Floor Plan

City of Mesa — Design Review Board (2026-04-14)

View PDF Meeting page

Extracted text (via pymupdf) 4359 characters
49' - 6 5/8"
FELLOWSHIP
HALL
KITCHEN
EQ STORAGE
A400
2
72' - 0"
A400
3
A400
4
A400
1
HALLWAY
WOMEN'S
MEN'S
ENTRY
PANTRY
STORAGE
20' - 0"
69' - 11 1/2"
72' - 2"
90' - 2"
8' - 1"
9' - 0"
16' - 0"
5' - 0"
22' - 8 7/8"
7' - 7 1/8"
12' - 4 7/8"
4' - 9 3/8"
1' - 0"
3603 SF
231 OCCUPANT
2 EXITS
438 SF
5 OCCUPANTS
1 EXIT
REF.
OVEN
OVEN
SINK
REF.
BASE CABINETS
W/ COUNTERTOP
WALL CABINETS
EQ
EQ
ELEC.
FIRE RISER
NOTE: ALL DOORS FOR ACCESSIBLE PASSAGE SHALL COMPLY WITH THE 
FOLLOWING EXCEPT FOR REACH-IN CLOSETS:
1. 
MINIMUM CLEAR OPENING WIDTH, 32" WITH DOOR OPEN AT 90 DEGREES.
2. 
MANEUVERING CLEARANCE PER DETAIL ON SHEET A500.
3. 
MAXIMUM 1/2" THRESHOLD HEIGHT - BEVEL THRESHOLD.
4. 
ALL DOOR HARDWARE SHALL BE LEVER OPERATED - SCHLAGE S-SERIES -
SATURN LEVER HANDLE OR EQUIVALENT.
5. 
DOOR HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERATION DEVICES 
ON DOORS REQUIRED TO BE ACCESSIBLE BY ADA SHALL NOT REQUIRE TIGHT 
GRASPING, TIGHT PINCHING, OR TWISTING OF THE WRIST TO OPERATE
6. 
HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON 
DOORS AND GATES SHALL BE 34" MINIMUM AND 48" MAXIMUM ABOVE FINISH 
FLOOR.
7. 
WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING 
HARDWARE SHALL BE EXPOSED AND USABALE FROM BOTH SIDES.
8. 
DOOR OPENING FORCE SHALL NOT EXCEED 5 lbf FOR INTERIOR DOORS.
9. 
REFER TO ADA DETAILS ON SHEET A500 FOR RESTROOM CLEARANCES.
10. REFER TO ADA DETAILS ON SHEET A500 FOR DOOR CLEARANCES.
11. THE DESIGN AND CONSTRUCTION OF THIS SPACE SHALL MEET CURRENT ADA 
REQUIREMENTS.
12. SHELL BUILDING COMPLIES WITH SECTIONS 1104 (ACCESSIBLE ROUTE), 1105 
(ACCESSIBLE ENTRANCES) OF IBC AND APPENDIX B (SUPPLEMENTARY 
ACCESIBILITY REQUIREMENTS FOR EXISTING BUILDINGS AND FACILITIES) OF 
THE IEBC.
13. ACCESSIBLE LOCATIONS FOR WHEELCHAIRS ARE LOCATED IN ALL AREAS 
WITH FIXED SEATING.
1. 
CONTRACTOR SHALL PROVIDE WOOD OR STEEL BLOCKING AT WALL 
MOUNTED EQUIPMENT AND MILLWORK
2. 
CONTRACTOR SHALL COORDINATE ALL COMPUTER AND NETWORK 
REQUIREMENTS WITH TENANT AND TENANT'S EQUIPMENT SUPPLIER PRIOR 
TO CONSTRUCTION
3. 
PROVIDE ONE FIRE EXTINGUISHER (2A:10BC) PER 3,000 SF
4. 
CONTRACTOR TO COORDINATE WITH BUILDING INSPECTOR FOR LOCATION 
OF FIRE EXTINGUISHER CABINETS - PROVIDE SEMI-RECESSED CABINETS
5. 
ALL WALLS WITH PLUMBING FIXTURES AND WALLS ADJACENT TO PLUMBING 
FIXTURES TO BE WATER RESISTANT G.W.B.
6. 
PROVIDE ADDRESS/SUITE NUMBERS AT ALL EXTERIOR SUITE DOORS, MIN 3" 
HIGH WITH 1/2" STROKE WIDTH AND IN CONTRASTING COLORS; MUST BE 
VISIBLE FROM THE STREET OR DRIVE
A. 
DO NOT SCALE THE DRAWINGS - CONTACT ARCHITECT FOR ANY 
MISSING DIMENSIONS.
B. 
VERIFY ALL DIMENSION IN FIELD WITH OWNER.
C. 
UNO, DIMENSIONS ARE TO THE FINISHED FACE OF WALLS.
D. 
UNO IN PLAN OR ELEVATIONS, MILLWORK BASE CABINETS ARE 24" DEEP 
AND MILLWORK WALL CABINETS ARE 14" DEEP.
E. 
VERIFY ALL OWNER SUPPLIED EQUIPMENT LOCATION AND DIMENSIONS. 
THE OWNER SHALL VERIFY CRITICAL DIMENSIONS PRIOR TO 
CONSTRUCTION OF PARTITIONS.
F. 
CONTRACTIOR SHALL VERIFY ALL EXISTING DIMENSIONS AND CONTACT 
THE ARCHITECT WITH ANY DISCREPANCIES.
G. REFER TO ELEVATIONS FOR ADDITIONAL DIMENSIONS.
H. 
ALL NEW WALLS ARE 3-5/8" STUD WALLS UNO.
DRAWING NUMBER
PROJECT NUMBER
DRAWING TITLE
Plot Date:
SEALS AND SIGNATURES
ISSUED FOR
REV
DATE
DATE
© COPYRIGHT 2024 VALLEY ARCHITECTURE, INC. 
IN ORDER TO USE THESE DRAWINGS, GENERAL CONTRACTOR MUST 
VERIFY ALL EXISTING SITE AND ANY EXISTING BUILDING CONDITIONS, 
INCLUDING EXISTING GRADES, AND EXISITNG UTILITIES PRIOR TO 
BEGINNING CONSTRUCTION. GENERAL CONTRACTOR ALSO MUST VERIFY 
ALL DIMENSIONS BEFORE BEGINNING CONSTRUCTION. ANY DISCREPANCY 
MUST BE REPORTED BY GENERAL CONTRACTOR TO VALLEY 
ARCHITECTURE, INC. WITH A WRITTEN RFI FOR RESOLUTION PRIOR TO 
INITIATING THE WORK. 
VALLEY ARCHITECTURE, INC.
1248 N. HILLCREST
MESA, AZ 85201
602.334.9766
RON@VALLEYARCH.COM
12/15/2025 3:47:54 PM
F:\Dropbox\^Projects\2024\VAI2421 New Life Bldg\01 PLANS\RVT\2421 NEW LIFE 12-15-25.rvt
FLOOR PLAN
A200
VAI2421
DRB
NEW BUILDING FOR:
NEW LIFE - FELLOWSHIP BUILDING
1718 W. BROADWAY RD.
MESA, AZ 85202
12.02.25
0
4'
8'
16'
3/16" = 1'-0"
11 FLOOR PLAN
Accessibility Notes
General Notes
Dimension Notes
COVERED ENTRY PATIO
47331
RONALD
HECHT, JR
R
E
G
I
S
T
E
R
E
D
A
R
C
H
I
T
E
C
T
C
E
R
T
I
F
I
C
A
T
E
N
O
.
.
.
.
.
.
d
e
n
g
i
S
e
t
a
D
.
A
.
S
.
U
,
A
N
O
Z
I
R
A
.
.
.
.
.
EXPIRES 3.31.29
03.24.26
FINAL APPROVAL SET