2020 Amendments to Chandler City Code Chapter 43, Section 43-4.5
{Public Record for Ordinance No. 4948}
Chandler City Code, Chapter 43 (Public Works and Utilities Department), Section 43-4.5 is
hereby amended by adding the following (additions in ALL CAPS, deletions in strikeout):
43-4.5. The following standards, details, specifications, and/or policies regarding public
works improvements are in effect in the City of Chandler:
A. City of Chandler Standard Details and Specifications. That certain document on file
with tl}e City Clerk marked, known and designated as "City of Chandler Standard Details
and Specifications", January^ 2021 Edition, is hereby adopted by reference and made a
part hereof as if set forth at length herein.
B. City of Chandler Technical Design Manual, Numbers 1 and 2: Water and Wastewater
System Design. That certain document on file with the City Clerk marked, known and
designated as "City of Chandler Technical Design Manual, Numbers 1 and 2: Water and
Wastewater System Design", January^ 2021 Edition, is hereby adopted by reference
and made a part hereof as though set forth at length herein.
C. City of Chandler Technical Design Manual, Numbers 3: Drainage Policies and
Standards. That certain document on file with the City Clerk marked, known and
designated as "City of Chandler Technical Design Manual, Numbers 3: Drainage Policies
and Standards", January^ 2021 Edition, is hereby adopted by reference and made a part
hereof as though set forth at length herein.
D. City of Chandler Technical Design Manual, Number 4: Street Design and Access
Control. That certain document on file with the City Clerk marked, known and designated
as "City of Chandler Technical Design Manual, Number 4: Street Design and Access
Control", January ^ 2021 Edition, is hereby adopted by reference and made a part
hereof as though set forth at length herein.
E. City of Chandler Technical Design Manual, Number 5: Traf ic Signal Design. That
certain document on file with the City Clerk marked, known and designated as "City of
Chandler Technical Design Manual, Number 5: Traffic Signal Design," January^ 2021
Edition, is hereby adopted by reference and made a part hereof as though set forth at length
herein.
F. City of Chandler Technical Design Manual, Number 6: Streetlight Design. That certain
document on file with the City Clerk marked, known and designated as "City of Chandler
Technical Design Manual, Number 6: Streetlight Design", January 2020 Edition, is hereby
adopted by reference and made a part hereof as though set forth at length herein.
G. City of Chandler Technical Design Manual, Number 7: Traf ic Barricade Design. That
certain document on file with the City Clerk marked, known, and designated as "City of
Chandler Technical Design Manual, Number 7: Traffic Barricade Design," January W-1-6
2021 Edition, is hereby adopted by reference and made a part hereof as if set forth at length
herein.
H. City of Chandler Technical Design Manual, Number 8: Landscape Design of Rights-of
Ways, Medians and Retention Basins. That certain document on file with the City Clerk
marked, known and designated as "City of Chandler Technical Design Manual, Number 8:
Landscape Design of Rights-of Ways, Medians and Retention Basins", May 2018 Edition,
is hereby adopted by reference and made a part hereof as though set forth at length herein.
I. MAG Uniform Standard Specifications and Details. That certain document on file with
the City Clerk marked, known and designated as Uniform Standard Specifications and
Details for Public Works Construction, Sponsored and Distributed by the Maricopa
Association of Governments,X 2021 Edition, is hereby adopted by reference and made
a part hereof as though set forth at length herein with the additions, insertions, deletions
and changes set forth below.
1. The Public Works and Utilities Director/designee is authorized to increase standard
street cross sections, both pavement and right-of-way widths, as necessary to maintain
required traffic service levels when a traffic analysis indicates the need for additional lanes
of traffic.
2. Where MAG refers to corrective actions for deviations from standards and provides
options for "When the contracting agency is the owner" or "When the contracting agency is
not the owner (i.e. permits)", the Public Works and Utilities Director/designee is authorized
to utilize any of the corrective actions listed regardless of whether the City is the
contracting agency or not.
J. [Reserved.]
K. Policy on Geometric Design of Highways and Streets. That certain document on file
with the City Clerk marked, known and designated as "The Policy on Geometric Design of
Highways and Streets," 2004 Edition, published by the American Association of State
Highway and Transportation Officials, is hereby adopted by reference and made a part
hereof as though set forth at length herein.
L. City of Chandler Manual on Stormwater Quality Protection. That certain document on
file with the City Clerk marked, known and designated as "City of Chandler Manual on
Stormwater Quality Protection, December, 2007 Edition," is hereby adopted by reference
and made a part hereof as if set forth at length herein.
Change Summary 2020.xlsx
Document No.
Title
Revision Summarx
Standard Details
C-112 Pg 1
ENGINEERED UTILITY BORE
Revision to Bore Profile Typ. Section to show City fiber conduit per
C-200 revision. Revision to title block for PQ 1 desiQnation.
New Pg 2 detail to illustrate minimum separation requirements
C-112 Pg 2
ENGINEERED UTILITY BORE
between City wet utility and 'Bore/Dry Private Utility" per MAG
Table 608-3.
C-113
TRASH RECEPTACLE ENCLOSURE
Revision to note 1 to correct spellina of enclosures
C-200
STANDARD UTILITY LOCATIONS
Revision to City fiber conduit (T.S.) location adding primary location
ARTERIAL STREETS
at R/W line and alternate location at 611 back-of-curb.
C-203
MAJOR ARTERIAL STREET TYPICAL
Revision to base course note no. 2A. "Thickness shall conform to
CROSS SECTION
COC Standard Detail C-239, 12" minimum.
C-203
MAJOR ARTERIAL STREET TYPICAL
Add note 7 pertaining to minimum 0.2% longitudinal grade
CROSS SECTION
consistent with other street cross section details.
Removing note regarding waiving sidewalk on one side of the
C-206
COLLECTOR STREET WITH MEDIAN
roadway. Due to onsite ADA route requirements, the City will now
TYPICAL CROSS SECTION
require sidewalks adjacent to all public streets in order to better
meet the intent of the ADA.
Removing note regarding waiving sidewalk on one side of the
C-208
INDUSTRIAL COLLECTOR STREET
roadway. Due to onsite ADA route requirements, the City will now
TYPICAL CROSS SECTION
require sidewalks adjacent to all public streets in order to better
meet the intent of the ADA.
Removing note regarding waiving sidewalk on one side of the
C-209
COLLECTOR BOULEVARD TYPICAL
roadway. Due to onsite ADA route requirements, the City will now
CROSS SECTION
require sidewalks adjacent to all public streets in order to better
meet the intent of the ADA.
Removing note regarding waiving sidewalk on one side of the
C-210
COLLECTOR STREET TYPICAL CROSS
roadway. Due to onsite ADA route requirements, the City will now
SECTION
require sidewalks adjacent to all public streets in order to better
meet the intent of the ADA.
C-239
DEPTH OF BASE COURSE MAJOR &
Revision to set 12" as min base thickness in chart. Revised note 2
MINOR ARTERIAL
to clarify under asphalt concrete surface.
Major update to existing detail meeting current construction
C-256
TYPICAL RAISED CROSSWALK
standards. New title "TYPICAL MID-BLOCK RAISED
CROSSWALK".
C-262
MANHOLE / WATER VALVE BOX CURB
NEW detail to realign curb & gutter where a manhole or water
REALIGNMENT
valve are in conflict
Revision to note no. 1 allowing use of compression fittings on 1"
C-301 Pg 1
WATER SERVICE INSTALLATION
services. Revision to note no. 3 adding use only approved meter
flanQe adaptor for reducinQ the service line.
C-301 Pg 1
WATER SERVICE INSTALLATION
Removing note at lower left restricting taps on 16" mains.
C-308
WATER PIPE BEDDING DETAIL
Updating notes to fully reference MAG Section 601 and City List of
Approved Products.
Added note 8 for Type 'B' adjustments pertaining to fiberglass
C-401
MANHOLE CONCRETE COLLAR AND
manholes with necks (typically around 3" tall above barrel) to
ADJUSTMENT TYPES
ensure no weight is on the neck. Revised note 6, adding "and
concrete collar installation."
C-402
SEWER PIPE BEDDING DETAIL
Revisions to move ABC to 1' above pipe, updating notes to fully
reference MAG Section 601 and City List of Approved Products.
C-510
TEMPORARY RETENTION BASIN
NEW detail for temporary retention basin grading and drainage,
MULCH DRYWELL
improving drainage and ongoing maintenance requirements.
Page 1 of 2
Change Summary 2020.xlsx
Technical Design Manuals
TOM #1&2
Water and Wastewater System Design
Revision to page 13, first paragraph, removing "Water services
mav not be installed on 16 inch water lines."
Revisions to page 32, Section J. Private Reclaimed Water System
TOM #1&2
Water and Wastewater System Design
design considerations, removing medium volume users consistent
with reclaimed water aqreement.
TDM#3
Drainage Policies and Standards
Revision to page 19, Section 6.11.1 Surface Basins, adding
reference to NEW detail C-510 for temporary retention basins.
Revisions to page 33 pertaining to traffic signal conduit and
TDM#4
Street Design and Access Control
interconnect conduit. Revise language to refer to TDM#5 for the
interconnect conduit reauirements.
Revision to page 30, Section 3.4, remove subgrade relative
compaction paragraph in favor of MAG standards. Relative
TOM #4
Street Design and Access Control
compaction under MAG 301.3 requires 95% below pavement, curb
& gutter, attached sidewalk, roadway shoulders, and other areas
within R/W subject to vehicular traffic, but allows 85% below
detached sidewalks not subject to vehicular traffic.
Various revisions related to fiber, equipment and conduit
requirements. Revisions to specify use of 2013 ADOT Standards
TDM#5
Traffic Signal Design
instead of current. ADOT recently changed their signal standards
and City wishes to continue using 2013 style poles/arms for
maintenance and interchangeability purposes. Minor updates to
TS-02, TS-07 and TS-08. Revised conduit notes on TS-14.
General cleanup including dept./division updates due to reog, title
changes, phone number updates, pronouns, consistency, etc.
More relevant revisions include: 1) Updating procedure to online
application submittal, review, and permit approval (instead of paper
TDM#7
Traffic Barricade Manual
or email submittals). 2) Changing advance notice required from 1
to 3 days for lane restrictions. 3) Changing advance notice required
from 3 to 5 days for alley closures. 4) Changing min 36 inch
accessible path width to 60 inch (or 48 inch with 60x60 inch
passing spaces every 200 feet) meeting ADA.
Specifications (Supplements to MAG)
CONCRETE CURB, GUTTER, SIDEWALK, Remove Section 340.3 supplement in favor of MAG subgrade
SECTION 340
SIDEWALK RAMPS, DRIVEWAY, AND
ALLEY ENTRANCE
compaction standards. Related to revision to TOM# 4, Section 3.4.
SECTION 355
UTILITY POTHOLES-KEYHOLE METHOD NEW supplement specification to ensure 1/2-sack CLSM is used
as backfill for pothole repairs (vs mechanical compaction).
Revision to replace existing Bore/Plan Profile supplement language
SECTION 608
HORIZONTAL DIRECTIONAL DRILLING
providing more clarity where City and MAG differ in particular with
the tables.
Page 2 of 2