JOB ORDER PROJECT AGREEMENT

Project Name: ARROWHEAD, FOLLEY, AND NOZOMI AQUATIC CENTERS
SAFETY IMPROVEMENTS

Project No, CS2201.401

This JOB ORDER PROJECT AGREEMENT (“Job Order") is made this day of 2022 (“Effective
Date”), by and between the City of Chandler, an Arizona municipal corporation, (City) and Caliente
Construction, Inc., an Arizona corporation, ("JOC Contractor") and is entered into pursuant to Job Order
Master Agreement No. JOC1904.401 (“JOC Master Agreement”). City and JOC Contractor may be referred to
individually as “Party” or collectively as “Parties”).

City and JOC Contractor, in consideration of the mutual covenants herein set forth, agree as follows:
RECITALS

A. On or about December 17, 2019, the Parties entered into the JOC Master Agreement, which terms and
conditions are made a part of and incorporated into this Job Order Project Agreement by this reference.

B. City proposes to engage JOC Contractor for ARROWHEAD, FOLLEY, AND NOZOMI AQUATIC CENTERS
SAFETY IMPROVEMENTS as more fully described in Exhibit "A", which is attached to and made a part of this
Job Order by this reference.

C. JOC Contractor is ready, willing, and able to provide the services described in Exhibit “A” for the
compensation and fees set forth and as described in Exhibit "B”, which is attached to and made a part of

this Agreement by this reference.

ARTICLE 1, DESCRIPTION OF WORK

The Parties enter into this Job Order Project Agreement for the ARROWHEAD, FOLLEY, AND NOZOMI
AQUATIC CENTERS SAFETY IMPROVEMENTS, Project Number CS2201.401. The scope of work consists of
improvements at Arrowhead, Folley, and Nozomi Aquatic Centers, all as more particularly set forth in
Exhibit “A” attached hereto and incorporated herein by reference.

The JOC Contractor will not accept any change of scope, or change in contract provisions, unless issued in
writing, as a contract amendment or change order and signed by the authorized signatories for each party.

Performance ahd Payment Bonds, as set forth in Exhibit “C” and Exhibit “D” respectively attached hereto
and incorporated herein by reference, will be due prior to execution of each Job Order Project Agreement
in the full amount of each Job Order.

City of Chandler Job Order Project Agreement Bat A-1
Public Works & Utilities Department, Capital Projects Division it

Project Name: ARROWHEAD, FOLLEY, AND NOZOMI AQUATIC CENTERS SAFETY IMPROVEMENTS

Project No.: CS2201.401 .

Rev. 9/18/2020

At project completion, JOC Contractor must complete Contractor's Affidavit Regarding Settlement of Claims
and Certificate of Completion, ‘as set forth in Exhibit “E” and Exhibit “F” respectively attached hereto and
incorporated herein by reference.

ARTICLE 2. PROJECT PRICE

City will pay JOC Contractor for completion of the Work in accordance with the JOC Master Agreement a fee
not to exceed the Guaranteed Maximum Price of $86,614.33 Dollars determined and payable as set forth
in JOC Master Agreement and Exhibit “B” attached hereto and made a part hereof by reference.

ARTICLE 3. CONTRACT TIME & SCHEDULE

JOC Contractor agrees to complete all Construction within 60 calendar days from the Notice to Proceed
(NTP) Date.

ARTICLE 4. PARTICIPANTS

CITY: Construction Project Manager: Jason Garcia
Phone: | 480-782-3453
Email: | Jason.garcia@chandleraz.gov

JOC CONTRACTOR: Caliente Construction, Inc.
485 W. Vaughn St.
Tempe, AZ 85283
JOC Contractor Representative: Lorraine Bergman
Phone: | 480-894-5500
Email: | Ibergman@calienteconstruction.com

SIGNATURE PAGE TO FOLLOW

City of Chandler Job Order Project Agreement A-1
Public Works & Utilities Department, Capital Projects Division

Project Name: ARROWHEAD, FOLLEY, AND NOZOMI AQUATIC CENTERS SAFETY IMPROVEMENTS

Project No.: CS2201.401

Rev. 9/18/2020

IN WITNESS WHEREOF, the Parties have executed this Job Order as of the Effective Date.

“CITY”
CITY OF CHANDLER:

MAYOR

Recommended By:

Date

“JOC CONTRACTOR”
Caliente Construction, Inc.:

Print Name

President/CEO

a age 01/1 1/2022

Date

“Andrew Goh, P.E.
CIP City Engineer

APPROVED AS TO FORM:

Title

ay lf Corporation
ih, Riya

City Attorney
By:

ATTEST:

City Clerk

ADDRESS FOR NOTICE
City of Chandler

P.O. Box 4008, Mail Stop 407
Chandler, AZ 85244-4008

City of Chandler Job Order Project Agreement

“SEAL |

Public Works & Ulilitlas Department, Capital Projects Division
Project Name: ARROWHEAD, FOLLEY, AND NOZOMI AQUATIC CENTERS SAFETY IMPROVEMENTS

Project No.; CS2201.401
Rev. 9/18/2020

Betfetary

ADDRESS FOR NOTICE

Caliente Construction, Inc.

485 W. Vaughn St.
Tempe, AZ_ 85283

AA

EXHIBIT A
SCOPE OF WORK

City of Chandler Job Order Project Agreement
Public Works & Utilities Department, Capital Projects Division

Project Name: ARROWHEAD, FOLLEY, AND NOZOMI AQUATIC CENTERS SAFETY IMPROVEMENTS
Project No.: CS2201.401 ‘

Rev. 9/18/2020

AA

Caliente Construction inc.

General Construction - Construction Management - Design/Build - Facilities Management

R1 December 7, 2021

Ivan Magana, PE

Project Manager

City of Chandler

Public Works and Utilities Dept. - Capital Projects Div.
215 East Buffalo Street

Chandler, AZ 85225

RE: City of Chandler JOC 1904.401 - CS2201.401 Arrowhead, Folley and Nozomi Safety Improvements
Surge pit and drain improvements R1
Mr. Magana,

Thank you for the opportunity to provide our revised proposal for the CS2201.401 Arrowhead, Folley and Nozomi Safety
Improvements Surge pit and drain improvements R1 Project.

We have based the attached proposal on information received, emails and site visit held with the City of Chandler.
The price is $ 86,614.33. See attached estimate with bid tabulations and subcontractor back-up for further details.
Please contact me at your convenience should you have any questions.

Best Regards,

| ene

Justin Miller
Caliente Construction Inc.

One of the Valley's Healthiest Employers
485 West Vaughn, Tempe, Arizona 85283-3672 Phone: (480) 894-5500 Fax: (480) 894-2323
BENG AZ ROCO091625 AZ ROCO98769 AZ ROC164561 CA 770323 UT 4741522-550 NV 0078132
ID RCE-28529 NM 85371 CO 233580 MT 159637

We build more than structures; we build confidence and relationships that last”

Caliente Construction Inc.

General Construction - Construction Management - Design/Build - Facilities Management

EXHIBIT A
SCOPE-OF WORK
PROJECT:
City of Chandler JOC 1904.401 - CS2201.401 Arrowhead, Folley and Nozomi Safety Improvements
Surge pit and drain improvements R1

General Requirements:
1) Provide office support, supervision, overhead/profit, taxes based on MRRA, insurances, and bond.

2) Provide temporary protection as required.
Construction:

Arrowhead Pool:
1) Make Safe and Drain Surge Pit Water Level w/ coordination form COC Aquatics
2) Demo Existing Articulating Float Valves
3) Furnish and Install (2) New Articulating Float Valves
4) Clean, Prep and apply Thoroseal Product to Surge Pit Walls and Floors.

Folley Pool:
1) Make Safe and Drain Surge Pit Water Level w/ coordination form COC Aquatics
2) Demo Existing Articulating Float Valves
3) Furnish and Install (2) New Articulating Float Valves
4) Clean, Prep and apply Thoroseal Product to Surge Pit Walls and Floors

Nozomi Aquatic Center:
1) Confined Space Requirements per Industry/OSHA Standards
2) Make Safe and Drain Surge Pit Water Level w/ coordination form COC Aquatics
3) Demo Existing Articulating Float Valves
4) Furnish and Install (2) New Articulating Float Valves
5) Clean, Prep and apply Thoroseal Product to Surge Pit Walls and Floors.

Project Duration:
Project duration is 3-5 Days onsite construction at each location after all materials are procured and pools are drained; testing of

valves to be completed after pool is filled by COC (current lead time for Valves is 3 Weeks from time of order).

Clarifications/Exclusions:

See attached estimate.

: Of the Valles Healthiest Employers

485 West Vaughn, Temps, Atizona 85283-3672 Phone : (480) 894-5500 Fax : (480) 894-2323

AZ ROC091625 AZ ROCO98769 AZ ROC164561_ CA 770323. UT 4741522-550 NV 0078132 ; a
ID RCE:28529 NM 85371 CO 233580 MT 159637 ‘

“We build more than structures; we build confidence and relationships that last”

COC JOC 1904.401 CS2201.401 Arrowhead, Folley and Nozomi Safety Improvements

€
Caliente

Ass
1

Oahwn

Exc!
1
2

NOOK W

Allo’
1

umptions / Clarifications
Proposal based on onsite Project Duration of (3-5 Days Per Site) after procurement of materials
and draining of pool.

Proposal based on Normal Working Hours M-F
Proposal based on COC Aquatics Facilitating Drain Down And Fill
Proposal based on access to surge pit areas
Proposal based on replacement of (2) valves per Location.
Proposal includes reccomended scope to clean, prep, and Thoroseal Surge Pit at each site.
Proposal includes testing of valve operation after pool is filled by COC.
lusions
Design Services, Permits and/or Permitting Fees
Asbestos Testing and/or Abatement and/or Removal of Hazardous Materials (Current
Report/Survey to provided by COC prior to start of Demolition).
Excludes Water Chemicals or Treatments
Excludes Piping or Modifications unless noted above
Modifications to Exsiting Equipment or Electrical other than stated in scope.
Testing and Balancing of Pool Chemicals
Badging or Special Background Checks and/or associated costs
wances (Not Included in Base Bid; No Markups)

CONSTRUCTION ALLOWANCE $ 7,000.00

Data Sheet

ME ADE
FILTER

A NORTH AMERICAN FILTRATION COMPANY

FV-S Float Valve Single Arm - Single Float

For end of open pipe installation only

Not for in-line use
For 4”, 6” and 8” pipe only
Bolt pattern - ANSI 150

MATERIAL
Valve body - corrosion grade Isophthalic Polyester
Valve disc - corrosion grade Isophthalic Polyester
FloatArm - Solid 316 SS
Valve shaft - Solid 316 SS
Hardware - 316SS
Float Ball - polyethylene
DESIGN

SS arm threaded 3/8” for float attachment

Valve disc molded onto valve shaft
Approximately 20% flow when closed
Arm located on left (looking into flow)

i \
( ;——
Ns i
\ P;
ID A B Cc D E G K L M N P
4 | 942" | 7172" | 23” | 65/8" | 10 1/8" | 34” " a” | ae" | 12" | 26"
“oe [4142 | 942” | 23" | 7578" | 14478" | 34” 1" 8” | ae" | 12" | 26"
8” | 14” |113/4"| 23” | 87/6" | 1223/8" | 34” | 14/2" | 8” | 58” | 3/4” | 26"

Mer-Made Filter :

Division of North American Filtration Inc. ——"

11746 Charleston-Augusta Highway
Ph 803.793.4265 Fax 803.793.4332

Denmark, SC 29042
www.mermade.com

THOROSEAL®

Waterproof cement-based coating

for concrete and masonry

degussa.

Construction Chemicals

PRODUCT DATA

Cementitious
Waterproofing

7. 07160

Description

Thoroseal® is a Portland-cement-
based coating for concrete and
masonry that resists both positive
and negative hydrostatic pressure.
Polymer-modified with Acryl 60°,
Thoroseal® creates a low-
maintenance and highly durable
waterproof barrier.

Yield

225 f?/50 Ib (20.9 m*/22.7 kg) bag
as a base coat at 1/16" (1.6 mm)
dry-film thickness.

450 ft?/50 Ib (41.8 m*/22.7 kg) bag
as a topcoat at 1/32" (0.8 mm)
dry-film thickness.

Coverage will vary depending on
surface texture and porosity.
Packaging

THOROSEAL®

10 Ib (4.5 kg) cans for Thoroseal®
white and standard gray only

30 Ib (13.6 kg) polyethylene-lined
bags for Thoroseal® white and
standard gray only

50 Ib (22.7 kg) polyethylene-lined
bags for Thoroseal® white, standard
gray, all landscape standard colors
and custom colors

60 Ib (27.2 kg) pails for Thoroseal®
white, standard gray, Navajo white,
pearl gray, Thoro® gray, and custom
colors

Features
e Waterproof

¢ Resistant to both positive and negative
hydrostatic pressure

¢ NSF approved (white or gray, only)
e Breathable

¢ Compatible with high-performance coatings
¢ Aesthetically beneficial

e Aesthetically superior

Benefits

Protects building interiors from dampness and
moisture damage

Suitable for use below grade interior and exterior
and in water-treatment construction

Use in potable water tanks

Allows interior moisture to escape without
damaging coating

Accepts a wide range of architectural coatings
and textured finishes

Hides minor surface defects and blemishes in
architectural concrete

Available in 10 standard colors and in

custom colors

ACRYL 60°

1 quart (0.9 L) bottles

1 gallon (3.8 L) bottles

5 gallon (18.9 L) pails

30 gallon (113 L) drums

55 gallon (208 L) drums

Color

White and standard gray (this color is not uniform)

10 Landscape standard colors : bone, dijon,
French vanilla, good earth, light khaki, Thoro® gray,
Navajo white, parchment, pearl gray, and putty tan

Custom colors are available for 5,000 Ibs (2268 kg)
minimum order.

Shelf Life

1 year when properly stored

Storage

Transport and store in unopened containers and keep
ina clean, dry condition protected from rain, dew,
and humidity. Do not stack bags more than 2 pallets
high. If dry onsite storage of bags is unavailable or if
project is located in a very wet, humid climate zone,
then specify Thoroseal® packaged in 60 Ib (27.2 kg)
metal pails. Store Acryl 60° in similar conditions. Do
not allow Acryl 60° to freeze.

Where to Use
APPLICATION

© Alternative to mechanical finishing or rubbing
of concrete

© Waterproofing basement and retaining walls
© Foundations

© Bridges and tunnels

e Water cisterns

LOCATION

© Vertical and light-pedestrian horizontal surfaces
e Interior and exterior

© Above and below grade

SUBSTRATE

¢ Cast-in-place and precast concrete

¢ Block, brick, and porous stone

www.DegussaBuildingSystems.com

THORO* PRODUCT DATA
THOROSEAL®

Technical Data
Composition

Thoroseal® contains cement, graded sand, and
proprietary additives.

Test Data
PROPERTY RESULTS TEST METHODS
Initial Set, min, 10 Lab Method
at 70° F (21° C), 50% rh
Final Set, 30 Lab Method
at 70° F (21° C), 50% rh
Density, (cured), Ibs/ft® (kg/m*) 129 (2,080) Lab Method
Positive resistance to 752 CRD C 48, modified

hydrostatic pressure, hrs,

at 200 psi (1.4 MPa), 461 head ft,
air cured at 70° F (21° C),

50% rh

No leakage, no softening

Negative resistance to
hydrostatic pressure, hrs,

at 200 psi (1.4 MPa), 461 head ft,
air cured at 70° F (21° C),

50% rh

664
Limited dampness

CRD C 48, modified

Potable water (direct contact) Suitable; BS6920 (British standard)
approved NSF Standard 61
Water absorption, %, 3.6 ASTM C 67 (Section 7.3)
boiling water submersion at 24 hours
Compressive strength, psi (MPa) ASTM C 109
7 days 4,200 (29)
28 days 6,030 (42)
Flexural strength, psi (MPa) ASTM C 348
7 days 360 (2.5)
28 days 1,027 (7)
Tensile strength, psi (MPa) ASTM C 190
7 days 250 (2)
28 days 440 (3)
Modulus of elasticity, psi (MPa) ASTM C 469
28 days 2.72 x 10° (1.87 x 10')
Artificial weathering, hrs
Xenon Arc 5,000 = No failure ASTM G 26
Carbon Arc 500 = No failure ASTM G 23
Adhesion strength, psi (MPa) 418 (2.9) Test by tensile bond
Artificial weathering, No cracking, Atlas Type DMC
loss of adhesion, weatherometer
checking, or other defect
Freeze/thaw resistance, No change ASTM C 666 (Procedure B)
200 cycles
Salt spray resistance, No defect ASTM B 117
300 hours
Carbon Dioxide (CO), 1/16 (1.6) Lab Method
in (mm) Equivalent to 3/4" (19 mm) Diffusion
new concrete
Permeance, perms 12 (0.10698) ASTM E 96

(metric permeability)

18 x 10° resistance

. (water-vapor transmission)

Swedish standard SS-02-15-82

THORO® PRODUCT DATA

THOROSEAL®
Test Data, continued
PROPERTY RESULTS TEST METHODS
Wind-driven rain, hrs 8 = excellent Fed. Spec. TT-P-0035
(Para 4.4.7)
Coefficient of thermal expansion, 6.99 x 10% (5 x 10”) ASTM C 531

in/in/° F (mm/mm/? C), at 28 days

Impact strength No chipping Fed. Spec. TT-P-0035
(Gardener impact tester) (Cement paints para. 3.4.8)
Hardness, (Barber Colemen Impressor) Fed. Spec. TT-P-0035
Requirement min = 30, max = 60 (para 4.4.9)
7 days 35
14 days 47
21 days 52
Abrasion resistance, Passed Fed. Spec. TT-P-141B
3,000 L sand
Reflectance ASTM D 2244 using
Gray Thoroseal® 64.2 Hunterlab D-25 meter
White Thoroseal? 88.1

Fungus resistance,

No growth; meets all

Fed. Spec. TT-P-29B

at 21 days requirements

Surface burning characteristics ASTM E 84
Flame Spread 0
Smoke developed 5

Fire Propagation Index = 1.5 BS476: Part 6:1981
Flame spread Class 1 BS476: Part 7:1971

Test results are averages obtained under laboratory conditions. Reasonable variations can be expected.

How to Apply
Surface Preparation

1. Surface preparation is extremely important for
proper adhesion. Substrates must be sound and
free of dust, dirt, laitance, paints, oils, grease,
curing compounds, or any other contaminants.
Verify substrate has properly cured. Concrete should
obtain 80% of design strength, typically achieved
within 3 — 14 days. If efflorescence is present,
mechanically remove it before proceeding. For
extreme cases where this is not adequate, contact
Technical Service.

2. Patch all holes and cracks before installation.

3. Relieve hydrostatic pressure in concrete block
with weep holes.
4. Roughen or brush blast extremely smooth

surfaces such as precast and cast-in-place concrete
to ensure good mechanical adhesion of Thoroseal®.

Mixing

1. Mix Thoroseal® with a mixing liquid consisting of
a blend of Acryl 60° diluted with water. Maximum
dilution ratio is 1 part Acryl 60° to 3 parts water.
Approximately 6 quarts of mixing liquid is needed
per 50 Ibs of Thoroseal® powder. Up to 2 additional
quarts of mixing liquid may be added when using as
a rubbing compound.

2. For best results, mechanically mix Thoroseal?
with a slow-speed drill and mixing paddle. Gradually
add the powder to the mixing liquid while drill is
running.

3. When properly blended, Thoroseal® will have
the lump-free consistency of smooth, heavy batter.

4. Allow the-Thoroseal® and Acryl 60° mixture to
rest undisturbed for a minimum of 10 minutes to
fully wet out all the powder. Then remix the wet
mixture and apply. A small amount of mixing liquid
can be added to this remixing.

5. Pot life is 60 — 90 minutes at 70° F (21° C). At
high temperatures and low relative humidity, pot
life can be significantly less.

Application

1. Apply Thoroseal® with a Thoro® brush or broom
or equivalent stiff fiber brush or by textured spray
equipment. Spray applications of the first coat
require back brushing or brooming to properly fill
voids and achieve uniformity.

2. Completely dampen the substrate with water
before application starts. Do not saturate the
substrate, but keep it cool and damp throughout the
application.

3. It is essential to work first coat thoroughly into
the substrate to completely fill and cover all voids,
holes, and nonmoving cracks. Finish with a
horizontal stroke for an even coat.

THORO* PRODUCT DATA
THOROSEAL®

4. Allow to cure 24 hours, then apply the second
coat and finish with a vertical stroke. Above grade,
the second coat can be replaced with a Thoro®
high-build architectural coating to achieve better
color uniformity.

5. On block or masonry walls, allow 5 — 7 days
before applying second coat to eliminate joint read
through.

Specific Applications
Above-grade interior or exterior applications in

positive pressure situations (direct contact with rain
or standing water with a low head of pressure)

1. A50 Ib (22.7 kg) bag of Thoroseal® will provide
the following coverage at the designated material
usage.

Recommended coverage:

¢ First Coat: 2 Ibs/yd? (1.1 kg/m’) =
225 ft?/50 Ib bag (20.9 m*/22.7 kg bag)

© Second Coat: 1 Ib/yd? (0.54 kg/m’) =
450 ft?/50 Ib bag (41.8 m*/22.7 kg bag)

© Total: 3 Ibs/yd? (1.6 kg/m’), cured nominal
thickness of 1/16" (1.6 mm).

Coverage will vary depending on surface texture
and porosity.

2. A3 Ibs/yd? (1.6 kg/m’) application rate does

not eliminate surface irregularities such as struck
mortar joints. To hide surface irregularities, spray
and back-brush a base coat of Thoroseal® at

2 Ibs/yd? (1.1 kg/m2) and allow it to cure for 5-7
days. Then spray apply and back trowel a topcoat of
Thoroseal® Plaster Mix (see Form No. 1019908) at
an application rate of 9 Ibs/yd? (4.9 kg/m’).

BELOW-GRADE INTERIOR APPLICATIONS
1. The standard application is 3 Ibs/yd? (1.6 kg/m’).

2. For high hydrostatic pressure conditions (over
15 psi [0.10 MPa}), increase application rate to
4 |bs/yd? (2.2 kg/m*) and waterproof from the
positive side wherever possible.

BELOW-GRADE EXTERIOR APPLICATIONS

1. Use Thoroseal® Foundation Coating (see Form
No. 1019907) For high hydrostatic pressure
conditions (over 15 psi [0.10 MPal), apply a base
coat of Thoroseal® Foundation Coating at 2 Ibs/yd?
(1.1 kg/m?) and allow to cure for 5-7 days.

2. Then apply a topcoat of Thoroseal® Plaster Mix
at 12 Ibs/yd? (6.5 kg/m’). A steel trowel finish is
recommended.

3. For both below-grade interior and below-grade
exterior applications where water might move
between vertical walls and slab or footer, it is
recommended to cut out and place a Waterplug®
cove at the wall and floor junction prior to the
application of the Thoroseal® base coat.

4. Thoroseal® can be covered with extruded
polystyrene insulation board during the second coat
application. The board must be fully coated with
Thoroseal® and embedded into the still-wet coating
already in place on the walls. Exercise care when
placing the coated board because it should not be
moved or slipped. Once placed, do not move the
board. After curing, prepare the above-grade
portions of the boards by roughening or removing
the surface skin and then coating with Thoroseal®
to protect them from UV light degradation.

WATERPROOFING POTABLE WATER TANKS
OR RESERVOIRS

1. Install Thoroseal® as directed in the general
Application instructions.

2. After Thoroseal® has fully cured, wash down the
Thoroseal® surface with saline solution (salt brine,
1 Ib salt per 1 gallon water).

3. Leave saline solution on the entire Thoroseal®
surface for at least 24 hours.

4. Rinse off saline solution completely. If needed,
reapply saline solution until final rinse water is
completely clean and clear.

Color Uniformity

With any cementitious product, such as Thoroseal®,
it may be difficult to achieve color uniformity due to
weather and substrate variability. For this reason, it
may be necessary to apply a topcoat of a Thoro®
architectural coating.

Clean Up

Promptly clean hands and all tools with warm
water while product is still wet. Cured material
may only be removed mechanically.

For Best Performance

e Thoroseal® must be modified with Acryl 60° to
achieve the properties listed in the technical
data section.

¢ Do not apply to substrates with active water
leaks or moving cracks; patch all leaking static
cracks and holes with Waterplug®. Repair any
other nonmoving cracks or voids with the
appropriate Thoro® repair product and repair all
moving cracks or voids with appropriate sealant.

e Maintain or place expansion and control joints
as necessary.

Do not apply in rain or when rain is expected
within 24 hours. Do not apply above 90° F (32° C)
or below 40° F (4° C) or when temperatures are
expected to fall below 40° F (4° C) within 24
hours. For hot and cold temperature applications,
store Thoroseal®, Acryl 60° and water at 50° F
(10° C) to 70° F (21° C) before use.

Hot substrates will effect working time and
material strength.

Variations between inside and outside
temperatures may result in condensation on
below-grade walls treated with Thoroseal®.
This can be alleviated by assuring that adequate
ventilation exists.

Windy, dry, or hot conditions may require
rewetting of Thoroseal® during cure and the use
of polyethylene barriers.

Before specifying Thoroseal® for water-retaining
structures, conduct tests to determine water
quality. Thoroseal® is not intended for
continuous contact with acid or sulfate-
containing water. Very soft water will have an
adverse effect on Thoroseal?.

Service temperatures: immersion, up to 140° F
(60° C); cleaning water, up to 200° F (93° C);
dry air, up to 220° F (104° C).

On all projects, it is recommended that a sample
be prepared on site and approved prior to the
commencement of the work. The site sample
should confirm the color, texture and
workmanship required until the job is finished
and accepted. Retain the sample until final
approval is secured.

Allow Thoroseal® to cure 7 — 10 days before
immersion in water.

Make certain the most current versions of
product data sheet and MSDS are being used;
call Customer Service (1-800-433-9517) to
verify the most current version.

Proper application is the responsibility of

the user. Field visits by Degussa personnel
are for the purpose of making technical
recommendations only and not for supervising
or providing quality control on the jobsite.

Health and Safety
THOROSEAL®
Caution

Thoroseal® contains calcium hydroxide, crystalline
silica, iron (Ill) oxide monohydrate, and Portland
cement.

Risks

Product is alkaline on contact with water and may
cause injury to skin or eyes. Ingestion or inhalation
of dust may cause irritation. Contains small amount
of free respirable quartz which has been listed as a
suspected human carcinogen by NTP and IARC.
Repeated or prolonged overexposure to free
respirable quartz may cause silicosis or other
serious and delayed lung injury.

Precautions

KEEP OUT OF THE REACH OF CHILDREN. Avoid
contact with skin, eyes and clothing. Prevent
inhalation of dust. Wash thoroughly after handling.
Keep container closed when not in use. DO NOT
take internally. Use only with adequate ventilation.
Use impervious gloves, eye protection and if the
TLV is exceeded or used in a poorly ventilated area,
use NIOSH/ MSHA approved respiratory protection
in accordance with applicable federal, state and
local regulations.

First Aid

In case of eye contact, flush thoroughly with water
for at least 15 minutes. In case of skin contact, wash
affected areas with soap and water. If irritation
persists, SEEK MEDICAL ATTENTION. Remove and
wash contaminated clothing. If inhalation causes
physical discomfort, remove to fresh air. If discomfort
persists or any breathing difficulty occurs or if

swallowed, SEEK IMMEDIATE MEDICAL ATTENTION.

Refer to Material Safety Data Sheet (MSDS) for
further information.

Proposition 65

This product contains material listed by the state of
California as known to cause cancer, birth defects,
or other reproductive harm.

VOC Content

0 Ibs/gal or 0 g/L, less water and exempt

solvents.

For medical emergencies only,
call ChemTrec (1-800-424-9300).

‘THORO® PRODUCT DATA
THOROSEAL®

‘THORO* PRODUCT DATA
THOROSEAL®

Degussa Building Systems
‘889 Valley Park Drive

Shakopee, MN, 55379
www.degussabuildingsystems.com

‘Customer Service 800-433-9517
Technical Service 800-243-6739

LUMITED WARRANTY NOTICE Every reasonable effort is made to apply Degussa exacting standards both in the manufacture of our products and inthe information which we issue conceming these products and their use. We
‘warrant our Froducts to ba of good quality and will replace or, at our election, refund the purchase price of any products proved defective. Satisfactory results depend not onty upon quality products, but also upon many factors
bbayond our contol. Therefore except for such replacement or refund, Degussa MAKES NO WARRANTY OR GUARANTEE, EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR.
(MERCHANTABILITY, RESPECTING ITS PRODUCTS, and Degussa shall have no other laity with respect thereto. Any claim regarding product defect ust be received in writing within one (1 year from the date of shipment. No
claim will ba considered without such writ notice or afte the specified time interval. User shall determine the suitability ofthe froducts forthe intended use and assume all risks and liability in connection therewith. Any
authorized change inthe printed recommendations conceming the use of ou products must bear the signature ofthe Degussa Technical Managec
Tis information and all futher technical advice ae based on Degussa’ present inowiedge and exparence, However Degussa assumes no Fabilty fr providing such infomation and aches including the extent to which such information
and advice may relate to existing third party intellectual property rights, especially patent rights. In particular, Degussa disclaim all WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF
FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, DEGUSSA SHALL NOT BE RESPONSIBLE FOR CONSEQUENTIAL, INDIRECT OR INCIDENTAL DAMAGES {INCLUDING LOSS OF PROFITS) OF ANY KIND. Degussa reserves
the tight to make any changes according to technological progress or further developments Iti the customers responsbilty and obligation to carefully inspect and tet ny incoming goods. Performance of the products) described herein
shoul be verified by testing and cried ou erly by qualified experts tis te soe responsiblity ofthe custrer to cany out and arrange for any such testing Rfeence to trade nares used by ober companies is nether a tecormendation,
rar an endorsement of any product and does not imply that similar products coud not be used

Fo1m No, 1019906 9/03 (Replaces 1/02) © 2003 Degussa

For professional use only. Not for sale to or use by the general public. finted on recycled paper including 10% post-consumer fiber. Printed in USA.

Justin Miller

From: Jeffrey Iverson <jeff@hydrocon.com>

Sent: Wednesday, October 27, 2021 10:45 AM

To: Justin Miller

Cc: Curt Lonsdale

Subject: RE: Bid Invite: COC JOC CS2201.401 Arrowhead, Folley & Nozomi...

Good morning Justin,

Per our conversation, Shasta will not be submitting a proposal on this project due to current work load. It sounds like
you have found qualified and capable contractors to complete the work, of which already have experience installing the
exact systems the City of Chandler wants on previous projects.

Thanks for the opportunity and we hope to work with you and your team again in the near future.

jeffrey iverson
480.776.0155 x102 office
480.776.0157 fax

Shastazy

Crcunverreitt & Olpraypie

From: Justin Miller (Caliente Construction Inc.) <team@buildingconnected.com>
Sent: Wednesday, October 6, 2021 1:32 PM

To: Jeffrey Iverson <jeff@hydrocon.com>

Subject: Bid Invite: COC JOC CS2201.401 Arrowhead, Folley & Nozomi...

Justin Miller from Caliente Construction Inc. has invited you to bid on

COC JOC CS2201.401 Arrowhead, Folley &
Nozomi Safety Improvements: Swimming Pools

View this RFP | View Bid Form

Already know if Shasta Industries will bid on this RFP? Let Justin Miller at
Caliente Construction Inc. know:

Bidding || Not Bidding |} Not Sure

Project Details

Location: AZ, United States of America

Bid Due: October 11, 2021

Caliente Construction would like to invite you to submit a proposal on the COC JOC
CS2201.401 Arrowhead, Folley & Nozomi Safety Improvements project.

** This is a Caliente Cons...

View all files and project details »

Client Details

Lead: Justin Miller
Project Manager « +1 480-894-5500 « jmiller@calienteconstruction.com

Caliente Construction Inc.
485 W Vaughn St, Tempe, AZ 85283, USA

www.buildingconnected.com support@buildingconnected.com
© Copyright 2021 BuildingConnected.com. All Rights Reserved.
925 Mission St, San Francisco, CA 94103

EXHIBIT B
FEE SCHEDULE

City of Chandler Job Order Project Agreement

Public Works & Utilities Department, Capital Projects Division

Project Name: ARROWHEAD, FOLLEY, AND NOZOMI AQUATIC CENTERS SAFETY IMPROVEMENTS
Project No.: CS2201.401

Rev. 9/18/2020

B-1

Caliente Construction Inc.

General Construction - Construction Management - Design/Build - Facilities Management

EXHIBIT "B"

COC JOC 1904.401 CS2201.401 Arrowhead, Folley and Nozomi Safety
Improvements R1

JOB ORDER COST PROPOSAL

SUMMARY SHEET
12/7/2021
Negotiated Prices
Price of Subcontractor(s) $ 56,977.77
Price of Subconsultant(s) $ -
General Conditions $ 13,370.00
Preconstruction Labor (if applicable) $ -
Construction Labor (if applicable) $ -
SUBTOTAL (NEGOTIATED PRICES):| $ 70,347.77
Overhead and Profit (Coefficient per Job Order Master Agreement) [ 10.00% $ 7,034.78
TOTAL (NEGOTIATED PRICES + OVERHEAD & PROFIT):|} $ 77,382.55
Insurance, Bonds, & Taxes
Sales Tax Percentage (Current Tax Rate) MRRA 0.000% $ -
General Liability Insurance Percentage (Actual Cost per Job Order) 1.00% $ 703.48
Builder's Risk Insurance Percentage (Actual Cost per Job Order) 0.50% $ 351.74
Payment Bond (Actual Cost per Job Order) 1.50% $ 1,176.57
Performance Bond (Actual Cost per Job Order) INC 0.00% $ -
SUBTOTAL (INSURANCE, BONDS, & TAXES): $ 2,231.79
COMBINED TOTAL (TOTAL + INSURANCE, BONDS, & TAXES):| $ 79,614.33
City's Allowance $ 7,000.00
TOTAL JOB ORDER:| $ 86,614.33

Per the Job Order Master Agreement - [his Fee lable includes all fees, costs, insurance and bond premiums, allowances,
construction contingency, and taxes of any type necessary to fully, propertly and timely perform and construct the Work.
Also per the Job Order Master Agreement - For any portion of the Work which, either through this Contract, Change Order or
otherwise, is performed and paid for on a cost, or time and materials basis, the costs may be reimbursed to JOC Contractor
and chargeable against the Contract Price will be determined as set forth in MAG 109.5.

mA #1 Tenant impruvenent Corfracter In Arizona 20%6, 2017, 2018 & #1 General Contactar in Artzons 2017; 20%8, 2015
certifred 2008 Tere Business Excolonoe Award Winner
WBENG 485 V/, Vaughn Strect, TeTeo, AZ 85283 / Bhoee; (420) BIM-5500/ Fax: (420) BM.2323
J AZROCONGIS. AZ RCCORETED. AZ RCCIGASH! . CA 770923 UT 4741592-520
ID RICE.26525.. Nit US371. CO 251580. NT GOGIT. CR 210576 . Yu GOK-190-824

“We build more than structures; we build confidence and relationships that last”

€
Caliente

Construction Inc.

COC JOC 1904.401 CS2201.401
Project: Arrowhead, Folley and Nozomi Safety
Improvements R1

100 Building Sq. Ft.

Owner: City of Chandler - Site Sq. Ft.
Architect: NIA 0.00 Site Acres
Bid Date: 4217/2021 RFI(s): 00000 Permit Set
Taxing Jurisdiction: Chandler Addendum(s): 00000
MRRA or TPT: MRRA
DESCRIPTION TOTALS
DIVISION 1 GENERAL CONDITIONS $ 13,370.00
DIVISION 13 SPECIAL CONSTRUCTION $ 56,977.77
Subtotal of Cost Of Work $ 70,347.77
IOVERHEAD/PROFIT 10.00% $ 7,034.78
GENERAL LIABILITY INSURANCE 1.00% $ 703.48
BUILDERS RISK INSURANCE 0.50% $ 351.74
BONDING FEES 1.50% $ 1,176.57
CONSTRUCTION ALLOWANCE LS $ 7,000.00
TAX (Chandler 5.070%) MRRA (by subcontractors) 0.000% $ -
TOTAL COST $ 86,614.33

@

Caliente COC JOC 1904.401 CS2201.401 Arrowhead, Folley and Nozomi Safety Improvements
Construction Inc.

General Conditions

3 Weeks
DATE: 12/7/2021 21 Calendar Days
CODE ITEM QTY TYP RATE SUBTOTAL

GENERAL CONDITIONS $ 12,620.00
00-1040 }| Project Manager 0.40 WK $ 4,200.00 | $ 1,680.00
00-1052 | Assistant Project Manager 0.30 WK $ 3,200.00 | $ 960.00
00-1047 | Project Coordinator 0.20 WK $ 2,400.00 | $ 480.00
00-1045 | Superintendent 2.50 WK $ 3,800.00 | $ 9,500.00

GENERAL REQUIREMENTS $ 750.00
00-1096 | Safety / Temp Protection 1.00 LS $ 750.00 | $ 750.00

GENERAL CONDITIONS TOTAL $ 13,370.00