TS PER

FLOOR PLAN

SCALE: 1/4"

45'-0"
11-6 1/2” | 21'-0" 11-6 1/2”
12'-0” Hwaotye 7-1 1/4" 7-1 1/4" 9-7 1/2” 3'-6"
+ t +
~ | EC, ALATFORIM
\ ABOVE
a = SS
a
Ne
9
N 2 x7 WALLS — INFILL 6° \L STUDS
L_ . : - L
~ ©} S| ee" oc w/ # Gre BO INT SIDE ©
v % OSB W/ 6 MIL VAPOR BARRIER
. ray aN FILL WALLS W/ R19 BATT INSUL
ro) = . AS REQ'D — SEE ELEVATIONS FOR EXT
9 L be) WALL MATERIALS (TYP.)
io
2 x
~ | In. WALLS - 6” oR 3 §” MTL STUDS
an + | —T @ 16" OC W/ 3" GYP BD EACH SIDE
to FILL WALLS W/ R11 SOUND BATT INSUL
AS REQ'D (TYP.)
= |
4 = HH -
_ :
:t \
©
| PRELIMINARY CODE INFO
\ NOTE: CODE INFO IS BASED ON 2012 IBC. VERIFY ACTUAL CODE REQUIRE!
| AUTHORITY HAVING JURISDICTION (AHJ) AS REQ'D AND ADJUST ACCORDINGLY.
4 | (2) |occuraoy = croup p susiness
bo 5 J R&4.0) |MAXIMUM FLOOR AREA ALLOWED = 9,000 SF PER STORY
r} | MAXIMUM STORIES ALLOWED = 2, STORIES
‘© ‘io \ MAXIMUM BUILDING HEIGHT = 40°
Ne CENTER | PROPOSED CONSTRUCTION TYPE =TYPE VB UNPROTECTED, UNSPRINKLERED
= r--/== | SPRINKLER SYSTEM NOT REQUIRED
7 -—- O a FIRE RESISTANCE RATINGS REQUIREMENTS = TYPE VB 0 HR FIRE RATINGS
> | : FIRE SEPARATION DISTANCE RATING REQUIREMENTS = TYPE VB >10’ = 0 HR
a Ge Ra
59" INTERACTVE \ > (VERIFY PLANNING/ZONING MAXIMUM FLOOR AREA, HEIGHTS, ETC. PER AHUJ)
TQUCHBOARD Za I = | °
+ 4 - = - - aS > + ==
j lif By GENERAL NOTES
. 5
TECNNOLOGY/MEDIA | T. ALL DMENSIONS ARE TO FACE OF CON BLOGK, OR FACE OF STUD, UNLESS
| DIBPLAY CENTER OTHERWISE NOTED. "CLEAR" DENOTES FINISH TO FINISH DIMENSONS
2. GLAZING IN DOORS AND ADJACENT PANELS MUST BE TEMPERED. GLASS IN (1) HOUR
I | DESIGN | | fine RATED PART TIONS MUST.BS LAMINATED °
N _ PT 3. ALL WOOD BLOCKING, NAILERS, ETC. MUST BE FIRE RETARDANT TREATED.
NEMS u }4. PROVIDE WATER RESISTANT GYP. BD. AT ALL WET LOCATIONS
| H | SFL ALL CMU. WALLS BELOW GRADE. WITH CONCRETE
| | DESIGN WORK: i i ti 6. ALL DETAILS OF CONSTRUCTION SHALL CONFORM WITH THE 2012 EDITION OF THE
% z Zs / I 7 INTERNATIONAL BUILDING CODE & 2012 | CODE SERIES MECHANICAL, ELECTRICAL,
9 (SAMPLES /PROCHURES/INFO,) HH | I! | PLUMBING, 2012 INTERNATIONAL FIRE CODE, 2011 NATIONAL ELECTRIC CODE
% | Hy ee \|— & LOCAL 'AHJ ACCESSIBILITY STANDARDS
2 . ro ct 7. CONTRACTOR TO VERIFY ALL EXIST. CONDITIONS AND DIMENSIONS PRIOR TO
| | | NFOR MATION ---J | CONSTRUCTION AND NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.
| i TAT 8. ALL LIGHTS ARE TO BE SWITCHED W FINAL LOCATIONS CHOSEN BY OWNER.
RFRSEAMNTS: STATIO, \ 9. INSTALL ALL FIRE ALARMS AS REQ'D PER CODE
| | GATHERING UC) UC} +
= = | [PROJECT INFO:
| WINDOW SSs27 Se SPACE DATA:
a _ _ _ = te = : | _ OPERATIONS CENTER = 6 WORKSPACES
os a (ADJUSTABLE TO 8 WORKSPACES)
| _ | | | | | MEN'S BATHROOM = FIXTURES
LINE OF ROOF | es | eee | WOMEN'S BATHROOM = 1 FIXTURES
OVERHANG an en ee ee CONFERENCE ROOM 4 SEATS
© a CONFERENCE ROOM 8 SEATS
- CASUAL MEETING ROOM = 5 SEATS
> LINE OF ROO}
E a OVERHANG
T_ARI
TIMBER OR HBS = a METAL OR TIMBER OPERATIONS CENTER= 677 SF
COLUMN & BEAIT SUNSHADE SCREEN DESIGN CENTER= 428 SF
lan CONFERENCE /MEETING SPACE= 359. SF.
SUPPORT= 476 SF
4.9) CIRCULATION= 149 SF
a
TOTAL PROJECT AREA = 2,089 SF
|| 23'-0 3/a'[ UJ 20°-8 1/4”
45'-0"

ss

2é

oe

a ef
Z328e8
SZ S04
BORSS
Mez5es
ae
E425 2*3
zen 6
pase igi
Spa°2
<Gzo82%
BI obs
mic) 5
4 \e8 %es
OM Seo
2a

bz

nS

Ae

SITE LOCATION
TO BE DETERMINED

CLAYTON RETAIL GROUP

A NEW PROJECT FOR:

z
a

FOR REVIEW ONLY
FOR PERMITTING ONLY
SCHEMATIC DESIGN

DESIGN DEVELOPMENT
CONSTRUCTION DOCUMENTS

cosoo

Drawing Title:

FIRST FLOOR PLAN

Sheet: Sheet No.