Extracted text (via pymupdf)
5877 characters
PROJECT LOCATION LAGOON Scale Date Drawn By Checked By Project Number 15035 N. 73RD STREET, BUILDING D, SCOTTSDALE, AZ 85260 480.389.2939 : info@mandmds.com : mandmds.com Project NOT FOR CONSTRUCTION 1" = 80'-0" SD0.01 REFERENCE SITE PLAN Cannon Beach Hotel BDM RS 1/15/2026 2023_01 4503 S Power Rd Gilbert, AZ 85296 1" = 80'-0" 1 REFERENCE SITE PLAN No. Description Date VICINITY MAP PROJECT LOCATION CITY OF MESA GENERAL NOTES: COMPLY WITH ALL PROVISIONS AND REQUIREMENTS OF MESA BUILDING CODE (MBC) CHAPTER 33 - SAFEGUARDS DURING CONSTRUCTION, MESA FIRE CODE (MFC) CHAPTER 33 - FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION, AND NFPA 241 FOR ITEMS NOT SPECIFICALLY ADDRESSED BY MFC CHAPTER 33.” “FIRE APPARATUS ACCESS ROADS ARE ESSENTIAL DURING CONSTRUCTION TO ALLOW EMERGENCY RESPONSE TO THE SITE FOR BOTH FIRE AND MEDICAL EMERGENCIES. ACCESS ROADS SHALL BE IN PLACE PRIOR TO THE START OF VERTICAL CONSTRUCTION. IT IS IMPORTANT TO DEVELOP ACCESS ROADS AT AN EARLY STAGE OF CONSTRUCTION TO ALLOW FOR FIRE DEPARTMENT ACCESS TO THE SITE IN THE CASE OF FIRE OR INJURY.” B. REQUIRED FIRE APPARATUS ACCESS ROAD SHALL COMPLY WITH MESA FIRE AND MEDICAL DEPARTMENT STANDARD DETAIL FPD 3310.1. THE ACCESS ROAD SHALL BE A MINIMUM OF 20 FEET WIDE OF ALL-WEATHER DRIVING SURFACE, GRADED TO DRAIN STANDING WATER AND ENGINEERED TO BEAR THE IMPOSED LOADS OF FIRE APPARATUS (78,000 LBS. / 24,000 LBS. FRONT AXLE, 54,000 LBS. REAR AXLE) WHEN ROADS ARE WET. AND/OR ANY LOCATION ON THE JOBSITE WHERE ANY PERSON(S) SHALL BE WORKING FOR A MINIMUM OF FOUR (4) CONTINUOUS HOURS IN ANY DAY. A CLEARLY VISIBLE SIGN MARKED “FIRE DEPARTMENT ACCESS”, IN RED LETTERS, SHALL BE PROVIDED AT THE ENTRY TO THE ACCESS ROAD. ALL OPEN TRENCHES SHALL HAVE STEEL PLATES CAPABLE OF MAINTAINING THE INTEGRITY OF THE ACCESS ROAD DESIGN WHEN THESE TRENCHES CROSS AN ACCESS ROAD. THESE ACCESS ROADS MAY BE TEMPORARY OR PERMANENT. THIS POLICY APPLIES ONLY DURING CONSTRUCTION AND/OR DEMOLITION. PERMANENT ACCESS PER THE MFC SHALL BE IN PLACE PRIOR TO ANY FINAL INSPECTION OR CERTIFICATE OF OCCUPANCY.” C. “WATER SUPPLY FOR FIRE PROTECTION. AN APPROVED WATER SUPPLY FOR CONSTRUCTION SITE SHALL MEET THE REQUIREMENTS OF MFC APPENDIX CHAPTERS B AND C. THE MINIMUM FIRE FLOW REQUIREMENT WHEN CONTRACTOR OR DEVELOPER BRINGS COMBUSTIBLE MATERIALS ON SITE IS 1,500 GPM AT 20 PSI. AT LEAST ONE FIRE HYDRANT SHALL BE WITHIN 500 FEET OF ANY COMBUSTIBLE MATERIAL AND CAPABLE OF DELIVERING THE MINIMUM FIRE FLOW REQUIREMENT. THIS HYDRANT OR HYDRANTS MAY BE EITHER TEMPORARY OR PERMANENT AS THE PROJECT SCHEDULE PERMITS. IN ADDITION, THERE ARE TIMES WHEN HYDRANTS AND VALVES MUST BE CLOSED TEMPORARILY FOR REPAIR WORK OR CONSTRUCTION OF THE WATER SYSTEM. THE DEVELOPER/CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT THE WATER SUPPLY IS ALWAYS AVAILABLE. WHEN THE WORK IS COMPLETE, DEVELOPER/CONTRACTOR SHALL MAKE SURE THAT THE FIRE HYDRANTS ARE ACTIVE, AND THE VALVES ARE OPEN. 3/13/2026 1 1 1 1 2 3 4 5 6 8 7 9 9 10 11 12 13 14 15 17 17 18 18 1 12 16 16 1 DRIVE AISLE 16' - 0" DRIVE 15' - 0" DRIVE 15' - 0" PUE: 1719-35 PUE: 1719-35 PUE: 1719-35 PUE: 1667-18 PUE: 1667-18 PUE: 1622-20 1 17' - 1" 14' - 11 1/2" 27' - 7" 41' - 9" 5' - 7" 5' - 0" 5' - 0" ONE-WAY 20 20 29' - 3" 1,220 SF ENTRY PLAZA WALK CONTINUES SOUTH, TRANSITIONS TO ENTRY PLAZA MATERIAL WALK CONTINUES NORTH, TRANSITIONS TO ENTRY PLAZA MATERIAL KEYED NOTES 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. LANDSCAPE AREA DRIVE AISLE PORTE-COCHERE RESTAURANT ENTRY EVENT LAWN SES ELECTRICAL LOCATION FOR PAD-MOUNTED TRANSFORMER FIRE RISER BIKE RACK POOL + HOT TUB MAIN HOTEL ENTRY SURFBOARD LOCKERS LOADING DOCK COMPACTOR COVERED DINING PATIO ENTRY TO PRE-FUNCTION ENTRY POINT TO HOTEL MAIN BOARDWALK WATER FEATURE FENCE WITH ROLLING GATE Scale Date Drawn By Checked By Project Number 15035 N. 73RD STREET, BUILDING D, SCOTTSDALE, AZ 85260 480.389.2939 : info@mandmds.com : mandmds.com Project NOT FOR CONSTRUCTION As indicated SD0.02 ARCHITECTURAL SITE PLAN Cannon Beach Hotel BDM RS 3/13/2026 2023_01 4503 S Power Rd Gilbert, AZ 85296 1/16" = 1'-0" 1 ARCHITECTURAL SITE PLAN No. Description Date PROJECT LOCATION VICINITY MAP ACCOMMODATION DATA: GROUND FLOOR PORTE-COCHERE: RECEPTION: LOBBY LOUNGE: LOBBY BAR & CAFE: FITNESS ROOM: RESTAURANT: PRE-FUNCTION AREA: 5,000 SF BALLROOM: EVENT LAWN: POOL: BOH OFFICES: EMPLOYEE AREA: LOADING DOCK: TWO LINE KITCHEN: SURFBOARD STORAGE ROOM: 2ND FLOOR 2 X KING FAMILY SUITES + SLEEPER SOFA: 1 X KING SUITE: 19 X DOUBLE ROOMS: 15 X KING ROOMS: HOUSEKEEPING: ICE & VENDING: 3RD FLOOR 2 X KING FAMILY SUITES + SLEEPER SOFA: 1 X KING SUITE: 19 X DOUBLE ROOMS: 15 X KING ROOMS: HOUSEKEEPING: ICE & VENDING: 4TH FLOOR 1 X KING FAMILY SUITE + SLEEPER SOFA: 1 X OWNERS SUITE + SLEEPER SOFA: 1 X KING SUITE: 19 X DOUBLE ROOMS: 15 X KING ROOMS: HOUSEKEEPING: ICE & VENDING: 5TH FLOOR 1 X KING FAMILY SUITE + SLEEPER SOFA: 17 X DOUBLE ROOMS: 14 X KING ROOMS: HOUSEKEEPING: ICE & VENDING: EVENT DECK: HOT TUB EVENTBAR: PREP & STORAGE: GUEST ROOMS: 6 X KING FAMILY SUITES: 3 X KING SUITES: 1 X KING OWNERS SUITE: 59 X KING ROOMS: 74 X DOUBLE ROOMS: TOTAL GUEST ROOMS: 143 ROOMS BUILDING AREA 1ST FLOOR PLATE: 25,502 SF 2ND FLOOR PLATE: 21,138 SF 3RD FLOOR PLATE: 21,138 SF 4TH FLOOR PLATE: 21,138 SF 5TH FLOOR PLATE: 21,082 SF 5-STORIES: +/- 109,998 SF BUILDING HEIGHT ROOF: 61' - 0" T.O. MECHANICAL PENTHOUSE: 71' - 0" (65' MAX ALLOWED - SPECIAL USE PERMIT REQUEST FOR UP TO 75' MAX FOR PENTHOUSE ONLY, ROOF OF BUILDING TO COMPLY WITH 65'-0" MAX HEIGHT) SITE DATA APN: 304-30-956 LOT AREA: 57,648 SF (+/- 1.32 ACRE) BUILDING AREA: +/-25,502 SF PORTE COCHERE (COVERED ROOF AREA): 1,300 SF HARDSCAPE: +/- 9,467 SF TOTAL COVERAGE = 36,269 SF / 57,648 SF (63%) ZONE: GC AF-PAD-CUP 4/27/2026