05. MCP2022009 PZ Report
Extracted text (via pymupdf)
37646 characters
MCP2022009 Page 1 of 6 Report to the Planning and Zoning Commission Prepared by the Maricopa County Planning and Development Department Case: MCP2022009 – Sheila AZ45116 Hearing Date: April 20, 2023 Supervisor District: 4 Applicant: Nicole Comach, Virtual Walk LLC Owner: 13649 W. Northern LLC Request: Military Compatibility Permit (MCP) with a Plan of Development (POD) for a Wireless Communication Facility within the Rural-43 MAAMF zoning district. Site Location: Generally located on the SEC of Northern Avenue and Litchfield Rd. in the Glendale Area Site Size: Approx. 2.34 acres Density: N/A County Island: Yes, City of Glendale County Plan: White Tank Grand Avenue Area Plan – Military Compatible Municipal Plan: N/A Municipal Comments: None received to date Support/Opposition: None known Recommendation: Approve with conditions MCP2022009 Page 2 of 6 Project Summary: 1. The applicant, Nicole Comach on behalf of Vertical Site Walk LLC, is requesting a Military Compatibility Permit (MCP) with a Plan of Development (POD) to allow an existing wireless communication facility on 986 sq. ft. of the 2.34-acre site located northeast of Luke Air Force Base (LAFB). The wireless communication facility consists of a 110’ monopole and a 339 sq. ft. AT&T Shelter. The existing tower was previously approved under Special Use Permit Case Z97- 32, but expired October 2022. The applicant is not proposing any changes to the existing tower. 2. The site is within the City of Glendale’s municipal planning area. The Glendale General Plan Designates the property as Luke Compatible, which is applied to lands surrounding LAFB. Similarly, the county’s area plan designates the general area for Military Compatible land uses. This designation coincides with the Military Airbase and Ancillary Military Facility Overlay Zoning District (MAAMF). A portion of the lot on the northwest corner is within the clear zone meant to prevent development that would encroach on LAFB’s runways. Projects located within the MAAMF must first obtain a Use Compatibility and Consistency Determination (UCCD) prior to being able to apply for a Military Compatibility Permit (MCP). LAFB determined that this proposed cell tower use is consistent and compatible with the high noise or accident potential zone per UC2022022. 3. The earliest available aerial photography of the site from 1949 indicates it as farmland directly bordering LAFB to the southwest. In 1997 the subject site was developed with a wireless communications facility. Additionally, a separate parcel to the south, 501-52-005L, will be developed as a warehouse complex and is not part of the subject entitlement. The applicant filed and was approved for a UCCD from LAFB, UC2022022, in November of 2022. The applicant applied for the subject MCP with POD in December of 2022. 2022 Site Aerial MCP2022009 Page 3 of 6 Rural – 43 Military Airport and Ancillary Military Facility Overlay District & Surrounding Districts Existing Site Plan MCP2022009 Page 4 of 6 Existing Elevations Existing On-Site and Adjacent Zoning / Land Use: 4. On-site: Rural-43 MAAMF / Wireless Communication Facility North: Northern Avenue then Rural-43 MAAMF / Agriculture Land South: IND-2 MAAMF / Vacant Land East: IND-2 MAAMF / Vacant Land West: IND-2 MAAMF / Vacant Land Utilities and Services: 5. Water: Valley Utilities Wastewater: Liberty Water School District: Dysart Unified School District Fire: Rural Metro Police: MCSO Right-of-Way: 6. The following table includes existing and proposed half-width right-of-way and the future classification based upon the Maricopa County Department of Transportation (MCDOT) Major Streets and Routes Plan. Litchfield Rd is under the City of Glendale’s jurisdiction. Street Name Half-width Existing R/W Half-width Proposed R/W Future Classification Northern Ave. 33’ N/A Urban Minor Arterial Adopted Plans: 7. White Tank/Grand Avenue Area Plan (Revised: 2020): This plan identifies the subject parcel as Military Compatible Land Use Area. Luke Air Force Base muse issue a Use Consistency and Compatibility Determination (UCCD) prior to a use being allowed in this area. MCP2022009 Page 5 of 6 8. City of Glendale General Plan (Revised 2016): This plan identifies the subject parcel as a Luke Compatible Land Use Area. Public Participation Summary: 9. The applicant complied with the Maricopa County Public Participation Process with the required posting of the property and the notification to the adjacent property owners within 300’ of the subject site. Staff has not received any notice of opposition or support to the request. LAFB sent staff comments stating the request will not negatively impact flying operations at the base. Outstanding Concerns from Reviewing Agencies: 10. N/A. Staff Analysis: 11. The Military Airport and Ancillary Military Facility Overlay became effective in 2008, after the existing wireless communication facility use was established in 1997. Staff believes that the continuation use of the Wireless Communication Facility is appropriate for the site as it will remain as is. LAFB found that the existing land use is consistent and compatible with the High Noise and Accident Potential Zone of the base, and that it would not negatively impact flying operations. As such, Maricopa County can make a similar determination of compatibility and consistency. Recommendation: 12. For the reasons outlined in this report, staff recommends the Commission adopt a motion recommending that the Board of Supervisors approve MCP2022009, subject to the following conditions ‘a’ – ‘g’: a. Development of the site shall be in substantial conformance with the Site Plan entitled “Military Compatibility Permit”, consisting of 6 pages, dated February 2, 2023, except as modified by the following conditions. b. Development of the site shall be in substantial conformance with the Narrative Report entitled “Shelia/AZ45116 Narrative Report”, consisting of 3 pages, dated February 20, 2023, except as modified by the following conditions. c. Major amendments to the site plan will require a new UCCD and MCP application to be filed prior to any permit approvals. The incorporation of any other parcels into this project will require a lot combination, new UCCD, and new MCP prior to any additional permit approvals. d. The height of the wireless communication facility shall be limited to 110 feet. e. The property owner/s and their successors waive claim for diminution in value if the County takes action to rescind approval due to noncompliance with conditions. MCP2022009 Page 6 of 6 f. Noncompliance with any Maricopa County regulation shall be grounds for initiating revocation of this Military Compatibility Permit as set forth in the Maricopa County Zoning Ordinance. g. The granting of this change in use of the property has been at the request of the applicant, with consent of the landowner. The granting of this approval allows the property to enjoy uses in excess of those permitted by the zoning existing on the date of application, subject to conditions. In the event of the failure to comply with any condition, the property shall revert to the zoning that existed on the date of application. It is, therefore, stipulated and agreed that either revocation due to the failure to comply with any conditions, does not reduce any rights that existed on the date of application to use, divide, sell or possess the property and that there would be no diminution in value of the property from the value it held on the date of application due to such revocation of the MCP. The MCP enhances the value of the property above its value as of the date the MCP is granted and reverting to the prior zoning results in the same value of the property as if the MCP had never been granted. Presented by: Paola Jaramillo, Planner Reviewed by: Darren Gerard, AICP, Planning Supervisor Attachments: Case Map (1 page) Application (1 page) Narrative Report (6 pages) Site Plan (6 pages) Engineering comments (2 pages) MCESD comments (1 page) / Maricopa County Planning & Development - Phoenix, AZ 4 Gross Acres: 1 approx. Generated March 30, 2023 11:21 AM MCP2022009 Application Name: Legal Description Sheila AZ45116 Applicant Case Address T02N R01W 3, NICOLE COMACH for VIRTUAL SITE WALK, LLC 13649 W NORTHERN Ave Applicant Phone/Email Parcel Primary:501-52-003A 541.228.4823 NICOLE@VIRTUALSITEWALK.COM GLENDALE AZ 85307 Map scale 1:917 Supervisor District No. SHELIA/AZ 45116 5.3585 in 2/28/2023 February 20, 2023 NARRATIVE REPORT PREVIOUS PERMIT#: Case No.: Z97-32 CURRENT CASE #: MCP2022009 SITE NAME: Shelia/AZ45116 SITE ADDRESS: 13649 W. Northern Ave., Glendale, AZ 85023 APN: 501-52-003B B: Purpose of Request SBA 2012 TC Assets, LLC, herein referenced as the Applicant, is requesting the Military Compatibility Permit to continue the use of an existing Wireless Telecommunications Facility that was approved under Z97-32 but has expired. The applicant proposes no alteration to its existing Wireless Telecommunications Facility located at the address above. C: Description of Proposal This is an existing Wireless Telecommunications Facility. There is no proposed construction, modifications, or height increase at this time. We propose to continue the use of the facility. The Monopole exists at 110-feet in height, with the top of the lightning rod at 112-feet. The tower consists of panel antennas, all with the New Cingular Wireless carrier. The equipment compound is located on the ground directly next to the monopole. Both the tower and equipment are behind a fence with 24-hour locked access D: Relationship to Surrounding Properties Our subject parcel is in a Rural (R-43) zone. Surrounding parcels are mostly zoned Industrial (IND-2). This site provides continued telecommunications coverage to the community, including enhanced emergency response, better reception quality and higher security and privacy for telephone users. The project continues to fit the intended goals because it would reduce risk of injury or death through enhanced cellular phone service, would promote efficiency of public services through enhanced cellular phone service, and does not generate a large amount of traffic, noise, congestion or odors. This project does not increase visual blight in the surrounding area because the applicant proposes no changes to the existing site. E: Location and Accessibility The facility is located at 13649 W. Northern Ave., Glendale, AZ 85023; APN: 501-52-003A. The equipment compound is located on the ground directly next to the monopole. Both the tower and equipment are behind a fence with 24-hour locked access. To secure the wireless facility from access by all persons other than authorized personnel, there will continue to be locked access where the equipment is located. F: Relationship to State Statute The facility is a Monopole and this department approved the project as constructed, and implemented Conditions of Approval to ensure that it was completed using the least intrusive means necessary. Because there are no changes to the existing site, the use will not be contrary to the character or performance standards established for Maricopa County, in which it is located. A Noise Study is available upon request. G: Circulation System N/A as there are no proposed modifications or construction. H: Development Schedule N/A as there are no proposed modifications or construction. I: Community Facilities and Services Our subject parcel is in a Rural (R-43) zone. Surrounding parcels are mostly zoned Industrial (IND-2). J: Public Utilities and Services The applicant is not proposing any change in the use or technology with this application. The facility does not require the use of public services. K: Other Helpful Information No new co-location issues exist since this is a request for the continued use of an existing wireless facility only. The Applicant agrees to continue complying with all cosmetic and other maintenance requirements. Along with the Military Compatibility Permit Application for renewing the Conditional Use Permit for this facility, the applicant is submitting Site Plans showing what the tower looks like currently. The applicant is not proposing any change in the use or technology with this application. Thank you for your consideration. V-B SBA 2012 TC ASSETS, LLC 8051 CONGRESS AVE BOCA RATON, FL 33487 APPLICANT: DRAWING INDEX AZ45116 13649 WEST NORTHERN AVE GLENDALE, AZ 85307 07/27/22 08/02/22 02/21/23 A 0 1 90% CUP REVIEW 100% FINAL CUP JURISDICTION COMMENTS NO. DATE REVISION DRAWN RA KM YK CONSULTANT: A&E CONSULTANT, SITE ACQUISITION AND PERMITTING: SHELIA NOTE: THE PURPOSE OF THIS PROJECT IS THE REQUEST A MILITARY COMPATIBILITY PERMIT FOR THE CONTINUATION USE OF THE MONOPOLE ON THE SITE. 13649 W NORTHERN LLC 1545 W EL CAMINITO DR PHOENIX AZ, 85021 PROPERTY OWNER: COVER SHEET T-1 PROJECT CONTACT LIST AREA MAP LEGAL DESCRIPTION DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CONSULTING. THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF T-MOBILE AND MAY NOT BE REPRODUCED, DISSEMINATED OR REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF T-MOBILE. SCOPE OF WORK NORTH LOCATION MAP NORTH PROJECT: MILITARY COMPATIBILITY PERMIT CASE NUMBER: MCP2022009 SITE NAME: SHELIA SBA SITE NUMBER: AZ45116 SITE ADDRESS: 13649 WEST NORTHERN AVE GLENDALE, AZ 85307 SITE TYPE: N 33° 33' 03.66" N 33.55101667° LATITUDE (NAD83): W -112° 21' 15.02" W -112.35417222° LONGITUDE (NAD83): MARICOPA COUNTY COUNTY: ZONING JURISDICTION: ZONING DISTRICT: ARIZONA PUBLIC SERVICE (APS) POWER COMPANY: TBD TELCO COMPANY: MONOPOLE T-1 COVER SHEET T-2 GENERAL NOTES AND SYMBOLS A-1 OVERALL SITE PLAN A-1.1 ENLARGED SITE & EQUIPMENT PLANS A-2 EXISTING ANTENNA PLANS & SCHEDULES A-3 EXISTING ELEVATIONS CONSTRUCTION TYPE: UTILITY OCCUPANCY TYPE: PROJECT SITE PROJECT MANAGER SITE ACQUISITION CONSTRUCTION MANAGER DATE SIGNATURE RF ENGINEER DEVELOPMENT MANAGER OPERATIONS REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED T-MOBILE / CONSULTANT SIGN OFF APPROVAL / SIGN OFF OF PRELIMINARY CONSTRUCTION DRAWINGS 501-52-003B PARCEL NUMBER: SBA AGENT: VIRTUAL SITE WALK LLC JAKE HAMILTON Jake@virtualsitewalk.com (619) 341-9208 RURAL-43 PART OF THE NORTH HALF OF THE NORTHWEST QUARTER OF SECTION 3, TOWN R NORTH, RANGE 1 WEST OF THE GILA AND SALT RIVER BASE AND MERIDIAN, COUNTRY, ARIZONA DESCRIBED AS FOLLOWS: BEGINNING AT A POINT ON THE NORTH LINE OF SAID SECTION, 1246 FEET EAST OF THE NORTHWEST CORNER THERE OF; THENCE SOUTH 23 FEET TO THE TRUE POINT OF BE GINNING; THENCE SOUTH 9 DEGREES 53 MINUTES 15 SECONDS EAST 110,64 FEET; THENCE SOUTH 22 FEET THENCE WEST 4 FEET THENCE NORTH 22 FEET THENCE WEST 31 FEET; THENCE SOUTH 2 DEGREES 57 MINUTES EAST 194,26 FEET THENCE EAST 362 FEET; THENCE NORTH 303 FEET TO A POINT 23 FEET SOUTH OF THE NORTH LINE OF SECTION; THENCE WEST 356 FEET TO THE TRUE POINT OF BEGINNING SUP LEGAL DESCRIPTION - (Z90-66A) A PORTION OF THE NORTHWEST QUARTER OF SECTION 5, TOWNSHIP 2 NORTH RANGE 1 WEST OF THE GILA AND SALT RIVER BASE AND MERIDIAN, MARICOPA COUNTY, ARIZONA, DESCRIBED AS FOLLOWS: BEGIN AT THE NORTHWEST CORNER OF SAID NORTHWEST QUARTER; THENCE NORTH 90 DEGREES 00 MINUTES 00 SECONDS EAST, ALONG THE NORTH LINE OF SAID NORTHWEST QUARTER, A DISTANCE OF 1465.26 FEET TO A POINT; THENCE SOUTH 00 DEGREES 00 MINUTES 00 SECONDS WEST, A DISTANCE OF 95.50 FEET TO THE TRUE POINT OF BEGINNING; THENCE SOUTH 89 DEGREES 51 MINUTES 15 SECONDS WEST, ALONG THE SOUTH FACE OF A MASONRY WALL AND THE EXTENSIONS THEREOF, A DISTANCE OF 40.53 FEET TO A POINT ON A BUILDING WALL; THENCE SOUTH 00 DEGREE 10 MINUTES 18 SECONDS EAST, ALONG SAID BUILDING WALL , A DISTANCE OF 16.00 FEET TO A POINT; THENCE DEPARTING SAID BUILDING WALL, NORTH 89 DEGREES 51 MINUTES 15 SECONDS EAST, A DISTANCE OF 40.52 FEET TO A POINT; THENCE NORTH 00 DEGREES 08 MINUTES 45 SECONDS WEST, A DISTANCE OF 16.00 FEET TO THE TRUE POINT OF BEGINNING. ALONG WITH ACCESS FROM THE ACCESS ENTRY POINT TO THE LEASE SITE. SUP LEGAL DESCRIPTION - (Z97-32) - THAT PORTION SITUATED IN MARICOPA COUNTY, ARIZONA DESCRIBED AS FOLLOWS; THAT PART OF THE NORTH HALF OF THE NORTHWEST QUARTER OF SECTION 3, TOWNSHIP 2 NORTH, RANGE 1 WEST OF THE GILA AND SALT RIVER BASE AND MERIDIAN, MARICOPA COUNTY, ARIZONA, COMMENCING AT A FOUND MONUMENT AT THE NORTHWEST CORNER OF SECTION 3, (THE INTERSECTION OF NORTHERN AVENUE AND LITCHFIELD ROAD); THENCE SOUTH 89 DEGREES 12 MINUTES 55 SECONDS EAST, A DISTANCE OF 1433,22 FEET; THENCE SOUTH 01 DEGREES 15 MINUTES 37 SECONDS WEST, A DISTANCE OF 79.98 FEET TO THE POINT OF BEGINNING; THENCE SOUTH 89 DEGREES 19 MINUTES 12 SECOND EAST, A DISTANCE OF 22.00 FEET; THENCE SOUTH 01 DEGREES 19 MINUTES 36 SECONDS WEST, A DISTANCE OF 15.00 FEET; THENCE NORTH 89 DEGREES 19 MINUTES 12 SECONDS WEST, A DISTANCE OF 22.00 FEET, THENCE NORTH 01 DEGREES 19 MINUTES 36 SECONDS EAST, A DISTANCE OF 15.00 FEET TO THE TRUE POINT OF BEGINNING. TOTAL SUP AREA: 986 SQ.FT. MARICOPA COUNTY PROJECT SITE AZ45116 13649 WEST NORTHERN AVE GLENDALE, AZ 85307 07/27/22 08/02/22 02/21/23 A 0 1 90% CUP REVIEW 100% FINAL CUP JURISDICTION COMMENTS NO. DATE REVISION DRAWN RA KM YK CONSULTANT: A&E CONSULTANT, SITE ACQUISITION AND PERMITTING: SHELIA GENERAL NOTES AND SYMBOLS T-2 THE EXISTING CONDITIONS REPRESENTED HEREIN ARE BASED ON VISUAL OBSERVATIONS AND INFORMATION PROVIDED BY OTHERS. ACOM CONSULTING CANNOT GUARANTEE THE CORRECTNESS NOR COMPLETENESS OF THE EXISTING CONDITIONS SHOWN AND ASSUMES NO RESPONSIBILITY THEREOF. CONTRACTOR AND HIS SUB-CONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS AS REQUIRED FOR PROPER EXECUTION OF PROJECT. REPORT ANY CONFLICTS OR DISCREPANCIES TO THE CONSULTANT PRIOR TO CONSTRUCTION. IMPORTANT NOTICE LEGEND LARGE SCALE DETAIL: BUILDING/WALL/DETAIL SECTION: REFERENCE: X X-X X X-X DETAIL NUMBER ELEVATION REFERENCE: X X-X X X-X SHEET NUMBER WHERE DETAILED DETAIL NUMBER REFERENCED DRAWING DETAIL NUMBER REFERENCED DRAWING REFERENCED DRAWING DETAIL NUMBER GENERAL NOTES 1. THE FACILITY IS AN UNOCCUPIED SPECIALIZED MOBILE RADIO FACILITY. 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A GRAPHIC REPRESENTATION OF THE FINAL INSTALLATION. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. 3. PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER. 4. THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING WORK. 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES, AND APPLICABLE REGULATIONS. 7. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING BEST SKILLS AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE PROJECT MANAGER AND WITH LANDLORD'S AUTHORIZED REPRESENTATIVE. 8. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC WITHIN 5 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION. 9. THE CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE, AND KEEP SAME ON SITE WHENEVER ANY PERSONNEL ARE ON SITE. 10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE WORK. 11. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK, REPAIR ANY DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF THE PROJECT MANAGER AND/OR LANDLORD. 12. ON A DAILY BASIS: KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH, AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY NATURE. 13. CONTRACTOR TO PROVIDE COMPLETE SET OF AS-BUILT DRAWINGS WITHIN 10 WORKING DAYS OF PROJECT COMPLETION. 14 WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 15. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION. 16 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF THIS WORK. 17. ALL ITEMS REMOVED OR DAMAGED DURING CONSTRUCTION WORK WILL BE REPLACED OR REPAIRED TO MATCH EXISTING. 18. ALL ELEMENTS OF EXISTING STRUCTURE TO REMAIN UNDISTURBED, UNLESS NOTED OTHERWISE. EXISTING STRUCTURE IS ASSUMED TO BE IN GOOD CONDITION, FREE OF DAMAGE OR DETERIORATION. CONTRACTOR TO VERIFY ALL ELEMENTS OF EXISTING STRUCTURE AFFECTED BY THIS MODIFICATION AND NOTIFY ENGINEER OF RECORD IF ANY DAMAGE, DETERIORATION OR DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THOSE DEPICTED ON THESE CONSTRUCTION DRAWINGS ARE FOUND. SPECIAL INSPECTION 1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL INSPECTOR UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. THE INDEPENDENT SPECIAL INSPECTOR SHALL COMPLY WITH ALL CITY SPECIAL INSPECTION REQUIREMENTS. 2. THE SPECIAL INSPECTOR SHALL PROVIDE A COPY OF THEIR REPORT TO THE OWNER, ARCHITECT, STRUCTURAL ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL AS EACH TEST IS COMPLETED. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION; THEN, IF UNCORRECTED, TO THE PROPER DESIGN AUTHORITY AND THE BUILDING OFFICIAL. 3. ANY MATERIAL WHICH FAILS TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER. SPECIAL INSPECTION TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS. 4. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS FOR THE MATERIAL USED IF THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE OF COMPLIANCE. 5. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT SIGNED BY BOTH HE AND HIS SUPERVISOR STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS IN CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE. STRUCTURAL NOTES 1. WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. 2. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES. 3. NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN SLABS, BEAMS, OR WALLS UNLESS SPECIFICALLY SHOWN OR NOTED, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, DUCTS, ETC., UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC. 4. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY AND HOLD T-MOBILE AND THE ARCHITECT/ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF T-MOBILE OR THE ARCHITECT/ENGINEER. STANDARD STRUCTURAL STEEL NOTES: 1. ALL METAL WORK SHALL BE IN ACCORDANCE WITH THE SPECIFICATION GALVANIZED ASTM A123-A123M-02 UNLESS NOTED OTHERWISE. 2. STRUCTURAL TUBING MEMBERS SHALL CONFORM TO ASTM A500, GRADE B. 3. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC AND AWS D1.1 WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION", 14TH EDITION. 4. BOLTED CONNECTIONS SHALL USE BEARING TYPE GALV. ASTM A325 BOLTS (5/8" DIA. UNO) AND SHALL HAVE A MINIMUM OF TWO BOLTS U.N.O AND SHALL INCLUDE HEAVY-HEX NUTS AND STANDARD CUT WASHERS. 5. NON-STRUCTURAL CONNECTIONS FOR HANDRAIL, LADDERS AND STEEL GRATING MAY USE 5/8" DIA GALVANIZED ASTM A307 BOLTS U.N.O. 6. ALL STRUCTURAL PIPE ASTM A53, TYPE E OR S, GRADE B. SPECIAL INSPECTION: 1. IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL INSPECTOR PER CODE FOR THE FOLLOWING ITEMS: A. CONTINUOUS DURING THE INSTALLATION OF EXPANSION AND/OR ADHESIVE ANCHORS, IF UTILIZED: INSPECT HOLE SIZE, DEPTH, CLEANLINESS, AND INSTALLATION PER ICC REPORT. B. PERIODIC FOR HIGH STRENGTH BOLT INSTALLATIONS (A325), IF UTILIZED. 5. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKERS, AND PEDESTRIANS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS DUE TO CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES, AND PARTIALLY COMPLETED WORK, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT/ENGINEER SHALL NOT INCLUDE INSPECTION OF SUCH ITEMS. 6. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION. 7. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR ROOF. LOAD SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE SHORING/BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH. 8. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION OF THIS WORK. 9. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. 10. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS. 11. ALL ITEMS REMOVED DURING CONSTRUCTION WORK (I.E., DRYWALL, PLYWOOD, CEILING PANELS, ETC.) SHALL BE REPLACED TO MATCH EXISTING. NORTH AZ45116 13649 WEST NORTHERN AVE GLENDALE, AZ 85307 07/27/22 08/02/22 02/21/23 A 0 1 90% CUP REVIEW 100% FINAL CUP JURISDICTION COMMENTS NO. DATE REVISION DRAWN RA KM YK CONSULTANT: A&E CONSULTANT, SITE ACQUISITION AND PERMITTING: SHELIA 1 OVERALL SITE PLAN 20' 10' 0" 20' 22"x34" SCALE: 1" = 20'-0" 11"x17" SCALE: 1" = 40'-0" NORTHERN AVE EXISTING INGRESS / EGRESS FROM NORTHERN AVE EXISTING SBA EQUIPMENT COMPOUND AND TOWER OVERALL SITE PLAN A-1 CONCRETE ACCESS ROAD EXISTING EMPTY LOT 2 A-3 1 A-3 EXISTING CHAINLINK FENCE EXISTING PARENT PROPERTY LINE 65'-0" R.O.W. EASEMENT 7'-0" ROADWAY & DITCH EASEMENT EXISTING AT&T 14'-4" X 23'-4" SHELTER EXISTING EMPTY CONCRETE PADS EXISTING 6'-0" HIGH CMU BLOCK WALL EXISTING PARENT PROPERTY LINE 66'-10" 236'-4" EXISTING COMPOUND 153'-4" 188'-10" THIS MCP IS ONLY FOR MONOPOLE AREA AND THE REST OF THE SITE IS NOT PART OF THIS REQUEST AZ45116 13649 WEST NORTHERN AVE GLENDALE, AZ 85307 07/27/22 08/02/22 02/21/23 A 0 1 90% CUP REVIEW 100% FINAL CUP JURISDICTION COMMENTS NO. DATE REVISION DRAWN RA KM YK CONSULTANT: A&E CONSULTANT, SITE ACQUISITION AND PERMITTING: SHELIA 1 2' 1' 0" 2' 22"x34" SCALE: 1/2" = 1'-0" 11"x17" SCALE: 1/4" = 1'-0" EXISTING ENLARGED EQUIPMENT PLAN A-1.1 ENLARGED SITE & EQUIPMENT PLANS 47'-4" (E) AT&T LEASE AREA 16'-0" (E) AT&T LEASE AREA NOTE: ALL EXISTING EQUIPMENT SHALL REMAIN. NO CHANGES ARE PROPOSED AT THIS TIME. NORTH EXISTING ACCESS GATE 14'-4" 23'-6" 26'-1" 18'-6" EXISTING 110'-0" SBA MONOPOLE EXISTING 7'-0" CHAINLINK FENCE EXISTING 9'-0" X 18'-0" TECH PARKING EXISTING 6'-0" HIGH CMU BLOCK WALL EXISTING COMPOUND EXISTING 14'-4" x 23'-6" AT&T SHELTER AZ45116 13649 WEST NORTHERN AVE GLENDALE, AZ 85307 07/27/22 08/02/22 02/21/23 A 0 1 90% CUP REVIEW 100% FINAL CUP JURISDICTION COMMENTS NO. DATE REVISION DRAWN RA KM YK CONSULTANT: A&E CONSULTANT, SITE ACQUISITION AND PERMITTING: SHELIA NORTH A-2 22"x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE 1 EXISTING ANTENNA SCHEDULE ANTENNA PLANS & SCHEDULES 2 EXISTING ANTENNA PLAN 22"x34" SCALE: NOT TO SCALE 11"x17" SCALE: NOT TO SCALE NOTE: ALL EXISTING EQUIPMENT SHALL REMAIN. NO CHANGES ARE PROPOSED AT THIS TIME. 80010766K EXISTING AT&T ANTENNA AND ANCILLARY EQUIPMENT SCHEDULE CABLE TYPE TMA / RAYCAP / DIPLEXER MODEL ANTENNA MODEL RAD CENTER AZIMUTH ALPHA SECTOR CABLE LENGTH JUMPER LENGTH RRH / RRU MODEL POSITION ACTIVE TECH. (REMAIN) 0° 98.00' 850 RRH(REMAIN) - FIBER (REMAIN) 1 (1) (1) - - 2 - 3 - - - - - EXISTING AT&T ANTENNAS AND ANCILLARY TO REMAIN CABLE TYPE TMA / RAYCAP / DIPLEXER MODEL ANTENNA MODEL RAD CENTER AZIMUTH CABLE LENGTH JUMPER LENGTH RRH / RRU MODEL POSITION ACTIVE TECH. CABLE TYPE TMA / RAYCAP / DIPLEXER MODEL ANTENNA MODEL RAD CENTER AZIMUTH CABLE LENGTH JUMPER LENGTH RRH / RRU MODEL POSITION ACTIVE TECH. BETA SECTOR GAMMA SECTOR - 4 - - - - - - - 1 - - 2 - 3 - - - - - - 4 - - - - - 1 - - 2 - 3 - - - - - - 4 - - - - - - - - EXISTING AT&T ANTENNA MOUNT EXISTING 110'-0" SBA MONOPOLE - - - - - 80010766K (REMAIN) 0° 98.00' 80010766K (REMAIN) 0° 98.00' 80010766K (REMAIN) 0° 98.00' 180' - - - - 850 RRH(REMAIN) FIBER (REMAIN) (1) (1) 180' 850 RRH(REMAIN) FIBER (REMAIN) (1) (1) 180' 80010766K (REMAIN) 120° 98.00' 80010766K (REMAIN) 98.00' 80010766K (REMAIN) 98.00' 80010766K (REMAIN) 98.00' 80010766K (REMAIN) 240° 98.00' 80010766K (REMAIN) 98.00' 80010766K (REMAIN) 98.00' 80010766K (REMAIN) 98.00' 120° 120° 120° 240° 240° 240° ±Ø1'-10" ±Ø17'-11" AZ45116 13649 WEST NORTHERN AVE GLENDALE, AZ 85307 07/27/22 08/02/22 02/21/23 A 0 1 90% CUP REVIEW 100% FINAL CUP JURISDICTION COMMENTS NO. DATE REVISION DRAWN RA KM YK CONSULTANT: A&E CONSULTANT, SITE ACQUISITION AND PERMITTING: SHELIA EXISTING ELEVATIONS A-3 EXISTING NORTH ELEVATION 2 22"x34" SCALE: 1/8" = 1'-0" 11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 0" 8' 2' NOTE: ALL EXISTING EQUIPMENT SHALL REMAIN. NO CHANGES ARE PROPOSED AT THIS TIME. EXISTING WEST ELEVATION 1 22"x34" SCALE: 1/8" = 1'-0" 11"x17" SCALE: 1/16" = 1'-0" 8' 6' 4' 0" 8' 2' EXISTING AT&T ANTENNA CENTERLINE 98.0' AGL EXISTING GRADE 0.0' AGL EXISTING TOP OF LIGHTNING ROD 112.6' AGL EXISTING TOP OF MONOPINE 110.0' AGL EXISTING AT&T ANTENNAS AND ANCILLARY EQUIPMENT EXISTING ANTENNA CENTERLINE 71.5' AGL EXISTING 7'-0" CHAINLINK FENCE EXISTING 6'-0" HIGH CMU BLOCK WALL EXISTING 14'-4" x 23'-6" AT&T SHELTER EXISTING ANTENNAS BY OTHERS EXISTING 110'-0" SBA MONOPOLE EXISTING AT&T ANTENNA CENTERLINE 98.0' AGL EXISTING GRADE 0.0' AGL EXISTING TOP OF LIGHTNING ROD 112.6' AGL EXISTING TOP OF MONOPINE 110.0' AGL EXISTING AT&T ANTENNAS AND ANCILLARY EQUIPMENT EXISTING ANTENNA CENTERLINE 71.5' AGL EXISTING 7'-0" CHAINLINK FENCE EXISTING 14'-4" x 23'-6" AT&T SHELTER EXISTING ANTENNAS BY OTHERS NOTE: ALL EXISTING EQUIPMENT SHALL REMAIN. NO CHANGES ARE PROPOSED AT THIS TIME. EXISTING 110'-0" SBA MONOPOLE EXISTING 6'-0" HIGH CMU BLOCK WALL Planning & Development 301 W. Jefferson St., Suite 170 Phoenix, Arizona 85003 Maricopa.gov ENGINEERING PLAN REVIEW COMMENTS Revised 2/1/23 Page 1 of 3 Date: February 3, 2023 Memo To: Darren Gerard, AICP, Deputy Director, Department of Planning & Development Attn: Paola Jaramillo Quintero, Planner, Planning & Development Services From: Jeri Loucks, P.E.C.F.M., Plans Examiner Engineer (Drainage), Planning & Development Services cc: Michael Norris, P.E., Drainage Engineering Manager, Planning & Development Subject: MCP2022009 – CUP RENEWAL (SBA 2012 TC Assets) Job Site Address: 13649 W Northern Ave, Glendale, Az 85307 APN(s): 501-52-003B Engineering Review has reviewed the first plan and report routed for review on 12/23/2022, for the subject application and has no objections. PND engineering plan review has no objections to the MCP. Please contact me if you have any questions or require any additional information. Planning & Development 301 W. Jefferson St., Suite 170 Phoenix, Arizona 85003 Maricopa.gov ENGINEERING PLAN REVIEW COMMENTS Revised 2/1/23 Page 2 of 3 DRAINAGE PLAN REVIEW REFERENCES: The Drainage Regulations are listed in Section 1205 of the MCZO: https://www.maricopa.gov/documentcenter/view/272 Maricopa County Drainage Policies and Standards Manual: https://www.maricopa.gov/DocumentCenter/Home/View/2369 For Additional Information See: https://www.maricopa.gov/1635/Drainage-Review FLOOD CONTROL DISTRICT OF MARICOPA COUNTY REFERENCES: Floodplain Regulations for Maricopa County: https://www.maricopa.gov/DocumentCenter/View/630 For Additional Information See: https://www.maricopa.gov/3847/Flood-Control-District MCDOT REFERENCES: Residential Driveway Guidelines https://www.maricopa.gov/documentcenter/view/362 Roadway Design Manual http://www.mcdot.maricopa.gov/DocumentCenter/View/24883 Maricopa County Ordinance for Work in R/W MCDOT Ordinance P36 For Additional Information See: https://www.maricopa.gov/156/MCDOT PND STORMWATER REFERENCES: Stormwater Quality Management and Discharge Control Regulation https://www.maricopa.gov/DocumentCenter/View/6577 Air Pollution Control Regulations Rule 310 https://www.maricopa.gov/DocumentCenter/View/5354 For Additional Information See: https://www.maricopa.gov/3980/Water-Sewage-Stormwater-Waste Planning & Development 301 W. Jefferson St., Suite 170 Phoenix, Arizona 85003 Maricopa.gov ENGINEERING PLAN REVIEW COMMENTS Revised 2/1/23 Page 3 of 3 Abbreviations Key: Drainage: DD = Department Directive (See: http://www.maricopa.gov/1911/Department-Directives) MCZO = Maricopa County Zoning Ordinance DPSM = Maricopa County Drainage Policies and Standards SSA = State Standard Attachment DDMV1= Maricopa County Drainage Design Manual – Hydrology DDMV2 = Maricopa County Drainage Design Manual – Hydraulics Flood Control: FRMC = Floodplain Regulations for Maricopa County PND Transportation: RDM = MCDOT Roadway Design Manual RDG = MCDOT Residential Design Guidelines MSRP = MCDOT Major Streets and Routes Plan Page | 1 Maricopa County Environmental Services Department Water and Waste Management The Maricopa County Environmental Services Department (MCESD) has completed review for the Sheila MCP without Plan of Development Wireless Telecommunications Facility planning case(s). Please note the following MCESD requirements for site development: Additional Notes – Environmental Services does not require these items for condition of approval of MCP2022009 , however these items must be addressed with the development of the site. Environmental Services does not require additional review of this case. *It should be noted that this document does not approve the referenced project. Comments are provided for the benefit of the applicant for MCESD permit requirements and as an advisory to Maricopa County Planning and Development Department. Other Maricopa County agencies may have additional requirements. Final review and approval will be made through Planning and Development Department procedures. Applicant may need to submit separate applications to the Maricopa County Environmental Services Department for approval of proposed facilities regulated by the Department. Review of any such application will be based on current regulations at the time of application. Project Name: Sheila MCP without Plan of Development Wireless Telecommunications Facility Primary Contact Name: Nicole Comach Planning Application Type: Military Compatibility Permit APN(s): 501-52-003A Reviewer: Souren Naradikian, P.E. Email: Souren.Naradikian@maricopa.gov Phone: 602-372-2907 Planner Name: Paola Jaramillo Planning Case #: MCP2022009 Date: January 24, 2023 Subdivision Infrastructure & Planning Program 301 W. Jefferson St. Phoenix, AZ 85003 Subdivision@maricopa.gov esd.maricopa.gov