Extracted text (via ocr_local)
3515 characters
TS PER FLOOR PLAN SCALE: 1/4" 45'-0" 11-6 1/2” | 21'-0" 11-6 1/2” 12'-0” Hwaotye 7-1 1/4" 7-1 1/4" 9-7 1/2” 3'-6" + t + ~ | EC, ALATFORIM \ ABOVE a = SS a Ne 9 N 2 x7 WALLS — INFILL 6° \L STUDS L_ . : - L ~ ©} S| ee" oc w/ # Gre BO INT SIDE © v % OSB W/ 6 MIL VAPOR BARRIER . ray aN FILL WALLS W/ R19 BATT INSUL ro) = . AS REQ'D — SEE ELEVATIONS FOR EXT 9 L be) WALL MATERIALS (TYP.) io 2 x ~ | In. WALLS - 6” oR 3 §” MTL STUDS an + | —T @ 16" OC W/ 3" GYP BD EACH SIDE to FILL WALLS W/ R11 SOUND BATT INSUL AS REQ'D (TYP.) = | 4 = HH - _ : :t \ © | PRELIMINARY CODE INFO \ NOTE: CODE INFO IS BASED ON 2012 IBC. VERIFY ACTUAL CODE REQUIRE! | AUTHORITY HAVING JURISDICTION (AHJ) AS REQ'D AND ADJUST ACCORDINGLY. 4 | (2) |occuraoy = croup p susiness bo 5 J R&4.0) |MAXIMUM FLOOR AREA ALLOWED = 9,000 SF PER STORY r} | MAXIMUM STORIES ALLOWED = 2, STORIES ‘© ‘io \ MAXIMUM BUILDING HEIGHT = 40° Ne CENTER | PROPOSED CONSTRUCTION TYPE =TYPE VB UNPROTECTED, UNSPRINKLERED = r--/== | SPRINKLER SYSTEM NOT REQUIRED 7 -—- O a FIRE RESISTANCE RATINGS REQUIREMENTS = TYPE VB 0 HR FIRE RATINGS > | : FIRE SEPARATION DISTANCE RATING REQUIREMENTS = TYPE VB >10’ = 0 HR a Ge Ra 59" INTERACTVE \ > (VERIFY PLANNING/ZONING MAXIMUM FLOOR AREA, HEIGHTS, ETC. PER AHUJ) TQUCHBOARD Za I = | ° + 4 - = - - aS > + == j lif By GENERAL NOTES . 5 TECNNOLOGY/MEDIA | T. ALL DMENSIONS ARE TO FACE OF CON BLOGK, OR FACE OF STUD, UNLESS | DIBPLAY CENTER OTHERWISE NOTED. "CLEAR" DENOTES FINISH TO FINISH DIMENSONS 2. GLAZING IN DOORS AND ADJACENT PANELS MUST BE TEMPERED. GLASS IN (1) HOUR I | DESIGN | | fine RATED PART TIONS MUST.BS LAMINATED ° N _ PT 3. ALL WOOD BLOCKING, NAILERS, ETC. MUST BE FIRE RETARDANT TREATED. NEMS u }4. PROVIDE WATER RESISTANT GYP. BD. AT ALL WET LOCATIONS | H | SFL ALL CMU. WALLS BELOW GRADE. WITH CONCRETE | | DESIGN WORK: i i ti 6. ALL DETAILS OF CONSTRUCTION SHALL CONFORM WITH THE 2012 EDITION OF THE % z Zs / I 7 INTERNATIONAL BUILDING CODE & 2012 | CODE SERIES MECHANICAL, ELECTRICAL, 9 (SAMPLES /PROCHURES/INFO,) HH | I! | PLUMBING, 2012 INTERNATIONAL FIRE CODE, 2011 NATIONAL ELECTRIC CODE % | Hy ee \|— & LOCAL 'AHJ ACCESSIBILITY STANDARDS 2 . ro ct 7. CONTRACTOR TO VERIFY ALL EXIST. CONDITIONS AND DIMENSIONS PRIOR TO | | | NFOR MATION ---J | CONSTRUCTION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. | i TAT 8. ALL LIGHTS ARE TO BE SWITCHED W FINAL LOCATIONS CHOSEN BY OWNER. RFRSEAMNTS: STATIO, \ 9. INSTALL ALL FIRE ALARMS AS REQ'D PER CODE | | GATHERING UC) UC} + = = | [PROJECT INFO: | WINDOW SSs27 Se SPACE DATA: a _ _ _ = te = : | _ OPERATIONS CENTER = 6 WORKSPACES os a (ADJUSTABLE TO 8 WORKSPACES) | _ | | | | | MEN'S BATHROOM = FIXTURES LINE OF ROOF | es | eee | WOMEN'S BATHROOM = 1 FIXTURES OVERHANG an en ee ee CONFERENCE ROOM 4 SEATS © a CONFERENCE ROOM 8 SEATS - CASUAL MEETING ROOM = 5 SEATS > LINE OF ROO} E a OVERHANG T_ARI TIMBER OR HBS = a METAL OR TIMBER OPERATIONS CENTER= 677 SF COLUMN & BEAIT SUNSHADE SCREEN DESIGN CENTER= 428 SF lan CONFERENCE /MEETING SPACE= 359. SF. SUPPORT= 476 SF 4.9) CIRCULATION= 149 SF a TOTAL PROJECT AREA = 2,089 SF || 23'-0 3/a'[ UJ 20°-8 1/4” 45'-0" ss 2é oe a ef Z328e8 SZ S04 BORSS Mez5es ae E425 2*3 zen 6 pase igi Spa°2 <Gzo82% BI obs mic) 5 4 \e8 %es OM Seo 2a bz nS Ae SITE LOCATION TO BE DETERMINED CLAYTON RETAIL GROUP A NEW PROJECT FOR: z a FOR REVIEW ONLY FOR PERMITTING ONLY SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS cosoo Drawing Title: FIRST FLOOR PLAN Sheet: Sheet No. of PALA