05. MCP2022009 PZ Report

Maricopa County — Planning & Zoning (2023-04-20)

View PDF Item 5 Meeting page

Extracted text (via pymupdf) 37646 characters
MCP2022009 
Page 1 of 6 
 
 
Report to the Planning and Zoning Commission 
Prepared by the Maricopa County Planning and Development Department 
 
 
Case: 
MCP2022009 – Sheila AZ45116 
 
 
 
 
 
Hearing Date: 
April 20, 2023 
 
Supervisor District: 
4 
 
 
 
  
 
Applicant: 
Nicole Comach, Virtual Walk LLC 
 
Owner: 
13649 W. Northern LLC 
   
Request: 
Military Compatibility Permit (MCP) with a Plan of Development (POD) for 
a Wireless Communication Facility within the Rural-43 MAAMF zoning 
district. 
 
  
 
Site Location: 
Generally located on the SEC of Northern Avenue and Litchfield Rd. in the 
Glendale Area 
 
  
Site Size: 
Approx. 2.34 acres 
 
Density: 
N/A 
 
County Island:  
Yes, City of Glendale 
 
 
County Plan: 
White Tank Grand Avenue Area Plan – Military Compatible 
 
Municipal Plan: 
N/A 
 
Municipal Comments: 
None received to date  
 
Support/Opposition: 
None known 
 
Recommendation: 
Approve with conditions

MCP2022009 
Page 2 of 6 
Project Summary: 
 
1. 
The applicant, Nicole Comach on behalf of Vertical Site Walk LLC, is requesting a Military 
Compatibility Permit (MCP) with a Plan of Development (POD) to allow an existing wireless 
communication facility on 986 sq. ft. of the 2.34-acre site located northeast of Luke Air Force 
Base (LAFB). The wireless communication facility consists of a 110’ monopole and a 339 sq. ft.  
AT&T Shelter. The existing tower was previously approved under Special Use Permit Case Z97-
32, but expired October 2022. The applicant is not proposing any changes to the existing tower. 
 
2. 
The site is within the City of Glendale’s municipal planning area. The Glendale General Plan 
Designates the property as Luke Compatible, which is applied to lands surrounding LAFB. 
Similarly, the county’s area plan designates the general area for Military Compatible land uses. 
This designation coincides with the Military Airbase and Ancillary Military Facility Overlay Zoning 
District (MAAMF). A portion of the lot on the northwest corner is within the clear zone meant to 
prevent development that would encroach on LAFB’s runways. Projects located within the 
MAAMF must first obtain a Use Compatibility and Consistency Determination (UCCD) prior to 
being able to apply for a Military Compatibility Permit (MCP). LAFB determined that this proposed 
cell tower use is consistent and compatible with the high noise or accident potential zone per 
UC2022022. 
 
3. 
The earliest available aerial photography of the site from 1949 indicates it as farmland directly 
bordering LAFB to the southwest. In 1997 the subject site was developed with a wireless 
communications facility. Additionally, a separate parcel to the south, 501-52-005L, will be 
developed as a warehouse complex and is not part of the subject entitlement. The applicant filed 
and was approved for a UCCD from LAFB, UC2022022, in November of 2022. The applicant 
applied for the subject MCP with POD in December of 2022.  
 
 
2022 Site Aerial

MCP2022009 
Page 3 of 6 
Rural – 43 Military Airport and Ancillary Military Facility Overlay District & Surrounding Districts 
 
 
 
Existing Site Plan

MCP2022009 
Page 4 of 6 
Existing Elevations 
 
 
 
Existing On-Site and Adjacent Zoning / Land Use: 
 
4. 
On-site: 
 
Rural-43 MAAMF / Wireless Communication Facility 
North: 
Northern Avenue then Rural-43 MAAMF / Agriculture Land 
South: 
IND-2 MAAMF / Vacant Land 
East: 
IND-2 MAAMF / Vacant Land 
West: 
IND-2 MAAMF / Vacant Land 
 
Utilities and Services: 
 
5. 
Water: 
 
Valley Utilities 
Wastewater: 
Liberty Water 
School District: 
Dysart Unified School District 
Fire: 
Rural Metro 
Police:  
MCSO 
 
Right-of-Way: 
 
6. 
The following table includes existing and proposed half-width right-of-way and the future 
classification based upon the Maricopa County Department of Transportation (MCDOT) Major 
Streets and Routes Plan. Litchfield Rd is under the City of Glendale’s jurisdiction. 
 
Street Name 
Half-width Existing R/W 
Half-width Proposed R/W 
Future Classification 
Northern Ave. 
33’ 
N/A 
Urban Minor Arterial 
 
Adopted Plans: 
 
 
7. 
White Tank/Grand Avenue Area Plan (Revised: 2020): This plan identifies the subject parcel as 
Military Compatible Land Use Area. Luke Air Force Base muse issue a Use Consistency and 
Compatibility Determination (UCCD) prior to a use being allowed in this area.

MCP2022009 
Page 5 of 6 
8. 
City of Glendale General Plan (Revised 2016): This plan identifies the subject parcel as a Luke 
Compatible Land Use Area.  
 
 
Public Participation Summary: 
 
9. 
The applicant complied with the Maricopa County Public Participation Process with the required 
posting of the property and the notification to the adjacent property owners within 300’ of the 
subject site. Staff has not received any notice of opposition or support to the request. LAFB sent 
staff comments stating the request will not negatively impact flying operations at the base.  
 
Outstanding Concerns from Reviewing Agencies: 
 
10. 
N/A. 
 
Staff Analysis: 
 
11. 
The Military Airport and Ancillary Military Facility Overlay became effective in 2008, after the 
existing wireless communication facility use was established in 1997. Staff believes that the 
continuation use of the Wireless Communication Facility is appropriate for the site as it will 
remain as is. LAFB found that the existing land use is consistent and compatible with the High 
Noise and Accident Potential Zone of the base, and that it would not negatively impact flying 
operations. As such, Maricopa County can make a similar determination of compatibility and 
consistency.  
 
Recommendation: 
 
12. 
For the reasons outlined in this report, staff recommends the Commission adopt a motion 
recommending that the Board of Supervisors approve MCP2022009, subject to the following 
conditions ‘a’ – ‘g’: 
 
a. 
Development of the site shall be in substantial conformance with the Site Plan entitled 
“Military Compatibility Permit”, consisting of 6 pages, dated February 2, 2023, except as 
modified by the following conditions.  
 
b. 
Development of the site shall be in substantial conformance with the Narrative Report 
entitled “Shelia/AZ45116 Narrative Report”, consisting of 3 pages, dated February 20, 
2023, except as modified by the following conditions. 
 
c. 
Major amendments to the site plan will require a new UCCD and MCP application to be 
filed prior to any permit approvals. The incorporation of any other parcels into this project 
will require a lot combination, new UCCD, and new MCP prior to any additional permit 
approvals.  
 
d. 
The height of the wireless communication facility shall be limited to 110 feet. 
 
e. 
The property owner/s and their successors waive claim for diminution in value if the 
County takes action to rescind approval due to noncompliance with conditions.

MCP2022009 
Page 6 of 6 
f. 
Noncompliance with any Maricopa County regulation shall be grounds for initiating 
revocation of this Military Compatibility Permit as set forth in the Maricopa County Zoning 
Ordinance. 
 
g. 
The granting of this change in use of the property has been at the request of the applicant, 
with consent of the landowner. The granting of this approval allows the property to enjoy 
uses in excess of those permitted by the zoning existing on the date of application, subject 
to conditions. In the event of the failure to comply with any condition, the property shall 
revert to the zoning that existed on the date of application. It is, therefore, stipulated and 
agreed that either revocation due to the failure to comply with any conditions, does not 
reduce any rights that existed on the date of application to use, divide, sell or possess the 
property and that there would be no diminution in value of the property from the value it 
held on the date of application due to such revocation of the MCP. The MCP enhances the 
value of the property above its value as of the date the MCP is granted and reverting to 
the prior zoning results in the same value of the property as if the MCP had never been 
granted.  
 
Presented by: 
Paola Jaramillo, Planner 
Reviewed by: 
Darren Gerard, AICP, Planning Supervisor 
 
Attachments: 
Case Map (1 page) 
 
Application (1 page) 
 
Narrative Report (6 pages) 
 
Site Plan (6 pages) 
 
Engineering comments (2 pages) 
 
MCESD comments (1 page)

/
Maricopa County Planning & Development - Phoenix, AZ
4
Gross Acres: 1 approx.
Generated March 30, 2023 11:21 AM
MCP2022009
Application Name:
Legal Description
Sheila AZ45116
Applicant
Case Address
T02N R01W 3,
NICOLE COMACH for VIRTUAL SITE WALK, LLC
13649 W NORTHERN Ave
Applicant Phone/Email
Parcel Primary:501-52-003A
541.228.4823
NICOLE@VIRTUALSITEWALK.COM
GLENDALE AZ 85307
Map scale 1:917
Supervisor District No.
SHELIA/AZ 45116
5.3585 in

2/28/2023

February 20, 2023 
 
NARRATIVE REPORT 
 
 
PREVIOUS PERMIT#: Case No.: Z97-32 
CURRENT CASE #: MCP2022009 
SITE NAME: Shelia/AZ45116 
SITE ADDRESS: 13649 W. Northern Ave., Glendale, AZ 85023 
APN: 501-52-003B

B: Purpose of Request 
SBA 2012 TC Assets, LLC, herein referenced as the Applicant, is requesting the Military 
Compatibility Permit to continue the use of an existing Wireless Telecommunications Facility 
that was approved under Z97-32 but has expired. The applicant proposes no alteration to its 
existing Wireless Telecommunications Facility located at the address above. 
C: Description of Proposal 
This is an existing Wireless Telecommunications Facility. There is no proposed construction, 
modifications, or height increase at this time.  We propose to continue the use of the facility. 
The Monopole exists at 110-feet in height, with the top of the lightning rod at 112-feet. The 
tower consists of panel antennas, all with the New Cingular Wireless carrier. The equipment 
compound is located on the ground directly next to the monopole. Both the tower and 
equipment are behind a fence with 24-hour locked access 
D: Relationship to Surrounding Properties 
Our subject parcel is in a Rural (R-43) zone. Surrounding parcels are mostly zoned Industrial 
(IND-2). This site provides continued telecommunications coverage to the community, including 
enhanced emergency response, better reception quality and higher security and privacy for 
telephone users. The project continues to fit the intended goals because it would reduce risk of 
injury or death through enhanced cellular phone service, would promote efficiency of public 
services through enhanced cellular phone service, and does not generate a large amount of 
traffic, noise, congestion or odors. This project does not increase visual blight in the 
surrounding area because the applicant proposes no changes to the existing site.  
E: Location and Accessibility 
The facility is located at 13649 W. Northern Ave., Glendale, AZ 85023; APN: 501-52-003A. The 
equipment compound is located on the ground directly next to the monopole. Both the tower 
and equipment are behind a fence with 24-hour locked access. To secure the wireless facility 
from access by all persons other than authorized personnel, there will continue to be locked 
access where the equipment is located.  
F: Relationship to State Statute 
The facility is a Monopole and this department approved the project as constructed, and 
implemented Conditions of Approval to ensure that it was completed using the least intrusive 
means necessary. Because there are no changes to the existing site, the use will not be contrary 
to the character or performance standards established for Maricopa County, in which it is 
located. A Noise Study is available upon request. 
G: Circulation System

N/A as there are no proposed modifications or construction. 
H: Development Schedule 
N/A as there are no proposed modifications or construction. 
I: Community Facilities and Services 
Our subject parcel is in a Rural (R-43) zone. Surrounding parcels are mostly zoned Industrial 
(IND-2). 
J: Public Utilities and Services 
The applicant is not proposing any change in the use or technology with this application. The 
facility does not require the use of public services. 
K: Other Helpful Information 
No new co-location issues exist since this is a request for the continued use of an existing 
wireless facility only. The Applicant agrees to continue complying with all cosmetic and other 
maintenance requirements. Along with the Military Compatibility Permit Application for 
renewing the Conditional Use Permit for this facility, the applicant is submitting Site Plans 
showing what the tower looks like currently. The applicant is not proposing any change in the 
use or technology with this application.  
 
Thank you for your consideration.

V-B
SBA 2012 TC ASSETS, LLC
8051 CONGRESS AVE
BOCA RATON, FL 33487
APPLICANT:
DRAWING INDEX
AZ45116
13649 WEST NORTHERN AVE
GLENDALE, AZ 85307
07/27/22
08/02/22
02/21/23
A
0
1
90% CUP REVIEW
100% FINAL CUP
JURISDICTION COMMENTS
NO.
DATE
REVISION
DRAWN
RA
KM
YK
CONSULTANT:
A&E CONSULTANT, SITE ACQUISITION AND PERMITTING:
SHELIA
NOTE:
THE PURPOSE OF THIS PROJECT IS THE REQUEST A MILITARY
COMPATIBILITY PERMIT FOR THE CONTINUATION USE OF THE
MONOPOLE ON THE SITE.
13649 W NORTHERN LLC
1545 W EL CAMINITO DR
PHOENIX AZ, 85021
PROPERTY OWNER:
COVER SHEET
T-1
PROJECT CONTACT LIST
AREA MAP
LEGAL DESCRIPTION
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS
AND ADVISE CONSULTANTS OF ANY ERRORS OR OMISSIONS. NO
VARIATIONS OR MODIFICATIONS TO WORK SHOWN SHALL BE IMPLEMENTED
WITHOUT PRIOR WRITTEN APPROVAL. ALL PREVIOUS ISSUES OF THIS
DRAWING ARE SUPERSEDED BY THE LATEST REVISION. ALL DRAWINGS
AND SPECIFICATIONS REMAIN THE PROPERTY OF ACOM CONSULTING.
THESE DOCUMENTS ARE CONFIDENTIAL AND ARE THE SOLE PROPERTY OF
T-MOBILE AND MAY NOT BE REPRODUCED, DISSEMINATED OR
REDISTRIBUTED WITHOUT THE EXPRESS WRITTEN CONSENT OF T-MOBILE.
SCOPE OF WORK
NORTH
LOCATION MAP
NORTH
PROJECT:
MILITARY COMPATIBILITY PERMIT
CASE NUMBER:
MCP2022009
SITE NAME: 
SHELIA
SBA SITE NUMBER: 
AZ45116
SITE ADDRESS:
13649 WEST NORTHERN AVE
GLENDALE, AZ 85307
SITE TYPE:
N 33° 33' 03.66"
N 33.55101667°
LATITUDE (NAD83):
W -112° 21' 15.02"
W -112.35417222°
LONGITUDE (NAD83):
MARICOPA COUNTY
COUNTY:
ZONING JURISDICTION:
ZONING DISTRICT:
ARIZONA PUBLIC SERVICE (APS)
POWER COMPANY:
TBD
TELCO COMPANY:
MONOPOLE
T-1 
COVER SHEET
T-2 
GENERAL NOTES AND SYMBOLS
A-1 
OVERALL SITE PLAN
A-1.1 
ENLARGED SITE & EQUIPMENT PLANS
A-2 
EXISTING ANTENNA PLANS & SCHEDULES
A-3 
EXISTING ELEVATIONS
CONSTRUCTION TYPE:
UTILITY
OCCUPANCY TYPE:
PROJECT SITE
PROJECT MANAGER
SITE ACQUISITION
CONSTRUCTION MANAGER
DATE
SIGNATURE
RF ENGINEER
DEVELOPMENT MANAGER
OPERATIONS
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
T-MOBILE / CONSULTANT SIGN OFF
APPROVAL / SIGN OFF OF PRELIMINARY
CONSTRUCTION DRAWINGS
501-52-003B
PARCEL NUMBER:
SBA AGENT:
VIRTUAL SITE WALK LLC
JAKE HAMILTON
Jake@virtualsitewalk.com
(619) 341-9208
RURAL-43
PART OF THE NORTH HALF OF THE NORTHWEST QUARTER OF SECTION 3,
TOWN R NORTH, RANGE 1 WEST OF THE GILA AND SALT RIVER BASE AND
MERIDIAN, COUNTRY, ARIZONA DESCRIBED AS FOLLOWS:
BEGINNING AT A POINT ON THE NORTH LINE OF SAID SECTION, 1246 FEET
EAST OF THE NORTHWEST CORNER THERE OF;
THENCE SOUTH 23 FEET TO THE TRUE POINT OF BE GINNING;
THENCE SOUTH 9 DEGREES 53 MINUTES 15 SECONDS EAST 110,64 FEET;
THENCE SOUTH 22 FEET
THENCE WEST 4 FEET
THENCE NORTH 22 FEET
THENCE WEST 31 FEET;
THENCE SOUTH 2 DEGREES 57 MINUTES EAST 194,26 FEET
THENCE EAST 362 FEET;
THENCE NORTH 303 FEET TO A POINT 23 FEET SOUTH OF THE NORTH LINE OF
SECTION;
THENCE WEST 356 FEET TO THE TRUE POINT OF BEGINNING
SUP LEGAL DESCRIPTION - (Z90-66A)
A PORTION OF THE NORTHWEST QUARTER OF SECTION 5, TOWNSHIP 2
NORTH RANGE 1 WEST OF THE GILA AND SALT RIVER BASE AND MERIDIAN,
MARICOPA COUNTY, ARIZONA, DESCRIBED AS FOLLOWS:
BEGIN AT THE NORTHWEST CORNER OF SAID NORTHWEST QUARTER;
THENCE NORTH 90 DEGREES 00 MINUTES 00 SECONDS EAST, ALONG THE
NORTH LINE OF SAID NORTHWEST QUARTER, A DISTANCE OF 1465.26 FEET
TO A POINT;
THENCE SOUTH 00 DEGREES 00 MINUTES 00 SECONDS WEST, A DISTANCE OF
95.50 FEET TO THE TRUE POINT OF BEGINNING;
THENCE SOUTH 89 DEGREES 51 MINUTES 15 SECONDS WEST, ALONG THE
SOUTH FACE OF A MASONRY WALL AND THE EXTENSIONS THEREOF, A
DISTANCE OF 40.53 FEET TO A POINT ON A BUILDING WALL;
THENCE SOUTH 00 DEGREE 10 MINUTES 18 SECONDS EAST, ALONG SAID
BUILDING WALL , A DISTANCE OF 16.00 FEET TO A POINT;
THENCE DEPARTING SAID BUILDING WALL, NORTH 89 DEGREES 51 MINUTES
15 SECONDS EAST, A DISTANCE OF 40.52 FEET TO A POINT;
THENCE NORTH 00 DEGREES 08 MINUTES 45 SECONDS WEST, A DISTANCE OF
16.00 FEET TO THE TRUE POINT OF BEGINNING.
ALONG WITH ACCESS FROM THE ACCESS ENTRY POINT TO THE LEASE SITE.
SUP LEGAL DESCRIPTION - (Z97-32) - THAT PORTION SITUATED IN MARICOPA
COUNTY, ARIZONA DESCRIBED AS FOLLOWS; THAT PART OF THE NORTH
HALF OF THE NORTHWEST QUARTER OF SECTION 3, TOWNSHIP 2 NORTH,
RANGE 1 WEST OF THE GILA AND SALT RIVER BASE AND MERIDIAN,
MARICOPA COUNTY, ARIZONA, COMMENCING AT A FOUND MONUMENT AT
THE NORTHWEST CORNER OF SECTION 3, (THE INTERSECTION OF
NORTHERN AVENUE AND LITCHFIELD ROAD); THENCE SOUTH 89 DEGREES 12
MINUTES 55 SECONDS EAST, A DISTANCE OF 1433,22 FEET; THENCE SOUTH 01
DEGREES 15 MINUTES 37 SECONDS WEST, A DISTANCE OF 79.98 FEET TO THE
POINT OF BEGINNING; THENCE SOUTH 89 DEGREES 19 MINUTES 12 SECOND
EAST, A DISTANCE OF 22.00 FEET; THENCE SOUTH 01 DEGREES 19 MINUTES
36 SECONDS WEST, A DISTANCE OF 15.00 FEET; THENCE NORTH 89 DEGREES
19 MINUTES 12 SECONDS WEST, A DISTANCE OF 22.00 FEET, THENCE NORTH
01 DEGREES 19 MINUTES 36 SECONDS EAST, A DISTANCE OF 15.00 FEET TO
THE TRUE POINT OF BEGINNING.
TOTAL SUP AREA: 986 SQ.FT.
MARICOPA COUNTY
PROJECT SITE

AZ45116
13649 WEST NORTHERN AVE
GLENDALE, AZ 85307
07/27/22
08/02/22
02/21/23
A
0
1
90% CUP REVIEW
100% FINAL CUP
JURISDICTION COMMENTS
NO.
DATE
REVISION
DRAWN
RA
KM
YK
CONSULTANT:
A&E CONSULTANT, SITE ACQUISITION AND PERMITTING:
SHELIA
GENERAL NOTES
AND SYMBOLS
T-2
THE EXISTING CONDITIONS REPRESENTED HEREIN ARE BASED ON VISUAL OBSERVATIONS AND
INFORMATION PROVIDED BY OTHERS. ACOM CONSULTING CANNOT GUARANTEE THE CORRECTNESS NOR
COMPLETENESS OF THE EXISTING CONDITIONS SHOWN AND ASSUMES NO RESPONSIBILITY THEREOF.
CONTRACTOR AND HIS SUB-CONTRACTORS SHALL VISIT THE SITE AND VERIFY ALL EXISTING CONDITIONS
AS REQUIRED FOR PROPER EXECUTION OF PROJECT. REPORT ANY CONFLICTS OR DISCREPANCIES TO
THE CONSULTANT PRIOR TO CONSTRUCTION.
IMPORTANT NOTICE
LEGEND
LARGE SCALE DETAIL:
BUILDING/WALL/DETAIL SECTION:
REFERENCE:
X
X-X
X
X-X
DETAIL NUMBER
ELEVATION REFERENCE:
X
X-X
X
X-X
SHEET NUMBER
WHERE DETAILED
DETAIL NUMBER
REFERENCED
DRAWING
DETAIL NUMBER
REFERENCED
DRAWING
REFERENCED
DRAWING
DETAIL NUMBER
GENERAL NOTES
1.
THE FACILITY IS AN UNOCCUPIED SPECIALIZED MOBILE RADIO FACILITY.
2.
PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A GRAPHIC REPRESENTATION OF THE
FINAL INSTALLATION. THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT,
APPURTENANCES AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON
THE DRAWINGS.
3.
PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR SHALL VISIT THE JOB SITE AND BE
RESPONSIBLE FOR ALL CONTRACT DOCUMENTS, FIELD CONDITIONS, AND DIMENSIONS AND
CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH
CONSTRUCTION. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE PROJECT
MANAGER.
4.
THE CONTRACTOR SHALL RECEIVE, IN WRITING, AUTHORIZATION TO PROCEED BEFORE STARTING
WORK.
5.
THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE
LOCAL CODES OR REGULATIONS TAKE PRECEDENCE.
6.
ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH
APPLICABLE CODES, REGULATIONS, AND ORDINANCES. CONTRACTOR SHALL GIVE ALL NOTICES
AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY
PUBLIC AUTHORITY BEARING ON THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL
SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY
COMPANY SPECIFICATIONS AND LOCAL AND STATE JURISDICTIONAL CODES, ORDINANCES, AND
APPLICABLE REGULATIONS.
7.
THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING BEST SKILLS AND ATTENTION.
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE
WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE PROJECT
MANAGER AND WITH LANDLORD'S AUTHORIZED REPRESENTATIVE.
8.
PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC
WITHIN 5 FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING
CONSTRUCTION.
9.
THE CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE, AND KEEP SAME ON
SITE WHENEVER ANY PERSONNEL ARE ON SITE.
10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN. MINOR MODIFICATIONS MAY BE
REQUIRED TO SUIT JOB DIMENSIONS OR CONDITIONS, AND SUCH MODIFICATIONS SHALL BE
INCLUDED AS PART OF THE WORK.
11.
THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS,
PAVING, CURBS, GALVANIZED SURFACES, ETC., AND UPON COMPLETION OF WORK, REPAIR ANY
DAMAGE THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF THE PROJECT
MANAGER AND/OR LANDLORD.
12.
ON A DAILY BASIS: KEEP GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS,
RUBBISH, AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY. LEAVE
PREMISES IN CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST OR SMUDGES OF ANY
NATURE.
13.
CONTRACTOR TO PROVIDE COMPLETE SET OF AS-BUILT DRAWINGS WITHIN 10 WORKING DAYS OF
PROJECT COMPLETION.
14
WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS
FOR OTHER SIMILAR WORK.
15.
ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION.
16
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES
WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR
SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE EXECUTION OF
THIS WORK.
17.
ALL ITEMS REMOVED OR DAMAGED DURING CONSTRUCTION WORK WILL BE REPLACED OR
REPAIRED TO MATCH EXISTING.
18.
ALL ELEMENTS OF EXISTING STRUCTURE TO REMAIN UNDISTURBED, UNLESS NOTED OTHERWISE.
EXISTING STRUCTURE IS ASSUMED TO BE IN GOOD CONDITION, FREE OF DAMAGE OR
DETERIORATION. CONTRACTOR TO VERIFY ALL ELEMENTS OF EXISTING STRUCTURE AFFECTED BY
THIS MODIFICATION AND NOTIFY ENGINEER OF RECORD IF ANY DAMAGE, DETERIORATION OR
DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THOSE DEPICTED ON THESE CONSTRUCTION
DRAWINGS ARE FOUND.
SPECIAL INSPECTION
1.
IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL INSPECTOR
UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER. THE INDEPENDENT SPECIAL
INSPECTOR SHALL COMPLY WITH ALL CITY SPECIAL INSPECTION REQUIREMENTS.
2.
THE SPECIAL INSPECTOR SHALL PROVIDE A COPY OF THEIR REPORT TO THE OWNER, ARCHITECT,
STRUCTURAL ENGINEER, CONTRACTOR, AND BUILDING OFFICIAL AS EACH TEST IS COMPLETED. ALL
DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR
CORRECTION; THEN, IF UNCORRECTED, TO THE PROPER DESIGN AUTHORITY AND THE BUILDING OFFICIAL.
3.
ANY MATERIAL WHICH FAILS TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER. SPECIAL INSPECTION TESTING
REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS.
4.
INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS FOR THE MATERIAL USED IF
THE CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING
PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE
OF COMPLIANCE.
5.
THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT SIGNED BY BOTH HE AND HIS SUPERVISOR
STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS IN CONFORMANCE WITH THE
APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE.
STRUCTURAL NOTES
1.
WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED, THE DETAIL SHALL BE THE SAME AS
FOR OTHER SIMILAR WORK.
2.
NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES.
3.
NO PIPES, DUCTS, SLEEVES, CHASES, ETC., SHALL BE PLACED IN SLABS, BEAMS, OR WALLS UNLESS
SPECIFICALLY SHOWN OR NOTED, NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES,
DUCTS, ETC., UNLESS OTHERWISE NOTED. CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR
INSTALLATION OF ANY ADDITIONAL PIPES, DUCTS, ETC.
4.
CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB
SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY OF
ALL PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND, INDEMNIFY
AND HOLD T-MOBILE AND THE ARCHITECT/ENGINEER HARMLESS FROM ANY AND ALL LIABILITY, REAL
OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT, EXCEPTING
FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF T-MOBILE  OR THE ARCHITECT/ENGINEER.
STANDARD STRUCTURAL STEEL NOTES:
1.
ALL METAL WORK SHALL BE IN ACCORDANCE WITH THE SPECIFICATION GALVANIZED ASTM
A123-A123M-02 UNLESS NOTED OTHERWISE.
2.
STRUCTURAL TUBING MEMBERS SHALL CONFORM TO ASTM A500, GRADE B.
3.
ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC
AND AWS D1.1 WHERE FILLET WELD SIZES ARE NOT SHOWN, PROVIDE THE MINIMUM SIZE PER TABLE
J2.4 IN THE AISC "MANUAL OF STEEL CONSTRUCTION", 14TH EDITION.
4.
BOLTED CONNECTIONS SHALL USE BEARING TYPE GALV. ASTM A325 BOLTS (5/8" DIA. UNO) AND
SHALL HAVE A MINIMUM OF TWO BOLTS U.N.O AND SHALL INCLUDE HEAVY-HEX NUTS AND
STANDARD CUT WASHERS.
5.
NON-STRUCTURAL CONNECTIONS FOR HANDRAIL, LADDERS AND STEEL GRATING MAY USE 5/8" DIA
GALVANIZED ASTM A307 BOLTS U.N.O.
6.
ALL STRUCTURAL PIPE ASTM A53, TYPE E OR S, GRADE B.
SPECIAL INSPECTION:
1.
IF REQUIRED, SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL
INSPECTOR PER CODE FOR THE FOLLOWING ITEMS:
A.
CONTINUOUS DURING THE INSTALLATION OF EXPANSION AND/OR ADHESIVE ANCHORS, IF UTILIZED:
INSPECT HOLE SIZE, DEPTH, CLEANLINESS, AND INSTALLATION PER ICC REPORT.
B.
PERIODIC FOR HIGH STRENGTH BOLT INSTALLATIONS (A325), IF UTILIZED.
5.
THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. THEY DO
NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES
NECESSARY TO PROTECT THE STRUCTURE, WORKERS, AND PEDESTRIANS DURING CONSTRUCTION.
SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING FOR LOADS DUE TO
CONSTRUCTION EQUIPMENT, TEMPORARY STRUCTURES, AND PARTIALLY COMPLETED WORK, ETC.
OBSERVATION VISITS TO THE SITE BY THE ARCHITECT/ENGINEER SHALL NOT INCLUDE INSPECTION
OF SUCH ITEMS.
6.
ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION.
7.
CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR ROOF. LOAD
SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT. PROVIDE ADEQUATE
SHORING/BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH.
8.
IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES 
WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR 
SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION
OF THIS WORK.
9.
DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS.
10.
THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS.
11.
ALL ITEMS REMOVED DURING CONSTRUCTION WORK (I.E., DRYWALL, PLYWOOD, CEILING PANELS,
ETC.) SHALL BE REPLACED TO MATCH EXISTING.

NORTH
AZ45116
13649 WEST NORTHERN AVE
GLENDALE, AZ 85307
07/27/22
08/02/22
02/21/23
A
0
1
90% CUP REVIEW
100% FINAL CUP
JURISDICTION COMMENTS
NO.
DATE
REVISION
DRAWN
RA
KM
YK
CONSULTANT:
A&E CONSULTANT, SITE ACQUISITION AND PERMITTING:
SHELIA
1
OVERALL SITE PLAN
20'
10'
0"
20'
22"x34" SCALE: 1" = 20'-0"
11"x17" SCALE: 1" = 40'-0"
NORTHERN AVE
EXISTING INGRESS / EGRESS
FROM NORTHERN AVE
EXISTING SBA EQUIPMENT
COMPOUND AND TOWER
OVERALL
SITE PLAN
A-1
CONCRETE ACCESS ROAD
EXISTING EMPTY LOT
2
A-3
1
A-3
EXISTING CHAINLINK FENCE
EXISTING PARENT
PROPERTY LINE
65'-0"
R.O.W. EASEMENT
7'-0"
ROADWAY & DITCH EASEMENT
EXISTING AT&T 14'-4" X 23'-4"
SHELTER
EXISTING EMPTY
CONCRETE PADS
EXISTING 6'-0" HIGH CMU
BLOCK WALL
EXISTING PARENT
PROPERTY LINE
66'-10"
236'-4"
EXISTING COMPOUND
153'-4"
188'-10"
THIS MCP IS ONLY FOR MONOPOLE
AREA AND THE REST OF THE SITE
IS NOT PART OF THIS REQUEST

AZ45116
13649 WEST NORTHERN AVE
GLENDALE, AZ 85307
07/27/22
08/02/22
02/21/23
A
0
1
90% CUP REVIEW
100% FINAL CUP
JURISDICTION COMMENTS
NO.
DATE
REVISION
DRAWN
RA
KM
YK
CONSULTANT:
A&E CONSULTANT, SITE ACQUISITION AND PERMITTING:
SHELIA
1
2'
1'
0"
2'
22"x34" SCALE: 1/2" = 1'-0"
11"x17" SCALE: 1/4" = 1'-0"
EXISTING ENLARGED EQUIPMENT PLAN
A-1.1
ENLARGED SITE  &
EQUIPMENT PLANS
47'-4" (E)  AT&T LEASE AREA
16'-0" (E) AT&T LEASE AREA
NOTE:
ALL EXISTING EQUIPMENT SHALL REMAIN. NO
CHANGES ARE PROPOSED AT THIS TIME.
NORTH
EXISTING ACCESS GATE
14'-4"
23'-6"
26'-1"
18'-6"
EXISTING 110'-0" SBA MONOPOLE
EXISTING 7'-0" CHAINLINK
FENCE
EXISTING 9'-0" X 18'-0"
TECH PARKING
EXISTING 6'-0" HIGH CMU
BLOCK WALL
EXISTING COMPOUND
EXISTING 14'-4" x 23'-6"
AT&T SHELTER

AZ45116
13649 WEST NORTHERN AVE
GLENDALE, AZ 85307
07/27/22
08/02/22
02/21/23
A
0
1
90% CUP REVIEW
100% FINAL CUP
JURISDICTION COMMENTS
NO.
DATE
REVISION
DRAWN
RA
KM
YK
CONSULTANT:
A&E CONSULTANT, SITE ACQUISITION AND PERMITTING:
SHELIA
NORTH
A-2
22"x34" SCALE: NOT TO SCALE
11"x17" SCALE: NOT TO SCALE
1
EXISTING ANTENNA SCHEDULE
ANTENNA PLANS &
SCHEDULES
2
EXISTING ANTENNA PLAN
22"x34" SCALE: NOT TO SCALE
11"x17" SCALE: NOT TO SCALE
NOTE:
ALL EXISTING EQUIPMENT SHALL REMAIN. NO
CHANGES ARE PROPOSED AT THIS TIME.
80010766K
EXISTING AT&T ANTENNA AND ANCILLARY EQUIPMENT SCHEDULE
CABLE TYPE
TMA / RAYCAP /
DIPLEXER MODEL
 ANTENNA MODEL
RAD CENTER
AZIMUTH
ALPHA SECTOR
CABLE
LENGTH
JUMPER
LENGTH
RRH / RRU MODEL
POSITION
ACTIVE
TECH.
(REMAIN)
0°
98.00'
850 RRH(REMAIN)
-
FIBER (REMAIN)
1
(1)
(1)
-
-
2
-
3
-
-
-
-
-
EXISTING AT&T ANTENNAS
AND ANCILLARY TO REMAIN
CABLE TYPE
TMA / RAYCAP /
DIPLEXER MODEL
 ANTENNA MODEL
RAD CENTER
AZIMUTH
CABLE
LENGTH
JUMPER
LENGTH
RRH / RRU MODEL
POSITION
ACTIVE
TECH.
CABLE TYPE
TMA / RAYCAP /
DIPLEXER MODEL
 ANTENNA MODEL
RAD CENTER
AZIMUTH
CABLE
LENGTH
JUMPER
LENGTH
RRH / RRU MODEL
POSITION
ACTIVE
TECH.
BETA SECTOR
GAMMA SECTOR
-
4
-
-
-
-
-
-
-
1
-
-
2
-
3
-
-
-
-
-
-
4
-
-
-
-
-
1
-
-
2
-
3
-
-
-
-
-
-
4
-
-
-
-
-
-
-
-
EXISTING AT&T ANTENNA
MOUNT
EXISTING 110'-0" SBA MONOPOLE
-
-
-
-
-
80010766K
(REMAIN)
0°
98.00'
80010766K
(REMAIN)
0°
98.00'
80010766K
(REMAIN)
0°
98.00'
180'
-
-
-
-
850 RRH(REMAIN)
FIBER (REMAIN)
(1)
(1)
180'
850 RRH(REMAIN)
FIBER (REMAIN)
(1)
(1)
180'
80010766K
(REMAIN)
120°
98.00'
80010766K
(REMAIN)
98.00'
80010766K
(REMAIN)
98.00'
80010766K
(REMAIN)
98.00'
80010766K
(REMAIN)
240°
98.00'
80010766K
(REMAIN)
98.00'
80010766K
(REMAIN)
98.00'
80010766K
(REMAIN)
98.00'
120°
120°
120°
240°
240°
240°
±Ø1'-10"
±Ø17'-11"

AZ45116
13649 WEST NORTHERN AVE
GLENDALE, AZ 85307
07/27/22
08/02/22
02/21/23
A
0
1
90% CUP REVIEW
100% FINAL CUP
JURISDICTION COMMENTS
NO.
DATE
REVISION
DRAWN
RA
KM
YK
CONSULTANT:
A&E CONSULTANT, SITE ACQUISITION AND PERMITTING:
SHELIA
EXISTING
ELEVATIONS
A-3
EXISTING NORTH ELEVATION
2
22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0"
8'
6'
4'
0"
8'
2'
NOTE:
ALL EXISTING EQUIPMENT SHALL
REMAIN. NO CHANGES ARE
PROPOSED AT THIS TIME.
EXISTING WEST ELEVATION
1
22"x34" SCALE: 1/8" = 1'-0"
11"x17" SCALE: 1/16" = 1'-0"
8'
6'
4'
0"
8'
2'
EXISTING AT&T  ANTENNA CENTERLINE
98.0' AGL
EXISTING GRADE
0.0' AGL
EXISTING TOP OF LIGHTNING ROD
112.6' AGL
EXISTING TOP OF MONOPINE
110.0' AGL
EXISTING AT&T ANTENNAS
AND ANCILLARY EQUIPMENT
EXISTING  ANTENNA CENTERLINE
71.5' AGL
EXISTING 7'-0" CHAINLINK
FENCE
EXISTING 6'-0" HIGH CMU
BLOCK WALL
EXISTING 14'-4" x 23'-6"
AT&T SHELTER
EXISTING ANTENNAS
BY OTHERS
EXISTING 110'-0" SBA MONOPOLE
EXISTING AT&T  ANTENNA CENTERLINE
98.0' AGL
EXISTING GRADE
0.0' AGL
EXISTING TOP OF LIGHTNING ROD
112.6' AGL
EXISTING TOP OF MONOPINE
110.0' AGL
EXISTING AT&T ANTENNAS
AND ANCILLARY EQUIPMENT
EXISTING  ANTENNA CENTERLINE
71.5' AGL
EXISTING 7'-0" CHAINLINK
FENCE
EXISTING 14'-4" x 23'-6"
AT&T SHELTER
EXISTING ANTENNAS
BY OTHERS
NOTE:
ALL EXISTING EQUIPMENT SHALL
REMAIN. NO CHANGES ARE
PROPOSED AT THIS TIME.
EXISTING 110'-0" SBA MONOPOLE
EXISTING 6'-0" HIGH CMU
BLOCK WALL

Planning & Development  
301 W. Jefferson St., Suite 170  
Phoenix, Arizona 85003 
Maricopa.gov 
 
 
 
 
 
ENGINEERING PLAN REVIEW COMMENTS 
 
Revised 2/1/23 
 
Page 1 of 3 
 
Date:    
February 3, 2023 
 
Memo To: Darren Gerard, AICP, Deputy Director, Department of Planning & Development 
 
Attn: 
Paola Jaramillo Quintero, Planner, Planning & Development Services  
 
 
From: 
Jeri Loucks, P.E.C.F.M., Plans Examiner Engineer (Drainage), Planning & Development 
Services  
 
cc: 
Michael Norris, P.E., Drainage Engineering Manager, Planning & Development 
 
Subject:   
MCP2022009 – CUP RENEWAL (SBA 2012 TC Assets) 
 
Job Site Address: 13649 W Northern Ave, Glendale, Az 85307 
 
APN(s): 
501-52-003B 
 
 
Engineering Review has reviewed the first plan and report routed for review on 12/23/2022, for the subject 
application and has no objections. 
   
PND engineering plan review has no objections to the MCP.  
 
Please contact me if you have any questions or require any additional information.

Planning & Development  
301 W. Jefferson St., Suite 170  
Phoenix, Arizona 85003 
Maricopa.gov 
 
 
 
 
 
ENGINEERING PLAN REVIEW COMMENTS 
 
Revised 2/1/23 
 
Page 2 of 3 
 
DRAINAGE PLAN REVIEW REFERENCES:   
 
The Drainage Regulations are listed in Section 1205 of the MCZO: 
https://www.maricopa.gov/documentcenter/view/272  
Maricopa County Drainage Policies and Standards Manual: 
https://www.maricopa.gov/DocumentCenter/Home/View/2369  
For Additional Information See: 
https://www.maricopa.gov/1635/Drainage-Review 
 
FLOOD CONTROL DISTRICT OF MARICOPA COUNTY REFERENCES:   
 
Floodplain Regulations for Maricopa County: 
https://www.maricopa.gov/DocumentCenter/View/630  
For Additional Information See: 
https://www.maricopa.gov/3847/Flood-Control-District  
 
MCDOT REFERENCES: 
 
Residential Driveway Guidelines 
https://www.maricopa.gov/documentcenter/view/362  
Roadway Design Manual 
http://www.mcdot.maricopa.gov/DocumentCenter/View/24883 
Maricopa County Ordinance for Work in R/W 
MCDOT Ordinance P36 
For Additional Information See: 
https://www.maricopa.gov/156/MCDOT  
 
PND STORMWATER REFERENCES: 
 
Stormwater Quality Management and Discharge Control Regulation 
https://www.maricopa.gov/DocumentCenter/View/6577 
Air Pollution Control Regulations Rule 310 
https://www.maricopa.gov/DocumentCenter/View/5354  
For Additional Information See: 
https://www.maricopa.gov/3980/Water-Sewage-Stormwater-Waste

Planning & Development  
301 W. Jefferson St., Suite 170  
Phoenix, Arizona 85003 
Maricopa.gov 
 
 
 
 
 
ENGINEERING PLAN REVIEW COMMENTS 
 
Revised 2/1/23 
 
Page 3 of 3 
 
Abbreviations Key: 
 
Drainage: 
 
DD =   
Department Directive (See: http://www.maricopa.gov/1911/Department-Directives) 
MCZO = 
Maricopa County Zoning Ordinance 
DPSM =  
Maricopa County Drainage Policies and Standards 
SSA =  
State Standard Attachment 
DDMV1=  
Maricopa County Drainage Design Manual – Hydrology 
DDMV2 =  
Maricopa County Drainage Design Manual – Hydraulics 
 
Flood Control: 
 
FRMC = 
Floodplain Regulations for Maricopa County 
 
PND Transportation: 
 
RDM =  
MCDOT Roadway Design Manual 
RDG =  
MCDOT Residential Design Guidelines 
MSRP =  
MCDOT Major Streets and Routes Plan

Page | 1  
 
 
 
 
Maricopa County 
Environmental Services Department 
Water and Waste Management 
 
 
 
 
 
 
 
 
 
 
 
The Maricopa County Environmental Services Department (MCESD) has completed review for the  
Sheila MCP without Plan of Development Wireless Telecommunications Facility planning case(s). 
Please note the following MCESD requirements for site development: 
Additional Notes –  
Environmental Services does not require these items for condition of approval of  MCP2022009 , 
however these items must be addressed with the development of the site. Environmental Services 
does not require additional review of this case. 
 
*It should be noted that this document does not approve the referenced project. Comments are 
provided for the benefit of the applicant for MCESD permit requirements and as an advisory to 
Maricopa County Planning and Development Department. Other Maricopa County agencies may 
have additional requirements. Final review and approval will be made through Planning and 
Development Department procedures. Applicant may need to submit separate applications to the 
Maricopa County Environmental Services Department for approval of proposed facilities regulated 
by the Department. Review of any such application will be based on current regulations at the time 
of application. 
 
 
 
 
Project Name:  Sheila MCP without Plan of 
Development Wireless Telecommunications 
Facility 
Primary Contact Name:  Nicole Comach 
Planning Application Type: Military 
Compatibility Permit 
APN(s):  501-52-003A 
Reviewer: Souren Naradikian, P.E. 
Email: Souren.Naradikian@maricopa.gov 
Phone: 602-372-2907 
Planner Name:  Paola Jaramillo 
Planning Case #:  MCP2022009  
Date: January 24, 2023 
 
Subdivision Infrastructure  
& Planning Program 
301 W. Jefferson St. 
Phoenix, AZ 85003 
 
Subdivision@maricopa.gov 