Extracted text (via pymupdf)
104439 characters
ELUX AT MCQUEEN DECEMBER 2020 Planned Area Development Preliminary Development Plan & Preliminary Plat A SNOWDEN COMMUNITY PAD/ PDP CASE NO.: PLH19-0063 PRE-PLAT CASE NO.: PLT19-0055 1ST SUBMITTAL: NOVEMBER 15, 2019 2ND SUBMITTAL: OCTOBER 29, 2020 REVISED 2ND SUBMITTAL: DECEMBER 14, 2020 i ELUX AT MCQUEEN Andy Baron, ASLA, LEED AP 310 E. Rio Salado Parkway Tempe, AZ 85281 P: (480) 530-0077 andy.baron@ablastudio.com Snowdon McQueen, LLC Michael Vucekovish 7114 E. Stetson Drive, Suite 400 Scottsdale, AZ michael@snowdonpartners.com DEVELOPER: PROJECT TEAM: PROJECT INFORMATION: Brennan Ray 1850 N. Central Avenue, Suite 1700 Phoenix, AZ 85004 P: (602) 274-7611 bray@bcattorneys.com Nick Prodanov 8808 N. Central Avenue, Suite 288 Phoenix, AZ 85020 P: (602) 889-1984 nick@ldgeng.com Project Location: Request: General Plan Designation: Air Park Area Plan: Existing Zoning: Proposed Zoning: Existing Use: Gross Area: Net Area: Maximum Proposed Dwelling Units: Maximum Proposed Density: Open Space: Southeast corner of McQueen Road and the Loop 202 San Tan Freeway Planned Area Development (PAD), Preliminary Development Plan (PDP), & Preliminary Plat (PPT) PAD/ PDP Case No. PLH19-0063 PPT Case No. PLT19-0055 Neighborhoods High Density Residential (HDR) (12.1-18.0 du/ac) AG-1 Planned Area Development (PAD) Vacant 13.90 Ac. 12.87 Ac. 162 Du. 12.59 Du./Ac. 3.95 Ac. (30.80% of Net) Lance Baker 1111 W. University Drive, Suite 104 Tempe, AZ 85281 P: (480) 663-2100 lbaker@sdiaz.us 1 Introduction 1 2 Background 1 3 Request 1 4 General Plan & Area Plan Compliance 1 5 Planned Area Development 2 6 Housing Product 3 7 Proposed Development Standards 4 8 Parking & Refuse 4 9 Grading and Drainage 4 10 Infrastructure Analysis 4 11 Preliminary Plat 4 12 Conclusion 5 Exhibit A: Vicinity Map 6 Exhibit B: Existing & Proposed Zoning Map 7 Exhibit C: General Plan Land Use Map 8 Exhibit D: Chandler Airpark Area Plan 9 Exhibit E: Development Plan 10 Exhibit F: Landscape Plan 13 Exhibit G: Open Space Plan 14 Exhibit H: Amenity Plan 15 Exhibit I: Pedestrian Circulation Plan 17 Exhibit J: Wall Plan 18 Exhibit K: Wall Details 19 Exhibit L: Entry Plan & Details 20 Exhibit M: Entry Monuments 21 Exhibit N: Aircraft Warning Sign Plan 22 Exhibit O: Illustrative Rendering 23 Exhibit P: Elevations & Floor Plans 25 Exhibit Q: Street Sections 50 Exhibit R: Parking & Trash Location Plan 51 Exhibit S: Preliminary Grading & Drainage Plan 52 Exhibit T: Preliminary Plat 53 Exhibit U: Southern Boundary Cross Section 54 ii ELUX AT MCQUEEN TABLE OF CONTENTS: LIST OF EXHIBITS: 1 Introduction Snowdon McQueen LLC is excited to bring ELUX at McQueen, an approximately 13.90-gross acre (12.87- net acre) community located in the City of Chandler (the “City”) at the southeast corner of McQueen Road and the Loop 202 Santan Freeway. The housing product designed for ELUX at McQueen is relatively unique to the region and was developed through a creative research and development process. Snowdon McQueen LLC intends for the ELUX at McQueen (or the “Site”) development to become a point of pride within the City, offering a distinct housing product and a uniquely themed community for current and future residents of the City of Chandler (See Exhibit A: Vicinity Map). ELUX at McQueen is an ideally located residential development situated approximately two miles northwest of the Chandler Municipal Airport (the “Airport”), and adjacent to employment, commercial, recreational, municipal, and residential uses. The proximity of the Site to shopping and employment allows for the creation of a unique environment that responds to the housing needs of the surrounding area. ELUX at McQueen is anticipated to have one-hundred and sixty-two (162) single-family detached and attached units in a for rent community at an overall net density of approximately 12.59 du/ac. This Site is an appropriate location to introduce this unique housing product and community. The proposed architectural character for ELUX at McQueen reflects the character of the vibrant and growing City. Additionally, throughout the community, thematic architectural and landscape elements will be designed and implemented to celebrate the modern, unique product and related land uses in the surrounding area. The quality and proposed aesthetics of ELUX at McQueen reflects Snowdon McQueen LLC’s commitment to progressive community design and development. 2 Background This project is proposing that approximately 13.90 gross acres be rezoned from AG-1 to PAD for a unique and high-quality residential development (See Exhibit B: Existing & Proposed Zoning Map). Simultaneous with the Rezoning request, this development is seeking a PDP approval for the site plan consisting of 162 detached and attached single-family for rent units. The proposed development is planned as a gated community and is planned to accommodate a net density of approximately 12.59 du/ac. This development meets the goals, policies, and intent of the General Plan and Area Plan, and is compatible with neighboring developments while providing an attractive presence in the area. 3 Request In order to achieve this development on the Site, Snowdon McQueen LLC is requesting: • The Site to be rezoned from AG-1 to Planned Area Development (PAD) for Residential; • Approval of the Preliminary Development Plan (PDP); and, • Approval of the Preliminary Plat (PPT). 4 General Plan & Area Plan Compliance The City of Chandler General Plan designates the Site as Neighborhoods (See Exhibit C: General Plan Land Use Map). The Site’s development as a single-family for rent community is consistent with the underlying General Plan land use designation of Neighborhoods. Given that the Site is located adjacent to employment uses to the west, the Santan Freeway to the north, and medium density housing to the 1 ELUX AT MCQUEEN east, and is in close proximity to the Airport and a future transit center at Arizona Avenue and Germann Road, high density housing is appropriate on the Site. Further, much of the immediate area has either been developed or is currently being developed with a variety of single-family residential densities. The Site is also located within the Chandler Airpark Area Plan, which designates the Site as High Density Residential (HDR) (12.1-18 du/ac) (See Exhibit D: Chandler Airpark Area Plan). The Site is proposed to have 162 units at 12.59 du/net acre which is consistent with the Chandler Airpark designation of HDR. The proposed development also incorporates a different product type in a for rent setting, which creates a diverse housing market without introducing a development so different as to be inappropriate or incompatible with the existing neighborhoods. The proposed architectural style and enhanced landscape elements will bring aesthetic diversity to the area with a unique yet authentic character. 5 Planned Area Development The Site is currently zoned AG-1 and Snowdon McQueen LLC is requesting the Site be rezoned to PAD for residential uses and will adhere to the development standards stated herein. ELUX at McQueen will be a unique housing type promoting connectivity within the community and offering clubhouse amenities for residents. Complementary architectural style and details will be utilized throughout the community. The proposed Development Plan will establish a community with pedestrian courtyards, private rear yards, and community amenities (See Exhibit E: Development Plan and Exhibit F: Landscape Plan). ELUX at McQueen will include a total of 162 residences at a net density of approximately 12.59 dwelling units per acre. The southern boundary of the site adjacent to existing development has been designed to include additional buffering between existing single-family residences and proposed units. The Site provides approximately 3.95 acres of open space, or 30.80% of the total development’s net acreage (See Exhibit G: Open Space Plan). The open space has been dispersed throughout the Site to provide efficient retention as well as visual relief across the development. A 3,624 square-foot community clubhouse amenity is prominently featured within the community amenity area. The amenity area includes the clubhouse building, pool and spa, cabanas, barbeque, and seating areas. This amenity area will be easily accessible to all the residents of ELUX at McQueen via a six-foot (6’) centralized sidewalk, supporting recreational activity and social interaction. As a major component of the community’s identity, the clubhouse will complement the modern architectural style of the homes by using tile cladding, metal work on doors and windows, tempered glazing windows, and stucco finishes. Additionally, a second amenity area is provided on the eastern end of the development and includes a pickle ball court as well as shade features, turf areas, and site furnishings (See Exhibit H: Amenity Plan). This area is accessed by three (3), four (4), and five-foot (5’) sidewalks surrounding and internal to the amenity. The community will have various sidewalks and pathways connecting residents to their homes, parking areas, open spaces, and community amenities and clubhouse (See Exhibit I: Pedestrian Circulation Plan). The interior and exterior landscape theming of ELUX at McQueen will feature modern design elements and motifs which will help reflect the community’s distinct style while maintaining an aesthetic balance with the surrounding area. The design of the perimeter walls will reflect the quality and character of the community (See Exhibit J: Wall Plan and Exhibit K: Wall Details). The primary gated entrance into the community is located off of McQueen Road. The community entrance will include a monument sign, accentuated with enhanced ornamental desert plantings organized in formal massings and patterns. A secondary access point for the community is proposed at the southeast corner of the development, connecting to Senate Street and Armstrong Way. Both the primary and secondary entryways will incorporate design elements such as CMU block raised planters, CMU block with stucco finishes, precast concrete caps, aluminum channel, and reverse pan channel lettering, to create a cohesive design (See 2 ELUX AT MCQUEEN Exhibit L: Entry Plan & Details and Exhibit M: Entry Monuments). At the main entryway and at various points throughout the Site, low flying aircraft warning signs will be prominently displayed for residents and visitors (see Exhibit N: Aircraft Warning Sign Plan). 6 Housing Product The ELUX at McQueen development is a single-family for rent product that lives like a traditional single- family residential home. These casita-style homes address the needs of modern families. The homes will be built with energy-efficient and sustainable construction technology. The proposed design of the development consists of 162 one and two-story, detached and attached residences to create a community that is attractively designed, aesthetically landscaped, and provides an appropriate use for the Site. The proposed development is planned as a gated community that will consist of approximately 162 residences at a net density of approximately 12.59 du/ac. The residences are a mix of one, two, and three bedrooms, with an appropriate mix of the residences being detached and attached in a duplex style. Unlike traditional apartment complexes, where most units are one and two bedrooms (typically 50-60% one bedrooms, 30-40% two bedrooms, and less than 10% three bedrooms), this project has an increased number of two- and three-bedroom residences (40% one bedrooms, 40 % two bedrooms, and 20% three bedrooms). The residences are predominately grouped around pedestrian courtyards to create a sense of arrival, place, and connectivity within the greater context of the community (See Exhibit O: Illustrative Rendering). A unique feature is that every residence includes a private, enclosed rear yard which, in most cases, is nearly as wide as the residence itself. Small-scale pedestrian courtyards and outdoor seating areas are also provided to create a seamless and smooth transition between public and private portions of the community. The amenity areas are designed to enhance the community identity and the quality of life of the residents by providing recreational opportunities and connectivity through the integration of effective and accessible internal open spaces. The amenity and theming elements have been integrated to maintain the overall character of the community. The primary amenity area (located at the southwest corner of the Site) will include a resort-style swimming pool and spa, seating areas for residents to relax and socialize, and a clubhouse with restroom facilities and resident amenities. The product proposed for this Site represents a lifestyle choice, presenting future residents a unique living experience and an alternative housing choice to the traditional options of single-family residences or apartment complexes. This development combines the best elements of residential single-family living with multi-family-like lease terms and management. The combination of these elements creates a desirable residential option with upscale features and spacious indoor/outdoor living areas maintained by a professional management company, without the expense or HOA fees of a typical single-family development. The casita-style residences include one and two-story options, with many containing no more than one unit per building, creating a “single-family subdivision” feel throughout the development. Due to the design of the ELUX at McQueen community, attached garages will not be provided for all units. Detached garages and covered parking spaces will be provided and internalized and screened from adjacent roadways. The garage elevations incorporate similar elements from the residence buildings to create a consistent design throughout the community. Parking canopy covers will be consistent with the building colors and will be architecturally integrated with the surrounding structures. 3 ELUX AT MCQUEEN 7 Proposed Development Standards The following development standards are proposed for ELUX at McQueen: Single-Family For Rent / Condo Plat PERIMETER BUILDING SETBACKS (SETBACKS SHOWN ARE MINIMUM REQUIREMENTS) SINGLE-FAMILY FOR RENT PRODUCT Adjacent to McQueen Road 50’ Adjacent to Loop 202 Freeway 10’ Adjacent to single-family uses 35’ Adjacent to multi-family uses 10’ INTERIOR BUILDING SETBACKS (SETBACKS SHOWN ARE MEASURED FROM PROPERTY LINE TO BUILDING FOUNDATION, UNLESS OTHERWISE STATED) Side 0’ Separation between principal buildings (min.) 6’ BUILDING STANDARDS Building height (max.) 2-stories, 30’ Lot Coverage (max.) 40% (See Exhibit P: Elevations & Floor Plans) 8 Parking & Refuse The ELUX at McQueen development provides 327 parking spaces. Of the 327 parking spaces, 77 will be enclosed garage spaces that reduce the visual impact and scale of the parking spaces. The garages also provide a buffer for the property against the Loop 202 to the north. Refuse enclosures are distributed throughout the Site (See Exhibit Q: Street Sections and Exhibit R: Parking & Trash Location Plan). 9 Grading and Drainage There are no offsite flows that historically pass through the Site. The adjacent offsite streets and internal onsite streets will convey storm water to multiple surface retention basins and underground retention (See Exhibit S: Preliminary Grading & Drainage Plan). 10 Infrastructure Analysis Onsite water and sewer mains will be private. A potable meter with a looped private water line will connect at McQueen Road and Senate Street. The 8” stub along McQueen Road will be utilized for sewer connection, and water service will be provided by the City of Chandler. Sewer service will also be provided by the City of Chandler. 11 Preliminary Plat See Exhibit T: Preliminary Plat. 4 ELUX AT MCQUEEN 12 Conclusion ELUX at McQueen will be a high quality, sustainable, and dynamic development on this Site. The proposed PAD and PDP meet the goals of the City by providing a vibrant community that is visually attractive and provides a unique single-family for rent product. Further, ELUX at McQueen will provide additional support to the existing and planned retail and employment uses in the area. ELUX at McQueen is a project that incorporates a compatible transitioning density. The proposed clubhouse, outdoor amenities, and courtyard- style layouts will help to create a close community by providing a creative space for families, friends and neighbors to enjoy together. Cohesive pedestrian connectivity throughout the development reinforces a desirable lifestyle and embraces place-making principles. A community with tasteful modern architectural design and themes that complement the surrounding developments, assures that ELUX at McQueen will be a valuable asset to the City and immediate area. The development also creates visual interest on the perimeter through an attractive perimeter wall, architectural facades, a creatively designed entryway, and a well-planned open space and amenity area. We request your approval. 5 ELUX AT MCQUEEN ELUX AT MCQUEEN 6 Exhibit A: VICINITY MAP N ELUX AT MCQUEEN 7 Exhibit B: EXISTING & PROPOSED ZONING MAP N ELUX AT MCQUEEN 8 Exhibit C: GENERAL PLAN LAND USE MAP N ELUX AT MCQUEEN 9 Exhibit D: CHANDLER AIRPARK AREA PLAN N ELUX AT MCQUEEN 10 Exhibit E: DEVELOPMENT PLAN N ELUX AT MCQUEEN 11 DEVELOPMENT PLAN N ELUX AT MCQUEEN 12 DEVELOPMENT PLAN N ELUX AT MCQUEEN 13 Exhibit F: LANDSCAPE PLAN N ELUX AT MCQUEEN 14 Exhibit G: OPEN SPACE PLAN N ELUX AT MCQUEEN 15 Exhibit H: AMENITY PLAN N ELUX AT MCQUEEN 16 AMENITY PLAN N ELUX AT MCQUEEN 17 Exhibit I: PEDESTRIAN CIRCULATION PLAN N ELUX AT MCQUEEN 18 Exhibit J: WALL PLAN N ELUX AT MCQUEEN 19 Exhibit K: WALL DETAILS ELUX AT MCQUEEN 20 Exhibit L: ENTRY PLAN & DETAILS ELUX AT MCQUEEN 21 Exhibit M: ENTRY MONUMENTS ELUX AT MCQUEEN 22 Exhibit N: AIRCRAFT WARNING SIGN PLAN N ELUX AT MCQUEEN 23 Exhibit O: ILLUSTRATIVE RENDERING ELUX AT MCQUEEN 24 ILLUSTRATIVE RENDERING ELUX AT MCQUEEN 25 Exhibit P: ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES SHEET KEYED NOTES First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" T.O. Parapet 16' - 6" 14 3 A7.1 TYP D-4 A 01- 8 2 3 4 12 C-3 D C B C RTU D TYP. 1' - 6" C B RTU D D C A G First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" T.O. Parapet 16' - 6" D 13' - 7" 2' - 11" 3 A7.1 TYP 5 A7.1 TYP 4 A7.1 TYP B-2 A-1 D 11 12 4 3 C C A D A A C A C C G First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" T.O. Parapet 16' - 6" 1' - 11" E-6 E-5 B 02- 1 2 3 12 4 9 ? C TYP. 1' - 6" PANEL METER RTU B 11 SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" T.O. Parapet 16' - 6" C 16' - 6" TYP. 1' - 6" RTU SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP NYK LDB 4014 2020-10-22 EXTERIOR ELEVATIONS UNIT TYPE A-DUPLEX A3.1 2020-07-28 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 2 FIRE ALARM BELL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 3 WALL MOUNTED EXTERIOR PORCH OR PATIO LIGHT FIXTURE, SEE ID, AND ELECTRICAL SHEETS 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 8 BUILDING ADDRESS SEE ARCHITECTURAL SITE PLAN 9 THICKENED RIGID INSULATION ADDITIONAL 1-1/2" TYP WITH HORIZONTAL V REVEAL TYP 11 STUCCO CONTROL JOINT SEE 5/A7.1 12 STUCCO V REVEL SEE 4/A7.1 14 LINE OF ROOF BEYOND 1/4" = 1'-0" 1 Front Elevation 1/4" = 1'-0" 3 Back Elevation 1/4" = 1'-0" 2 Right Side Elevation 1/4" = 1'-0" 4 Left Side Elevation FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASCIA TBD METALWOOD BRONZE - SMOOTH C STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 - SAND FINISH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS, AND WINDOWS DE DUNN EDWARDS DE6370 - CHARCOAL SMUDGE F GLAZING TBD CLEAR LOW-E G FLAT CONCRETE ROOF TILES EAGLE 4503 SIERRA MADRE ELUX AT MCQUEEN 26 ELUX AT MCQUEEN 27 ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES SHEET KEYED NOTES First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" T.O. Parapet 16' - 6" 14 3 A7.1 TYP D-4 A 01- 8 2 3 4 0020 C-3 D C B C RTU D TYP. 1' - 6" G First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" T.O. Parapet 16' - 6" D 13' - 7" 2' - 11" 3 A7.1 TYP 5 A7.1 TYP 4 A7.1 TYP B-2 A-1 D 11 12 4 3 C C A G First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" T.O. Parapet 16' - 6" 1' - 11" E-6 E-5 A 02- 1 2 3 12 4 9 C TYP. 1' - 6" PANEL METER RTU B 11 SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" T.O. Parapet 16' - 6" A 3 A7.1 TYP F-7 D 12 9 4 4 C C B 13' - 7" 2' - 11" TYP. 1' - 6" RTU 12 R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 EXTERIOR ELEVATIONS UNIT TYPE A A3.1 2020-07-28 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 2 FIRE ALARM BELL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 3 WALL MOUNTED EXTERIOR PORCH OR PATIO LIGHT FIXTURE, SEE ID, AND ELECTRICAL SHEETS 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 8 BUILDING ADDRESS SEE ARCHITECTURAL SITE PLAN 9 THICKENED RIGID INSULATION ADDITIONAL 1-1/2" TYP WITH HORIZONTAL V REVEAL TYP 11 STUCCO CONTROL JOINT SEE 5/A7.1 12 STUCCO V REVEL SEE 4/A7.1 14 LINE OF ROOF BEYOND 00 20 1/4" = 1'-0" 1 Front Elevation 1/4" = 1'-0" 3 Back Elevation 1/4" = 1'-0" 2 Right Side Elevation 1/4" = 1'-0" 4 Left Side Elevation FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASCIA TBD METALWOOD BRONZE - SMOOTH C STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 - SAND FINISH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS, AND WINDOWS DE DUNN EDWARDS DE6370 - CHARCOAL SMUDGE F GLAZING TBD CLEAR LOW-E G FLAT CONCRETE ROOF TILES EAGLE 4503 SIERRA MADRE ELUX AT MCQUEEN 28 ELUX AT MCQUEEN 29 ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES SHEET KEYED NOTES First Floor 0" T.O. Window 8' - 0" T.O. Parapet 17' - 6" A C 1' - 6" 3 A7.1 Typ. B-4 G-3 8 4 A 2 3 C D B C C B RTU 11 11 11 C TYP. 1' - 6" C B RTU A D A C G First Floor 0" T.O. Window 8' - 0" T.O. Parapet 17' - 6" 1' - 6" 3 A7.1 Typ. F-2 A 01- 4 11 11 C B B C C A D METER PANEL 3 2 1 D 7 3 11 RTU SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. First Floor 0" T.O. Window 8' - 0" T.O. Parapet 17' - 6" 3 A7.1 Typ. A-1 F 02- 11 11 4 D C B C 7 10 10 B 3 RTU D A A A A A B G First Floor 0" T.O. Window 8' - 0" T.O. Parapet 17' - 6" RTU B C ? TYP. 1' - 6" A D A D C C B R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP NYK LDB 4014 2020-10-22 EXTERIOR ELEVATIONS UNIT TYPE B DUPLEX A3.3 2020-07-28 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 2 FIRE ALARM BELL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 3 WALL MOUNTED EXTERIOR PORCH OR PATIO LIGHT FIXTURE, SEE ID, AND ELECTRICAL SHEETS 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 7 SHADE CANOPY SLOPE AWAY FROM BUILDING (MIN. 1/4" / 12") 8 BUILDING ADDRESS SEE ARCHITECTURAL SITE PLAN 10 PRE-FINISHED METAL PARAPET CAP TYPICAL 11 STUCCO CONTROL JOINT SEE 5/A7.1 1/4" = 1'-0" 1 Front Elevation 1/4" = 1'-0" 2 Right Side Elevation 1/4" = 1'-0" 3 Back Elevation 1/4" = 1'-0" 4 Left Side Elevation FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASCIA TBD METALWOOD BRONZE -SMOOTH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS, AND WINDOWS DE DUNN EDWARDS DE6370 - CHARCOAL SMUDGE F GLAZING TBD CLEAR LOW-E G FLAT CONCRETE ROOF TILES EAGLE 4503 SIERRA MADRE ELUX AT MCQUEEN 30 ELUX AT MCQUEEN 31 ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES SHEET KEYED NOTES First Floor 0" T.O. Window 8' - 0" T.O. Parapet 17' - 6" A C 1' - 6" 3 A7.1 Typ. B-4 G-3 8 4 A 2 3 C D B C C B RTU 11 11 11 C TYP. 1' - 6" First Floor 0" T.O. Window 8' - 0" T.O. Parapet 17' - 6" 1' - 6" 3 A7.1 Typ. F-2 A 01- 4 11 11 C B B C C A D METER PANEL 3 2 1 D 7 3 11 SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. G First Floor 0" T.O. Window 8' - 0" T.O. Parapet 17' - 6" 3 A7.1 Typ. A-1 F 02- 11 11 4 D A C B C 7 10 10 B 3 RTU 10 First Floor 0" T.O. Window 8' - 0" T.O. Parapet 17' - 6" 1' - 6" RTU B C B C C C C D A D A 12 11 3 4 7 9 TYP. 1' - 6" G R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 EXTERIOR ELEVATIONS UNIT TYPE B A3.3 2020-07-28 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 2 FIRE ALARM BELL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 3 WALL MOUNTED EXTERIOR PORCH OR PATIO LIGHT FIXTURE, SEE ID, AND ELECTRICAL SHEETS 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 7 SHADE CANOPY SLOPE AWAY FROM BUILDING (MIN. 1/4" / 12") 8 BUILDING ADDRESS SEE ARCHITECTURAL SITE PLAN 9 THICKENED RIGID INSULATION ADDITIONAL 1-1/2" TYP WITH HORIZONTAL V REVEAL TYP 10 PRE-FINISHED METAL PARAPET CAP TYPICAL 11 STUCCO CONTROL JOINT SEE 5/A7.1 12 STUCCO V REVEL SEE 4/A7.1 1/4" = 1'-0" 1 Front Elevation 1/4" = 1'-0" 2 Right Side Elevation 1/4" = 1'-0" 3 Back Elevation 1/4" = 1'-0" 4 Left Side Elevation FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASCIA TBD METALWOOD BRONZE -SMOOTH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS, AND WINDOWS DE DUNN EDWARDS DE6370 - CHARCOAL SMUDGE F GLAZING TBD CLEAR LOW-E G FLAT CONCRETE ROOF TILES EAGLE 4503 SIERRA MADRE ELUX AT MCQUEEN 32 ELUX AT MCQUEEN 33 ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES SHEET KEYED NOTES First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" Second Floor 10' - 10 7/8" T.O. Parapet 26' - 0" Bearing HT 2nd Level 20' - 1 1/2" T.O. Window 2nd Level 18' - 10 7/8" D D C 3 A7.1 Typ. A D-8 C-3 D-4 D-4 8 4 11 D 2 11 10 11 C A A D 3 11 H-10 H-11 H-12 H-9 H-8 6' - 8" B B B A D ? D D D C C C C B G First Floor 0" T.O. Window 8' - 0" Second Floor 10' - 10 7/8" T.O. Parapet 26' - 0" Bearing HT 2nd Level 20' - 1 1/2" T.O. Window 2nd Level 18' - 10 7/8" A C C A D A B 11 12 4 RTU SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" Second Floor 10' - 10 7/8" T.O. Parapet 26' - 0" Bearing HT 2nd Level 20' - 1 1/2" T.O. Window 2nd Level 18' - 10 7/8" ? 3 A7.1 Typ. 05-F D-7 A-5 D-6 A-1 D 4 4 C C A B A 7 11 11 10 C A 11 D D A A B C G G First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" Second Floor 10' - 10 7/8" T.O. Parapet 26' - 0" Bearing HT 2nd Level 20' - 1 1/2" T.O. Window 2nd Level 18' - 10 7/8" A 3 A7.1 Typ. F-2 4 4 11 A 14 RTU D A C C B 2 1 METER PANEL 11 10 A-16 SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP NYK LDB 4014 2020-10-23 EXTERIOR ELEVATIONS UNIT TYPE C DUPLEX A3.5 2020-07-28 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 2 FIRE ALARM BELL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 3 WALL MOUNTED EXTERIOR PORCH OR PATIO LIGHT FIXTURE, SEE ID, AND ELECTRICAL SHEETS 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 7 SHADE CANOPY SLOPE AWAY FROM BUILDING (MIN. 1/4" / 12") 8 BUILDING ADDRESS SEE ARCHITECTURAL SITE PLAN 10 PRE-FINISHED METAL PARAPET CAP TYPICAL 11 STUCCO CONTROL JOINT SEE 5/A7.1 12 STUCCO V REVEL SEE 4/A7.1 14 LINE OF ROOF BEYOND 1/4" = 1'-0" 1 Front Elevation 1/4" = 1'-0" 2 Left Side Elevation 1/4" = 1'-0" 3 Rear Elevation 1/4" = 1'-0" 4 Right Side Elevation FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASCIA TBD METALWOOD BRONZE - SMOOTH C STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 - SAND FINISH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS, AND WINDOWS DE DUNN EDWARDS DE6370 - CHARCOAL SMUDGE F GLAZING TBD CLEAR LOW-E G FLAT CONCRETE ROOF TILES EAGLE 4503 SIERRA MADRE ELUX AT MCQUEEN 34 ELUX AT MCQUEEN 35 ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES SHEET KEYED NOTES First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" Second Floor 10' - 10 7/8" T.O. Parapet 26' - 0" Bearing HT 2nd Level 20' - 1 1/2" T.O. Window 2nd Level 18' - 10 7/8" D D C 3 A7.1 Typ. A D-8 C-3 D-4 D-4 8 4 11 D 2 11 10 11 C A A D 3 11 H-10 H-11 H-12 H-9 H-8 6' - 8" B B G First Floor 0" T.O. Window 8' - 0" Second Floor 10' - 10 7/8" T.O. Parapet 26' - 0" Bearing HT 2nd Level 20' - 1 1/2" T.O. Window 2nd Level 18' - 10 7/8" A A 4 4 D C C 11 11 10 13' - 1" 3' - 0" 7 10 B B First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" Second Floor 10' - 10 7/8" T.O. Parapet 26' - 0" Bearing HT 2nd Level 20' - 1 1/2" T.O. Window 2nd Level 18' - 10 7/8" D 3 A7.1 Typ. 05-F D-7 A-5 D-6 A-1 D 4 4 C C A B A 7 11 11 10 C A 11 G G First Floor 0" T.O. Window 8' - 0" Bearing HT 9' - 1 1/8" Second Floor 10' - 10 7/8" T.O. Parapet 26' - 0" Bearing HT 2nd Level 20' - 1 1/2" T.O. Window 2nd Level 18' - 10 7/8" A 3 A7.1 Typ. F-2 4 4 11 A 14 RTU D A C C B 2 1 METER PANEL 11 10 A-16 SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 EXTERIOR ELEVATIONS UNIT TYPE C A3.5 2020-07-28 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 2 FIRE ALARM BELL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 3 WALL MOUNTED EXTERIOR PORCH OR PATIO LIGHT FIXTURE, SEE ID, AND ELECTRICAL SHEETS 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 7 SHADE CANOPY SLOPE AWAY FROM BUILDING (MIN. 1/4" / 12") 8 BUILDING ADDRESS SEE ARCHITECTURAL SITE PLAN 10 PRE-FINISHED METAL PARAPET CAP TYPICAL 11 STUCCO CONTROL JOINT SEE 5/A7.1 14 LINE OF ROOF BEYOND 1/4" = 1'-0" 1 Front Elevation 1/4" = 1'-0" 2 Left Side Elevation 1/4" = 1'-0" 3 Rear Elevation 1/4" = 1'-0" 4 Right Side Elevation FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASCIA TBD METALWOOD BRONZE - SMOOTH C STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 - SAND FINISH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS, AND WINDOWS DE DUNN EDWARDS DE6370 - CHARCOAL SMUDGE F GLAZING TBD CLEAR LOW-E G FLAT CONCRETE ROOF TILES EAGLE 4503 SIERRA MADRE RTU ELUX AT MCQUEEN 36 ELUX AT MCQUEEN 37 ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" 3. TEMPERED GLAZING PANELS AT LOCATIONS INDICATED WITH T* EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES First Floor 0" Second Floor 11' - 0" T.O. Parapet 26' - 0" Window Head 19' - 0" 2nd Roof Bearing 20' - 1 1/8" 0" 2' - 0" 2' - 0" 6' - 6" C B C D C B B C B 2 A5.1D 3 A5.1D E-3 E-2 E-1 K-20 M-19 I-18 A-17 K-16 M-15 E-6 E-5 E-4 J 03- K 04- K 05- K 06- K 07- K 08- J 09- 5 A7.2D D D 3 3 12 3 E-ESCAPE 2' - 0" 2' - 8 1/2" 1' - 8" T* A A A A A C A A C D 3 12 12 12 12 10 10 1' - 0" G G First Floor 0" Second Floor 11' - 0" T.O. Parapet 26' - 0" Window Head 19' - 0" 2nd Roof Bearing 20' - 1 1/8" C A C E A 01- 12 12 B B C D C A 8' - 11" 3' - 0" 10 10 12 12 3 4 First Floor 0" Second Floor 11' - 0" T.O. Parapet 26' - 0" Window Head 19' - 0" 2nd Roof Bearing 20' - 1 1/8" 1' - 0" B E B A 01- G 12- 3 12 12 RTU C C C D A 12 12 2 4 METER PANELS 3' - 0" 8' - 11" SES METERS TO BE FULLY SCREENED WITH ENHANCED LANDSCAPE PLANTINGS. SHEET KEYED NOTES R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 EXTERIOR ELEVATIONS UNIT TYPE D A3.7 2020-07-28 1/4" = 1'-0" 1 Front Elevation 1/4" = 1'-0" 2 Left Side Elevation 1/4" = 1'-0" 4 Right Side Elevation FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASCIA TBD METALWOOD BRONZE - SMOOTH C STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 - SAND FINISH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS AND WINDOWS DE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 F GLAZING TBD CLEAR LOW-E G FLAT CONCRETE ROOF TILES EAGLE 4503 SIERRA MADRE 2 FIRE ALARM PANEL (DEFERRED SUBMITTAL) 3 WALL MOUNTED EXTERIOR PORCH OR PATIO LIGHT FIXTURE, SEE ID, AND ELECTRICAL SHEETS 4 STEEL COLUMN FOR SHADE CANOPY, SEE STRUCTURAL SHEETS 10 PRE-FINISHED METAL PARAPET CAP TYPICAL 12 STUCCO V REVEL SEE 4/A7.1 ELUX AT MCQUEEN 38 ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" 3. TEMPERED GLAZING PANELS AT LOCATIONS INDICATED WITH T* EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES First Floor 0" Second Floor 11' - 0" T.O. Parapet 26' - 0" Window Head 19' - 0" 2nd Roof Bearing 20' - 1 1/8" 1' - 0" 1' - 0" C B A A C C B 2 A5.1D 3 A5.1D J-7 J-8 A-9 D-10 H-11 H-12 J-14 F 21- F 13- 3 3 10 12 D D D A 12 E-ESCAPE 1' - 8" 2' - 8 1/2" 2' - 0" RTU B C 12 12 G SHEET KEYED NOTES R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 EXTERIOR ELEVATIONS UNIT TYPE D A3.8 2020-07-28 1/4" = 1'-0" 1 Rear Elevation 3 WALL MOUNTED EXTERIOR PORCH OR PATIO LIGHT FIXTURE, SEE ID, AND ELECTRICAL SHEETS 10 PRE-FINISHED METAL PARAPET CAP TYPICAL 12 STUCCO V REVEL SEE 4/A7.1 FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASCIA TBD METALWOOD BRONZE - SMOOTH C STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 - SAND FINISH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS AND WINDOWS DE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 F GLAZING TBD CLEAR LOW-E G FLAT CONCRETE ROOF TILES EAGLE 4503 SIERRA MADRE ELUX AT MCQUEEN 39 ELUX AT MCQUEEN 40 ELEVATIONS & FLOOR PLANS 1. SEE ARCHITECTURAL SITE PLAN FOR BUILDING ORIENTATION AND OR MIRRORING. ORIENTATION SHOWN IS FOR REFERENCE ONLY 2. SEE GRADING AND DRAINAGE PLAN FOR BUILDING ELEVATION FFE=FIRST FLOOR 0" 3. SEE SHEET A7.1E FOR TYPICAL STOREFRONT DETAILS 4. TEMPERED GLAZING PANELS AT LOCATIONS INDICATED WITH T* EXTERIOR ELEVATION GENERAL NOTES 1. ALL ROOF MOUNTED MECHANICAL EQUIPMENT SHALL BE FULLY SCREENED BY PARAPET WALLS EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT. 2. SOLID MASONRY WALLS AND GATES EQUAL TO, OR GREATER THAN, THE HIGHEST POINT ON THE MECHANICAL EQUIPMENT SHALL SCREEN ALL GROUND MOUNTED MECHANICAL EQUIPMENT. 3. ANY ROOF ACCESS LADDERS SHALL BE LOCATED INSIDE THE BUILDING. ROOF DRAINAGE SHALL UTILIZE INTERIOR ROOF DRAINS OR BE ARCHITECTURALLY INTEGRATED INTO THE BUILDING DESIGN. ARCHITECTURALLY INTEGRATED ROOF DRAINS SHALL REQUIRE ADDITIONAL ARTICULATION BEYOND PAINT ACCENTS. SECTION 35-1902 (8)(E)(15), ZONING CODE. 4. SCREENING SHALL BE ARCHITECTURALLY INTEGRATED FOR THE SERVICE ENTRANCE SECTION (SES) AND ALL UTILITIES. ALL GROUND MOUNTED EQUIPMENT SHALL BE SCREENED FROM PUBLIC VIEW BY A CONCRETE OR MASONRY WALL WITH SOLID GATES, EQUAL TO OR GREATER IN HEIGHT THAN THE MECHANICAL EQUIPMENT. SECTION 35-1902 (8)(E)13, ZONING CODE. 5. SIGNS REQUIRE A SEPARATE SUBMITTAL AND PERMIT. COC REQUIRED NOTES SHEET KEYED NOTES LEVEL 1 T.O.CONCRETE 0" A B D T.O. Parapet LR 16' - 0" T.O. Opening 13' - 0" Upper Roof Bearing 18' - 0" T.O. Parapet HR 21' - 0" 1 A5.1E C Low Roof Bearing 10' - 0" A A B A C B A D C B T.O. Window 9' - 0" 9 10 9 1 8 A 1- 3' - 0" 6' - 0" 4' - 0" 1' - 6 1/4" 6' - 0" 1' - 6" 4' - 8 1/2" T* T* T* T* T* T* T* T* T* T* T* T* T* T* 7 LEVEL 1 T.O.CONCRETE 0" 1 2 4 5 2.1 3.1 T.O. Parapet LR 16' - 0" T.O. Opening 13' - 0" Upper Roof Bearing 18' - 0" T.O. Parapet HR 21' - 0" 2 A5.1E Low Roof Bearing 10' - 0" 3 A5.1E C A A A C A T.O. Window 9' - 0" 15 15 15 E 4- 9 9 A A 4' - 0" 3' - 0" 6' - 0" 4' - 0" T* T* T* 11 7 7 LEVEL 1 T.O.CONCRETE 0" A B D T.O. Parapet LR 16' - 0" T.O. Opening 13' - 0" Upper Roof Bearing 18' - 0" T.O. Parapet HR 21' - 0" 1 A5.1E C Low Roof Bearing 10' - 0" A A C D C A A B C T.O. Window 9' - 0" A 2- 15 9 9 9 A 7' - 0" 2' - 0" 4' - 0" 6' - 0" 3' - 0" 9' - 0" EQ EQ EQ 1' - 6" 6' - 0" 1' - 6" 4' - 8 1/2" 4' - 10 3/4" EQ EQ EQ EQ T* T* T* T* T* T* T* T* T* T* T* T* F 7 7 LEVEL 1 T.O.CONCRETE 0" 1 2 3 4 5 T.O. Parapet LR 16' - 0" Upper Roof Bearing 18' - 0" T.O. Parapet HR 21' - 0" 2 A5.1E Low Roof Bearing 10' - 0" 3 A5.1E C A A B A D A B C C T.O. Window 9' - 0" xB 3- 6' - 0" 7' - 0" 15 15 9 9 9 15 15 15 15 10 B 11 11 6' - 0" 3' - 0" 3' - 0" 11 R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 EXTERIOR ELEVATIONS TYPE A3.9 2020-07-28 1 FIRE DEPARTMENT CONNECTION F.D.C. 7 SHADE CANOPY SLOPE AWAY FROM BUILDING (MIN. 1/4" / 12") 8 BUILDING ADDRESS SEE ARCHITECTURAL SITE PLAN 9 THICKEND RIGID INSULATION ADDITIONAL 1-1/2" WITH HORIZONTAIL V REVEAL TYP 10 PRE-FINISHED METAL PARAPET CAP TYPICAL 11 STUCCO CONTROL JOINT SEE 5/A7.1 15 OVERFLOW SCUPPER. MATCH FINISH TO METAL PARAPET CAP 3/16" = 1'-0" 1 Front Elevation 3/16" = 1'-0" 2 Left Side Elevation 3/16" = 1'-0" 3 Rear Elevation (Pool Side) 3/16" = 1'-0" 4 Right Side Elevation FINISH SCHEDULE EXTERIOR MARK MATERIAL MANUF. DESCRIPTION IMAGE A STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - WINTER MORN DET617 - SAND FINISH B METAL TRIM / FASICA TBD METAL WOOD BRONZE - SMOOTH C STUCCO FINISH SYSTEM QUIKRETE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 - SAND FINISH D TILE CLADDING MARAZZI CHATEAU RESERVE - SHADOW MOUNTAIN CR42 - 6" x 48" E DOORS, AND WINDOWS DE DUNN EDWARDS - CHARCOAL SMUDGE DE6370 F GLAZING TBD CLEAR LOW-E Elux at McQueen 1855 S McQueen Rd Chandler, AZ 85286 G ELUX AT MCQUEEN 41 ELUX AT MCQUEEN 42 ELEVATIONS & FLOOR PLANS A3.1 2 A3.1 A3.1 A3.1 1 4 3 27' - 0" 2' - 0" 6' - 6" 3' - 0 1/2" 2' - 4" 1' - 6" KITCHEN 102 BEDROOM 104 LIVING ROOM 103 ENTRY 101 BATH 105 CLOSET 106 UTILITY 107 1' - 8" 2' - 4 1/2" 6' - 0 1/2" W/D WH 10" D-4 A-1 B-2 E-6 8' - 10" 4' - 6" 6' - 3 3/4" 2' - 4" xC 03- 2' - 10" 6' - 8" xD 05- 5' - 0" 6' - 8" xC 04- 2' - 10" 6' - 8" xB 02- 3' - 0" 8' - 0" xE 06- 6' - 0" 6' - 8" A B E E E E A E F A A 3' - 11" 4' - 4" 1 A5.1 A E 8' - 2" CLR 3' - 6" 3' - 6" 3' - 4" 5' - 2 3/8" 2 A5.1 WH xA 01- 3' - 0" 8' - 0" DW R/O HOOD REF PANTRY MICRO 17 E-ESCAPE E-5 1 2X6 2X6 4 PANEL 1' - 6" 4 4' - 8" 21' - 6" 10" 11' - 6" 6' - 11" PRIVATE BACKYARD FENCE LINE 5' - 0" SHEET KEYED NOTES WALL NOTES: 1 USE 5/8" TYPE X GYPSUM BOARD @ INTERIOR SIDE OF STORAGE AND MECHANICAL ROOMS 2 USE 5/8" MOISTURE RESISTANT GYPSUM BOARD IN ALL DAMP AREAS 3 USE 1/2" CEMENT BOARD UNDER CERAMIC TILE AND ALL INTERIOR STONE/BRICK VENEERS 4 PROVIDE FULL DEPTH INSULATION IN EXTERIOR WALL CAVITIES 5 PROVIDE FULL DEPTH THERMAL INSULATION IN FURRING @ EXTERIOR WALLS. USE RIGID FOAM IN CAVITIES LESS THAN 3 1/2" DEEP 6 OWNER OPTION PROVIDE FULL DEPTH SOUND ATTENUATION BATTS IN ALL INTERIOR PARTITIONS 7 ALL WOOD FRAMED WALLS SHALL HAVE A TREATED SOLE PLATE IF ON CONCRETE EXTERIOR WALLS FURRING 2 X 4 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR PARTITIONS INTERIOR INTERIOR EXTERIOR INTERIOR WALL TYPE ASSEMBLIES A E F B C 3" T&G RIGID INSULATION 2 X 4 WOOD FRAMING @ 16" O.C. "STUCCO" FINISH SYSTEM SEE STRUCTURAL 3" T&G RIGID INSULATION "STUCCO" FINISH SYSTEM SEE STRUCTURAL 1/2" GYP. BD. INTERIOR OWNER OPTION 3 1/2" ACUSTIC BATTS EXTERIOR INTERIOR 1-1/2" T&G RIGID INSULATION 2 X 4 UNO WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM SEE STRUCTURAL 1" T&G RIGID INSULATION 2 X 4 WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM NO PAINT SEE STRUCTURAL WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER THINSET PORCELAIN TILE R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-10-22 FLOOR PLAN UNIT TYPE A A2.1 2020-07-28 1/4" = 1'-0" 1 Floor Plan 1. SEE ID DRAWING SHEETS FOR FINISH PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, FINISHES, FIXTURES, AND ADDITON INFORMATION AS NOTED. 2. SEE SHEET A8.1 FOR DOOR AND WINDOW TYPE, SIZE, AND ADDITIONAL INFORMATION 3. METER - ELECTRICAL METER (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 4. PANEL - ELECTRICAL DISTRIBUTION PANEL (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 5. RTU - ROOF TOP HVAC UNIT CURB MOUNTED SCREENED BY PARAPET OR ATTACHED PRE-MANUFACTURED SCREEN, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 6. WH - ELECTRIC WATER HEATER, SEE ID, PLUMBING AND ELECTRICAL SHEETS 7. REF - REFRIGERATOR, SEE ID SHEETS 8. R/O HOOD - LISTED AND APPROVED RANGE TOP/OVEN AND HOOD EXHAUST VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL AND ELECTRICAL SHEETS 9. MICRO - MICROWAVE, SEE ID SHEETS 10. DW - DISHWASHER, SEE ID SHEETS 11. UC REF - REFRIGERATOR UNDERCOUNTER, SEE ID SHEETS 12. W/D - WASHER / DRYER ELECTRIC STACKED, VENT DRYER DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 13. W - WASHER SEE ID, PLUMBING AND ELECTRICAL SHEETS 14. D - DRYER ELECTRIC, VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 15. KITCHEN SINK TO BE UNDERMOUNT DISPOSAL AIR SWITCH ACTIVATED, SEE ID AND PLUMBING DRAWINGS 16. COUNTERTOPS TO BE SOLID SURFACE OR SIMILAR NON-ABSORBENT MATERIAL, SEE ID SHEETS 17. UPPER CABINET(S) LOCATIONS, SEE ID SHEETS 18. BASE CABINET(S) LOCATIONS, SEE ID SHEETS 19. CLOSET SHELF, ROD AND OR BUILT-IN SHELVING, SEE ID, SHEETS 20. RECESSED MEDICINE CABINET LOCATIONS, SEE ID, SHEETS 21. MIRROR LOCATIONS, SEE ID, SHEETS 22. BATHTUB WITH SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SEE ID, AND PLUMBING SHEETS 23. SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SLIDING GLASS BYPASS SHOWER DOOR WITH TEMPERED GLASS, SEE ID, AND PLUMBING SHEETS 24. SMOKE DETECTORS LOCATIONS, SEE ELECTRICAL SHEETS 25. WALL MOUNTED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 26. RECESSED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 27. CEILING FAN AT EACH BEDROOM AND LIVING ROOM, PROVIDE REQUIRED BRACING, SEE ID, AND ELECTRICAL SHEETS GENRAL PLAN NOTES:_______________________________ 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 17 4" CONCRETE SLAB WITH THICKENED EDGE OVER 4" A.B.C. SLOPE 1/8" / 12" AWAY FOR BUILDING BROOM FINISH PERPENDICULAR TO SLOPE, SEE STRUCTURAL, AND CIVIL SHEETS WALL TYPES INDICATED ON THESE PLANS TO BE WALL TYPE 1A AT LOCATIONS INDICATED ON SHEETS A1.11 AND A1.12 FSD AND FIRE RATED PLAN ELUX AT MCQUEEN 43 ELEVATIONS & FLOOR PLANS A3.1 2 A3.1 A3.1 A3.1 1 4 3 26' - 2" 12' - 0 7/8" 2' - 0" 6' - 6" 3' - 0 1/2" 2' - 4" 1' - 6" KITCHEN 102 BEDROOM 104 LIVING ROOM 103 ENTRY 101 BATH 105 CLOSET 106 UTILITY 107 1' - 8" 2' - 4 1/2" 6' - 0 1/2" 27' - 5 3/8" W/D WH 7' - 0" 19' - 2" 10" D-4 F-7 A-1 B-2 E-6 7' - 6 7/8" 8' - 10" 4' - 6" 6' - 3 3/4" 2' - 4" xC 03- 2' - 10" 6' - 8" xD 05- 5' - 0" 6' - 8" xC 04- 2' - 10" 6' - 8" xA 02- 3' - 0" 8' - 0" xE 06- 6' - 0" 6' - 8" A B E E E E A A E F A A A 14' - 2 3/8" 3' - 11" 4' - 4" 1 A5.1 A E 8' - 2" CLR 3' - 6" 2' - 1" 3' - 6" 3' - 4" 5' - 2 3/8" 2 A5.1 A WH xA 01- 3' - 0" 8' - 0" DW R/O HOOD REF PANTRY MICRO 17 E-ESCAPE E-5 1 2X6 2X6 4 PANEL 1' - 6" 4 5' - 0" 11' - 6" 6' - 11" PRIVATE BACKYARD FENCE LINE SHEET KEYED NOTES WALL NOTES: 1 USE 5/8" TYPE X GYPSUM BOARD @ INTERIOR SIDE OF STORAGE AND MECHANICAL ROOMS 2 USE 5/8" MOISTURE RESISTANT GYPSUM BOARD IN ALL DAMP AREAS 3 USE 1/2" CEMENT BOARD UNDER CERAMIC TILE AND ALL INTERIOR STONE/BRICK VENEERS 4 PROVIDE FULL DEPTH INSULATION IN EXTERIOR WALL CAVITIES 5 PROVIDE FULL DEPTH THERMAL INSULATION IN FURRING @ EXTERIOR WALLS. USE RIGID FOAM IN CAVITIES LESS THAN 3 1/2" DEEP 6 OWNER OPTION PROVIDE FULL DEPTH SOUND ATTENUATION BATTS IN ALL INTERIOR PARTITIONS 7 ALL WOOD FRAMED WALLS SHALL HAVE A TREATED SOLE PLATE IF ON CONCRETE EXTERIOR WALLS FURRING 2 X 4 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR PARTITIONS INTERIOR INTERIOR EXTERIOR INTERIOR WALL TYPE ASSEMBLIES A E F B C 3" T&G RIGID INSULATION 2 X 4 WOOD FRAMING @ 16" O.C. "STUCCO" FINISH SYSTEM SEE STRUCTURAL 3" T&G RIGID INSULATION "STUCCO" FINISH SYSTEM SEE STRUCTURAL 1/2" GYP. BD. INTERIOR OWNER OPTION 3 1/2" ACUSTIC BATTS EXTERIOR INTERIOR 1-1/2" T&G RIGID INSULATION 2 X 4 UNO WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM SEE STRUCTURAL 1" T&G RIGID INSULATION 2 X 4 WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM NO PAINT SEE STRUCTURAL WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER THINSET PORCELAIN TILE R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 FLOOR PLAN UNIT TYPE A A2.1 2020-07-28 1/4" = 1'-0" 1 Floor Plan 1. SEE ID DRAWING SHEETS FOR FINISH PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, FINISHES, FIXTURES, AND ADDITON INFORMATION AS NOTED. 2. SEE SHEET A8.1 FOR DOOR AND WINDOW TYPE, SIZE, AND ADDITIONAL INFORMATION 3. METER - ELECTRICAL METER (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 4. PANEL - ELECTRICAL DISTRIBUTION PANEL (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 5. RTU - ROOF TOP HVAC UNIT CURB MOUNTED SCREENED BY PARAPET OR ATTACHED PRE-MANUFACTURED SCREEN, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 6. WH - ELECTRIC WATER HEATER, SEE ID, PLUMBING AND ELECTRICAL SHEETS 7. REF - REFRIGERATOR, SEE ID SHEETS 8. R/O HOOD - LISTED AND APPROVED RANGE TOP/OVEN AND HOOD EXHAUST VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL AND ELECTRICAL SHEETS 9. MICRO - MICROWAVE, SEE ID SHEETS 10. DW - DISHWASHER, SEE ID SHEETS 11. UC REF - REFRIGERATOR UNDERCOUNTER, SEE ID SHEETS 12. W/D - WASHER / DRYER ELECTRIC STACKED, VENT DRYER DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 13. W - WASHER SEE ID, PLUMBING AND ELECTRICAL SHEETS 14. D - DRYER ELECTRIC, VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 15. KITCHEN SINK TO BE UNDERMOUNT DISPOSAL AIR SWITCH ACTIVATED, SEE ID AND PLUMBING DRAWINGS 16. COUNTERTOPS TO BE SOLID SURFACE OR SIMILAR NON-ABSORBENT MATERIAL, SEE ID SHEETS 17. UPPER CABINET(S) LOCATIONS, SEE ID SHEETS 18. BASE CABINET(S) LOCATIONS, SEE ID SHEETS 19. CLOSET SHELF, ROD AND OR BUILT-IN SHELVING, SEE ID, SHEETS 20. RECESSED MEDICINE CABINET LOCATIONS, SEE ID, SHEETS 21. MIRROR LOCATIONS, SEE ID, SHEETS 22. BATHTUB WITH SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SEE ID, AND PLUMBING SHEETS 23. SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SLIDING GLASS BYPASS SHOWER DOOR WITH TEMPERED GLASS, SEE ID, AND PLUMBING SHEETS 24. SMOKE DETECTORS LOCATIONS, SEE ELECTRICAL SHEETS 25. WALL MOUNTED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 26. RECESSED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 27. CEILING FAN AT EACH BEDROOM AND LIVING ROOM, PROVIDE REQUIRED BRACING, SEE ID, AND ELECTRICAL SHEETS GENRAL PLAN NOTES:_______________________________ 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 17 4" CONCRETE SLAB WITH THICKENED EDGE OVER 4" A.B.C. SLOPE 1/8" / 12" AWAY FOR BUILDING BROOM FINISH PERPENDICULAR TO SLOPE, SEE STRUCTURAL, AND CIVIL SHEETS WALL TYPES INDICATED ON THESE PLANS TO BE WALL TYPE 1A AT LOCATIONS INDICATED ON SHEETS A1.11 AND A1.12 FSD AND FIRE RATED PLAN ELUX AT MCQUEEN 44 ELEVATIONS & FLOOR PLANS A3.3 2 A3.3 A3.3 1 3 KITCHEN 102 MASTER BEDROOM 104 LIVING ROOM 103 ENTRY 101 MASTER BATH 105 WALK IN CLOSET 106 UTILITY 107 PATIO 108 BEDROOM 109 BATH 110 WALK IN CLOSET 111 PORCH 112 WH W/D 7' - 3" 1/4" 5' - 3 3/4" 10' - 10" 0" 6' - 2" 2' - 1" 21' - 3" 8' - 0" 43' - 6" A E D E A B A A B A A E E E A-1 F-2 G-3 B-4 xF 02- 6' - 0" 8' - 0" xC 03- 2' - 10" 6' - 8" xC 04- 2' - 10" 6' - 8" xC 06- 2' - 10" 6' - 8" xC 07- 2' - 10" 6' - 8" xC 05- 2' - 10" 6' - 8" xD 08- 6' - 0" 6' - 8" xA 01- 3' - 0" 8' - 0" 8' - 3 1/2" 7' - 1" 36' - 6" 8' - 2" CLR 3' - 6" E 4' - 1" 7' - 9" 7' - 1" 5' - 7 1/2" 4 1/2" 12' - 0" 7' - 10" 5' - 6 1/2" 11' - 1 1/2" 12' - 0" 7' - 10" 5' - 6 1/2" 3' - 6 1/2" 4' - 7" 4' - 0" XA4.1 1 1 A5.1 2 A5.1 AL AL 6' - 8 1/2" 4 1/2" 4 1/2" 7' - 10 1/2" WH E DW R/O HOOD REF PANTRY MICRO 3' - 4" 3' - 6" 2' - 1" 17 17 E-EGRESS E-EGRESS 1 13' - 6 1/2" 2' - 2 3/4" - --- PRIVATE BACKYARD FENCE LINE 8' - 0" 16' - 2" 6' - 0" WALL NOTES: 1 USE 5/8" TYPE X GYPSUM BOARD @ INTERIOR SIDE OF STORAGE AND MECHANICAL ROOMS 2 USE 5/8" MOISTURE RESISTANT GYPSUM BOARD IN ALL DAMP AREAS 3 USE 1/2" CEMENT BOARD UNDER CERAMIC TILE AND ALL INTERIOR STONE/BRICK VENEERS 4 PROVIDE FULL DEPTH INSULATION IN EXTERIOR WALL CAVITIES 5 PROVIDE FULL DEPTH THERMAL INSULATION IN FURRING @ EXTERIOR WALLS. USE RIGID FOAM IN CAVITIES LESS THAN 3 1/2" DEEP 6 OWNER OPTION PROVIDE FULL DEPTH SOUND ATTENUATION BATTS IN ALL INTERIOR PARTITIONS 7 ALL WOOD FRAMED WALLS SHALL HAVE A TREATED SOLE PLATE IF ON CONCRETE EXTERIOR WALLS WALL TYPE ASSEMBLIES INTERIOR PARTITIONS 2 X 4 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR E OWNER OPTION 3 1/2" ACUSTIC BATTS 2 X 6 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR D OWNER OPTION 3 1/2" ACUSTIC BATTS EXTERIOR INTERIOR A B EXTERIOR INTERIOR 1-1/2" T&G RIGID INSULATION 2 X 4 UNO WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM SEE STRUCTURAL 1" T&G RIGID INSULATION 2 X 4 WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER "STUCCO" FINISH SYSTEM NO PAINT SEE STRUCTURAL THINSET PORCELAIN TILE SHEET KEYED NOTES R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-10-22 FLOOR PLAN UNIT TYPE B A2.3 2020-07-28 1/4" = 1'-0" 1 Floor Plan 1. SEE ID DRAWING SHEETS FOR FINISH PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, FINISHES, FIXTURES, AND ADDITON INFORMATION AS NOTED. 2. SEE SHEET A8.1 FOR DOOR AND WINDOW TYPE, SIZE, AND ADDITIONAL INFORMATION 3. METER - ELECTRICAL METER (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 4. PANEL - ELECTRICAL DISTRIBUTION PANEL (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 5. RTU - ROOF TOP HVAC UNIT CURB MOUNTED SCREENED BY PARAPET OR ATTACHED PRE-MANUFACTURED SCREEN, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 6. WH - ELECTRIC WATER HEATER, SEE ID, PLUMBING AND ELECTRICAL SHEETS 7. REF - REFRIGERATOR, SEE ID SHEETS 8. R/O HOOD - LISTED AND APPROVED RANGE TOP/OVEN AND HOOD EXHAUST VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL AND ELECTRICAL SHEETS 9. MICRO - MICROWAVE, SEE ID SHEETS 10. DW - DISHWASHER, SEE ID SHEETS 11. UC REF - REFRIGERATOR UNDERCOUNTER, SEE ID SHEETS 12. W/D - WASHER / DRYER ELECTRIC STACKED, VENT DRYER DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 13. W - WASHER SEE ID, PLUMBING AND ELECTRICAL SHEETS 14. D - DRYER ELECTRIC, VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 15. KITCHEN SINK TO BE UNDERMOUNT DISPOSAL AIR SWITCH ACTIVATED, SEE ID AND PLUMBING DRAWINGS 16. COUNTERTOPS TO BE SOLID SURFACE OR SIMILAR NON-ABSORBENT MATERIAL, SEE ID SHEETS 17. UPPER CABINET(S) LOCATIONS, SEE ID SHEETS 18. BASE CABINET(S) LOCATIONS, SEE ID SHEETS 19. CLOSET SHELF, ROD AND OR BUILT-IN SHELVING, SEE ID, SHEETS 20. RECESSED MEDICINE CABINET LOCATIONS, SEE ID, SHEETS 21. MIRROR LOCATIONS, SEE ID, SHEETS 22. BATHTUB WITH SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SEE ID, AND PLUMBING SHEETS 23. SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SLIDING GLASS BYPASS SHOWER DOOR WITH TEMPERED GLASS, SEE ID, AND PLUMBING SHEETS 24. SMOKE DETECTORS LOCATIONS, SEE ELECTRICAL SHEETS 25. WALL MOUNTED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 26. RECESSED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 27. CEILING FAN AT EACH BEDROOM AND LIVING ROOM, PROVIDE REQUIRED BRACING, SEE ID, AND ELECTRICAL SHEETS GENRAL PLAN NOTES:_______________________________ 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 17 4" CONCRETE SLAB WITH THICKENED EDGE OVER 4" A.B.C. SLOPE 1/8" / 12" AWAY FOR BUILDING BROOM FINISH PERPENDICULAR TO SLOPE, SEE STRUCTURAL, AND CIVIL SHEETS WALL TYPES INDICATED ON THESE PLANS TO BE WALL TYPE 1A AT LOCATIONS INDICATED ON SHEETS A1.11 AND A1.12 FSD AND FIRE RATED PLAN ELUX AT MCQUEEN 45 ELEVATIONS & FLOOR PLANS A3.3 2 A3.3 A3.3 A3.3 1 4 3 KITCHEN 102 MASTER BEDROOM 104 LIVING ROOM 103 ENTRY 101 MASTER BATH 105 WALK IN CLOSET 106 UTILITY 107 PATIO 108 BEDROOM 109 BATH 110 WALK IN CLOSET 111 PORCH 112 WH W/D 7' - 7" 7' - 3" 1/4" 5' - 3 3/4" 10' - 10" 31' - 0" 0" 6' - 2" 2' - 1" 21' - 3" 8' - 0" 43' - 6" B A E D E A B A A B A A E E E A-1 F-2 G-3 B-4 xF 02- 6' - 0" 8' - 0" xC 03- 2' - 10" 6' - 8" xC 04- 2' - 10" 6' - 8" xC 06- 2' - 10" 6' - 8" xC 07- 2' - 10" 6' - 8" xC 05- 2' - 10" 6' - 8" xD 08- 6' - 0" 6' - 8" xA 01- 3' - 0" 8' - 0" 15' - 7 1/2" 8' - 3 1/2" 7' - 1" 31' - 0" 36' - 6" 8' - 2" CLR 3' - 6" E 11' - 5" 4' - 1" 7' - 9" 7' - 1" 5' - 7 1/2" 4 1/2" 12' - 0" 7' - 10" 5' - 6 1/2" 11' - 1 1/2" 12' - 0" 7' - 10" 5' - 6 1/2" 3' - 6 1/2" 4' - 7" 4' - 0" XA4.1 1 1 A5.1 2 A5.1 AL AL 6' - 8 1/2" 4 1/2" 4 1/2" 7' - 10 1/2" WH E DW R/O HOOD REF PANTRY MICRO 3' - 4" 3' - 6" 2' - 1" 17 17 E-EGRESS E-EGRESS 1 13' - 6 1/2" 2' - 2 3/4" - --- PRIVATE BACKYARD FENCE LINE 8' - 0" 16' - 1 3/4" 6' - 0" WALL NOTES: 1 USE 5/8" TYPE X GYPSUM BOARD @ INTERIOR SIDE OF STORAGE AND MECHANICAL ROOMS 2 USE 5/8" MOISTURE RESISTANT GYPSUM BOARD IN ALL DAMP AREAS 3 USE 1/2" CEMENT BOARD UNDER CERAMIC TILE AND ALL INTERIOR STONE/BRICK VENEERS 4 PROVIDE FULL DEPTH INSULATION IN EXTERIOR WALL CAVITIES 5 PROVIDE FULL DEPTH THERMAL INSULATION IN FURRING @ EXTERIOR WALLS. USE RIGID FOAM IN CAVITIES LESS THAN 3 1/2" DEEP 6 OWNER OPTION PROVIDE FULL DEPTH SOUND ATTENUATION BATTS IN ALL INTERIOR PARTITIONS 7 ALL WOOD FRAMED WALLS SHALL HAVE A TREATED SOLE PLATE IF ON CONCRETE EXTERIOR WALLS WALL TYPE ASSEMBLIES INTERIOR PARTITIONS 2 X 4 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR E OWNER OPTION 3 1/2" ACUSTIC BATTS 2 X 6 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR D OWNER OPTION 3 1/2" ACUSTIC BATTS EXTERIOR INTERIOR A B EXTERIOR INTERIOR 1-1/2" T&G RIGID INSULATION 2 X 4 UNO WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM SEE STRUCTURAL 1" T&G RIGID INSULATION 2 X 4 WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER "STUCCO" FINISH SYSTEM NO PAINT SEE STRUCTURAL THINSET PORCELAIN TILE SHEET KEYED NOTES R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 FLOOR PLAN UNIT TYPE B A2.3 2020-07-28 1/4" = 1'-0" 1 Floor Plan 1. SEE ID DRAWING SHEETS FOR FINISH PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, FINISHES, FIXTURES, AND ADDITON INFORMATION AS NOTED. 2. SEE SHEET A8.1 FOR DOOR AND WINDOW TYPE, SIZE, AND ADDITIONAL INFORMATION 3. METER - ELECTRICAL METER (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 4. PANEL - ELECTRICAL DISTRIBUTION PANEL (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 5. RTU - ROOF TOP HVAC UNIT CURB MOUNTED SCREENED BY PARAPET OR ATTACHED PRE-MANUFACTURED SCREEN, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 6. WH - ELECTRIC WATER HEATER, SEE ID, PLUMBING AND ELECTRICAL SHEETS 7. REF - REFRIGERATOR, SEE ID SHEETS 8. R/O HOOD - LISTED AND APPROVED RANGE TOP/OVEN AND HOOD EXHAUST VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL AND ELECTRICAL SHEETS 9. MICRO - MICROWAVE, SEE ID SHEETS 10. DW - DISHWASHER, SEE ID SHEETS 11. UC REF - REFRIGERATOR UNDERCOUNTER, SEE ID SHEETS 12. W/D - WASHER / DRYER ELECTRIC STACKED, VENT DRYER DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 13. W - WASHER SEE ID, PLUMBING AND ELECTRICAL SHEETS 14. D - DRYER ELECTRIC, VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 15. KITCHEN SINK TO BE UNDERMOUNT DISPOSAL AIR SWITCH ACTIVATED, SEE ID AND PLUMBING DRAWINGS 16. COUNTERTOPS TO BE SOLID SURFACE OR SIMILAR NON-ABSORBENT MATERIAL, SEE ID SHEETS 17. UPPER CABINET(S) LOCATIONS, SEE ID SHEETS 18. BASE CABINET(S) LOCATIONS, SEE ID SHEETS 19. CLOSET SHELF, ROD AND OR BUILT-IN SHELVING, SEE ID, SHEETS 20. RECESSED MEDICINE CABINET LOCATIONS, SEE ID, SHEETS 21. MIRROR LOCATIONS, SEE ID, SHEETS 22. BATHTUB WITH SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SEE ID, AND PLUMBING SHEETS 23. SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SLIDING GLASS BYPASS SHOWER DOOR WITH TEMPERED GLASS, SEE ID, AND PLUMBING SHEETS 24. SMOKE DETECTORS LOCATIONS, SEE ELECTRICAL SHEETS 25. WALL MOUNTED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 26. RECESSED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 27. CEILING FAN AT EACH BEDROOM AND LIVING ROOM, PROVIDE REQUIRED BRACING, SEE ID, AND ELECTRICAL SHEETS GENRAL PLAN NOTES:_______________________________ 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 17 4" CONCRETE SLAB WITH THICKENED EDGE OVER 4" A.B.C. SLOPE 1/8" / 12" AWAY FOR BUILDING BROOM FINISH PERPENDICULAR TO SLOPE, SEE STRUCTURAL, AND CIVIL SHEETS WALL TYPES INDICATED ON THESE PLANS TO BE WALL TYPE 1A AT LOCATIONS INDICATED ON SHEETS A1.11 AND A1.12 FSD AND FIRE RATED PLAN ELUX AT MCQUEEN 46 ELEVATIONS & FLOOR PLANS UP DN 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 A3.5 2 A3.5 A3.5 1 4 KITCHEN 102 MASTER BEDROOM 104 ENTRY 101 M. BATH 105 WALK IN CLOSET 106 UTILITY 107 PATIO 110 xA 01- 3' - 0" 8' - 0" xC 03- 2' - 10" 6' - 8" xC 02- 2' - 10" 6' - 8" STORAGE 108 LIVING ROOM & DINING ROOM 103 1 A5.1 2 A5.1 6' - 5 1/2" 3' - 2 1/2" 12' - 6" E B D D A B E E E 18' - 8" 9' - 10" 28' - 6" 13' - 7 1/2" 12' - 10 1/2" 26' - 6" xC 15- 2' - 8" 6' - 8" xD 20- 5' - 0" 6' - 8" x 05-F 5F- 6' - 0" 8' - 0" 8' - 2" 3' - 6" 3' - 4" CLR 3' - 6" 2' - 1" A-1 C-3 D-4 F-2 13' - 8 3/8" 1' - 11 5/8" 5' - 9" 5' - 9" AL A A 3' - 9" 7" 2 3/4" 6' - 7 5/8" 2' - 11 1/8" 5' - 7 1/2" 0" 4 1/2" 3 3/4" 13' - 2 3/4" 2' - 2 3/4" W WH D DW R/O HOOD REF PANTRY MICRO 17 17 4 4 4 9R@7 11/16" 6' - 8" CLEAR 3' - 1 1/2" 19 21 E-ESCAPE 4 1 D PRIVATE BACKYARD FENCE LINE 8' - 0" 6' - 0" 15' - 5 1/2" A3.5 2 A3.5 A3.5 A3.5 1 4 3 BEDROOM 2 201 BATH 2 205 WALK IN CLOSET 202 BEDROOM 3 203 HALLWAY 200 CLOSET 204 DUCT 1 A5.1 2 A5.1 F F E E A-5 D-7 D-8 D-4 D-6 15' - 8" 5' - 9" 5' - 9" 6' - 0" 7' - 10" 3' - 3" 4' - 11" 6' - 7 1/2" 6' - 6 1/2" 11' - 1" E A 3' - 8 1/2" xC 09- 2' - 6" 6' - 8" E 4 BELOW 4 4 BELOW BELOW LANDING 3' - 2" 8R@7 11/16" 5' - 10" CLEAR 6' - 7 1/2" 20 20 19 E-ESCAPE E-ESCAPE xC 35- 2' - 10" 6' - 8" E xE 36- 6' - 0" 6' - 8" xC 37- 2' - 10" 6' - 8" 4 BELOW E xC 38- 2' - 6" 6' - 8" D EQ EQ 12' - 8 1/2" E WALL NOTES: 1 USE 5/8" TYPE X GYPSUM BOARD @ INTERIOR SIDE OF STORAGE AND MECHANICAL ROOMS 2 USE 5/8" MOISTURE RESISTANT GYPSUM BOARD IN ALL DAMP AREAS 3 USE 1/2" CEMENT BOARD UNDER CERAMIC TILE AND ALL INTERIOR STONE/BRICK VENEERS 4 PROVIDE FULL DEPTH INSULATION IN EXTERIOR WALL CAVITIES 5 PROVIDE FULL DEPTH THERMAL INSULATION IN FURRING @ EXTERIOR WALLS. USE RIGID FOAM IN CAVITIES LESS THAN 3 1/2" DEEP 6 OWNER OPTION PROVIDE FULL DEPTH SOUND ATTENUATION BATTS IN ALL INTERIOR PARTITIONS 7 ALL WOOD FRAMED WALLS SHALL HAVE A TREATED SOLE PLATE IF ON CONCRETE EXTERIOR WALLS FURRING INTERIOR PARTITIONS WALL TYPE ASSEMBLIES F 1/2" GYPSUM BOARD INTERIOR 2 X 4 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR E OWNER OPTION 3 1/2" ACUSTIC BATTS 2 X 6 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR D OWNER OPTION 3 1/2" ACUSTIC BATTS EXTERIOR INTERIOR A B EXTERIOR INTERIOR 1-1/2" T&G RIGID INSULATION R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM SEE STRUCTURAL 1" T&G RIGID INSULATION 2 X 4 WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM NO PAINT SEE STRUCTURAL WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER 2 X 4 UNO WOOD FRAMING @ 16" O.C. THINSET PORCELAIN TILE SHEET KEYED NOTES R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-10-23 FLOOR PLANS UNIT TYPE C A2.5 2020-07-28 1/4" = 1'-0" 1 Level 1 Floor Plan 1/4" = 1'-0" 2 Level 2 Floor Plan 1. SEE ID DRAWING SHEETS FOR FINISH PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, FINISHES, FIXTURES, AND ADDITON INFORMATION AS NOTED. 2. SEE SHEET A8.1 FOR DOOR AND WINDOW TYPE, SIZE, AND ADDITIONAL INFORMATION 3. METER - ELECTRICAL METER (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 4. PANEL - ELECTRICAL DISTRIBUTION PANEL (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 5. RTU - ROOF TOP HVAC UNIT CURB MOUNTED SCREENED BY PARAPET OR ATTACHED PRE-MANUFACTURED SCREEN, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 6. WH - ELECTRIC WATER HEATER, SEE ID, PLUMBING AND ELECTRICAL SHEETS 7. REF - REFRIGERATOR, SEE ID SHEETS 8. R/O HOOD - LISTED AND APPROVED RANGE TOP/OVEN AND HOOD EXHAUST VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL AND ELECTRICAL SHEETS 9. MICRO - MICROWAVE, SEE ID SHEETS 10. DW - DISHWASHER, SEE ID SHEETS 11. UC REF - REFRIGERATOR UNDERCOUNTER, SEE ID SHEETS 12. W/D - WASHER / DRYER ELECTRIC STACKED, VENT DRYER DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 13. W - WASHER SEE ID, PLUMBING AND ELECTRICAL SHEETS 14. D - DRYER ELECTRIC, VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 15. KITCHEN SINK TO BE UNDERMOUNT DISPOSAL AIR SWITCH ACTIVATED, SEE ID AND PLUMBING DRAWINGS 16. COUNTERTOPS TO BE SOLID SURFACE OR SIMILAR NON-ABSORBENT MATERIAL, SEE ID SHEETS 17. UPPER CABINET(S) LOCATIONS, SEE ID SHEETS 18. BASE CABINET(S) LOCATIONS, SEE ID SHEETS 19. CLOSET SHELF, ROD AND OR BUILT-IN SHELVING, SEE ID, SHEETS 20. RECESSED MEDICINE CABINET LOCATIONS, SEE ID, SHEETS 21. MIRROR LOCATIONS, SEE ID, SHEETS 22. BATHTUB WITH SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SEE ID, AND PLUMBING SHEETS 23. SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SLIDING GLASS BYPASS SHOWER DOOR WITH TEMPERED GLASS, SEE ID, AND PLUMBING SHEETS 24. SMOKE DETECTORS LOCATIONS, SEE ELECTRICAL SHEETS 25. WALL MOUNTED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 26. RECESSED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 27. CEILING FAN AT EACH BEDROOM AND LIVING ROOM, PROVIDE REQUIRED BRACING, SEE ID, AND ELECTRICAL SHEETS GENRAL PLAN NOTES:_______________________________ 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 17 4" CONCRETE SLAB WITH THICKENED EDGE OVER 4" A.B.C. SLOPE 1/8" / 12" AWAY FOR BUILDING BROOM FINISH PERPENDICULAR TO SLOPE, SEE STRUCTURAL, AND CIVIL SHEETS 19 WOOD HANDRAIL AT 35" ABOVE NOSE OF TREAD WALL MOUNTED RETURN TO WALL AT ENDS AND NEWEL POST ON FIRST TREAD 20 PARTIAL HEIGHT WALL 36" AFF RAKE PARALLEL TO STAIR SLOPE WITH WOOD CAP 21 5/8" GYPSUM BOARD APPLIED TO UNDERSIDE OF STAIRS AND LANDING WALL TYPES INDICATED ON THESE PLANS TO BE WALL TYPE 1A AT LOCATIONS INDICATED ON SHEETS A1.11 AND A1.12 FSD AND FIRE RATED PLAN ELUX AT MCQUEEN 47 ELEVATIONS & FLOOR PLANS UP DN 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 A3.5 2 A3.5 A3.5 1 4 KITCHEN 102 MASTER BEDROOM 104 ENTRY 101 M. BATH 105 WALK IN CLOSET 106 UTILITY 107 PATIO 110 xA 01- 3' - 0" 8' - 0" xC 03- 2' - 10" 6' - 8" xC 02- 2' - 10" 6' - 8" STORAGE 108 LIVING ROOM & DINING ROOM 103 1 A5.1 2 A5.1 8' - 0" 6' - 5 1/2" 3' - 2 1/2" 12' - 6" 30' - 2" E B D D A B E E E 18' - 8" 9' - 10" 28' - 6" 13' - 7 1/2" 12' - 10 1/2" 26' - 6" xC 15- 2' - 8" 6' - 8" xD 20- 5' - 0" 6' - 8" x 05-F 5F- 6' - 0" 8' - 0" 8' - 2" 3' - 6" 3' - 4" CLR 3' - 6" 2' - 1" A-1 C-3 D-4 F-2 13' - 8 3/8" 1' - 11 5/8" 5' - 9" 5' - 9" AL A A 3' - 9" 7" 2 3/4" 6' - 7 5/8" 2' - 11 1/8" 5' - 7 1/2" 0" 4 1/2" 3 3/4" 13' - 2 3/4" 2' - 2 3/4" W WH D DW R/O HOOD REF PANTRY MICRO 17 17 4 4 4 9R@7 11/16" 6' - 8" CLEAR 3' - 1 1/2" 19 21 E-ESCAPE 4 1 D PRIVATE BACKYARD FENCE LINE 8' - 0" 6' - 0" 15' - 5 1/2" A3.5 2 A3.5 A3.5 A3.5 1 4 3 BEDROOM 2 201 BATH 2 205 WALK IN CLOSET 202 BEDROOM 3 203 HALLWAY 200 CLOSET 204 DUCT 1 A5.1 2 A5.1 F F E E B A-5 D-7 D-8 D-4 D-6 3' - 0" 15' - 8" 5' - 9" 5' - 9" 30' - 2" 6' - 0" 7' - 10" 3' - 3" 4' - 11" 5' - 3" 6' - 7 1/2" 6' - 6 1/2" 11' - 1" E A 3' - 8 1/2" xC 09- 2' - 6" 6' - 8" E 4 BELOW 4 4 BELOW BELOW LANDING 3' - 2" 8R@7 11/16" 5' - 10" CLEAR 6' - 7 1/2" 20 20 19 E-ESCAPE E-ESCAPE xC 35- 2' - 10" 6' - 8" E xE 36- 6' - 0" 6' - 8" xC 37- 2' - 10" 6' - 8" 4 BELOW E xC 38- 2' - 6" 6' - 8" D EQ EQ EQ EQ WALL NOTES: 1 USE 5/8" TYPE X GYPSUM BOARD @ INTERIOR SIDE OF STORAGE AND MECHANICAL ROOMS 2 USE 5/8" MOISTURE RESISTANT GYPSUM BOARD IN ALL DAMP AREAS 3 USE 1/2" CEMENT BOARD UNDER CERAMIC TILE AND ALL INTERIOR STONE/BRICK VENEERS 4 PROVIDE FULL DEPTH INSULATION IN EXTERIOR WALL CAVITIES 5 PROVIDE FULL DEPTH THERMAL INSULATION IN FURRING @ EXTERIOR WALLS. USE RIGID FOAM IN CAVITIES LESS THAN 3 1/2" DEEP 6 OWNER OPTION PROVIDE FULL DEPTH SOUND ATTENUATION BATTS IN ALL INTERIOR PARTITIONS 7 ALL WOOD FRAMED WALLS SHALL HAVE A TREATED SOLE PLATE IF ON CONCRETE EXTERIOR WALLS FURRING INTERIOR PARTITIONS WALL TYPE ASSEMBLIES F 1/2" GYPSUM BOARD INTERIOR 2 X 4 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR E OWNER OPTION 3 1/2" ACUSTIC BATTS 2 X 6 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR D OWNER OPTION 3 1/2" ACUSTIC BATTS EXTERIOR INTERIOR A B EXTERIOR INTERIOR 1-1/2" T&G RIGID INSULATION R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM SEE STRUCTURAL 1" T&G RIGID INSULATION 2 X 4 WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD "STUCCO" FINISH SYSTEM NO PAINT SEE STRUCTURAL WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER 2 X 4 UNO WOOD FRAMING @ 16" O.C. THINSET PORCELAIN TILE SHEET KEYED NOTES R T E O N g LANCE D. 35529 BAKER S I ZO R A i a e t D C . . A n e , S . U . d . . . . . A . . . . . . . . E E R F I R T G S I E T C E AR C T I T A N E H C I D This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS EXP. 12/31/2021 PDP BLB LDB 4014 2020-07-28 FLOOR PLANS UNIT TYPE C A2.5 2020-07-28 1/4" = 1'-0" 1 Level 1 Floor Plan 1/4" = 1'-0" 2 Level 2 Floor Plan 1. SEE ID DRAWING SHEETS FOR FINISH PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, FINISHES, FIXTURES, AND ADDITON INFORMATION AS NOTED. 2. SEE SHEET A8.1 FOR DOOR AND WINDOW TYPE, SIZE, AND ADDITIONAL INFORMATION 3. METER - ELECTRICAL METER (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 4. PANEL - ELECTRICAL DISTRIBUTION PANEL (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 5. RTU - ROOF TOP HVAC UNIT CURB MOUNTED SCREENED BY PARAPET OR ATTACHED PRE-MANUFACTURED SCREEN, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 6. WH - ELECTRIC WATER HEATER, SEE ID, PLUMBING AND ELECTRICAL SHEETS 7. REF - REFRIGERATOR, SEE ID SHEETS 8. R/O HOOD - LISTED AND APPROVED RANGE TOP/OVEN AND HOOD EXHAUST VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL AND ELECTRICAL SHEETS 9. MICRO - MICROWAVE, SEE ID SHEETS 10. DW - DISHWASHER, SEE ID SHEETS 11. UC REF - REFRIGERATOR UNDERCOUNTER, SEE ID SHEETS 12. W/D - WASHER / DRYER ELECTRIC STACKED, VENT DRYER DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 13. W - WASHER SEE ID, PLUMBING AND ELECTRICAL SHEETS 14. D - DRYER ELECTRIC, VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 15. KITCHEN SINK TO BE UNDERMOUNT DISPOSAL AIR SWITCH ACTIVATED, SEE ID AND PLUMBING DRAWINGS 16. COUNTERTOPS TO BE SOLID SURFACE OR SIMILAR NON-ABSORBENT MATERIAL, SEE ID SHEETS 17. UPPER CABINET(S) LOCATIONS, SEE ID SHEETS 18. BASE CABINET(S) LOCATIONS, SEE ID SHEETS 19. CLOSET SHELF, ROD AND OR BUILT-IN SHELVING, SEE ID, SHEETS 20. RECESSED MEDICINE CABINET LOCATIONS, SEE ID, SHEETS 21. MIRROR LOCATIONS, SEE ID, SHEETS 22. BATHTUB WITH SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SEE ID, AND PLUMBING SHEETS 23. SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SLIDING GLASS BYPASS SHOWER DOOR WITH TEMPERED GLASS, SEE ID, AND PLUMBING SHEETS 24. SMOKE DETECTORS LOCATIONS, SEE ELECTRICAL SHEETS 25. WALL MOUNTED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 26. RECESSED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 27. CEILING FAN AT EACH BEDROOM AND LIVING ROOM, PROVIDE REQUIRED BRACING, SEE ID, AND ELECTRICAL SHEETS GENRAL PLAN NOTES:_______________________________ 1 FIRE SPRINKLER EQUIPMENT ACCESS PANEL PAINT TO MATCH WALL, AT BUILDINGS DELINEATED TO BE SPRINKLERED ON SHEETS A1.11 AND A1.12. SEE FIRE SPRINKLERS / FIRE PROTECTION DEFERRED SUBMITTAL 4 WOOD POST FOR SHADE CANOPY WITH 1X TRIM AT TOP AND BASE CONNECTIONS, SEE STRUCTURAL SHEETS 17 4" CONCRETE SLAB WITH THICKENED EDGE OVER 4" A.B.C. SLOPE 1/8" / 12" AWAY FOR BUILDING BROOM FINISH PERPENDICULAR TO SLOPE, SEE STRUCTURAL, AND CIVIL SHEETS 19 WOOD HANDRAIL AT 35" ABOVE NOSE OF TREAD WALL MOUNTED RETURN TO WALL AT ENDS AND NEWEL POST ON FIRST TREAD 20 PARTIAL HEIGHT WALL 36" AFF RAKE PARALLEL TO STAIR SLOPE WITH WOOD CAP 21 5/8" GYPSUM BOARD APPLIED TO UNDERSIDE OF STAIRS AND LANDING WALL TYPES INDICATED ON THESE PLANS TO BE WALL TYPE 1A AT LOCATIONS INDICATED ON SHEETS A1.11 AND A1.12 FSD AND FIRE RATED PLAN ELUX AT MCQUEEN 48 ELEVATIONS & FLOOR PLANS DN DN A3.8 2 A3.7 A3.7 2 1 UTILITY 112 ENTRY 101 KITCHEN 102 LIVING ROOM 103 MASTER BEDROOM 104 MASTER BATHROOM 105 WALK IN CLOSET 106 A3.8 1 BALCONY 108 ENTRY 109 MASTER BEDROOM 113 MASTER BATHROOM 114 LIVING ROOM 111 WALK IN CLOSET 115 BALCONY 126 BEDROOM #2 118 WALK IN CLOSET 117 BATH #2 116 UTILITY 107 A3.8 2 A3.7 A3.7 2 1 UNIT TYPE E GARAGE PRIVATE GARAGE PRIVATE GARAGE PRIVATE GARAGE PRIVATE GARAGE PRIVATE GARAGE UNIT TYPE D GARAGE A3.8 1 FIRE RISER 1/8" / 12" 1/8" / 12" 1/8" / 12" 1/8" / 12" 1/8" / 12" 1/8" / 12" 1/8" / 12" SHEET KEYED NOTES NOTES: 1 USE 5/8" TYPE X GYPSUM BOARD @ INTERIOR SIDE OF STORAGE AND MECHANICAL ROOMS 2 USE 5/8" MOISTURE RESISTANT GYPSUM BOARD IN ALL DAMP AREAS 3 USE 1/2" CEMENT BOARD UNDER CERAMIC TILE AND ALL INTERIOR STONE/BRICK VENEERS 4 PROVIDE FULL DEPTH INSULATION IN EXTERIOR WALL CAVITIES 5 PROVIDE FULL DEPTH THERMAL INSULATION IN FURRING @ EXTERIOR WALLS. USE RIGID FOAM IN CAVITIES LESS THAN 3 1/2" DEEP 6 PROVIDE FULL DEPTH SOUND ATTENUATION BATTS IN ALL INTERIOR PARTITIONS 7 ALL WOOD FRAMED WALLS SHALL HAVE A TREATED SOLE PLATE 2 x 6 FRAMING @ 16" O.C. SEE PLAN FOR DIM 1/2" GYPSUM BOARD INTERIOR FURRING F 2 x 4 FRAMING @ 16" O.C. SEE PLAN FOR DIM 1/2" GYPSUM BOARD INTERIOR G 2 x 4 FRAMING @ 16" O.C. 5/8" TYPE 'X' GYPSUM BOARD 5/8" TYPE 'X' GYPSUM BOARD INTERIOR INTERIOR E1 2 x 4 FRAMING @ 16" O.C. SEE PLAN FOR DIM 1/2" PLYWOOD SHEATHING INTERIOR H 1/2" GYPSUM BOARD 1/2" PLYWOOD SHEATHING 1/2" GYPSUM BOARD 2 x 4 FRAMING @ 16" O.C. SEE PLAN FOR DIM 1/2" PLYWOOD SHEATHING GARAGE H1 5/8" TYPE 'X' GYPSUM BOARD 1/2" PLYWOOD SHEATHING 5/8" TYPE 'X' GYPSUM BOARD INTERIOR GARAGE 2 x 4 FRAMING @ 16" O.C. SEE PLAN FOR DIM 1/2" PLYWOOD SHEATHING GARAGE H2 5/8" GYPSUM BOARD 1/2" PLYWOOD SHEATHING 1/2" GYPSUM BOARD INTERIOR SHEAR WALLS 2 x 4 FRAMING @ 16" O.C. (STAGGERED) (2) LAYERS OF 5/8" TYPE 'X' GYPSUM BOARD INTERIOR INTERIOR J (2) LAYERS OF 5/8" TYPE 'X' GYPSUM BOARD 1" SEPARATION WALLS UL - U376 STC 55 3-1/2" MINERAL FIBER INSULATION 3 1/2" ACUSTIC BATTS UL - U305 1-HOUR UL - U356 1-HOUR EXTERIOR WALLS INTERIOR PARTITIONS WALL TYPE ASSEMBLIES 2 X 4 WOOD FRAMING @ 16" O.C. 2 X 6 WOOD FRAMING @ 16" O.C. @ A1 and A2 R-13 BATT INSULATION 1/2" GYPSUM BOARD 5/8" GYPSUM BOARD @ A1 and A2 EXTERIOR INTERIOR A B 2 X 4 WOOD FRAMING @ 16" O.C. R-13 BATT INSULATION 1/2" GYPSUM BOARD EXTERIOR INTERIOR 2 X 4 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR E OWNER OPTION 3 1/2" ACUSTIC BATTS 2 X 6 FRAMING @ 16" O.C. 1/2" GYPSUM BOARD 1/2" GYPSUM BOARD INTERIOR INTERIOR D OWNER OPTION 3 1/2" ACUSTIC BATTS PLYWOOD SHEATHING @ A1 A1 A2 1-1/2" T&G RIGID INSULATION "STUCCO" FINISH SYSTEM SEE STRUCTURAL WEATHER RESISTANT BARRIER 1" T&G RIGID INSULATION "STUCCO" FINISH SYSTEM NO PAINT SEE STRUCTURAL CERAMIC TILE WEATHER RESISTANT BARRIER This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS PDP BLB LDB 4014 2019-11-11 FLOOR PLANS UNIT TYPE D A2.7 1/4" = 1'-0" 2 UNIT D and E Level 2 Floor Plan 1/4" = 1'-0" 1 UNIT D and E Level 1 Floor Plan 1. SEE ID DRAWING SHEETS FOR FINISH PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, FINISHES, FIXTURES, AND ADDITON INFORMATION AS NOTED. 2. SEE SHEET A8.1 FOR DOOR AND WINDOW TYPE, SIZE, AND ADDITIONAL INFORMATION 3. METER - ELECTRICAL METER (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 4. PANEL - ELECTRICAL DISTRIBUTION PANEL (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 5. RTU - ROOF TOP HVAC UNIT CURB MOUNTED SCREENED BY PARAPET OR ATTACHED PRE-MANUFACTURED SCREEN, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 6. WH - ELECTRIC WATER HEATER, SEE ID, PLUMBING AND ELECTRICAL SHEETS 7. REF - REFRIGERATOR, SEE ID SHEETS GENRAL PLAN NOTES:____________________________________________________________________________________________________________________________________________ 8. R/O HOOD - LISTED AND APPROVED RANGE TOP/OVEN AND HOOD EXHAUST VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL AND ELECTRICAL SHEETS 9. MICRO - MICROWAVE, SEE ID SHEETS 10. DW - DISHWASHER, SEE ID SHEETS 11. UC REF - REFRIGERATOR UNDERCOUNTER, SEE ID SHEETS 12. W/D - WASHER / DRYER ELECTRIC STACKED, VENT DRYER DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 13. W - WASHER SEE ID, PLUMBING AND ELECTRICAL SHEETS 14. D - DRYER ELECTRIC, VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 15. KITCHEN SINK TO BE UNDERMOUNT DISPOSAL AIR SWITCH ACTIVATED, SEE ID AND PLUMBING DRAWINGS 16. COUNTERTOPS TO BE SOLID SURFACE OR SIMILAR NON-ABSORBENT MATERIAL, SEE ID SHEETS 17. UPPER CABINET(S) LOCATIONS, SEE ID SHEETS 18. BASE CABINET(S) LOCATIONS, SEE ID SHEETS 19. CLOSET SHELF, ROD AND OR BUILT-IN SHELVING, SEE ID, SHEETS 20. RECESSED MEDICINE CABINET LOCATIONS, SEE ID, SHEETS 21. MIRROR LOCATIONS, SEE ID, SHEETS 22. BATHTUB WITH SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SEE ID, AND PLUMBING SHEETS 23. SHOWER, PROVIDE NONABSORBENT WALL SURFACE TO 6'-0" A.F.F. MINIMUM REQUIREMENT, SLIDING GLASS BYPASS SHOWER DOOR WITH TEMPERED GLASS, SEE ID, AND PLUMBING SHEETS 24. SMOKE DETECTORS LOCATIONS, SEE ELECTRICAL SHEETS 25. WALL MOUNTED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 26. RECESSED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 27. CEILING FAN AT EACH BEDROOM AND LIVING ROOM, PROVIDE REQUIRED BRACING, SEE ID, AND ELECTRICAL SHEETS ELUX AT MCQUEEN 49 ELEVATIONS & FLOOR PLANS FD FD A3.9 2 A3.9 A3.9 A3.9 1 4 3 A A B B D D 1 1 2 2 3 4 4 5 5 2.1 3.1 842 SF LEASING / LOUNGE 100 OL=17 504 SF LOUNGE 101 OL=14 389 SF KITCHEN 102 OL=17 722 SF FITNESS 103 OL=15 148 SF KITCHENETTE 104 OL=6 112 SF OFFICE 105 OL=1 112 SF OFFICE 106 OL=1 52 SF RISER / MECHANICAL 107 19 SF SERVER 108 127 SF HALLWAY 109 116 SF WOMEN 110 116 SF MEN 111 89 SF JANITOR / STORAGE 112 OL=1 C C GAS METER NOTES: 1 USE 5/8" TYPE X GYPSUM BOARD @ INTERIOR SIDE OF STORAGE AND MECHANICAL ROOMS 2 USE 5/8" MOISTURE RESISTANT GYPSUM BOARD IN ALL DAMP AREAS 3 USE 1/2" CEMENT BOARD UNDER CERAMIC TILE AND ALL INTERIOR STONE/BRICK VENEERS 4 PROVIDE FULL DEPTH INSULATION IN EXTERIOR WALL CAVITIES 5 PROVIDE FULL DEPTH THERMAL INSULATION IN FURRING @ EXTERIOR WALLS. USE RIGID FOAM IN CAVITIES LESS THAN 3 1/2" DEEP 6 PROVIDE FULL DEPTH SOUND ATTENUATION BATTS IN ALL INTERIOR PARTITIONS 7 ALL WOOD FRAMED WALLS SHALL HAVE A TREATED SOLE PLATE 2 x 6 FRAMING @ 16" O.C. SEE PLAN FOR DIM 5/8" GYPSUM BOARD EXTERIOR WALLS INTERIOR FURRING 2 x 6 FRAMING @ 16" O.C. 5/8" GYPSUM BOARD 5/8" GYPSUM BOARD 2 x 4 FRAMING @ 16" O.C. 5/8" GYPSUM BOARD 5/8" GYPSUM BOARD INTERIOR PARTITIONS INTERIOR INTERIOR INTERIOR INTERIOR 1-1/2" RIGID INSULATION TYP UNO PLYWOOD SHEATHING 2 x 6 WOOD FRAMING @ 16" O.C. R-21 BATT INSULATION 5/8" GYPSUM BOARD NO INTERIOR GYSPUM BOARD @ A1 EXTERIOR INTERIOR WALL TYPE LEGEND A D E F STUCCO FINISH SYSTEM "STUCCO" FINISH SYSTEM NO PAINT SEE STRUCTURAL PLYWOOD SHEATHING 2 x 6 WOOD FRAMING @ 16" O.C. R-21 BATT INSULATION 5/8" GYPSUM BOARD EXTERIOR INTERIOR B THINSET PORCELAIN TILE 2 x 4 FRAMING @ 16" O.C. SEE PLAN FOR DIM 5/8" GYPSUM BOARD INTERIOR G C 3" RIGID INSULATION PLYWOOD SHEATHING 2 x 6 WOOD FRAMING @ 16" O.C. STUCCO FINISH SYSTEM 3" RIGID INSULATION PLY WOOD SHEATHING STUCCO FINISH SYSTEM SEE PLAN 3 1/2" ACUSTIC BATTS 3 1/2" ACUSTIC BATTS WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER WEATHER RESISTANT BARRIER OCCUPANT LOAD: AREA (SF) LOAD FACTOR OCCUPANT LOAD BUSINESS RM 105 - OFFICE 112 150 GROSS 0.75 RM 106 - OFFICE 112 150 GROSS 0.75 ASSEMBLY (UNCONCENTRATED) RM 100 - LEASING/LOUNGE 250 15 NET 16.7 RM 101 - LOUNGE 205 15 NET 13.7 RM 102 - KITCHEN 250 15 NET 16.7 RM 104 - KITCHENETTE 85 15 NET 5.6 FITNESS RM 103 - FITNESS 722 50 GROSS 14.4 ACCESSORY AREA RM 112 - JANITOR/STORAGE 89 300 GROSS 0.30 TOTAL 68.9 SHEET KEYED NOTES This drawing is the property of Synectic Design Incorporated, 688 W. 1st Street, Suite #3, Tempe Az, 85281, 480.948.9766. This drawing is limited to the original use for which it was prepared. Changes, reproductions, or assigning to any third party of this drawing for any other use is not permited without written consent of Synectic Design Incorporated. C 2015 S Y N E C T I C D E S I G N 1111 West University Drive, Suite 104, Tempe, AZ 85281 t:480.948.9766 f:480.948.9211 Phase: Drawn By: Reviewd By: SDI Project No: Date: Sheet: REVISIONS PDP BLB LDB 4014 2019-11-11 FLOOR PLAN TYPE G A2.8 1/4" = 1'-0" 1 Clubhouse and Leasing Office Floor plan north 1. SEE ID DRAWING SHEETS FOR FINISH PLAN, REFLECTED CEILING PLAN, INTERIOR ELEVATIONS, FINISHES, FIXTURES, BUILT-IN, AND ADDITON INFORMATION AS NOTED. 2. SEE SHEET A8.1 FOR DOOR AND WINDOW TYPE, SIZE, AND ADDITIONAL INFORMATION 3. METER - ELECTRICAL METER (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 4. PANEL - ELECTRICAL DISTRIBUTION PANEL (TYPICAL LOCATION UNLESS SHOWN OTHERWISE), SEE ELECTRICAL SHEETS 5. GAS METER - GAS METER, SEE PLUMBING SHEETS 6. RTU - ROOF TOP HVAC UNIT CURB MOUNTED SCREENED BY PARAPET OR ATTACHED PRE-MANUFACTURED SCREEN, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 7. WH - ELECTRIC WATER HEATER, SEE ID, PLUMBING AND ELECTRICAL SHEETS 8. REF - REFRIGERATOR, SEE ID SHEETS 9. COOKTOP & HOOD - LISTED AND APPROVED RANGE TOP/OVEN AND HOOD EXHAUST VENT DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL AND ELECTRICAL SHEETS 10. MICRO - MICROWAVE, SEE ID SHEETS 11. DW - DISHWASHER, SEE ID SHEETS 12. WALL OVENS, SEE ID SHEETS 13. W/D - WASHER / DRYER ELECTRIC STACKED, VENT DRYER DIRECTLY TO EXTERIOR, SEE ID, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS 14. KITCHEN SINK TO BE UNDERMOUNT DISPOSAL AIR SWITCH ACTIVATED, SEE ID AND PLUMBING DRAWINGS 15. COUNTERTOPS TO BE SOLID SURFACE OR SIMILAR NON-ABSORBENT MATERIAL, SEE ID SHEETS 16. UPPER CABINET(S) LOCATIONS, SEE ID SHEETS 17. BASE CABINET(S) LOCATIONS, SEE ID SHEETS 18. BUILT-IN SHELVING, SEE ID, SHEETS 19. MIRROR LOCATIONS, SEE ID, SHEETS 20. SMOKE DETECTORS LOCATIONS, SEE ELECTRICAL SHEETS 21. WALL MOUNTED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 22. RECESSED LIGHT FIXTURE LOCATIONS, SEE ID, AND ELECTRICAL SHEETS 23. CEILING FANS IN FITNESS ROOM, PROVIDE REQUIRED BRACING, SEE ID, AND ELECTRICAL SHEETS 24. SEE EXTERIOR ELEVATIONS FOR STOREFRONT SIZING GENRAL PLAN NOTES:_______________________________ WALL TYPES INDICATED ON THESE PLANS TO BE WALL TYPE 1A AT LOCATIONS INDICATED ON SHEETS A1.11 AND A1.12 FSD AND FIRE RATED PLAN ELUX AT MCQUEEN 50 Exhibit Q: STREET SECTIONS ELUX AT MCQUEEN 51 Exhibit R: PARKING & TRASH LOCATION PLAN N ELUX AT MCQUEEN 52 Exhibit S: PRELIMINARY GRADING & DRAINAGE PLAN X X X X X X X X X X X X X X X X X X X X D X X X X X X X X X X X X X X X X X X X X X X X X X X X X D D D D D S S ELUX AT MCQUEEN 53 Exhibit T: PRELIMINARY PLAT X X X X X X X X X X X X X X X X X X X X D X X X X X X X X X X X X X X X X X X X X X X X X X X X X D D D D D S S ELUX AT MCQUEEN 54 Exhibit U: SOUTHERN BOUNDARY CROSS SECTION N