Project Narrative

City of Mesa — Board of Adjustment Public Hearing (2026-04-01)

View PDF Meeting page

Extracted text (via pymupdf) 13847 characters
DLR Group Inc.
an Arizona corporation 
6225 North 24th Street, Suite 250 
Phoenix, AZ  85016 
 
 
 
Project Narrative 
 
AC Hotel 
112 Main Street, Mesa, AZ  85201 
 
The site is within the FBC area mapped with a Transect Zone of T5 Main Street (T5MS).  The Owner would like to 
request to opt-in to the Form Based Code administrative process. 
 
The new AC Hotel is envisioned as a refined, contemporary destination that embodies the brand’s European-
inspired ethos of timeless simplicity and social connection. Encompassing 88,887 GSF, the hotel program 
balances efficient guestrooms with vibrant public spaces that engage both travelers and the surrounding 
community. The property includes approximately 164 guestrooms in a mix of AC’s signature Metro King, Double 
Queen, and Corner layouts, designed to maximize comfort, efficiency, and a sense of calm retreat. 
 
At the ground floor, the lobby provides a sleek, understated arrival experience that transitions seamlessly into the 
lobby bar and lounge—the social heart of the hotel where guests gather for morning rituals and evening tapas-
style service. To support business and community engagement, the hotel offers flexible meeting space with pre-
function areas, complemented by an outdoor patio for breakout sessions and social events. Parking is 
accommodated in an adjacent structured garage, ensuring ease of access while preserving the site for active, 
guest-focused uses.  There is no occupied open space planned for the rooftop. 
 
The five-story façade is finished in a range of earth-tone EIFS, selected to complement the surrounding 
buildings. Guestroom levels feature large aluminum storefront windows, with individual mechanical grilles 
integrated into the window framing for a cohesive appearance. At the ground floor, expansive storefront glazing 
maximizes daylight and creates a welcoming transparency that draws the community into the bar and lounge. 
 
Landscaping in the ROW will be maintained by the Developer per the Development Agreement.   
 
A limited Dooryard is provided along Main Street.  The majority of the building or 24" stucco planter wall is 
within 4" of the Build-to Line.  A Shopfront is provided on Centennial Way and is the main entry to the hotel.  The 
full width of the shopfront is glazed full height.  the permanent entry canopy extends 5'-0" beyond the property 
line with a clear height of 12'-6".  The outside edge of the canopy is set back 20'-1-1/2" from back of curb line. 
 
Per Table 11-58-3 A of the FBC/MZO, the hotel use is permitted per note 4) The design of the project 
encourages transition of the ground floorspace to active commercial uses in the future by complying with FBC 
building form and private frontage standards for commercial uses.  The ground floor is constructed with 
concrete columns and concrete deck above with a 17’-0” floor to floor height to allow for maximum future 
flexibility for future commercial uses should the hotel use change in the future.  The program for the hotel is 
unique and the brand, Marriott, require a certain amount of back-of house space adjacent to the public uses on

Page 2 
 
 
 
the ground floor to meet guest service expectation.  The proposed limited-service hotel plan was developed with 
a clear focus on functional clarity, guest experience, and operational efficiency, informed by close collaboration 
with Marriott and established hotel best practices. The building massing and program distribution intentionally 
activate two primary elevations with guest-facing uses, including the lobby, registration and arrival sequence, 
dining areas, and associated office and administrative space that works directly in support of the front desk. 
This approach creates an engaging and transparent public realm while reinforcing intuitive wayfinding and a 
welcoming arrival experience. 
Back-of-house and support functions are strategically consolidated and directly connected to service elevators 
to ensure efficient vertical circulation and minimize operational conflicts with guest areas. Laundry, storage, 
and service support spaces are grouped to improve workflow and reduce travel distances for staff. Kitchen 
facilities are centrally positioned to effectively serve both meeting rooms and dining venues, balancing front-of-
house activation with discreet service access. 
Mechanical, electrical, and plumbing spaces are similarly consolidated to optimize building efficiency, simplify 
maintenance, and streamline deliveries and service access. This organizational strategy reflects Marriott’s 
operational guidelines and proven hospitality planning principles, ensuring the hotel functions efficiently while 
maintaining a high-quality guest experience. Overall, the layout represents a thoughtful integration of brand 
standards, operational best practices, and urban design considerations appropriate for the site and its civic 
context. 
 
Board of Adjustment – Variance Requests 
 
Variance 1a – T5MS Building Form: Ground Floor Ceiling Height (MZO §11-58-10(D)) 
Required: 14 feet minimum clear. Proposed: Approximately 13 feet clear in select areas. Floor-to-floor height is 
17’-0”. 
 
A. Special Circumstances Applicable to the Property. The ground floor is designed to be as open and 
inviting as possible, consistent with the Form-Based Code and the City of Mesa General Plan vision for 
an active, pedestrian-oriented downtown. To achieve wider structural spans and reduce interior 
columns and bearing walls, a more substantial reinforced concrete slab is required at Level 2. In 
addition, transitions of vertical plumbing, HVAC risers, fire protection, and life-safety systems serving 
the guestrooms above must occur within the ground-floor ceiling zone. These combined requirements 
necessitate additional interstitial space above the ceiling plane, resulting in localized reductions in 
clear ceiling height. 
 
B. Pre-Existing Nature of the Special Circumstances. These conditions arise from the downtown infill 
context, applicable building and fire code requirements, and the quality and performance expectations 
of a major branded hotel property. 
 
C. Deprivation of Privileges Enjoyed by Other Properties. Strict application of the 14-foot minimum clear 
ceiling height would require increasing overall floor-to-floor heights and total building height, resulting 
in a taller and bulkier building that conflicts with Form-Based Code objectives for scale and massing. 
Without the variance, the project would be deprived of the ability to deliver a commercially viable, high-
quality hotel ground floor comparable to other permitted downtown developments. 
 
D. No Grant of Special Privilege. The Owner has established a 17-foot floor-to-floor height and will make 
best efforts to achieve the maximum feasible clear ceiling height. Approval supports design quality, 
code compliance, and pedestrian activation without granting a special privilege inconsistent with 
surrounding development.

Page 3 
 
 
 
Variance 1b – T5MS Building Form: Upper Floor Ceiling Heights (MZO §11-58-10(D)) 
Required: 9 feet minimum clear. Proposed: Guestroom sleeping areas will achieve 9’-0” clear; guest corridors 
and guest bathrooms will achieve approximately 8’-4” clear. 
 
A. Special Circumstances Applicable to the Property. Guest corridor and bathroom ceiling zones must 
accommodate horizontal plumbing for fixture traps returning to main stacks, code-required outside air 
delivered to guestrooms via horizontal ductwork, and fire sprinkler piping crossing other utilities. These 
systems directly affect ceiling heights in non-sleeping areas. 
 
B. Pre-Existing Nature of the Special Circumstances. These requirements are dictated by life-safety codes, 
mechanical standards, and hospitality industry norms applicable to mid-rise hotel construction. 
 
C. Deprivation of Privileges Enjoyed by Other Properties. Requiring uniform 9-foot ceilings throughout all 
interior spaces would necessitate increased floor-to-floor heights and overall building mass, impairing 
the project’s feasibility as a mid-rise hotel within the T5MS district. 
 
D. No Grant of Special Privilege. All guestroom sleeping areas comply with the minimum ceiling height 
standard, preserving guest comfort and quality. Reduced heights are limited to transient-use spaces 
and enable necessary system coordination without conferring a special privilege. 
 
 
Variance 2 – Mid-Rise Building Type: Building Depth and Footprint (MZO §11-59-13(E)) 
Required: Maximum depth of 150 feet for Floors 1–2 and 65 feet for Floors 3+. Proposed: Building depth of 
approximately 230’-7” feet along the Main Street frontage. 
 
A. Special Circumstances Applicable to the Property. The site is a corner lot with two primary street 
frontages, both functioning as building fronts with entrances and active uses. Applying footprint limits 
linearly along Main Street alone disproportionately penalizes corner-lot development. 
 
B. Pre-Existing Nature of the Special Circumstances. The parcel configuration, block length, and lack of 
alley access are long-standing conditions inherent to the site. 
 
C. Deprivation of Privileges Enjoyed by Other Properties. Mid-block properties with single frontages can 
comply with footprint standards without sacrificing program functionality. Without the variance, this 
site could not support a hotel program comparable to others in the same district. 
 
D. No Grant of Special Privilege. The development remains within allowable height and density limits and 
mitigates massing through façade articulation and modulation consistent with the Form-Based Code. 
 
 
Variance 3 – Mid-Rise Building Type: Courtyard Width (MZO §11-59-13(H)) 
Required: Courtyard width between 20 and 50 feet. Proposed: Approximately 60 feet. 
 
A. Special Circumstances Applicable to the Property. The courtyard must accommodate required fire 
access, service circulation, and usable outdoor space due to the absence of alley access and the site’s 
downtown block configuration. 
 
B. Pre-Existing Nature of the Special Circumstances. These requirements arise from the parcel’s 
configuration and City safety standards. 
 
C. Deprivation of Privileges Enjoyed by Other Properties. Strict enforcement would reduce courtyard 
functionality compared to similar downtown developments.

Page 4 
 
 
 
 
D. No Grant of Special Privilege. The courtyard remains internal, landscaped, and screened, improving 
light, air, and usability without increasing density or external impacts. 
 
Variance 4 – Private Frontage: Main Street Shopfront and Dooryard Standards (MZO §§11-60-8(B) and 11-60-
9(B)) 
Requested relief from shopfront and dooryard frontage dimensions, glazing spacing, and transparency 
standards along Main Street. 
 
A. Special Circumstances Applicable to the Property. The property comprises a large, consolidated 
downtown infill site with an extended Main Street frontage and corner-lot configuration. The Form-
Based Code’s private frontage standards are applied uniformly but are calibrated for smaller, 
incremental parcels. Applied to this site, strict adherence would constrain ground-floor functionality 
needed to integrate active uses, vertical circulation, structural systems, and hotel operations. 
 
B. Pre-Existing Nature of the Special Circumstances. The size, shape, frontage length, and urban context 
of the site are pre-existing conditions established prior to adoption of the Form-Based Code. 
 
C. Deprivation of Privileges Enjoyed by Other Properties. Properties without similar frontage length and 
block configuration can comply with standards without comparable impacts. Strict application would 
deprive this site of redevelopment opportunities enjoyed elsewhere in the district. 
 
D. No Grant of Special Privilege. The Main Street frontage remains pedestrian-oriented through 
articulation, materials, and active ground-floor uses consistent with surrounding downtown 
development 
. 
 
Variance 5 – Private Frontage Types: Dooryard (Main Street) and Shopfront (Centennial Way) (MZO §§11-60-
8(B) and 11-60-9(B)) 
Required: Dooryard length limited to 50 feet with 50% transparency; shopfront glazing spacing maximum of 2 
feet; recessed entries limited to 5 feet. Proposed: Dooryard length of approximately 131 feet with 
approximately 32% transparency; shopfront glazing spacing of approximately 24 feet; recessed entry depth of 
approximately 10’-6”. 
 
A. Special Circumstances Applicable to the Property. City requirements establish the lowest finished floor 
elevation a minimum of 12 inches above adjacent top-of-curb or the 100-year storm elevation. For this 
site, the LFF is 1240.67 feet (40.67 feet per survey), while the adjacent Centennial Way top-of-curb 
elevation is approximately 39.21 feet. This elevation difference requires an ADA-compliant ramp at the 
primary Centennial Way entrance, necessitating a deeper recessed entry and affecting storefront 
glazing frequency. 
 
B. Pre-Existing Nature of the Special Circumstances. The existing storm drain infrastructure, finished floor 
elevation requirements, and public right-of-way elevations are pre-existing conditions not created by 
the applicant. 
 
C. Deprivation of Privileges Enjoyed by Other Properties. Strict application of the frontage standards 
without accounting for mandated elevation and accessibility requirements would prevent a compliant 
and legible hotel entry, limiting development potential relative to other downtown sites. 
 
D. No Grant of Special Privilege. Despite deviations from dimensional standards, the project maintains 
pedestrian activation through canopies, lighting, landscaping, and active interior uses. The variance 
enables compliance with City engineering and accessibility standards without granting a special 
privilege.