February 8, 2023 MCP2022007 Page 1 of 3 Report to the Board of Supervisors Prepared by the Maricopa County Planning and Development Department Board Hearing Date: February 8, 2023 Case #/Title: MCP2022007 – Luke Field Warehouse Complex Supervisor District: 4 Applicant/Owner: Jay Irvin, Butler Design Group / Lincoln Property Company dba Northern Parkway Owner, LLC Request: Military Compatibility Permit for a warehouse complex in the IND-2 MAAMF & AD-2 MAAMF Zoning Districts Site Location: Generally located at the SEC of Litchfield Rd & Northern Ave. Site Size: 138.4 acres County Island Status: Yes, City of Glendale Additional Comments: The proposed Military Compatibility Permit (MCP) is to allow for the permitting of a 2.4 million sq. ft warehouse complex within the MAAMF. Luke Air Force Base (LAFB) approved a Use Compatibility and Consistency Determination for this use under UC2022011, subject to several recommendations that staff has worked with the applicant on addressing. There is no known opposition. Staff considers this site appropriate for the proposed use as much of the area surrounding LAFB has been developed for similar warehouse uses with little to no impact on base operations or any of the remaining nearby residences. Commission Recommendation: On 1/12/23, the Commission voted 8-0, to recommend approval of MCP2022007. If the Board finds that the proposal is compatible and consistent with the high noise or accident potential of the military airport or ancillary military facility, then the Commission recommends approval subject to conditions ‘a’ – ‘m’: a. Development of the site shall be in substantial conformance with the Site Plan entitled “Luke Field”, consisting of 1 full-size sheet, dated 10/10/22, except as modified by the following conditions. Staff may determine slight refinements to remain in substantial conformance with the approved site plan. Minor and major February 8, 2023 MCP2022007 Page 2 of 3 amendments to the site plan will be determined in accordance with Chapter 3 of the Maricopa County Zoning Ordinance. b. Development of the site shall be in substantial conformance with the Narrative Report entitled “Luke Field Project Narrative”, consisting of 3 pages, received 11/10/22 except as modified by the following conditions. c. Major amendments to the site plan will require a new UCCD and MCP application to be filed prior to any permit approvals. The incorporation of any other parcels into this project will require a lot combination, new UCCD, and new MCP prior to any additional permit approvals. d. No permits can be approved until a lot combination of APN 501-52-005J and APN 501-52-005H is complete. e. A revised site plan addressing all outstanding Planning concerns shall be submitted within 30 calendar days of approval of the Maricopa County Board of Supervisors. f. The following Military Airport and Ancillary Military Facility Overlay Zoning District standards shall apply: i. Max. Building Height: 55’ ii. Parking spaces required: 0.4 per 1,000 square feet of floor area for warehouse. Accessible spaces shall be provided in accordance with ordinance and ADA requirements. iii. Front/Rear Setback between LDN 80-84 to LDN 75-79(minimum): 0’/0’ iv. Front/Rear Setback between LDN 75-79 to LDN 70-74 (minimum): 0’/0’ v. Front/Rear Setback between AD-2 and IND-2 zoning: 0’/0’ vi. 6’ solid wall screening required for all outdoor industrial uses All other development standards of the underlying zoning shall remain g. The following Planning Engineering condition(s) shall apply: i. Engineering review of planning and/or zoning cases is for conceptual design only. All development and engineering design shall be in conformance with Section 1205 of the Maricopa County Zoning Ordinance; Drainage Policies and Standards; Floodplain Regulations for Maricopa County; MCDOT Roadway Design Manual; and current engineering policies, standards and best practices at the time of application for construction. ii. Based on the conceptual design nature of the information submitted, changes to the site layout may be necessitated by the final engineering design of the site’s drainage infrastructure. iii. Detailed Grading and Drainage (Site Infrastructure) Plans must be submitted with the application for Building Permits iv. MCDOT ROW permits to be obtained during building permit phase. v. Upon TIS approval from the City of Glendale (COG) and Luke Air Force Base (LAFB), provide a copy of the authorization to MCDOT. vi. It is the developer’s responsibility to ensure annexation and right of way dedication to COG on Litchfield Road. February 8, 2023 MCP2022007 Page 3 of 3 vii. The future classification of Northern Avenue along the site frontage is recorded as Principal Arterial. MCDOT reduced the classification upon the first TIS review to the Urban Minor Arterial with no sidewalk. Half-street improvements shall be as per RDM Figure 5.9 h. The following Maricopa County Environmental Services Department (MCESD) condition(s) shall apply: i. ATC for water and sewer improvements must be obtained prior to construction permit approval. i. Prior to issuance of a building permit, written confirmation will be required from the emergency fire protection jurisdiction having authority that the facility has been designed in accordance with their regulations and requirements, and that emergency fire protection service will be provided to the facility. Prior to issuance of the certificate of occupancy, local fire protection jurisdiction review and approval will be required. j. Noncompliance with any Maricopa County Regulation shall be grounds for initiating a revocation of this Military Compatibility Permit as set forth in the Maricopa County Zoning Ordinance. k. All new buildings are subject to noise attenuation as per ARS § 28-8482(B). l. The property owner/s and their successors waive claim for diminution in value if the County takes action to rescind approval due to noncompliance with conditions. m. The granting of this change in use of the property has been at the request of the applicant, with the consent of the landowner. The granting of this approval allows the property to enjoy uses in excess of those permitted by the zoning existing on the date of application, subject to conditions. In the event of the failure to comply with any condition, the property shall revert to the zoning that existed on the date of application. It is, therefore, stipulated and agreed that either revocation due to the failure to comply with any conditions, does not reduce any rights that existed on the date of application to use, divide, sell or possess the property and that there would be no diminution in value of the property from the value it held on the date of application due to such revocation of the MCP. The MCP enhances the value of the property above its value as of the date the MCP is granted and reverting to the prior zoning results in the same value of the property as if the MCP had never been granted. Presented by: Joel Landis, Planner Reviewed by: Darren Gerard, AICP, Planning Manager Attachment: 1/12/23 P&Z Packet (38 pages) Note: 1/12/23 Draft P&Z Minutes are not available as of the writing of this report, but can be provided upon request later when available. MCP2022007 Page 1 of 11 Report to the Planning and Zoning Commission Prepared by the Maricopa County Planning and Development Department Case: MCP2022007 – Luke Field Warehouse Complex Hearing Date: January 12, 2023 Supervisor Districts: 4 Applicant: Jay Irvin, Butler Design Group Owner: Lincoln Property Company dba Northern Parkway Owner, LLC Request: Military Compatibility Permit (MCP) with a Plan of Development (POD) for a warehouse complex within the IND-2 MAAMF & AD-2 MAAMF zoning districts Site Location: Generally located at the SEC of Litchfield Rd & Northern Ave. Site Size: Approx. 138.4 acres Density: N/A County Island: Yes, City of Glendale County Plan: White Tank Grand Avenue Area Plan – Military Compatible Municipal Plan: City of Glendale – Luke Compatible Municipal Comments: None received to date Support/Opposition: None known Recommendation: Approve with conditions MCP2022007 Page 2 of 11 Project Summary: 1. The applicant, Jay Irvin on behalf of Butler Design Group, is requesting a Military Compatibility Permit (MCP) with a Plan of Development (POD) to build an approximately 2.3 million sq. ft speculative warehouse development on 138.4 acres located northeast of Luke Air Force Base (LAFB). The warehouse complex will consist of up to three buildings: buildings A&B on the northern half of the parcel, which depending on a potential tenant may be combined into one building totaling a little over 1.1 million sq. ft, and building C on the southern half of the parcel totaling 1.278 million sq. ft. These buildings will cumulatively have 485 trailer spaces and accesses to the site will be provided from both Northern Ave. and Litchfield Rd. No specific occupants have been identified for the complex at the time of this report, but the applicant believes the granting of the subject entitlement and subsequent building permits will be critical to attracting potential tenants. The applicant has indicated that depending on the tenant, they may wish to combine buildings A&B into one larger structure through infilling the space between those buildings. This would have to be accomplished through a separate UCCD/MCP application. 2. The site is within the City of Glendale’s municipal planning area. The Glendale General Plan designates the property as Luke Compatible, which is applied to lands surrounding LAFB. Similarly, the county’s area plan designates the general area for Military Compatible land uses. This designation coincides with the Military Airbase and Ancillary Military Facility Overlay Zoning District (MAAMF) delineated by the 1988 Air Installation Compatible Use Zone (AICUZ) 80, 75, and 70 LDN noise contours. A portion of the lot on the northwest corner is within the clear zone meant to prevent development that would encroach on LAFB’s runways. Projects located within the MAAMF must first obtain a Use Compatibility and Consistency Determination (UCCD) prior to being able to apply for a Military Compatibility Permit (MCP). LAFB determined that this proposed warehouse use is consistent and compatible with the high noise or accident potential zone per UC2022011. 3. The earliest available aerial photography of the site from 1949 indicates it as farmland directly bordering LAFB to the southwest. Beginning in or around 2007, the overall site began to be formally developed as a plant nursery with several dozen greenhouse structures being erected. Additionally, a separate parcel on the north of the site, 501-52- 003A, was developed with a cell tower which appears to remain in use and is not part of the subject entitlement. The applicant filed and was approved for a UCCD from LAFB, UC2022011, in April of 2022. The applicant applied for the subject MCP with POD in September of 2022. Staff held a Technical Advisory Committee meeting with the applicant on October 4, 2022. MCP2022007 Page 3 of 11 4. The subject site is zoned IND-2 MAAMF & AD-2 MAAMF. The AD-2 portion of the site is the extreme southwest corner that does not impact development. It will only contain retention. The existing standards for the IND-2 MAAMF zoning district and proposed standards for the IND-2 MAAMF MCP are listed below: REGULATION BASE ZONING DISTRICT REGULATIONS (IND-2 MAAMF) PROPOSED ZONING DISTRICT REGULATIONS (IND-2 MAAMF MCP) Max. Height 40' 55’ Min. Front Yard 20’ 366’2” (W) Min. Side Yard 0’ 120’ (S) Min. Street-side Yard 10' 368’4” (N) Min. Rear Yard 25’ 63’ (E) Front/Rear Setback between LDN 80-84to LDN 75-79(minimum) 20’/25’ 0’/0’ Front/Rear Setback between LDN 75-79to LDN 70-74 (minimum) 20’/25’ 0’/0’ Front/Rear Setback between AD-2/IND-2 zoning districts 20’/25’ 0’/0’ Min. Lot Area 6,000 sq. ft. 6,031,168 sq. ft. Min. Lot Width 145’ 2,053’7” Max. Lot Coverage 60% 39.7% Parking Spaces Required 1 per 900 square feet of floor area for warehouse uses (5% are required to be ADA) 0.4 per 1,000 square feet of floor area for warehouse (5% are required to be ADA) Screening Adjacent to rural or residential zoning districts automobile parking shall be screened from view. Solid masonry wall, six feet in height adjacent to any side or rear property line abutting any rural or residential zoning district. View-obscuring wall or fence, six feet in height, on perimeter of site with outdoor industrial use adjacent to district other than rural or residential. 6’ solid wall screening required for all outdoor industrial uses Signs Chapter 14, Section 1404 Regulations Apply Chapter 14, Section 1404 Regulations Apply Landscaping Min. 5’ landscaping strip is required along road frontage Min. 5’ landscaping strip is required along road frontage Sight Visibility Triangles (SVTs) 25’x25’ SVT required for all corner lots and access points in accordance with Chapter 11, Articles 1111.4.1. through 1111.4.3. 25’x25’ SVT required for all corner lots and access points in accordance with Chapter 11, Articles 1111.4.1. through 1111.4.3. Pavement Pavement required for all driveways, parking spaces and access points Pavement required for all driveways, parking spaces and access points MCP2022007 Page 4 of 11 5. The applicant is requesting to vary the maximum height of the structure from 40’ to 55’ to accommodate taller internal racking heights. This height will also allow for a parapet to screen any visibility from site rooftops to on-base operations at LAFB. 6. The applicant is also requesting to vary parking requirements from 1 per 900 sq. ft of floor area for warehouse uses to 0.4 spaces for every 1,000 sq. ft of floor area arguing that the site would otherwise be overparked with far more spaces than active employees if built to County warehouse standards. Staff would note that the required ADA spaces are based off the original number of required parking spaces per Ordinance standards and are not based upon the varied parking. 7. Variances of the front/rear setbacks are required for the areas of the site that are LDN 80-84, 75-79, and 70-74, as these contour lines functionally serve as distinct zoning district boundary lines (as each noise contour is subject to different development standards within the MAAMF overlay zoning district). Development must meet setbacks, as approved as part of the MCP, from the IND-2 & AD-2 zoning district boundary line and from the noise contour MAAMF zoning district boundary lines. 8. As no new residential construction is allowed near LAFB within the MAAMF overlay and the site itself is not near any existing residential construction, only 6’ solid wall screening is required for any outdoor industrial uses as site activities will not otherwise disturb nearby residents. MCP2022007 Page 5 of 11 Exhibit 1 – 2022 Site Aerial MCP2022007 Page 6 of 11 Exhibit 2 – IND-2/AD-2 Military Airport and Ancillary Military Facility Overlay District & Surrounding Districts Exhibit 3 – Partial Site Plan of North Half of Site (Buildings A&B) – oriented North MCP2022007 Page 7 of 11 Exhibit 4 – Partial Site Plan of South Half of Site (Building C) – oriented North Existing On-Site and Adjacent Zoning / Land Use: 9. On-site: IND-2 MAAMF /AD-2 MAAMF / Vacant North: RU-43 MAAMF / Cell Tower South: Luke_AFB (City of Glendale) / Luke Air Force Base East: RU-43 MAAMF / Agricultural Land West: Luke_AFB (City of Glendale) / Luke Air Force Base Utilities and Services: 10. Water: Valley Utilities Wastewater: Liberty Water School District/s: Dysart Unified School District Fire: Rural Metro Police: MSCO Right-of-Way: 11. The following table includes existing and proposed half-width right-of-way and the future classification based upon the Maricopa County Department of Transportation (MCDOT) Major Streets and Routes Plan. Litchfield Rd is under the City of Glendale’s jurisdiction. Street Name Half-width Existing R/W Half-width Proposed R/W Future Classification Northern Ave. 33’ 55’ Urban Minor Arterial Adopted Plan[s]: 12. Maricopa County Vision 2030 (Adopted: 2016): Rural Development Area (0-1 d.u./ac) MCP2022007 Page 8 of 11 13. City of Glendale General Plan (Revised: 2016): This plan identifies the subject parcel as a Luke Compatible Land Use Area. Luke Air Force Base must issue a Use Consistency and Compatibility Determination (UCCD) prior to a use being allowed in this area. Public Participation Summary: 14. The applicant has complied with the Maricopa County Citizen Review Process with the required posting of the site and notification by first class mail to adjacent property owners and HOA’s within 300’ of the subject parcel and notification to interested parties. Two signs were posted on site in accordance with applicable regulations. A Public Participation Results Report was submitted to Staff in accordance with County requirements. 15. Staff received no letters in support or opposition to the request. 16. LAFB sent staff comments stating that the request will not negatively impact flying operations at the base. As part of both the UCCD and MCP applications, LAFB staff included several potential mission risks and hazards: a. Retention ponds or other features that would attract wildlife – Birds pose an aircraft strike hazard and are incompatible with flying operations. b. Light interference – Buildings or structures that would produce light interference at night and or glint/glare during the day that would distract or interfere with pilot vision. c. Spectrum utilization and radio frequency interference – Buildings or structures that would cause a loss of radar coverage such that it interferes with spectrum utilization. Additionally, to avoid radio frequency interference, developers and or end users should not use radio equipment that would interfere with Luke’s frequency or operate on a military frequency. d. Displaced water resulting in flooding – Development that would displace water or storm runoff in such a manner that it overflows onto the base, particularly areas near our runway. Besides direct effect of flooding, it also creates an opportunity for the pooling of water, which could attract birds near our runway. e. Physical encroachment – Personnel standing on the top of the buildings could potentially surveille base activities. Cameras placed on top of building structures present a potential danger to military operations. When the time comes, Luke Security Forces personnel can provide a list of National Defense Authorization Act (NDAA) compliant security/surveillance equipment that would work best for our operations. f. Impairment of pilot’s visibility – Any production that would release substances into the air that would impair visibility or otherwise interfere with operating aircraft such as: steam, dust or smoke. These items create a negative impact and should be eliminated. 17. Planning and Engineering staff have worked with the applicant on mitigating these issues in the design phase to mollify LAFB’s concerns. Such mitigations include parapets along the roofs of each warehouse structure to limit base observation, the usage of access codes to access the site instead of radios, orienting any potential illuminated signs away from the base, light mitigation to prevent light encroachment beyond parcel lines, and MCP2022007 Page 9 of 11 drainage design that would limit fowl and other animals from becoming potential strike hazards for incoming and outgoing air traffic. Outstanding Concerns from Reviewing Agencies: 18. Staff still has concerns regarding some aspects of the site design and narrative and is working with the applicant on addressing these concerns. To that end, staff is requesting to allow the applicant to submit a final site plan and narrative within thirty days of calendar approval by the Board of Supervisors. It must be noted that these changes are minor and will not affect the site layout or building design. Staff Analysis: 19. Staff believes that the proposed industrial warehouse use is appropriate for the site. LAFB found that the proposed land use consistent and compatible with the High Noise and Accident Potential Zone of the base, and that the proposal would not negatively impact flying operations. As such, Maricopa County can make a similar determination of compatibility and consistency. Several industrial developments in both Maricopa County and Glendale jurisdictions have been constructed in recent years in the vicinity of LAFB that have had little to no impact on base operations or the remaining nearby residences and have otherwise provided thousands of jobs in the west Valley. Recommendation: 20. Staff recommends the Commission adopt a motion recommending that the Board of Supervisors approve MCP2022007 subject to the following conditions ‘a’ – ‘m’: a. Development of the site shall be in substantial conformance with the Site Plan entitled “Luke Field”, consisting of 1 full-size sheet, dated 10/10/22, except as modified by the following conditions. Staff may determine slight refinements to remain in substantial conformance with the approved site plan. Minor and major amendments to the site plan will be determined in accordance with Chapter 3 of the Maricopa County Zoning Ordinance. b. Development of the site shall be in substantial conformance with the Narrative Report entitled “Luke Field Project Narrative”, consisting of 3 pages, received 11/10/22 except as modified by the following conditions. c. Major amendments to the site plan will require a new UCCD and MCP application to be filed prior to any permit approvals. The incorporation of any other parcels into this project will require a lot combination, new UCCD, and new MCP prior to any additional permit approvals. d. No permits can be approved until a lot combination of APN 501-52-005J and APN 501-52-005H is complete. e. A revised site plan addressing all outstanding Planning concerns shall be submitted within 30 calendar days of approval of the Maricopa County Board of Supervisors. MCP2022007 Page 10 of 11 f. The following Military Airport and Ancillary Military Facility Overlay Zoning District standards shall apply: i. Max. Building Height: 55’ ii. Parking spaces required: 0.4 per 1,000 square feet of floor area for warehouse. Accessible spaces shall be provided in accordance with ordinance and ADA requirements. iii. Front/Rear Setback between LDN 80-84 to LDN 75-79(minimum): 0’/0’ iv. Front/Rear Setback between LDN 75-79 to LDN 70-74 (minimum): 0’/0’ v. Front/Rear Setback between AD-2 and IND-2 zoning: 0’/0’ vi. 6’ solid wall screening required for all outdoor industrial uses All other development standards of the underlying zoning shall remain g. The following Planning Engineering condition(s) shall apply: i. Engineering review of planning and/or zoning cases is for conceptual design only. All development and engineering design shall be in conformance with Section 1205 of the Maricopa County Zoning Ordinance; Drainage Policies and Standards; Floodplain Regulations for Maricopa County; MCDOT Roadway Design Manual; and current engineering policies, standards and best practices at the time of application for construction. ii. Based on the conceptual design nature of the information submitted, changes to the site layout may be necessitated by the final engineering design of the site’s drainage infrastructure. iii. Detailed Grading and Drainage (Site Infrastructure) Plans must be submitted with the application for Building Permits iv. MCDOT ROW permits to be obtained during building permit phase. v. Upon TIS approval from the City of Glendale (COG) and Luke Air Force Base (LAFB), provide a copy of the authorization to MCDOT. vi. It is the developer’s responsibility to ensure annexation and right of way dedication to COG on Litchfield Road. vii. The future classification of Northern Avenue along the site frontage is recorded as Principal Arterial. MCDOT reduced the classification upon the first TIS review to the Urban Minor Arterial with no sidewalk. Half-street improvements shall be as per RDM Figure 5.9 h. The following Maricopa County Environmental Services Department (MCESD) condition(s) shall apply: i. ATC for water and sewer improvements must be obtained prior to construction permit approval. i. Prior to issuance of a building permit, written confirmation will be required from the emergency fire protection jurisdiction having authority that the facility has been designed in accordance with their regulations and requirements, and that emergency fire protection service will be provided to the facility. Prior to issuance of the certificate of occupancy, local fire protection jurisdiction review and approval will be required. MCP2022007 Page 11 of 11 j. Noncompliance with any Maricopa County Regulation shall be grounds for initiating a revocation of this Military Compatibility Permit as set forth in the Maricopa County Zoning Ordinance. k. All new buildings are subject to noise attenuation as per ARS § 28-8482(B). l. The property owner/s and their successors waive claim for diminution in value if the County takes action to rescind approval due to noncompliance with conditions. m. The granting of this change in use of the property has been at the request of the applicant, with the consent of the landowner. The granting of this approval allows the property to enjoy uses in excess of those permitted by the zoning existing on the date of application, subject to conditions. In the event of the failure to comply with any condition, the property shall revert to the zoning that existed on the date of application. It is, therefore, stipulated and agreed that either revocation due to the failure to comply with any conditions, does not reduce any rights that existed on the date of application to use, divide, sell or possess the property and that there would be no diminution in value of the property from the value it held on the date of application due to such revocation of the MCP. The MCP enhances the value of the property above its value as of the date the MCP is granted and reverting to the prior zoning results in the same value of the property as if the MCP had never been granted. Presented by: Joel Landis, Planner Reviewed by: Darren Gerard, AICP, Planning Manager Attachments: Case Map (1 page) Site Plan (1 page) Narrative Report (3 pages) Architectural Elevations (4 pages) Utility Plan (7 pages) Engineering/MCDOT comments (2 pages) MCESD comments (1page) Luke AFB correspondence (2 pages) MARICOPA COUNTY / Maricopa County Planning & Development - Phoenix, AZ 4 Gross Acres: 138.5 approx. Generated December 22, 2022 11:05 AM MCP2022007 Application Name: Legal Description Luke Field EDR Applicant Case Address , Jay Irvin for Butler Design Group 13803 W NORTHERN Ave Applicant Phone/Email Parcel Primary: 160.299.9292 jirvin@butlerdesigngroup.com GLENDALE AZ 85307 Map scale 1:6,600 Supervisor District No. 501-52-005H, 501-52-005J 3 GRAY SHELL WAREHOUSE BUILDINGS TOTLALING APPROX. 2.4 MILLION SQUARE FEET 5.3585 in 3131 East Camelback Road, Suite 318 | Phoenix, Arizona 85016 | 602.912.8888 Luke Field Project Narrative Project Name: Luke Field Address: 13803 Northern Avenue – Glendale, AZ 307 Case # MCP2022007 Vicinity Map: Purpose of Request: Obtain site plan approval and zoning variance approval in order to allow the submission of construction documents for permit review and approval. Description of Proposal: Luke Field is a three-building speculative development constructed in a single phase, consisting of approximately 2,280,000 total s.f. of industrial warehouse / distribution, planned on a 137.6-acre site at the SWC of N. Litchfield Road and W. Northern Avenue. Building A, which is 604,000 s.f. and Building B, which is 416,000 s.f., will be approximately 1,079,000 s.f. if combined. These two buildings are designed with the ability to be combined into one larger building in the future for market flexibility. Building C will be 1,260,000 s.f. All three buildings are cold dark gray shell spec. industrial buildings. Buildings A and B are designed with the ability to combine them into one larger building for the potential to attract larger national tenants. No specific tenant has been identified at this point but developing the design and obtaining entitlement and permits is critical to marketing the project. All three buildings will have 40-feet clear heights with approximate buildings heights (top of parapets) at approximately 55-feet. The three industrial buildings are speculative in nature and hours of operation, number of employees and specific warehousing use will be determined once a tenant occupies the building. 3131 East Camelback Road, Suite 318 | Phoenix, Arizona 85016 (602) 912-8888 Telephone | (602) 912-8870 Facsimile Relationship to Surrounding Properties: The Luke Field industrial development is located at the SEC of Litchfield Road and Northern Avenue. The Loop 303 corridor has seen tremendous industrial development within the last 10 years along the Loop 303 corridor and explosive growth within the last five years. These industrial / warehouse developments support local job growth, tax revenue and provide economic engines for both the greater Phoenix area and Arizona in general. Arizona is a top five destination nationally for industrial development. Our neighbor to the East is Luke Air Force Base and to the West is a similar size industrial development by Clarion Partners. To the North is a property owned by the City of Phoenix and to the South is housing for Luke Air Force Base. This development is consistent in nature with surrounding growth and developments. Location, Accessibility and Site Circulation: Access to the project site will be from both Litchfield Road and Northern Avenue. The project will have three main access points along Northern Avenue which will serve as the access points for trucks for Buildings A and B. Litchfield Road will have multiple access points for all three buildings. The multiple access points along Litchfield Road are intended to separate car and truck traffic for safety purposes. All access points along Litchfield Road and Northern Avenue are accessible to the fire department for fire access. Two of the access points along Litchfield Road are designed to have a potential future guard house to create a secured yard and should be entitled with flexibility, dependent on specific future tenant needs. For all three buildings, a single row of trailer storage will be provided on the North and South sides of the dock areas of each building to create cross dock buildings with trailer storage on both sides each building. There are also potential future trailer storage areas located on the North side of buildings A and B and on the South side of building C. There is ample queuing for semi-trucks that is provided along with any required screen walls facing public right- of-way’s and at other dock / trailer areas. Screen walls will be used along the perimeter of all dock areas for both security and screening. All buildings will have a fire lane that encompasses the entire perimeter of all buildings, which will provide code required access and clearances for the fire department. On-site storm water retention will be provided along the edges of the property in designated retention basins. Development Schedule: We are anticipating the start of construction in early Q1 of 2023 with an approximate construction schedule of 14 months. Construction is anticipated to be completed in Q2 of 2024. All three buildings will be built in one single phase, no phasing is anticipated for this project based on current market conditions. Community Facilities and Services: There will be no community facilities provided for the public with-in the Luke Field industrial/warehouse development. Public Utilities and Services: Sewer service will be provided by Liberty. LPC and our neighboring industrial development to the East, by Clarion Partners are working jointly to extend sewer to both industrial developments. LPC and Clarion Partners are also working jointly with Valley Utilities to extend domestic water to both industrial developments. Both developers have already started the sewer and water extension service agreements with both Liberty and Valley. Rural Metro will be the servicing fire department for our development. Refuse service will be by a private third-party vendor. Elevation Design: The design of the building elevations will provide flexibility to create primary tenant entries at either of the building corners facing Litchfield Road. The prominent entries at the buildings will feature 24’ tall low ‘e’ glazing with a clean and simple steel canopy, using accent tilt panels at each entry which tie into a theme to create cohesiveness amongst all the buildings. The higher volume of glass can adequately accommodate a second level 3131 East Camelback Road, Suite 318 | Phoenix, Arizona 85016 (602) 912-8888 Telephone | (602) 912-8870 Facsimile of office at the entry should a tenant desire. The perimeter of the warehouse will have clerestory windows along the perimeter which provide both natural light into the warehouse and an aesthetic and modern appeal to any potential user. A mix of cool grey color tones, along with a series of reveals and punched openings, will further break down the mass of the concrete tilt-up concrete, currently scheduled to be a 40’ clear height based on tenant-driven market standards. Optional tenant entries may be added to the East corners of the buildings if future tenant leasing dictates. All buildings will have a cohesive and aesthetically pleasing architectural design which provide an attractive visual along Northern Avenue, Litchfield Road and Northern Parkway. Submittal of civil and building permit plans is anticipated in Q4 of 2022. Zoning Variance Request for IND-2 Zoning: Article 902.3 – Height Regulations: Allowed Height 40’-0” Proposed Height (top of parapet) 55’-0” Justification: Current industrial developments larger than 250,000 s.f. in size require higher building clear heights to accommodate taller internal racking heights. 55’-0” to the top of the building parapet will accommodate the 40’-0” clear heights required for modern industrial developments. The 55’-0” building height will also allow us to screen the view from a maintenance worker standing on top of the roof. The 55’-0” parapet height will screen any visibility from our roof top. See the attached sight line study exhibit for reference. Article 1111.2 – Building Appurtenances: Allowed height 100’-0” Proposed height: 80’-0” Justification: Building appurtenances are not specifically identified for IND-2 zoning. We are requesting building appurtenances for IND-2 be identified as silos, cooling towers, or similar equipment towers that shall be located adjacent to the proposed buildings. Article 1102.1.5 – Industrial, Wholesale and Manufacturing Uses: Required Parking One per 600 square feet of floor area, with 5% of parking spaces to be ADA accessible. Proposed Parking 0.4 spaces for every 1,000 s.f. of space. and 2% of parking spaces to be ADA to match the 2010 ADA Standards for Accessible Design. Justification: Current industrial developments are larger in size due to the requirement of more warehouse racking/storage space. The size of the building does not have a direct correlation to parking space requirements. Current e-commerce buildings will have a typical workforce of approximately 600 – 800 employees. This workforce is typically based up 2-3 *-hour shifts. The average workforce is 0.5 parking spaces per every 1,000 s.f. of warehouse space. Our current site plan supports this development. An “alternative” parking plan is being provided to show in the event additional parking is required on site beyond what we are providing, it can be accommodated. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 PT1 FF1 PT2 PT2 PT1 PT3 PT2 GL1 PT2 PT4 PT1 PT2 PT4 TYP 0308 TYP 2201 0506 TYP 0703 TYP 0801 TYP 0803 TYP 0804 TYP 0805 TYP 2601 F.F. 0" T.O.P. 51' - 0" T.O.P. 48' - 0" T.O.P. 50' - 0" DOCK -4' - 0" C B A D E F G H I J K N M GL1 T.O.P. 49' - 0" F.F. 0" T.O.P. 51' - 0" T.O.P. 53' - 0" T.O.P. 55' - 0" T.O.P. 51' - 0" T.O.P. 53' - 0" PT3 PT1 PT2 PT2 PT4 PT3 PT1 PT2 PT1 PT3 TYP 0703 TYP 0308 TYP 0805 TYP 2601 TYP 0801 TYP 0318 0506 0508 C B A D E F G H I J K N M T.O.P. -4' - 0" T.O.P. 50' - 0" T.O.P. 53' - 0" T.O.P. 55' - 0" PT1 PT2 PT3 PT4 PT2 GL1 PT2 PT1 TYP 0703 TYP 0805 TYP 0308 TYP 2601 PT1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 T.O.P. 50' - 0" DOCK -4' - 0" T.O.P. 48' - 0" T.O.P. 50' - 0" T.O.P. 49' - 0" T.O.P. 50' - 0" F.F. 0" PT1 PT2 PT3 GL1 PT1 PT2 PT1 PT2 PT2 FF1 PT4 TYP 0703 TYP 0308 TYP 0804 TYP 0803 TYP 0802 TYP 2201 TYP 0802 TYP 2602 TYP 0805 TYP 2601 TYP 2603 GENERAL ELEVATION NOTES A. SEE ENLARGED ELEVATIONS, DETAILS, AND WALL SECTIONS FOR ADDITIONAL INFORMATION IN RELATIONSHIP TO EXTERIOR CONDITIONS. B. GRADES AT PERIMETER OF BUILDING ARE TO BE COORDINATED WITH THE CIVIL DOCUMENTS FOR ACTUAL FINISH GRADE LOCATIONS. C. TOP OF PARAPET IS BASED ON ELEVATIONS ABOVE FINISHED FLOOR. D. SEE DOOR AND WINDOW SCHEDULES AND ELEVATIONS FOR ADDITIONAL INFORMATION IN RELATIONSHIP TO TYPE AND STYLE. E. ALL DIMENSIONS SHOWN FOR LOCATIONS OF FINISH OF EXTERIOR ELEMENTS ARE TO BE COORDINATED WITH ARCHITECTURAL FLOOR PLANS, DETAILS, AND SECTIONS. F. REFER TO WINDOW TYPES FOR TEMPERED GLASS LOCATIONS. G. PAINT TRANSITIONS ARE TO BE COORDINATED WITH THE ARCHITECT PRIOR TO APPLICATION. H. SEE ELECTRICAL DOCUMENTS FOR EXTERIOR LIGHTING FIXTURES, THE LOCATIONS SHOWN ON THE EXTERIOR ELEVATIONS AND WALL SECTIONS SHALL BE USED AT ALL LOCATIONS. I. PROVIDE BUILDING ADDRESS NUMBERS AT STREET SIDE OF BULDING AND OTHER LOCATIONS AS SHOWN ON THE EXTERIOR ELEVATIONS. NUMBERS SHALL BE A MINIMUM OF 12" HIGH REVERSED PAN CHANNEL IN CONTRASTING COLORS. J. SEE SITE PLAN AND HARDSCAPE PLANS FOR ADDITIONAL ALIGNMENT ITEMS IN RELATIONSHIP TO THE BUILDING TO SITE RELATED HORIZONTAL CONTROL. K. SIGNAGE BY OTHERS, TO BE PERMITTED BY OTHERS. PROVIDE ELECTRICAL AS REQUIRED. L. ALL EXPOSED METAL PLATES AND EXPOSED FLASHING ARE TO BE PAINTED TO MATCH ADJACENT BUILDING COLOR, UNLESS NOTED OTHERWISE. M. ALL SITE EQUIPMENT SHALL BE PAINTED TO MATCH ADJACENT BUILDING, SITE WALL, ETC. N. WHEN TWO DISSIMILAR MATERIALS ABUT, JOINT SEALANT TO BE COLOR MATCHED TO THE MATERIAL IN THE SAME PLANE AS THE SEALANT. O. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) TO BE FREE OF DEFECTS, STAMPS, MARKS AND IMPERFECTIONS. P. ALL EXPOSED WELDS TO BE CONTINUOUS OR OF EQUAL LENGTH AND SPACING. BONDO FILLER MAY BE REQUIRED TO MIMIC WELDS AT SOME LOCATIONS. Q. SPLICING OF EXPOSED STEEL ELEMENTS, IF NECESSARY, TO BE CONTINUOUS AND GROUND SMOOTH All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by the design professional as instruments of service shall remain the property of the design professional. The design professional shall retain all common law, statutory and other reserved rights, including the copyright thereto. OWNERSHIP OF INSTRUMENTS OF SERVICE PRELIMINARY NOT FOR CONSTRUCTION 602-957-1800 Phoenix, Arizona 85034 5017 East Washington St. #107 architects & planners Phone Butler Design Group Inc. Revisions: Title: Drawn By: Project Number: Date: Case #: Plan Check #: Submittal: AA301 BLDG A - EXTERIOR ELEVATIONS 22025 10/10/2022 LUKE FIELD BUILDINGS A, B & C MARICOPA COUNTY MILITARY COMPATIBILITY # X MATERIAL / COLOR SCHEDULE # ELEVATION KEYNOTES SCALE: 1" = 40'-0" 1 BLDG A - NORTH ELEVATION SCALE: 1" = 40'-0" 3 BLDG A - WEST ELEVATION SCALE: 1" = 40'-0" 2 BLDG A - EAST ELEVATION SCALE: 1" = 40'-0" 4 BLDG A - SOUTH ELEVATION MARK DESCRIPTION FINISH/COLOR MODEL MANUFACTURER COMMENTS GLAZING GL1 1" INSULATED GLAZING TINTED BLUE - - - MASONRY MU1 8x8x16 CONCRETE MASONRY UNITS PEBBLE BEACH TRENDSTONE ECHELON MASONRY - PAINT FF1 FACTORY FINISH O.H.D. (WHITE) MANUFACTURER FINISH - - - PT1 CONC. TILT PANEL - PAINTED FOSSIL DE6365 DUNN EDWARDS - PT2 CONC. TILT PANEL - PAINTED WALRUS DE6368 DUNN EDWARDS - PT3 CONC. TILT PANEL - PAINTED SO CHIC! DET614 DUNN EDWARDS - PT4 CONC. TILT PANEL - PAINTED CHARCOAL SMUDGE DE6370 DUNN EDWARDS - PT5 CONC. TILT PANEL - PAINTED BLACK TIE DE6357 DUNN EDWARDS - 0308 PAINTED CONCRETE TILT-PANEL - TYP. 0318 CONCRETE TILT PANEL KNOCKOUT 0506 PAINTED STEEL CANOPY - SEE REFLECTED CANOPY/CEILING PLANS 0508 ALTERNATIVE ADDITION FOR THE ENTRY CANOPY 0703 DASHED LINE OF ROOF, AND FUTURE MECHANICAL UNITS BEYOND. MECHANICAL UNITS TO BE FULLY SCREENED FROM VIEW 0801 ALUMINUM STOREFRONT SYSTEM - SEE WINDOW TYPES 0802 HOLLOW METAL DOOR - PAINTED. SEE ELEVATIONS FOR FINISH INFORMATION. 0803 FACTORY FINISHED 9'X10' OVERHEAD SECTIONAL DOOR. SEE DOOR TYPES. 0804 FACTORY FINISHED 12'X14' OVERHEAD SECTIONAL DOOR. SEE DOOR TYPES. 0805 ALUMINUM FRAMED WINDOW - SEE WINDOW TYPES. 2201 SCUPPER BOX AND DOWN SPOUT - SEE ELEVATIONS 2601 WALL PACK LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS 2602 TRANSFORMER 2603 SERVICE ENTRANCE SECTION ON CONCRETE PAD. PAINT TO MATCH BUILDING PAINT COLOR. SEE ELECTRICAL DWGS. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 T.O.P. 50' - 0" DOCK -4' - 0" T.O.P. 48' - 0" T.O.P. 50' - 0" T.O.P. 51' - 0" F.F. 0" PT1 FF1 PT2 PT4 PT3 GL1 PT2 PT4 PT2 PT3 PT4 PT2 TYP 0804 TYP 0803 TYP 0703 TYP 0802 TYP 2201 TYP 0805 TYP 0308 0506 TYP 2601 TYP 0801 B C D E F G H I J K A L M T.O.P. 51' - 0" T.O.P. 53' - 0" T.O.P. 53' - 0" T.O.P. 55' - 0" PT1 ? PT2 PT1 PT3 PT2 GL1 PT1 PT4 PT2 TYP 2601 TYP 0703 TYP 0308 TYP 0805 TYP 0801 0506 0508 TYP 0318 B C D E F G H I J K A L M DOCK -4' - 0" T.O.P. 49' - 0" T.O.P. 50' - 0" T.O.P. 53' - 0" T.O.P. 55' - 0" T.O.P. 50' - 0" F.F. 0" PT1 PT2 GL1 PT3 PT2 PT2 PT1 PT4 PT4 TYP 0703 TYP 2601 TYP 0805 TYP 0308 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PT3 PT4 PT2 PT1 PT2 FF1 PT2 GL1 PT4 PT2 PT1 PT3 PT2 F.F. 0" T.O.P. 49' - 0" T.O.P. 50' - 0" T.O.P. 48' - 0" T.O.P. 50' - 0" DOCK -4' - 0" TYP 0804 TYP 0802 TYP 2601 TYP 2201 TYP 0308 TYP 0703 TYP 0805 TYP 2603 TYP 2602 FF1 GENERAL ELEVATION NOTES A. SEE ENLARGED ELEVATIONS, DETAILS, AND WALL SECTIONS FOR ADDITIONAL INFORMATION IN RELATIONSHIP TO EXTERIOR CONDITIONS. B. GRADES AT PERIMETER OF BUILDING ARE TO BE COORDINATED WITH THE CIVIL DOCUMENTS FOR ACTUAL FINISH GRADE LOCATIONS. C. TOP OF PARAPET IS BASED ON ELEVATIONS ABOVE FINISHED FLOOR. D. SEE DOOR AND WINDOW SCHEDULES AND ELEVATIONS FOR ADDITIONAL INFORMATION IN RELATIONSHIP TO TYPE AND STYLE. E. ALL DIMENSIONS SHOWN FOR LOCATIONS OF FINISH OF EXTERIOR ELEMENTS ARE TO BE COORDINATED WITH ARCHITECTURAL FLOOR PLANS, DETAILS, AND SECTIONS. F. REFER TO WINDOW TYPES FOR TEMPERED GLASS LOCATIONS. G. PAINT TRANSITIONS ARE TO BE COORDINATED WITH THE ARCHITECT PRIOR TO APPLICATION. H. SEE ELECTRICAL DOCUMENTS FOR EXTERIOR LIGHTING FIXTURES, THE LOCATIONS SHOWN ON THE EXTERIOR ELEVATIONS AND WALL SECTIONS SHALL BE USED AT ALL LOCATIONS. I. PROVIDE BUILDING ADDRESS NUMBERS AT STREET SIDE OF BULDING AND OTHER LOCATIONS AS SHOWN ON THE EXTERIOR ELEVATIONS. NUMBERS SHALL BE A MINIMUM OF 12" HIGH REVERSED PAN CHANNEL IN CONTRASTING COLORS. J. SEE SITE PLAN AND HARDSCAPE PLANS FOR ADDITIONAL ALIGNMENT ITEMS IN RELATIONSHIP TO THE BUILDING TO SITE RELATED HORIZONTAL CONTROL. K. SIGNAGE BY OTHERS, TO BE PERMITTED BY OTHERS. PROVIDE ELECTRICAL AS REQUIRED. L. ALL EXPOSED METAL PLATES AND EXPOSED FLASHING ARE TO BE PAINTED TO MATCH ADJACENT BUILDING COLOR, UNLESS NOTED OTHERWISE. M. ALL SITE EQUIPMENT SHALL BE PAINTED TO MATCH ADJACENT BUILDING, SITE WALL, ETC. N. WHEN TWO DISSIMILAR MATERIALS ABUT, JOINT SEALANT TO BE COLOR MATCHED TO THE MATERIAL IN THE SAME PLANE AS THE SEALANT. O. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) TO BE FREE OF DEFECTS, STAMPS, MARKS AND IMPERFECTIONS. P. ALL EXPOSED WELDS TO BE CONTINUOUS OR OF EQUAL LENGTH AND SPACING. BONDO FILLER MAY BE REQUIRED TO MIMIC WELDS AT SOME LOCATIONS. Q. SPLICING OF EXPOSED STEEL ELEMENTS, IF NECESSARY, TO BE CONTINUOUS AND GROUND SMOOTH All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by the design professional as instruments of service shall remain the property of the design professional. The design professional shall retain all common law, statutory and other reserved rights, including the copyright thereto. OWNERSHIP OF INSTRUMENTS OF SERVICE PRELIMINARY NOT FOR CONSTRUCTION 602-957-1800 Phoenix, Arizona 85034 5017 East Washington St. #107 architects & planners Phone Butler Design Group Inc. Revisions: Title: Drawn By: Project Number: Date: Case #: Plan Check #: Submittal: AB301 BLDG B - EXTERIOR ELEVATIONS 22025 10/10/2022 LUKE FIELD BUILDINGS A, B & C MARICOPA COUNTY MILITARY COMPATIBILITY # X MATERIAL / COLOR SCHEDULE # ELEVATION KEYNOTES SCALE: 1" = 40'-0" 1 BLDG B - NORTH ELEVATION SCALE: 1" = 40'-0" 2 BLDG B - EAST ELEVATION SCALE: 1" = 40'-0" 3 BLDG B - WEST ELEVATION SCALE: 1" = 40'-0" 4 BLDG B - SOUTH ELEVATION MARK DESCRIPTION FINISH/COLOR MODEL MANUFACTURER COMMENTS GLAZING GL1 1" INSULATED GLAZING TINTED BLUE - - - MASONRY MU1 8x8x16 CONCRETE MASONRY UNITS PEBBLE BEACH TRENDSTONE ECHELON MASONRY - PAINT FF1 FACTORY FINISH O.H.D. (WHITE) MANUFACTURER FINISH - - - PT1 CONC. TILT PANEL - PAINTED FOSSIL DE6365 DUNN EDWARDS - PT2 CONC. TILT PANEL - PAINTED WALRUS DE6368 DUNN EDWARDS - PT3 CONC. TILT PANEL - PAINTED SO CHIC! DET614 DUNN EDWARDS - PT4 CONC. TILT PANEL - PAINTED CHARCOAL SMUDGE DE6370 DUNN EDWARDS - PT5 CONC. TILT PANEL - PAINTED BLACK TIE DE6357 DUNN EDWARDS - 0308 PAINTED CONCRETE TILT-PANEL - TYP. 0318 CONCRETE TILT PANEL KNOCKOUT 0506 PAINTED STEEL CANOPY - SEE REFLECTED CANOPY/CEILING PLANS 0508 ALTERNATIVE ADDITION FOR THE ENTRY CANOPY 0703 DASHED LINE OF ROOF, AND FUTURE MECHANICAL UNITS BEYOND. MECHANICAL UNITS TO BE FULLY SCREENED FROM VIEW 0801 ALUMINUM STOREFRONT SYSTEM - SEE WINDOW TYPES 0802 HOLLOW METAL DOOR - PAINTED. SEE ELEVATIONS FOR FINISH INFORMATION. 0803 FACTORY FINISHED 9'X10' OVERHEAD SECTIONAL DOOR. SEE DOOR TYPES. 0804 FACTORY FINISHED 12'X14' OVERHEAD SECTIONAL DOOR. SEE DOOR TYPES. 0805 ALUMINUM FRAMED WINDOW - SEE WINDOW TYPES. 2201 SCUPPER BOX AND DOWN SPOUT - SEE ELEVATIONS 2601 WALL PACK LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS 2602 TRANSFORMER 2603 SERVICE ENTRANCE SECTION ON CONCRETE PAD. PAINT TO MATCH BUILDING PAINT COLOR. SEE ELECTRICAL DWGS. 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 / 2 AC301 / 3 AC301 C B A D E F G H I J K L M N DOCK -4' - 0" T.O.P. 50' - 0" T.O.P. 53' - 0" T.O.P. 55' - 0" T.O.P. 50' - 0" F.F. 0" TYP 0318 PT2 PT1 PT2 PT4 PT3 PT1 PT2 PT1 TYP 2601 TYP 0318 TYP 0703 TYP 0805 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 / 3 AC301 PT1 PT3 PT2 PT2 FF1 PT2 GL1 PT4 PT1 TYP 0803 TYP 0802 TYP 0804 TYP 2201 TYP 0805 TYP 0703 TYP 0308 TYP 2601 T.O.P. 50' - 0" DOCK -4' - 0" T.O.P. 48' - 0" T.O.P. 50' - 0" T.O.P. 50' - 0" F.F. 0" TYP 0318 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 / 2 AC301 PT1 PT2 FF1 GL1 PT2 PT2 PT1 PT3 PT4 PT1 PT2 FF1 T.O.P. 51' - 0" T.O.P. 0" PT1 T.O.P. 48' - 0" T.O.P. 50' - 0" TYP 0804 TYP 0803 TYP 0802 TYP 0703 TYP 0308 TYP 2201 TYP 2601 0506 MU1 TYP 0801 TYP 2602 TYP 2603 GENERAL ELEVATION NOTES A. SEE ENLARGED ELEVATIONS, DETAILS, AND WALL SECTIONS FOR ADDITIONAL INFORMATION IN RELATIONSHIP TO EXTERIOR CONDITIONS. B. GRADES AT PERIMETER OF BUILDING ARE TO BE COORDINATED WITH THE CIVIL DOCUMENTS FOR ACTUAL FINISH GRADE LOCATIONS. C. TOP OF PARAPET IS BASED ON ELEVATIONS ABOVE FINISHED FLOOR. D. SEE DOOR AND WINDOW SCHEDULES AND ELEVATIONS FOR ADDITIONAL INFORMATION IN RELATIONSHIP TO TYPE AND STYLE. E. ALL DIMENSIONS SHOWN FOR LOCATIONS OF FINISH OF EXTERIOR ELEMENTS ARE TO BE COORDINATED WITH ARCHITECTURAL FLOOR PLANS, DETAILS, AND SECTIONS. F. REFER TO WINDOW TYPES FOR TEMPERED GLASS LOCATIONS. G. PAINT TRANSITIONS ARE TO BE COORDINATED WITH THE ARCHITECT PRIOR TO APPLICATION. H. SEE ELECTRICAL DOCUMENTS FOR EXTERIOR LIGHTING FIXTURES, THE LOCATIONS SHOWN ON THE EXTERIOR ELEVATIONS AND WALL SECTIONS SHALL BE USED AT ALL LOCATIONS. I. PROVIDE BUILDING ADDRESS NUMBERS AT STREET SIDE OF BULDING AND OTHER LOCATIONS AS SHOWN ON THE EXTERIOR ELEVATIONS. NUMBERS SHALL BE A MINIMUM OF 12" HIGH REVERSED PAN CHANNEL IN CONTRASTING COLORS. J. SEE SITE PLAN AND HARDSCAPE PLANS FOR ADDITIONAL ALIGNMENT ITEMS IN RELATIONSHIP TO THE BUILDING TO SITE RELATED HORIZONTAL CONTROL. K. SIGNAGE BY OTHERS, TO BE PERMITTED BY OTHERS. PROVIDE ELECTRICAL AS REQUIRED. L. ALL EXPOSED METAL PLATES AND EXPOSED FLASHING ARE TO BE PAINTED TO MATCH ADJACENT BUILDING COLOR, UNLESS NOTED OTHERWISE. M. ALL SITE EQUIPMENT SHALL BE PAINTED TO MATCH ADJACENT BUILDING, SITE WALL, ETC. N. WHEN TWO DISSIMILAR MATERIALS ABUT, JOINT SEALANT TO BE COLOR MATCHED TO THE MATERIAL IN THE SAME PLANE AS THE SEALANT. O. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) TO BE FREE OF DEFECTS, STAMPS, MARKS AND IMPERFECTIONS. P. ALL EXPOSED WELDS TO BE CONTINUOUS OR OF EQUAL LENGTH AND SPACING. BONDO FILLER MAY BE REQUIRED TO MIMIC WELDS AT SOME LOCATIONS. Q. SPLICING OF EXPOSED STEEL ELEMENTS, IF NECESSARY, TO BE CONTINUOUS AND GROUND SMOOTH All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by the design professional as instruments of service shall remain the property of the design professional. The design professional shall retain all common law, statutory and other reserved rights, including the copyright thereto. OWNERSHIP OF INSTRUMENTS OF SERVICE PRELIMINARY NOT FOR CONSTRUCTION 602-957-1800 Phoenix, Arizona 85034 5017 East Washington St. #107 architects & planners Phone Butler Design Group Inc. Revisions: Title: Drawn By: Project Number: Date: Case #: Plan Check #: Submittal: AC301 BLDG C - EXTERIOR ELEVATIONS 22025 10/10/2022 LUKE FIELD BUILDINGS A, B & C MARICOPA COUNTY MILITARY COMPATIBILITY # X MATERIAL / COLOR SCHEDULE # ELEVATION KEYNOTES SCALE: 1" = 80'-0" 1 BLDG C - NORTH ELEVATION SCALE: 1" = 40'-0" 4 BLDG C - EAST ELEVATION SCALE: 1" = 40'-0" 2 BLDG C - ENLARGED NORTH ELEVATION SCALE: 1" = 40'-0" 3 BLDG C - ENLARGED NORTH ELEVATION MARK DESCRIPTION FINISH/COLOR MODEL MANUFACTURER COMMENTS GLAZING GL1 1" INSULATED GLAZING TINTED BLUE - - - MASONRY MU1 8x8x16 CONCRETE MASONRY UNITS PEBBLE BEACH TRENDSTONE ECHELON MASONRY - PAINT FF1 FACTORY FINISH O.H.D. (WHITE) MANUFACTURER FINISH - - - PT1 CONC. TILT PANEL - PAINTED FOSSIL DE6365 DUNN EDWARDS - PT2 CONC. TILT PANEL - PAINTED WALRUS DE6368 DUNN EDWARDS - PT3 CONC. TILT PANEL - PAINTED SO CHIC! DET614 DUNN EDWARDS - PT4 CONC. TILT PANEL - PAINTED CHARCOAL SMUDGE DE6370 DUNN EDWARDS - PT5 CONC. TILT PANEL - PAINTED BLACK TIE DE6357 DUNN EDWARDS - 0308 PAINTED CONCRETE TILT-PANEL - TYP. 0318 CONCRETE TILT PANEL KNOCKOUT 0506 PAINTED STEEL CANOPY - SEE REFLECTED CANOPY/CEILING PLANS 0703 DASHED LINE OF ROOF, AND FUTURE MECHANICAL UNITS BEYOND. MECHANICAL UNITS TO BE FULLY SCREENED FROM VIEW 0801 ALUMINUM STOREFRONT SYSTEM - SEE WINDOW TYPES 0802 HOLLOW METAL DOOR - PAINTED. SEE ELEVATIONS FOR FINISH INFORMATION. 0803 FACTORY FINISHED 9'X10' OVERHEAD SECTIONAL DOOR. SEE DOOR TYPES. 0804 FACTORY FINISHED 12'X14' OVERHEAD SECTIONAL DOOR. SEE DOOR TYPES. 0805 ALUMINUM FRAMED WINDOW - SEE WINDOW TYPES. 2201 SCUPPER BOX AND DOWN SPOUT - SEE ELEVATIONS 2601 WALL PACK LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS 2602 TRANSFORMER 2603 SERVICE ENTRANCE SECTION ON CONCRETE PAD. PAINT TO MATCH BUILDING PAINT COLOR. SEE ELECTRICAL DWGS. C B A D E F G H I J K L M N F.F. 0" T.O.P. 51' - 0" T.O.P. 55' - 0" T.O.P. 51' - 0" F.F. 0" PT3 PT1 PT2 PT1 PT4 PT1 PT2 PT3 GL1 TYP 0703 TYP 0805 TYP 0308 0506 TYP 2601 0508 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 / 3 AC302 / 2 AC302 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 / 3 AC302 T.O.P. 50' - 0" DOCK -4' - 0" T.O.P. 48' - 0" T.O.P. 50' - 0" T.O.P. 49' - 0" F.F. 0" PT1 PT2 PT2 FF1 PT1 GL1 PT2 PT4 PT3 PT2 PT2 PT4 PT2 PT1 TYP 0804 TYP 0803 TYP 0802 TYP 0703 TYP 0308 TYP 2202 TYP 2601 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 / 2 AC302 T.O.P. 50' - 0" F.F. 0" T.O.P. 48' - 0" T.O.P. 50' - 0" DOCK -4' - 0" T.O.P. 50' - 0" PT1 PT3 PT1 PT2 GL1 FF1 PT2 PT4 PT2 PT1 PT2 GL1 PT3 TYP 0803 TYP 2601 TYP 0802 TYP 0308 TYP 0703 TYP 2201 TYP 0805 TYP 0804 GENERAL ELEVATION NOTES A. SEE ENLARGED ELEVATIONS, DETAILS, AND WALL SECTIONS FOR ADDITIONAL INFORMATION IN RELATIONSHIP TO EXTERIOR CONDITIONS. B. GRADES AT PERIMETER OF BUILDING ARE TO BE COORDINATED WITH THE CIVIL DOCUMENTS FOR ACTUAL FINISH GRADE LOCATIONS. C. TOP OF PARAPET IS BASED ON ELEVATIONS ABOVE FINISHED FLOOR. D. SEE DOOR AND WINDOW SCHEDULES AND ELEVATIONS FOR ADDITIONAL INFORMATION IN RELATIONSHIP TO TYPE AND STYLE. E. ALL DIMENSIONS SHOWN FOR LOCATIONS OF FINISH OF EXTERIOR ELEMENTS ARE TO BE COORDINATED WITH ARCHITECTURAL FLOOR PLANS, DETAILS, AND SECTIONS. F. REFER TO WINDOW TYPES FOR TEMPERED GLASS LOCATIONS. G. PAINT TRANSITIONS ARE TO BE COORDINATED WITH THE ARCHITECT PRIOR TO APPLICATION. H. SEE ELECTRICAL DOCUMENTS FOR EXTERIOR LIGHTING FIXTURES, THE LOCATIONS SHOWN ON THE EXTERIOR ELEVATIONS AND WALL SECTIONS SHALL BE USED AT ALL LOCATIONS. I. PROVIDE BUILDING ADDRESS NUMBERS AT STREET SIDE OF BULDING AND OTHER LOCATIONS AS SHOWN ON THE EXTERIOR ELEVATIONS. NUMBERS SHALL BE A MINIMUM OF 12" HIGH REVERSED PAN CHANNEL IN CONTRASTING COLORS. J. SEE SITE PLAN AND HARDSCAPE PLANS FOR ADDITIONAL ALIGNMENT ITEMS IN RELATIONSHIP TO THE BUILDING TO SITE RELATED HORIZONTAL CONTROL. K. SIGNAGE BY OTHERS, TO BE PERMITTED BY OTHERS. PROVIDE ELECTRICAL AS REQUIRED. L. ALL EXPOSED METAL PLATES AND EXPOSED FLASHING ARE TO BE PAINTED TO MATCH ADJACENT BUILDING COLOR, UNLESS NOTED OTHERWISE. M. ALL SITE EQUIPMENT SHALL BE PAINTED TO MATCH ADJACENT BUILDING, SITE WALL, ETC. N. WHEN TWO DISSIMILAR MATERIALS ABUT, JOINT SEALANT TO BE COLOR MATCHED TO THE MATERIAL IN THE SAME PLANE AS THE SEALANT. O. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) TO BE FREE OF DEFECTS, STAMPS, MARKS AND IMPERFECTIONS. P. ALL EXPOSED WELDS TO BE CONTINUOUS OR OF EQUAL LENGTH AND SPACING. BONDO FILLER MAY BE REQUIRED TO MIMIC WELDS AT SOME LOCATIONS. Q. SPLICING OF EXPOSED STEEL ELEMENTS, IF NECESSARY, TO BE CONTINUOUS AND GROUND SMOOTH All reports, plans, specifications, computer files, field data, notes and other documents and instruments prepared by the design professional as instruments of service shall remain the property of the design professional. The design professional shall retain all common law, statutory and other reserved rights, including the copyright thereto. OWNERSHIP OF INSTRUMENTS OF SERVICE PRELIMINARY NOT FOR CONSTRUCTION 602-957-1800 Phoenix, Arizona 85034 5017 East Washington St. #107 architects & planners Phone Butler Design Group Inc. Revisions: Title: Drawn By: Project Number: Date: Case #: Plan Check #: Submittal: AC302 BLDG C - EXTERIOR ELEVATIONS 22025 10/10/2022 LUKE FIELD BUILDINGS A, B & C MARICOPA COUNTY MILITARY COMPATIBILITY # X MATERIAL / COLOR SCHEDULE # ELEVATION KEYNOTES SCALE: 1" = 40'-0" 4 BLDG C - WEST ELEVATION SCALE: 1" = 80'-0" 1 BLDG C - SOUTH ELEVATION SCALE: 1" = 40'-0" 2 BLDG C - ENLARGED SOUTH ELEVATION SCALE: 1" = 40'-0" 3 BLDG C - ENLARGED SOUTH ELEVATION MARK DESCRIPTION FINISH/COLOR MODEL MANUFACTURER COMMENTS GLAZING GL1 1" INSULATED GLAZING TINTED BLUE - - - MASONRY MU1 8x8x16 CONCRETE MASONRY UNITS PEBBLE BEACH TRENDSTONE ECHELON MASONRY - PAINT FF1 FACTORY FINISH O.H.D. (WHITE) MANUFACTURER FINISH - - - PT1 CONC. TILT PANEL - PAINTED FOSSIL DE6365 DUNN EDWARDS - PT2 CONC. TILT PANEL - PAINTED WALRUS DE6368 DUNN EDWARDS - PT3 CONC. TILT PANEL - PAINTED SO CHIC! DET614 DUNN EDWARDS - PT4 CONC. TILT PANEL - PAINTED CHARCOAL SMUDGE DE6370 DUNN EDWARDS - PT5 CONC. TILT PANEL - PAINTED BLACK TIE DE6357 DUNN EDWARDS - 0308 PAINTED CONCRETE TILT-PANEL - TYP. 0506 PAINTED STEEL CANOPY - SEE REFLECTED CANOPY/CEILING PLANS 0508 ALTERNATIVE ADDITION FOR THE ENTRY CANOPY 0703 DASHED LINE OF ROOF, AND FUTURE MECHANICAL UNITS BEYOND. MECHANICAL UNITS TO BE FULLY SCREENED FROM VIEW 0802 HOLLOW METAL DOOR - PAINTED. SEE ELEVATIONS FOR FINISH INFORMATION. 0803 FACTORY FINISHED 9'X10' OVERHEAD SECTIONAL DOOR. SEE DOOR TYPES. 0804 FACTORY FINISHED 12'X14' OVERHEAD SECTIONAL DOOR. SEE DOOR TYPES. 0805 ALUMINUM FRAMED WINDOW - SEE WINDOW TYPES. 2201 SCUPPER BOX AND DOWN SPOUT - SEE ELEVATIONS 2202 ROOF DRAIN AND OVERFLOW - SEE PLUMBING DRAWINGS 2601 WALL PACK LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS w w w w w w W. NORTHERN AVENUE N. LITCHFIELD ROAD NORTH QUARTER CORNER SECTION 3, T2N, R1W NORTHWEST CORNER SECTION 3, T2N, R1W WEST QUARTER CORNER SECTION 3, T2N, R1W S2°04'48"E 2621.1' N89°12'48" W 2629.0' N89°01'37"W 2625.0' SHEET 4 SHEET 3 SHEET 2 SHEET 5 SHEET 6 SHEET 7 BUILDING A BUILDING B BUILDING C N2°10'35"W 2612.8' Designer: Drawn by: Project: Sheet No. Job No. Call at least two full working days before you begin excavation. Dial 8-1-1 or 1-800-STAKE-IT (782-5348) In Maricopa County: (602)263-1100 w w w . e p s g r o u p i n c . c o m T:480.503.2250 F:480.503.2258 | 1130 N Alma School Road Suite 120 Mesa, AZ 85201 22-0186 - Luke Field Preliminary Utilities Plans Luke Field Glendale, Arizona DBA DBA 22-0186 of 7 CASE # MCP2022007 CS01 LUKE FIELD PRELIMINARY UTILITIES PLANS FOR DESCRIPTION SHEET NO COVER SHEET CS01 1 PRELIMINARY UTILITIES PLANS UT01 - UT06 2 - 7 KEY MAP SCALE 1" = 200': 1 Cover Sheet A PORTION OF THE NORTHWEST QUARTER OF SECTION 3, TOWNSHIP 2 NORTH, RANGE 1 WEST, OF THE GILA AND SALT RIVER MERIDIAN, MARICOPA COUNTY, ARIZONA CIVIL ENGINEER: EPS GROUP, INC. 1130 N. ALMA SCHOOL RD, STE 120 MESA, ARIZONA 85201 PHONE: (480) 503-2250 FAX: (480) 503-2258 CONTACT: DAN "OX" AUXIER, P.E. EMAIL: dan.auxier@epsgroupinc.com OWNER/DEVELOPER: LINCOLN PROPERTY COMPANY 3131 E. CAMELBACK RD, STE 318 PHOENIX, AZ 85016 PHONE: (602) 541-0987 CONTACT: ANTHONY VILLARREAL EMAIL: avillarreal@lpc.com VICINITY MAP WEST GLENDALE AVENUE NORTH DYSART ROAD NORTH LITCHFIELD ROAD WEST NORTHERN AVENUE SITE SECTION 3 T.2 N., R.1 W. ARCHITECT: BUTLER DESIGN GROUP 5017 E. WASHINGTON ST, STE 107 PHOENIX, ARIZONA 85034 PHONE: (602) 957-1800 CONTACT: RICK BUTLER EMAIL: rbutler@butlerdesigngroup.com MARICOPA COUNTY, ARIZONA LEGEND PROPOSED STORM DRAIN LINE GRADE BREAK GRADE CHANGE DRYWELL PROPOSED VERTICAL CURB PROPOSED ROLL CURB PROPOSED CENTERLINE PROPOSED MULTI USE EASEMENT PROPOSED SIDEWALK RAMP PROPOSED SURVEY MONUMENT PROPOSED WATER SERVICE PROPOSED PRIVATE WATERLINE PROPOSED WATER VALVE PROPOSED SEWERLINE PROPOSED SEWER MANHOLE PROPOSED CATCH BASIN EXISTING TELEPHONE EXISTING OVERHEAD ELECTRIC EXISTING GAS EXISTING FIBER OPTIC EXISTING UNDERGROUND ELECTRIC EXISTING WATER EXISTING SEWER EXISTING STREET LIGHT EXISTING JUNCTION BOX EXISTING GUY WIRE EXISTING SEWER MANHOLE W EXISTING WATER METER EXISTING VERTICAL CURB EXISTING ROLL CURB EXISTING WATER VALVE PROPOSED FIRE HYDRANT EXISTING FIRE HYDRANT PROPOSED STREET SIGN EXISTING STREET SIGN PROPOSED SWALE ULTIMATE OUTFALL EXISTING CONTOUR PROPOSED CONTOUR DRAINAGE FLOW ARROW PROPOSED PRIVATE FIRELINE SL BENCHMARK: MARICOPA COUNTY OF TRANSPORTATION PRIMARY CONTROL POINT NO. 563, DESCRIBED AS MARICOPA COUNTY BRASS CAP FLUSH, STAMPED LIGHTNING, HAVING AN ELEVATION OF 1083.44' (NAVD88) THE BASIS OF BEARING IS THE NORTH LINE OF THE NORTHWEST QUARTER OF SECTION 3, TOWNSHIP 2 NORTH, RANGE 1 WEST GILA AND SALT RIVER MERIDIAN, MARICOPA COUNTY, ARIZONA. SAID BEARING BEING NORTH 89 DEGREES 12 MINUTES 48 SECONDS WEST, PER ALTA SURVEY OF NORTHERN PARKWAY AND DYSART ROAD, GLENDALE, PREPARED BY ALLIANCE LAND SURVEYING LLC, DATED 10-11-17, JOB NUMBER 171004, BY G. BRYAN GOETZENBERGER. BASIS OF BEARING FLOODPLAIN STATEMENT: THIS SITE IS LOCATED WITHIN FEMA FLOOD ZONE X AS SHOWN ON FEMA FLOOD INSURANCE RATE MAP 04013C3102M DATED NOVEMBER 4, 2015. FLOOD ZONE X IS DEFINED AS: AREAS OF 0.2% ANNUAL CHANCE FLOOD; AREAS OF 1% ANNUAL CHANCE FLOOD WITH AVERAGE DEPTHS OF LESS THAN ONE (1) FOOT OR WITH DRAINAGE AREAS LESS THAN ONE (1) SQUARE MILE; AND AREAS PROTECTED BY LEVEES FROM 1% ANNUAL CHANCE FLOOD. P P P P w w w w MATCH SHEET 4 SEW MANHOLE (TYP) 8" SEW 12" WAT PM 12" WAT 8" SEW 33.0' COUNTY ROAD, BOOK 3, PAGE 30 OF ROAD MAPS, M.C.R. 40.0' COUNTY ROAD, BOOK 10, PAGE 38 OF ROAD MAPS, M.C.R. 55.0' COUNTY ROAD, BOOK 30, PAGE 86 OF ROAD MAPS, M.C.R. 36.0' B/C 33.0' COUNTY ROAD, BOOK 3, PAGE 30 OF ROAD MAPS, M.C.R. 7.0' HIGHWAY EASEMENT DOCKET 2854, PAGE 536, M.C.R. 27.5'(VARIES) E/P TO E/P 40.5' EX E/P TO PL 20.0' BSL EXCEPTION PARCEL B APN: 501-52-003A SBA TOWERS X LLC DOCUMENT 2021-0518280, M.C.R. BUILDING A FF=84.00 NORTHWEST CORNER SECTION 3, T2N, R1W N89°12'48" W 2629.0' 6" DOM WAT FIRE HYDRANT (TYP) FIRE HYDRANT (TYP) 10" FIRE 8" SEW 12" PUBLIC WAT 10" FIRE 8" RAW WAT MATCH SHEET 3 55.0' R/W N. LITCHFIELD ROAD W. NORTHERN AVENUE 8.0' PUE 8.0' PUE FIRE HYDRANT (TYP) 65.0' R/W EXISTING WELL, PROTECT IN PLACE S89°12'48"E 195.26' S89°12'48"E 998.36' S2°10'35"E 15.02' S9°03'38"E 78.16' S0°49'37"W 22.00' N89°10'23"W 4.00' N89°10'23"W 31.00' S2°07'23"E 194.26' S89°10'23"E 362.00' 10" FIRE 4" SEW SVC 8.0' EX ELEC ESMT 6" DOM WAT SEW MANHOLE (TYP) 10" FIRE 6" DOM WAT 2" WAT (2) 2" WAT (2) 2" WATER SERVICE METER (2) 4" BACKFLOW PREVENTER (2) 2" WATER SERVICE METER (2) 4" BACKLOW PREVENTER (2) 6" DOM WAT Designer: Drawn by: Project: Sheet No. Job No. Call at least two full working days before you begin excavation. Dial 8-1-1 or 1-800-STAKE-IT (782-5348) In Maricopa County: (602)263-1100 w w w . e p s g r o u p i n c . c o m T:480.503.2250 F:480.503.2258 | 1130 N Alma School Road Suite 120 Mesa, AZ 85201 22-0186 - Luke Field Preliminary Utilities Plans Luke Field Glendale, Arizona DBA DBA 22-0186 of 7 CASE # MCP2022007 UT01 2 feet scale: 1" = 50' 100 50 0 50 Preliminary Utilities Plans w w MATCH SHEET 2 MATCH SHEET 5 SEW MANHOLE (TYP) 4" SEW SVC 8" SEW 12" WAT P P W. NORTHERN AVENUE 12" WAT 12" WAT BUILDING B 33.0' COUNTY ROAD, BOOK 3, PAGE 30 OF ROAD MAPS, M.C.R. 7.0' HIGHWAY EASEMENT DOCKET 2854, PAGE 536, M.C.R. 41.0' E/P TO PL EXCEPTION PARCEL B APN: 501-52-003A SBA TOWERS X LLC DOCUMENT 2021-0518280, M.C.R. FF=84.00 NORTH QUARTER CORNER SECTION 3, T2N, R1W S2°04'48"E 2621.1' 8" FIRE 8" RAW WAT FIRE HYDRANT (TYP) 10" FIRE 4" SEW SVC 4" DOM WAT 12" PUBLIC WATER LINE FIRE HYDRANT (TYP) EX FENCE PROPERTY LINE 2" WATER SERVICE METER 4" BACKFLOW PREVENTER REFER TO PROJECT 21-1329 NORTHERN & DYSART FOR CONTINUATION 105.0' COUNTY R/W DOCUMENT 2014-0390433, M.C.R. 65.0' R/W 8.0' PUE 8.2' 4" DOM WAT 8" WAT 2" DOM WAT 10" FIRE 2" DOM WAT 10" FIRE SEW CLEANOUT (TYP) SEW MANHOLE (TYP) FIRE HYDRANT (TYP) 2" WATER SERVICE METER 4" BACKFLOW PREVENTER 10" FIRE 10" FIRE Designer: Drawn by: Project: Sheet No. Job No. Call at least two full working days before you begin excavation. Dial 8-1-1 or 1-800-STAKE-IT (782-5348) In Maricopa County: (602)263-1100 w w w . e p s g r o u p i n c . c o m T:480.503.2250 F:480.503.2258 | 1130 N Alma School Road Suite 120 Mesa, AZ 85201 22-0186 - Luke Field Preliminary Utilities Plans Luke Field Glendale, Arizona DBA DBA 22-0186 of 7 CASE # MCP2022007 UT02 3 Preliminary Utilities Plans feet scale: 1" = 50' 100 50 0 50 MATCH SHEET 2 MATCH SHEET 5 MATCH SHEET 6 SEW MANHOLE (TYP) 8" SEW 8" SEW N. LITCHFIELD ROAD 10" FIRE 8" SEW FIRE HYDRANT (TYP) BUILDING C 33.0' COUNTY ROAD, BOOK 3, PAGE 30 OF ROAD MAPS, M.C.R. 40.0' COUNTY ROAD, BOOK 10, PAGE 38 OF ROAD MAPS, M.C.R. 55.0' COUNTY ROAD, BOOK 30, PAGE 86 OF ROAD MAPS, M.C.R. 23.0' E/P TO PL N2°10'35"W 2612.8' 10" FIRE 55.0' R/W 6" PET GAS 8.0' PUE FIRE HYDRANT (TYP) 8" SEW 8" SEW 10" FIRE 10" FIRE 4" SEW SVC 8" SEW 10" FIRE 8" FIRE 10" FIRE 10" FIRE SEW MANHOLE (TYP) 6" SEW SVC 6" SEW SVC 6" SEW SVC FF=83.00 FF=84.00 BUILDING A 6" PET GAS N2°10'35"W 2035.65' 6" WAT SEW MANHOLE (TYP) FIRE HYDRANT (TYP) Designer: Drawn by: Project: Sheet No. Job No. Call at least two full working days before you begin excavation. Dial 8-1-1 or 1-800-STAKE-IT (782-5348) In Maricopa County: (602)263-1100 w w w . e p s g r o u p i n c . c o m T:480.503.2250 F:480.503.2258 | 1130 N Alma School Road Suite 120 Mesa, AZ 85201 22-0186 - Luke Field Preliminary Utilities Plans Luke Field Glendale, Arizona DBA DBA 22-0186 of 7 CASE # MCP2022007 UT03 4 Preliminary Utilities Plans feet scale: 1" = 50' 100 50 0 50 X X X X X X X X X X X MATCH SHEET 3 MATCH SHEET 7 MATCH SHEET 4 SEW MANHOLE (TYP) 8" SEW 10" FIRE 5.0' S/B P P 8" SEW 8" SEW BUILDING C 105.0' COUNTY R/W DOCUMENT 2014-0390433, M.C.R. APN: 501-52-002D DESERT LEASING LLC DOCUMENT 2019-0791680, M.C.R. S2°04'48"E 2621.1' FF=83.00 10" FIRE 10" FIRE 10" FIRE FIRE HYDRANT (TYP) 10" FIRE 10" FIRE LINE 10" FIRE LINE 10" FIRE 2" DOM WAT 8" RAW WAT 2" DOM WAT 8" RAW WAT 500,000 GAL WAT TANK 500,000 GAL WAT TANK 10" FIRE 10" FIRE 10" FIRE FIRE HYDRANT (TYP) 8" SEW 8" SEW 6" SEW SVC 2" DOM WAT 10" FIRE 8" RAW WAT EX FENCE EX FENCE N2°04'48"W 2571.05' 6" SEW 6" SEW SEW CLEANOUT SEW CLEANOUT FF=84.00 BUILDING B SEW MANHOLE (TYP) 8" SEW BOOSTER PUMP STATION Designer: Drawn by: Project: Sheet No. Job No. Call at least two full working days before you begin excavation. Dial 8-1-1 or 1-800-STAKE-IT (782-5348) In Maricopa County: (602)263-1100 w w w . e p s g r o u p i n c . c o m T:480.503.2250 F:480.503.2258 | 1130 N Alma School Road Suite 120 Mesa, AZ 85201 22-0186 - Luke Field Preliminary Utilities Plans Luke Field Glendale, Arizona DBA DBA 22-0186 of 7 CASE # MCP2022007 UT04 5 Preliminary Utilities Plans feet scale: 1" = 50' 100 50 0 50 PETROLEUM GAS LINE CONNECTION MATCH SHEET 4 MATCH SHEET 7 8" SEW 10" FIRE FIRE HYDRANT (TYP) EXCEPTION PARCEL A APN: 501-52-006A UNITED STATES OF AMERICA DOCUMENT 00375-0146, M.C.R. P P P P 10" FIRE 10" FIRE 10" FIRE 6" PET GAS 4" SEW SVC N89°01'37"W 2625.0' EXISTING PETROLEUM GAS LINE TO BE REROUTED BY OTHERS PETROLEUM GAS LINE CONNECTION PROPERTY LINE PROPOSED PETROLEUM GAS LINE ESMT 6" PET GAS FF=83.00 BUILDING C WEST QUARTER CORNER SECTION 3, T2N, R1W N. LITCHFIELD ROAD N89°01'37"W 1423.34' S2°09'46"E 403.98' N87°50'14"E 1018.47' S36°23'58"E 224.98' WEST QUARTER CORNER SECTION 3, T2N, R1W 6" PET GAS SEW MANHOLE (TYP) 30.0' GAS ESMT 33.0' COUNTY ROAD, BOOK 3, PAGE 30 OF ROAD MAPS, M.C.R. 55.0' R/W 40.0' COUNTY ROAD, BOOK 10, PAGE 38 OF ROAD MAPS, M.C.R. 30.0' EX PIPELINE ESMT 30.0' GAS ESMT Designer: Drawn by: Project: Sheet No. Job No. Call at least two full working days before you begin excavation. Dial 8-1-1 or 1-800-STAKE-IT (782-5348) In Maricopa County: (602)263-1100 w w w . e p s g r o u p i n c . c o m T:480.503.2250 F:480.503.2258 | 1130 N Alma School Road Suite 120 Mesa, AZ 85201 22-0186 - Luke Field Preliminary Utilities Plans Luke Field Glendale, Arizona DBA DBA 22-0186 of 7 CASE # MCP2022007 UT05 6 Preliminary Utilities Plans feet scale: 1" = 50' 100 50 0 50 P P MATCH SHEET 6 MATCH SHEET 5 SEW MANHOLE (TYP) 8" SEW 30.0' EX GAS ESMT TO BE ABANDONED 10" FIRE FIRE HYDRANT (TYP) 105.0' COUNTY R/W DOCUMENT 2014-0390433, M.C.R. APN: 501-52-002D DESERT LEASING LLC DOCUMENT 2019-0791680, M.C.R. APN: 501-52-007 UNITED STATES OF AMERICA DOCUMENT NOD-00165, M.C.R. EXISTING PETROLEUM GAS LINE TO BE RELOCATED 30.0' GAS ESMT REFER TO PROJECT 21-1329 NORTHERN & DYSART FOR CONTINUATION 10" FIRE PROPOSED PETROLEUM GAS LINE ESMT 6" PET GAS 10" FIRE 10" FIRE FF=83.00 8.0' EX ELEC ESMT TO BE ABANDONED 30.0' PIPELINE ESMT BUILDING C S2°04'48"E 2621.1' N89°01'37"W 2625.0' N2°04'48"W 2571.05' N89°01'37"W 1423.34' SEW MANHOLE (TYP) Designer: Drawn by: Project: Sheet No. Job No. Call at least two full working days before you begin excavation. Dial 8-1-1 or 1-800-STAKE-IT (782-5348) In Maricopa County: (602)263-1100 w w w . e p s g r o u p i n c . c o m T:480.503.2250 F:480.503.2258 | 1130 N Alma School Road Suite 120 Mesa, AZ 85201 22-0186 - Luke Field Preliminary Utilities Plans Luke Field Glendale, Arizona DBA DBA 22-0186 of 7 CASE # MCP2022007 UT06 7 Preliminary Utilities Plans feet scale: 1" = 50' 100 50 0 50 Anh Harambasic, PE Planning & Development 301 W. Jefferson St., Suite 170 Phoenix, Arizona 85003 Phone: (602) 506-3611 www.maricopa.gov/planning email address: Anh.Harambasic@maricopa.gov Maricopa County Planning & Development Department Date: December 7, 2022 Memo To: Darren Gerard, AICP, Planning Manager, Department of Planning & Development Attn: Joel Landis, Planner, Planning & Development Services via: Bob Fedorka P.E., Engineering Supervisor, Planning and Development From: Anh Harambasic, PE, Plans Examiner Engineer, Planning & Development Subject: MCP2022007- Military Compatible Permit with Plan of Development - Luke Field Project. APN(s): 501-52-005J and 501-52-005H Summary- Request for MCP with POD to allow change from existing use from plant nursery to Warehouse distribution use. Located at the SEC of Northern and Litchfield Road. 137.6 acres. Engineering Review has reviewed the second plan (Revised plans via email sent 12.7.2022) and report routed for review on 12/7/2022, for the subject application and has no objections provided that any approvals include the following stipulations: The following general stipulations will apply: 1. Engineering review of planning and/or zoning cases is for conceptual design only. All development and engineering design shall be in conformance with Section 1205 of the Maricopa County Zoning Ordinance; Drainage Policies and Standards; Floodplain Regulations for Maricopa County; MCDOT Roadway Design Manual; and current engineering policies, standards and best practices at the time of application for construction. 2. Based on the conceptual design nature of the information submitted, changes to the site layout may be necessitated by the final engineering design of the site’s drainage infrastructure. 3. Detailed Grading and Drainage (Site Infrastructure) Plans must be submitted with the application for Building Permits 4. MCDOT ROW permits to be obtained during building permit phase. TIS APPROVED WITH MCDOT STIPULATIONS: 5. Upon TIS approval from the City of Glendale (COG) and Luke Air Force Base (LAFB), provide a copy of the authorization to MCDOT. Page 2 of 2 6. It is the developer’s responsibility to ensure annexation and right of way dedication to COG on Litchfield Road. 7. The future classification of Northern Avenue along the site frontage is recorded as Principal Arterial. MCDOT reduced the classification upon the first TIS review to the Urban Minor Arterial with no sidewalk. Half-street improvements shall be as per RDM Figure 5.9. 8. Half-street improvements and minimum of 55’ right of way dedication to MCDOT, apply to the entire frontage of Northern Avenue. Please contact me with any questions. DRAINAGE PLAN REVIEW REFERENCES: The Drainage Regulations are listed in Section 1205 of the MCZO: https://www.maricopa.gov/documentcenter/view/272 Maricopa County Drainage Policies and Standards Manual: https://www.maricopa.gov/DocumentCenter/Home/View/2369 For Additional Information See: https://www.maricopa.gov/1635/Drainage-Review FLOOD CONTROL DISTRICT OF MARICOPA COUNTY REFERENCES: Floodplain Regulations for Maricopa County: https://www.maricopa.gov/DocumentCenter/View/630 For Additional Information See: https://www.maricopa.gov/3847/Flood-Control-District PND TRANSPORTATION REFERENCES: Residential Driveway Guidelines https://www.maricopa.gov/documentcenter/view/362 Roadway Design Manual http://www.mcdot.maricopa.gov/DocumentCenter/View/24883 Maricopa County Resolution for ROW Permits https://www.maricopa.gov/documentcenter/view/364 For Additional Information See: https://www.maricopa.gov/156/MCDOT PND STORMWATER QUALITY (SWPPP) REFERENCES: Storm Water Quality Management and Discharge Control Regulation https://www.maricopa.gov/DocumentCenter/View/6577 Air Pollution Control Regulations Rule 310 https://www.maricopa.gov/DocumentCenter/View/5354 For Additional Information See: https://www.maricopa.gov/3980/Water-Sewage-Stormwater-Waste https://maricopacounty.sharepoint.com/sites/DOTTSMO/TSMO Traffic Development/MCP2022007 Luke Field TIS Review.docx MCDOT -- TRAFFIC ENGINEERING REVIEW COMMENT SHEET 1 of 1 Project Name: Luke Field Industrial Location: SEC Northern Ave and Litchfield Rd MCDOT File No.: MCP2022007 Date: 12/19/2022 Reviewer: Amber Cauble Phone No.: 602.319.0988 Consultant: EPS Group, Inc. Project No.: Plans Sealed By: Kelly S. Fletcher, P.E. Consultant Code: A = Will Comply B = Deleted C = Consultant to Evaluate Item Number Sheet Number Comments Consultant Reply = = = 1. 2. 3. = = = General General General 2nd REVIEW (TIS) Consultant: Please use the code and respond to each comment in the Consultant Reply Column. This sheet is for our record, please answer every question and sign and date your acknowledgement or the plans will be sent back to complete the process. Send back the marked-up plans and a new set of plans along with this comment sheet. Thank you for your cooperation. = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = General Project Summary: The proposed warehousing development is located at the southeast corner of Northern Avenue and Litchfield Road, in the City of Glendale (APN: 501-52- 005-J, 501-52-003-A, 501-52-005-H). The site proposes nine (9) driveways: five (5) new driveways on Litchfield Rd and four (4) full access driveways on Northern Ave. The TIS is based on an opening year of 2023 with a horizon year of 2028. Per the TIS, the trip generation is based on the ITE LUC code 150 – Warehousing with 2,321,420 SF building area. The proposed site is estimated to generate 3,970 total daily trips with 395 AM peak hour trips and 417 PM peak hour trips. General Comments: Upon TIS approval from the City of Glendale (COG) and Luke Air Force Base (LAFB), provide a copy of the authorization to MCDOT. It is the developer’s responsibility to ensure annexation and right of way dedication to COG on Litchfield Road. The future classification of Northern Avenue along the site frontage is recorded as Principal Arterial. Provide minimum of 55’ right of way dedication to MCDOT, along the site frontage of Northern Avenue. The Traffic Impact Study is Approved as indicated above. Signature: _____________________________________ Date: __________ Use CODE "A", "B","C" in this column next to every comment. = = = = SECOND REVISION __________ I:\TSM Traffic Development\1. Projects\North_West_Valley(North of I10_West of I17)\Luke Field_MCP2022007_Northern Ave and Litchfield Rd\1. Traffic Impact Studies\MCP2022007 Luke Field TIS 1st Review.docx MCDOT -- TRAFFIC ENGINEERING REVIEW COMMENT SHEET 1 of 1 Project Name: Luke Field Industrial Location: SEC Northern Ave and Litchfield Rd MCDOT File No.: MCP2022007 Date: 12/14/2022 Reviewer: Amber Cauble Phone No.: 602.319.0988 Consultant: EPS Group, Inc. Project No.: Plans Sealed By: Kelly S. Fletcher, P.E. Consultant Code: A = Will Comply B = Deleted C = Consultant to Evaluate Item Number Sheet Number Comments Consultant Reply = = = 1. 2. 3. 4. = = = General General General General 2nd REVIEW (TIS) Consultant: Please use the code and respond to each comment in the Consultant Reply Column. This sheet is for our record, please answer every question and sign and date your acknowledgment or the plans will be sent back to complete the process. Send back the marked-up plans and a new set of plans along with this comment sheet. Thank you for your cooperation. = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = General Project Summary: The proposed warehousing development is located at the southeast corner of Northern Avenue and Litchfield Road, in the City of Glendale (APN: 501-52- 005-J, 501-52-003-A, 501-52-005-H). The site proposes nine (9) driveways: five (5) new driveways on Litchfield Rd and four (4) full access driveways on Northern Ave. The TIS is based on an opening year of 2023 with a horizon year of 2028. Per the TIS, the trip generation is based on the ITE LUC code 150 – Warehousing with 2,321,420 SF building area. The proposed site is estimated to generate 3,970 total daily trips with 395 AM peak hour trips and 417 PM peak hour trips. General Comments: Upon TIS approval from the City of Glendale (COG) and Luke Air Force Base (LAFB), provide a copy of the authorization to MCDOT. It is the developer’s responsibility to ensure annexation and right of way dedication to COG on Litchfield Road. The future classification of Northern Avenue along the site frontage is recorded as Principal Arterial. MCDOT reduced the classification upon the first TIS review to the Urban Minor Arterial with sidewalk. Half-street improvements shall be as per RDM Figure 5.9. Half-street improvements and minimum of 55’ right of way dedication to MCDOT, apply to the entire frontage of Northern Avenue. The Traffic Impact Study is Approved as indicated above. Signature: _____________________________________ Date: ___________ Use CODE "A", "B","C" in this column next to every comment. = = = = Amended Project: Luke Field Industrial (SEC Northern Ave and Litchfield Rd) MCDOT File Number MCP2022007 Prepared by: EPS Group Date of Report: 8/23/2022 Reviewer: Amber Cauble, MCDOT Date of Review: 9/23/2022 # Reviewer: Review Comment: EPS Group Response: 1 MCDOT As Litchfield Road is under the City of Glendale’s (COG) jurisdiction, submit TIS to COG for review and approval. The traffic study has been submitted to Glendale. 2 MCDOT Due to the proximity of Luke Air Force Base (LAFB), submit TIS to LAFB for review and approval. Acknowledged. 3 MCDOT Following each agency approval, provide a copy of the authorization to MCDOT. The review comments below are limited to roadways in the project vicinity under Maricopa County jurisdiction. Acknowledged. 4 MCDOT Clarify the opening/buildout year and horizon year for the proposed development. Opening year is 2023. Build-out year is not known. 5 MCDOT Considering the proposed industrial land use, large size development, and upcoming heavy industrial facilities around SR 303, to be on conservative side, MCDOT requires the developer to use ITE land code 130 (Industrial Park) for estimating the trip generation for the proposed development. Please revise the TIS accordingly and resubmit. The scope of study has been approved by Glendale. The building is designed as Warehouse and doesn't meet the description for Industrial Park, since there will be only one user for each building. If the analysis was updated, the recommendations for Northern Avenue would not be affected. MCDOT only has jurisdiction for Northern Avenue as part of the study area for the TIA. Northern Avenue will end at the east end of the site and will not connect to the east in the future. Therefore, the only improvements inlcude the half-street improvements and right-turn deceleration lanes at the site driveways. Increasing the land use or background growth rate will not affect the improvements for Northern Avenue. 6 MCDOT Proposed access points on Northern Ave (A, B, C, and D) are conceptually acceptable to MCDOT. However, final determination will be made after the revised study is submitted to MCDOT addressing the comments in the current 1st review. Acknowledged. 7 MCDOT Due to the increasingly high development climate, MCDOT requires a minimum growth rate of 5% be used in future calculations. The scope of study has been approved by Glendale. MCDOT only has jurisdiction over Northern Avenue, which does not have existing traffic. The existing traffic is being replaced by the proposed development. Northern Avenue will end at the east end of the site and will not connect to the east in the future. Therefore, the only improvements relevant to MCDOT inlcude the half-street improvements for Northern Avenue and right-turn deceleration lanes at the site driveways. Increasing the land use or background growth rate will not affect the improvements for Northern Avenue. 1st Review Comments # Reviewer: Review Comment: EPS Group Response: 8 MCDOT Include traffic signal warrant, turn lane, LOS, and Queuing analysis at all proposed site driveways on Northern Ave, this shall be to the standards in the MCDOT Roadway Design Manual (RDM). LOS, turn lane, and queung analysis are already included in the report for the proposed site driveways on Northern Avenue. Signal warrant analyses are not necessary, since the ADT on Northern Avenue is only 1,192 vpd and the peak hour traffic existing the driveways is far below the thresholds. Northern Avenue ends at the east end of the site and will not continue east in the future. 9 MCDOT Provide right-turn deceleration lanes on Northern Ave at all site driveways, including Driveway A. Right-turn deceleration lanes were recommended at the truck driveways on Northern Avenue. Northern Avenue will end at east end of the site and not continue east in the future. MCDOT's right- turn criteria in the MCDOT Roadway Design Manual are not met for the installation of a right-turn deceleration lane at Driveway A. Driveway A will serve vehicle traffic only with a peak right-turn volume of 30 vph during the AM peak hour. However, less than 1,000 vpd are expected to use the driveway and less than 5,000 vpd are expected on Northern Avenue. 10 MCDOT Include and discuss sight distance at all proposed driveways in revised TIS, RDM 9.2.1. MCDOT's sight distance requirements have been added to the report. 11 MCDOT Half-street improvements along the site frontage of Northern Ave shall be to the Urban Minor Arterial section (RDM figure 5.9), w/o sidewalk. Added to report 12 MCDOT As part of half-street improvements, dedicate 55’ ROW to MCDOT along the site frontage of Northern Ave. Added to report I:\TSM Traffic Development\1. Projects\North_West_Valley(North of I10_West of I17)\Luke Field_MCP2022007_Northern Ave and Litchfield Rd\1. Traffic Impact Studies\MCP2022007 Luke Field TIS 1st Review.docx MCDOT -- TRAFFIC ENGINEERING REVIEW COMMENT SHEET 1 of 2 Project Name: Luke Field Industrial Location: SEC Northern Ave and Litchfield Rd MCDOT File No.: MCP2022007 Date: 09/23/2022 Reviewer: Amber Cauble Phone No.: 602.319.0988 Consultant: EPS Group, Inc. Project No.: Plans Sealed By: Kelly S. Fletcher, P.E. Consultant Code: A = Will Comply B = Deleted C = Consultant to Evaluate Item Number Sheet Number Comments Consultant Reply = = = 1. 2. 3. 4. = = = General General 3 11 1st REVIEW (TIS) Consultant: Please use the code and respond to each comment in the Consultant Reply Column. This sheet is for our record, please answer every question and sign and date your acknowledgement or the plans will be sent back to complete the process. Send back the marked-up plans and a new set of plans along with this comment sheet. Thank you for your cooperation. = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = General Project Summary: The proposed warehousing development is located at the southeast corner of Northern Avenue and Litchfield Road, in the City of Glendale (APN: 501-52- 005-J, 501-52-003-A, 501-52-005-H). The site proposes nine (9) driveways: five (5) new driveways on Litchfield Rd and four (4) full access driveways on Northern Ave. Per the TIS, the trip generation is based on the ITE LUC code 150 – Warehousing with 2,321,420 SF building area. The proposed site is estimated to generate 3,970 total daily trips with 395 AM peak hour trips and 417 PM peak hour trips. General Comments: As Litchfield Road is under the City of Glendale’s (COG) jurisdiction, submit TIS to COG for review and approval. Due to the proximity of Luke Air Force Base (LAFB), submit TIS to LAFB for review and approval. Following each agency approval, provide a copy of the authorization to MCDOT. The review comments below are limited to roadways in the project vicinity under Maricopa County jurisdiction. Review Comments: Clarify the opening/buildout year and horizon year for the proposed development. Considering the proposed industrial land use, large size development, and upcoming heavy industrial facilities around SR 303, to be on conservative side, MCDOT requires the developer to use ITE land code 130 (Industrial Park) for estimating the trip generation for the proposed development. Please revise the TIS accordingly and resubmit. Use CODE "A", "B","C" in this column next to every comment. = = = = I:\TSM Traffic Development\1. Projects\North_West_Valley(North of I10_West of I17)\Luke Field_MCP2022007_Northern Ave and Litchfield Rd\1. Traffic Impact Studies\MCP2022007 Luke Field TIS 1st Review.docx MCDOT -- TRAFFIC ENGINEERING REVIEW COMMENT SHEET 2 of 2 Project Name: Luke Field Industrial Location: SEC Northern Ave and Litchfield Rd MCDOT File No.: MCP2022007 Date: 09/23/2022 Reviewer: Amber Cauble Phone No.: 602.319.0988 Consultant: EPS Group, Inc. Project No.: Plans Sealed By: Kelly S. Fletcher, P.E. Consultant Code: A = Will Comply B = Deleted C = Consultant to Evaluate Item Number Sheet Number Comments Consultant Reply = = = 5. 6. 7. 8. 9. 10. 11. = = = 12 13 23 23 General General General 1st REVIEW (TIS) Consultant: Please use the code and respond to each comment in the Consultant Reply Column. This sheet is for our record, please answer every question and sign and date your acknowledgement or the plans will be sent back to complete the process. Send back the marked-up plans and a new set of plans along with this comment sheet. Thank you for your cooperation. = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = Proposed access points on Northern Ave (A, B, C, and D) are conceptually acceptable to MCDOT. However, final determination will be made after the revised study is submitted to MCDOT addressing the comments in the current 1st review. Due to the increasingly high development climate, MCDOT requires a minimum growth rate of 5% be used in future calculations. Include traffic signal warrant, turn lane, LOS, and Queuing analysis at all proposed site driveways on Northern Ave, this shall be to the standards in the MCDOT Roadway Design Manual (RDM). Provide right-turn deceleration lanes on Northern Ave at all site driveways, including Driveway A. Include and discuss sight distance at all proposed driveways in revised TIS, RDM 9.2.1. Half-street improvements along the site frontage of Northern Ave shall be to the Urban Minor Arterial section (RDM figure 5.9), w/o sidewalk. As part of half-street improvements, dedicate 55’ ROW to MCDOT along the site frontage of Northern Ave. The Traffic Impact Study is not approved. Signature: _____________________________________ Date: ___________ Use CODE "A", "B","C" in this column next to every comment. = = = = Subdivision, Infrastructure & Planning Program 1001 N. Central Avenue #150 Phoenix, Arizona 85004 Phone: (602) 506-1058 Fax: (602) 506-5813 TDD 602 506 6704 Maricopa County Environmental Services Department Water and Waste Management Division DATE: September 9, 2022 TO : Joel Landis, Planning & Development Dept. Planner FROM: Souren Naradikian, P.E. Senior Civil Engineer SUBJECT: MCP Luke Field. MCP2022007 The Maricopa County Environmental Services Department (MCESD) has reviewed documents received from the Maricopa County Planning and Development Department for the above referenced project. This project is a commercial site plan review at APN # 501-52-005H. Water and sewer will be provided by Valley Utilities for water/ Liberty Utilities for sewer. MCESD has concerns, ATC for water and sewer improvements must be obtained prior to construction permit approval. Based on the above, MCESD raised no objection to this project to the Planning & Development Department in Accela Automation on September 9, 2022, 2022 and the project may proceed at this time subject to the following stipulations: Condition: None. It should be noted that this document does not approve the referenced project. Comments are provided only as advisory to Maricopa County Planning and Development Department to assist staff to prepare a staff report. Other Maricopa County agencies may have additional requirements. Final review and approval will be made through Planning and Development Department procedures. Applicant may need to submit separate applications to the Maricopa County Environmental Services Department for approval of proposed facilities regulated by the Department. Review of any such application will be based on regulations in force at the time of application. DEPARTMENT OF THE AIR FORCE AIR EDUCATION AND TRAINING COMMAND 21 September 2022 Mr. Christopher P. Toale Director, Community Initiatives Team 56th Fighter Wing 14185 West Falcon Street Luke AFB AZ 85309-1629 Mr. Joel Landis Planner, Maricopa County 501 North 44th Street, Suite 200 Phoenix, AZ 85008 Re: MCP2022007, Luke Field Commercial Warehouse Complex (APNs: 501-52-005J & 501-52-005H) Dear Mr. Landis Thank you for the opportunity to provide comments on the Military Compatibility Permit Application for the Luke Field Commercial Warehouse Complex Development. The proposed project will consist of three speculative light industrial buildings with a completed height of approximately 56 feet. The 137-acre site is located at the southeast corner of Litchfield Rd and Northern Ave in unincorporated Maricopa County, AZ. The parcel is located inside the Luke AFB 1988 JLUS 80, 75 and 70 DNL “high noise or accident potential zone” as identified by A.R.S. §28-8461. Additionally, there are 7.33 acres of the northwest corner that are located inside the LAFB Clear Zone and Accident Potential Zone 1, also identified by A.R.S. §28-8461. While we recognize that Arizona law may not have restrictions in line with our concerns in this particular area of development, we continually appreciate the opportunity to provide comments, acknowledging that we are not the approval authority. Given the location of this development project, we have identified actual and/or potential mission risks and hazards should development encompass the following: a. Retention ponds or other features that would attract wildlife – Birds pose an aircraft strike hazard and are incompatible with flying operations. b. Light interference – Buildings or structures that would produce light interference at night and or glint/glare during the day that would distract or interfere with pilot vision. c. Spectrum utilization and radio frequency interference – Buildings or structures that would cause a loss of RADAR coverage such that it interferes with spectrum utilization. The area in which this development is proposed must contain an airspace analysis to ensure any buildings do not interfere with Luke's radar. Additionally, to avoid radio frequency interference, developers and or end users should not use radio equipment that would interfere with Luke’s frequency or operate on a military frequency. d. Physical Encroachment – Personnel standing on the top of the buildings could potentially surveille base activities. Cameras placed on top of building structures present a potential danger to military operations. When the time comes, Luke Security Forces personnel can provide a list of National Defense Authorization Act (NDAA) compliant security/surveillance equipment that would work best for our operations. e. Impairment of pilot’s visibility – Any production that would release substances into the air that would impair visibility or otherwise interfere with operating aircraft such as: steam, dust or smoke. These items create a negative impact and should be eliminated. f. Foreign persons involvement – given the location and sensitive nature of Luke’s mission, we ask that if the development involves transactions involving foreign investment or the leasing to foreign persons, that Luke AFB be notified immediately in order to determine the effect of such transactions on the national security of the United States. There are perpetual and assignable easements purchased by the United States for the benefit of Luke AFB located on the 7.33 acres of the northeast corner that Luke AFB must enforce (attached). Along with other language, the easement and rights granted consist of prohibiting future construction of buildings, structures or materials that infringe upon, extend into or above the Approach and/or Transitional Surface. In short, the areas stated in each easement need to remain undeveloped so to protect the airfield surface areas of Luke AFB. Based on the current conceptual site plan (attached), it is evident that the developer has eliminated all above grade development inside the clearance easement, “no build” area. Luke AFB follows A.R.S. § 28-8481 when evaluating compatible land use within the “territory in the vicinity of a military airport. Subject to the results of an FAA Obstruction Evaluation/Airport Airspace Analysis (OE/AAA), this request, as described in the narrative, will not negatively impact the flying and base operations at Luke AFB. Since the development will be located within the “territory in the vicinity of a military airport,” it will be subjected to approximately 165 over flights a day. In addition, a strong notification program on the part of the applicant is essential to inform potential occupants about Luke AFB operations. We also recommend that the developer and/or future occupants be made aware that the proposed development is underneath Luke AFB’s flight traffic pattern, specifically low-level flights; therefore, there is an increased risk of accidents in that area as well as fuel dumping or jettison of external aircraft tanks. If you have any questions, please contact my Community Planner, Mr. Mark James at (623) 856-9981. Sincerely CHRISTOPHER P. TOALE Attachment: Easement, Track No. H807E-2, dated 22 September 2005 cc: Colonel Keagan L. McLeese, Vice Commander, 56th Fighter Wing Mr. Timothy A. Forero, GS-13, General Law Attorney, 56th Fighter Wing TOALE.CHRISTOP HER.P.1039696165 Digitally signed by TOALE.CHRISTOPHER.P.10396 96165 Date: 2022.09.21 15:14:22 -07'00'