Good afternoon Evan,
Through Councilmember Goforth, I have received and reviewed the updated site plan and
architectural plan set (ZON26-00419) for the proposed Longbow Hotel project.
While the Red Mountain Ranch stakeholder community appreciates the ground-level
landscaping, pedestrian sidewalks, and the drive-thru restrictions you secured, we have
completed a thorough audit of the building elevations and materials. Since the developer has
chosen to advance a 3-story "by-right" model and bypass the higher-tier brand incentive
package, the architecture has unfortunately been stripped down to a baseline, budget-tier
product.
As currently drawn, the building envelope fails to meet the character, material quality, and
acoustic mandates set forth in the Mesa 2050 General Plan (Chapter 4) and the Falcon Field
Airport Overlay Zone.
We request that the Planning Department and the Design Review Board address the following
critical non-compliance items before this project moves forward:
1. Mechanical Deficiencies (Packaged Terminal Air Conditioner Wall Vents): Plan
sheets 4 and 6 explicitly call out individual Packaged Terminal Air Conditioner (PTAC)
wall-vent grilles punctured through the exterior facade beneath every guest window.
This mechanical configuration is characteristic of budget roadside motels, not a premier
employment core. It directly conflicts with the "Aviation-Contemporary" design
mandate. We require a clean, modern facade utilizing centralized rooftop Heating,
Ventilation, and Air Conditioning (HVAC) units with zero exterior wall penetrations.
2. Material Deficiencies (Substandard Legend): The material matrix on Page 4 relies on
a combined 69% smooth stucco and fiber-cement board composition. This material
legend mimics standard residential apartment design and lacks the high-quality,
durable, and sophisticated aesthetic required by Chapter 4 of the Master Plan for the
Falcon District. The cement board siding should be replaced with high-end architectural
metal panels or composite rain-screens to give the building true character.

3. Acoustic Non-Compliance (Flight Path Under-Protection): General Note #1 on Page
4 establishes a minimum window rating of Sound Transmission Class 30 (STC-30). An
STC-30 rating is standard residential grade and is wholly inadequate for a commercial
lodging asset sitting directly underneath active Falcon Field flight paths. To safeguard
the guest experience and protect the long-term operational integrity of the airport, the
building envelope must be held to a premium acoustic standard of minimum Sound
Transmission Class 50 (STC-50).
The citizens of Northeast Mesa have worked for over two decades to cultivate an upscale,
high-tech image for this corridor. We cannot support a design that settles for a budget
aesthetic.
Given the structural nature of these architectural and acoustic concerns, I request a meeting
with you, your project review team, and Councilmember Goforth's office to discuss how the
applicant intends to rectify these deficiencies before a formal Design Review Board hearing is
scheduled. We look forward to seeing these building items corrected to align with Mesa's
2050 vision.