTER
MISCELLANEOUS
NOT TO SCALE
M.B.
MAX.
MIN.
MFR.
MAS.
MECH.
MAXIMUM
MINIMUM
MECHANICAL
MACHINE BOLT
MANUFACTURER
MASONRY
ISOLATED COPPER GROUND BUS
ICGB.
INT.
L.F.
L.
L.B.
IN.(")
LB.(#)
INTERIOR
INCH(ES)
POUND(S)
LAG BOLTS
LINEAR FEET (FOOT)
HDR.
HT.
HGR.
GRND.
GROUND
HEADER
HEIGHT
HANGER
SET POINT
FND. MONUMENT
SPOT ELEVATION
LIGHT POLE
TELEPHONE BOX
T
ELECTRIC BOX
E
SECTION REFERENCE
X
X-X
ELEVATION REFERENCE
X-X
X
GRID REFERENCE
X
REVISION
1
MATCH LINE
PROPERTY/LEASE LINE
CENTERLINE
WOOD BLOCKING
STEEL
WOOD CONT.
SAND
OVERHEAD SERVICE
CONDUCTORS
CHAIN LINK FENCING
OH-E/T
TELEPHONE CONDUIT
T
ELECTRICAL CONDUIT
COAXIAL CABLE
(POWER)
E
A
WORK POINT
GROUND CONDUCTOR
ABBREVIATION
DEFINITION
ABBREVIATION
DEFINITION
ABBREVIATION
DEFINITION
LEGEND
ABBREVIATIONS
1
2
CL.
CENTER LINE
GSM.
GLOBAL SYSTEM MOBILE COMMUNICATIONS
UNIVERSAL MOBILE
UMTS.
TELECOMMUNICATIONS SYSTEM
RAN.
RADIO ACCESS NODE
LONG TERM EVOLUTION
LTE.
DETAIL REFERENCE
DETAIL NO.2 ON SHEET E3
INDICATES UNDERGROUND
COAXIAL CABLE, DASHED LINE
TELEPHONE LINE, DASHED LINE
INDICATES UNDERGROUND
INDICATES UNDERGROUND
GROUNDING WIRE, DASHED LINE
TO GROUND HALO
EXOTHERMIC CONNECTION (CADWELD)
TO GROUND RING AND COMPRESSION
HOLE LUG TYPE GROUND CONNECTION
GENERATOR
FUSE
CIRCUIT BREAKER
UTILITY METER
DISCONNECT SWITH
XIT GROUND ROD
GROUND ROD WITH ACCESS
COMPRESSION, CLAMP, OR DOUBLE
LIGHT SWITCH
2
E-3
C
CONDUIT
CIGBE
COAX INSULATED GROUND
BAR EXTERNAL
CO.
CONDUIT ONLY
GEN.
GENERATOR
GROWTH
GR.
INTERIOR GROUND RING (HALO)
IGR.
MIGB
MASTER ISOLATED GROUND BAR
PWR.
POWER (CABINET)
RWY.
RACEWAY
SINGLE LINE DIAGRAM
S.L.D.
TEL
TELEPHONE
TMLP
AT&T
LIMITED PARTNERSHIP
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
SPD WORK
SPACE
T
NEC WORK
SPACE
OVERALL SITE PLAN
1
0"
1500'
750'
1500'
22"x34" SCALE: 1" = 1500'-0"
11"x17" SCALE: 1" = 3000'-0"
A-1
OVERALL SITE PLAN
R
Dial 8-1-1 or 1-800-STAKE-IT (782-5348)
In Maricopa County: (602) 263-1100
Call at least two full working days
before you begin excavation.
Arizona Blue Stake, Inc.
ARIZONA
N
APPROXIMATE LOCATION OF EXISTING PROPERTY LINE, TYP.
PROPOSED AT&T 10' WIDE UTILITY
EASEMENT
PROPOSED AT&T 30'x30' LEASE AREA
AND PROPOSED 8' TALL CMU
WALLED EQUIPMENT COMPOUND
EXISTING BUILDING, TYP.
PROPOSED AT&T 20' WIDE ACCESS & UTILITY
EASEMENT
±430'
±140'
±355'
±80'
±890'
±530'
W. LOWER BUCKEYE RD.
S. PERRYVILLE RD.
NOTE:
MODELSPACE LINEWORK BASED ON GIS MAP AND A SURVEY
BY TERRAMARK LAND SURVEYING, DATED 06/24/2022.
PROPOSED BURIED POWER CONDUIT
FROM EXISTING UTILITY POLE (POWER
SOURCE) TO PROPOSED TRANSFORMER
PROPOSED BURIED FIBER CONDUIT
FROM PROPOSED AT&T FIBER VAULT TO
PROPOSED AT&T FIBER NEMA 4 BOX
EXISTING UTILITY POLE
(POWER SOURCE)
PROPOSED AT&T FIBER VAULT
FUTURE 65' WIDE R.O.W. (PRESERVATION)
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
SPD WORK
SPACE
NEC WORK
SPACE
A-2
EQUIPMENT
COMPOUND PLAN
SITE PLAN
1
0"
30'
30'
15'
22"x34" SCALE: 1" = 30'-0"
11"x17" SCALE: 1" = 60'-0"
N
R
Dial 8-1-1 or 1-800-STAKE-IT (782-5348)
In Maricopa County: (602) 263-1100
Call at least two full working days
before you begin excavation.
Arizona Blue Stake, Inc.
ARIZONA
PROPOSED AT&T 80' TALL MONOPINE
(PENDING FINAL DESIGN BY OTHERS)
PROPOSED AT&T 30'x30' LEASE AREA
AND PROPOSED 8' TALL CMU
WALLED EQUIPMENT COMPOUND
PROPOSED 12' WIDE DOUBLE
SWING ACCESS GATE
9'-0"
12'-0"
9'-0"
PROPOSED AT&T 30'x30' LEASE
AREA W/ PROPOSED STEEL
PLATFORM & EQUIPMENT
(6) PROPOSED 4"Ø SCHED.
80 BURIED CONDUITS
30'-0"
30'-0"
14'-2"
3'-4"
3'-4"
PROPOSED 3-GANG METER BANK
ATTACHED TO PROPOSED CMU WALL
PROPOSED TRANSFORMER
14'-4"
14'-0"
7'-4"
(6) PROPOSED CONCRETE BOLLARDS
3'-6"
TYP.
3'-3"
2'-3"
TYP.
2'-3"
TYP.
3'-6"
3'-0"
4'-0"
4'-0"
2'-4"
2'-0"
TYP.
PROPOSED AT&T GPS UNIT
PROPOSED AT&T ANTENNAS
PROPOSED BOLLARDS, TYP.
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
A-3
ELEVATION - NEW
1
4'
0"
4'
22"x34" SCALE: 3/16" = 1'-0"
11"x17" SCALE: 3/32" = 1'-0"
2'
SOUTH ELEVATION - NEW
EXISTING GRADE = 0'-0"
75'-0" NEW AT&T ANTENNA ARRAY RAD CENTER
79'-0" TOP OF AT&T ANTENNA ARRAY
80'-0" TOP OF PROPOSED MONOPINE
8'-0" COMPOUND WALL
PROPOSED AT&T 80' TALL MONOPINE TOWER
(PENDING FINAL DESIGN BY OTHERS)
PROPOSED AT&T 30'x30' LEASE AREA AND PROPOSED
8' TALL CMU WALLED EQUIPMENT COMPOUND
PROPOSED AT&T 12' WIDE
DOUBLE SWING ACCESS GATE
PROPOSED AT&T ANTENNAS
PROPOSED 3-GANG METER BANK
ATTACHED TO PROPOSED CMU WALL
PROPOSED TRANSFORMER
(6) PROPOSED CONCRETE BOLLARDS
PROPOSED AT&T GPS UNIT
85'-0" TOP OF MONOPINE FRONDS
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
A-4
EQUIPMENT &
ANTENNA LAYOUT
2
2'
0"
2'
22"x34" SCALE: 3/8" = 1'-0"
11"x17" SCALE: 3/16" = 1'-0"
1'
ANTENNA PLAN - NEW
1
1'
0"
1'
22"x34" SCALE: 3/4" = 1'-0"
11"x17" SCALE: 3/8" = 1'-0"
6"
EQUIPMENT PLAN - NEW
N
NOTE:
·
DIMENSIONS ARE SAME FOR ALL SECTORS
N
14'-0"
2"
3'-11"
5"
2'-7"
2'-3"
8'-6"
7'-4"
3"
3'-0"
7"
4'-1"
3'-4"
5'-11"
3"
3'-9"
3'-1"
4"
8"
3'-4"
3'-11"
3'-3"
2'-8"
3'-9"
2'-11"
2'-2"
3'-4"
(N) GRAVITY MOUNT PLATFORM
(N) AT&T GPS UNIT
(N) UNISTRUT RAILING, TYP.
NEW DIESEL NEQ.20574 POLAR POWER, INC.,
8220-100-D-20-03-V,,,,48 VDC; 20KW; DC GENERATOR
HORIZONTAL ENCLOSURE WITH 54 GALLON FUEL TANK
WITH OPV ON NEW GALV. GRAVITY MOUNT PLATFORM
(N) UL LISTED PRE-FABRICATED "W.U.C." EQUIPMENT WALK-UP
CABINET ON NEW GALV. GRAVITY MOUNT PLATFORM
(N) AT&T ACCESS STEP
(N) AT&T SPF CABINET MOUNTED TO UNISTRUT RAILING
(N) AT&T NEC CABINET W/ GEN. RECEPTACLE
MOUNTED TO UNISTRUT RAILING
POSITION 2
POSITION 1
ANTENNA MODEL NUMBER
RRH MODEL NUMBER
ALPHA SECTOR
AZIMUTH
ANDREW-COMMSCOPE - NNH4-65C-R6-V3
0°
INTEGRATED WITHIN AEQ SERIES ANTENNA
POSITION 2
POSITION 1
BETA SECTOR
ANDREW-COMMSCOPE - NNH4-65C-R6-V3
120°
AIRSCALE TRI RRH 4T4R B12/14/29 370W AHLBBA
AIRSCALE DUAL RRH 4T4R B25/66 320W AHFII
POSITION 2
POSITION 1
GAMMA SECTOR
ANDREW-COMMSCOPE - NNH4-65C-R6-V3
240°
ANTENNA SCHEDULE
INTEGRATED WITHIN AEQ SERIES ANTENNA
NOKIA-COMMSCOPE - AEQ SERIES
NOKIA-COMMSCOPE - AEQ SERIES
120°
240°
0°
DETAIL
REF.
DETAIL
REF.
1/D-1.1
2/D-1.1
3/D-1
2/D-1
1/D-1.1
2/D-1.1
NOKIA-COMMSCOPE - AEQ SERIES
NOKIA-COMMSCOPE - AEQ SERIES
1/D-1.1
2/D-1.1
NOKIA-COMMSCOPE - AEQ SERIES
NOKIA-COMMSCOPE - AEQ SERIES
1/D-1.1
2/D-1.1
1/D-1
1/D-1
INTEGRATED WITHIN AEQ SERIES ANTENNA
INTEGRATED WITHIN AEQ SERIES ANTENNA
1/D-1.1
2/D-1.1
INTEGRATED WITHIN AEQ SERIES ANTENNA
INTEGRATED WITHIN AEQ SERIES ANTENNA
1/D-1.1
2/D-1.1
ANTENNA
RAD CENTER
75'
75'
AIRSCALE TRI RRH 4T4R B12/14/29 370W AHLBBA
AIRSCALE DUAL RRH 4T4R B25/66 320W AHFII
3/D-1
2/D-1
1/D-1
1/D-1
AIRSCALE TRI RRH 4T4R B12/14/29 370W AHLBBA
AIRSCALE DUAL RRH 4T4R B25/66 320W AHFII
3/D-1
2/D-1
1/D-1
1/D-1
4'-5"
5'-0"
3'-0"
(1)
(1)
(1)
(2)
(2)
(2)
ALPHA
0° AZIMUTH
BETA
120° AZIMUTH
GAMMA
240° AZIMUTH
PROPOSED AT&T 80' TALL MONOPINE TOWER
(PENDING FINAL DESIGN BY OTHERS)
(2) NEW DC9 SURGE
SUPPRESSOR SQUIDS
NEW AT&T RRH UNITS, (4) PER SECTOR,
(3) SECTORS, (12) TOTAL
-POSITION 1 - (2) RRH UNITS MOUNTED TO NEW BACK TO BACK MOUNT
-POSITION 2 - EMPTY
-POSITION 3 - (2) NEW AT&T RRH UNITS INTEGRATED WITH ANTENNAS
NEW 3-SECTOR T-ARM MOUNT KIT W/
MOUNT REINFORCEMENT KIT
NEW AT&T ANTENNA ARRAY,
(3) ANTENNAS PER SECTOR,
(3) SECTORS, (9) TOTAL
-POSITION 1 - (1) NEW ANTENNA
-POSITION 2 - (2) NEW STACKED ANTENNAS
WITH INTEGRATED RRH UNIT
NEW SITEPRO1 SAMAST3 MOUNT PIPE KIT,
(1) PER SECTOR, (3) SECTORS, (3) TOTAL
75'
75'
75'
75'
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
A-5
SIGNAGE
1
NOT TO
SCALE
GATE SIGN
NO
TRESPASSING
Posted in accordance with Federal Communications Commission rules
on antenna tower registration
47CFR 17.4 (g).
Federal Communications Commission
Tower Registration Number
1 2 3 4 5 6 7
INFORMATION
COMBUSTIBLE
FLAMMABLE
NO SMOKING
1
2
0
DIESEL
1
4
0
PROPANE
INFORMATION
Contact AT&T Mobility at _____________ and follow their
instructions prior to performing any maintenance or repairs
closer than 3 feet from the antennas.
This is AT&T Mobility site _____________
AT&T Mobility
En esta propiedad se ubican antenas de
telecommunicaciones operadas por AT&T Mobility. Favor
mantener una distancia de no menos de 3 pies y obedecer
todos los avisos.
Comuniquese con el propietario o los propietarios de las
antenas antes de trabajar o caminar a una distancia de
menos de 3 pies de la antena
Comuniquese con AT&T Mobility ________________ antes
de realizar cualquier mantenimiento a reparaciones cerca
de las antenas de AT&T Mobility.
Esta es la estación base número ____________________
Favor comunicarse can la oficina de la administración del
edificio si esta puerta o compuerta se encuentra sin
candado
AT&T Mobility operates telecommunications antennas at
this location. Remain at least 3 feet away from any
antenna and obey all posted signs.
Contact the owner(s) of the antenna(s) before working
closer then 3 feet from the antenna(s)
Contact AT&T Mobility at _____________ prior to
performing any maintenance or repairs near AT&T
antennas
This is site# ____________________
Contact the management office if this door/hatch/gate is
found unlocked.
INFORMATION
INFORMACION
3
DOOR SIGN
2
4
5
6 FUEL STORAGE SIGN
NO TRESPASSING SIGN
FCC TOWER REG. (ASRN)
RADIO FREQUENCY INFORMATION SIGN
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
E-1
A/C PANEL SCHEDULE &
ELECTRICAL ONE-LINE DIAGRAM
A/C PANEL SCHEDULE & ELECTRICAL ONE-LINE DIAGRAM
NOT TO
SCALE
1
DC GENERATOR TO POWER PLANT WIRING
(1) 4/0 AWG
M
M
M
450A
G
J
J
J
400A
X
X
RECTIFIERS 1 & 2
RECTIFIERS 3 & 4
RECTIFIERS 5 & 6
RECTIFIERS 7 & 8
RECTIFIERS 9 & 10
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
E-2
DC PANEL
SCHEDULE
DC PANEL SCHEDULE EMERSON NETSURETM 7100 BREAKER SCHEDULE
NOT TO
SCALE
1
NOTES:
1. BREAKER SIZES 125A TO 200A OCCUPY TWO POSITIONS. 225A AND 250A BREAKERS OCCUPY THREE POSITIONS.
2. ALL BREAKERS RATED 100A AND GREATER SHALL HAVE ONE EMPTY SPACE BETWEEN OTHER BREAKERS.
3. 2-POSITION AND 3-POSITION BREAKERS REQUIRE AN ADAPTER PLATE ON LOAD TERMINALS.
4. LOAD AND RETURN TERMINAL STUDS ARE 1/4"-20 ON 5/8" CENTER.
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
SPD WORK
SPACE
NEC WORK
SPACE
E-3
OVERALL
UTILITY PLAN
OVERALL UTILITY PLAN
1
22"x34" SCALE: 1-1/2" = 1'-0"
11"x17" SCALE: 3/4" = 1'-0"
1'
0'
6"
N
PROPOSED AT&T 200A METER
ATTACHED TO PROPOSED CMU WALL
PROPOSED AT&T FIBER NEMA 4 BOX W/ CONDUIT
RISER ATTACHED TO PROPOSED CMU WALL
PROPOSED AT&T 200A DISCONNECT
ATTACHED TO PROPOSED CMU WALL
PROPOSED AT&T 30'x30' LEASE AREA
AND PROPOSED 8' TALL CMU
WALLED EQUIPMENT COMPOUND
PROPOSED AT&T 10' WIDE UTILITY EASEMENT
PROPOSED BURIED POWER CONDUIT FROM PROPOSED
TRANSFORMER TO PROPOSED AT&T 200A METER
PROPOSED TRANSFORMER W/
(4) PROPOSED CONCRETE BOLLARDS
PROPOSED BURIED FIBER CONDUIT FROM PROPOSED AT&T FIBER
VAULT (NOT VISIBLE, SEE SHEET A-1) TO PROPOSED AT&T NEMA 4 BOX
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
SPD WORK
SPACE
NEC WORK
SPACE
E-4
ENLARGED
UTILITY PLAN
OVERALL UTILITY PLAN
1
22"x34" SCALE: 1-1/2" = 1'-0"
11"x17" SCALE: 3/4" = 1'-0"
1'
0'
6"
N
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
MGB
N
GROUND INSPECTION WELL
EXOTHERMIC CONNECTION
MECHANICAL CONNECTION
ANTENNA GROUND BAR
MASTER GROUND BAR
LEGEND
NOTE:
·
ALL NEW EQUIPMENT MUST BE GROUNDED TO
GROUND RING OR HALO PER AT&T SPECIFICATIONS
·
CONTRACTOR TO REPLACE ALL MISSING GROUND
BARS AND GROUNDING CONNECTIONS AS REQUIRED.
MGB
EXOTHERMIC CONNECTION
MECHANICAL CONNECTION
ANTENNA GROUND BAR
MASTER GROUND BAR
LEGEND
NOTE:
·
ALL NEW EQUIPMENT MUST BE GROUNDED TO
GROUND RING OR HALO PER AT&T SPECIFICATIONS
·
CONTRACTOR TO REPLACE ALL MISSING GROUND
BARS AND GROUNDING CONNECTIONS AS REQUIRED.
G-1
GROUNDING PLANS
NOTE:
#2 AWG GREEN STRANDED COPPER WIRE
TO EXISTING MASTER GROUND BAR
2
2'
1'
0"
2'
22"x34" SCALE: 1/2" = 1'-0"
11"x17" SCALE: 1/4" = 1'-0"
TOWER ARRAY GROUNDING PLAN - NEW
1
1'
0"
1'
22"x34" SCALE: 3/4" = 1'-0"
11"x17" SCALE: 3/8" = 1'-0"
6"
EQUIPMENT GROUNDING PLAN - NEW
NOTE:
·
DIMENSIONS ARE SAME FOR ALL SECTORS
·
EXISTING BALL FIELD LIGHTS NOT SHOWN FOR CLARITY
N
BOND GENERATOR GROUND LUG TO THE NEW
GROUND RING W/#2 SOLID TINNED COPPER WIRE,
TYP 2 PLACES
BOND WUC GROUND LUG TO THE NEW
GROUND RING W/#2 SOLID TINNED COPPER WIRE,
TYP 2 PLACES
GROUND RING IS TO BE CONSTRUCTED OF #2
SOLID TINNED BARE COPPER WIRE IN ONE
CONTINUOUS PIECE, IF POSSIBLE .
AT A DEPTH OF AT LEAST 30 INCHES BELOW
GRADE , OR 6 INCHES BELOW THE FROST LINE. DO
DEVIATIONS ALLOWED
5/8" DIAMETER X 10'-0" COPPER GROUND ROD
INSTALLED EVERY 10'-0" AND CADWELDED TO
GROUND RING.
GROUND ROD TEST WELL (2 LOCATIONS).
VERIFY EXACT LOCATIONS WITH AT&T C.M.
#2 SOLID TINNED BARE COPPER GROUND WIRE
FROM SPD TO GROUND RING
4'-5"
5'-0"
3'-0"
(1)
(1)
(1)
(2)
(2)
(2)
ALPHA
0° AZIMUTH
BETA
120° AZIMUTH
GAMMA
240° AZIMUTH
PROPOSED AT&T 80' TALL MONOPINE TOWER
(PENDING FINAL DESIGN BY OTHERS)
(2) NEW DC9 SURGE
SUPPRESSOR SQUIDS
NEW AT&T RRH UNITS, (4) PER SECTOR,
(3) SECTORS, (12) TOTAL
-POSITION 1 - (2) RRH UNITS MOUNTED TO NEW BACK TO BACK MOUNT
-POSITION 2 - EMPTY
-POSITION 3 - (2) NEW AT&T RRH UNITS INTEGRATED WITH ANTENNAS
NEW 3-SECTOR T-ARM MOUNT KIT W/
MOUNT REINFORCEMENT KIT
NEW AT&T ANTENNA ARRAY,
(3) ANTENNAS PER SECTOR,
(3) SECTORS, (9) TOTAL
-POSITION 1 - (1) NEW ANTENNA
-POSITION 2 - (2) NEW STACKED ANTENNAS
WITH INTEGRATED RRH UNIT
NEW SITEPRO1 SAMAST3 MOUNT PIPE KIT,
(1) PER SECTOR, (3) SECTORS, (3) TOTAL
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
CHECKED BY:
DRAWN BY:
SHEET TITLE:
REV.:
SHEET NUMBER:
C
DATE
PROJECT INFORMATION:
REVISION DESCRIPTION
REV.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND
MATERIALS IN ACCORDANCE WITH MANUFACTURES
RECOMMENDATIONS AND SPEC'S, UNLESS SPECIFICALLY
STATED OTHERWISE, THE MANUFACTURES EQUIPMENT
INSTALLATION SPEC'S SHALL ALWAYS BE VERIFIED BY THE
CONTRACTOR BEFORE INSTALLATION
CE
AS
THE INFORMATION CONTAINED IN THIS SET OF DRAWINGS IS
PROPRIETARY & CONFIDENTIAL TO AT&T WIRELESS
ANY USE OR DISCLOSURE OTHER THAN AS IT RELATES TO AT&T
WIRELESS IS STRICTLY PROHIBITED
8767 E. VIA DE VENTURA
SUITE 200
SCOTTSDALE, AZ 85258
FA: 15458424
USID: 319680
AZL01741
LEISTER FARMS
19029 W. LOWER BUCKEYE RD.
BUCKEYE, AZ 85326
MARICOPA COUNTY
PRELIMINARY
FOR REVIEW
1355 WEST UNIVERSITY DRIVE
MESA, AZ 85201-5419
AT&T
01/23/2023
ISSUED FOR PERMIT
A
04/27/2023
REDLINES
B
05/23/2023
FUTURE R.O.W.
C
SPD WORK
SPACE
NEC WORK
SPACE
N
MGB
EXOTHERMIC CONNECTION
MECHANICAL CONNECTION
ANTENNA GROUND BAR
MASTER GROUND BAR
LEGEND
NOTE:
·
ALL NEW EQUIPMENT MUST BE GROUNDED TO
GROUND RING OR HALO PER AT&T SPECIFICATIONS
·
CONTRACTOR TO REPLACE ALL MISSING GROUND
BARS AND GROUNDING CONNECTIONS AS REQUIRED.
G-2
GROUNDING PLANS
NOTE:
#2 AWG GREEN STRANDED COPPER WIRE
TO EXISTING MASTER GROUND BAR
2
2'
1'
0"
2'
22"x34" SCALE: 1/2" = 1'-0"
11"x17" SCALE: 1/4" = 1'-0"
OVERALL GROUNDING PLAN - NEW
Project Name: AZL01741 – Leister Farms
May 8, 2023
Company: SmartLink on behalf of AT&T
Contact: Michael Hanna
Phone: 951-319-1341
Email: michael.hannna@smartlinkgroup.com
Special Use Permit Application Addendum 4: Project Narrative for Z2023032
Introduction
AT&T is looking to expand coverage in the Buckeye area by locating a proposed wireless
communications facility at 19029 W Lower Buckeye Rd, Buckeye AZ 85326 (APN #: 502-48-
002K), as part of a larger coverage project for the Arizona market. This project serves to provide
coverage for the Las Brisas Residential Community, the Los Ranchitos area and the surrounding
agricultural fields. This project is also looking to expand FirstNet coverage in order to better aid
first responders within the surrounding area.
Alternative Site Analysis
There are two existing Wireless Communication Facilities (“WCF”) located within the area. The
first tower is located 1.8 miles southwest of the proposed location, at Jackrabbit Nursery (4421 S
Jackrabbit Trail, Buckeye, AZ 85326). Verizon Wireless is the tower owner for this site and
currently has two antenna arrays located on the tower. This tower was deemed to non-viable for
AT&T’s purposes, as the Prime Landlord was not interested in leasing the necessary ground space
and was too far away from the search ring coordinates to adequately satisfy AT&T’s coverage
objectives.
The second tower is located 2.1 miles southeast of the proposed location, off the intersection of W
Broadway Road and S 175th Avenue. SBA is the tower owner for this site and currently has a
single antenna array located on the tower. This tower was deemed non-viable for AT&T’s purpose,
as it is too far away from the search ring coordinates to adequately satisfy AT&T’s coverage
objectives
For the reasons stated above, AT&T determined that collocation would not be a viable alternative
in this location in order to meet the coverage objectives they desire. As such, AT&T proposes a
new, multi-carrier facility located at 19009 W Lower Buckeye Road to satisfy their objectives.
Site Details
The proposed AT&T facility is designed to be a multi-carrier facility disguised as a pine tree.
Alternative designs were considered for the project, such as a palm tree, but were rejected due to
the desire to have this site maximize colocation opportunities. Palm tree designs can only
adequately collocate two carriers in a stealth design, whereas this design can accommodate four
carriers. The subject property is designated as a RU-43 (Rural 43-acre) zone. The tower will be
constructed at the maximum height for a RU-43 designated zone at 80ft. Furthermore, the tower
will conform to the setback ratio of 2:1 tower height from all property lines and the ground
equipment will be screened with an 8’ solid CMU block wall.
The specific location on the subject parcel is towards the South end of the parcel, locating on a
currently undeveloped part of the land near barns and other buildings used for agricultural
purposes. There will be adequate parking for the maintenance and installation crew that will work
on initial construction and ongoing maintenance of the site. Site will be accessed via an existing
road used by the Landowner for farming vehicles abutting the westernmost side of the parcel.
Paving of the site will include paving the ground equipment area (30’ x 30’ lease area) and laying
down foundation for the tower base. Timeframe for construction is likely to begin early next year.
No other utility providers besides fiber optic and power providers are necessary for this site.
Conformance to Codes/Ordinances
The surrounding parcels in the immediate area have the following make-up of zoning designations:
North: Medium Residential (City of Buckeye Jurisdiction)
South: Medium Residential (City of Buckeye Jurisdiction)
East: RU-43 Rural 43-Acre
West: Medium Residential (City of Buckeye Jurisdiction)
Per Maricopa County Zoning Ordinance Section 1202.2.1, WCF’s are allowed in all zones, subject
to further provisions laid out in Section 1202. Per Section 1202.3.1, Wireless Communication
Facilities are deemed permitted in Rural designated parcels subject to the limitations laid out in
that same provision. AT&T performed due diligence in finding a location that would provide the
least-intrusive means to the surrounding area. Sites are determined on a variety of factors: a)
willing landlord; b) sufficient ground elevation and favorable topography (relatively flat areas for
antenna signals to propagate farther distances); c) construction viability, including ease of
installation, nearby utilities and ongoing maintenance access; and d) as permitted by state and local
ordinances. Of the locations reviewed to date, the subject parcel is the only location that meets the
above parameters.
Once the site is installed, foot traffic to the site will be minimal; only for ongoing monthly
maintenance by each carrier save for emergency maintenance. All equipment will be operated
within noise standards consistent with the city’s guidelines.
Once on-air, the WCF will comply with FCC guidelines for human exposure to RF electromagnetic
fields, and cumulative exposure from all the facilities will meet FCC guidelines.
Krystina Pacheco, PE
Planning & Development
301 W. Jefferson St., Suite 170
Phoenix, Arizona 85003
Phone: (602) 506-8790
www.maricopa.gov/planning
Email address:
krystina.pacheco@maricopa.gov
Planning & Development
Engineering Plan Review
Date:
May 23, 2023
Memo To:
Darren Gerard, Planning Manager, Planning & Development
Attn:
Andrew Lorentzen, Planner, Planning and Development
From:
Krystina Pacheco, P.E., Plans Examiner Engineer, Planning and
Development
cc:
Michael Norris, P.E., Engineering Manager, Planning and Development
Subject:
Z2023032 – SUP to Install Cell Tower
(E2 Memo)
Job Site Address:
19027 W Lower Buckeye Road, Buckeye
APN(s):
502-48-002K
PND engineering plan review (DPR, FCD and PND Transportation) has reviewed the 1st
submittal of the SUP application routed for review on May 23, 2023. PND Engineering has
no comments or objections subject to the following conditions:
1. Lower Buckeye Road is classified as a principal arterial, and 65-feet preservation is
required from the section line.
2. Driveway access to County roads must be paved and will require a permit from
MCDOT issued concurrent with building permit(s) required for site development. OR;
provide documentation that a paved driveway access is not required per MCDOT at
the time of application for a building permit.
3. The applicant must execute a Wireless Agreement with MCDOT for all equipment,
conduit, F/O and other work that will be within the MCDOT ROW. This agreement
must be coordinated with Ms. Kelly Roy, MCDOT Utility Branch Coordination
Manager, 602-506-8603 or Kelly.Roy@maricopa.gov. OR; provide documentation
that a wireless agreement is not required at the time of application for a building
permit.
4. All development and engineering design shall be in conformance with Section 1205
of the Maricopa County Zoning Ordinance; Drainage Policies and Standards;
Floodplain Regulations for Maricopa County; MCDOT Roadway Design Manual;
and current engineering policies, standards and best practices at the time of
application for construction.
Page 2 of 2
5. Engineering review of planning and/or zoning cases is for conceptual design only and
does not represent final design approval nor shall it entitle applicants to future
designs that are not in conformance with Section 1205 of the Maricopa County Zoning
Ordinance and Drainage Policies and Standards; Floodplain Regulations for Maricopa
County; and the MCDOT Roadway Design Manual.
Please contact me if you have any questions or require any additional information.
1
Andrew Lorentzen (PND)
From:
Ken Galica <kgalica@buckeyeaz.gov>
Sent:
Thursday, March 16, 2023 2:41 PM
To:
Andrew Lorentzen (PND)
Cc:
Adam Copeland; Hobart Wingard; Brian Craig
Subject:
RE: Z2023032 - AZL01741 – Leister Farm
Attachments:
Z2023032 - BLDG-PLAN.PDF.pdf; Z2023032 - NARR-DETL.DOCX.docx; Z2023032 - PRCL-
DETL.PDF.pdf
Good afternoon, Andrew:
The City of Buckeye has no concerns with the request for a proposed 80’ tall cell tower on the subject parcel. One
recommendation, though, would be to change the tower design from a monopine to a monopalm given the site already
has several mature, fairly tall palm trees that would help create some context and camouflage for the tower.
If you have any questions, let me know.
Thanks!
Ken Galica
Principal Planner
Development Services Department
(623) 349‐6214
From: Andrew Lorentzen (PND) <Andrew.Lorentzen@maricopa.gov>
Sent: Thursday, March 16, 2023 2:11 PM
To: dhenning@westvalleyview.com; Jon.Lacy@bvfd.az.gov; Mark.burdick@bvfd.az.gov; ken.nyman@azag.gov;
56fw.cit.communityinitiative@us.af.mil; Ken Galica <kgalica@buckeyeaz.gov>; dmheisler1@aol.com;
Alissa.magley@goodyearaz.gov; christopher.baker@goodyearaz.gov; Katie.wilken@goodyearaz.gov;
swilken@azmag.gov; Kurt Cotner <kcotner@azmag.gov>; agarza@azmag.gov; bfenske@azdot.gov; jgarcia@azdot.gov;
Dkrantz@citytocitycre.com; michael.hanna@smartlinkgroup.com
Subject: Z2023032 ‐ AZL01741 – Leister Farm
[NOTICE: This message originated outside of the City of Buckeye ‐‐ DO NOT CLICK on links or
open attachments unless you are sure the content is safe.]
Hello Registered Area of Interest Member,
Please find attached a planning & development application routing for Z2023032.
See attached document for instructions to download application materials.
Thank you,
2
Andrew Lorentzen
Planner
PLANNING & DEVELOPMENT
301 W. Jefferson St. Suite 170
Phoenix, AZ 85003
O: 602-506-2364
MARICOPA.GOV
Andrew.lorentzen@maricopa.gov
Facebook | Instagram | Twitter | YouTube | LinkedIn
This message contains confidential information and is intended only for the individual(s) addressed in the message. If
you are not the named addressee, you should not disseminate, distribute, or copy this e‐mail. If you are not the
intended recipient, you are notified that disclosing, distributing, or copying this e‐mail is strictly prohibited.