Comprehensive Sign Program

City of Chandler — Study Session (2024-10-14)

View PDF Meeting page

Extracted text (via pymupdf) 19628 characters
PLH22-0024 Cornerstone Ranch 
Comprehensive Sign Program

N
N
CORNERSTONE RANCH
DOBSON+OCOTILLLO CORNER SIGNAGE
08.28.2023
W. Ocotillo Rd
S Dobson Rd
Cornerstone Ranch
W1
W2
W3
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

W1
W2
Both Entry Wall Structures are
Already Permitted and Installed
Letters on this Wall Structure are
Already Permitted and Installed
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

W1
W2
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

W1
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

2’-0”
4”
8”
4”
3’-2”
5’-4”
1’-6”
1’-6”
21’-0”
3’-6”
3’-6”
7’-2”
Scale: 3/8”=1’-0”
17’-8 1/2”
New Letter Set for Existing Wall Structure
LED Halo-Illuminated Reverse Pan Channel Letters 
Block Structure
with Stucco Face
LED Transformer
120 Volt Primary to 
12 Volt Secondary
Rear Wire Way
Disconnect Switch
Primary Power in
1/2” Flex Conduit 
J-Box with Power Provided by
Customer Electrical Contractor
.063” Aluminum Returns 2” Deep
Clips to Secure Lexan Back
.177” White Lexan Backs
.090” Aluminum Face
LED Lights
6” Studs with Nuts Spaced 1”
Electrical Specifications
X
X
X
X
X
X
U.L. Required         Other                         Non U.L. Required 
120 Volts                277 Volts                    Other 
(  )
1
20 Amp Circuits Necessary
2.5A            
Actual Amp Load 
All Signs Fabricated as per 2014 N.E.C. Specifications
All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. 
This sign is intended to be installed in accordance with the requirements of
Article 600 of the National Electrical Code or Other Applicable Local Codes.
Sign(s) to be manufactured to U.L. specifications and will bear the U.L.
label(s). Install in accordance of the National Electrical Code.
The location of the disconnect switch after installation shall comply with
Article 600.6(A)(1) of the National Electrical Code.
Spalding Gray SW 6074 Light Texture 
Grizzle Gray SW 7068 Light Texture
Perfect Greige SW 6073 Light Texture
Adobe Integral Sand Finish
Centurion-Bucks County Drystack Stone
Cornerstone Ranch: 17.71 x 1.67 = 29.58 Sq. Ft.
Luxury Rentals: 5.81 x .5 = 2.91 Sq. Ft.  
Total: 32.49 Sq. Ft.
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

92
91
90
89
88
93
29'
2"
8"
7'-1"
21'
3'
3'
5'
27'
4"
2"
15'
9'
7'-3"
9'-8"
3'
18'
3'-6"
20'-4"
2'
SIGN WALL W/ COLUMNS
ALT. BID ITEM TRELLIS
EX. SIDEWALK
OCOTILLO RD.
EX. SIDEWALK
DOBSON RD.
NEW PLANTING, TYP.
REPLACE EX. SOD
REPLACE EX. SOD
REPLACE EX. SOD
NEW PLANTING, TYP.
NEW PLANTING, TYP.
NEW PLANTING, TYP.
93
94
N
CORNERSTONE RANCH
DOBSON+OCOTILLLO CORNER SIGNAGE
08.28.2023
W. Ocotillo Rd
S Dobson Rd
Cornerstone Ranch
W3
SECONDARY E.F.
PERGOLA
W3
1’-1” to Easement
18’-2” to Property Line
33’-9” to Curb
PERGOLA
13’-9” to DOBSON Easement
22’-1” to DOBSON Property Line
35’-9” to DOBSON Curb
15’-8” to OCOTILLO Easement
32’-9” to OCOTILLO Property Line
48’-5” to OCOTILLO Curb
SECONDARY E.F.
4’-10” to Easement
13’-4” to Property Line
27’-9“ to Curb
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

“Cornerstone Ranch”: 197.163” x 20.469”/144 = 28.03 Sq. Ft.
“Luxury Rentals”: 69.855” x 6.458”/144 = 3.13 Sq. Ft.  
Total: 31.16 Sq. Ft.
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

“Cornerstone Ranch”: 197.163” x 20.469”/144 = 28.03 Sq. Ft.
“Luxury Rentals”: 69.855” x 6.458”/144 = 3.13 Sq. Ft.  
Total: 31.16 Sq. Ft.
LED Halo-Illuminated Reverse Pan Channel Letters 
Block Structure
with Stucco Face
LED Transformer
120 Volt Primary to 
12 Volt Secondary
Rear Wire Way
Disconnect Switch
Primary Power in
1/2” Flex Conduit 
J-Box with Power Provided by
Customer Electrical Contractor
.063” Aluminum Returns 2” Deep
Clips to Secure Lexan Back
.177” White Lexan Backs
.090” Aluminum Face
LED Lights
6” Studs with Nuts Spaced 1”
Electrical Specifications
X
X
X
X
X
X
U.L. Required         Other                         Non U.L. Required 
120 Volts                277 Volts                    Other 
(  )
1
20 Amp Circuits Necessary
2.5A            
Actual Amp Load 
All Signs Fabricated as per 2014 N.E.C. Specifications
All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C. 
This sign is intended to be installed in accordance with the requirements of
Article 600 of the National Electrical Code or Other Applicable Local Codes.
Sign(s) to be manufactured to U.L. specifications and will bear the U.L.
label(s). Install in accordance of the National Electrical Code.
The location of the disconnect switch after installation shall comply with
Article 600.6(A)(1) of the National Electrical Code.
Spalding Gray SW 6074 Light Texture 
Grizzle Gray SW 7068 Light Texture
Perfect Greige SW 6073 Light Texture
Adobe Integral Sand Finish
Centurion-Bucks County Drystack Stone
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

Spalding Gray SW 6074 Light Texture 
Grizzle Gray SW 7068 Light Texture
Perfect Greige SW 6073 Light Texture
Adobe Integral Sand Finish
Centurion-Bucks County Drystack Stone
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

Spalding Gray SW 6074 Light Texture 
Grizzle Gray SW 7068 Light Texture
Perfect Greige SW 6073 Light Texture
Adobe Integral Sand Finish
www.bootzandduke.com
2831 W. Weldon Ave. | Phoenix, AZ  85017
(602) 272-9356
Date:
Approved by:
Electrical Specifications: All Signs Fabricated as per 2017 N.E.C. Specifications
Engineering Specifications: All Signs Fabricated per A.S.A. Specifications & 2018 I.B.C.
This sign is intended to be installed in accordance with the
requirements of Article 600 of the National Electrical Code.
The location of the disconnect switch after installation shall
comply with Article 600.6(A)(1) of the National Electrical Code.
LISTED
This custom design is the exclusive property of Bootz & Duke Sign Co. of Phx, AZ.
It may not be reproduced, copied, or exhibited in any fashion.

10'-10"
6"
6"
4"
4"
10"
2"
5"
6'-8"
4'
4"
2', TYP.
CORNERSTONE RANCH
LUXURY RENTALS
1'-8"
6"
SIGN BLADE BASE
CMU CAP
MASONRY BASE
WITH STONE
VENEER
METAL (3-D) LETTERS
8"
4'
1"
1'-8", TYP.
MASONRY BASE WITH
STUCCO FINISH (TO
MATCH EX. PERGOLA
@ SALES OFFICE)
WOOD BEAMS TO MATCH
MATERIAL & PAINT COLOR
OF EXISTING PERGOLA
BEAMS @ SALES OFFICE
3'-2", TYP.
3', TYP.
21'
3' TYP.
7'-1"
4"
EXTEND VENEER 4"
BELOW F.G.
STONE VENEER TO BE: CENTURION,
BUCKS COUNTY DRYSTACK STONE
4"
COLUMN CORNICE
WITH STUCCO FINISH
(TO MATCH EX.
PERGOLA @ SALES
OFFICE)
92
91
90
89
88
93
93
94
OCOTILLO RD.
EX. SIDEWALK
DOBSON RD.
65' R/W
22'-10"
38'-4"
38'-11"
34'-5"
8'
PUE
65' R/W
8' PUE
30'
30'
Concrete Header - match ex.
Trellis - see detail 1, this sheet
Sign Columns - see detail 2, this sheet
KEYNOTES
Sign Walls - see detail 2, this sheet
Ex. Concrete Header - protect in place or replace if damaged
Concrete Paving - integral color Davis 'Adobe', sand (acid-etch) finish
Planting Area - see L2
Site Visibility Triangle
8"
3'
9'
5'-1"
9'-8"
18'
3'-6"
20'-4"
2'
5'
3'-2"
3'
21'
2"
4"
2"
29'
26'-11"
15'
7'-1"
t 480-991-3384                      
6115 N Cattletrack Rd  Scottsdale AZ 85250
gbtwo.com
CORNERSTONE RANCH
3999 S DOBSON RD
CHANDLER, AZ 85248
DATE
SHEET NUMBER
SHEET TITLE
06/03/2024
06/03/24
0'
5'
10'
20'
N
HARDSCAPE
KEYNOTE &
LAYOUT PLAN
- HARDSCAPE
DETAILS
L1
2
SIGN - ELEVATION
SCALE 1/4" = 1'-0"
1
TRELLIS - ELEVATION
SCALE 1/4" = 1'-0"
NARRATIVE:
Goal: To create an updated corner monument for Cornerstone Ranch in keeping
with recent property upgrades.
·
Replace aged water feature signage that blocks corner off from the
neighborhood
·
Provide a destination for apartment residents when walking pets
·
Upgrade the planting while maintaining mature existing trees
·
Repeat architectural details from the sales center
Proposed trellis structure encroaches into Dobson Road and Ocotillo Road 50-foot
setback - we are asking for approval on this deviation since we are enhancing the
corner through landscaping, pedestrian features and signage.
3
LAYOUT PLAN
SCALE 3/16" = 1'-0"

PLANT LEGEND
TREES
BOTANICAL NAME
COMMON NAME
SIZE
QTY.
SHRUBS/GROUNDCOVERS
Existing Tree to Remain
White Iceberg Shrub Rose
5 Gal
9
Rosa spp. 'Iceberg
Low-break multi
Eremophila hygrophana Blue Bells™
Blue Bells Eremophila 
5 Gal
23
Olneya tesota
Desert Ironwood
48" Box
1
W
Wedelia trilobata (syn. Sphalgneticola)
Yellow Dot
5 Gal
64
ACCENTS
New Turf (Midiron Sod)
Decomposed granite, match color and size of
pool project - 2" deep  (all new planting areas)
OTHER
Irrigation: Adjust existing irrigation to ensure full coverage to all
new plant materials and turf extents
Lantana montevidensis 'New Gold'
New Gold Lantana
5 Gal
27
Agave angustifolia 'Marginata'
Caribbean Agave
5 Gal
7
Pachycereus schottii
Senita
24" Box
2
Muhlenbergia capillaris 'Regal Mist'
Regal Mist Pink Muhly Grass
5 Gal
37
3,200 sq. ft
6,095 sq. ft
DIMENSIONS
APPROX. TONNAGE
BOULDER
4' X 3' X 3'
2 TONS
C
9
QUANTITY
92
91
90
89
88
93
93
94
C
C
C
C
C
C
C
W
W W
W
W
W
W
W
W
W
W
W
W
W
W
W
W W
W
W
W
W
W
W
W
W
W W
W
W
W W
W
W
W W
W W
W W
W
W
W
W W
W
W
W
W
W
C
C
W
W
W
W
W
W
W
W
W
W
W
W
W
OCOTILLO RD.
EX. SIDEWALK
DOBSON RD.
65' R/W
8'
PUE
65' R/W
8' PUE
USE BOULDERS TO RETAIN
GRADE AS NEEDED TO
PROTECT EX. PALM TO REMAIN
BOULDER
RETAINING WALL
CONCRETE
SIDEWALK
4" MIN.
6"
EX. GRADE
SURFACE SELECT GRANITE
BOULDERS
SET BOULDERS APPROXIMATELY
1
3 INTO EARTH TO RESEMBLE
NATURAL FORMATION
2" DECOMPOSED
GRANITE MULCH
FINISH GRADE
t 480-991-3384                      
6115 N Cattletrack Rd  Scottsdale AZ 85250
gbtwo.com
CORNERSTONE RANCH
3999 S DOBSON RD
CHANDLER, AZ 85248
DATE
SHEET NUMBER
SHEET TITLE
06/03/2024
06/03/24
0'
5'
10'
20'
N
PLANTING
PLAN
L2
1
BOULDER RETAINING WALL
SCALE 1/2" = 1'-0"
2
LANDSCAPE BOULDER INSTALLATION
SCALE 1/2" = 1'-0"

1/2" MAX.
PAVED
SURFACE
2"
FINISH GRADE
DECOMPOSED GRANITE
PRE-EMERGENT,
SEE SPECS
SOIL GRADE
NOTES
1.  PLANT IN SAME ORIENTATION AS ORIGINALLY GROWN.
2.  BARE ROOTS SHALL NOT BE OUT OF THE GROUND FOR MORE THAN FIVE DAYS BEFORE PLANTING.
3.  ROOT PRUNE ALL SHREDDED OR DAMAGED ROOTS.  ENSURE ALL WOUNDS TO THE ROOT SYSTEM ARE CLEAN CUT.
FINISH GRADE
SOIL GRADE - PROVIDE POSITIVE
DRAINAGE AWAY FROM BASE OF
PLANT (DO NOT BURY IN GRANITE)
MULCH PER SPECS
BACKFILL WITH NATIVE SOIL AND
AMENDMENTS PER SOIL REQUIREMENTS
AND/OR SPECS.  WATER AND TAMP TO
SETTLE SOIL AND REMOVE AIR POCKETS.
SCARIFY SIDES OF PLANTING
HOLE TO PREVENT GLAZING
EXISTING SUBSOIL
INTACT ROOT STRUCTURE
PLANT AT SAME DEPTH AS
ORIGINALLY GROWN
NOTES:
1.  SCORE THE ROOTBALL; MAKE FOUR EQUALLY SPACED VERTICAL CUTS 1/4 TO 1/2 THE HEIGHT OF THE ROOTBALL, AND
TWO ACROSS THE BOTTOM.
2.  POSITION PLANT FOR "BEST SIDE" VIEW AND ORIENT SUNBURN SUSCEPTIBLE PLANTS PER ORIGINAL ROTATION.
3. TOP OF ROOTBALL SHALL BE FLUSH WITH OR UP TO 1" ABOVE FINISH GRADE.
DEPTH OF
ROOTBALL
ROOTBALL
3X ROOTBALL
FINISH GRADE
SOIL GRADE
MULCH
BACKFILL WITH NATIVE
SOIL AND AMENDMENTS
PER SOIL REQUIREMENTS
AND/OR SPECS.  WATER
AND TAMP TO SETTLE SOIL
AND REMOVE AIR
POCKETS.
CONTROL RELEASE
FERTILIZER TABS PLACED
6" BELOW FINISH GRADE
SCARIFY SIDES OF PLANTING
HOLE TO PREVENT GLAZING
REMOVE BURLAP AROUND
SHRUB BASE BEFORE
PLANTING - IF ANY
COMPACT SUBSOIL TO
PREVENT SETTLING
DEPTH OF ROOTBALL
ROOTBALL
3X ROOTBALL
FORM SAUCER ON
LOWER SIDE OF SLOPE
TO RETAIN WATER
COMPACT SUBSOIL TO FORM
PEDESTAL TO PREVENT
SETTLING
TREE TIES
D.G.
SOIL GRADE
FINISH GRADE
BACKFILL
FERTILIZER
IF STEEPNESS OF SLOPE
CONSTRICTS SPECIFIED
PLANT PIT SIZE, VERIFY SIZE
WITH OWNER'S
REPRESENTATIVE
NOTE:
SEE TYPICAL TREE PLANTING AND STAKING DETAIL FOR ADDITIONAL REQUIREMENTS.
NOTES:
1.  USE STAKING ONLY IF TREE IS UNSTABLE - SALVAGED TREES WILL NOT REQUIRE STAKING.
VERIFY ALL OTHERS WITH OWNER'S REPRESENTATIVE.
2.  SCORE THE ROOTBALL; MAKE FOUR VERTICAL CUTS 1/4 TO 1/2 THE HEIGHT OF THE ROOTBALL,
ONE AT EACH SIDE, AND TWO ACROSS THE BOTTOM.
3.  TOP OF ROOTBALL SHALL BE FLUSH WITH OR UP TO 1" ABOVE SOIL GRADE.
4.  POSITION PLANT FOR "BEST SIDE" VIEW AND ORIENT SUNBURN SUSCEPTIBLE PLANTS PER
ORIGINAL ROTATION.
5.  ARRANGE THE STAKES AROUND TREE CANOPY TO PREVENT ABRASION WOUNDS TO
BRANCHES.
6.  INSTALL TREE GUARD ON ALL TREES LOCATED IN TURF - SEE SPECS OR PLANTING NOTES.
DEPTH OF ROOTBALL
 1/2% SLOPE
AWAY TYP.
ROOTBALL
3X ROOTBALL
TREE TRUNKS (TYP.)
TREE TIES - SEE ABOVE
PLANT ROOTBALL
LODGEPOLE STAKE, LOCATE OUTSIDE
OF PLANT ROOTBALL, TYP. (2 STAKES
MIN. PER SINGLE TRUNK, 3 STAKES
MIN. PER MULTI-TRUNK, ADD STAKES
AS NECESSARY TO PROPERLY
SUPPORT TREE)
TIE WIRES - SEE ABOVE
TREE TIES: INSTALL ABOVE FIRST
BRANCHES AND AS NECESSARY FOR FIRM
SUPPORT (TYP.)
MULCH PER SPECS OR
PLANTING NOTES
SOIL GRADE
FINISH GRADE
BACKFILL WITH NATIVE SOIL AND
AMENDMENTS PER SOIL REQUIREMENTS
AND/OR SPECS.  WATER AND TAMP TO
SETTLE SOIL AND REMOVE AIR POCKETS.
CONTROL-RELEASE FERTILIZER TABS
PLACED 6" BELOW FINISH GRADE
DRIVE STAKE INTO SOLID SOIL 12"
MINIMUM PAST BOTTOM OF
PLANTING HOLE
BREAK UP AND LOOSEN
SOIL 1/2 THE DEPTH AND
FIVE TIMES THE WIDTH OF
THE ROOTBALL
(NOT REQUIRED FOR
HARDPAN OR SLOPE
PLANTING CONDITION)
SCARIFY SIDES OF PLATING
HOLE TO PREVENT GLAZING
COMPACT SUBSOIL TO
PREVENT TREE FROM
SETTLING
REMOVE BURLAP
AROUND TREE BASE
BEFORE PLANTING -
IF ANY
TREE TIES (1 PER STAKE):
2-STRAND TWISTED 12 GA.
GALV. WIRE ENCASED IN 1"
DIA. 2-PLY RUBBER GARDEN
HOSE
PLANT ROOTBALL
TIE WIRE TO INSIDE OF STAKES,
GROOVE STAKE OR STAPLE WIRE TO
STAKE.  CRIMP ENDS OF WIRE TO
PREVENT INJURY.
2" CLEAR
TYP.
SINGLE TRUNK STAKING
MULTI-TRUNK STAKING
NOTE:
ONE TEST TREE PIT IS TO BE DUG WITHIN THE FIRST 30 DAYS OF THE PROJECT.  COORDINATE TEST PIT
LOCATION WITH OWNER'S REPRESENTATIVE. WATER TEST PIT TO VERIFY DRAINAGE CONDITIONS. CONTACT
OWNER'S REPRESENTATIVE AFTER WATER TESTING TO COORDINATE EXTENT OF HARDPAN CONDITION AND
WHERE HARDPAN PLANTING PROCEDURES SHALL BE REQUIRED. SEE HARDPAN TREE PLANTING DETAIL.
2"
CLEAR
TYP.
PREVAILING
WIND
DIRECTION
t 480-991-3384                      
6115 N Cattletrack Rd  Scottsdale AZ 85250
gbtwo.com
CORNERSTONE RANCH
3999 S DOBSON RD
CHANDLER, AZ 85248
DATE
SHEET NUMBER
SHEET TITLE
06/03/2024
06/03/24
PLANTING
DETAILS
L3
1
TREE PLANTING AND STAKING
SCALE = NTS
2
TREE PLANTING ON SLOPE
SCALE = NTS
3
SHRUB PLANTING 
SCALE = NTS
4
ACCENT PLANTING 
SCALE = NTS
5
ROCK MULCH INSTALLATION
SCALE 3" = 1'-0"