WITH FENCED COMPRESSOR SHED GENERAL DRAWING NOTES A. REFER TO THE A0.X SERIES DRAWINGS FOR ARCHITECTURAL ANOTES, DRAWING, REFERENCE AND MATERIAL SYMBOLS AS WELL AS ABBREVIATIONS USED ON THIS DRAWING. B. FOR BASIC LIFE SAFETY AND CODE INFORMATION APPLYING TO THIS PROJECT, REFER TO G.X SERIES LOCATED PER THE PROJECT SHEET INDEX. C. REFER TO A2.X.X SERIES FOR ARCHITECTURAL FLOOR PLANS, ROOF PLANS, & TILT WALL COORDINATION INFORMATION. D. REFER TO AND COORDINATE WITH CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL SITE INFORMATION NOT SHOWN ON THIS DRAWING. E. SITE SCREEN WALLS A MAXIMUM 8'-0" ABOVE THE HIGHEST FINISHED GRADE OF THE PARKING AREA OR STREET CURB. WHICHEVER IS HIGHER. F. REFER TO AND COORDINATE WITH CIVIL DRAWINGS FOR ALL FINISH GRADES. G. REFER TO A4.X.X SERIES DRAWINGS FOR ENLARGED EXTERIOR ELEVATIONS, BUILDING SECTIONS, TILT WALL ELEVATIONS, & WALL SECTIONS. PROJECT LOCATION E PECOS ROAD S ELLSWORTH ROAD E GERMANN ROAD S 89TH PLACE S ATWOOD S 88TH STREET VICINITY MAP PROJECT DATA PROJECT NAME: PROJECT ADDRESS: CLIENT: APPLICANT: PROJECT SCOPE: ASSESSOR PARCEL NO,: CURRENT ZONING: NET SITE AREA: GROSS SITE AREA: LANDSCAPE AREA: LOT COVERAGE: STORIES: BUILDING AREA (GROSS): OCCUPANCY: CONSTRUCTION TYPE: SPRINKLERS: BUILDING HEIGHT: KALTECH EXPANSION 7307 S 89TH PLACE MESA, AZ 85212 KINGDON GATEWAY, LLC AN ARIZONA LIMITED LIABILITY COMPANY 273 W BERGER LANE MURRAY, UT 84107 PHONE: 480-539-0684 E-MAIL: sdavidsen@kaltechglobal.net LGE DESIGN GROUP CONTACT: BILL JEORLING 1200 NORTH 52ND STREET PHOENIX, AZ 85008 PHONE: 480-966-4001 E-MAIL: bjeorling@lgedesignbuild.com OFFICE/WAREHOUSE ADDITION 304-62-153, 304-62-154 LI PAD (ZONING TO REMAIN) +/- 69,838 S.F. (1.60 ACRES) +/- 80,908 S.F. (1.86 ACRES) X 24% ONE STORY WITH MEZZANINE 16,730 S.F. TOTAL 11,810 S.F. EXISTING 4,920 S.F. ADDITION B, S V-B W/ A.F.E.S. YES/FULLY SPRINKLED +/- 26'-8" VEHICULAR PARKING CALCS: PARKING REQUIRED (EXISTING BUILDING): USE SQ. FT. FACTOR TOTAL OFFICE 3,623 S.F. 1/300 S.F. 13 SPACES WAREHOUSE 11,810 S.F. 1/500 S.F. 17 SPACES PARKING REQUIRED: 30 SPACES PARKING REQUIRED (EXPANSION): USE SQ. FT. FACTOR TOTAL OFFICE 3,120 S.F. 1/375 S.F. 9 SPACES WAREHOUSE 1,800 S.F. 1/500 S.F. 4 SPACES PARKING REQUIRED: 13 SPACES TOTAL PARKING REQUIRED: 43 SPACES PARKING PROVIDED TOTAL SPACES ON SITE 53 SPACES (123.2% OF REQ'D) PARKING/BUILDING RATIO: 3.11 CARS PER 1,000 S.F. ACCESSIBLE PARKING CALCS: TOTAL PARKING OF 51 TO 75 SPACES REQUIRES 3 ACCESSIBLE SPACES REQUIRED: 3 SPACES PROVIDED: 4 SPACES THIS PROJECT IS A NEW 4,920 SQUARE FOOT OFFICE / WAREHOUSE ADDITION WITH SITE IMPROVEMENTS ON A 1.60 ACRE SITE. PROJECT DESCRIPTION 03/23/2026 JH BJ GENERAL DRAWING NOTES A. REFER TO THE A0.X SERIES DRAWINGS FOR ARCHITECTURAL ANOTES, DRAWING, REFERENCE AND MATERIAL SYMBOLS AS WELL AS ABBREVIATIONS USED ON THIS DRAWING. B. FOR BASIC LIFE SAFETY AND CODE INFORMATION APPLYING TO THIS PROJECT, REFER TO G.X SERIES LOCATED PER THE PROJECT SHEET INDEX. C. REFER TO A2.X.X SERIES FOR ARCHITECTURAL FLOOR PLANS, ROOF PLANS, & TILT WALL COORDINATION INFORMATION. D. REFER TO AND COORDINATE WITH CIVIL, LANDSCAPE, STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL SITE INFORMATION NOT SHOWN ON THIS DRAWING. E. SITE SCREEN WALLS A MAXIMUM 8'-0" ABOVE THE HIGHEST FINISHED GRADE OF THE PARKING AREA OR STREET CURB. WHICHEVER IS HIGHER. F. REFER TO AND COORDINATE WITH CIVIL DRAWINGS FOR ALL FINISH GRADES. G. REFER TO A4.X.X SERIES DRAWINGS FOR ENLARGED EXTERIOR ELEVATIONS, BUILDING SECTIONS, TILT WALL ELEVATIONS, & WALL SECTIONS. PROJECT LOCATION E PECOS ROAD S ELLSWORTH ROAD E GERMANN ROAD S 89TH PLACE S ATWOOD S 88TH STREET VICINITY MAP PROJECT DATA PROJECT NAME: PROJECT ADDRESS: CLIENT: APPLICANT: PROJECT SCOPE: ASSESSOR PARCEL NO,: CURRENT ZONING: NET SITE AREA: GROSS SITE AREA: LANDSCAPE AREA: LOT COVERAGE: STORIES: BUILDING AREA (GROSS): OCCUPANCY: CONSTRUCTION TYPE: SPRINKLERS: BUILDING HEIGHT: OH DOOR COUNT: KALTECH EXPANSION 7307 S 89TH PLACE MESA, AZ 85212 KINGDON GATEWAY, LLC AN ARIZONA LIMITED LIABILITY COMPANY 273 W BERGER LANE MURRAY, UT 84107 PHONE: 480-539-0684 E-MAIL: sdavidsen@kaltechglobal.net LGE DESIGN GROUP CONTACT: BILL JEORLING 1200 NORTH 52ND STREET PHOENIX, AZ 85008 PHONE: 480-966-4001 E-MAIL: bjeorling@lgedesignbuild.com OFFICE/WAREHOUSE ADDITION 304-62-153, 304-62-154 LI PAD (ZONING TO REMAIN) +/- 69,838 S.F. (1.60 ACRES) +/- 80,908 S.F. (1.86 ACRES) 16,326 S.F. 23.4% ONE STORY WITH MEZZANINE 16,700 S.F. TOTAL 11,810 S.F. EXISTING 4,890 S.F. ADDITION B, S V-B W/ A.F.E.S. YES/FULLY SPRINKLED +/- 30'-0" 4 VEHICULAR PARKING CALCS: PARKING REQUIRED (EXISTING BUILDING): USE SQ. FT. FACTOR TOTAL OFFICE 3,623 S.F. 1/300 S.F. 13 SPACES WAREHOUSE 11,810 S.F. 1/500 S.F. 17 SPACES PARKING REQUIRED: 30 SPACES PARKING REQUIRED (EXPANSION): USE SQ. FT. FACTOR TOTAL OFFICE 3,098 S.F. 1/375 S.F. 9 SPACES WAREHOUSE 1,792 S.F. 1/500 S.F. 4 SPACES PARKING REQUIRED: 13 SPACES TOTAL PARKING REQUIRED: 43 SPACES PARKING PROVIDED TOTAL SPACES ON SITE 53 SPACES (123.2% OF REQ'D) PARKING/BUILDING RATIO: 3.11 CARS PER 1,000 S.F. ACCESSIBLE PARKING CALCS: TOTAL PARKING OF 51 TO 75 SPACES REQUIRES 3 ACCESSIBLE SPACES REQUIRED: 3 SPACES PROVIDED: 4 SPACES THIS PROJECT IS A NEW 4,890 SQUARE FOOT OFFICE / WAREHOUSE ADDITION WITH SITE IMPROVEMENTS ON A 1.60 ACRE SITE. PROJECT DESCRIPTION EXISTING BUILDING 11,810 S.F. EXPANSION 4,920 S.F. WAREHOUSE 1,800 S.F. 2 STORY OFFICE 3,120 S.F. 4' - 0" 5' - 6" 32 EXISTING PARKING SPACES 28 NEW PARKING SPACES TYP. 9' - 0" 8' - 0" 18' - 0" SETBACK 20' - 0" SETBACK 7' - 6" SETBACK 7' - 6" R 35' - 0" R 35' - 0" 24'-0" WIDE FIRE LANE REORIENT REFUSE ENCLOSURES EXISTING 6' CMU WALL REMOVE EXISTING GATE & WALL CONCRETE APRON WITH FENCED COMPRESSOR SHED FIRE TRUCK TURN-AROUND 50' BACK-UP CLEARANCE FOR REFUSE TRUCK (7) 14'X30' COMPANY VAN PARKING LANDSCAPING NOT REQUIRED WITHIN SCREENER STORAGE AREAS (11-30-7. C.2.) NEW 8' PERIMETER CMU WALL EXISTING ELECTRIC SRP EASEMENT EXISTING EQUIPMENT 8' CMU SCREEN WALL ARTICULATION 8' P.U.F.E. 8' P.U.F.E. NEW DRIVE AND ENTRY GATE WITH "EMPLOYEE ONLY" SIGN EXISTING ACCESS EASEMENT (TO BE ABANDONED) NEW SIDEWALK CONNECTION AND CONTINUE EXISTING SIDEWALK AS REQUIRED NEW CARD READER FOR GATE EXISTING (5) BIKE RACK EXISTING 3' PARKING SCREEN WALL EXISTING DRIVE- ENTRY EXISTING 3' PARKING SCREEN WALL EXISTING 8' ELECTRICAL EASEMENT EXISTING LANDSCAPING TO BE REPLACED BUILDING SETBACK PER PLAT EXISTING CONCRETE APRON 2 EXISTING ADA SPACES EXISTING 6' CMU SCREEN WALL