2024 Construction Code Highlights

City of Chandler — Regular Meeting (2024-11-07)

View PDF Meeting page

Extracted text (via pymupdf) 18236 characters
Local Amendments:
Notes:
Subsection 104.2.3 "Alternative materials, design and methods of construction and equipment" 
is hereby amended by deleting the entire exception to this subsection.
The International Code Council 
Performance Code is not adopted in 
the City of Chandler.
Subsection 111.1 "Change of occupancy", Subsection 111.2 "Certificate Issued" and Subsection 
111.3 "Temporary occupancy". The city has no proposed amendment to these subsections. 
When the new code is adopted then it will go into the City Code as written.
Ensure the essential safety features 
such as required fire sprinkler 
systems and design occupant load on 
the issued certificate of occupancy to 
meet the building and fire safety 
standards accurately and consistently.
Subsection 412.4.5 "Height and area limits" is hereby amended by deleting the entire paragraph 
and reword it along with an additional note “d” to TABLE 412.3.6 as follows: Residential aircraft 
hangars shall be provided with a group 13R fire suppression system OR the hangar and dwelling 
may be provided with a group 13D fire suppression system.
For the sake of consistence, Chandler 
would provide a clear guidance for all 
residential aircraft hangars to comply 
with the fire suppression 
requirements, instead of case-by-case 
basis.
Subsection 1612.3 "Establishment of flood hazard areas" is hereby amended by inserting The 
City of Chandler, Arizona as Name of Jurisdiction and the latest effective date as Date of 
Issuance.
Provide specific information about 
name of jurisdiction and date of 
issuance.
Model Code Changes:
Notes:
Chapter 9 has added many sections for fire protection requirements associated with lithium-ion 
battery manufacturing, storage, use, repair, charging and research.
Provides more fire protection 
requirements for the ever-growing 
lithium-ion battery applications.
SECTION 907.10.1 – SMOKE ALARM REPLACEMENT was added requiring the replacement of 
smoke detectors.
Specify smoke alarm replacement in 
certain situations.
2024 Construction Codes Adoption Highlights
International 
Building Code
Page 1 of 10

SECTIONS 912.5.1 – 912.5.4 - SIGNS were added dictating signage for sprinkler system fire 
department connections on multiple buildings or with combined systems.
FDC signage in Chandler is dictated by 
Fire Department detail FD104 and 
requires 2” letters.
SECTION 915 – CARBON MONOXIDE DETECTION is now applied in any occupancy with a CO 
source requires detection and/or alarm. CO detectors are required to be tied into the fire alarm 
and activate notification alarm.
Provides CO detection in many more 
occupancies with a CO source.
SECTION 917.2 – MASS NOTIFICATION was added into all Group E occupancies in addition to 
college and university campuses that were previously in this section.
Currently only applied in college and 
university campuses. Not, it applies 
for all Group E occupancies.
Local Amendments:
Notes:
Subsection 110.3 "Examination, Identification, Installation, Use, and Listing (Product 
Certification) of Equipment" is hereby amended by adding language "or other agencies 
approved by the City of Chandler building official" into body of code to simplify the listing 
requirement.
Chandler allows for equipment 
evaluation to be done by a wider 
range of qualified personnel including 
nationally recognized testing labs, 
qualified engineers, and sometimes 
by qualified staff. 
Subsection 210.8 "Ground-Fault Circuit-Interrupter Protection for Personnel" is hereby 
amended by adding an exception at the end of 210.8(A)(3) as follows. Exception: Plug 
receptacles that are designed to be used for powering listed air conditioning, heating or cooling 
equipment.
Protect Chandler residents from 
suffering heat related health injuries 
due to HVAC shut down since the 
variable speed motors used to gain 
higher efficiencies in HVAC would 
almost certainly trip the GFCI 
breakers.
Subsection 210.8 (F) "Outdoor Outlets" is amended by deleting its expiration date from the 
exception to read as follows. Exception No. 2: GFCI protection shall not be required for listed 
HVAC equipment.
The variable speed motors would 
likely trip the GFCI breakers and cause 
HVAC equipment shut-downs. 
National 
Electrical Code
Page 2 of 10

Subsection 230.67 “Surge Protection". The city has no proposed amendment to this subsection. 
When the new code is adopted then it will go into the City Code as written. 
The surge protection not only 
provides the protection for the 
equipment, but also prevents the 
potential fire hazards from happening 
as well. This is coordinated with the 
surge protection application as 
described in the International 
Residential Code.
Subsection 406.12 “Tamper-Resistant Receptacles” is amended by deleting its use in the item 10 
for areas of agricultural buildings.
Tamper-resistant receptacles are an 
important next step to make the 
home a safer place for children and 
are becoming the industry standard.
Model Code Changes:
Notes:
SECTION 210.8(A)(6) Dwelling Units now require all kitchen receptacles to have GFCI protection.
Additional GFCI locations are now 
required in kitchen area.
SECTION 210.8(D) – GFCI is required to be installed for drinking water cooler, electric ranges, 
wall mounted ovens, counter mounted cooking units and microwaves.
Adds GFCI protection to several more 
appliances both in single family and 
multi-family structures.
SECTION 210.23(A) – TEN-AMPERE BRANCH CIRCUIT was added to supply lighting outlets, 
exhaust fans or a gas fireplace.
Ten-ampere circuits are only applied 
for a limited applications.
SECTIONS 220.5(C) / 220.41 – LIGHTING LOADS FOR DWELLING UNITS was a new section. It now 
requires the floor area of garages to be included when calculating the minimum lighting load for 
dwelling units.
A garage is in a trend of becoming 
adaptable for future use as a 
habitable room or occupiable space.
Page 3 of 10

SECTION 225.41(A)(B)(C) – EMERGENCY DISCONNECTS requires that the marking must be on the 
outside of the front of the enclosure, must have red background with white text and lettering 
must at least ½” high.
First responders can easily identify 
the location of Emergency Disconnect 
installed at a readily accessible 
outdoor location on or within site of 
the dwelling unit.
SECTION 630.8 – GFCI PROTECTION FOR PERSONNEL now requires GFCI protection for all 125v, 
single-phase, 15 and 20-amp receptacles for hand tools or portable lighting equipment in areas 
where welders are operated.
Provide GFCI for safety protection.
Local Amendments:
Notes:
CHAPTER 1 "SCOPE AND ADMINISTRATION" is amended by deleting in its entirety to comply 
with the provisions along with the amendments as described in the CHAPTER 1 SCOPE AND 
ADMINISTRATION of the 2024 International Building Code.
Eliminate the duplication and 
redundancy, we update only one 
administration chapter in the IBC and 
apply it for the other related codes.
Model Code Changes:
Notes:
SECTION 419.6 – SOAP DISPENSERS shall be provided for public lavatories.
For the sake of public health.
SECTION 504.7 – Required Pan now allows a plastic pan installed beneath a gas-fired water 
heater and shall be constructed of material having a flame spread index of 25 or less and a 
smoked-developed index of 450 or less.
Currently not allow use of a plastic 
pan installed beneath a gas fired 
water heater.
Local Amendments:
Notes:
CHAPTER 1 "SCOPE AND ADMINISTRATION" is amended by deleting in its entirety to comply 
with the provisions along with the amendments as described in the CHAPTER 1 SCOPE AND 
ADMINISTRATION of the 2024 International Building Code.
Eliminate the duplication and 
redundancy, we update only one 
administration chapter in the IBC and 
apply it for the other related codes.
International 
Plumbing Code
International 
Mechanical Code
Page 4 of 10

Model Code Changes:
Notes:
SECTION 306.5 - Equipment or Appliances on Roofs or Elevated Structures now requires a top 
landing. The ladder shall be provided with a clear and unobstructed landing on the exit side of 
the roof hatch, having a minimum space of 30 inches deep and being the same width as the 
hatch.
Provide a safety measure for workers 
and inspectors working in the roof 
top.
Local Amendments:
Notes:
Subsection R102.2 "Other laws" is amended by adding the following provisions to the end 
thereof: Additionally, the building official will enforce the provisions of such other laws when 
mandated by state or federal law.
Align with the amendment to the 
International Building Code.
Subsection 103.1 "Creation of agency” is hereby amended by inserting Development Services 
Department as Name of Department.
Align with the amendment to the 
International Building Code.
Subsection R105.2 "Work exempt from permit" is amended by adding items 6 and 7 into the 
electrical items exempt from permit.
Add those missed electrical items 
exempt from permit back into the city 
code.
Subsection R110.1 "Use and change of occupancy", Subsection R110.2 "Certificate Issued" and 
Subsection R110.3 "Temporary occupancy". The city has no proposed amendment to these 
subsections. When the new code is adopted then it will go into the City Code as written.
Ensure the essential safety features 
such as required fire sprinkler 
systems and design occupant load on 
the issued certificate of occupancy to 
meet the building and fire safety 
standards accurately and consistently.
Subsection N1101.13 (R401.2) "Application" is amended by deleting this amendment from the 
city code.
Section N1101.13.5 has been deleted 
from the 2024 IRC Chapter 11.
International 
Residential Code
Page 5 of 10

Subsection N1101.13.5 (R401.2.5) "Additional energy efficiency" is amended by deleting this 
amendment from the city code.
Section N1101.13.5 has been deleted 
from the 2024 IRC Chapter 11. The 
additional energy efficiency 
requirements will increase additional 
costs that are far exceed the 
negligible energy savings.
TABLE N1102.1.3 (R402.1.3) “INSULATION MINIMUM R-VALUES AND FENESTRATION 
REQUIREMENTS BY COMPONENT” is hereby amended by deleting this amendment from the city 
code.
The ceiling R-value has been changed 
back from “49” to “38” in the 2024 IRC 
Chapter 11. The increase in ceiling R-
value does not contribute substantial 
energy savings, but it would add 
substantial costs to builders and 
homeowners.
Subsection N1103.3.7 (R403.3.7) "Duct system testing" is amended by adding one new exception 
to read as follows: 4. A duct air-leakage test shall not be required where the ducts and air 
handlers are located entirely within the building thermal envelop.
Align with the amendment to the 
International Energy Conservation 
Code. It could encourage more home 
builders to design homes with all 
ducts and air handlers within the 
thermal envelop.
Subsection N1110.2.5 (R502.2.5) "Additional efficiency credit requirements for additions" is 
amended by deleting the subsection in its entirety.
The additional energy efficiency 
requirements will increase additional 
costs that are far exceed the 
negligible energy savings. 
Page 6 of 10

Subsection N1111.1.5 (R503.1.5) "Additional efficiency credit requirements for substantial 
improvements" is amended by deleting the subsection in its entirety.
The additional energy efficiency 
requirements will increase additional 
costs that are far exceed the 
negligible energy savings.
Subsection E3902.3 "Outdoor receptacles" is hereby amended by adding an exception to read 
as follows. Exception: Plug receptacles that are designed to be used for powering listed air 
conditioning, heating or cooling equipment.
Protect Chandler residents from 
suffering heat related health injuries 
due to HVAC shut down since the 
variable speed motors used to gain 
higher efficiencies in HVAC would 
almost certainly trip the GFCI 
breakers.
Subsection E3902.14 "Outdoor outlets" is amended by deleting its expiration date from the 
exception to read as follows. Exception No. 2: GFCI protection shall not be required for listed 
HVAC equipment.
The variable speed motors would 
likely trip the GFCI breakers and cause 
HVAC equipment shut-downs. 
Model Code Changes:
Notes:
SECTION R315 – SLEEPING LOFTS was added addressing spaces designated for sleeping on an 
intermediate level or levels between the floor and ceiling of a story.  
Provide more allowance for sleeping 
spaces.
SECTION R330.8.1 – ESS VEHICLE IMPACT PROTECTION was added addressing the protection of 
Energy Storage Systems installed in garages. 
Provides a safety measure addressing 
location, construction, size and height 
of these barriers.
SECTION N1103.13/R403.13 – GAS FIREPLACES was added to remove the option for installation 
of a gas fireplace that utilizes a continuous pilot light. Gas fireplaces need to be the ones with 
electronic ignition.
Provide extra safety for home owners 
who have gas fireplaces.
Page 7 of 10

SECTION E3601.8 – EMERGENCY DISCONNECTS requires the marking must be on the outside of 
the front of the enclosure, must have red background with white text and lettering must at least 
½” high.
First responders can easily identify 
the location of Emergency Disconnect 
installed at a readily accessible 
outdoor location on or within site of 
the dwelling unit.
SECTION – E3702.3 – TEN-AMPERE BRANCH CIRCUIT was added to supply lighting outlets, 
exhaust fans or a gas fireplace.
This ten-ampere circuits only applies 
for a limited applications.
SECTION – E3706.2 – PANELBOARD CIRCUIT IDENTIFICATION was added requiring a directory 
that clearly explains abbreviations and symbols if abbreviations and symbols are used. 
Owners and techanicens can easily 
identify the specific use.
Local Amendments:
Notes:
CHAPTER 1 "SCOPE AND ADMINISTRATION" is amended by deleting in its entirety to comply 
with the provisions along with the amendments as described in the CHAPTER 1 SCOPE AND 
ADMINISTRATION of the 2024 International Building Code.
Eliminate the duplication and 
redundancy, we update only one 
administration chapter in the IBC and 
apply it for the other related codes.
Model Code Changes:
Notes:
No significant changes.
No significant changes.
Local Amendments:
Notes:
Subsection C102.2 "Other laws" is amended by adding the following provisions to the end 
thereof: Additionally, the building official will enforce the provisions of such other laws when 
mandated by state or federal law.
Align with the amendment to the 
International Building Code.
Subsection C104.1 "Creation of enforcement agency” is hereby amended by inserting 
Development Services Department as Name of Department.
Align with the amendment to the 
International Building Code.
International 
Fuel Gas Code
International 
Energy 
Conservation 
Code
Page 8 of 10

Subsection C405.15 "Renewable energy systems" is hereby to delete in its entirety.
The renewable energy systems will 
increase additional costs that are far 
exceed the negligible energy savings. 
Subsection R102.2 "Other laws" is amended by adding the following provisions to the end 
thereof: Additionally, the building official will enforce the provisions of such other laws when 
mandated by state or federal law.
Align with the amendment to the 
International Building Code.
Subsection R103.1 "Creation of enforcement agency” is hereby amended by inserting 
Development Services Department as Name of Department.
Align with the amendment to the 
International Building Code.
Subsection R401.2 "Application" is amended by deleting this amendment from the city code.
Section R401.2.5 has been deleted 
from the 2024 IECC.
Subsection R401.2.5 "Additional energy efficiency" is amended by deleting this amendment 
from the city code.
Subsection R401.2.5 has been deleted 
from the 2024 IECC. The additional 
energy efficiency requirements will 
increase additional costs that are far 
exceed the negligible energy savings. 
TABLE R402.1.3 “INSULATION MINIMUM R-VALUES AND FENESTRATION REQUIREMENTS BY 
COMPONENT” is hereby amended by deleting this amendment from the city code.
The ceiling R-value has been changed 
back from “49” to “38” in the 2024 
IECC. The increase in ceiling R-value 
does not contribute substantial 
energy savings, but it would add 
substantial costs to builders and 
homeowners.
Page 9 of 10

Subsection R502.2.5 "Additional efficiency credit requirements for additions" is amended by 
deleting the subsection in its entirety.
The additional energy efficiency 
requirements will increase additional 
costs that are far exceed the 
negligible energy savings. 
Subsection R503.1.5 "Additional efficiency credit requirements for substantial improvements" is 
amended by deleting the subsection in its entirety.
The additional energy efficiency 
requirements will increase additional 
costs that are far exceed the 
negligible energy savings.
Model Code Changes:
Notes:
SECTION C403.7.8 – OCCUPANT SENSORS FOR VENTILATION was added to address that 
occupied-standby controls shall be required for each of the multipurpose rooms, office areas, 
break rooms, etc. and the ventilation air is allowed to be reduced to zero when the space is not 
occupied.
Reduce energy consumption when 
the space is unoccupied.
Local Amendments:
Notes:
CHAPTER 1 "SCOPE AND ADMINISTRATION" is amended by deleting in its entirety to comply 
with the provisions along with the amendments as described in the CHAPTER 1 SCOPE AND 
ADMINISTRATION of the 2024 International Building Code.
Eliminate the duplication and 
redundancy, we update only one 
administration chapter in the IBC and 
apply it for the other related codes.
Model Code Changes:
Notes:
No significant changes.
No significant changes.
Local Amendments:
Notes:
CHAPTER 1 "SCOPE AND ADMINISTRATION" is amended by deleting in its entirety to comply 
with the provisions along with the amendments as described in the CHAPTER 1 SCOPE AND 
ADMINISTRATION of the 2024 International Building Code.
Eliminate the duplication and 
redundancy, we update only one 
administration chapter in the IBC and 
apply it for the other related codes.
Model Code Changes:
Notes:
No significant changes.
No significant changes.
International 
Existing Building 
Code
International 
Swimming Pool 
and Spa Code
Page 10 of 10