Extracted text (via pymupdf)
19628 characters
PLH22-0024 Cornerstone Ranch Comprehensive Sign Program N N CORNERSTONE RANCH DOBSON+OCOTILLLO CORNER SIGNAGE 08.28.2023 W. Ocotillo Rd S Dobson Rd Cornerstone Ranch W1 W2 W3 www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. W1 W2 Both Entry Wall Structures are Already Permitted and Installed Letters on this Wall Structure are Already Permitted and Installed www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. W1 W2 www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. W1 www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. 2’-0” 4” 8” 4” 3’-2” 5’-4” 1’-6” 1’-6” 21’-0” 3’-6” 3’-6” 7’-2” Scale: 3/8”=1’-0” 17’-8 1/2” New Letter Set for Existing Wall Structure LED Halo-Illuminated Reverse Pan Channel Letters Block Structure with Stucco Face LED Transformer 120 Volt Primary to 12 Volt Secondary Rear Wire Way Disconnect Switch Primary Power in 1/2” Flex Conduit J-Box with Power Provided by Customer Electrical Contractor .063” Aluminum Returns 2” Deep Clips to Secure Lexan Back .177” White Lexan Backs .090” Aluminum Face LED Lights 6” Studs with Nuts Spaced 1” Electrical Specifications X X X X X X U.L. Required Other Non U.L. Required 120 Volts 277 Volts Other ( ) 1 20 Amp Circuits Necessary 2.5A Actual Amp Load All Signs Fabricated as per 2014 N.E.C. Specifications All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code or Other Applicable Local Codes. Sign(s) to be manufactured to U.L. specifications and will bear the U.L. label(s). Install in accordance of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. Spalding Gray SW 6074 Light Texture Grizzle Gray SW 7068 Light Texture Perfect Greige SW 6073 Light Texture Adobe Integral Sand Finish Centurion-Bucks County Drystack Stone Cornerstone Ranch: 17.71 x 1.67 = 29.58 Sq. Ft. Luxury Rentals: 5.81 x .5 = 2.91 Sq. Ft. Total: 32.49 Sq. Ft. www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. 92 91 90 89 88 93 29' 2" 8" 7'-1" 21' 3' 3' 5' 27' 4" 2" 15' 9' 7'-3" 9'-8" 3' 18' 3'-6" 20'-4" 2' SIGN WALL W/ COLUMNS ALT. BID ITEM TRELLIS EX. SIDEWALK OCOTILLO RD. EX. SIDEWALK DOBSON RD. NEW PLANTING, TYP. REPLACE EX. SOD REPLACE EX. SOD REPLACE EX. SOD NEW PLANTING, TYP. NEW PLANTING, TYP. NEW PLANTING, TYP. 93 94 N CORNERSTONE RANCH DOBSON+OCOTILLLO CORNER SIGNAGE 08.28.2023 W. Ocotillo Rd S Dobson Rd Cornerstone Ranch W3 SECONDARY E.F. PERGOLA W3 1’-1” to Easement 18’-2” to Property Line 33’-9” to Curb PERGOLA 13’-9” to DOBSON Easement 22’-1” to DOBSON Property Line 35’-9” to DOBSON Curb 15’-8” to OCOTILLO Easement 32’-9” to OCOTILLO Property Line 48’-5” to OCOTILLO Curb SECONDARY E.F. 4’-10” to Easement 13’-4” to Property Line 27’-9“ to Curb www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. “Cornerstone Ranch”: 197.163” x 20.469”/144 = 28.03 Sq. Ft. “Luxury Rentals”: 69.855” x 6.458”/144 = 3.13 Sq. Ft. Total: 31.16 Sq. Ft. www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. “Cornerstone Ranch”: 197.163” x 20.469”/144 = 28.03 Sq. Ft. “Luxury Rentals”: 69.855” x 6.458”/144 = 3.13 Sq. Ft. Total: 31.16 Sq. Ft. LED Halo-Illuminated Reverse Pan Channel Letters Block Structure with Stucco Face LED Transformer 120 Volt Primary to 12 Volt Secondary Rear Wire Way Disconnect Switch Primary Power in 1/2” Flex Conduit J-Box with Power Provided by Customer Electrical Contractor .063” Aluminum Returns 2” Deep Clips to Secure Lexan Back .177” White Lexan Backs .090” Aluminum Face LED Lights 6” Studs with Nuts Spaced 1” Electrical Specifications X X X X X X U.L. Required Other Non U.L. Required 120 Volts 277 Volts Other ( ) 1 20 Amp Circuits Necessary 2.5A Actual Amp Load All Signs Fabricated as per 2014 N.E.C. Specifications All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code or Other Applicable Local Codes. Sign(s) to be manufactured to U.L. specifications and will bear the U.L. label(s). Install in accordance of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. Spalding Gray SW 6074 Light Texture Grizzle Gray SW 7068 Light Texture Perfect Greige SW 6073 Light Texture Adobe Integral Sand Finish Centurion-Bucks County Drystack Stone www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. Spalding Gray SW 6074 Light Texture Grizzle Gray SW 7068 Light Texture Perfect Greige SW 6073 Light Texture Adobe Integral Sand Finish Centurion-Bucks County Drystack Stone www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. Spalding Gray SW 6074 Light Texture Grizzle Gray SW 7068 Light Texture Perfect Greige SW 6073 Light Texture Adobe Integral Sand Finish www.bootzandduke.com 2831 W. Weldon Ave. | Phoenix, AZ 85017 (602) 272-9356 Date: Approved by: Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. This sign is intended to be installed in accordance with the requirements of Article 600 of the National Electrical Code. The location of the disconnect switch after installation shall comply with Article 600.6(A)(1) of the National Electrical Code. LISTED This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ. It may not be reproduced, copied, or exhibited in any fashion. 10'-10" 6" 6" 4" 4" 10" 2" 5" 6'-8" 4' 4" 2', TYP. CORNERSTONE RANCH LUXURY RENTALS 1'-8" 6" SIGN BLADE BASE CMU CAP MASONRY BASE WITH STONE VENEER METAL (3-D) LETTERS 8" 4' 1" 1'-8", TYP. MASONRY BASE WITH STUCCO FINISH (TO MATCH EX. PERGOLA @ SALES OFFICE) WOOD BEAMS TO MATCH MATERIAL & PAINT COLOR OF EXISTING PERGOLA BEAMS @ SALES OFFICE 3'-2", TYP. 3', TYP. 21' 3' TYP. 7'-1" 4" EXTEND VENEER 4" BELOW F.G. STONE VENEER TO BE: CENTURION, BUCKS COUNTY DRYSTACK STONE 4" COLUMN CORNICE WITH STUCCO FINISH (TO MATCH EX. PERGOLA @ SALES OFFICE) 92 91 90 89 88 93 93 94 OCOTILLO RD. EX. SIDEWALK DOBSON RD. 65' R/W 22'-10" 38'-4" 38'-11" 34'-5" 8' PUE 65' R/W 8' PUE 30' 30' Concrete Header - match ex. Trellis - see detail 1, this sheet Sign Columns - see detail 2, this sheet KEYNOTES Sign Walls - see detail 2, this sheet Ex. Concrete Header - protect in place or replace if damaged Concrete Paving - integral color Davis 'Adobe', sand (acid-etch) finish Planting Area - see L2 Site Visibility Triangle 8" 3' 9' 5'-1" 9'-8" 18' 3'-6" 20'-4" 2' 5' 3'-2" 3' 21' 2" 4" 2" 29' 26'-11" 15' 7'-1" t 480-991-3384 6115 N Cattletrack Rd Scottsdale AZ 85250 gbtwo.com CORNERSTONE RANCH 3999 S DOBSON RD CHANDLER, AZ 85248 DATE SHEET NUMBER SHEET TITLE 06/03/2024 06/03/24 0' 5' 10' 20' N HARDSCAPE KEYNOTE & LAYOUT PLAN - HARDSCAPE DETAILS L1 2 SIGN - ELEVATION SCALE 1/4" = 1'-0" 1 TRELLIS - ELEVATION SCALE 1/4" = 1'-0" NARRATIVE: Goal: To create an updated corner monument for Cornerstone Ranch in keeping with recent property upgrades. · Replace aged water feature signage that blocks corner off from the neighborhood · Provide a destination for apartment residents when walking pets · Upgrade the planting while maintaining mature existing trees · Repeat architectural details from the sales center Proposed trellis structure encroaches into Dobson Road and Ocotillo Road 50-foot setback - we are asking for approval on this deviation since we are enhancing the corner through landscaping, pedestrian features and signage. 3 LAYOUT PLAN SCALE 3/16" = 1'-0" PLANT LEGEND TREES BOTANICAL NAME COMMON NAME SIZE QTY. SHRUBS/GROUNDCOVERS Existing Tree to Remain White Iceberg Shrub Rose 5 Gal 9 Rosa spp. 'Iceberg Low-break multi Eremophila hygrophana Blue Bells™ Blue Bells Eremophila 5 Gal 23 Olneya tesota Desert Ironwood 48" Box 1 W Wedelia trilobata (syn. Sphalgneticola) Yellow Dot 5 Gal 64 ACCENTS New Turf (Midiron Sod) Decomposed granite, match color and size of pool project - 2" deep (all new planting areas) OTHER Irrigation: Adjust existing irrigation to ensure full coverage to all new plant materials and turf extents Lantana montevidensis 'New Gold' New Gold Lantana 5 Gal 27 Agave angustifolia 'Marginata' Caribbean Agave 5 Gal 7 Pachycereus schottii Senita 24" Box 2 Muhlenbergia capillaris 'Regal Mist' Regal Mist Pink Muhly Grass 5 Gal 37 3,200 sq. ft 6,095 sq. ft DIMENSIONS APPROX. TONNAGE BOULDER 4' X 3' X 3' 2 TONS C 9 QUANTITY 92 91 90 89 88 93 93 94 C C C C C C C W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W C C W W W W W W W W W W W W W OCOTILLO RD. EX. SIDEWALK DOBSON RD. 65' R/W 8' PUE 65' R/W 8' PUE USE BOULDERS TO RETAIN GRADE AS NEEDED TO PROTECT EX. PALM TO REMAIN BOULDER RETAINING WALL CONCRETE SIDEWALK 4" MIN. 6" EX. GRADE SURFACE SELECT GRANITE BOULDERS SET BOULDERS APPROXIMATELY 1 3 INTO EARTH TO RESEMBLE NATURAL FORMATION 2" DECOMPOSED GRANITE MULCH FINISH GRADE t 480-991-3384 6115 N Cattletrack Rd Scottsdale AZ 85250 gbtwo.com CORNERSTONE RANCH 3999 S DOBSON RD CHANDLER, AZ 85248 DATE SHEET NUMBER SHEET TITLE 06/03/2024 06/03/24 0' 5' 10' 20' N PLANTING PLAN L2 1 BOULDER RETAINING WALL SCALE 1/2" = 1'-0" 2 LANDSCAPE BOULDER INSTALLATION SCALE 1/2" = 1'-0" 1/2" MAX. PAVED SURFACE 2" FINISH GRADE DECOMPOSED GRANITE PRE-EMERGENT, SEE SPECS SOIL GRADE NOTES 1. PLANT IN SAME ORIENTATION AS ORIGINALLY GROWN. 2. BARE ROOTS SHALL NOT BE OUT OF THE GROUND FOR MORE THAN FIVE DAYS BEFORE PLANTING. 3. ROOT PRUNE ALL SHREDDED OR DAMAGED ROOTS. ENSURE ALL WOUNDS TO THE ROOT SYSTEM ARE CLEAN CUT. FINISH GRADE SOIL GRADE - PROVIDE POSITIVE DRAINAGE AWAY FROM BASE OF PLANT (DO NOT BURY IN GRANITE) MULCH PER SPECS BACKFILL WITH NATIVE SOIL AND AMENDMENTS PER SOIL REQUIREMENTS AND/OR SPECS. WATER AND TAMP TO SETTLE SOIL AND REMOVE AIR POCKETS. SCARIFY SIDES OF PLANTING HOLE TO PREVENT GLAZING EXISTING SUBSOIL INTACT ROOT STRUCTURE PLANT AT SAME DEPTH AS ORIGINALLY GROWN NOTES: 1. SCORE THE ROOTBALL; MAKE FOUR EQUALLY SPACED VERTICAL CUTS 1/4 TO 1/2 THE HEIGHT OF THE ROOTBALL, AND TWO ACROSS THE BOTTOM. 2. POSITION PLANT FOR "BEST SIDE" VIEW AND ORIENT SUNBURN SUSCEPTIBLE PLANTS PER ORIGINAL ROTATION. 3. TOP OF ROOTBALL SHALL BE FLUSH WITH OR UP TO 1" ABOVE FINISH GRADE. DEPTH OF ROOTBALL ROOTBALL 3X ROOTBALL FINISH GRADE SOIL GRADE MULCH BACKFILL WITH NATIVE SOIL AND AMENDMENTS PER SOIL REQUIREMENTS AND/OR SPECS. WATER AND TAMP TO SETTLE SOIL AND REMOVE AIR POCKETS. CONTROL RELEASE FERTILIZER TABS PLACED 6" BELOW FINISH GRADE SCARIFY SIDES OF PLANTING HOLE TO PREVENT GLAZING REMOVE BURLAP AROUND SHRUB BASE BEFORE PLANTING - IF ANY COMPACT SUBSOIL TO PREVENT SETTLING DEPTH OF ROOTBALL ROOTBALL 3X ROOTBALL FORM SAUCER ON LOWER SIDE OF SLOPE TO RETAIN WATER COMPACT SUBSOIL TO FORM PEDESTAL TO PREVENT SETTLING TREE TIES D.G. SOIL GRADE FINISH GRADE BACKFILL FERTILIZER IF STEEPNESS OF SLOPE CONSTRICTS SPECIFIED PLANT PIT SIZE, VERIFY SIZE WITH OWNER'S REPRESENTATIVE NOTE: SEE TYPICAL TREE PLANTING AND STAKING DETAIL FOR ADDITIONAL REQUIREMENTS. NOTES: 1. USE STAKING ONLY IF TREE IS UNSTABLE - SALVAGED TREES WILL NOT REQUIRE STAKING. VERIFY ALL OTHERS WITH OWNER'S REPRESENTATIVE. 2. SCORE THE ROOTBALL; MAKE FOUR VERTICAL CUTS 1/4 TO 1/2 THE HEIGHT OF THE ROOTBALL, ONE AT EACH SIDE, AND TWO ACROSS THE BOTTOM. 3. TOP OF ROOTBALL SHALL BE FLUSH WITH OR UP TO 1" ABOVE SOIL GRADE. 4. POSITION PLANT FOR "BEST SIDE" VIEW AND ORIENT SUNBURN SUSCEPTIBLE PLANTS PER ORIGINAL ROTATION. 5. ARRANGE THE STAKES AROUND TREE CANOPY TO PREVENT ABRASION WOUNDS TO BRANCHES. 6. INSTALL TREE GUARD ON ALL TREES LOCATED IN TURF - SEE SPECS OR PLANTING NOTES. DEPTH OF ROOTBALL 1/2% SLOPE AWAY TYP. ROOTBALL 3X ROOTBALL TREE TRUNKS (TYP.) TREE TIES - SEE ABOVE PLANT ROOTBALL LODGEPOLE STAKE, LOCATE OUTSIDE OF PLANT ROOTBALL, TYP. (2 STAKES MIN. PER SINGLE TRUNK, 3 STAKES MIN. PER MULTI-TRUNK, ADD STAKES AS NECESSARY TO PROPERLY SUPPORT TREE) TIE WIRES - SEE ABOVE TREE TIES: INSTALL ABOVE FIRST BRANCHES AND AS NECESSARY FOR FIRM SUPPORT (TYP.) MULCH PER SPECS OR PLANTING NOTES SOIL GRADE FINISH GRADE BACKFILL WITH NATIVE SOIL AND AMENDMENTS PER SOIL REQUIREMENTS AND/OR SPECS. WATER AND TAMP TO SETTLE SOIL AND REMOVE AIR POCKETS. CONTROL-RELEASE FERTILIZER TABS PLACED 6" BELOW FINISH GRADE DRIVE STAKE INTO SOLID SOIL 12" MINIMUM PAST BOTTOM OF PLANTING HOLE BREAK UP AND LOOSEN SOIL 1/2 THE DEPTH AND FIVE TIMES THE WIDTH OF THE ROOTBALL (NOT REQUIRED FOR HARDPAN OR SLOPE PLANTING CONDITION) SCARIFY SIDES OF PLATING HOLE TO PREVENT GLAZING COMPACT SUBSOIL TO PREVENT TREE FROM SETTLING REMOVE BURLAP AROUND TREE BASE BEFORE PLANTING - IF ANY TREE TIES (1 PER STAKE): 2-STRAND TWISTED 12 GA. GALV. WIRE ENCASED IN 1" DIA. 2-PLY RUBBER GARDEN HOSE PLANT ROOTBALL TIE WIRE TO INSIDE OF STAKES, GROOVE STAKE OR STAPLE WIRE TO STAKE. CRIMP ENDS OF WIRE TO PREVENT INJURY. 2" CLEAR TYP. SINGLE TRUNK STAKING MULTI-TRUNK STAKING NOTE: ONE TEST TREE PIT IS TO BE DUG WITHIN THE FIRST 30 DAYS OF THE PROJECT. COORDINATE TEST PIT LOCATION WITH OWNER'S REPRESENTATIVE. WATER TEST PIT TO VERIFY DRAINAGE CONDITIONS. CONTACT OWNER'S REPRESENTATIVE AFTER WATER TESTING TO COORDINATE EXTENT OF HARDPAN CONDITION AND WHERE HARDPAN PLANTING PROCEDURES SHALL BE REQUIRED. SEE HARDPAN TREE PLANTING DETAIL. 2" CLEAR TYP. PREVAILING WIND DIRECTION t 480-991-3384 6115 N Cattletrack Rd Scottsdale AZ 85250 gbtwo.com CORNERSTONE RANCH 3999 S DOBSON RD CHANDLER, AZ 85248 DATE SHEET NUMBER SHEET TITLE 06/03/2024 06/03/24 PLANTING DETAILS L3 1 TREE PLANTING AND STAKING SCALE = NTS 2 TREE PLANTING ON SLOPE SCALE = NTS 3 SHRUB PLANTING SCALE = NTS 4 ACCENT PLANTING SCALE = NTS 5 ROCK MULCH INSTALLATION SCALE 3" = 1'-0"