April 10, 2024 Z2023017 Page 1 of 3 Report to the Board of Supervisors Prepared by the Maricopa County Planning and Development Department Board Hearing Date: April 10, 2024 Case #/Title: Z2023017 - Ex El Pipeline Supervisor District: 1 Applicant/Owner: Brent Freeman, Freeman Custom Homes / Ex El Leasing Request: Zone change from C-3 & R-4 to C-3 CUPD with a Plan of Development Site Location: Generally located at the SWC of San Tan Blvd. & Mandarin Dr. in the Chandler Heights area Site Size: Approximately 2 acres (87,124 Sq. Ft.) County Island Status: N/A Additional Comments: There are no outstanding concerns from reviewing agencies. Staff notes the parcel is already mostly zoned C-3. This application is to bring the property under unified zoning. The CUPD overlay will liberalize development standards for flexibility in site design and redevelopment. The plan of development is for redevelopment to a plumbing supply and pipeline repair dispatch facility. There is no known opposition. April 10, 2024 Z2023017 Page 2 of 3 Commission Recommendation: On 3/7/24, the Commission voted 8-0 to adopt a motion recommending the Board of Supervisors approve Z2023017 subject to conditions ‘a’ – ‘i’: a. The area of APN 304-89-035Q & 30489035R is zoned C-3 CUPD with approval of Z2023017. b. A Plan of Development is approved subject to site plan entitled “EX EL LEASING SERVICES - ZONING CHANGE # Z2023017 – Site Plan” consisting of 1 full-size sheet, dated 9/25/23. The Plan of Development may be amended administratively under separate application as long as the amendment complies with the established CUPD development standards as approved by the Board of Supervisors. Staff may determine slight refinements to remain in substantial conformance with the approved site plan. Minor and major amendments to the site plan will be determined in accordance with Chapter 3 of the Maricopa County Zoning Ordinance. c. Development of the site shall be in substantial conformance with the narrative report entitled “EXEL Pipeline”, consisting of 5 pages, dated November 17, 2023, except as modified by the following conditions. d. The following IND-2 IUPD standards shall apply: 1. Parking requirement 1 space per 560 sq. ft. 2. Sight visibility triangle requirements – to match site plan SVT locations: 1. 25’X25X (Type1) 2. 25’X14’ (Type 2) e. The following engineering condition shall apply: 1. As part of half street improvements, maintain and provide a minimum of 40 feet of Right of Way Dedication to MCDOT along the entire site frontage of San Tan Blvd. a. Refer to the RED Letter- Right of way Dedication process. Applicant shall initiate ROW dedication and provide dedicated ROW prior to the issuance of a building permit. i. Right-of-Way Dedications | Maricopa County, AZ ii. Application- for-Right-of-Way-Dedication-PDF (maricopa.gov) 2. As part of half street improvements, Preserve 40 feet of future right of way along the site frontage of Mandarin Dr. 3. Further development on the property will require applicant to submit an updated TS/TIS specific to the proposed development. 4. Engineering review of planning and/or zoning cases is for conceptual design only. All development and engineering design shall be in conformance with Section 1205 of the Maricopa County Zoning Ordinance; Drainage Policies and Standards; Floodplain Regulations for Maricopa County; MCDOT Roadway Design Manual; and current engineering policies, standards and best practices at the time of application for construction. 5. Based on the conceptual design nature of the information submitted, changes to the site layout may be necessitated by the final engineering design of the site’s drainage infrastructure. April 10, 2024 Z2023017 Page 3 of 3 6. The proposed driveways will need to meet width requirements for heavy trucks. Additionally, driveway access via a MCDOT maintained roadway shall be installed per MCDOT requirements and MCDOT approved commercial driveway details. This will be addressed by P&D in the permitting and plan review stage. Only approved driveways are A). San Tan 185’ west of Mandarin Dr. and B). Mandarin 215’ south of San Tan Blvd. f. Prior to issuance of initial building permits, all parcels shall be combined to create a single parcel matching the zone change area. g. Prior to issuance of a building permit, written confirmation will be required from the emergency fire protection jurisdiction having authority that the facility has been designed in accordance with their regulations and requirements, and that emergency fire protection service will be provided to the facility. Prior to issuance of the certificate of occupancy, local fire protection jurisdiction review and approval will be required. h. The property owner/s and their successors waive claim for diminution in value if the County takes action to rescind approval due to noncompliance with conditions. i. The granting of this change in use of the property has been at the request of the applicant, with the consent of the landowner. The granting of this approval allows the property to enjoy uses in excess of those permitted by the zoning existing on the date of application, subject to conditions. Failure to comply with any condition may be grounds for consideration of initiating the process to revert the zoning back to the previous C-3, in accordance with Maricopa County requirements and procedures. Any action by Maricopa County to revert the zoning shall only occur following any and all required notices (including identification of the specific noncompliance issue) and cure periods and shall be subject to required public hearings before the Planning & Zoning Commission and Board of Supervisors, as set forth in the Maricopa County Zoning Ordinance. It is, therefore, stipulated and agreed that either revocation due to the failure to comply with any conditions, does not reduce any rights that existed on the date of application to use, divide, sell or possess the property and that there would be no diminution in value of the property from the value it held on the date of application due to such revocation of the zone change. The zone change enhances the value of the property above its value as of the date the zone change is granted and reverting to the prior zoning results in the same value of the property as if the zone change had never been granted. Presented by: Andrew Lorentzen, Planner Reviewed by: Darren Gérard, AICP, Planning Manager Attachment: 3/7/24 P&Z Packet (19 pages) Note: 3/7/24 Draft P&Z Minutes are not available as of the writing of this report, but can be provided upon request later when available. Z2023017 Page 1 of 8 Report to the Planning and Zoning Commission Prepared by the Maricopa County Planning and Development Department Case: Z2023017 - Ex El Pipeline Hearing Date: March 7, 2024 Supervisor District: 1 Applicant: Brent Freeman, Freeman Custom Homes Owner: Ex El Leasing Request: Zone change from C-3 & R-4 to C-3 CUPD with a Plan of Development Site Location: Generally located at the SWC of San Tan Blvd. & Mandarin Dr. in the Chandler Heights area Site Size: Approximately 2 acres (87,124 Sq. Ft.) Density: N/A County Island: No County Plan: Rural Development Area (0-1 d.u./ac) Municipal Plan: Town of Queen Creek – Rural Municipal Comments: None received to date Support/Opposition: None known Recommendation: Approve with conditions Z2023017 Page 2 of 8 Project Summary: 1. Brent Freeman with Freeman Custom Homes is requesting to change the zoning on a pair of parcels from C-3 & R-4 to C-3 CUPD for the development of a plumbing supply and pipeline repair dispatch facility. The majority of the parcels are zoned C-3 with only a 10-foot strip at the southern edge being separately zoned R-4. The current application proposes to unify the parcels under consistent C-3 CUPD zoning. 2. The parcels are currently undeveloped land with remaining orchard vegetation as evident in the aerial photos. The application is proposing to develop the site with a CUPD overlay to amend development standards for ease in site layout and functionality. The approximately 2-acre site is proposing a 7,200 sq ft. building comprised of a 1,500 sq. ft. office space and a 5,700 sq. ft. workspace/ inventory warehouse. The remaining outdoor space will be utilized as outdoor storage which will only be established behind 8-foot masonry walls which are proposed to surround the development. 3. The proposed site plan includes offsite improvements such as a paved right-turn lane into the development and paving and intersection improvements to Mandarin Dr. The facility will mainly be utilized by employees of the pipeline repair company with little estimated public customer visits. Proposed CUPD Deviations Z2023017 Page 3 of 8 Zoning Map Z2023017 Page 4 of 8 2023 Aerial Photo Proposed Site Plan 4. It should be noted that the applicant is proposing a site plan (POD) and although the zone change is a legislative approval, the POD will be administratively approved with zone change approval. Z2023017 Page 5 of 8 Existing On-Site and Adjacent Zoning / Land Use: 5. On-site: C-3 & R-4 / Vacant Land North: Rural-43 / Residential South: R-4 / Residential East: C-3 & R-4 / Residential West: C-3 & R-4 / Vacant land Utilities and Services: 6. Water: Chandler Heights Citrus Irrigation District Wastewater: Septic School District: Chandler Unified School District Fire: Queen Creek Fire Department Police: Queen Creek Police Department Right-of-Way: 7. The following table includes existing and proposed half-width right-of-way and the future classification based upon the Maricopa County Department of Transportation (MCDOT) Major Streets and Routes Plan. Street Name Half-width Existing R/W Half-width Proposed R/W Future Classification San Tan Blvd. 33’ 40’ Major Collector Mandarin Dr. 33’ 40’ Local Adopted Plans: 8. Vision 2030 Comprehensive Plan (adopted January 13, 2018): Property is designated for Rural Development Area (0-1 du. / ac.). 9. Town of Queen Creek 2018 General Plan (Updated January, 2024) The subject property is within the Town of Queen Creek’s planning area with a future use designation of ‘Rural’ which proposes a density of 1 dwelling unit per acre. Public Participation Summary: 10. The applicant sent notification letters to all parcels within 300’ of the subject parcel. The site has had 2 notification signs posted since 12/5/2023 and was updated with current public hearing information on 1/13/2024. To date, staff has not received any public support or opposition. Outstanding Concerns from Reviewing Agencies: 11. N/A Staff Analysis: 12. The applicant’s request to rezone a 10-foot strip of R-4 zoned land on the southern boundary of the property to align with the remaining existing C-3 zoning effectively is only 4% of the total site. Though undeveloped land, the site has existed as C-3 zoning since the zoning ordinance was implemented in 1969. It is staff’s assumption that the current parcel boundaries were intended to Z2023017 Page 6 of 8 follow the zoning boundary, such as is common in the area, though at some point an excess 10 feet was added to the parcel. Staff supports the zoning unification on the parcel and recognizes the applicant’s site plan layout which continues to leave the ‘R-4’ area free from any structures, pushing the site development away from the residences to the south. 13. Staff sees the use as appropriate for the location due to the limited proposed traffic and relatively minor daily impact the use will generate over other potential general commercial uses. Staff supports the CUPD overlay to amend the parking requirements as the proposed spaces (13) provide adequate parking for the provided office layout. Additionally, staff supports the proposed Plan of Development which include offsite roadway improvements to both San Tan Blvd. & Mandarin Dr. to further add to the improvement of the general area. Recommendation: 14. Staff recommends the Commission adopt a motion recommending that the Board of Supervisors approve Z2023017 subject to the following conditions ‘a’ – ‘i’: a. The area of APN 304-89-035Q & 30489035R is zoned C-3 CUPD with approval of Z2023017. b. A Plan of Development is approved subject to site plan entitled “EX EL LEASING SERVICES - ZONING CHANGE # Z2023017 – Site Plan” consisting of 1 full-size sheet, dated 9/25/23. The Plan of Development may be amended administratively under separate application as long as the amendment complies with the established CUPD development standards as approved by the Board of Supervisors. Staff may determine slight refinements to remain in substantial conformance with the approved site plan. Minor and major amendments to the site plan will be determined in accordance with Chapter 3 of the Maricopa County Zoning Ordinance. c. Development of the site shall be in substantial conformance with the narrative report entitled “EXEL Pipeline”, consisting of 5 pages, dated November 17, 2023, except as modified by the following conditions. d. The following IND-2 IUPD standards shall apply: 1. Parking requirement 1 space per 560 sq. ft. 2. Sight visibility triangle requirements – to match site plan SVT locations: 1. 25’X25X (Type1) 2. 25’X14’ (Type 2) e. The following engineering condition shall apply: 1. As part of half street improvements, maintain and provide a minimum of 40 feet of Right of Way Dedication to MCDOT along the entire site frontage of San Tan Blvd. a. Refer to the RED Letter- Right of way Dedication process. Applicant shall initiate ROW dedication and provide dedicated ROW prior to the issuance of a building permit. i. Right-of-Way Dedications | Maricopa County, AZ ii. Application- for-Right-of-Way-Dedication-PDF (maricopa.gov) 2. As part of half street improvements, Preserve 40 feet of future right of way along the site frontage of Mandarin Dr. 3. Further development on the property will require applicant to submit an updated Z2023017 Page 7 of 8 TS/TIS specific to the proposed development. 4. Engineering review of planning and/or zoning cases is for conceptual design only. All development and engineering design shall be in conformance with Section 1205 of the Maricopa County Zoning Ordinance; Drainage Policies and Standards; Floodplain Regulations for Maricopa County; MCDOT Roadway Design Manual; and current engineering policies, standards and best practices at the time of application for construction. 5. Based on the conceptual design nature of the information submitted, changes to the site layout may be necessitated by the final engineering design of the site’s drainage infrastructure. 6. The proposed driveways will need to meet width requirements for heavy trucks. Additionally, driveway access via a MCDOT maintained roadway shall be installed per MCDOT requirements and MCDOT approved commercial driveway details. This will be addressed by P&D in the permitting and plan review stage. Only approved driveways are A). San Tan 185’ west of Mandarin Dr. and B). Mandarin 215’ south of San Tan Blvd. f. Prior to issuance of initial building permits, all parcels shall be combined to create a single parcel matching the zone change area. g. Prior to issuance of a building permit, written confirmation will be required from the emergency fire protection jurisdiction having authority that the facility has been designed in accordance with their regulations and requirements, and that emergency fire protection service will be provided to the facility. Prior to issuance of the certificate of occupancy, local fire protection jurisdiction review and approval will be required. h. The property owner/s and their successors waive claim for diminution in value if the County takes action to rescind approval due to noncompliance with conditions. i. The granting of this change in use of the property has been at the request of the applicant, with the consent of the landowner. The granting of this approval allows the property to enjoy uses in excess of those permitted by the zoning existing on the date of application, subject to conditions. Failure to comply with any condition may be grounds for consideration of initiating the process to revert the zoning back to the previous C-3, in accordance with Maricopa County requirements and procedures. Any action by Maricopa County to revert the zoning shall only occur following any and all required notices (including identification of the specific noncompliance issue) and cure periods and shall be subject to required public hearings before the Planning & Zoning Commission and Board of Supervisors, as set forth in the Maricopa County Zoning Ordinance. It is, therefore, stipulated and agreed that either revocation due to the failure to comply with any conditions, does not reduce any rights that existed on the date of application to use, divide, sell or possess the property and that there would be no diminution in value of the property from the value it held on the date of application due to such revocation of the zone change. The zone change enhances the value of the property above its value as of the date the zone change is granted and reverting to the prior zoning results in the same value of the property as if the zone change had never been granted. Z2023017 Page 8 of 8 Presented by: Andrew Lorentzen, Planner Reviewed by: Matthew Holm, AICP, Planning Supervisor Attachments: Case Map (1 page) Site Plan (1 page) Narrative Report (5 pages) Engineering comments (2 pages) MCESD comments (2 pages) / Maricopa County Planning & Development - Phoenix, AZ 1 Gross Acres: 2 approx. Generated February 26, 2024 9:55 AM Z2023017 Application Name: Legal Description Ex El Pipeline EDR Applicant Case Address T02S R07E 031, T2S R07E 31 Brent Freeman for Freeman Custom Homes 18727 E SAN TAN Blvd Applicant Phone/Email Parcel Primary:304-89-035B 623.432.6312 brent@freemancustombuilds.com QUEEN CREEK AZ 85142 Map scale 1:995 Supervisor District No. 304-89-035C NEW METAL BUILDING WAREHOUSE/ OFFICE SPACE FOR PLUMBING SUPPLIES/ STORAGE SAN TAN BLVD MANDARIN RD 10' B.S.L 10' B.S.L 10' B.S.L 8' HIGH CMU BLOCK WALL EX. 8' HIGH CMU BLOCK WALL 8' HIGH CMU BLOCK WALL 304-89-035P GATE 25' 25' 25' 14' 8' HIGH CMU BLOCK WALL 215'-6" 404'-7 1/2" 215'-6" 404' 2-1/2" SIDEWALK STORAGE YARD CROSS HATCHED AREA IS NOT ZONED C-3, THIS IS THE AREA REQUESTING THE SPECIAL USE PERMIT ASPHALT APRON AT ROW TO REDUCE ROAD DEGRIDATION PAVEMENT ASPHALT DRIVE 8' HIGH CMU BLOCK WALL ASPHALT DRIVE EDGE OF PAVEMENT R.O.W. 40'-0" DIRT ROAD DIRT ROAD 8' HIGH CMU BLOCK WALL (E) TELEPHONE POLE INLET 10' B.S.L GATE SIDEWALK DECOMPOSED GRANITE (W/ LIQUID EMULISIFIER)LOT 11 10 09 08 NEW SEPTIC TANK AND SEEPAGE PITS 01 02 03 04 05 06 9'-0" 8.33% 8.33% DT 3 TYP. DT 5 TYP. BASIN 3 BASIN 4 BASIN 2 43'-11 1/2" 10'-0" 23'-10 1/2" 18'-0" 7'-0" ACCESSIBLE ROUTE TO R.O.W DRIVEWAY 30'-0" 10' B.S.L 25' 25' 25' 25' BASIN 1 40' - 0" 18'-0" 24'-0 1/2" 6'-0" 9'-0" 6'-1" 20'-0" 12'-10" 8' HIGH CMU BLOCK WALL 25'-5 1/2" ± 87,124 SQ FT OR ± 2.0 ACRES 6'-7" 7'-10 1/2" 7'-0 1/2" DT 1 TYP. DT 2 TYP. 25' B.S.L DECOMPOSED GRANITE (W/ LIQUID EMULISIFIER)LOT 6" HIGH CONC. CURB 25' 25' SVT - TYPE #1 SVT - TYPE #1 SVT - TYPE #2 SVT - TYPE #1 SVT - TYPE 1 12 6" W 6" W 6" W 6" W 6" W 6" W WATER LINE AND METER, SEE CIVIL PLANS APN 304-89-035F R.O.W. 40'-0" 10' B.S.L 25' B.S.L EX. 8' HIGH CMU BLOCK WALL APN 304-89-035H 07 13 30'-0" 18'-0" BASIN 5 BASIN 6 EX EL LEASING SERVICES- SPECIAL USE PERMIT Case #: Z2023017 & # B202302637 APN: 304-89-035P QUEEN CREEK, AZ 85142 VICINITY MAP BUILDING CODE DESIGN DATA - ALL CONSTRUCTION WITHIN MARICOPA COUNTY SHALL COMPLY WITH THE FOLLOWING CODES AND AMENDMENTS PER THEIR ADOPTED ORDINANCES: 2018 INTERNATIONAL BUILDING CODE 2018 INTERNATIONAL FIRE CODE 2018 INTERNATIONAL PLUMBING CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 INTERNATIONAL ENERGY CONSERVATION CODE 2018 INTERNATIONAL GREEN CONSTRUCTION CODE 2018 INTERNATIONAL FUEL GAS CODE 2017 NATIONAL ELECTRICAL CODE CURRENT MARICOPA COUNTY ZONING ORDINANCE DESIGN CRITERIA • GROUND SNOW LOAD = 0 • SITE CLASS = D • SEISMIC DESIGN CATEGORY = B • Ss = 0.16 S1 = 0.06 • SOIL BEARING CAPACITY = 1500 • WIND LOAD = 115 MPH BASIC WIND SPEED • WIND EXPOSURE = C THIS IS A REQUEST FOR A SPECIAL USE PERMIT FOR USE OF A PLUMBING COMPANY TO USE THE PROPERTY FOR THEIR BUSINESS WITH THE PROPERTY BEING DOUBLE ZONED AS A C-3 AND AN R-4 (APPROX. 10'-0" ALONG THE SOUTHERN PROPERTY LINE.) NEW CONSTRUCTION OF A PRE-FABRICCATED METAL BUILDING AND INTERIOR FIT OUT FOR FRONT OFFICE SPACE AND STORAGE FOR A PLUMBING SHOP. SCOPE OF WORK GENERAL CODE CLIENT: EX EL PIPELINE SERVICES, LLC 20567 S. 190TH STREET QUEEN CREEK, AZ 85142 ARCHITECT: KATHLEEN H BRAKEFIELD KHB ARCHITECTURE STUDIOS, PLLC 3867 E. PALMER STREET GILBERT, AZ 85298 PHONE:(707) 454-6513 EMAIL: HEATHER@KHBARCHSTUDIOS.COM CIVIL ENGINEER: WATSON CIVIL ENGINEERING JOEL WATSON PHONE: (480) 330-0803 EMAIL: JOEL@WATSONCIVILENGINEERING.COM CONTACT LIST ZONING CODE ANALYSIS PROJECT TYPE: ZONING CHANGE to CUPD SITE ACRAGE: 2.0 acres (+/- 87,124 SF) RIGHT OF WAY: 0.10 ACRES (+/- 4363 SF) SITE ACRAGE: GROSS AREA :2.0 acres (+/- 87,124 SF) NET AREA :1.9 acres (+/- 82,764 SF) SITE APN: 304-89-035P ZONING: C-3 (10'-0" ALONG THE SOUTHERN AREA OF THE PROPERTY IS ZONED R-4) MAIN BUILDING SETBACKS: (SEE SITE PLAN) • FRONT: 25'-0" • SIDE: 10'-0" • REAR: 25'-0" • STREET SIDE : 25'-0" • MAX. HEIGHT: 40'-0" • MIN. DISTANCE BTN BLDG: 25'-0" 1. OFFICE: 1,500 SF 2. PLUMBING SHOP: 5,700 SF TOTAL STRUCTURAL AREA: 7,200 SF / 87,153 SF (11.5% LOT COVERAGE OF TOTAL SITE AREA) FLOOD ZONE 'X' CUPD STANDARDS POWER RD N.SOSSAMAN RD HAWES RD HUNT HWY E. SAN TAN BLVD S. LIME RD S MANDARIN RD SITE LOCATION OPERATING HOURS. EVERY PROJECT IN ALL LIGHTING ZONES SHALL BE ENCOURAGED TO REDUCE AS MUCH AS POSSIBLE THE AMOUNT OF OUTDOOR LIGHTING THAT OPERATES AFTER 10:00 P.M., EXCEPT AS PERMITTED IN MCZO 1112.3.1. ALL NONSECURITY LIGHTING (EXCEPT FOR THE ILLUMINATION OF ROADWAYS AND STATE AND FEDERAL FLAGS) SHALL BE TURNED OFF BY 10:00 P.M. OR WITHIN ONE HOUR AFTER CLOSE-OF-BUSINESS, WHICHEVER IS LATER. A NIGHTTIME REDUCTION OF AT LEAST 50 PERCENT IN OVERALL LD OR LPD IS REQUIRED. ALL NON-FULL CUTOFF LUMINAIRES IN LIGHTING ZONES 1 AND 2 SHALL BE INCLUDED IN THE FIXTURES BEING TURNED OFF. ALL OUTDOOR LIGHTING WILL FACE AWAY FROM ADJACENT RESIDENCES AND WILL BE COMPLIANT WITH SECTION 1112 OF THE MARICOPA COUNTY ZONING ORDINANCE. POLE- OR WALL-MOUNTED LUMINAIRES SHALL BE FULL-CUTOFF LUMINAIRES ONLY. BOLLARDS SHALL BE FULL-CUTOFF, OR LOUVERED WITH COATED LAMPS. (SEE PCDSC 2.195.020, "BOLLARD, LOUVERED"). ALL LIGHT SOURCES SHALL HAVE A MAINTAINED COLOR TEMPERATURE OF LESS THAN OR EQUAL TO 3,000 DEGREES KELVIN. WALL-MOUNTED LUMINAIRES OF GREATER THAN 800 INITIAL LUMENS SHALL POSSESS A BOTTOM-DIFFUSING LENS OR AN INTERNAL HOUSE-SIDE SHIELD (HSS), TO THE SATISFACTION OF PLANNING STAFF, IN ORDER TO MINIMIZE THE ILLUMINANCE "HOT SPOT" ON THE WALL. UPLIGHTING LUMINAIRES SHALL NOT EXCEED 800 INITIAL LUMENS EACH. MOUNTING HEIGHT OF LUMINAIRES LOCATED AT OR WITHIN 30 FEET OF A RESIDENTIAL PROPERTY LINE SHALL NOT EXCEED EIGHT FEET IN HEIGHT. ALL OTHERS SHALL NOT EXCEED 15 FEET IN HEIGHT, AND THE POLE COLOR SHALL BE DARK AND NONREFLECTIVE (SUCH AS DARK BRONZE OR BLACK). PERIMETER (SPILL LIGHT) ILLUMINANCE LEVELS THE MAXIMUM INITIAL VERTICAL ILLUMINANCE AT ANY CALCULATION POINT SHALL NOT EXCEED 0.30 FOOTCANDLES DURING NORMAL BUSINESS EVENING HOURS, AND 0.10 FOOTCANDLES AFTER THE FACILITY ENTERS SECURITY LIGHTING-ONLY OPERATING MODE (IN COMPLIANCE WITH SUBSECTION (B) OF THIS SECTION). UPLIGHTING TO BE LESS THAN OR EQUAL TO 800 INITIAL LUMENS. TURN OFF TO BE AT 10:00 P.M. OR ONE HOUR AFTER CLOSE OF BUSINESS. LIGHTING REQUIREMENTS ABC AGGREGATE BASE COURSE A.F.F. ABOVE FINISHED FLOOR B.S.L. BUILDING SETBACK LINE C.M.U. CONCRETE MASONRY UNIT DW DISHWASHER F.O.P. FACE OF POST F.O.S. FACE OF STUD F.F. FINISHED FLOOR FG FIBER GLASS FLUOR. FLUORESCENT (FIXTURE) F.V. FIELD VERIFY GSM GALVANIZED SHEET METAL GFI GROUND FAULT CIRCUIT GYP. BD. GYPSUM BOARD I.B.C. INTERNATIONAL BUILDING CODE I.C.C. INTERNATIONAL CODE COUNCIL I.F.C. INTERNATIONAL FIRE CODE I.M.C. INTERNATIONAL MECHANICAL CODE I.P.C. INTERNATIONAL PLUMBING CODE I.R.C. INTERNATIONAL RESIDENTIAL CODE MFR. MANUFACTURER MICRO MICROWAVE OVEN N.E.C. NATIONAL ELECTRIC CODE N.T.S. NOT TO SCALE O.A. OVER ALL O.C. ON CENTER P.E.N. PERIMETER EDGE NAILING PTDF PRESSURE TREATED DOUGLAS FIR P.L.F. PER LINEAR FOOT REF REFRIGERATOR R RISER (ie 16R=16 RISERS) SPECS. SPECIFICATIONS SS STAINLESS STEEL TEMP. TEMPERED GLASS TC TRASH COMPACTOR TYP. TYPICAL U.O.N. UNLESS OTHERWISE NOTED WC WATER CLOSET WP WATER PROOF WI WROUGHT IRON WWF WELDED WIRE FABRIC ABBREVIATIONS SITE FENCES OR WALLS PARKING SIGHT VISIBILITY TRIANGLE PROPOSED CUPD STANDARDS 8'-0" MAX HEIGHT 13 SPACES (1 ADA= 5%) TYPE #1 - 25'-0" x 25'-0" TYPE #2 - 25'-0" x 14'-0" ARCHITECTURE | PLANNING | DESIGN Scale Project number Date Drawn by Checked by REV # DATE FOR: CONSTRUCTION DOCUMENTS © 2023 copyright KHB Architecture Studios, PLLC As indicated 12/5/2023 4:08:19 PM SP SITE PLAN 22119 Ex El LEASING SERVICES - ZONING CHANGE # Z2023017 9/25/23 KHB KHB Ex El LEASING SERVICES - ZONING CHANGE # Z2023017 18727 E. SAN TAN BLVD. QUEEN CREEK, AZ 85142 N O R T H 1" = 20'-0" SITE PLAN 20' 0' 5' 10' 40' 80' 12/05/23 NARRATIVE REPORT KHB ARCHITECTURE STUDIOS, PLLC heather@khbarchstudios.com (480) 687-3606 NOVEMBER 17, 2023 EXEL Pipeline Case # Z2023017 EX EL Pipeline Site Plan – Special Use Permit/ Rezone – case #Z2023017 1 | P a g e KHB Architecture Studios, PLLC Tel.480-687-3606 KHBarchstudios.com CONTENTS EXEL Pipeline ........................................................................................................................................ 0 Case # Z2023017 .................................................................................................................................. 0 PURPOSE OF REQUEST.................................................................................................................. 1 DESCRIPTION OF PROPOSAL ........................................................................................................ 1 SECTION 1 (PROPOSED BUILDING): ........................................................................................... 1 SECTION 2 (YARD): ...................................................................................................................... 2 DELIVERY ENTRANCES:.................................................................................................................. 2 ENVIRONMENTAL/NEIGHBORHOOD IMPACT: ............................................................................... 2 HOURS OF OPERATION/EMPLOYEES: ........................................................................................... 2 RELATIONSHIP TO SURROUNDING PROPERTIES ........................................................................ 2 LOCATION AND ACCESSIBILITY ..................................................................................................... 2 CIRCULATION SYSTEM ................................................................................................................... 3 DEVELOPMENT SCHEDULE ............................................................................................................ 3 COMMUNITY FACILITIES AND SERVICES ...................................................................................... 3 PUBLIC UTILITIES AND SERVICES ................................................................................................. 3 EX EL Pipeline Site Plan – Special Use Permit/ Rezone – case #Z2023017 1 | P a g e KHB Architecture Studios, PLLC Tel.480-687-3606 KHBarchstudios.com PURPOSE OF REQUEST According to Maricopa County Assessor's records, the Property size is approximately 2 acres (87,124 s.f.) for APN 304-89-035P. The parcel is currently vacant of any structures. Most of the Property is currently zoned C-3 (General Commercial), with a small portion along the southern property line (approximately 10-feet) currently zoned R-4 (Multiple Family Residential). The Property owners are seeking a special use permit to be able to use the property for a plumbing shop office and a storage for pipeline repair. The R-4 would like to be rezoned to meet the existing zoning of the entire property. We are requesting a rezone to a CUPD. Ex El Pipeline Services LLC is a plumbing contractor that has standing contracts with SRP, APS, and KinderMorgan to operate and maintain their natural gas pipeline facilities. We need offices for approximately 5 people daily, a meeting room for training and meeting purposes, a shop area to house our instruments and light equipment that is used for surveys and emergency response to leaks and other incidents. Portions of the shop will be used for storing long lead time items for regulator repair and other small parts such as gaskets, nuts and bolts, and pipe fittings. DESCRIPTION OF PROPOSAL Ex El Pipeline Services LLC proposes to build a 60' X 120' metal building on the 2 acres of property that we have acquired APN #'s 304-89-035P. The office/shop will be erected on the East side of the property and the entire 2 acres will have a masonry wall around the property (see drawing). SECTION 1 (PROPOSED BUILDING): The proposed building will be mostly a shop for the plumbing/ gas line services that Ex El provides. The building itself will be a pre-manufactured Steel building (to be designed by the manufacturer) The shop will consist of storage of various pipes, tools, and other items needed for various service calls. The building will be properly designed to store any materials or equipment considered hazardous. (Cleaning supplies, etc.) The other portion of the building will be the office area that will house the employees who work in the office during the day as well as an area for any customers that visit, which is very rare. EX EL Pipeline Site Plan – Special Use Permit/ Rezone – case #Z2023017 2 | P a g e KHB Architecture Studios, PLLC Tel.480-687-3606 KHBarchstudios.com SECTION 2 (YARD): The yard will be a place to store any service vehicles overnight and be an area to prepare and load or unload materials needed for service calls. Any materials stored here will be screened by an 8’-0” Concrete Block or brick wall, to be submitted as a separate permit. The yard will have entry from E. San Tan Blvd and exit at S. Mandarin Drive. The yard wants to be a permeable material to reduce greenhouse effects of asphalt paving. An approved dust control method will be utilized. The employee and customer parking lot areas will be paved with asphalt. Proposed CUPD Standards Site Fences or walls 8’-0” max height Parking 14 spaces (1 ADA = 5%) Sight Visibility Triangle Type #1 – 25’-0” x 25’-0” Type #2 – 25’-0” x 14’-0” DELIVERY ENTRANCES: There will be one delivery entrance. The truck will drive from E. San Tan Blvd onto the property into the yard and exits on S. Mandarin Drive. There will be a 2-yard refuse container in the yard for pick-up services related to the office. For larger potential needs, the business shall use rentals dumpster if ever required. The refuse will be located so that trucks can come into the yard and exit. ENVIRONMENTAL/NEIGHBORHOOD IMPACT: This property has a beautiful backdrop of San Tan Mountain and located at a centralized location for their service call regions. By being mindful of the residences across E. San Tan Blvd. HOURS OF OPERATION/EMPLOYEES: Our typical operating hours are from 7 AM to 4 PM, but as we are an emergency responder for some utilities, we will access the facility for instruments and parts when an emergency occurs. On rare occasions we may work in the office late to complete compliance reports to state and federal agencies. Typically, we will have 5 employees on site for short durations every day, we have 2 of the 5 employees on site every day with the other 3 making service calls on most days. We will have occasion for as many as 8 employees on site for training purposes, typically the training will last a few hours to possibly a full day. Customers rarely visit the shop as we usually meet on site where they are having the problems. RELATIONSHIP TO SURROUNDING PROPERTIES The office and fencing are intended to respect surrounding properties, since a lot of them are residential. The design will be basic and have smaller scale elements such as brick veneer for a variety of exterior materials. LOCATION AND ACCESSIBILITY The location of this property is in the Chandler Heights Citrus Community, along E. San Tan Blvd, at the Mandarin Drive intersection. There are a lot of commercial projects along this road and with its location between S. Power Rd. and S. Sossaman Rd., the location is close to residential areas. EX EL Pipeline Site Plan – Special Use Permit/ Rezone – case #Z2023017 3 | P a g e KHB Architecture Studios, PLLC Tel.480-687-3606 KHBarchstudios.com Although the site is not really intended to be a place for the public to visit, there will be accessible parking and access to the office area of the building. CIRCULATION SYSTEM The circulation system, as proposed if to have private access from E. San Tan Blvd with a drive aisle that will also connect on the South end of the property to S. Mandarin Drive. There will be two separate parking lots. One for employees (this will be located off S. Mandarin Drive and surrounded by 8’-0” block wall fencing. Parking will be provided on-site parking for employees and the occasional visitor. PROVIDED: 14 (1 ADA VAN SPACE) The yard will be used for material storage generally. Although, from time to time, work trucks may be parked in the yard overnight, behind the site fence. DEVELOPMENT SCHEDULE Once the application is submitted to Maricopa County, the owner will be sending out a letter to notify surrounding property owners of the intent for the Special Use Permit application as outlined in the Citizen Participation Plan. We anticipate that the application process will take roughly 4-6 months. The timeline for the building is roughly 20 weeks to erect the building and roughly 14 weeks to finish the interior. The rest of the site will be constructed concurrently. COMMUNITY FACILITIES AND SERVICES The Chandler Heights community is a beautiful rural area that has recently grown in its residential market. The backdrop surrounding the property is a view of San Tan Mountain and the surrounding foothills. The location is close enough to be included in the Queen Creek Police precincts that serve the area. They also have access to the Queen Creek Fire Department. The site Is easy to get to with access to Ellsworth loop that intersects with the 202 Loop. The community Is served by the Riggs Elementary school and the Willie & Coy Payne Junior High school (for both elementary and junior high school students) in the Chandler Unified School District. The nearest high school is Casteel High School. There Is a hospital, Banner Ironwood, that serves the area. PUBLIC UTILITIES AND SERVICES Water is served by Chandler Heights water district and electric by SRP. Trash services provided by waste management. Property will have a waste management dumpster this will sit behind an enclosure to screen. They will be Installing retention basins to control the storm water and keep as much as they can on the property. They will be installing a septic system that would accommodate waste. Planning & Development 301 W. Jefferson St., Suite 170 Phoenix, Arizona 85003 Maricopa.gov Anh Harambasic, PE Planning & Development Phone: (602) 506-3611 www.maricopa.gov/planning email address: Anh.Harambasic@maricopa.gov Maricopa County Planning & Development Department Date: January 5, 2023 Memo To: Darren Gerard, AICP, Planning Manager, Department of Planning & Development Attn: Andrew Lorentzen, Planner, Planning & Development Services cc: Bob Fedorka, PE, Engineering Supervisor, Planning and Development From: Anh Harambasic, PE, Plans Examiner Engineer, Planning & Development Subject: Z2023017 – EL Pipeline APN(s): 304-89-035Q and 304-89-035R Now 304-89-035P 18727 E San Tan Blvd Queen Creek, AZ . SEC Mandarin and San Tan Blvd. Summary- Current zoning C-3 and seeking zone change for southern 10’ from R-4 to C-3. From the narrative the property will be utilized for a plumbing warehouse with an office for approximately 5 people daily, shop area to house equipment and instruments. Engineering Review has reviewed the third submittal plan (Sealed 11.20.2023) and has no objections subject to the following conditions: 1. As part of half street improvements, maintain and provide a minimum of 40 feet of Right of Way Dedication to MCDOT along the entire site frontage of San Tan Blvd. a. Refer to the RED Letter- Right of way Dedication process. Applicant shall initiate ROW dedication and provide dedicated ROW prior to the issuance of a building permit. i. Right-of-Way Dedications | Maricopa County, AZ ii. Application-for-Right-of-Way-Dedication-PDF (maricopa.gov) 2. As part of half street improvements, Preserve 40 feet of future right of way along the site frontage of Mandarin Dr. 3. Further development on the property will require applicant to submit an updated TS/TIS specific to the proposed development. 4. Engineering review of planning and/or zoning cases is for conceptual design only. All development and engineering design shall be in conformance with Section 1205 of the Maricopa County Zoning Ordinance; Drainage Policies and Standards; Floodplain Regulations for Maricopa County; MCDOT Roadway Design Manual; and current engineering policies, standards and best practices at the time of application for construction. 5. Based on the conceptual design nature of the information submitted, changes to the site layout may be necessitated by the final engineering design of the site’s drainage infrastructure. Page 2 of 2 6. The proposed driveways will need to meet width requirements for heavy trucks. Additionally, driveway access via a MCDOT maintained roadway shall be installed per MCDOT requirements and MCDOT approved commercial driveway details. This will be addressed by P&D in the permitting and plan review stage. Only approved driveways are A). San Tan 185’ west of Mandarin Dr. and B). Mandarin 215’ south of San Tan Blvd. Please contact me with any questions. Page | 1 Maricopa County Environmental Services Department Water and Waste Management The Maricopa County Environmental Services Department (MCESD) has completed review for the New metal building warehouse/ office space for plumbing supplies/ storage planning case(s). Please note the following MCESD requirements for site development: Onsite Wastewater – A Notice of Intent to Discharge application for an onsite wastewater treatment (septic) system is required for any construction. Application must be submitted to the MCESD Onsite Wastewater Program. • Wastewater is not permitted to discharge to an adjacent parcel’s septic system. For Onsite Wastewater related questions, please contact the Onsite Program at (602) 506-6666 or by email at septicquestions@maricopa.gov Subdivision and Infrastructure – An Approval to Construct application is required and must be submitted to MCESD’s Subdivision & Infrastructure Program for water, reclaimed water and/or wastewater system infrastructure. A will serve letter issued by the Utility is required and must be submitted to MCESD’s Subdivision & Infrastructure Program if the site/development will be provided with water and/or reclaimed water by a Utility. A capacity assurance letter issued by the Utility is required to MCESD’s Subdivision & Infrastructure Program if the site/development wastewater service is being provided by a Utility. For subdivision related questions, please contact the Subdivision and Infrastructure Program at (602) 506-1058 or email subdivision@maricopa.gov. Additional Notes – Environmental Services does not require these items for condition of approval of Z2023017, however these items must be addressed with the development of the site. Environmental Services does not require additional review of this case. Project Name: New metal building warehouse/ office space for plumbing supplies/ storage Primary Contact Name: Brent Freeman Planning Application Type: Zone Change APN(s): 304-89-035C Reviewer: Souren Naradikian, P.E. Email: Souren.Naradikian@maricopa.gov Phone: 602-372-2907 Planner Name: Andrew Lorentzen Planning Case #: Z2023017 Date: February 10, 2023 Subdivision Infrastructure & Planning Program 301 W. Jefferson St. Phoenix, AZ 85003 Subdivision@maricopa.gov esd.maricopa.gov Page | 2 Maricopa County Environmental Services Department Water and Waste Management *It should be noted that this document does not approve the referenced project. Comments are provided for the benefit of the applicant for MCESD permit requirements and as an advisory to Maricopa County Planning and Development Department. Other Maricopa County agencies may have additional requirements. Final review and approval will be made through Planning and Development Department procedures. Applicant may need to submit separate applications to the Maricopa County Environmental Services Department for approval of proposed facilities regulated by the Department. Review of any such application will be based on current regulations at the time of application.